The safe relay output module provides 4 outputs and 8 solid state at 125mA (diagnostics) discrete outputs. It is designed to monitor safety actuators for relay outputs, with a rated supply voltage of 24V DC and a maximum power dissipation of 3W. It is furnished with spring clamp terminals, removable terminal block for electrical connection. It is an IP20 rated product. The safe relay modules type XPSMCMER0004 use guided contact safety relays, each of which provides two N.O. contacts and one N.C. contact in addition to the N.C. feedback contact. This safe relay output expansion module figures LEDs on its front face, displaying the status (power supply, run, internal or external errors, inputs status, restart signal, output channels). The safe relay output modules type XPSMCMER0002 and XPSMCMER0004 do not require the backplane expansion connectors as they are directly wired to the selected OSSD. It weighs 0.3kg. Its dimension are 22.5mm (Depth), 99mm (Height) and 114.5mm (Width). Its housing is red. It is powered with 24 VDC. It is ideal for monitoring safety functions such as emergency stop, guard monitoring, perimeter guarding, position monitoring, speed monitoring and enabling movement. The safe controller CPU Modicon MCM are certified by TüV SÃD meeting the industrial safety standards of Category 4, PL e according to EN/ISO 13849-1 and SILCL 3 according to IEC/EN 61508 and IEC/EN 60261. Compatible accessory for safe relay output module is a memory card. The module instals on Omega 35mm DIN rail conforming to EN 50022. The Modicon MCM modular safety controller system provide flexibility and scalability from 8 inputs, 2 dual/4 single channel outputs up to 128 inputs, 16 dual/32 single channel outputs, up to 32 or 48 diagnostic status outputs. Modicon MCM modular safety controller system are designed to monitor multiple safety functions on and around a machine to minimise the risk of people accessing the dangerous moving parts of the machine.
Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Preventa Safety automation |
| Product or Component Type | Safe relay output module |
| Device short name | XPSMCM |
| Electrical Connection | Spring terminal |
| [Us] rated supply voltage | 24 V - 20...20 % DC |
| Number of Outputs | 4 relay |
| Discrete output number | 8 solid state 125 mA diagnostics) |
| Function of module | Monitoring safety actuators relay output |
Complementary
| Characteristic | Value(s) |
|---|---|
| Maximum power dissipation in W | 3 W |
| Integrated connection type | Backplane expansion bus |
| Switching voltage | 10 V DC |
| Associated fuse rating | 3.5 A, slow-blow |
| Safety level | Can reach category 4 ISO 13849-1 Can reach PL = e ISO 13849-1 Can reach SIL 3 IEC 61508 SILCL 3 IEC 62061 |
| Quality labels | CE |
| Output type | Relay, 4 NO, volt-free |
| Quantity per Set | 1 |
| Switching time | 12 ms |
| Maximum switching voltage | 400 V AC 250 V DC |
| minimum switching current | 20 mA |
| Maximum switching current | 6 A |
| Number of terminal blocks | 4 |
| Local signalling | 1 LED green PWR power ON 1 LED green RUN RUN (status) 1 LED red E IN internal error 1 LED red E EX external error 2 LEDs orange ADDR node address 4 LEDs green/red RELAY K1...K4 relay contact 4 LEDs yellow RST reset |
| Connections - terminals | 1 spring clamp terminals, removable terminal block 2 spring clamp terminals, removable terminal block |
| Cable cross section | 0.0003â¦0.004 in² (0.2â¦2.5 mm²) - AWG 24...AWG 14 flexible without cable end 0.0004â¦0.004 in² (0.25â¦2.5 mm²) - AWG 23...AWG 14 flexible with cable end, with bezel 0.0004â¦0.004 in² (0.25â¦2.5 mm²) - AWG 23...AWG 14 flexible with cable end, without bezel 0.0003â¦0.004 in² (0.2â¦2.5 mm²) - AWG 24...AWG 14 solid without cable end 0.0008â¦0.002 in² (0.5â¦1 mm²) - AWG 20...AWG 18 flexible with cable end, with double bezel |
| Mounting support | Omega 35 mm DIN rail EN 50022 |
| Width | 0.9 in (22.5 mm) |
| Height | 3.9 in (99 mm) |
| Depth | 4.5 in (114.5 mm) |
| Product Weight | 0.7 lb(US) (0.3 kg) |

Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Preventa Safety automation |
| Product or Component Type | Preventa safety remote input module |
| Safety module name | XPSMF1 |
| Safety module application | Extension of I/O capacity |
| Safety use category | Category 4 maximum EN 954-1 Performance level e EN/ISO 13849-1 SIL 3 EN/IEC 61508 |
