Schneider
Schneider

Schneider

25001 products

Showing 24481 - 24504 of 25001 products

Showing 24481 - 24504 of 25001 products
View
XPSMCMMX0802G Schneider
Schneider XPSMCMMX0802G Schneider
Sale price $1,000.50
Only 2 units left

8 inputs 2 output pairs expansion module with spring term

XPSMCMRO0004 Schneider Electric
Schneider XPSMCMRO0004 Schneider Electric
Sale price $431.25
Only 2 units left

4 safety relay output expansion with backplane connection with screw term

XPSMCMRO0004DA Schneider
Schneider XPSMCMRO0004DA Schneider
Sale price $847.61
Only 2 units left

This Modicon MCM safe relay output expansion module has 4 start/restart interlock inputs, 4 relays with 8 status outputs and is fitted with captive screw clamp terminals. It is designed to monitor safety actuators for relay outputs, with a rated supply voltage of 24V DC and a maximum power dissipation of 3W. It is furnished with screw clamp terminals, removable terminal block for electrical connection. It is an IP20 rated product. The safe relay modules type XPSMCMER0004 use guided contact safety relays, each of which provides two N.O. contacts and one N.C. contact in addition to the N.C. feedback contact. This safe relay output expansion module figures LEDs on its front face, displaying the status (power supply, run, internal or external errors, inputs status, restart signal, output channels). The safe relay output modules type XPSMCMER0002 and XPSMCMER0004 do not require the backplane expansion connectors as they are directly wired to the selected OSSD. It weighs 0.3kg. Its dimension are 22.5mm (Depth), 99mm (Height) and 114.5mm (Width). Its housing is red. It is powered with 24 VDC. It is ideal for monitoring safety functions such as emergency stop, guard monitoring, perimeter guarding, position monitoring, speed monitoring and enabling movement. The safe controller CPU Modicon MCM are certified by TüV SÜD meeting the industrial safety standards of Category 4, PL e according to EN/ISO 13849-1 and SILCL 3 according to IEC/EN 61508 and IEC/EN 60261. Compatible accessory for safe relay output module is a memory card. The module instals on Omega 35mm DIN rail conforming to EN 50022. The Modicon MCM modular safety controller system provide flexibility and scalability from 8 inputs, 2 dual/4 single channel outputs up to 128 inputs, 16 dual/32 single channel outputs, up to 32 or 48 diagnostic status outputs. Modicon MCM modular safety controller system are designed to monitor multiple safety functions on and around a machine to minimise the risk of people accessing the dangerous moving parts of the machine.

Main

Characteristic Value(s)
Range of Product Preventa Safety automation
Product or Component Type Safe relay output module
Device short name XPSMCM
Electrical Connection Screw terminal
[Us] rated supply voltage 24 V - 20...20 % DC
Number of Outputs 4 relay
Discrete output number 8 solid state 125 mA diagnostics)
Function of module Monitoring safety actuators relay output

Complementary

Characteristic Value(s)
Maximum power dissipation in W 3 W
Integrated connection type Backplane expansion bus
Switching voltage 10 V DC
Associated fuse rating 3.5 A, slow-blow
Safety level Can reach category 4 ISO 13849-1
Can reach PL = e ISO 13849-1
Can reach SIL 3 IEC 61508
SILCL 3 IEC 62061
Quality labels CE
Output type Relay, 4 NO, volt-free
Quantity per Set 1
Switching time 12 ms
Maximum switching voltage 400 V AC
250 V DC
minimum switching current 20 mA
Maximum switching current 6 A
Number of terminal blocks 6
Local signalling 1 LED green PWR power ON
1 LED green RUN RUN (status)
1 LED red E IN internal error
1 LED red E EX external error
2 LEDs orange ADDR node address
4 LEDs green/red RELAY K1...K4 relay contact
4 LEDs yellow RST requires reset
8 LEDs yellow STATUS diagnostics output
Connections - terminals 2 captive screw clamp terminals, removable terminal block
1 captive screw clamp terminals, removable terminal block
Cable cross section 0.0003…0.002 in² (0.2…1.5 mm²) - AWG 24...AWG 16 flexible without cable end
0.0003…0.004 in² (0.2…2.5 mm²) - AWG 24...AWG 14 flexible without cable end
0.0004…0.002 in² (0.25…1 mm²) - AWG 23...AWG 18 flexible with cable end, without bezel
0.0004…0.004 in² (0.25…2.5 mm²) - AWG 23...AWG 14 flexible with cable end, with bezel
0.0004…0.004 in² (0.25…2.5 mm²) - AWG 23...AWG 14 flexible with cable end, without bezel
0.0008…0.002 in² (0.5…1.5 mm²) - AWG 20...AWG 16 flexible with cable end, with double bezel
0.0003…0.002 in² (0.2…1 mm²) - AWG 24...AWG 18 solid without cable end
0.0003…0.004 in² (0.2…2.5 mm²) - AWG 24...AWG 14 solid without cable end
Mounting support Omega 35 mm DIN rail EN 50022
Width 0.9 in (22.5 mm)
Height 3.9 in (99 mm)
Depth 4.5 in (114.5 mm)
Product Weight 0.73 lb(US) (0.33 kg)
XPSMCMRO0004DAG Schneider
Schneider XPSMCMRO0004DAG Schneider
Sale price$0.00
Sold Out

4 safety RO expansion with diag. out with backplane connection with spring term

XPSMCMRO0004G Schneider
Schneider XPSMCMRO0004G Schneider
Sale price$0.00
Sold Out

The safe relay output module provides 4 outputs and 8 solid state at 125mA (diagnostics) discrete outputs. It is designed to monitor safety actuators for relay outputs, with a rated supply voltage of 24V DC and a maximum power dissipation of 3W. It is furnished with spring clamp terminals, removable terminal block for electrical connection. It is an IP20 rated product. The safe relay modules type XPSMCMER0004 use guided contact safety relays, each of which provides two N.O. contacts and one N.C. contact in addition to the N.C. feedback contact. This safe relay output expansion module figures LEDs on its front face, displaying the status (power supply, run, internal or external errors, inputs status, restart signal, output channels). The safe relay output modules type XPSMCMER0002 and XPSMCMER0004 do not require the backplane expansion connectors as they are directly wired to the selected OSSD. It weighs 0.3kg. Its dimension are 22.5mm (Depth), 99mm (Height) and 114.5mm (Width). Its housing is red. It is powered with 24 VDC. It is ideal for monitoring safety functions such as emergency stop, guard monitoring, perimeter guarding, position monitoring, speed monitoring and enabling movement. The safe controller CPU Modicon MCM are certified by TüV SÜD meeting the industrial safety standards of Category 4, PL e according to EN/ISO 13849-1 and SILCL 3 according to IEC/EN 61508 and IEC/EN 60261. Compatible accessory for safe relay output module is a memory card. The module instals on Omega 35mm DIN rail conforming to EN 50022. The Modicon MCM modular safety controller system provide flexibility and scalability from 8 inputs, 2 dual/4 single channel outputs up to 128 inputs, 16 dual/32 single channel outputs, up to 32 or 48 diagnostic status outputs. Modicon MCM modular safety controller system are designed to monitor multiple safety functions on and around a machine to minimise the risk of people accessing the dangerous moving parts of the machine.

