keyence Stock Image
Keyence SI-F10U Keyence
Sale price$0.00
Sold Out

Specifications

Model

SI-F10U

Type

Long distance type Spectrum unit

Measurement range

11.3 to 12.35 mm 0.44" to 0.49" *1

Light source

Infrared SLD Central wavelength 820 nm Output 0.6 mW Class 1 Laser product (IEC60825-1/FDA (CDRH) Part 1040.10*2)

Spot diameter

ø40 µm ø0.001575"*3

Linearity

±0.3 µm ±0.000012" *4

Resolution

0.01 µm *5

Sampling cycle

200 µs

Light source for guide

Red semiconductor laser Wavelength 655 nm Output 0.1 mW Class 1 Laser product (IEC60825-1/FDA (CDRH) Part 1040.10*2)

LED display

Target near center of measurement range: green lights. Target within measurement range: orange lights. Target outside measurement range: Flashes orange.

Temperature fluctuation

0.01% of F.S./°C

Environmental resistance

Enclosure rating

-

Ambient light

Incandescent lamp or Fluorescent lamp: 10,000 lux max.

Ambient temperature

0 to +35 °C 32 to 95 °F

Relative humidity

35 to 80 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 0.5 mm 0.02", 2 hours in each of the X, Y, and Z directions

Material

Polycarbonate

Weight

Approx. 1 kg

*1 Indicates distance from the front of the sensor head. For long distance type sensor heads there is an individual difference of up to ±0.2 mm ±0.01".
*2 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice.
*3 Indicates the minimum beam spot diameter within the measurement range.
*4 This value is obtained when the measurement target is a glass plate with the number of averaging measurements set to 256.
*5 This value is obtained by measuring a glass plate surface located at the center of the measurement range with the number of averaging measurements set to 4,096.

keyence Stock Image
Keyence SI-F01U3 Keyence
Sale price$0.00
Sold Out

Specifications

Model

SI-F01U3

Measurement range

0.05 to 1.1 mm 0.002 to 0.04" *1

Light source

Infrared SLD Central wavelength 820 nm Output 0.6 mW Class 1 Laser product (IEC60825-1/FDA (CDRH) Part 1040.10*2)

Spot diameter

ø20 µm ø0.000787"*3

Linearity

±0.3 µm ±0.000012"*4

Resolution

0.25 µm 0.00000984"*5

Sampling cycle

200 µs

Light source for guide

Red semiconductor laser Wavelength 650 nm Output 0.1 mW Class 1 Laser product (IEC60825-1/FDA (CDRH) Part 1040.10*2)

LED display

Target near center of measurement range: green lights. Target within measurement range: orange lights. Target outside measurement range: Flashes orange.

Temperature fluctuation

0.01% of F.S./°C

Environmental resistance

Ambient light

Incandescent lamp or Fluorescent lamp: 10,000 lux max.

Ambient temperature

0 to +35 °C 32 to 95 °F

Relative humidity

35 to 80 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 0.5 mm 0.02", 2 hours in each of the X, Y, and Z directions

Material

Polycarbonate

Weight

Approx. 1 kg

*1 Indicates distance from the front of the sensor head. For long distance type sensor heads there is an individual difference of up to ±0.2 mm ±0.01".
*2 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice.
*3 Indicates the minimum beam spot diameter within the measurement range.
*4 This value is obtained when the measurement target is a glass plate with the number of averaging measurements set to 256.
*5 This value is obtained by measuring a glass plate surface located at the center of the measurement range with the number of averaging measurements set to 4,096.

keyence Stock Image
Keyence SI-F01U Keyence
Sale price$0.00
Sold Out

Specifications

Model

SI-F01U

Type

Micro-head type Spectrum unit

Measurement range

0.05 to 1.1 mm 0.002 to 0.04" *1

Light source

Infrared SLD Central wavelength 820 nm Output 0.6 mW Class 1 Laser product (IEC60825-1/FDA (CDRH) Part 1040.10*2)

Spot diameter

ø20 µm ø0.000787"*3

Linearity

±0.2 µm ±0.000008" *4

Resolution

0.001 µm *5

Sampling cycle

200 µs

Light source for guide

Red semiconductor laser Wavelength 655 nm Output 0.1 mW Class 1 Laser product (IEC60825-1/FDA (CDRH) Part 1040.10*2)

LED display

Target near center of measurement range: green lights. Target within measurement range: orange lights. Target outside measurement range: Flashes orange.

Temperature fluctuation

0.01% of F.S./°C

Environmental resistance

Enclosure rating

-

Ambient light

Incandescent lamp or Fluorescent lamp: 10,000 lux max.

Ambient temperature

0 to +35 °C 32 to 95 °F

Relative humidity

35 to 80 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 0.5 mm 0.02", 2 hours in each of the X, Y, and Z directions

Material

Polycarbonate

Weight

Approx. 1 kg

*1 Indicates distance from the front of the sensor head. For long distance type sensor heads there is an individual difference of up to ±0.2 mm ±0.01".
*2 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice.
*3 Indicates the minimum beam spot diameter within the measurement range.
*4 This value is obtained when the measurement target is a glass plate with the number of averaging measurements set to 256.
*5 This value is obtained by measuring a glass plate surface located at the center of the measurement range with the number of averaging measurements set to 4,096.

keyence Stock Image
Keyence SI-FA103 Keyence
Sale price$0.00
Sold Out

Specifications

Model

SI-FA103

Separate type

Type

Expansion controller*1

No. of connectable spectrum units

1

Display

Minimum display unit

N/A

Display range

Display cycle

Terminal block

Laser remote interlock input

N/A*2

TIMING1 input

RESET1 input

Auto-zero1 input

Laser control input

Analog voltage output

±10 V x 1 outputs, Output impedance: 100 Ω*2

Analog current output

4 to 20 mA x 1 output, Maximum load resistance: 350 Ω*2

Alarm output

N/A*2

General comparator output

Expansion connector

TIMING2 input

RESET input

Auto-zero input

Program switch input

Alarm output

Comparator/ binary output

Binary output

Strobe output

Binary selection output

Binary selection input

RS-232C interface

N/A

USB interface

Ethernet interface

Major functions

12 Out simultaneous measurement
calculation, average, filter, scaling measurement, measured value alarm, tolerance setting, auto-zero, data storage, light monitor, 8-program memory,
interferometer mode, mask, connection of setting support software, etc.