| Function of module | Monitoring safety detection discrete input Monitoring safety dialogue discrete input Monitoring short-circuit and line break remote line control output |
| [Us] Rated Supply Voltage | 24 V DC - 15...20 % |
| Supply | SELV or PELV EN/IEC 60950 |
| Discrete input number | 16 not isolated |
| Number of outputs | 4 not isolated line control outputs |
| Structure type | 10BASE-T/100BASE-TX |
Complementary
| Characteristic | Value(s) |
|---|---|
| Response Time | Depending on size of application |
| Voltage state 0 guaranteed | <= 5 V discrete input |
| Voltage state 1 guaranteed | >= 15 V discrete input |
| Current state 0 guaranteed | 1...1.5 mA discrete input) |
| Current state 1 guaranteed | >= 2 mA discrete input) |
| Discrete input voltage | 19.2 V |
| Discrete input current | 40 mA |
| Input protection type | Protected against short-circuit |
| Output voltage | 20 V line control outputs |
| Nominal output current | 60 mA line control outputs |
| Switching voltage | 7.5 V discrete input |
| Switching time | 250 µs discrete input |
| Communication port protocol | Safe Ethernet 2 RJ45 100 Mbps, 10 Mbps dual twisted pair cable, category 5D or better |
| Exchange mode | Half duplex, full duplex, autonegotiation |
| Number of terminal blocks | 1 discrete output 1 power supply 4 discrete input |
| Current consumption | 0.8 A 24 V DC on power supply |
| Mounting Support | 35 mm symmetrical DIN rail |
| Depth | 2.6 in (66.5 mm) |
| Height | 4.3 in (109 mm) |
| Width | 6.0 in (152 mm) |
| Product Weight | 1.5 lb(US) (0.7 kg) |

Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Preventa Safety automation |
| Product or Component Type | Preventa safety remote output relay module |
| Safety module name | XPSMF2 |
| Safety module application | Extension of I/O capacity |
| Safety use category | Category 4 maximum EN 954-1 Performance level e EN/ISO 13849-1 SIL 3 EN/IEC 61508 |
| Function of module | Monitoring safety actuators Monitoring safety dialogue |
| [Us] Rated Supply Voltage | 24 V DC - 15...20 % |
| Supply | SELV or PELV EN/IEC 60950 |
| Number of outputs | 8 relay |
| Structure type | 10BASE-T/100BASE-TX |
Complementary
| Characteristic | Value(s) |
|---|---|
| Response Time | Depending on size of application |
| Associated fuse rating | 10 A, slow-blow |
| Output type | Relay, 2 NO per output, volt-free |
| Minimum switching voltage | 5 V 250 V AC output relay 5 V 250 V DC output relay |
| Switching current capacity | 3 A / 100 A with internal fuse relay output |
| Maximum switching capacity in VA | <240 VA 0.5 relay output |
| Maximum switching capacity in W | <90 / 30 V relay output <30 / 127 V relay output <35 / 70 V relay output |
| Contacts material | Silver alloy (Ag/Ni) relay output |
| Electrical durability | 250000 cycles relay output |
| Mechanical durability | 1000000 cycles relay output |
| Communication port protocol | Safe Ethernet 2 RJ45 100 Mbps, 10 Mbps dual twisted pair cable, category 5D or better |
| Exchange mode | Half duplex, full duplex, autonegotiation |
| Number of terminal blocks | 1 power supply 8 relay output |
| Current consumption | 0.6 A 24 V DC on power supply |
| Mounting Support | 35 mm symmetrical DIN rail |
| Depth | 3.4 in (86.5 mm) |
| Height | 4.3 in (109 mm) |
| Width | 8.1 in (207 mm) |
| Product Weight | 2.9 lb(US) (1.3 kg) |

Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Preventa Safety automation |
| Product or Component Type | Preventa safety remote mixed I/O module |
| Safety module name | XPSMF3 |
| Safety module application | Extension of I/O capacity |
| Safety use category | Category 4 maximum EN 954-1 Performance level e EN/ISO 13849-1 SIL 3 EN/IEC 61508 |
| Structure type | 10BASE-T/100BASE-TX |
Complementary
| Characteristic | Value(s) |
|---|---|
| Function of module | Single-pole measuring of 0 to 10 V voltages Measuring, using shunt, 0/4 to 20 mA currents Closed circuit scanning of input channels |
| [Us] Rated Supply Voltage | 24 V DC - 15...20 % |
| Supply | SELV or PELV EN/IEC 60950 |
| Response Time | Depending on size of application |
| Analogue input number | 8 |
| Analogue Input Type | Not isolated |
| External resistance | 250 Ohm analogue input circuit 500 Ohm analogue input circuit |
| Analogue input range | 0...20 mA 500 Ohm 0...10 V |