Main

Characteristic Value(s)
Range of Product Preventa Safety automation
Product or Component Type Safe relay output module
Device short name XPSMCM
Electrical Connection Spring terminal
[Us] rated supply voltage 24 V - 20...20 % DC
Number of Outputs 4 relay
Discrete output number 8 solid state 125 mA diagnostics)
Function of module Monitoring safety actuators relay output

Complementary

Characteristic Value(s)
Maximum power dissipation in W 3 W
Integrated connection type Backplane expansion bus
Switching voltage 10 V DC
Associated fuse rating 3.5 A, slow-blow
Safety level Can reach category 4 ISO 13849-1
Can reach PL = e ISO 13849-1
Can reach SIL 3 IEC 61508
SILCL 3 IEC 62061
Quality labels CE
Output type Relay, 4 NO, volt-free
Quantity per Set 1
Switching time 12 ms
Maximum switching voltage 400 V AC
250 V DC
minimum switching current 20 mA
Maximum switching current 6 A
Number of terminal blocks 4
Local signalling 1 LED green PWR power ON
1 LED green RUN RUN (status)
1 LED red E IN internal error
1 LED red E EX external error
2 LEDs orange ADDR node address
4 LEDs green/red RELAY K1...K4 relay contact
4 LEDs yellow RST reset
Connections - terminals 1 spring clamp terminals, removable terminal block
2 spring clamp terminals, removable terminal block
Cable cross section 0.0003…0.004 in² (0.2…2.5 mm²) - AWG 24...AWG 14 flexible without cable end
0.0004…0.004 in² (0.25…2.5 mm²) - AWG 23...AWG 14 flexible with cable end, with bezel
0.0004…0.004 in² (0.25…2.5 mm²) - AWG 23...AWG 14 flexible with cable end, without bezel
0.0003…0.004 in² (0.2…2.5 mm²) - AWG 24...AWG 14 solid without cable end
0.0008…0.002 in² (0.5…1 mm²) - AWG 20...AWG 18 flexible with cable end, with double bezel
Mounting support Omega 35 mm DIN rail EN 50022
Width 0.9 in (22.5 mm)
Height 3.9 in (99 mm)
Depth 4.5 in (114.5 mm)
Product Weight 0.7 lb(US) (0.3 kg)
XPSMCTC16 Schneider
Schneider XPSMCTC16 Schneider
Sale price$0.00
Sold Out

Main

Characteristic Value(s)
Range of Product Preventa Safety automation
Accessory / separate part designation Plug-in spring connector
Accessory / Separate Part Type Spring connector
Accessory / separate part category Connection accessories
Product Compatibility XPSMC16ZC
XPSMC16Z
XPSMC16ZP
Accessory / separate part destination Configurable safety controller

Complementary

Characteristic Value(s)
Wire stripping length 0.4 in (10 mm)
Product Weight 0.18 lb(US) (0.08 kg)
XPSMCTC32 Schneider
Schneider XPSMCTC32 Schneider
Sale price$0.00
Sold Out

Main

Characteristic Value(s)
Range of Product Preventa Safety automation
Accessory / separate part designation Plug-in spring connector
Accessory / Separate Part Type Spring connector
Accessory / separate part category Connection accessories
Product Compatibility XPSMC32ZP
XPSMC32ZC
XPSMC32Z
Accessory / separate part destination Configurable safety controller

Complementary

Characteristic Value(s)
Wire stripping length 0.4 in (10 mm)
Product Weight 0.24 lb(US) (0.11 kg)
XPSMCTS16 Schneider
Schneider XPSMCTS16 Schneider
Sale price$0.00
Sold Out

Main

Characteristic Value(s)
Range of Product Preventa Safety automation
Accessory / separate part designation Plug-in screw connector
Accessory / Separate Part Type Screw connector
Accessory / separate part category Connection accessories
Product Compatibility XPSMC16ZP
XPSMC16Z
XPSMC16ZC
Accessory / separate part destination Configurable safety controller

Complementary

Characteristic Value(s)
Tightening torque 4.4…5.3 lbf.in (0.5…0.6 N.m)
Wire stripping length 0.4 in (10 mm)
Product Weight 0.18 lb(US) (0.08 kg)
XPSMCTS32 Schneider
Schneider XPSMCTS32 Schneider
Sale price$0.00
Sold Out

Main

Characteristic Value(s)
Range of Product Preventa Safety automation
Accessory / separate part designation Plug-in screw connector
Accessory / Separate Part Type Screw connector
Accessory / separate part category Connection accessories
Product Compatibility XPSMC32Z
XPSMC32ZC
XPSMC32ZP
Accessory / separate part destination Configurable safety controller

Complementary

Characteristic Value(s)
Tightening torque 4.4…5.3 lbf.in (0.5…0.6 N.m)
Wire stripping length 0.4 in (10 mm)
Product Weight 0.24 lb(US) (0.11 kg)
XPSMCWIN Schneider Electric
Schneider XPSMCWIN Schneider Electric
Sale price$0.00
Sold Out

Main

Characteristic Value(s)
Range of Product Preventa Safety automation
Software Designation XPSMCWIN
Product or Component Type Configuration software
Software Type Configuration software
Software Version V2.10 (update file for V2.20 available in Schneider web site)
User Language Portuguese
Spanish
Dutch
English
Italian
French
Format CD-ROM
Operating System Windows 2000
Windows XP
Document type User manual

Complementary

Characteristic Value(s)
Software Function Configuring safety controllers XPSMC..Z.
Product Weight 1.15 lb(US) (0.52 kg)
XPSMF1DI1601 Schneider Electric

Main

Characteristic Value(s)
Range of Product Preventa Safety automation
Product or Component Type Preventa safety remote input module
Safety module name XPSMF1
Safety module application Extension of I/O capacity
Safety use category Category 4 maximum EN 954-1
Performance level e EN/ISO 13849-1
SIL 3 EN/IEC 61508
Function of module Monitoring safety detection discrete input
Monitoring safety dialogue discrete input
Monitoring short-circuit and line break remote line control output
[Us] Rated Supply Voltage 24 V DC - 15...20 %
Supply SELV or PELV EN/IEC 60950
Discrete input number 16 not isolated
Number of outputs 4 not isolated line control outputs
Structure type 10BASE-T/100BASE-TX