Environmental resistance

Ambient temperature

0 to +50 °C 32 to 122 °F*3

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 0.5 mm 0.02", 2 hours in each of the X, Y, and Z directions

Weight

Approx. 300 g

*1 Up to four expansion controllers can be connected to the main controller.
*2 • NPN open-collector output rating: 50 mA max. (40 V max.), Residual voltage: 0.5 V max.
• Non-voltage input rating: ON voltage: 1 V max., OFF current: 0.6 mA max.
• Part of the input/output circuit of the SI Series is internally common. Be careful that no potential difference is generated between the internally common terminals due to the potential difference between the cables/external
devices. For details, refer to "Precautions on wiring".
*3 When two or more expansion controllers are connected, the ambient temperature is 0 to +40 °C 32 to 104 °F.

keyence Stock Image
Keyence SI-FA100 Keyence
Sale price$0.00
Sold Out

Specifications

Model

SI-FA100*1

Separate type

SI-FA100

Type

Expansion controller*2

No. of connectable spectrum units

1

Display

Minimum display unit

N/A

Display range

Display cycle

Terminal block

Laser remote interlock input

N/A*3

TIMING1 input

RESET1 input

Auto-zero1 input

Laser control input

Analog voltage output

±10 V x 1 output, Output impedance: 100 Ω*3

Analog current output

4 to 20 mA x 1 output, Maximum load resistance: 350 Ω*3

Alarm output

N/A*3

General comparator output

Expansion connector

TIMING2 input

RESET input

Auto-zero input

Program switch input

Alarm output

Comparator/ binary output

Binary output

Strobe output

Binary selection output

Binary selection input

RS-232C interface

N/A

USB interface

Ethernet interface

Major functions

12 Out simultaneous measurement
calculation, average, filter, scaling measurement, measured value alarm, tolerance setting, auto-zero, data storage, light monitor, 8-program memory,
interferometer mode, mask, connection of setting support software, etc.

Rating

Power voltage

Supplied from the main controller

Current consumption

Environmental resistance

Ambient temperature

0 to +50 °C 32 to 122 °F*4

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 0.5 mm 0.02", 2 hours in each of the X, Y, and Z directions

Weight

Approx. 300 g

*1 The SI-F1003 can be used independently, The measured value display and setting change can be done with the display panel(SI-FD500) and setup support software(SI-H3).
*2 Up to four expansion controllers can be connected to the main controller.
*3 • NPN open-collector output rating: 50 mA max. (40 V max.), Residual voltage: 0.5 V max.
• Non-voltage input rating: ON voltage: 1 V max., OFF current: 0.6 mA max.
• Part of the input/output circuit of the SI Series is internally common. Be careful that no potential difference is generated between the internally common terminals due to the potential difference between the cables/external
devices. For details, refer to "Precautions on wiring".
*4 When two or more expansion controllers are connected, the ambient temperature is 0 to +40 °C 32 to 104 °F.

keyence Stock Image
Keyence SI-FD500 Keyence
Sale price$0.00
Sold Out

Specifications

Model

SI-FD500

Type

Main Controller Separate type*1

No. of connectable spectrum units

2

Display

Minimum display unit

0.001 µm

Display range

±999.999 µm to ±9999.99 mm (7 settings selectable)

Display cycle

10 times/sec.

Terminal block

Laser remote interlock input

Non-voltage input*2

TIMING1 input

RESET1 input

Auto-zero1 input

Laser control input

Analog voltage output

±10 V x 2 outputs, Output impedance: 100 Ω*2

Analog current output

4 to 20 mA x 2 outputs, Maximum load resistance: 350 Ω*2

Alarm output

NPN open-collector output (N.C.)*2

General comparator output

NPN open-collector output*2

Expansion connector

TIMING2 input

Non-voltage input*2

RESET input

Auto-zero input

Program switch input

Non-voltage input x 3 inputs*2

Alarm output

NPN open-collector output (N.C.)*2

Comparator/ binary output

Binary output

Measured value data output (21 bits) OUT selectable NPN open-collector output*2

Strobe output

NPN open-collector output*2

Binary selection output

Binary selection input

Non-voltage input*2

RS-232C interface

Measured data output and control input/output (Baud rate selectable to 115,200 bps max.)

USB interface

USB 2.0 high speed compliant (USB 1.1 Full-SPEED compatible)

Ethernet interface

100Base-TX/10Base-T

Major functions

12 Out simultaneous measurement
calculation, average, filter, scaling measurement, measured value alarm, tolerance setting, auto-zero, data storage, light monitor, 8-program memory,
interferometer mode, mask, connection of setting support software, etc.

Rating

Power voltage

24 VDC ±10 %, Ripple (P-P) 10 % or less

Current consumption

One head connected: 0.6 A or less. Six heads connected: 1.5 A or less.

