Laser Displacement Sensors

229 products

Showing 1 - 24 of 229 products

Showing 1 - 24 of 229 products
View
Keyence New Stock Image
Keyence LR-TB5000C Keyence
Sale price $571.14
In stock, 12 units

Specifications

Model

LR-TB5000C

Type

Cable with connector M12

Detectable distance

60 to 5000 mm 2.36" to 196.85"*1

Spot diameter

Variable
(use a spot diameter of 40 mm 1.57" or less)

Light source

Type

Red laser (660 nm)

Laser class

Class 2 laser product
(IEC60825-1,FDA (CDRH) Part1040.10*2)

Mutual interference prevention function

4 units (when using the interference prevention function)

Timer

OFF/OFF delay/ON delay/One-shot

Response time

1 ms/10 ms/25 ms/100 ms/1000 ms
selectable

I/O

Control output

NPN open collector/PNP open collector selectable
30 VDC or less, 50 mA or less, residual voltage: 2 V or less,
N.O./N.C. selectable
*3*4

Analog output

Current output/Voltage output selectable
Current output: 4 to 20 mA with a max. load resistance of 500 Ω
Voltage output: 0 to 10 V with an external load resistance of 5 kΩ or more
*3*4

Protection circuit

Protection against reverse power connection, power supply surges, output overcurrent, reverse output connection, and output surge

Power voltage

20 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS

Current consumption

50 mA or less (without load)*5

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Ambient light

Incandescent lamp/Sunlight: 10,0000 lux or less

Ambient temperature

-20 to +55 °C -4 to 131 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

1,000 m/s2, 6 times in each of the X, Y, and Z directions

Material

Case: Zinc die cast (Nickel chrome plating),
Indicator cover and buttons: PES,
Lens cover and display: PMMA (scratch-resistant coating specifications),
Cable bushing: PBT,
Cable: PVC,
M12 connector: TPE, PBT, Nickel-plated brass

Accompanying items

Instruction manual,
Laser warning and explanation labels

Weight

Approx. 160 g

*1 The range for displayable distance is from 50 to 5200.
*2 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice.
*3 You can select the I/O from the following combinations.
Control output × 2, control output + external input
Control output + analog output (LR-TB5000/TB5000C/TB5000CL only)
External input + analog output (LR-TB5000/TB5000C/TB5000CL only)
(For details on the setting method, see the instruction manual.)
*4 IO-Link specification v.1.1/COM2 (38.4 kbps) is supported. You can download a setup file from the KEYENCE website (http://www.keyence.com).
If you are using the product in an environment in which you cannot download files over the Internet, contact your nearest KEYENCE office.
*5 150 mA or less(with load)

Keyence New Stock Image
Keyence LR-TB2000C Keyence
Sale price $426.39
In stock, 14 units

Specifications

Model

LR-TB2000C

Type

Cable with connector M12

Detectable distance

60 to 2000 mm 2.36" to 78.74"*1

Spot diameter

Approx. ø4 mm ø0.16"

Light source

Type

Red laser (660 nm)

Laser class

Class 2 laser product
(IEC60825-1,FDA (CDRH) Part1040.10*2)

Mutual interference prevention function

4 units (when using the interference prevention function)

Timer

OFF/OFF delay/ON delay/One-shot

Response time

1 ms/10 ms/25 ms/100 ms/1000 ms
selectable

I/O

Control output

NPN open collector/PNP open collector selectable
30 VDC or less, 50 mA or less, residual voltage: 2 V or less,
N.O./N.C. selectable
*3*4

Analog output

-

Protection circuit

Protection against reverse power connection, power supply surges, output overcurrent, reverse output connection, and output surge

Power voltage

20 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS

Current consumption

45 mA or less (without load)*5

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Ambient light

Incandescent lamp/Sunlight: 10,0000 lux or less

Ambient temperature

-20 to +55 °C -4 to 131 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

1,000 m/s2, 6 times in each of the X, Y, and Z directions

Material

Case: Zinc die cast (Nickel chrome plating),
Indicator cover and buttons: PES,
Lens cover and display: PMMA (scratch-resistant coating specifications),
Cable bushing: PBT,
Cable: PVC,
M12 connector: TPE, PBT, Nickel-plated brass

Accompanying items

Instruction manual,
Laser warning and explanation labels

Weight

Approx. 85 g

*1 The range for displayable distance is from 50 to 2200.
*2 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice.
*3 You can select the I/O from the following combinations.
Control output × 2, control output + external input
Control output + analog output (LR-TB5000/TB5000C/TB5000CL only)
External input + analog output (LR-TB5000/TB5000C/TB5000CL only)
(For details on the setting method, see the instruction manual.)
*4 IO-Link specification v.1.1/COM2 (38.4 kbps) is supported. You can download a setup file from the KEYENCE website (http://www.keyence.com).
If you are using the product in an environment in which you cannot download files over the Internet, contact your nearest KEYENCE office.
*5 145 mA or less (with load)

Keyence New Stock Image
Keyence LR-W500C Keyence
Sale price $545.49
In stock, 17 units

Specifications

Model

LR-W500C

Type

M12 connector 4-pin type

Detecting distance

30 to 500 mm 1.18" to 19.69"

Min. spot diameter

Adjustable spot
Approx. ø3.5 mm at 100 mm ø0.14" at 3.94"
Approx. ø9 mm at 250 mm ø0.35" at 9.84"
Approx. ø18 mm at 500 mm ø0.71" at 19.69"

Light source

White LED

Mutual interference reduction function

Up to 2 units when alternate frequencies set

Timer

OFF/ON delay/OFF delay/One-shot

Response time

200 µs/1 ms/10 ms/100 ms/500 ms selectable *1

I/O

Control output

NPN open collector/PNP open collector selectable
30 VDC or less, 50 mA or less, remaining voltage: 2 V or less
N.O./N.C. selectable
*2

External input

Tuning /Transmission OFF selectable
Short circuit current: 1 mA or less for NPN/2 mA or less for PNP
For the applied voltage, see the wiring diagrams in the instruction manual.
For the input times, see the time charts in the instruction manual.
*2

Protection circuit

Protection against reverse power connection, power supply surge, output overcurrent, output surge, and reverse output connection

Power supply

Power voltage

10 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS

Current consumption

65 mA or less (without load) at 24 VDC;
120 mA or less (without load) at 12 VDC *3

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Ambient light

Incandescent lamp: 10,000 lux or less, Sunlight: 20,000 lux or less

Ambient temperature

-20 to +50 °C -4 to 122 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

1,000 m/s2, 6 times in each of the X, Y, and Z directions

Material

Case: Zinc die cast (Nickel chrome plating),
Indicator cover: PPSU, Buttons: PES
Lens cover and display: PMMA (scratch-resistant coating),
Spot adjustment dial: Iron (triiron tetraoxide coated)
Connector ring: PMP, Connector socket: PEI

Weight

Approx. 110 g

*1 When alternate frequencies are set, the response time increases by approximately 20%.
*2 IO-Link: Specification v.1.1/COM2 (38.4 kbps) is supported. The setup file can be downloaded from KEYENCE website (http://www.keyence.com).
If you are using the product in an environment in which you cannot download files over the Internet, contact your nearest KEYENCE office.
*3 195 mA or less (at 10 V, with load)

