Measurement Sensors
719 products
Showing 529 - 552 of 719 products

Specifications
Model |
EX-416V*1 |
|||
Type |
Sensor head |
|||
Amplifier unit |
NPN: EX-V05 |
|||
Shape |
ø14.5 x 20 mm |
|||
Measuring range |
0 to 5 mm 0 to 0.20" |
|||
Display range |
-19,999 to +19,999 |
|||
Linearity |
±0.3% of F.S. |
|||
Resolution (No. of averaging |
1 μm |
|||
Sampling rate |
40,000 samplings max./sec. *2 |
|||
Display speed |
20 times/sec. |
|||
Display power |
7-segment 2-color LED |
|||
Over-range alarm |
±FFFF is displayed. |
|||
Control input |
NPN open-collector or non-voltage contact (Timing input, Reset input, Auto-zero input, Comparator output disable input, Synchronous input, External setting input)/PNP: Applied voltage; 10 to 30 V |
|||
Control output |
Setting method |
Upper/lower 2-level setting x 4 patterns (selectable) |
||
Signal |
NPN open-collector (HIGH, GO and LOW): 100 mA max. (40 V max.) |
|||
Response time |
0.075 ms (at maximum speed) |
|||
OFF-delay time |
60 ms |
|||
Strobe output |
NPN: 100 mA max. (40 V max.)/PNP: 100 mA max. (30 V max.), Residual voltage: 1 V max. (N.O.) |
|||
Alarm output |
NPN: 100 mA max. (40 V max.)/PNP: 100 mA max. (30 V max.), Residual voltage: 1 V max. (N.C.) |
|||
Analog output voltage |
Output voltage |
±5V |
||
Impedance |
100 Ω |
|||
Response time |
0.075 ms (at maximum speed) |
|||
Temperature characteristics |
0.07% of F.S./°C *3 |
|||
Major functions |
FLL, digital filter, auto zero, offset, calculation, measurement mode (15 types), judgment value memory (4 sets), decimal point shift, display digit changing, display of various errors, etc. |
|||
Rating |
Power voltage |
24 VDC ±10%, Ripple (P-P): 10% max. |
||
Current consumption |
240 mA max. |
|||
Environmental resistance |
Ambient temperature |
-10 to +60 °C 14 to 140 °F, No freezing |
||
Relative humidity |
35 to 85%, No condensation |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Weight |
Approx. 75 g (including 3 m 9.8' cable) |
|||
*1 The above data was obtained using an iron target (S45C, SS400, t=1 mm 0.04"). When measuring aluminum, copper, or stainless steel targets, refer to the linear characteristics for these materials. | ||||
Scroll

Specifications
Model |
EX-305V*1 |
|||
Type |
Sensor head |
|||
Amplifier unit |
NPN: EX-V01 |
|||
Shape |
ø5.4 x 18 mm |
|||
Measuring range |
0 to 1 mm 0 to 0.04" |
|||
Display range |
-19,999 to +19,999 |
|||
Linearity |
±0.3% of F.S. |
|||
Resolution (No. of averaging |
0.4 μm |
|||
Sampling rate |
40,000 samplings max./sec. *2 |
|||
Display speed |
20 times/sec. |
|||
Display power |
7-segment 2-color LED |
|||
Over-range alarm |
±FFFF is displayed. |
|||
Control input |
NPN open-collector or non-voltage contact (Timing input, Reset input, Auto-zero input, Comparator output disable input, Synchronous input, External setting input)/PNP: Applied voltage; 10 to 30 V |
|||
Control output |
Setting method |
Upper/lower 2-level setting x 4 patterns (selectable) |
||
Signal |
NPN open-collector (HIGH, GO and LOW): 100 mA max. (40 V max.) |
|||
Response time |
0.075 ms (at maximum speed) |
|||
OFF-delay time |
60 ms |
|||
Strobe output |
NPN: 100 mA max. (40 V max.)/PNP: 100 mA max. (30 V max.), Residual voltage: 1 V max. (N.O.) |
|||
Alarm output |
NPN: 100 mA max. (40 V max.)/PNP: 100 mA max. (30 V max.), Residual voltage: 1 V max. (N.C.) |
|||
Analog output voltage |
Output voltage |
±5V |
||
Impedance |
100 Ω |
|||
Response time |
0.075 ms (at maximum speed) |
|||
Temperature characteristics |
0.07% of F.S./°C *3 |
|||
Major functions |
FLL, digital filter, auto zero, offset, calculation, measurement mode (15 types), judgment value memory (4 sets), decimal point shift, display digit changing, display of various errors, etc. |
|||
Rating |
Power voltage |
24 VDC ±10%, Ripple (P-P): 10% max. |
||
Current consumption |
240 mA max. |
|||
Environmental resistance |
Ambient temperature |
-10 to +60 °C 14 to 140 °F, No freezing |
||
Relative humidity |
35 to 85%, No condensation |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Weight |
Approx. 45 g (including 3 m 9.8' cable) |
|||
*1 The above data was obtained using an iron target (S45C, SS400, t=1 mm 0.04"). When measuring aluminum, copper, or stainless steel targets, refer to the linear characteristics for these materials. | ||||
Scroll