Environmental resistance

Ambient temperature

0 to +50 °C 32 to 122 °F*3

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 0.5 mm 0.02", 2 hours in each of the X, Y, and Z directions

Weight

Approx. 600 g

*1 The SI-F1001 can be used independently. The measured value display and setting change can be done with the display panel (SI-FD500) and setup support software (SI-H1).
*2 • NPN open-collector output rating: 50 mA max. (40 V max.), Residual voltage: 0.5 V max.
• Non-voltage input rating: ON voltage: 1 V max., OFF current: 0.6 mA max.
• Part of the input/output circuit of the SI Series is internally common. Be careful that no potential difference is generated between the internally common terminals due to the potential difference between the cables/external
devices. For details, refer to "Precautions on wiring".
*3 When two or more expansion controllers are connected, the ambient temperature is 0 to +40 °C 32 to 104 °F.

keyence Stock Image
Keyence SI-F80 Keyence
Sale price$0.00
Sold Out

Specifications

Model

SI-F80

Type

Thickness measurement type Sensor head

Measurement range

0.05 to 1.1 mm 0.002" to 0.04" *1
(Possible detection distance : 80 to 81.1 mm 3.15" to 3.19")

Light source

Infrared SLD Central wavelength 820 nm Output 0.6 mW Class 1 Laser product (IEC60825-1/FDA (CDRH) Part 1040.10*2)

Spot diameter

ø20 µm ø0.000787"*3

Linearity

±0.3 µm ±0.000012"*4

Resolution

0.25 µm 0.00000984"*5

Sampling cycle

200 µs

Light source for guide

Red semiconductor laser Wavelength 655 nm Output 0.1 mW Class 1 Laser product (IEC60825-1/FDA (CDRH) Part 1040.10*2)

LED display

Target near center of measurement range: green lights. Target within measurement range: orange lights. Target outside measurement range: Flashes orange.

Temperature fluctuation

0.01% of F.S./°C

Environmental resistance

Enclosure rating

IP64

Ambient light

Incandescent lamp or Fluorescent lamp: 10,000 lux max.

Ambient temperature

0 to +50 °C 32 to 122 °F

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

SUS

Material

Sensor head

Spectrum unit

Polycarbonate

Weight

Approx. 39 g (including cable)

*1 The thickness measurement type sensor head displays the measurement range for the distance between plates of glass. Ensure that the measurement target is within the possible detection distance range.
*2 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice.
*3 Indicates the minimum beam spot diameter within the measurement range.
*4 This value is obtained by measuring the gap between two glass plates with the number of averaging measurements set to 256.
*5 This value is obtained by measuring a glass plate surface located at the center of the measurement range with the number of averaging measurements set to 4,096.

keyence Stock Image
Keyence SI-F10 Keyence
Sale price$0.00
Sold Out

Specifications

Model

SI-F10

Type

Long distance type Sensor head

Measurement range

11.3 to 12.35 mm 0.44" to 0.49" *1

Light source

Infrared SLD Central wavelength 820 nm Output 0.6 mW Class 1 Laser product (IEC60825-1/FDA (CDRH) Part 1040.10*2)

Spot diameter

ø40 µm ø0.001575"*3

Linearity

±0.3 µm ±0.000012"*4

Resolution

0.25 µm 0.00000984"*5

Sampling cycle

200 µs

Light source for guide

Red semiconductor laser Wavelength 655 nm Output 0.1 mW Class 1 Laser product (IEC60825-1/FDA (CDRH) Part 1040.10*2)

LED display

Target near center of measurement range: green lights. Target within measurement range: orange lights. Target outside measurement range: Flashes orange.

Temperature fluctuation

0.01% of F.S./°C

Environmental resistance

Enclosure rating

IP64

Ambient light

Incandescent lamp or Fluorescent lamp: 10,000 lux max.

Ambient temperature

0 to +40 °C 32 to 104 °F

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

SUS

Material

Sensor head

Spectrum unit

Polycarbonate

Weight

Approx. 38 g (including cable)

*1 Indicates distance from the front of the sensor head. For long distance type sensor heads there is an individual difference of up to ±0.2 mm ±0.01".
*2 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice.
*3 Indicates the minimum beam spot diameter within the measurement range.
*4 This value is obtained when the measurement target is a glass plate with the number of averaging measurements set to 256.
*5 This value is obtained by measuring a glass plate surface located at the center of the measurement range with the number of averaging measurements set to 4,096.

keyence Stock Image
Keyence SI-F01 Keyence
Sale price$0.00
Sold Out

Specifications

Model

SI-F01

Type

Micro-head type Sensor head

Measurement range

0.05 to 1.1 mm 0.002" to 0.04" *1

Light source

Infrared SLD Central wavelength 820 nm Output 0.6 mW Class 1 Laser product (IEC60825-1/FDA (CDRH) Part 1040.10*2)

Spot diameter

ø20 µm ø0.000787"*3

Linearity

±0.3 µm ±0.000012"*4

Resolution

0.25 µm 0.00000984"*5

Sampling cycle

200 µs

Light source for guide

Red semiconductor laser Wavelength 655 nm Output 0.1 mW Class 1 Laser product (IEC60825-1/FDA (CDRH) Part 1040.10*2)

LED display

Target near center of measurement range: green lights. Target within measurement range: orange lights. Target outside measurement range: Flashes orange.

Temperature fluctuation

0.01% of F.S./°C

Environmental resistance

Enclosure rating

IP67

Ambient light

Incandescent lamp or Fluorescent lamp: 10,000 lux max.