Complementary

Characteristic Value(s)
Response Time Depending on size of application
Voltage state 0 guaranteed <= 5 V discrete input
Voltage state 1 guaranteed >= 15 V discrete input
Current state 0 guaranteed 1...1.5 mA discrete input)
Current state 1 guaranteed >= 2 mA discrete input)
Discrete input voltage 19.2 V
Discrete input current 40 mA
Input protection type Protected against short-circuit
Output voltage 20 V line control outputs
Nominal output current 60 mA line control outputs
Switching voltage 7.5 V discrete input
Switching time 250 µs discrete input
Communication port protocol Safe Ethernet 2 RJ45 100 Mbps, 10 Mbps dual twisted pair cable, category 5D or better
Exchange mode Half duplex, full duplex, autonegotiation
Number of terminal blocks 1 discrete output
1 power supply
4 discrete input
Current consumption 0.8 A 24 V DC on power supply
Mounting Support 35 mm symmetrical DIN rail
Depth 2.6 in (66.5 mm)
Height 4.3 in (109 mm)
Width 6.0 in (152 mm)
Product Weight 1.5 lb(US) (0.7 kg)
XPSMF2DO801 Schneider Electric
Schneider XPSMF2DO801 Schneider Electric
Sale price$0.00
Sold Out

Main

Characteristic Value(s)
Range of Product Preventa Safety automation
Product or Component Type Preventa safety remote output relay module
Safety module name XPSMF2
Safety module application Extension of I/O capacity
Safety use category Category 4 maximum EN 954-1
Performance level e EN/ISO 13849-1
SIL 3 EN/IEC 61508
Function of module Monitoring safety actuators
Monitoring safety dialogue
[Us] Rated Supply Voltage 24 V DC - 15...20 %
Supply SELV or PELV EN/IEC 60950
Number of outputs 8 relay
Structure type 10BASE-T/100BASE-TX

Complementary

Characteristic Value(s)
Response Time Depending on size of application
Associated fuse rating 10 A, slow-blow
Output type Relay, 2 NO per output, volt-free
Minimum switching voltage 5 V 250 V AC output relay
5 V 250 V DC output relay
Switching current capacity 3 A / 100 A with internal fuse relay output
Maximum switching capacity in VA <240 VA 0.5 relay output
Maximum switching capacity in W <90 / 30 V relay output
<30 / 127 V relay output
<35 / 70 V relay output
Contacts material Silver alloy (Ag/Ni) relay output
Electrical durability 250000 cycles relay output
Mechanical durability 1000000 cycles relay output
Communication port protocol Safe Ethernet 2 RJ45 100 Mbps, 10 Mbps dual twisted pair cable, category 5D or better
Exchange mode Half duplex, full duplex, autonegotiation
Number of terminal blocks 1 power supply
8 relay output
Current consumption 0.6 A 24 V DC on power supply
Mounting Support 35 mm symmetrical DIN rail
Depth 3.4 in (86.5 mm)
Height 4.3 in (109 mm)
Width 8.1 in (207 mm)
Product Weight 2.9 lb(US) (1.3 kg)
XPSMF3542 Schneider Electric
Schneider XPSMF3542 Schneider Electric
Sale price$0.00
Sold Out

Main

Characteristic Value(s)
Range of Product Preventa Safety automation
Product or Component Type Preventa safety PLC compact
Safety module name XPSMF35
Safety module application For numerous machine safety functions and for the protection of personnel
Safety use category Category 4 EN 954-1/ISO 13849-1
SIL 3 IEC 61508
Structure type 10BASE-T/100BASE-TX, Modbus TCP/IP
10BASE-T/100BASE-TX, safe Ethernet