| Input voltage limits | 0.1...11.5 V |
| Input current limits | 0.4â¦23 mA 500 Ohm |
| Analogue input resolution | 12 bits |
| Safety accuracy | +/- 2 % analogue input circuit |
| Maximum internal input resistance | 500 MOhm for signal source 2 Ohm |
| Input overvoltage protection | -4â¦15 V |
| Analogue output number | 4 |
| Analogue Output Type | Not isolated |
| Analogue output range | 4...20 mA |
| Output current limits | 0â¦20 mA |
| Analogue output resolution | 12 bits |
| Load impedance ohmic | <= 600 Ohm analogue output |
| Relative error | +/- 1 % |
| Maximum cable distance between devices | 11.8 in (300 mm) analogue input circuit 11.8 in (300 mm) analogue output |
| Communication port protocol | Safe Ethernet 2 RJ45 100 Mbps, 10 Mbps dual twisted pair cable, category 5D or better |
| Exchange mode | Half duplex, full duplex, autonegotiation |
| Number of terminal blocks | 1 power supply 5 analogue input/output circuit |
| Current consumption | 0.8 A 24 V DC on power supply |
| Mounting Support | 35 mm symmetrical DIN rail |
| Depth | 8.1 in (207 mm) |
| Height | 4.3 in (109 mm) |
| Width | 3.8 in (97.5 mm) |
| Product Weight | 2.09 lb(US) (0.95 kg) |

Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Preventa Safety automation |
| Product or Component Type | Preventa safety remote mixed I/O module |
| Safety module name | XPSMF3 |
| Safety module application | Extension of I/O capacity |
| Safety use category | Category 4 maximum EN 954-1 Performance level e EN/ISO 13849-1 SIL 3 EN/IEC 61508 |
| Function of module | Monitoring safety actuators discrete input Monitoring safety actuators discrete output Monitoring safety detection discrete input Monitoring safety dialogue discrete input Monitoring safety dialogue discrete output Monitoring short-circuit and line break line control outputs |
| [Us] Rated Supply Voltage | 24 V DC - 15...20 % |
| Supply | SELV or PELV EN/IEC 60950 |
| Discrete input number | 16 not isolated |
| Number of outputs | 2 not isolated line control outputs |
| Discrete output number | 16, not isolated |
| Structure type | 10BASE-T/100BASE-TX |
Complementary
| Characteristic | Value(s) |
|---|---|
| Response Time | Depending on size of application |
| Associated fuse rating | 16 A, slow-blow |
| Voltage state 0 guaranteed | <= 5 V discrete input |
| Voltage state 1 guaranteed | 15...< 30 V discrete input |
| Current state 0 guaranteed | 1...1.5 mA discrete input) |
| Current state 1 guaranteed | <= 2 mA discrete input) |
| Discrete input voltage | 20 V |
| Discrete input current | 40 mA |
| Input protection type | Protected against short-circuit |
| Output voltage | 20 V line control outputs |
| Nominal output current | 60 mA line control outputs |
| Switching voltage | 7.5 V discrete input |
| Switching time | 250 µs |
| Discrete output voltage | 24 V DC |
| Output voltage tolerance | +/- 3 % |
| Discrete output current | > 10 mA 140 °F (60 °C) channels 1 to 3, 5 to 7, 4 and 8) 1 A 140 °F (60 °C) channels 1 to 3, 5 to 7, 4 and 8) 2 A 104 °F (40 °C) channels 1 to 3, 5 to 7, 4 and 8) <= 9 A all channels) |
| Inductive load | 500 mH discrete output |
| Maximum tungsten load | <25 W discrete output |
| Maximum line resistance | 5 kOhm discrete output |
| Minimum load | 2 mA per channel |
| Maximum leakage current | 1 mA 2 V at state 0 discrete output |
| Communication port protocol | Safe Ethernet 2 RJ45 100 Mbps, 10 Mbps dual twisted pair cable, category 5D or better |
| Exchange mode | Half duplex, full duplex, autonegotiation |
| Number of terminal blocks | 1 line control outputs 1 power supply 3 discrete output 4 discrete input |
| Current consumption | 14 A 24 V DC on power supply |
| Mounting Support | 35 mm symmetrical DIN rail |
| Depth | 3.4 in (86.5 mm) |
| Height | 4.3 in (109 mm) |
| Width | 8.07 in (205 mm) |
| Product Weight | 2.9 lb(US) (1.3 kg) |

Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Preventa Safety automation |
| Product or Component Type | Preventa safety remote mixed I/O module |
| Safety module name | XPSMF3 |
| Safety module application | Extension of I/O capacity |
| Safety use category | Category 4 maximum EN 954-1 Performance level e EN/ISO 13849-1 SIL 3 EN/IEC 61508 |
| Function of module | Monitoring safety actuators discrete input Monitoring safety actuators discrete output Monitoring safety detection discrete input Monitoring safety dialogue discrete input |