Ambient temperature

0 to +85 °C 32 to 185 °F

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

SUS

Material

Sensor head

Spectrum unit

Polycarbonate

Weight

Approx. 24 g (including cable)

*1 Indicates distance from the front of the sensor head. For long distance type sensor heads there is an individual difference of up to ±0.2 mm ±0.01".
*2 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice.
*3 Indicates the minimum beam spot diameter within the measurement range.
*4 This value is obtained when the measurement target is a glass plate with the number of averaging measurements set to 256.
*5 This value is obtained by measuring a glass plate surface located at the center of the measurement range with the number of averaging measurements set to 4,096.

keyence Stock Image
Keyence SI-F1003V Keyence
Sale price$0.00
Sold Out

Specifications

Model

SI-F1003V

Separate type

SI-F1003/SI-FD500

Type

Built-in main controller type

No. of connectable spectrum units

2

Display

Minimum display unit

0.001 µm

Display range

±999.999 µm to ±9999.99 mm (7 settings selectable)

Display cycle

10 times/sec.

Terminal block

Laser remote interlock input

Non-voltage input*1

TIMING1 input

RESET1 input

Auto-zero1 input

Laser control input

Analog voltage output

±10 V x 2 outputs, Output impedance: 100 Ω*1

Analog current output

4 to 20 mA x 2 outputs, Maximum load resistance: 350 Ω*1

Alarm output

NPN open-collector output (N.C.)*1

General comparator output

NPN open-collector output*1

Expansion connector

TIMING2 input

Non-voltage input*1

RESET input

Auto-zero input

Program switch input

Non-voltage input x 3 inputs*1

Alarm output

NPN open-collector output (N.C.)*1

Comparator/ binary output

Binary output

Measured value data output (21 bits) OUT selectable NPN open-collector output*1

Strobe output

NPN open-collector output*1

Binary selection output

Binary selection input

Non-voltage input*1

RS-232C interface

Measured data output and control input/output (Baud rate selectable to 115,200 bps max.)

USB interface

USB 2.0 high speed compliant (USB 1.1 Full-SPEED compatible)

Ethernet interface

100Base-TX/10Base-T

Major functions

12 Out simultaneous measurement
calculation, average, filter, scaling measurement, measured value alarm, tolerance setting, auto-zero, data storage, light monitor, 8-program memory,
interferometer mode, mask, connection of setting support software, etc.

Rating

Power voltage

24 VDC ±10 %, Ripple (P-P) 10 % or less

Current consumption

One head connected: 0.6 A or less. Six heads connected: 1.5 A or less.

Environmental resistance

Ambient temperature

0 to +50 °C 32 to 122 °F*2

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 0.5 mm 0.02", 2 hours in each of the X, Y, and Z directions

Weight

Approx. 600 g

*1 • NPN open-collector output rating: 50 mA max. (40 V max.), Residual voltage: 0.5 V max.
• Non-voltage input rating: ON voltage: 1 V max., OFF current: 0.6 mA max.
• Part of the input/output circuit of the SI Series is internally common. Be careful that no potential difference is generated between the internally common terminals due to the potential difference between the cables/external
devices. For details, refer to "Precautions on wiring".
*2 When two or more expansion controllers are connected, the ambient temperature is 0 to +40 °C 32 to 104 °F.

keyence Stock Image
Keyence SI-F1003 Keyence
Sale price $1,308.18
Only 2 units left

Specifications

Model

SI-F1003*1

Type

Main Controller Separate type*2

No. of connectable spectrum units

2

Display

Minimum display unit

0.001 µm

Display range

±999.999 µm to ±9999.99 mm (7 settings selectable)

Display cycle

10 times/sec

Terminal block

Laser remote interlock input

Non-voltage or voltage input *3.*4

TIMING1 input

RESET1 input

Auto-zero1 input

Laser control input

Analog voltage output

±10 V x 2 outputs, Output impedance: 100 Ω*4

Analog current output

4 to 20 mA x 2 outputs, Maximum load resistance: 350 Ω*4

Alarm output

NPN open-collector output (N.C.)*4

General comparator output

NPN open-collector output *5*4

Expansion connector

TIMING2 input

Non-voltage or voltage input *3.*4

RESET input

Auto-zero input

Program switch input

Non-voltage input x 3 inputs*4

Alarm output

NPN open-collector output (N.C.)*4

Comparator/ binary output

Binary output

Measured value data output (21 bits) OUT selectable NPN open-collector output*4

Strobe output

NPN open-collector output *5*4

Binary selection output

Binary selection input

Non-voltage or voltage input *3.*4

RS-232C interface

Measured data output and control input/output (Maximum baud rate: 115200 bps, selectable)

USB interface

In conformity with USB Revision 2.0 HI-SPEED (USB 1.1 Full-SPEED compatible)

Ethernet interface

100BASE-TX/10BASE-T

Major functions

12 Out simultaneous measurementcalculation, average, filter, scaling measurement, measured value alarm, tolerance setting, auto-zero, data storage, light monitor, 8-program memory,interferometer mode, mask, connection of setting support software, etc.

Rating

Power voltage

24 VDC ±10 %, Ripple (P-P) 10 % or less

Current consumption

One head connected: 0.6 A or less. Six heads connected: 1.5 A or less.

Environmental resistance

Ambient temperature

0 to +50 °C 32 to 122 °F*6

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 0.5 mm 0.02", 2 hours in each of the X, Y, and Z directions

Weight

Approx. 600 g

*1 The SI-F1003 can be used independently, The measured value display and setting change can be done with the display panel(SI-FD500) and setup support software(SI-H3).
*2 The SI-F1001 can be used independently. The measured value display and setting change can be done with the display panel (SI-FD500) and setup support software (SI-H1).
*3 (NPN model) The rating of non-voltage input: 1 V or less ON voltage, 0.6 mA or less OFF current. (PNP model) The rating of voltage input: 10.2 V or more ON voltage (26.4 V max.) 0.6 mA or less OFFcurrent.
*4 • NPN open-collector output rating: 50 mA max. (40 V max.), Residual voltage: 0.5 V max.
• Non-voltage input rating: ON voltage: 1 V max., OFF current: 0.6 mA max.
• Part of the input/output circuit of the SI Series is internally common. Be careful that no potential difference is generated between the internally common terminals due to the potential difference between the cables/external
devices. For details, refer to "Precautions on wiring".
*5 The rating of the NPN open-collector: 50 mA max. (40 V max.), residual voltage of 0.5 V max. The rating of the PNP open collector: 50 mA max. (30 V max.), residual voltage of 0.5 V max.
*6 When two or more expansion controllers are connected, the ambient temperature is 0 to +40 °C 32 to 104 °F.