Complementary

Characteristic Value(s)
Function of module Closed circuit scanning of input channels analogue input circuit
Measuring 0 to 20 mA currents using shunt analogue input circuit
Monitoring safety actuators discrete output
Monitoring safety detection discrete input
Monitoring safety dialogue discrete input
Monitoring safety dialogue discrete output
Single-pole measuring of 0 to 10 V voltages analogue input circuit
[Us] Rated Supply Voltage 24 V DC - 15...20 %
No load current 0.75 A
Protection Type Internal fuse
Clock With, supplied by backup capacitor for 1 week following loss of supply
Response Time Depending on size of application
Memory description User logic 250 kB application
User logic 250 kB data
Discrete input number 24 not isolated
Voltage state 0 guaranteed <= 5 V discrete input
Voltage state 1 guaranteed 24...30 V discrete input
Current state 0 guaranteed 1...1.5 mA discrete input)
Current state 1 guaranteed 3.5...4.5 mA discrete input)
Discrete input voltage 20 V
Discrete input current 100 mA
Input protection type Protected against short-circuit to earth
Protected against short-circuit
Input overvoltage protection 500 V discrete input IEC 61000-4-5
-4…15 V analogue input circuit
Discrete output number 8
Discrete output voltage 24 V DC
Output voltage tolerance +/- 2%
Discrete output current 1 A 140 °F (60 °C) channels 4 and 8)
2 A 122 °F (50 °C) channels 4 and 8)
0.5 A 140 °F (60 °C) channels 1 to 3 and 5 to 7)
<= 7 mA all channels)
Minimum load 2 mA per discrete output
Maximum leakage current 1 mA 2 V at state 0 discrete output
Overload protection Shutdown of outputs concerned with cyclic reconnection
Analogue input number 8
Analogue Output Type Not isolated
External resistance 250 Ohm analogue input circuit
500 Ohm analogue input circuit
Analogue input range 0...20 mA 500 Ohm
0...10 V
Input voltage limits 0.1...11.5 V analogue input circuit
Input current limits 0.4…23 mA 500 Ohm analogue input circuit
Analogue input resolution 12 bits
Safety accuracy +/- 2 % analogue input circuit
Maximum internal input resistance 500 MOhm for signal source analogue input circuit
1 kOhm analogue input circuit
3.7 Ohm counting inputs
Counting input number 2
Counting input type Non isolated
Counting frequency 100 kHz
Operating threshold 0...0.05 V, 5 V low counting inputs
13...33 V, 24 V high counting inputs
-3...5 V, 24 V low counting inputs
4...6 V, 5 V high counting inputs
Counter inputs resolution 24 bits
DV/dt 1 V/µs counting inputs
Communication port protocol Modbus TCP/IP 4 RJ45 100 Mbps, 10 Mbps dual twisted pair cable, category 5D or better
Safe Ethernet 4 RJ45 100 Mbps, 10 Mbps dual twisted pair cable, category 5D or better
Modbus RTU 1 SUB-D 9-pin female, RS485 shielded dual twisted pair cable
Profibus 1 SUB-D 9-pin female, RS485 shielded dual twisted pair cable
Exchange mode Half duplex, full duplex, autonegotiation Modbus TCP/IP
Half duplex, full duplex, autonegotiation safe Ethernet
Method of access Slave Modbus
Slave Modbus TCP/IP
Slave Profibus
Number of addresses 122 Modbus
Concept Transparent Ready, Modbus TCP/IP
Web server Class A10, Modbus TCP/IP
Web services Modbus identification request, Modbus TCP/IP
Modbus TCP/IP messaging (reading/writing of data words), Modbus TCP/IP
Modbus TCP/IP server, Modbus TCP/IP
Standard 502, Modbus TCP/IP
Operating distance <= 500 m between station) shielded dual twisted pair cable counting inputs
<= 100 m between station) discrete input
<= 100 m between station) discrete output
<= 300 m between station) analogue input circuit
Number of terminal blocks 1 counting inputs
1 power supply
2 discrete output
4 analogue input circuit
5 discrete input
Connections - terminals Analogue input circuit captive screw clamp terminals, 2 x 0.5 mm² AWG 20) flexible with cable end
Counting inputs captive screw clamp terminals, 2 x 0.5 mm² AWG 20) flexible with cable end
Discrete input/output circuit captive screw clamp terminals, 2 x 0.5 mm² AWG 20) flexible with cable end
Discrete input/output circuit captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² AWG 28...AWG 16) flexible without cable end
Discrete input/output circuit captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² AWG 28...AWG 16) solid without cable end
Power supply captive screw clamp terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 12) flexible without cable end
Power supply captive screw clamp terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 12) solid without cable end
Discrete input/output circuit captive screw clamp terminals, 1 x 0.25...1 x 0.5 mm² AWG 22...AWG 20) flexible with cable end
Discrete input/output circuit captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² AWG 22...AWG 16) flexible without cable end
Power supply captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² AWG 22...AWG 16) flexible with cable end
Power supply captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² AWG 22...AWG 16) flexible without cable end
Discrete input/output circuit captive screw clamp terminals, 2 x 0.14...2 x 0.5 mm² AWG 28...AWG 20) solid without cable end
Discrete input/output circuit captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² AWG 28...AWG 18) flexible without cable end
Power supply captive screw clamp terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 12) flexible without cable end
Power supply captive screw clamp terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 12) solid without cable end
Discrete input/output circuit captive screw clamp terminals, 2 x 0.25...2 x 0.34 mm² AWG 22) flexible without cable end
Power supply captive screw clamp terminals, 2 x 0.25...2 x 1 mm² AWG 22...AWG 18) flexible without cable end
Power supply captive screw clamp terminals, 2 x 0.5...2 x 1.5 mm² AWG 22...AWG 16) flexible with cable end
Analogue input circuit captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² AWG 28...AWG 16) flexible without cable end
Counting inputs captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² AWG 28...AWG 16) flexible without cable end
Analogue input circuit captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² AWG 28...AWG 16) solid without cable end
Counting inputs captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² AWG 28...AWG 16) solid without cable end
Analogue input circuit captive screw clamp terminals, 1 x 0.25...1 x 0.5 mm² AWG 22...AWG 20) flexible with cable end
Counting inputs captive screw clamp terminals, 1 x 0.25...1 x 0.5 mm² AWG 22...AWG 20) flexible with cable end
Analogue input circuit captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² AWG 22...AWG 16) flexible without cable end
Counting inputs captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² AWG 22...AWG 16) flexible without cable end
Analogue input circuit captive screw clamp terminals, 2 x 0.14...2 x 0.5 mm² AWG 28...AWG 20) solid without cable end
Counting inputs captive screw clamp terminals, 2 x 0.14...2 x 0.5 mm² AWG 28...AWG 20) solid without cable end
Analogue input circuit captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² AWG 28...AWG 18) flexible without cable end
Counting inputs captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² AWG 28...AWG 18) flexible without cable end
Analogue input circuit captive screw clamp terminals, 2 x 0.25...2 x 0.34 mm² AWG 22) flexible without cable end
Counting inputs captive screw clamp terminals, 2 x 0.25...2 x 0.34 mm² AWG 22) flexible without cable end
Tightening torque 1.95…2.21 lbf.in (0.22…0.25 N.m)
Wire stripping length 0.4 in (9 mm)
Current consumption 9 A 24 V DC on power supply
Mounting Support 35 mm symmetrical DIN rail
Depth 2.6 in (66.5 mm)
Height 4.4 in (113 mm)
Width 10.0 in (253 mm)
Product Weight 2.6 lb(US) (1.2 kg)
XPSMF3AIO8401 Schneider Electric

Main

Characteristic Value(s)
Range of Product Preventa Safety automation
Product or Component Type Preventa safety remote mixed I/O module
Safety module name XPSMF3
Safety module application Extension of I/O capacity
Safety use category Category 4 maximum EN 954-1
Performance level e EN/ISO 13849-1
SIL 3 EN/IEC 61508
Structure type 10BASE-T/100BASE-TX

Complementary

Characteristic Value(s)
Function of module Single-pole measuring of 0 to 10 V voltages
Measuring, using shunt, 0/4 to 20 mA currents
Closed circuit scanning of input channels
[Us] Rated Supply Voltage 24 V DC - 15...20 %
Supply SELV or PELV EN/IEC 60950
Response Time Depending on size of application
Analogue input number 8
Analogue Input Type Not isolated
External resistance 250 Ohm analogue input circuit
500 Ohm analogue input circuit
Analogue input range 0...20 mA 500 Ohm
0...10 V
Input voltage limits 0.1...11.5 V
Input current limits 0.4…23 mA 500 Ohm
Analogue input resolution 12 bits
Safety accuracy +/- 2 % analogue input circuit
Maximum internal input resistance 500 MOhm for signal source
2 Ohm
Input overvoltage protection -4…15 V
Analogue output number 4
Analogue Output Type Not isolated
Analogue output range 4...20 mA
Output current limits 0…20 mA
Analogue output resolution 12 bits
Load impedance ohmic <= 600 Ohm analogue output
Relative error +/- 1 %
Maximum cable distance between devices 11.8 in (300 mm) analogue input circuit
11.8 in (300 mm) analogue output
Communication port protocol Safe Ethernet 2 RJ45 100 Mbps, 10 Mbps dual twisted pair cable, category 5D or better
Exchange mode Half duplex, full duplex, autonegotiation
Number of terminal blocks 1 power supply
5 analogue input/output circuit
Current consumption 0.8 A 24 V DC on power supply
Mounting Support 35 mm symmetrical DIN rail
Depth 8.1 in (207 mm)
Height 4.3 in (109 mm)
Width 3.8 in (97.5 mm)
Product Weight 2.09 lb(US) (0.95 kg)
XPSMF3DIO16801 Schneider Electric