Keyence New Stock Image
Keyence LR-ZB100CP Keyence
Sale price $341.96
Only 6 units left

Specifications

Model

LR-ZB100CP

Type

Distance based laser sensor

Appearance

Rectangular

Output

PNP

Cable connection

M8 connector, 4-pin

Detectable distance

35 to 100 mm 1.38" to 3.94" (650 to 0)*1

Standard detectable deviation

35 to 50 mm 1.38" to 1.97": 1.5 mm 0.06"
50 to 100 mm 1.97" to 3.94": 3 mm 0.12"

Display resolution

2 (0.2 mm 0.008")

Spot size

Approx. 2 × 1 mm 0.08" × 0.04" at 100 mm 3.94"

Response time

1.5 ms / 10 ms / 50 ms selectable

Light source

Type

Red laser (660 nm)

Laser class

Class 1 laser product
(IEC60825-1, FDA (CDRH) Part1040.10*2)

Function

Indicator

3-digit 7-segment display (red),
output indicator (yellow),
DATUM indicator (orange),
1 spot indicator (green)

Timer

OFF/ON delay/OFF delay/One-shot

Specifications

Power voltage

10 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS

Power consumption

450 mW or less (18 mA or less at 24 V, 34 mA or less at 12 V)

Control output

PNP Open collector,
Applied voltage 30 VDC or less, Control current 100 mA or less,
Residual voltage 1.2 V or less at 10 mA or less, 2 V or less at 10 to 100 mA

Protection circuit

Protection against reverse power connection, output overcurrent, output surge, reverse output connection

Output operation

Light-ON / Dark-ON selectable

External input

Input time calibration: 35 ms or more ON, 35 ms or more OFF
Laser emission stop: 2 ms or more ON, 20 ms or more OFF
Short-circuit current NPN: 1 mA or less/PNP: 2 mA or less

Environmental resistance

Enclosure rating

IP68 (IEC60529), IP69K (DIN40050-9), NEMA 4X, 6P, 13 (NEMA250), ECOLAB*3, Diversey*3

Insulation resistance

20 MΩ or more (500 VDC)

Ambient light

Incandescent lamp: 4,000 lux or less
Sunlight: 8,000 lux or less*4

Ambient temperature

-10 to +50 °C 14 to 122 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Storage temperature

-25 to +75 °C -13 to 167 °F (No freezing)

Withstand voltage

1,000 VAC, 50/60 Hz, 1 min

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

1,000 m/s2, 6 times in each of the X, Y, and Z directions

Material

Case: SUS316L, Display: PES, Lens cover: PMMA with scratch-resistant coating,
Packing/Connector ring: FKM

Accompanying items

Instruction Manual,
Certification/Identification label (FDA)

Weight

Approx. 55 g

*1 Display readings can be used as a guide for the detecting distance. When the setting value is tuned, the readout shifts. When the value exceeds "-99", "-FF" is displayed.
*2 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice.
*3 Have passed resistance tests with cleaning agents from multiple manufactures.
*4 When the response time is 10 ms

Keyence New Stock Image
Keyence LR-ZH490CB Keyence
Sale price $933.03
In stock, 12 units

Specifications

Model

LR-ZH490CB*1

Type

U.C.D. Function
Distance based laser sensor

Appearance

M18 Threaded mount

Output

NPN/PNP selectable

Cable connection

M12 connector, 4-pin

Detectable distance

25 to 490 mm 0.98" to 19.29" (465 to 0)*2

Standard detectable deviation

25 to 170 mm 0.98" to 6.69": 9 mm 0.35"
170 to 290 mm 6.69" to 11.42": 25 mm 0.98"
290 to 390 mm 11.42" to 15.35": 40 mm 1.57"
390 to 490 mm 15.35" to 19.29": 50 mm 1.97"

Display resolution

1 to 5 (1 to 5 mm 0.04" to 0.20")

Spot size

Approx. ø3 mm ø0.12"

Response time

1.5 ms / 10 ms / 50 ms selectable

Light source

Type

Red laser (660 nm)

Laser class

Class 2 laser product (IEC60825-1)
Class II Laser product (FDA(CDRH) Part1040.10)

Function

Indicator

3-digit 7-segment display (white),
output indicator (yellow),
DATUM indicator (orange),
1 spot indicator (green)

Timer

OFF/ON delay/OFF delay/One-shot

Specifications

Power voltage

10 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS

Power consumption

450 mW or less (18 mA or less at 24 V, 34 mA or less at 12 V)

Control output

NPN open collector/PNP Open collector selectable,
Applied voltage 30 VDC or less, Control current 100 mA or less,
Residual voltage 1.2 V or less at 10 mA or less, 2 V or less at 10 to 100 mA

Protection circuit

Protection against reverse power connection, output overcurrent, output surge, reverse output connection

Output operation

Light-ON / Dark-ON selectable

External input

Input time calibration: 35 ms or more ON, 35 ms or more OFF
Laser emission stop: 2 ms or more ON, 20 ms or more OFF
Short-circuit current NPN: 1 mA or less/PNP: 2 mA or less

Environmental resistance

Enclosure rating

IP68 (IEC60529), IP69K (DIN40050-9), NEMA 4X, 6P, 13 (NEMA250), ECOLAB*3, Diversey*3

Insulation resistance

20 MΩ or more (500 VDC)

Ambient light

Incandescent lamp: 10,000 lux or less
Sunlight: 20,000 lux or less at 240 mm 9.45"*4
Incandescent lamp: 2,000 lux or less
Sunlight: 4,000 lux or less at 490 mm 19.29"*4

Ambient temperature

-10 to +50 °C 14 to 122 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Storage temperature

-25 to +75 °C -13 to 167 °F (No freezing)

Withstand voltage

1,000 VAC, 50/60 Hz, 1 min

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

1,000 m/s2, 6 times in each of the X, Y, and Z directions

Material

Case: SUS316L, Display: PES, Lens cover: PMMA with scratch-resistant coating,
Packing/Connector ring: FKM, Nut: SUS316L, Lock washer: SUS304

Accompanying items

Instruction Manual,
FDA warning/certification/identification label,
Laser warning/explanation labels

Weight

Approx. 75 g

*1 IO-Link specification v.1.1/COM2 (38.4 kbps) is supported. (LR-ZH490CB : Only when PNP output is selected.) You can download a setup file from the KEYENCE website. If using the product in an environment in which downloading files over the internet is not possible, contact your nearest KEYENCE office.
*2 Display readings can be used as a guide for the detecting distance. When the setting value is tuned, the readout shifts. When the value exceeds "-99", "-FF" is displayed.
*3 Have passed resistance tests with cleaning agents from multiple manufactures.
*4 When the response time is 10 ms

Keyence New Stock Image
Keyence LR-W70C Keyence
Sale price $474.65
Only 9 units left