Specifications
Model |
EX-V64P*1 |
|||
Type |
Amplifier Unit PNP |
|||
Shape |
14 x 30 x 4.8 mm 0.55" x 1.18" x 0.19" Thin profile |
|||
Measuring range |
0 to 4 mm 0.157" |
|||
Display range |
-19,999 to +19,999 |
|||
Linearity |
±0.3% of F.S. |
|||
Resolution (No. of averaging |
1 µm |
|||
Sampling rate |
40,000 samplings max./sec. *2 |
|||
Display speed |
20 times/sec. |
|||
Display power |
7-segment 2-color LED |
|||
Over-range alarm |
±FFFF is displayed. |
|||
Control input |
PNP: Applied voltage; 10 to 30 V |
|||
Control output |
Setting method |
Upper/lower 2-level setting x 4 patterns (selectable) |
||
Signal |
PNP open-collector (HIGH, GO and LOW): 100 mA max. (30 V max.) |
|||
Response time |
0.075 ms (at maximum speed) |
|||
OFF-delay time |
60 ms |
|||
Strobe output |
PNP: 100 mA max. (30 V max.), Residual voltage: 1 V max. (N.O.) |
|||
Alarm output |
PNP: 100 mA max. (30 V max.), Residual voltage: 1 V max. (N.C.) |
|||
Analog output voltage |
Output voltage |
±5V |
||
Impedance |
100 Ω |
|||
Response time |
0.075 ms (at maximum speed) |
|||
Temperature characteristics |
0.07% of F.S./°C *3 |
|||
Major functions |
FLL, digital filter, auto zero, offset, calculation, measurement mode (15 types), judgment value memory (4 sets), decimal point shift, display digit changing, display of various errors, etc. |
|||
Rating |
Power voltage |
24 VDC ±10%, Ripple (P-P): 10% max. |
||
Current consumption |
240 mA max. |
|||
Environmental resistance |
Ambient temperature |
0 to 50°C 32 to 122 °F |
||
Relative humidity |
35 to 85%, No condensation |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Weight |
Approx. 235 g |
|||
*1 The above data was obtained using an iron target (S45C, SS400, t=1 mm 0.04"). When measuring aluminum, copper, or stainless steel targets, refer to the linear characteristics for these materials. | ||||
Scroll

Specifications
Model |
EX-V64E |
|||
Type |
Controller |
|||
Shape |
14 x 30 x 4.8 mm 0.55" x 1.18" x 0.19" Thin profile |
|||
Measuring range |
0 to 4 mm 0.16" |
|||
Display range |
-19,999 to +19,999 |
|||
Linearity |
±0.3% of F.S. |
|||
Resolution (No. of averaging |
1 µm |
|||
Sampling rate |
40,000 samplings max./sec. *1 |
|||
Display speed |
20 times/sec. (2-color, 7-segment LED) |
|||
Display power |
7-segment 2-color LED |
|||
Over-range alarm |
±FFFF is displayed. |
|||
Control input |
Timing input |
NPN open-collector or non-voltage contact signal |
||
Reset input | ||||
Auto-zero input | ||||
Judgment output: Inhibit input | ||||
Synchronization/external settings input | ||||
Control output |
Setting method |
Upper/lower 2-level setting x 4 patterns (selectable) |
||
Signal |
NPN open-collector (HIGH, GO and LOW): 100 mA max. (40 V max.) |
|||
Response time |
0.075 ms (at maximum speed) |
|||
OFF-delay time |
60 ms (ON/OFF selectable) |
|||
Strobe output |
NPN: 100 mA max. (40 V max.), Residual voltage: 1 V max. (N.O.) |
|||
Alarm output |
NPN: 100 mA max. (40 V max.), Residual voltage: 1 V max. (N.C.) |
|||
Analog output voltage |
Output voltage |
±5V |
||
Impedance |
100 Ω |
|||
Response time |
0.075 ms (at maximum speed) |
|||
Temperature characteristics |
0.07% of F.S./°C *2 |
|||
Major functions |
FLL, digital filter, auto zero, offset, calculation, measurement mode (15 types), judgment value memory (4 sets), decimal point shift, display digit changing, display of various errors, etc. |
|||
Rating |
Power voltage |
24 VDC ±10 %, Ripple (P-P) 10 % or less |
||
Current consumption |
240 mA or less |
|||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Weight |
Approx. 235 g |
|||
*1 When the digital filter function is used, the sampling rate is 20,000 sampling/sec. | ||||
Scroll