Main

Characteristic Value(s)
Range of Product Preventa Safety automation
Product or Component Type Preventa safety remote mixed I/O module
Safety module name XPSMF3
Safety module application Extension of I/O capacity
Safety use category Category 4 maximum EN 954-1
Performance level e EN/ISO 13849-1
SIL 3 EN/IEC 61508
Function of module Monitoring safety actuators discrete input
Monitoring safety actuators discrete output
Monitoring safety detection discrete input
Monitoring safety dialogue discrete input
Monitoring safety dialogue discrete output
Monitoring short-circuit and line break line control outputs
[Us] Rated Supply Voltage 24 V DC - 15...20 %
Supply SELV or PELV EN/IEC 60950
Discrete input number 16 not isolated
Number of outputs 2 not isolated line control outputs
Discrete output number 16, not isolated
Structure type 10BASE-T/100BASE-TX

Complementary

Characteristic Value(s)
Response Time Depending on size of application
Associated fuse rating 16 A, slow-blow
Voltage state 0 guaranteed <= 5 V discrete input
Voltage state 1 guaranteed 15...< 30 V discrete input
Current state 0 guaranteed 1...1.5 mA discrete input)
Current state 1 guaranteed <= 2 mA discrete input)
Discrete input voltage 20 V
Discrete input current 40 mA
Input protection type Protected against short-circuit
Output voltage 20 V line control outputs
Nominal output current 60 mA line control outputs
Switching voltage 7.5 V discrete input
Switching time 250 µs
Discrete output voltage 24 V DC
Output voltage tolerance +/- 3 %
Discrete output current > 10 mA 140 °F (60 °C) channels 1 to 3, 5 to 7, 4 and 8)
1 A 140 °F (60 °C) channels 1 to 3, 5 to 7, 4 and 8)
2 A 104 °F (40 °C) channels 1 to 3, 5 to 7, 4 and 8)
<= 9 A all channels)
Inductive load 500 mH discrete output
Maximum tungsten load <25 W discrete output
Maximum line resistance 5 kOhm discrete output
Minimum load 2 mA per channel
Maximum leakage current 1 mA 2 V at state 0 discrete output
Communication port protocol Safe Ethernet 2 RJ45 100 Mbps, 10 Mbps dual twisted pair cable, category 5D or better
Exchange mode Half duplex, full duplex, autonegotiation
Number of terminal blocks 1 line control outputs
1 power supply
3 discrete output
4 discrete input
Current consumption 14 A 24 V DC on power supply
Mounting Support 35 mm symmetrical DIN rail
Depth 3.4 in (86.5 mm)
Height 4.3 in (109 mm)
Width 8.07 in (205 mm)
Product Weight 2.9 lb(US) (1.3 kg)
XPSMF3DIO20802 Schneider Electric

Main

Characteristic Value(s)
Range of Product Preventa Safety automation
Product or Component Type Preventa safety remote mixed I/O module
Safety module name XPSMF3
Safety module application Extension of I/O capacity
Safety use category Category 4 maximum EN 954-1
Performance level e EN/ISO 13849-1
SIL 3 EN/IEC 61508
Function of module Monitoring safety actuators discrete input
Monitoring safety actuators discrete output
Monitoring safety detection discrete input
Monitoring safety dialogue discrete input
[Us] Rated Supply Voltage 24 V DC - 15...20 %
Supply SELV or PELV EN/IEC 60950
Discrete input number 20 not isolated
Discrete output number 8, not isolated
Structure type 10BASE-T/100BASE-TX

Complementary

Characteristic Value(s)
Response Time Depending on size of application
Voltage state 0 guaranteed <= 5 V discrete input
Voltage state 1 guaranteed 15...< 30 V discrete input
Current state 0 guaranteed 1.25...1.5 mA discrete input)
Current state 1 guaranteed <= 2 mA discrete input)
Discrete input voltage 20 V
Discrete input current 100 mA
Input protection type Protected against short-circuit
Switching voltage 7.5 V discrete input
Discrete output voltage 24 V DC
Output voltage tolerance +/- 2%
Discrete output current 1 A 140 °F (60 °C) channels 4 and 8)
2 A 122 °F (50 °C) channels 4 and 8)
0.5 A 140 °F (60 °C) channels 1 to 3 and 5 to 7)
<= 7 A all channels)
Minimum load 2 mA per channel
Maximum leakage current 1 mA 2 V at state 0 discrete output
Communication port protocol Safe Ethernet 2 RJ45 100 Mbps, 10 Mbps dual twisted pair cable, category 5D or better
Exchange mode Half duplex, full duplex, autonegotiation
Number of terminal blocks 1 power supply
2 discrete input
2 discrete output
Current consumption 8 A 24 V DC on power supply
Mounting Support 35 mm symmetrical DIN rail
Depth 2.6 in (66.5 mm)
Height 4.3 in (109 mm)
Width 8.1 in (207 mm)
Product Weight 2.2 lb(US) (1 kg)
XPSMF3DIO8801 Schneider Electric

Main

Characteristic Value(s)
Range of Product Preventa Safety automation
Product or Component Type Preventa safety remote mixed I/O module
Safety module name XPSMF3
Safety module application Extension of I/O capacity
Safety use category Category 4 maximum EN 954-1
Performance level e EN/ISO 13849-1
SIL 3 EN/IEC 61508
Function of module Monitoring safety actuators discrete input
Monitoring safety actuators discrete output
Monitoring safety detection discrete input
Monitoring safety dialogue discrete input
Monitoring safety dialogue discrete output
Monitoring short-circuit and line break line control outputs
[Us] Rated Supply Voltage 24 V DC - 15...20 %
Supply SELV or PELV EN/IEC 60950
Discrete input number 8 not isolated
Number of outputs 2 not isolated line control outputs
Discrete output number 10, not isolated
Structure type 10BASE-T/100BASE-TX

Complementary

Characteristic Value(s)
Response Time Depending on size of application
Associated fuse rating 10 A, slow-blow
Voltage state 0 guaranteed <= 5 V discrete input
Voltage state 1 guaranteed 15...< 30 V discrete input
Current state 0 guaranteed 1.25...1.5 mA discrete input)
Current state 1 guaranteed <= 2 mA discrete input)
Discrete input voltage 20 V
Discrete input current 100 mA
Input protection type Protected against short-circuit
Output voltage 20 V line control outputs
Nominal output current 60 mA line control outputs
Switching voltage 7.5 V discrete input
Discrete output voltage 24 V DC
Output voltage tolerance +/- 2%
Discrete output current 1 A 140 °F (60 °C) channels 1 and 2)
1 A 140 °F (60 °C) channels 4 and 8)
2 A 104 °F (40 °C) channels 4 and 8)
0.5 A 140 °F (60 °C) channels 1 to 3 and 5 to 7)
<= 7 A all channels)
Inductive load 500 mH discrete output
Maximum tungsten load <10 W, channels 1 to 3 and 5 to 7 discrete output
<25 W, channels 1 and 2 discrete output
<25 W, channels 4 and 8 discrete output
Minimum load 2 mA per channel
Maximum leakage current 1 mA 2 V at state 0 discrete output
Communication port protocol Safe Ethernet 2 RJ45 100 Mbps, 10 Mbps dual twisted pair cable, category 5D or better
Exchange mode Half duplex, full duplex, autonegotiation
Number of terminal blocks 1 power supply
2 discrete input
2 discrete output
2 line control outputs
Current consumption 8 A 24 V DC on power supply
Mounting Support 35 mm symmetrical DIN rail
Depth 2.6 in (66.5 mm)
Height 4.3 in (109 mm)
Width 6.0 in (152 mm)
Product Weight 2.2 lb(US) (1 kg)
XPSMF4000 Schneider Electric
Schneider XPSMF4000 Schneider Electric
Sale price$0.00
Sold Out