Specifications

Model

LR-W70C

Type

Small/Dual Spot Type
M12 connector 4-pin type

Detecting distance

30 to 70 mm 1.18" to 2.76"

Min. spot diameter

Approx. 1.6 x 2.9mm at 50 mm 0.06" × 0.11" at 1.97"

Light source

White LED

Mutual interference reduction function

Up to 2 units when alternate frequencies set

Timer

OFF/ON delay/OFF delay/One-shot

Response time

1-Spot Mode: 200 µs, 1 ms, 10 ms, 100 ms, 500 ms selectable
2-Spot Mode, Difference Monitoring: 500 µs, 2.5 ms, 20 ms, 200 ms, 999 ms selectable
2-Spot Mode, 2-Point Matching: 400 µs, 2 ms, 20 ms, 200 ms, 999 ms selectable*1

I/O

Control output

NPN open collector/PNP open collector selectable
30 VDC or less, 50 mA or less, remaining voltage: 2 V or less
N.O./N.C. selectable
*2

External input

Tuning /Transmission OFF selectable
Short circuit current: 1 mA or less for NPN/2 mA or less for PNP
For the applied voltage, see the wiring diagrams in the instruction manual.
For the input times, see the time charts in the instruction manual.
*2

Protection circuit

Protection against reverse power connection, power supply surge, output overcurrent, output surge, and reverse output connection

Power supply

Power voltage

10 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS

Current consumption

60 mA or less (without load) at 24 VDC;
110 mA or less (without load) at 12 VDC)*3

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Ambient light

Incandescent lamp: 10,000 lux or less, Sunlight: 20,000 lux or less

Ambient temperature

-20 to +50 °C -4 to 122 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

1,000 m/s2, 6 times in each of the X, Y, and Z directions

Material

Case: Zinc die cast (Nickel chrome plating),
Indicator cover: PPSU, Buttons: PES,
Lens cover and display: PMMA (scratch-resistant coating),
Connector ring: PMP, Connector socket: PEI

Weight

Approx. 75 g

*1 When alternate frequencies are set, the response time increases by approximately 20%.
*2 IO-Link: Specification v.1.1/COM2 (38.4 kbps) is supported. The setup file can be downloaded from KEYENCE website (http://www.keyence.com).
If you are using the product in an environment in which you cannot download files over the Internet, contact your nearest KEYENCE office.
*3 180 mA or less (at 10 V, with load)

LK-G5001 Keyence
Keyence LK-G5001 Keyence
Sale price $1,872.36
Only 8 units left

Specifications

Model

LK-G5001

Type

Separate type Main controller

Sensor head compatibility

Compatible

No. of connectable sensor heads

2

Display

Minimum display unit

0.001 µm

Display range

±999.999 µm to ±9999.99 mm (7 settings selectable)

Display cycle

Approx 10 times/sec.

Display interface

Display port

Either the display unit (LK-HD500) or dedicated touch panel (LK-HD1001) can be connected

LED indicator

LASER ON

Terminal block

Analog output voltage

±10 V output, Output impedance: 100 Ω*1

Analog current output

4 to 20 mA, Maximum load resistance: 350 Ω*1

No. of analog outputs

2*1

TIMING 1 input

Non-voltage input*2

RESET 1 input

Auto-zero 1 input

Laser remote input

Non-voltage input*1

Alarm output

NPN open-collector output*1

General comparator output

Expansion connector

TIMING input

Non-voltage input*1

RESET input

Auto-zero input

Program switching input

Binary selection input

Alarm output

NPN open-collector output*1

Comparator output

Binary output

RS-232C interface

Baud rate: 9600 to 115200 bps
Data length: 8 bits Stop bit length: 1 bit Parity: None/even/odd

USB interface

USB 2.0 Hi-Speed compliant*3

Ethernet interface

100Base-TX/10Base-T*4

EtherNet/IP™interface

Cyclic communication (implicit messaging)
Message communication (explicit messaging) : UCMM and Class3 Number of connections: 32 Complies with conformance test version CT14*5

PLC-Link

The following PLCs are supported:Mitsubishi Electric: MELSEC iQ-R Series, iQ-F Series, Q Series, L Series, FX Series
EtherNet/IP™, CC-Link, and DeviceNet® cannot be used in conjunction with PLC-Link

Head expansion unit connector

Up to 10 head expansion units can be connected to one main controller

Expansion unit connector

Either of the CC-Link unit (LK-CC100) or DeviceNet® unit (LK-DN100) can be connected

Power supply

Power supply voltage

24 VDC ±10%

Maximum current consumption

0.6 A or less with 1 head/3.5 A or less with 12 heads

Environmental resistance

Ambient temperature

When one or less head expansion unit is connected: 0 to +50 °C 32 to 122 °F.
When two or more head expansion units are connected: 0 to +40 °C 32 to 104 °F.

Relative humidity

35 to 85 % RH (No condensation)

Weight

Approx. 600 g

*1 NPN open-collector output rating: 50 mA max. (40 V max.), Residual voltage: 0.5 V max.
PNP open-collector output rating: 50 mA max. (30 V max.), Residual voltage: 0.5 V max.
Non-voltage input rating: ON voltage: 1 V max., OFF current: 0.6 mA max.
Voltage input rating: Maximum input rating: 26.4 V, ON voltage: 10.2 V, OFF current: 0.6 mA
Part of the input/output circuit of the LK-G5000 Series is internally common. Be careful that no potential difference is generated between the internally common terminals due to the potential difference between the cables/external devices. For details, refer to "Precautions on wiring" in the User's Manual.
*2 NPN open-collector output rating: 50 mA max. (40 V max.), Residual voltage: 0.5 V max.
PNP open-collector output rating: 50 mA max. (30 V max.), Residual voltage: 0.5 V max.
Non-voltage input rating: ON voltage: 1 V max., OFF current: 0.6 mA max.
Voltage input rating: Maximum input rating: 26.4 V, ON voltage: 10.2 V, OFF current: 0.6 mA
Part of the input/output circuit of the LK-G5000 Series is internally common. Be careful that no potential difference is generated between the internally common terminals due to the potential difference between the cables/external devices. For details, refer to "Precautions on wiring" in the User's Manual. This input is applied to all of the synchronized OUT.
*3 When a PC supporting USB 1.1 or USB 2.0 full speed is connected, the data refresh cycle and other operations may slow down.
*4 Use the Ethernet interface only for direct connections with a PC or for local network connections with a PC or LK-G5000 Series units.
*5 The EtherNet/IP™ interface cannot be used when a CC-Link unit or a DeviceNet® unit is installed.
EtherNet/IP™ is supported by the latest controllers. For details on which controllers support EtherNet/IP™ , contact your nearest KEYENCE office.