Specifications
Model |
EX-V10P*1 |
|||
Type |
Amplifier Unit PNP |
|||
Shape |
ø22 x 35 mm ø0.87" x 1.38" Cylindrical, threaded |
|||
Measuring range |
0 to 10 mm 0" to 0.394" |
|||
Display range |
-19,999 to +19,999 |
|||
Linearity |
±0.3% of F.S. |
|||
Resolution (No. of averaging |
2 µm |
|||
Sampling rate |
40,000 samplings max./sec. *2 |
|||
Display speed |
20 times/sec. |
|||
Display power |
7-segment 2-color LED |
|||
Over-range alarm |
±FFFF is displayed. |
|||
Control input |
PNP: Applied voltage; 10 to 30 V |
|||
Control output |
Setting method |
Upper/lower 2-level setting x 4 patterns (selectable) |
||
Signal |
PNP open-collector (HIGH, GO and LOW): 100 mA max. (30 V max.) |
|||
Response time |
0.075 ms (at maximum speed) |
|||
OFF-delay time |
60 ms |
|||
Strobe output |
PNP: 100 mA max. (30 V max.), Residual voltage: 1 V max. (N.O.) |
|||
Alarm output |
PNP: 100 mA max. (30 V max.), Residual voltage: 1 V max. (N.C.) |
|||
Analog output voltage |
Output voltage |
±5V |
||
Impedance |
100 Ω |
|||
Response time |
0.075 ms (at maximum speed) |
|||
Temperature characteristics |
0.07% of F.S./°C *3 |
|||
Major functions |
FLL, digital filter, auto zero, offset, calculation, measurement mode (15 types), judgment value memory (4 sets), decimal point shift, display digit changing, display of various errors, etc. |
|||
Rating |
Power voltage |
24 VDC ±10%, Ripple (P-P): 10% max. |
||
Current consumption |
240 mA max. |
|||
Environmental resistance |
Ambient temperature |
0 to 50°C 32 to 122 °F |
||
Relative humidity |
35 to 85%, No condensation |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Weight |
Approx. 235 g |
|||
*1 The above data was obtained using an iron target (S45C, SS400, t=1 mm 0.04"). When measuring aluminum, copper, or stainless steel targets, refer to the linear characteristics for these materials. | ||||
Scroll

Specifications
Model |
EX-V10E |
|||
Type |
Controller |
|||
Shape |
ø22 x 35 mm ø0.87" x 1.38" Cylindrical, threaded |
|||
Measuring range |
0 to 10 mm0" to 0.394" |
|||
Display range |
-19,999 to +19,999 |
|||
Linearity |
±0.3% of F.S. |
|||
Resolution (No. of averaging |
2 µm |
|||
Sampling rate |
40,000 samplings max./sec. *1 |
|||
Display speed |
20 times/sec. (2-color, 7-segment LED) |
|||
Display power |
7-segment 2-color LED |
|||
Over-range alarm |
±FFFF is displayed. |
|||
Control input |
Timing input |
NPN open-collector or non-voltage contact signal |
||
Reset input | ||||
Auto-zero input | ||||
Judgment output: Inhibit input | ||||
Synchronization/external settings input | ||||
Control output |
Setting method |
Upper/lower 2-level setting x 4 patterns (selectable) |
||
Signal |
NPN open-collector (HIGH, GO and LOW): 100 mA max. (40 V max.) |
|||
Response time |
0.075 ms (at maximum speed) |
|||
OFF-delay time |
60 ms (ON/OFF selectable) |
|||
Strobe output |
NPN: 100 mA max. (40 V max.), Residual voltage: 1 V max. (N.O.) |
|||
Alarm output |
NPN: 100 mA max. (40 V max.), Residual voltage: 1 V max. (N.C.) |
|||
Analog output voltage |
Output voltage |
±5V |
||
Impedance |
100 Ω |
|||
Response time |
0.075 ms (at maximum speed) |
|||
Temperature characteristics |
0.07% of F.S./°C *2 |
|||
Major functions |
FLL, digital filter, auto zero, offset, calculation, measurement mode (15 types), judgment value memory (4 sets), decimal point shift, display digit changing, display of various errors, etc. |
|||
Rating |
Power voltage |
24 VDC ±10 %, Ripple (P-P) 10 % or less |
||
Current consumption |
240 mA or less |
|||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Weight |
Approx. 235 g |
|||
*1 When the digital filter function is used, the sampling rate is 20,000 sampling/sec. | ||||
Scroll