Preventa safety PLC compact - Safe Ethernet

XPSMF4002 Schneider Electric
Schneider XPSMF4002 Schneider Electric
Sale price$0.00
Sold Out

Preventa safety PLC compact - Safe Ethernet, Modbus TCP/IP

XPSMF4020 Schneider Electric
Schneider XPSMF4020 Schneider Electric
Sale price$0.00
Sold Out

Preventa safety PLC compact - Safe Ethernet, Modbus RTU

XPSMF4022 Schneider Electric
Schneider XPSMF4022 Schneider Electric
Sale price$0.00
Sold Out

Main

Characteristic Value(s)
Range of Product Preventa Safety automation
Product or Component Type Preventa safety PLC compact
Safety module name XPSMF40
Safety module application F use with numerous machine safety functions and for the protection of personel
Safety use category Category 4 maximum EN 954-1
Performance level e EN/ISO 13849-1
SIL 3 EN/IEC 61508
Structure type 10BASE-T/100BASE-TX, Modbus TCP/IP
10BASE-T/100BASE-TX, safe Ethernet

Complementary

Characteristic Value(s)
Function of module Monitoring safety actuators discrete output
Monitoring safety detection discrete input
Monitoring safety dialogue discrete input
Monitoring safety dialogue discrete output
Monitoring short-circuit and line break line control outputs
[Us] Rated Supply Voltage 24 V DC - 15...20 %
Supply SELV or PELV EN/IEC 60950
No load current 0.5 A
Protection Type 10 A internal fuse
Clock With, supplied by backup capacitor for 1 week following loss of supply
Response Time Depending on size of application
Memory description User logic 250 kB application
User logic 250 kB data
Group of channels 2 groups of 4 line control outputs
Discrete I/O number 24 configurable
Maximum discrete input number 24 not isolated
Voltage state 0 guaranteed <= 24 V discrete input
Voltage state 1 guaranteed 24...30 V discrete input
Current state 0 guaranteed <= 1.5 mA discrete input)
Current state 1 guaranteed 3.5...4.5 mA discrete input)
Discrete input voltage 20 V
Discrete input current 100 mA
Maximum input resistance 7 kOhm
Input overvoltage protection -10…35 V discrete input
Maximum discrete output number 24 not isolated
Discrete output voltage 24 V DC
Output voltage tolerance +/- 2%
Discrete output current 1 A 140 °F (60 °C) channels 4, 8, 12, 16, 20 and 24)
2 A 122 °F (50 °C) channels 4, 8, 12, 16, 20 and 24)
0.5 A 140 °F (60 °C) channels 1 to 3, 5 to 7, 9 to 11,13 to 15, 17 to 19, 21 to 23)
<= 7 A all channels)
Minimum load 2 mA per discrete output
Maximum leakage current 1 mA 2 V at state 0 discrete output
Overload protection Shutdown of outputs concerned with cyclic reconnection
Output voltage 20 V line control outputs
Nominal output current 60 mA line control outputs
Communication port protocol Safe Ethernet 2 RJ45 100 Mbps, 10 Mbps dual twisted pair cable, category 5D or better
Modbus TCP/IP 2 RJ45 100 Mbps, 10 Mbps dual twisted pair cable, category 5D or better
Modbus RTU 1 RJ45, RS485 shielded dual twisted pair cable
Exchange mode Half duplex, full duplex, autonegotiation Modbus TCP/IP
Half duplex, full duplex, autonegotiation safe Ethernet
Method of access Slave Modbus TCP/IP
Slave V0 Modbus serial
Number of addresses 122 Modbus serial
Concept Transparent Ready, Modbus TCP/IP
Web server Class A10, Modbus TCP/IP
Web services Modbus identification request, Modbus TCP/IP
Modbus TCP/IP messaging (reading/writing of data words), Modbus TCP/IP
Modbus TCP/IP server, Modbus TCP/IP
Standard 502, Modbus TCP/IP
Maximum number of connections 1 to 20, Modbus TCP/IP
Operating distance <= 300 m between station discrete input
<= 300 m between station discrete output
Number of terminal blocks 1 power supply
2 line control outputs
6 discrete input/output circuit
8 line control outputs
Connections - terminals Discrete input/output circuit captive spring terminals, 1 x 0.5 mm² AWG 20) flexible with cable end
Line control outputs captive spring terminals, 1 x 0.5 mm² AWG 20) flexible with cable end
Discrete input/output circuit captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² AWG 25...AWG 15) solid without cable end
Line control outputs captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² AWG 25...AWG 15) solid without cable end
Discrete input/output circuit captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² AWG 28...AWG 16) flexible without cable end
Line control outputs captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² AWG 28...AWG 16) flexible without cable end
Power supply captive screw clamp terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 12) flexible without cable end
Power supply captive screw clamp terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 12) solid without cable end
Discrete input/output circuit captive screw clamp terminals, 1 x 0.25...1 x 0.5 mm² AWG 23...AWG 20) flexible with cable end
Line control outputs captive screw clamp terminals, 1 x 0.25...1 x 0.5 mm² AWG 23...AWG 20) flexible with cable end
Discrete input/output circuit captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² AWG 23...AWG 15) flexible without cable end
Line control outputs captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² AWG 23...AWG 15) flexible without cable end
Power supply captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² AWG 23...AWG 14) flexible with cable end
Power supply captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² AWG 23...AWG 14) flexible without cable end
Discrete input/output circuit captive spring terminals, 1 x 0.14...1 x 1.5 mm² AWG 26...AWG 16) solid without cable end
Line control outputs captive spring terminals, 1 x 0.14...1 x 1.5 mm² AWG 26...AWG 16) solid without cable end
Discrete input/output circuit captive spring terminals, 1 x 0.14...1 x 1.5 mm² AWG 26...AWG 17) flexible without cable end
Line control outputs captive spring terminals, 1 x 0.14...1 x 1.5 mm² AWG 26...AWG 17) flexible without cable end
Power supply captive spring terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 12) flexible without cable end
Power supply captive spring terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 12) solid without cable end
Discrete input/output circuit captive spring terminals, 1 x 0.25...1 x 0.34 mm² AWG 22) flexible without cable end
Line control outputs captive spring terminals, 1 x 0.25...1 x 0.34 mm² AWG 22) flexible without cable end
Power supply captive spring terminals, 1 x 0.25...1 x 2.5 mm² AWG 23...AWG 12) flexible with cable end
Power supply captive spring terminals, 1 x 0.25...1 x 2.5 mm² AWG 23...AWG 12) flexible without cable end
Tightening torque Discrete input/output circuit 1.95…2.21 lbf.in (0.22…0.25 N.m) captive screw clamp terminals
Line control outputs 1.95…2.21 lbf.in (0.22…0.25 N.m) captive screw clamp terminals
Power supply 4.4 lbf.in (0.5 N.m) captive screw clamp terminals
Wire stripping length 0.4 in (10 mm) power supply captive screw clamp terminals
0.4 in (9 mm) discrete input/output circuit captive screw clamp terminals
0.4 in (9 mm) discrete input/output circuit captive spring terminals
0.4 in (9 mm) line control outputs captive screw clamp terminals
0.4 in (9 mm) line control outputs captive spring terminals
0.4 in (9 mm) power supply captive spring terminals
Current consumption 8 A 24 V DC on power supply
Mounting Support 35 mm symmetrical DIN rail
Depth 6.02 in (153 mm)
Height 6.0 in (151.5 mm)
Width 2.9 in (74 mm)
Product Weight 2.2 lb(US) (1 kg)
XPSMF4040 Schneider Electric
Schneider XPSMF4040 Schneider Electric
Sale price$0.00
Sold Out