Keyence New Stock Image
Keyence LR-ZB250CP Keyence
Sale price $305.76
In stock, 11 units

Specifications

Model

LR-ZB250CP

Type

Distance based laser sensor

Appearance

Rectangular

Output

PNP

Cable connection

M8 connector, 4-pin

Detectable distance

35 to 250 mm 1.38" to 9.84" (215 to 0)*1

Standard detectable deviation

35 to 180 mm 1.38" to 7.09": 9 mm 0.35"
180 to 250 mm 7.09" to 9.84": 25 mm 0.98"

Display resolution

1 to 3 (1 to 3 mm 0.04" to 0.12")

Spot size

Approx. 2.4 × 1.2 mm 0.09" × 0.05" at 250 mm 9.84"

Response time

1.5 ms / 10 ms / 50 ms selectable

Light source

Type

Red laser (660 nm)

Laser class

Class 1 laser product
(IEC60825-1, FDA (CDRH) Part1040.10*2)

Function

Indicator

3-digit 7-segment display (red),
output indicator (yellow),
DATUM indicator (orange),
1 spot indicator (green)

Timer

OFF/ON delay/OFF delay/One-shot

Specifications

Power voltage

10 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS

Power consumption

450 mW or less (18 mA or less at 24 V, 34 mA or less at 12 V)

Control output

PNP Open collector,
Applied voltage 30 VDC or less, Control current 100 mA or less,
Residual voltage 1.2 V or less at 10 mA or less, 2 V or less at 10 to 100 mA

Protection circuit

Protection against reverse power connection, output overcurrent, output surge, reverse output connection

Output operation

Light-ON / Dark-ON selectable

External input

Input time calibration: 35 ms or more ON, 35 ms or more OFF
Laser emission stop: 2 ms or more ON, 20 ms or more OFF
Short-circuit current NPN: 1 mA or less/PNP: 2 mA or less

Environmental resistance

Enclosure rating

IP68 (IEC60529), IP69K (DIN40050-9), NEMA 4X, 6P, 13 (NEMA250), ECOLAB*3, Diversey*3

Insulation resistance

20 MΩ or more (500 VDC)

Ambient light

Incandescent lamp: 2,000 lux or less
Sunlight: 4,000 lux or less*4

Ambient temperature

-10 to +50 °C 14 to 122 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Storage temperature

-25 to +75 °C -13 to 167 °F (No freezing)

Withstand voltage

1,000 VAC, 50/60 Hz, 1 min

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

1,000 m/s2, 6 times in each of the X, Y, and Z directions

Material

Case: SUS316L, Display: PES, Lens cover: PMMA with scratch-resistant coating,
Packing/Connector ring: FKM

Accompanying items

Instruction Manual,
Certification/Identification label (FDA)

Weight

Approx. 55 g

*1 Display readings can be used as a guide for the detecting distance. When the setting value is tuned, the readout shifts. When the value exceeds "-99", "-FF" is displayed.
*2 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice.
*3 Have passed resistance tests with cleaning agents from multiple manufactures.
*4 When the response time is 10 ms

LK-G5001V Keyence
Keyence LK-G5001V Keyence
Sale price $2,253.37
Only 5 units left

Specifications

Model

LK-G5001V*1*2

Separate type

LK-G5001/LK-HD500

Type

Main controller

Sensor head compatibility

Compatible

No. of connectable sensor heads

2

Display

Minimum display unit

LK-HD500: 0.001 µm

Display range

LK-HD500: ±999.999 µm to ±9,999.99 mm (7 settings selectable)

Display cycle

LK-HD500: Approx. 10 times/sec.

Display interface

Display port

Either the display unit (LK-HD500) or dedicated touch panel (LK-HD1001) can be connected

LED indicator

LASER ON

Terminal block

Analog output voltage

±10 V output, Output impedance: 100 Ω

Analog current output

4 to 20 mA, Maximum load resistance: 350 Ω

No. of analog outputs

2

TIMING 1 input

Non-voltage input*3

RESET 1 input

Auto-zero 1 input

Laser control input

Non-voltage input*4

Laser remote input

Non-voltage input

Alarm output

NPN open-collector output

General comparator output

Expansion connector

TIMING input

Non-voltage input

RESET input

Auto-zero input

Program switching input

Binary selection input

Alarm output

NPN open-collector output

Comparator output

Binary output

RS-232C interface

Baud rate: 9,600 to 115,200 bps
Data length: 8 bits, Stop bit length: 1 bit, Parity: None/even/odd

USB interface

USB 2.0 Hi-Speed compliant*5

Ethernet interface

100Base-TX/10Base-T*6

EtherNet/IP™interface

Cyclic communication (implicit messaging)
Message communication (explicit messaging) : UCMM and Class3 Number of connections: 32 Complies with conformance test version CT14*7

PLC-Link

The following PLCs are supported:Mitsubishi Electric: MELSEC iQ-R Series, iQ-F Series, Q Series, L Series, FX Series
EtherNet/IP™, CC-Link, and DeviceNet® cannot be used in conjunction with PLC-Link

Head expansion unit connector

Up to 10 head expansion units can be connected to one main controller

Expansion unit connector

Either of the CC-Link unit (LK-CC100) or DeviceNet® unit (LK-DN100) can be connected

Power supply

Power supply voltage

24 VDC ±10 %

Maximum current consumption

0.6 A or less with 1 head/3.5 A or less with 12 heads

Environmental resistance

Ambient temperature

When one or less head expansion unit is connected: 0 to +50 °C 32 to 122 °F.
When two or more head expansion units are connected: 0 to +40 °C 32 to 104 °F.

Relative humidity

35 to 85 % RH (No condensation)

Weight

Approx. 600 g

*1 NPN open-collector output rating: 50 mA max. (40 V max.), Residual voltage: 0.5 V max.
Non-voltage input rating: ON voltage: 1 V max., OFF current: 0.6 mA max.
*2 Part of the input/output circuit of the LK-G5000 Series is internally common. Be careful that no potential difference is generated between the internally common terminals due to the potential difference between the cables/external devices. For details, refer to "Precautions on wiring" in the User's Manual.
*3 This input is applied to all of the synchronized OUT.
*4 When the laser class 3B sensor head is connected, a key-operated switch must be used for the input to this terminal. The laser is emitted only when the key-operated switch is set to the ON position. (Select a key which can be removed only when it is set to the OFF position.)
When the laser class 2/3R sensor head is connected, the laser turns on when this terminal is opened and turns off when it is short-circuited.
*5 When a PC supporting USB 1.1 or USB 2.0 full speed is connected, the data refresh cycle and other operations may slow down.
*6 Use the Ethernet interface only for direct connections with a PC or for local network connections with a PC or LK-G5000 Series units.
*7 The EtherNet/IP™ interface cannot be used when a CC-Link unit or a DeviceNet® unit is installed.
EtherNet/IP™ is supported by the latest controllers. For details on which controllers support EtherNet/IP™ , contact your nearest KEYENCE office.