Specifications
Model |
EX-V05P*1 |
|||
Type |
Amplifier Unit PNP |
|||
Shape |
ø14.5 x 20 mm ø0.57" x 0.79" Cylindrical, threaded |
|||
Measuring range |
0 to 5 mm 0.20" |
|||
Display range |
-19,999 to +19,999 |
|||
Linearity |
±0.3% of F.S. |
|||
Resolution (No. of averaging |
1 µm |
|||
Sampling rate |
40,000 samplings max./sec. *2 |
|||
Display speed |
20 times/sec. |
|||
Display power |
7-segment 2-color LED |
|||
Over-range alarm |
±FFFF is displayed. |
|||
Control input |
PNP: Applied voltage; 10 to 30 V |
|||
Control output |
Setting method |
Upper/lower 2-level setting x 4 patterns (selectable) |
||
Signal |
PNP open-collector (HIGH, GO and LOW): 100 mA max. (30 V max.) |
|||
Response time |
0.075 ms (at maximum speed) |
|||
OFF-delay time |
60 ms |
|||
Strobe output |
PNP: 100 mA max. (30 V max.), Residual voltage: 1 V max. (N.O.) |
|||
Alarm output |
PNP: 100 mA max. (30 V max.), Residual voltage: 1 V max. (N.C.) |
|||
Analog output voltage |
Output voltage |
±5V |
||
Impedance |
100 Ω |
|||
Response time |
0.075 ms (at maximum speed) |
|||
Temperature characteristics |
0.07% of F.S./°C *3 |
|||
Major functions |
FLL, digital filter, auto zero, offset, calculation, measurement mode (15 types), judgment value memory (4 sets), decimal point shift, display digit changing, display of various errors, etc. |
|||
Rating |
Power voltage |
24 VDC ±10%, Ripple (P-P): 10% max. |
||
Current consumption |
240 mA max. |
|||
Environmental resistance |
Ambient temperature |
0 to 50°C 32 to 122 °F |
||
Relative humidity |
35 to 85%, No condensation |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Weight |
Approx. 235 g |
|||
*1 The above data was obtained using an iron target (S45C, SS400, t=1 mm 0.04"). When measuring aluminum, copper, or stainless steel targets, refer to the linear characteristics for these materials. | ||||
Scroll

Specifications
Model |
EX-V05E |
|||
Type |
Controller |
|||
Shape |
ø14.5 x 20 mm ø0.57" x 0.79" Cylindrical, threaded |
|||
Measuring range |
0 to 5 mm 0.20" |
|||
Display range |
-19,999 to +19,999 |
|||
Linearity |
±0.3% of F.S. |
|||
Resolution (No. of averaging |
1 µm |
|||
Sampling rate |
40,000 samplings max./sec. *1 |
|||
Display speed |
20 times/sec. (2-color, 7-segment LED) |
|||
Display power |
7-segment 2-color LED |
|||
Over-range alarm |
±FFFF is displayed. |
|||
Control input |
Timing input |
NPN open-collector or non-voltage contact signal |
||
Reset input | ||||
Auto-zero input | ||||
Judgment output: Inhibit input | ||||
Synchronization/external settings input | ||||
Control output |
Setting method |
Upper/lower 2-level setting x 4 patterns (selectable) |
||
Signal |
NPN open-collector (HIGH, GO and LOW): 100 mA max. (40 V max.) |
|||
Response time |
0.075 ms (at maximum speed) |
|||
OFF-delay time |
60 ms (ON/OFF selectable) |
|||
Strobe output |
NPN: 100 mA max. (40 V max.), Residual voltage: 1 V max. (N.O.) |
|||
Alarm output |
NPN: 100 mA max. (40 V max.), Residual voltage: 1 V max. (N.C.) |
|||
Analog output voltage |
Output voltage |
±5V |
||
Impedance |
100 Ω |
|||
Response time |
0.075 ms (at maximum speed) |
|||
Temperature characteristics |
0.07% of F.S./°C *2 |
|||
Major functions |
FLL, digital filter, auto zero, offset, calculation, measurement mode (15 types), judgment value memory (4 sets), decimal point shift, display digit changing, display of various errors, etc. |
|||
Rating |
Power voltage |
24 VDC ±10 %, Ripple (P-P) 10 % or less |
||
Current consumption |
240 mA or less |
|||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Weight |
Approx. 235 g |
|||
*1 When the digital filter function is used, the sampling rate is 20,000 sampling/sec. | ||||
Scroll