Main

Characteristic Value(s)
Range of Product Preventa Safety automation
Product or Component Type Preventa safety PLC compact
Safety module name XPSMF40
Safety module application F use with numerous machine safety functions and for the protection of personel
Safety use category Category 4 maximum EN 954-1
Performance level e EN/ISO 13849-1
SIL 3 EN/IEC 61508
Structure type 10BASE-T/100BASE-TX, safe Ethernet

Complementary

Characteristic Value(s)
Function of module Monitoring safety actuators discrete output
Monitoring safety detection discrete input
Monitoring safety dialogue discrete input
Monitoring safety dialogue discrete output
Monitoring short-circuit and line break line control outputs
[Us] Rated Supply Voltage 24 V DC - 15...20 %
Supply SELV or PELV EN/IEC 60950
No load current 0.5 A
Protection Type 10 A internal fuse
Clock With, supplied by backup capacitor for 1 week following loss of supply
Response Time Depending on size of application
Memory description User logic 250 kB application
User logic 250 kB data
Group of channels 2 groups of 4 line control outputs
Discrete I/O number 24 configurable
Maximum discrete input number 24 not isolated
Voltage state 0 guaranteed <= 24 V discrete input
Voltage state 1 guaranteed 24...30 V discrete input
Current state 0 guaranteed <= 1.5 mA discrete input)
Current state 1 guaranteed 3.5...4.5 mA discrete input)
Discrete input voltage 20 V
Discrete input current 100 mA
Maximum input resistance 7 kOhm
Input overvoltage protection -10…35 V discrete input
Maximum discrete output number 24 not isolated
Discrete output voltage 24 V DC
Output voltage tolerance +/- 2%
Discrete output current 1 A 140 °F (60 °C) channels 4, 8, 12, 16, 20 and 24)
2 A 122 °F (50 °C) channels 4, 8, 12, 16, 20 and 24)
0.5 A 140 °F (60 °C) channels 1 to 3, 5 to 7, 9 to 11,13 to 15, 17 to 19, 21 to 23)
<= 7 A all channels)
Minimum load 2 mA per discrete output
Maximum leakage current 1 mA 2 V at state 0 discrete output
Overload protection Shutdown of outputs concerned with cyclic reconnection
Output voltage 20 V line control outputs
Nominal output current 60 mA line control outputs
Communication port protocol Safe Ethernet 2 RJ45 100 Mbps, 10 Mbps dual twisted pair cable, category 5D or better
Profibus 1 SUB-D 9-pin female, RS485 shielded dual twisted pair cable
Exchange mode Half duplex, full duplex, autonegotiation safe Ethernet
Method of access Slave V0 Profibus
Operating distance <= 300 m between station discrete input
<= 300 m between station discrete output
Number of terminal blocks 1 power supply
2 line control outputs
6 discrete input/output circuit
8 line control outputs
Connections - terminals Discrete input/output circuit captive spring terminals, 1 x 0.5 mm² AWG 20) flexible with cable end
Line control outputs captive spring terminals, 1 x 0.5 mm² AWG 20) flexible with cable end
Discrete input/output circuit captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² AWG 25...AWG 15) solid without cable end
Line control outputs captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² AWG 25...AWG 15) solid without cable end
Discrete input/output circuit captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² AWG 28...AWG 16) flexible without cable end
Line control outputs captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² AWG 28...AWG 16) flexible without cable end
Power supply captive screw clamp terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 12) flexible without cable end
Power supply captive screw clamp terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 12) solid without cable end
Discrete input/output circuit captive screw clamp terminals, 1 x 0.25...1 x 0.5 mm² AWG 23...AWG 20) flexible with cable end
Line control outputs captive screw clamp terminals, 1 x 0.25...1 x 0.5 mm² AWG 23...AWG 20) flexible with cable end
Discrete input/output circuit captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² AWG 23...AWG 15) flexible without cable end
Line control outputs captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² AWG 23...AWG 15) flexible without cable end
Power supply captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² AWG 23...AWG 14) flexible with cable end
Power supply captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² AWG 23...AWG 14) flexible without cable end
Discrete input/output circuit captive spring terminals, 1 x 0.14...1 x 1.5 mm² AWG 26...AWG 16) solid without cable end
Line control outputs captive spring terminals, 1 x 0.14...1 x 1.5 mm² AWG 26...AWG 16) solid without cable end
Discrete input/output circuit captive spring terminals, 1 x 0.14...1 x 1.5 mm² AWG 26...AWG 17) flexible without cable end
Line control outputs captive spring terminals, 1 x 0.14...1 x 1.5 mm² AWG 26...AWG 17) flexible without cable end
Power supply captive spring terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 12) flexible without cable end
Power supply captive spring terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 12) solid without cable end
Discrete input/output circuit captive spring terminals, 1 x 0.25...1 x 0.34 mm² AWG 22) flexible without cable end
Line control outputs captive spring terminals, 1 x 0.25...1 x 0.34 mm² AWG 22) flexible without cable end
Power supply captive spring terminals, 1 x 0.25...1 x 2.5 mm² AWG 23...AWG 12) flexible with cable end
Power supply captive spring terminals, 1 x 0.25...1 x 2.5 mm² AWG 23...AWG 12) flexible without cable end
Tightening torque Discrete input/output circuit 1.95…2.21 lbf.in (0.22…0.25 N.m) captive screw clamp terminals
Line control outputs 1.95…2.21 lbf.in (0.22…0.25 N.m) captive screw clamp terminals
Power supply 4.4 lbf.in (0.5 N.m) captive screw clamp terminals
Wire stripping length 0.4 in (10 mm) power supply captive screw clamp terminals
0.4 in (9 mm) discrete input/output circuit captive screw clamp terminals
0.4 in (9 mm) discrete input/output circuit captive spring terminals
0.4 in (9 mm) line control outputs captive screw clamp terminals
0.4 in (9 mm) line control outputs captive spring terminals
0.4 in (9 mm) power supply captive spring terminals
Current consumption 8 A 24 V DC on power supply
Mounting Support 35 mm symmetrical DIN rail
Depth 6.02 in (153 mm)
Height 6.0 in (151.5 mm)
Width 2.9 in (74 mm)
Product Weight 2.2 lb(US) (1 kg)
XPSMP11123 Schneider Electric
Schneider XPSMP11123 Schneider Electric
Sale price $997.50
Only 1 unit left