keyence Stock Image
Keyence SI-F1001V Keyence
Sale price$0.00
Sold Out

Specifications

Model

SI-F1001V

Separate type

SI-F1001/SI-FD500

Type

Built-in main controller type

No. of connectable spectrum units

2

Display

Minimum display unit

0.001 µm

Display range

±999.999 µm to ±9999.99 mm (7 settings selectable)

Display cycle

10 times/sec.

Terminal block

Laser remote interlock input

Non-voltage input*1

TIMING1 input

RESET1 input

Auto-zero1 input

Laser control input

Analog voltage output

±10 V x 2 outputs, Output impedance: 100 Ω*1

Analog current output

4 to 20 mA x 2 outputs, Maximum load resistance: 350 Ω*1

Alarm output

NPN open-collector output (N.C.)*1

General comparator output

NPN open-collector output*1

Expansion connector

TIMING2 input

Non-voltage input*1

RESET input

Auto-zero input

Program switch input

Non-voltage input x 3 inputs*1

Alarm output

NPN open-collector output (N.C.)*1

Comparator/ binary output

Binary output

Measured value data output (21 bits) OUT selectable NPN open-collector output*1

Strobe output

NPN open-collector output*1

Binary selection output

Binary selection input

Non-voltage input*1

RS-232C interface

Measured data output and control input/output (Baud rate selectable to 115,200 bps max.)

USB interface

USB 2.0 high speed compliant (USB 1.1 Full-SPEED compatible)

Ethernet interface

100Base-TX/10Base-T

Major functions

12 Out simultaneous measurement
calculation, average, filter, scaling measurement, measured value alarm, tolerance setting, auto-zero, data storage, light monitor, 8-program memory,
interferometer mode, mask, connection of setting support software, etc.

Rating

Power voltage

24 VDC ±10 %, Ripple (P-P) 10 % or less

Current consumption

One head connected: 0.6 A or less. Six heads connected: 1.5 A or less.

Environmental resistance

Ambient temperature

0 to +50 °C 32 to 122 °F*2

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 0.5 mm 0.02", 2 hours in each of the X, Y, and Z directions

Weight

Approx. 600 g

*1 • NPN open-collector output rating: 50 mA max. (40 V max.), Residual voltage: 0.5 V max.
• Non-voltage input rating: ON voltage: 1 V max., OFF current: 0.6 mA max.
• Part of the input/output circuit of the SI Series is internally common. Be careful that no potential difference is generated between the internally common terminals due to the potential difference between the cables/external
devices. For details, refer to "Precautions on wiring".
*2 When two or more expansion controllers are connected, the ambient temperature is 0 to +40 °C 32 to 104 °F.

keyence Stock Image
Keyence SI-F1001 Keyence
Sale price$0.00
Sold Out

Specifications

Model

SI-F1001*1

Type

Main Controller Separate type*2

No. of connectable spectrum units

2

Display

Minimum display unit

0.001 µm

Display range

±999.999 µm to ±9999.99 mm (7 settings selectable)

Display cycle

10 times/sec.

Terminal block

Laser remote interlock input

Non-voltage input*3

TIMING1 input

RESET1 input

Auto-zero1 input

Laser control input

Analog voltage output

±10 V x 2 outputs, Output impedance: 100 Ω*3

Analog current output

4 to 20 mA x 2 outputs, Maximum load resistance: 350 Ω*3

Alarm output

NPN open-collector output (N.C.)*3

General comparator output

NPN open-collector output*3

Expansion connector

TIMING2 input

Non-voltage input*3

RESET input

Auto-zero input

Program switch input

Non-voltage input x 3 inputs*3

Alarm output

NPN open-collector output (N.C.)*3

Comparator/ binary output

Binary output

Measured value data output (21 bits) OUT selectable NPN open-collector output*3

Strobe output

NPN open-collector output*3

Binary selection output

Binary selection input

Non-voltage input*3

RS-232C interface

Measured data output and control input/output (Baud rate selectable to 115,200 bps max.)

USB interface

USB 2.0 high speed compliant (USB 1.1 Full-SPEED compatible)

Ethernet interface

100Base-TX/10Base-T

Major functions

12 Out simultaneous measurement
calculation, average, filter, scaling measurement, measured value alarm, tolerance setting, auto-zero, data storage, light monitor, 8-program memory,
interferometer mode, mask, connection of setting support software, etc.

Rating

Power voltage

24 VDC ±10 %, Ripple (P-P) 10 % or less

Current consumption

One head connected: 0.6 A or less. Six heads connected: 1.5 A or less.