Keyence Stock Image
Keyence LJ-V7000 Keyence
Sale price $3,023.71
Only 9 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Keyence New Stock Image
Keyence LJ-V7060 Keyence
Sale price $1,228.44
In stock, 11 units

Specifications

Model

LJ-V7060

Mounting conditions

Diffuse reflection

Reference distance

60 mm 2.36"

Measurement range

Z-axis (height)

±8 mm 0.31"
(F.S.=16 mm 0.63")

X-axis (width)

NEAR side

13.5 mm 0.53"

Reference distance

15 mm 0.59"

Far side

Light source

Type

Blue semiconductor laser

Wavelength

405 nm (visible beam)

Laser class

Class 2M Laser Product*1
(IEC60825-1, FDA(CDRH) Part 1040.10*2)

Output

10 mW

Spot size (reference distance)

Approx. 21 mm × 45 µm
0.83" × 0.001772"

Repeatability

Z-axis (height)

0.4 µm 0.000016"*3*4

X-axis (width)

5 µm 0.000197"*3*5

Linearity

Z-axis (height)

±0.1% of F.S.*6

Profile data interval

X-axis (width)

20 µm 0.0008"

Sampling cycle (trigger interval)

Top speed: 16 µs (high-speed mode), Top speed: 32 µs (advanced function mode)*7

Temperature characteristics

0.01% of F.S./°C

Environmental resistance

Enclosure rating

IP67 (IEC60529)*8

Ambient light

Incandescent lamp: 10,000 lux max.*9

Ambient temperature

0 to +45 °C 32 to 113 °F*10

Relative humidity

85% RH or less (no condensation)

Vibration resistance

10 to 57 Hz, Double amplitude 1.5 mm 0.06", 3 hours in each of the X, Y, and Z directions

Shock resistance

15 G/6 ms

Material

Aluminum

Weight

Approx. 450 g

*1 Do not look into the beam directly using any optical instruments (such as eye loupes, magnifiers, microscopes, telescopes, or binoculars).
Viewing the laser output with an optical instrument may pose an eye hazard.
*2 The laser classification for FDA(CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice.
*3 This value is from a case in which measurement has been performed with a reference distance with 4,096 times of averaging.
*4 The measurement targets are KEYENCE standard targets. This value is from a case in which the average height of the default setting area has been measured in height mode. All other settings are default.
*5 The measurement target is a pin gauge. This value is from a case in which the position of the intersection between the rounded surface of the pin gauge and the edge level has been measured in position mode. All other settings are default.
*6 The measurement targets are KEYENCE standard targets. The profile data is from a case in which measurement has been performed with 64 times of smoothing and 8 times of averaging. All other settings are default.
*7 For high-speed mode, when the measurement area is at its minimum, binning is ON, image capture mode is set to standard, and parallel image capture is ON.
All other settings are default. For advanced function mode, when the measurement area is at its minimum, binning is ON and image capture mode is set to standard. All other settings are default.
*8 This value is from a case in which the sensor head cable (CB-B*) or extension cable (CB-B*E) has been connected.
*9 This is the illuminance for the light-receiving surface of the sensor head during white paper measurement when light has been shined onto the white paper.
*10 The sensor head must be mounted on a metal plate for use.

Keyence Stock Image
Keyence LJ-V7001 Keyence
Sale price $818.63
Only 8 units left

Specifications

Model

LJ-V7001

Number of connectable sensors

Max. 2 units

Display

Minimum
displayable unit

0.1 µm, 0.00001 mm2, 0.01°

Maximum display range

±9999.99 mm 393.7", ±9999.99 mm2

Input terminal block

Laser remote interlock input

No-voltage input*1

Input
terminal block

Encoder input

NPN open collector output/PNP open collector output (5V / 12V / 24V) line driver output

Input terminal block

Trigger input

No-voltage input*1

Timing 1,2 input

Auto-zero 1,2 input

Input
terminal block

Reset 1, 2 input

Input terminal
block

Start measurement/stop input

Start storage/stop input

Clear memory input

Laser OFF input

Program switch input

No-voltage input x 4 inputs*1

Output terminal block

Analog voltage output

±10 V x 2 outputs, Output impedance: 100 Ω

Output
terminal block

OUT comparator output

NPN open collector output x 12 outputs*2
(Can freely assign 16 OUTs x 3 stage judgment results)

Strobe output

NPN open collector output*2

Disable trigger output

Memory FULL output

Ready output

Output terminal block

Error output

NPN open collector output (N.C.)*2

PC interface

Ethernet

1000BASE-T/100BASE-TX*3

USB

USB 2.0 high speed compliant (USB 1.1 Full-SPEED compatible)*3

RS232C

Measurement data output and control I/O (Can select a baud rate of up to 115,200 bits/s)

Rating

Power voltage

24 VDC ±10 %, including Ripple (P-P)

Current consumption

1.3 A or less when connected to 1 head
1.9 A or less when connected to 2 heads

Environmental resistance

Ambient temperature

0 to +50 °C 32 to 122 °F

Relative humidity

85% RH or less (no condensation)

Weight

Approx. 1,500 g

*1 The rating for non-voltage input is up to 1 V for ON voltage and up to 0.6 mA for OFF current
*2 The rating for NPN open-collector output is up to 50 mA (40 V or less), residual voltage of up to 1 V
*3 DLL and LabVIEW programs are available. Contact your local sales office for details.

Keyence Stock Image
Keyence LK-HD500 Keyence
Sale price $387.26
Only 5 units left

Specifications

Model

LK-HD500

Type

Display unit

Supported models

LK-G5000
LK-G5000P

Display

Minimum display unit

0.001 µm

Display range

±999.999 µm to ±9,999.99 mm (selectable from 7 levels)

Display cycle

10 times/sec.

LK-H152 Keyence
Keyence LK-H152 Keyence
Sale price $3,823.69
Only 8 units left

Specifications

Model

LK-H152

Mounting mode

Diffuse reflective / Specular reflective*1

Reference distance

Diffuse reflective: 150 mm 5.91"
Specular reflective: 147.5 mm 5.81"

Measuring range

Diffuse reflective: ±40 mm ±1.57"
Specular reflective: -39.5 mm to +24.4 mm -1.56" to +0.96"*2

Light source

Type

Red semiconductor laser

Wavelength

655nm

Laser class

IEC 60825-1: Class 2
FDA(CDRH)21CFR Part 1040.10: Class II

Output

0.95mW

Spot diameter (at standard distance)

ø120 µm

Linearity

±0.02% of F.S. (F.S.= 80 mm 3.15")*3

Repeatability

0.25 µm*4

Sampling cycle

2.55/5/10/20/50/100/200/500/1000 µs (9 steps selectable)

Temperature characteristics

0.01% of F.S. (F.S.= 80 mm 3.15")

Environmental resistance

Enclosure rating

IP67

Ambient light

Incandescent lamp or fluorescent lamp: 5,000 lux max.