Specifications
Model |
EX-V02P*1 |
|||
Type |
Amplifier Unit PNP |
|||
Shape |
M10 x 18 mm 0.71" Threaded |
|||
Measuring range |
0 to 2 mm 0.08" |
|||
Display range |
-19,999 to +19,999 |
|||
Linearity |
±0.3% of F.S. |
|||
Resolution (No. of averaging |
0.4 μm |
|||
Sampling rate |
40,000 samplings max./sec. *2 |
|||
Display speed |
20 times/sec. |
|||
Display power |
7-segment 2-color LED |
|||
Over-range alarm |
±FFFF is displayed. |
|||
Control input |
PNP: Applied voltage; 10 to 30 V |
|||
Control output |
Setting method |
Upper/lower 2-level setting x 4 patterns (selectable) |
||
Signal |
PNP open-collector (HIGH, GO and LOW): 100 mA max. (30 V max.) |
|||
Response time |
0.075 ms (at maximum speed) |
|||
OFF-delay time |
60 ms |
|||
Strobe output |
PNP: 100 mA max. (30 V max.), Residual voltage: 1 V max. (N.O.) |
|||
Alarm output |
PNP: 100 mA max. (30 V max.), Residual voltage: 1 V max. (N.C.) |
|||
Analog output voltage |
Output voltage |
±5V |
||
Impedance |
100 Ω |
|||
Response time |
0.075 ms (at maximum speed) |
|||
Temperature characteristics |
0.07% of F.S./°C *3 |
|||
Major functions |
FLL, digital filter, auto zero, offset, calculation, measurement mode (15 types), judgment value memory (4 sets), decimal point shift, display digit changing, display of various errors, etc. |
|||
Rating |
Power voltage |
24 VDC ±10%, Ripple (P-P): 10% max. |
||
Current consumption |
240 mA max. |
|||
Environmental resistance |
Ambient temperature |
0 to 50°C 32 to 122 °F |
||
Relative humidity |
35 to 85%, No condensation |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Weight |
Approx. 235 g |
|||
*1 The above data was obtained using an iron target (S45C, SS400, t=1 mm 0.04"). When measuring aluminum, copper, or stainless steel targets, refer to the linear characteristics for these materials. | ||||
Scroll

Specifications
Model |
EX-V02E |
|||
Type |
Controller |
|||
Shape |
M10 x 18 mm 0.71" Threaded |
|||
Measuring range |
0 to 2 mm 0.08" |
|||
Display range |
-19,999 to +19,999 |
|||
Linearity |
±0.3% of F.S. |
|||
Resolution (No. of averaging |
0.4 µm 0.016 Mil |
|||
Sampling rate |
40,000 samplings max./sec. *1 |
|||
Display speed |
20 times/sec. (2-color, 7-segment LED) |
|||
Display power |
7-segment 2-color LED |
|||
Over-range alarm |
±FFFF is displayed. |
|||
Control input |
Timing input |
NPN open-collector or non-voltage contact signal |
||
Reset input | ||||
Auto-zero input | ||||
Judgment output: Inhibit input | ||||
Synchronization/external settings input | ||||
Control output |
Setting method |
Upper/lower 2-level setting x 4 patterns (selectable) |
||
Signal |
NPN open-collector (HIGH, GO and LOW): 100 mA max. (40 V max.) |
|||
Response time |
0.075 ms (at maximum speed) |
|||
OFF-delay time |
60 ms (ON/OFF selectable) |
|||
Strobe output |
NPN: 100 mA max. (40 V max.), Residual voltage: 1 V max. (N.O.) |
|||
Alarm output |
NPN: 100 mA max. (40 V max.), Residual voltage: 1 V max. (N.C.) |
|||
Analog output voltage |
Output voltage |
±5V |
||
Impedance |
100 Ω |
|||
Response time |
0.075 ms (at maximum speed) |
|||
Temperature characteristics |
0.07% of F.S./°C *2 |
|||
Major functions |
FLL, digital filter, auto zero, offset, calculation, measurement mode (15 types), judgment value memory (4 sets), decimal point shift, display digit changing, display of various errors, etc. |
|||
Rating |
Power voltage |
24 VDC ±10 %, Ripple (P-P) 10 % or less |
||
Current consumption |
240 mA or less |
|||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Weight |
Approx. 235 g |
|||
*1 When the digital filter function is used, the sampling rate is 20,000 sampling/sec. | ||||
Scroll