Environmental resistance

Ambient temperature

0 to +50 °C 32 to 122 °F*4

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 0.5 mm 0.02", 2 hours in each of the X, Y, and Z directions

Weight

Approx. 600 g

*1 The SI-F1003 can be used independently, The measured value display and setting change can be done with the display panel(SI-FD500) and setup support software(SI-H3).
*2 The SI-F1001 can be used independently. The measured value display and setting change can be done with the display panel (SI-FD500) and setup support software (SI-H1).
*3 • NPN open-collector output rating: 50 mA max. (40 V max.), Residual voltage: 0.5 V max.
• Non-voltage input rating: ON voltage: 1 V max., OFF current: 0.6 mA max.
• Part of the input/output circuit of the SI Series is internally common. Be careful that no potential difference is generated between the internally common terminals due to the potential difference between the cables/external
devices. For details, refer to "Precautions on wiring".
*4 When two or more expansion controllers are connected, the ambient temperature is 0 to +40 °C 32 to 104 °F.

keyence Stock Image
Keyence OP-87060 Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-87296 Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-87222 Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence New Stock Image
Keyence IB-30 Keyence
Sale price $797.58
Only 7 units left

Specifications

Model

IB-30

Light source

Wavelength

660 nm (Visible light semiconductor laser)

Laser Class

Class 1 Laser Product (IEC 60825-1, FDA (CDRH) Part 1040.10*1)

Installation distance

0 to 300 mm 11.81"

Measurement range

30 mm 1.18"

Sampling cycle

12,500 times/sec. (80 µs)

Minimum detection target

ø0.2 mm ø0.01"*2

Repeatability

10 µm 0.39 Mil*3

Temperature characteristics

±0.1 % of F.S./°C (±30 µm 1.18 Mil)*4

Operating indicators

Laser emission warning indicator: green LED

Environmental resistance

Ambient light

Incandescent lamp: 10,000 lux, Solar light: 10,000 lux

Ambient temperature

0 to +50 °C 32 to 122 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z axis

Material

Case

Galvanized die cast

Lens cover

Glass

Cable

PVC (2 m 6.6')

Weight

Approx. 510 g

*1 The classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice.
*2 Value when measuring the target (white diffuse object) at the middle of the transmitter and receiver position, and at the center of the measurement range.
*3 When distance between transmitter and receiver is set to 300 mm 11.81", and light is half-shielded at a position 150 mm 5.91" from receiver. Deflection width (±2σ) when sampled for 30 seconds with an average number of times set to 64 times.
*4 When distance between transmitter and receiver is set to 100 mm 3.94" and full light is received.

Keyence New Stock Image
Keyence IB-10 Keyence
Sale price $1,159.99
Only 9 units left

Specifications

Model

IB-10

Light source

Wavelength

660 nm (Visible light semiconductor laser)

Laser Class

Class 1 Laser Product (IEC 60825-1, FDA (CDRH) Part 1040.10*1)

Installation distance

0 to 300 mm 11.81"

Measurement range

10 mm 0.39"

Sampling cycle

12,500 times/sec. (80 µs)

Minimum detection target

ø0.1 mm ø0.004"*2

Repeatability

5 µm 0.20 Mil*3

Temperature characteristics

±0.1 % of F.S./°C (±10 µm 0.39 Mil)*4

Operating indicators

Laser emission warning indicator: green LED

Environmental resistance

Ambient light

Incandescent lamp: 10,000 lux, Solar light: 10,000 lux

Ambient temperature

0 to +50 °C 32 to 122 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z axis

Material

Case

Galvanized die cast

Lens cover

Glass

Cable

PVC (2 m 6.6')

Weight

Approx. 220 g

*1 The classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice.
*2 Value when measuring the target (white diffuse object) at the middle of the transmitter and receiver position, and at the center of the measurement range.
*3 When distance between transmitter and receiver is set to 300 mm 11.81", and light is half-shielded at a position 150 mm 5.91" from receiver. Deflection width (±2σ) when sampled for 30 seconds with an average number of times set to 64 times.
*4 When distance between transmitter and receiver is set to 100 mm 3.94" and full light is received.

Keyence Stock Image
Keyence IB-05 Keyence
Sale price $1,607.79
Only 5 units left

Specifications

Model

IB-05

Light source

Wavelength

660 nm (Visible light semiconductor laser)

Laser Class

Class 1 Laser Product (IEC 60825-1, FDA (CDRH) Part 1040.10*1)

Installation distance

0 to 300 mm 11.81"

Measurement range

5 mm 0.20"

Sampling cycle

12,500 times/sec. (80 µs)

Minimum detection target

ø0.05 mm ø0.002"*2

Repeatability

5 µm 0.20 Mil*3

Temperature characteristics

±0.1 % of F.S./°C (±5 µm 0.20 Mil)*4

Operating indicators

Laser emission warning indicator: green LED

Environmental resistance

Ambient light

Incandescent lamp: 5,000 lux, Solar light: 5,000 lux

Ambient temperature

0 to +50 °C 32 to 122 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z axis

Material

Case

Galvanized die cast

Lens cover

Glass

Cable

PVC (2 m 6.6')

Weight

Approx. 180 g

*1 The classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice.
*2 Value when measuring the target (white diffuse object) at the middle of the transmitter and receiver position, and at the center of the measurement range.
*3 When distance between transmitter and receiver is set to 300 mm 11.81", and light is half-shielded at a position 150 mm 5.91" from receiver. Deflection width (±2σ) when sampled for 30 seconds with an average number of times set to 64 times.
*4 When distance between transmitter and receiver is set to 100 mm 3.94" and full light is received.

keyence Stock Image
Keyence IB-01 Keyence
Sale price $3,266.00
Only 1 unit left

Specifications

Model

IB-01

Light source

Wavelength

660 nm (Visible light semiconductor laser)

Laser Class

Class 1 Laser Product (IEC 60825-1, FDA (CDRH) Part 1040.10*1)

Installation distance

0 to 2,000 mm 78.74"

Measurement range

ø1 mm ø0.04" (Installation distance 0 to 300 mm 11.81")
ø1 to 2.5 mm (Installation distance 300 to 2,000 mm 11.81" to 78.74")

Sampling cycle

12,500 times/sec. (80 µs)

Minimum detection target

ø8 µm ø0.31 Mil (Installation distance 0 to 300 mm 11.81")
ø8 to 50 µm ø0.31 to 1.97 Mil (Installation distance 300 to 2,000 mm 11.81" to 78.74")*2