Ambient temperature

0 to +50 °C 32 to 122 °F*5

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Aluminum die-cast

Weight

Approx. 300 g

*1 Use one of the following dark filters when measuring a transparent or mirror surface object: LK-H082/LK-H087: LK-F3, LK-H152/LK-H157: LK-F2
*2 Measurement range when the sampling cycle is 20 µs or more.
*3 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008/LK-H008W) is measured in the normal measurement mode.
*4 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008/LK-H008W) is measured at the reference distance with the number of averaging measurements set to 16384. The value in parentheses is a typical e x ample of a measurement with the number of averaging measurements set to 65536 and the sampling cycle to 200 µs.
*5 When the ambient temperature rises to 40 °C 104 °F or more, mount this on a metal plate before use.

keyence Stock Image
Keyence LJ-H3 Keyence
Sale price $556.88
Only 3 units left

Specifications

Model

LJ-H3

Type

Setup/Monitor software

Operating System

Windows 11 Pro
Windows 10 *1
Windows 7 (SP1 or later)*2
Windows Vista (SP2 or later)*3
Windows XP (SP3 or later)*4

Supported languages

English, Japanese, German, French, Simplified Chinese, Traditional Chinese

CPU

Core i3 2.3 GHz or faster

Memory capacity

2GB or more

L2 cache memory

2MB or more

Available hard disk space

10 GB or more

Display

XGA (1024×768 pixel) or more, 256-colors or more

PC interface

Any one of the following must be loaded.
USB2.0/1.1*5, Ethernet 1000BASE-T/100BASE-TX*6

Weight

Approx. 400 g

*1 Compatible with each edition of Home, Pro, and Enterprise.
*2 Compatible with Home Premium, Professional, and Ultimate editions.
*3 Compatible with Ultimate, Business, Home Premium, and Home Basic editions.
*4 Compatible with Home Premium and Professional editions.
*5 Connection through a USB hub or converter is not guaranteed.
*6 Connections with a LAN through a router or converter are not guaranteed.

LK-G3001 Keyence
Keyence LK-G3001 Keyence
Sale price $1,237.31
In stock, 41 units

Specifications

Model

LK-G3001*1

Type

Separate monitor model*2

Display

Head compatibility

All LK-G sensor heads are compatible

Number of connectable sensors

Maximum of 2 units

Minimum display unit

0.01 µm

Display range

±9,999.99 mm to ±9,999.99 µm (Selectable from six levels)

Refresh rate

10 times/sec

Terminal block

Analog voltage output

±10 V x 2 outputs, output impedance: 100 Ω

Analog current output

4 to 20 mA x 2 outputs, maximum load resistance: 350 Ω

Timing input

For OUT1, non-voltage input

Reset input

Auto-zero input

Laser remote interlock input

Non-voltage input

Comparator output

For OUT1, NPN open-collector output

Alarm output

For OUT1, NPN open-collector output (N.C.)

Expansion connector

Timing input

For OUT2, non-voltage input

Reset input

Auto-zero input

Program switching input

Non-voltage input x 3 inputs

Laser-Off input

For Head A/Head B, non-voltage input

Comparator output

For OUT2, NPN open-collector output

Alarm output

For OUT2, NPN open-collector output (N.C.)

Binary

Binary output

Measured data output (21 bits), OUT1/OUT2 selectable, NPN open-collector output

Strobe output

NPN open-collector output

Binary selector output

Binary selector input

Non-voltage input

RS-232C interface

Measured data output and control input/output (Maximum baud rate: 115,200 bps, selectable)

USB interface

In conformity with USB Revision 2.0 Full speed (USB1.1 compatible)

Major functions

2 OUT simultaneous measurement, Operation, Averaging, Filter, Calibration, Measurement, AUTO ZERO,
Sampling frequency setting, Mutual interference prevention, Data storage, 8-program memory, ECO mode,
ABLE setting, Target setting, ABLE tuning, Selection of measurement surface of transparent target,
Statistics processing, Connection of setting support software, Selectable head-mounting, etc.

Rating

Power voltage

24 VDC ±10 %, Ripple (P-P) 10 % or less

Current consumption

500 mA or less with 1 head/600 mA or less with 2 heads

Environmental resistance

Ambient temperature

0 to +50 °C 32 to 122 °F

Relative humidity

35 to 85 % RH (No condensation)

Weight

Approx. 370 g

*1 The rating of the NPN open-collector: 50 mA max. (40 V max.), residual voltage of 1 V max.
The rating of non-voltage input: 1 V or less ON voltage, 0.6 mA or less OFF current.
*2 LK-G3001 can be operated singly. The measured value display and setting modifications can be performed on the display panel (LK-GD500) or via the setting support software (LK-H1W).

Keyence New Stock Image
Keyence LR-TB5000 Keyence
Sale price $486.71
Only 10 units left

Specifications

Model

LR-TB5000

Type

Cable

Detectable distance

60 to 5000 mm 2.36" to 196.85"*1

Spot diameter

Variable
(use a spot diameter of 40 mm 1.57" or less)

Light source

Type

Red laser (660 nm)

Laser class

Class 2 laser product
(IEC60825-1,FDA (CDRH) Part1040.10*2)

Mutual interference prevention function

4 units (when using the interference prevention function)

Timer

OFF/OFF delay/ON delay/One-shot

Response time

1 ms/10 ms/25 ms/100 ms/1000 ms
selectable

I/O

Control output

NPN open collector/PNP open collector selectable
30 VDC or less, 50 mA or less, residual voltage: 2 V or less,
N.O./N.C. selectable
*3*4

Analog output

Current output/Voltage output selectable
Current output: 4 to 20 mA with a max. load resistance of 500 Ω
Voltage output: 0 to 10 V with an external load resistance of 5 kΩ or more
*3*4

Protection circuit

Protection against reverse power connection, power supply surges, output overcurrent, reverse output connection, and output surge

Power voltage

20 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS

Current consumption

50 mA or less (without load)*5

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Ambient light

Incandescent lamp/Sunlight: 10,0000 lux or less

Ambient temperature

-20 to +55 °C -4 to 131 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

1,000 m/s2, 6 times in each of the X, Y, and Z directions

Material

Case: Zinc die cast (Nickel chrome plating),
Indicator cover and buttons: PES,
Lens cover and display: PMMA (scratch-resistant coating specifications),
Cable bushing: PBT,
Cable: PVC

Accompanying items

Instruction manual,
Laser warning and explanation labels

Weight

Approx. 200 g (Including cable)

*1 The range for displayable distance is from 50 to 5200.
*2 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice.
*3 You can select the I/O from the following combinations.
Control output × 2, control output + external input
Control output + analog output (LR-TB5000/TB5000C/TB5000CL only)
External input + analog output (LR-TB5000/TB5000C/TB5000CL only)
(For details on the setting method, see the instruction manual.)
*4 IO-Link specification v.1.1/COM2 (38.4 kbps) is supported. You can download a setup file from the KEYENCE website (http://www.keyence.com).
If you are using the product in an environment in which you cannot download files over the Internet, contact your nearest KEYENCE office.
*5 150 mA or less(with load)

Keyence New Stock Image
Keyence LR-ZB100CN Keyence
Sale price $354.02
In stock, 12 units

Specifications

Model

LR-ZB100CN

Type

Distance based laser sensor

Appearance

Rectangular

Output

NPN

Cable connection

M8 connector, 4-pin

Detectable distance

35 to 100 mm 1.38" to 3.94" (650 to 0)*1

Standard detectable deviation

35 to 50 mm 1.38" to 1.97": 1.5 mm 0.06"
50 to 100 mm 1.97" to 3.94": 3 mm 0.12"

Display resolution

2 (0.2 mm 0.008")

Spot size

Approx. 2 × 1 mm 0.08" × 0.04" at 100 mm 3.94"