Specifications
Model |
EX-V01P*1 |
|||
Type |
Amplifier Unit PNP |
|||
Shape |
ø5.4 x 18 mm ø0.21" x 0.71" Cylindrical |
|||
Measuring range |
0 to 1 mm 0.04" |
|||
Display range |
-19,999 to +19,999 |
|||
Linearity |
±0.3% of F.S. |
|||
Resolution (No. of averaging |
0.4 μm |
|||
Sampling rate |
40,000 samplings max./sec. *2 |
|||
Display speed |
20 times/sec. |
|||
Display power |
7-segment 2-color LED |
|||
Over-range alarm |
±FFFF is displayed. |
|||
Control input |
PNP: Applied voltage; 10 to 30 V |
|||
Control output |
Setting method |
Upper/lower 2-level setting x 4 patterns (selectable) |
||
Signal |
PNP open-collector (HIGH, GO and LOW): 100 mA max. (30 V max.) |
|||
Response time |
0.075 ms (at maximum speed) |
|||
OFF-delay time |
60 ms |
|||
Strobe output |
PNP: 100 mA max. (30 V max.), Residual voltage: 1 V max. (N.O.) |
|||
Alarm output |
PNP: 100 mA max. (30 V max.), Residual voltage: 1 V max. (N.C.) |
|||
Analog output voltage |
Output voltage |
±5V |
||
Impedance |
100 Ω |
|||
Response time |
0.075 ms (at maximum speed) |
|||
Temperature characteristics |
0.07% of F.S./°C *3 |
|||
Major functions |
FLL, digital filter, auto zero, offset, calculation, measurement mode (15 types), judgment value memory (4 sets), decimal point shift, display digit changing, display of various errors, etc. |
|||
Rating |
Power voltage |
24 VDC ±10%, Ripple (P-P): 10% max. |
||
Current consumption |
240 mA max. |
|||
Environmental resistance |
Ambient temperature |
0 to 50°C 32 to 122 °F |
||
Relative humidity |
35 to 85%, No condensation |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Weight |
Approx. 235 g |
|||
*1 The above data was obtained using an iron target (S45C, SS400, t=1 mm 0.04"). When measuring aluminum, copper, or stainless steel targets, refer to the linear characteristics for these materials. | ||||
Scroll

Specifications
Model |
EX-V01E |
|||
Type |
Controller |
|||
Shape |
ø5.4 x 18 mm ø0.21" x 0.71" Cylindrical |
|||
Measuring range |
0 to 1 mm 0.04" |
|||
Display range |
-19,999 to +19,999 |
|||
Linearity |
±0.3% of F.S. |
|||
Resolution (No. of averaging |
0.4 µm 0.016 Mil |
|||
Sampling rate |
40,000 samplings max./sec. *1 |
|||
Display speed |
20 times/sec. (2-color, 7-segment LED) |
|||
Display power |
7-segment 2-color LED |
|||
Over-range alarm |
±FFFF is displayed. |
|||
Control input |
Timing input |
NPN open-collector or non-voltage contact signal |
||
Reset input | ||||
Auto-zero input | ||||
Judgment output: Inhibit input | ||||
Synchronization/external settings input | ||||
Control output |
Setting method |
Upper/lower 2-level setting x 4 patterns (selectable) |
||
Signal |
NPN open-collector (HIGH, GO and LOW): 100 mA max. (40 V max.) |
|||
Response time |
0.075 ms (at maximum speed) |
|||
OFF-delay time |
60 ms (ON/OFF selectable) |
|||
Strobe output |
NPN: 100 mA max. (40 V max.), Residual voltage: 1 V max. (N.O.) |
|||
Alarm output |
NPN: 100 mA max. (40 V max.), Residual voltage: 1 V max. (N.C.) |
|||
Analog output voltage |
Output voltage |
±5V |
||
Impedance |
100 Ω |
|||
Response time |
0.075 ms (at maximum speed) |
|||
Temperature characteristics |
0.07% of F.S./°C *2 |
|||
Major functions |
FLL, digital filter, auto zero, offset, calculation, measurement mode (15 types), judgment value memory (4 sets), decimal point shift, display digit changing, display of various errors, etc. |
|||
Rating |
Power voltage |
24 VDC ±10 %, Ripple (P-P) 10 % or less |
||
Current consumption |
240 mA or less |
|||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Weight |
Approx. 235 g |
|||
*1 When the digital filter function is used, the sampling rate is 20,000 sampling/sec. | ||||
Scroll