Repeatability

5 µm 0.20 Mil (distance 0 to 300 mm 11.81")*3

Temperature characteristics

±0.2 % of F.S./°C*4

Operating indicators

Laser emission warning indicator: green LED

Environmental resistance

Ambient light

Incandescent lamp: 5,000 lux, Solar light: 10,000 lux

Ambient temperature

0 to +40 °C 32 to 104 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z axis

Material

Case

PBT

Lens cover

Glass

Cable

PVC (2 m 6.6')

Weight

Approx. 140 g

*1 The classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice.
*2 Value when measuring the target (white diffuse object) at the middle of the transmitter and receiver position, and at the center of the measurement range.
*3 When distance between transmitter and receiver is set to 300 mm 11.81", and light is half-shielded at a position 150 mm 5.91" from receiver. Deflection width (±2σ) when sampled for 30 seconds with an average number of times set to 64 times.
*4 When distance between transmitter and receiver is set to 100 mm 3.94" and full light is received.

keyence Stock Image
Keyence IB-1550 Keyence
Sale price$0.00
Sold Out

Specifications

Model

IB-1550

Type

Panel mount

Main unit/Expansion unit

Expansion unit

Head compatibility

Yes

Display

Display resolution

0.01 %, 0.1 %, 1 % (switchable)

Display range

–99.999 to 99.999, –99.99 to 99.99
–99.9 to 99.9, –99 to 99 (switchable)

Digital display method

Dual7-segmentdisplay
Upper level: 2-color (green/red) 5 digits
Lower level: 5 green digits

Operating indicators

Judgment indicator: 2-color (green/red) LED (HI, GO, LO)
Bank indicator: Green LED x 4
Laser emission warning indicator: Green LED
Others: Green LED x 8, red LED x 3

Analog output voltage

No

Analog current output

Control Input

Bank switch input, zero shift input

Non-voltage input *1

Control input

Zero shift input

Laser emission stop input

Timing input

Reset input

Adjust input

Control output

Judgment output (check output)

Open collector (NPN/PNP switchable, N.O./N.C. switchable) *2

Power supply

Power consumption

2550 mW or less (at 30 V, 85 mA max.) *3 *4 (including analog current output)

Power voltage

Supplied from main unit *3

Environmental resistance

Pollution degree

2

Ambient temperature

-10 to +50 °C (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, compound amplitude 1.5 mm, 2 hours each for X, Y, Z axes

Material

Main unit case/Front panel: polycarbonate, keytop: polyacetal, cable: PVC

Weight

Approx. 165 g (including accessories)

*1 The four external input wires are assigned with desired inputs.
Rated no-voltage input: ON voltage 2 V or less, OFF current 0.05 mA or less
Rated voltage input: Max. input rating 30 V or less, ON voltage 7.5 V or more, OFF current 0.05 mA or less
*2 Rated NPN open collector output: Max. 100 mA/ch (20 mA/ch when expansion units are connected), 30 V or less, residual voltage 1 V or less
Rated PNP open collector output: Max. 50 mA/ch (20 mA/ch when expansion units are connected), power voltage or less, residual voltage 2 V or less
*3 Use with the over current protection device which is rated 30 V or more and not more than 1 A.
*4 Does not include the power consumption of the load.
The power consumption with expansion units installed is the total of each amplifier unit’s power consumption.
Example: When using one main unit (IB-1000) with two expansion units (IB-1050) (2400 mW X 1) + (2400 mW X 2) = 7200 mW

keyence Stock Image
Keyence IB-1500 Keyence
Sale price $1,969.83
Only 7 units left

Specifications

Model

IB-1500

Type

Panel mount

Main unit/Expansion unit

Main unit

Head compatibility

Yes

Display

Display resolution

0.01 %, 0.1 %, 1 % (switchable)

Display range

–99.999 to 99.999, –99.99 to 99.99
–99.9 to 99.9, –99 to 99 (switchable)

Digital display method

Dual7-segmentdisplay
Upper level: 2-color (green/red) 5 digits
Lower level: 5 green digits

Operating indicators

Judgment indicator: 2-color (green/red) LED (HI, GO, LO)
Bank indicator: Green LED x 4
Laser emission warning indicator: Green LED
Others: Green LED x 8, red LED x 3

Analog output voltage

±5 V, 1 to 5 V, 0 to 5 V Output impedance 100 Ω *1

Analog current output

4 to 20 mA Maximum load resistance 350 Ω *1

Control Input

Bank switch input, zero shift input

Non-voltage input *2

Control input

Zero shift input

Laser emission stop input

Timing input

Reset input

Adjust input

Control output

Judgment output (check output)

Open collector (NPN/PNP switchable, N.O./N.C. switchable) *3

Power supply

Power consumption

2550 mW or less (at 30 V, 85 mA max.) *4 *5 (including analog current output)

Power voltage

10 to 30 VDC, including ripple (P-P) 10% Class 2 or LPS *4

Environmental resistance

Pollution degree

2

Ambient temperature

-10 to +50 °C (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, compound amplitude 1.5 mm, 2 hours each for X, Y, Z axes

Material

Main unit case/Front panel: polycarbonate, keytop: polyacetal, cable: PVC

Weight

Approx. 170 g (including accessories)