Response time

1.5 ms / 10 ms / 50 ms selectable

Light source

Type

Red laser (660 nm)

Laser class

Class 1 laser product
(IEC60825-1, FDA (CDRH) Part1040.10*2)

Function

Indicator

3-digit 7-segment display (red),
output indicator (yellow),
DATUM indicator (orange),
1 spot indicator (green)

Timer

OFF/ON delay/OFF delay/One-shot

Specifications

Power voltage

10 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS

Power consumption

450 mW or less (18 mA or less at 24 V, 34 mA or less at 12 V)

Control output

NPN Open collector,
Applied voltage 30 VDC or less, Control current 100 mA or less,
Residual voltage 1.2 V or less at 10 mA or less, 2 V or less at 10 to 100 mA

Protection circuit

Protection against reverse power connection, output overcurrent, output surge, reverse output connection

Output operation

Light-ON / Dark-ON selectable

External input

Input time calibration: 35 ms or more ON, 35 ms or more OFF
Laser emission stop: 2 ms or more ON, 20 ms or more OFF
Short-circuit current NPN: 1 mA or less/PNP: 2 mA or less

Environmental resistance

Enclosure rating

IP68 (IEC60529), IP69K (DIN40050-9), NEMA 4X, 6P, 13 (NEMA250), ECOLAB*3, Diversey*3

Insulation resistance

20 MΩ or more (500 VDC)

Ambient light

Incandescent lamp: 4,000 lux or less
Sunlight: 8,000 lux or less*4

Ambient temperature

-10 to +50 °C 14 to 122 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Storage temperature

-25 to +75 °C -13 to 167 °F (No freezing)

Withstand voltage

1,000 VAC, 50/60 Hz, 1 min

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

1,000 m/s2, 6 times in each of the X, Y, and Z directions

Material

Case: SUS316L, Display: PES, Lens cover: PMMA with scratch-resistant coating,
Packing/Connector ring: FKM

Accompanying items

Instruction Manual,
Certification/Identification label (FDA)

Weight

Approx. 55 g

*1 Display readings can be used as a guide for the detecting distance. When the setting value is tuned, the readout shifts. When the value exceeds "-99", "-FF" is displayed.
*2 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice.
*3 Have passed resistance tests with cleaning agents from multiple manufactures.
*4 When the response time is 10 ms

LK-H050 Keyence
Keyence LK-H050 Keyence
Sale price $2,888.41
Only 8 units left

Specifications

Model

LK-H050

Mounting mode

Diffuse reflective

Reference distance

50 mm 1.97"

Measuring range

±10 mm ±0.39"*1

Light source

Type

Red semiconductor laser

Wavelength

655nm

Laser class

IEC 60825-1: Class 3R
FDA(CDRH)21CFR Part 1040.10: Class IIIa

Output

4.8mW

Spot diameter (at standard distance)

ø50 µm

Linearity

±0.02% of F.S. (F.S.= 20 mm 0.79")*2

Repeatability

0.025 µm*3

Sampling cycle

2.55/5/10/20/50/100/200/500/1000 µs (9 steps selectable)

Temperature characteristics

0.01% of F.S./°C (F.S.= 20 mm 0.79")

Environmental resistance

Enclosure rating

IP67

Ambient light

Incandescent lamp or fluorescent lamp: 10,000 lux max.

Ambient temperature

0 to +50 °C 32 to 122 °F*4

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Aluminum die-cast

Weight

Approx. 260 g

*1 Measurement range when the sampling cycle is 20 µs or more.
*2 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008/LK-H008W) is measured in the normal measurement mode.
*3 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008/LK-H008W) is measured at the reference distance with the number of averaging measurements set to 16384. The value in parentheses is a typical e x ample of a measurement with the number of averaging measurements set to 65536 and the sampling cycle to 200 µs.
*4 When the ambient temperature rises to 40 °C 104 °F or more, mount this on a metal plate before use.

Keyence New Stock Image
Keyence LR-ZH500P Keyence
Sale price $426.39
Only 9 units left

Specifications

Model

LR-ZH500P*1

Type

U.C.D. Function
Distance based laser sensor

Appearance

Rectangular

Output

PNP

Cable connection

2 m cable

Detectable distance

35 to 500 mm 1.38" to 19.69"(465 to 0)*2

Standard detectable deviation

35 to 180 mm 1.38" to 7.09": 9 mm 0.35"
180 to 300 mm 7.09" to 11.81": 25 mm 0.98"
300 to 400 mm 11.81" to 15.75": 40 mm 1.57"
400 to 500 mm 15.75" to 19.69": 50 mm 1.97"

Display resolution

1 to 5 (1 to 5 mm 0.04" to 0.20")

Spot size

Approx. ø3 mm ø0.12"

Response time

1.5 ms / 10 ms / 50 ms selectable

Light source

Type

Red laser (660 nm)

Laser class

Class 2 laser product (IEC60825-1)
Class II Laser product (FDA(CDRH) Part1040.10)

Function

Indicator

3-digit 7-segment display (white),
output indicator (yellow),
DATUM indicator (orange),
1 spot indicator (green)

Timer

OFF/ON delay/OFF delay/One-shot

Specifications

Power voltage

10 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS

Power consumption

450 mW or less (18 mA or less at 24 V, 34 mA or less at 12 V)

Control output

PNP Open collector,
Applied voltage 30 VDC or less, Control current 100 mA or less,
Residual voltage 1.2 V or less at 10 mA or less, 2 V or less at 10 to 100 mA

Protection circuit

Protection against reverse power connection, output overcurrent, output surge, reverse output connection

Output operation

Light-ON / Dark-ON selectable

External input

Input time calibration: 35 ms or more ON, 35 ms or more OFF
Laser emission stop: 2 ms or more ON, 20 ms or more OFF
Short-circuit current NPN: 1 mA or less/PNP: 2 mA or less

Environmental resistance

Enclosure rating

IP68 (IEC60529), IP69K (DIN40050-9), NEMA 4X, 6P, 13 (NEMA250), ECOLAB*3, Diversey*3

Insulation resistance

20 MΩ or more (500 VDC)

Ambient light

Incandescent lamp: 10,000 lux or less
Sunlight: 20,000 lux or less at 250 mm 9.84"*4
Incandescent lamp: 2,000 lux or less
Sunlight: 4,000 lux or less at 500 mm 19.69"*4

Ambient temperature

-10 to +50 °C 14 to 122 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Storage temperature

-25 to +75 °C -13 to 167 °F (No freezing)

Withstand voltage

1,000 VAC, 50/60 Hz, 1 min

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

1,000 m/s2, 6 times in each of the X, Y, and Z directions

Material

Case: SUS316L, Display: PES, Lens cover: PMMA with scratch-resistant coating,
Packing/Connector ring: FKM

Accompanying items

Instruction Manual,
FDA warning/certification/identification label,
Laser warning/explanation labels

Weight

Approx. 110 g (Including cable)