Specifications
Model |
SI-F80RU |
|||
Type |
Wafer Thickness Measurement Type Spectrum Unit |
|||
Measurement range |
10 to 310 µm 0.000394" to 0.0122" (when n=3.5)*1 |
|||
Possible detection distance |
80 to 81.1 mm 3.15" to 3.19" |
|||
Light source |
Infrared SLD Output 0.6 mW, Class 1 Laser Product (IEC60825-1, FDA (CDRH) Part 1040.10*2) |
|||
Spot diameter |
ø25 µm*3 |
|||
Linearity |
±0.1 µm ±0.000004" (when n=3.5)*4 |
|||
Resolution |
0.001 µm *5 |
|||
Sampling cycle |
200 µs |
|||
LED display |
Target near center of measurement range : green lights. Target within measurement range : orange lights. |
|||
Temperature fluctuation |
0.01% of F.S./°C |
|||
Environmental resistance |
Enclosure rating |
- |
||
Ambient light |
Incandescent lamp or Fluorescent lamp: 10,000 lux max. |
|||
Ambient temperature |
0 to +35 °C 32 to 95 °F |
|||
Relative humidity |
35 to 80 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 0.5 mm 0.02", 2 hours in each of the X, Y, and Z directions |
|||
Material |
Polycarbonate |
|||
Weight |
Approx. 1.2 kg |
|||
*1 Indicates the thickness measurement range when the refractive index is 3.5. (The thickness measurement range is 35 to 1100 µm0.001378" to 0.0433" when the refractive index is 1.) | ||||
Scroll

Specifications
Model |
SI-F80R*1 |
|||
Type |
Wafer thickness measurement type Sensor head |
|||
Measurement range |
10 to 310 µm 0.000394" to 0.0122" (when n=3.5)*2 |
|||
Possible detection distance |
80 to 81.1 mm 3.15" to 3.19" |
|||
Light source |
Infrared SLD Output 0.6 mW, Class 1 Laser Product (IEC60825-1, FDA (CDRH) Part 1040.10*3) |
|||
Spot diameter |
ø25 µm ø0.000984"*4 |
|||
Linearity |
±0.1 µm ±0.000004" (when n=3.5)*5 |
|||
Resolution |
0.001 µm *6 |
|||
Sampling cycle |
200 µs |
|||
LED display |
Target near center of measurement range : green lights. Target within measurement range : orange lights. |
|||
Temperature fluctuation |
― |
|||
Environmental resistance |
Enclosure rating |
IP64 |
||
Ambient light |
Incandescent lamp or Fluorescent lamp: 10,000 lux max. |
|||
Ambient temperature |
0 to +50 °C 32 to 122 °F |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Material |
SUS |
|||
Weight |
Approx. 70 g (including cable) |
|||
*1 The sensor head and spectrum unit are calibrated as a pair. They are not interchangeable. | ||||
Scroll




Specifications
Model |
SI-H13*1 |
|||
Type |
Configuration Software for the SI Series |
|||
Operating System |
Windows 11 Pro |
|||
CPU |
Pentium III 1 GHz or higher (1.7 GHz or higher recommended) |
|||
Memory capacity |
256 MB or more (1 GB or more recommended) |
|||
Available hard disk space |
1 GB or more |
|||
Display |
1024 x 768 pixels, 24-bit full color or better |
|||
PC interface |
The PC must be equipped with one of these interfaces: |
|||
*1 Use under an environment that exceeds the recommended environment of the your OS. | ||||
Scroll