| [Us] Rated Supply Voltage | 24 V DC - 15...20 % |
| Supply | SELV or PELV EN/IEC 60950 |
| Discrete input number | 20 not isolated |
| Discrete output number | 8, not isolated |
| Structure type | 10BASE-T/100BASE-TX |
Complementary
| Characteristic | Value(s) |
|---|---|
| Response Time | Depending on size of application |
| Voltage state 0 guaranteed | <= 5 V discrete input |
| Voltage state 1 guaranteed | 15...< 30 V discrete input |
| Current state 0 guaranteed | 1.25...1.5 mA discrete input) |
| Current state 1 guaranteed | <= 2 mA discrete input) |
| Discrete input voltage | 20 V |
| Discrete input current | 100 mA |
| Input protection type | Protected against short-circuit |
| Switching voltage | 7.5 V discrete input |
| Discrete output voltage | 24 V DC |
| Output voltage tolerance | +/- 2% |
| Discrete output current | 1 A 140 °F (60 °C) channels 4 and 8) 2 A 122 °F (50 °C) channels 4 and 8) 0.5 A 140 °F (60 °C) channels 1 to 3 and 5 to 7) <= 7 A all channels) |
| Minimum load | 2 mA per channel |
| Maximum leakage current | 1 mA 2 V at state 0 discrete output |
| Communication port protocol | Safe Ethernet 2 RJ45 100 Mbps, 10 Mbps dual twisted pair cable, category 5D or better |
| Exchange mode | Half duplex, full duplex, autonegotiation |
| Number of terminal blocks | 1 power supply 2 discrete input 2 discrete output |
| Current consumption | 8 A 24 V DC on power supply |
| Mounting Support | 35 mm symmetrical DIN rail |
| Depth | 2.6 in (66.5 mm) |
| Height | 4.3 in (109 mm) |
| Width | 8.1 in (207 mm) |
| Product Weight | 2.2 lb(US) (1 kg) |

Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Preventa Safety automation |
| Product or Component Type | Preventa safety remote mixed I/O module |
| Safety module name | XPSMF3 |
| Safety module application | Extension of I/O capacity |
| Safety use category | Category 4 maximum EN 954-1 Performance level e EN/ISO 13849-1 SIL 3 EN/IEC 61508 |
| Function of module | Monitoring safety actuators discrete input Monitoring safety actuators discrete output Monitoring safety detection discrete input Monitoring safety dialogue discrete input Monitoring safety dialogue discrete output Monitoring short-circuit and line break line control outputs |
| [Us] Rated Supply Voltage | 24 V DC - 15...20 % |
| Supply | SELV or PELV EN/IEC 60950 |
| Discrete input number | 8 not isolated |
| Number of outputs | 2 not isolated line control outputs |
| Discrete output number | 10, not isolated |
| Structure type | 10BASE-T/100BASE-TX |
Complementary
| Characteristic | Value(s) |
|---|---|
| Response Time | Depending on size of application |
| Associated fuse rating | 10 A, slow-blow |
| Voltage state 0 guaranteed | <= 5 V discrete input |
| Voltage state 1 guaranteed | 15...< 30 V discrete input |
| Current state 0 guaranteed | 1.25...1.5 mA discrete input) |
| Current state 1 guaranteed | <= 2 mA discrete input) |
| Discrete input voltage | 20 V |
| Discrete input current | 100 mA |
| Input protection type | Protected against short-circuit |
| Output voltage | 20 V line control outputs |
| Nominal output current | 60 mA line control outputs |
| Switching voltage | 7.5 V discrete input |
| Discrete output voltage | 24 V DC |
| Output voltage tolerance | +/- 2% |
| Discrete output current | 1 A 140 °F (60 °C) channels 1 and 2) 1 A 140 °F (60 °C) channels 4 and 8) 2 A 104 °F (40 °C) channels 4 and 8) 0.5 A 140 °F (60 °C) channels 1 to 3 and 5 to 7) <= 7 A all channels) |
| Inductive load | 500 mH discrete output |
| Maximum tungsten load | <10 W, channels 1 to 3 and 5 to 7 discrete output <25 W, channels 1 and 2 discrete output <25 W, channels 4 and 8 discrete output |
| Minimum load | 2 mA per channel |
| Maximum leakage current | 1 mA 2 V at state 0 discrete output |
| Communication port protocol | Safe Ethernet 2 RJ45 100 Mbps, 10 Mbps dual twisted pair cable, category 5D or better |
| Exchange mode | Half duplex, full duplex, autonegotiation |
| Number of terminal blocks | 1 power supply 2 discrete input 2 discrete output 2 line control outputs |
| Current consumption | 8 A 24 V DC on power supply |
| Mounting Support | 35 mm symmetrical DIN rail |
| Depth | 2.6 in (66.5 mm) |
| Height | 4.3 in (109 mm) |
| Width | 6.0 in (152 mm) |
| Product Weight | 2.2 lb(US) (1 kg) |
Modules