*1 IO-Link specification v.1.1/COM2 (38.4 kbps) is supported. You can download a setup file from the KEYENCE website. If using the product in an environment in which downloading files over the internet is not possible, contact your nearest KEYENCE office.
*2 Display readings can be used as a guide for the detecting distance. When the setting value is tuned, the readout shifts. When the value exceeds "-99", "-FF" is displayed.
*3 Have passed resistance tests with cleaning agents from multiple manufactures.
*4 When the response time is 10 ms

Keyence New Stock Image
Keyence LR-XN11P Keyence
Sale price $341.96
Only 7 units left

Specifications

Model

LR-XN11P

Type

PNP Output

Cable/Connector

Cable

Main Unit/Expansion Unit

Main Unit

No. of Control Outputs

2

No. of External Inputs

1

Response Time

500 µs*1/1 ms/3 ms/10 ms/200 ms Selectable

IO-Link

Functions

Timer Function

Timer OFF/Off-delay/On-delay/One-shot/On-Off delay/On-delay One-shot

I/O

Control Output

Open collector, 30 VDC or lower, N.O./N.C.
When used as a solitary unit: 100 mA or lower for 1 output; 100 mA or lower in total for 2 outputs; When expanding with multiple units: 50 mA or lower for 1 output
Residual voltage PNP: 1.6 V or lower (output current: 10 mA or lower)/2.2 V or lower (output current: 10 to 100 mA)

External Input

External Set/Laser OFF/Zero Shift/Hold Reset/Gyro Alert RST selectable
Short circuit current - PNP: 2 mA or lower
Input time: 3 ms or more ON, 20 ms or more OFF (25 ms or more ON, 25 ms or more OFF only when External Set is selected)

Unit Expansion

Up to 8 expansion units possible (including main unit, a total of 9 units connected) However, up to 16-unit expansion is possible when the LR-XN10 is used for expansion with the NU Series.

Protection Circuit

Protection against reverse power connection, protection against output overcurrent, protection against output surge, protection against reverse output connection

Number of Interference Prevention Devices

OFF/4 units/8 units selectable*2

Power supply

Power voltage

16 to 30 VDC*3 (including 10% ripple (P-P) or less), class 2

Power consumption

During normal operation: 1150 mW (47 mA or lower at 24 V, 64 mA or lower at 16 V), ECO ON/ALL: 985 mW (40 mA or lower at 24 V, 53 mA or lower at 16 V) (excluding Load Current)

Environmental resistance

Ambient temperature

−20 to +55°C -4°F to 131°F (no freezing)*4

Relative humidity

35 to 85% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power Spectral Density: 0.816 G2/Hz; X, Y, and Z directions

Shock resistance

500 m/s2 (50G); 3 times each for X, Y, and Z axes

Case Material

Main Unit and Cover: Polycarbonate

Accessories

Instruction manual

Weight

Approx. 80 g

*1 If 500 µs is selected, the following limitations apply.
· Only 2-point calibration can be performed.
· The detection range masking is set during calibration. (Manual setting of the masking range is not supported.)
· Output 2 is limited to an alarm output for errors and gyro issues, and standard/area cannot be used.
· The interference prevention function is not supported
*2 Selecting four or eight interference prevention units causes the response time to change as follows: 4 Units selected: 6 ms/18 ms/60 ms/1.2 s selectable; 8 Units selected: 12 ms/36 ms/120 ms/2.4 s selectable.
*3 When expanding the system with 4 or more expansion units, use a power voltage of 20 V or higher.
*4 Expansion by 1 or 2 units: −20 to +55°C -4°F to 131°F; Expansion by 3 to 10 units: -20 to +50°C -4°F to 122°F, Expansion by 11 to 16 units: -20 to +45°C -4°F to 113°F

keyence Stock Image
Keyence LJ-GC5 Keyence
Sale price $668.81
Only 3 units left

Specifications

Model

LJ-GC5

Type

Cable between the head and controller

Applicable product

LK-G3000 series

Number included

1

Cable end

Straight

Length

5 m 16.40'

Weight

Approx. 400 g

Keyence New Stock Image
Keyence LR-WF10 Keyence
Sale price $510.83
In stock, 15 units

Specifications

Model

LR-WF10

Type

Fiber Type
2 m 6.56' cable type

Detecting distance

Detecting Distance and Min. Spot Diameter Based on Attached Fiber Head

Min. spot diameter

Light source

White LED

Mutual interference reduction function

Up to 2 units when alternate frequencies set

Timer

OFF/ON delay/OFF delay/One-shot

Response time

250 µs, 1 ms, 10 ms, 100 ms, 500 ms Selectable*1*2

I/O

Control output

NPN open collector/PNP open collector selectable
30 VDC or less, 50 mA or less, remaining voltage: 2 V or less
N.O./N.C. selectable
*3

External input

Tuning /Transmission OFF selectable
Short circuit current: 1 mA or less for NPN/2 mA or less for PNP
For the applied voltage, see the wiring diagrams in the instruction manual.
For the input times, see the time charts in the instruction manual.
*3

Protection circuit

Protection against reverse power connection, power supply surge, output overcurrent, output surge, and reverse output connection

Power supply

Power voltage

10 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS

Current consumption

50 mA or less (without load) at 24 VDC;
90 mA or less (without load) at 12 VDC*4

Environmental resistance

Enclosure rating

IP65 (IEC60529)*5*6

Ambient light

Incandescent lamp: 10,000 lux or less, Sunlight: 20,000 lux or less

Ambient temperature

-20 to +45 °C -4 to 113 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

1,000 m/s2, 6 times in each of the X, Y, and Z directions

Material

Case: Zinc die cast (Nickel chrome plating),
Indicator cover: PPSU, Buttons: PES,
Display: PMMA (scratch-resistant coating),
Cable bushing: PBT, Cable: PVC,
Fiber locking mount: PBT, NBR, Silicone rubber, SUS304, SUSXM7
Adapter: PBT

Weight

Approx. 150 g (including cable)

*1 When alternate frequencies are set, the response time increases by approximately 20%.
*2 When using the IO-Link communication, if the response time is set in 1ms or more, it becomes approximately 10% slower.
*3 IO-Link: Specification v.1.1/COM2 (38.4 kbps) is supported. The setup file can be downloaded from KEYENCE website (http://www.keyence.com).
If you are using the product in an environment in which you cannot download files over the Internet, contact your nearest KEYENCE office.
*4 160 mA or less (at 10 V, with load)
*5 When the following small-diameter fiber units (the diameter of the cable is ø1.3 ø0.05" or ø1.0 ø0.04") are used, the IP65 rating cannot be satisfied (FU-4F/66/91/93/43/63/63T etc.). When any small-diameter fiber units except for the above are used, IP65 is applied.
*6 When the waterproof adapter A/B are not used at the time of installation of a small-diameter fiber unit, the IP65 enclosure rating cannot be satisfied.

keyence Stock Image
Keyence LJ-GC10 Keyence
Sale price $446.25
Only 2 units left

Specifications

Model

LJ-GC10

Type

Cable between the head and controller

Applicable product

LK-G3000 series

Number included

1

Cable end

Straight

Length

10 m 32.81'

Weight

Approx. 750 g

Recently viewed