This XPSMP safety contoller can handle 2 independent safety functions. This safety controller with pre-defined functions meets the requirements of PL e/Category 4 conforming EN ISO 13849-1 and SILCL 3 conforming to EN/IEC 61508 and EN/IEC 62061. It enables two independent safety functions (selected from a choice of 15 pre-defined configurations) to be performed using the same product. It complies with the most stringent functional safety requirements thanks to multiple configurable safety functions. It has additional solid-state output for communication with PLCs about safety status of your process.

Main

Characteristic Value(s)
Range of Product Preventa Safety automation
Product or Component Type Safety controller with pre-defined function
Safety module name XPSMP
Safety module application 2 independent functions
Safety use category Category 4 maximum EN/IEC 60954-1
Type of start Automatic or unmonitored 1)
Automatic or unmonitored 10)
Automatic or unmonitored 11)
Automatic or unmonitored 14)
Automatic or unmonitored 3)
Automatic or unmonitored 5)
Automatic or unmonitored 7)
Monitored 12)
Monitored 13)
Monitored 15)
Monitored 2)
Monitored 4)
Monitored 6)
Monitored 8)
Monitored 9)
Checks Configuration 10)
Configuration 13)
Configuration 3)
Configuration 4)
Configuration 5)
Configuration 6)
Configuration 9)
Standards EN/IEC 60947-1 + A11
EN/IEC 60947-5-1
EN/IEC 60204-1
DIN V VDE 801 + A1
Product Certifications UL
CSA
BIA
[Us] Rated Supply Voltage 24 V DC - 20...20 %
Connections - terminals Captive screw clamp terminals flexible 0.14...0.75 mm² without cable end, 2 wires
Captive screw clamp terminals solid 0.14...0.75 mm² without cable end, 2 wires
Captive screw clamp terminals flexible 0.14...2.5 mm² without cable end, 1 wire
Captive screw clamp terminals solid 0.14...2.5 mm² without cable end, 1 wire
Captive screw clamp terminals flexible 0.25...1 mm² with cable end, without bezel, 2 wires
Captive screw clamp terminals flexible 0.25...1.5 mm² with cable end, with bezel, 1 wire
Captive screw clamp terminals flexible 0.25...2.5 mm² with cable end, without bezel, 1 wire
Captive screw clamp terminals flexible 0.5...1.5 mm² with cable end, with double bezel, 2 wires
Safety level Can reach PL e/category 4 EN/ISO 13849-1
Can reach SIL 3 EN/IEC 62061

Complementary

Characteristic Value(s)
Function of module 0 functions disabled (factory setting)
1 emergency stop monitoring 1-channel wiring, category 2
10 enabling grip switch monitoring (3-position switch), category 4
11 sensing mat and edges monitoring, category 3
12 sensing mat and edges monitoring, category 3
13 relay output safety light curtain monitoring, category 4
14 coded magnetic switch monitoring, category 4
15 coded magnetic switch monitoring, category 4
2 emergency stop monitoring 1-channel wiring, category 2
3 emergency stop monitoring 2-channel wiring, or guard monitoring, category 4
4 emergency stop monitoring 2-channel wiring, or guard monitoring, category 4
5 emergency stop monitoring 2-channel wiring, or guard monitoring, category 4
6 emergency stop monitoring 2-channel wiring, or guard monitoring, category 4
7 emergency stop monitoring 2-channel wiring, or guard monitoring, category 4
8 emergency stop monitoring 2-channel wiring, or guard monitoring, category 4
9 guard monitoring for injection presses and blowing machines, category 4
Synchronisation time between inputs 0.5 s 13)
1.5 s 14)
1.5 s 15)
1.5 s 5)
1.5 s 6)
1.5 s 9)
Unlimited 3)
Unlimited 4)
Unlimited 7)
Unlimited 8)
Power Consumption in W 5 W
Input protection type Internal, electronic
[Uc] control circuit voltage 24 V
Maximum line resistance 100 Ohm <6561.7 ft (2000 m)
Number of safety circuits 3 NO relays per function (6 NO total), volt-free
Number of additional circuits 3 solid state outputs
Breaking capacity 180 VA holding AC-15 C300 relay output
1800 VA inrush AC-15 C300 relay output
Breaking capacity 20 mA 24 V static output circuit
1.5 A 24 V DC-13)50 ms relay output
Output thermal current 2 A for 1 output and 4 A for the other 2 outputs relay
3.3 A for all 3 outputs relay simultaneously
6 A for 1 output and 2 A for the other 2 outputs relay
[Ith] conventional free air thermal current 20 A
Associated fuse rating 4 A gG relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200
6 A fast blow relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200
Minimum output current 10 mA relay output
Minimum output voltage 17 V relay output
Maximum response time on input open 30 ms
[Ui] rated insulation voltage 300 V 2)EN/IEC 60947-5-1, DIN VDE 0110 parts 1 & 2
[Uimp] rated impulse withstand voltage 4 kV III EN/IEC 60947-5-1, DIN VDE 0110 parts 1 & 2
Local signalling 12 LEDs
Mounting Support 35 mm symmetrical DIN rail
Depth 4.5 in (114 mm)
Height 3.9 in (99 mm)
Width 1.8 in (45 mm)
Product Weight 0.71 lb(US) (0.32 kg)
XPSMP11123P Schneider Electric
Schneider XPSMP11123P Schneider Electric
Sale price $629.99
Only 3 units left

module XPS-MP - 2 independent functions - 24 V DC

Recently viewed