*1 ±5 V, 1 to 5 V, 0 to 5 V, or 4 - 20 mA should be selected.
*2 The four external input wires are assigned with desired inputs.
Rated no-voltage input: ON voltage 2 V or less, OFF current 0.05 mA or less
Rated voltage input: Max. input rating 30 V or less, ON voltage 7.5 V or more, OFF current 0.05 mA or less
*3 Rated NPN open collector output: Max. 100 mA/ch (20 mA/ch when expansion units are connected), 30 V or less, residual voltage 1 V or less
Rated PNP open collector output: Max. 50 mA/ch (20 mA/ch when expansion units are connected), power voltage or less, residual voltage 2 V or less
*4 Use with the over current protection device which is rated 30 V or more and not more than 1 A.
*5 Does not include the power consumption of the load.
The power consumption with expansion units installed is the total of each amplifier unit’s power consumption.
Example: When using one main unit (IB-1000) with two expansion units (IB-1050) (2400 mW X 1) + (2400 mW X 2) = 7200 mW

keyence Stock Image
Keyence IB-1050 Keyence
Sale price $640.67
Only 5 units left

Specifications

Model

IB-1050

Type

DIN rail mount

Main unit/Expansion unit

Expansion unit

Head compatibility

Yes

Display

Display resolution

0.01 %, 0.1 %, 1 % (switchable)

Display range

–99.999 to 99.999, –99.99 to 99.99
–99.9 to 99.9, –99 to 99 (switchable)

Digital display method

Dual7-segmentdisplay
Upper level: 5 red digits
Lower level: 5 green digits

Operating indicators

Judgment indicator: 2-color (green/red) LED (HI, GO, LO)
Bank indicator: Green LED x 4
Laser emission warning indicator: Green LED
Others: Green LED x 8, red LED x 3

Analog output voltage

No

Analog current output

Control Input

Bank switch input, zero shift input

Non-voltage input *1

Control input

Zero shift input

Laser emission stop input

Timing input

Reset input

Adjust input

Control output

Judgment output (check output)

Open collector (NPN/PNP switchable, N.O./N.C. switchable) *2

Power supply

Power consumption

2400 mW or less (at 30 V, 80 mA max.) *3 *4 (including analog current output)

Power voltage

Supplied from main unit *3

Environmental resistance

Pollution degree

2

Ambient temperature

-10 to +50 °C (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, compound amplitude 1.5 mm, 2 hours each for X, Y, Z axes

Material

Main unit case/Front panel: polycarbonate, keytop: polyacetal, cable: PVC

Weight

Approx. 140 g (including accessories)

*1 The four external input wires are assigned with desired inputs.
Rated no-voltage input: ON voltage 2 V or less, OFF current 0.05 mA or less
Rated voltage input: Max. input rating 30 V or less, ON voltage 7.5 V or more, OFF current 0.05 mA or less
*2 Rated NPN open collector output: Max. 100 mA/ch (20 mA/ch when expansion units are connected), 30 V or less, residual voltage 1 V or less
Rated PNP open collector output: Max. 50 mA/ch (20 mA/ch when expansion units are connected), power voltage or less, residual voltage 2 V or less
*3 Use with the over current protection device which is rated 30 V or more and not more than 1 A.
*4 Does not include the power consumption of the load.
The power consumption with expansion units installed is the total of each amplifier unit’s power consumption.
Example: When using one main unit (IB-1000) with two expansion units (IB-1050) (2400 mW X 1) + (2400 mW X 2) = 7200 mW

Keyence New Stock Image
Keyence IB-1000 Keyence
Sale price $606.14
Only 9 units left

Specifications

Model

IB-1000

Type

DIN rail mount

Main unit/Expansion unit

Main unit

Head compatibility

Yes

Display

Display resolution

0.01 %, 0.1 %, 1 % (switchable)

Display range

–99.999 to 99.999, –99.99 to 99.99
–99.9 to 99.9, –99 to 99 (switchable)

Digital display method

Dual7-segmentdisplay
Upper level: 5 red digits
Lower level: 5 green digits

Operating indicators

Judgment indicator: 2-color (green/red) LED (HI, GO, LO)
Bank indicator: Green LED x 4
Laser emission warning indicator: Green LED
Others: Green LED x 8, red LED x 3

Analog output voltage

±5 V, 1 to 5 V, 0 to 5 V Output impedance 100 Ω *1

Analog current output

4 to 20 mA Maximum load resistance 350 Ω *1

Control Input

Bank switch input, zero shift input

Non-voltage input *2

Control input

Zero shift input

Laser emission stop input

Timing input

Reset input

Adjust input

Control output

Judgment output (check output)

Open collector (NPN/PNP switchable, N.O./N.C. switchable) *3

Power supply

Power consumption

2400 mW or less (at 30 V, 80 mA max.) *4 *5 (including analog current output)

Power voltage

10 to 30 VDC, including ripple (P-P) 10% Class 2 or LPS *4

Environmental resistance

Pollution degree

2

Ambient temperature

-10 to +50 °C (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, compound amplitude 1.5 mm, 2 hours each for X, Y, Z axes

Material

Main unit case/Front panel: polycarbonate, keytop: polyacetal, cable: PVC

Weight

Approx. 150 g (including accessories)

*1 ±5 V, 1 to 5 V, 0 to 5 V, or 4 - 20 mA should be selected.
*2 The four external input wires are assigned with desired inputs.
Rated no-voltage input: ON voltage 2 V or less, OFF current 0.05 mA or less
Rated voltage input: Max. input rating 30 V or less, ON voltage 7.5 V or more, OFF current 0.05 mA or less
*3 Rated NPN open collector output: Max. 100 mA/ch (20 mA/ch when expansion units are connected), 30 V or less, residual voltage 1 V or less
Rated PNP open collector output: Max. 50 mA/ch (20 mA/ch when expansion units are connected), power voltage or less, residual voltage 2 V or less
*4 Use with the over current protection device which is rated 30 V or more and not more than 1 A.
*5 Does not include the power consumption of the load.
The power consumption with expansion units installed is the total of each amplifier unit’s power consumption.
Example: When using one main unit (IB-1000) with two expansion units (IB-1050) (2400 mW X 1) + (2400 mW X 2) = 7200 mW