Specifications
Model |
SI-H1*1 |
|||
Type |
Configuration Software for the SI Series |
|||
Operating System |
Windows 11 Pro |
|||
CPU |
Pentium III 1 GHz or higher (1.7 GHz or higher recommended) |
|||
Memory capacity |
256 MB or more (1 GB or more recommended) |
|||
Available hard disk space |
1 GB or more |
|||
Display |
1024 x 768 pixels, 24-bit full color or better |
|||
PC interface |
The PC must be equipped with one of these interfaces: |
|||
*1 Use under an environment that exceeds the recommended environment of the your OS. | ||||
Scroll

Specifications
Model |
SI-F80U3 |
|||
Measurement range |
0.05 to 1.1 mm 0.002" to 0.04" *1 |
|||
Light source |
Infrared SLD Central wavelength 820 nm Output 0.6 mW Class 1 Laser product (IEC60825-1/FDA (CDRH) Part 1040.10*2) |
|||
Spot diameter |
ø20 µm ø0.000787"*3 |
|||
Linearity |
±0.3 µm ±0.000012"*4 |
|||
Resolution |
0.25 µm 0.00000984"*5 |
|||
Sampling cycle |
200 µs |
|||
Light source for guide |
Red semiconductor laser Wavelength 655 nm Output 0.1 mW Class 1 Laser product (IEC60825-1/FDA (CDRH) Part 1040.10*2) |
|||
LED display |
Target near center of measurement range: green lights. Target within measurement range: orange lights. Target outside measurement range: Flashes orange. |
|||
Temperature fluctuation |
0.01% of F.S./°C |
|||
Environmental resistance |
Ambient light |
Incandescent lamp or Fluorescent lamp: 10,000 lux max. |
||
Ambient temperature |
0 to +35 °C 32 to 95 °F |
|||
Relative humidity |
35 to 80 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 0.5 mm 0.02", 2 hours in each of the X, Y, and Z directions |
|||
Material |
Polycarbonate |
|||
Weight |
Approx. 1 kg |
|||
*1 The thickness measurement type sensor head displays the measurement range for the distance between plates of glass. Ensure that the measurement target is within the possible detection distance range. | ||||
Scroll

Specifications
Model |
SI-F80U |
|||
Type |
Thickness measurement type Spectrum unit |
|||
Measurement range |
0.05 to 1.1 mm 0.002" to 0.04" *1 |
|||
Light source |
Infrared SLD Central wavelength 820 nm Output 0.6 mW Class 1 Laser product (IEC60825-1/FDA (CDRH) Part 1040.10*2) |
|||
Spot diameter |
ø20 µm ø0.000787"*3 |
|||
Linearity |
±0.2 µm ±0.000008" *4 |
|||
Resolution |
0.001 µm *5 |
|||
Sampling cycle |
200 µs |
|||
Light source for guide |
Red semiconductor laser Wavelength 655 nm Output 0.1 mW Class 1 Laser product (IEC60825-1/FDA (CDRH) Part 1040.10*2) |
|||
LED display |
Target near center of measurement range: green lights. Target within measurement range: orange lights. Target outside measurement range: Flashes orange. |
|||
Temperature fluctuation |
0.01% of F.S./°C |
|||
Environmental resistance |
Enclosure rating |
- |
||
Ambient light |
Incandescent lamp or Fluorescent lamp: 10,000 lux max. |
|||
Ambient temperature |
0 to +35 °C 32 to 95 °F |
|||
Relative humidity |
35 to 80 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 0.5 mm 0.02", 2 hours in each of the X, Y, and Z directions |
|||
Material |
Polycarbonate |
|||
Weight |
Approx. 1 kg |
|||
*1 The thickness measurement type sensor head displays the measurement range for the distance between plates of glass. Ensure that the measurement target is within the possible detection distance range. | ||||
Scroll

Specifications
Model |
SI-F10U3 |
|||
Measurement range |
11.3 to 12.35 mm 0.04" to 0.49" *1 |
|||
Light source |
Infrared SLD Central wavelength 820 nm Output 0.6 mW Class 1 Laser product (IEC60825-1/FDA (CDRH) Part 1040.10*2) |
|||
Spot diameter |
ø40 µm ø0.001575"*3 |
|||
Linearity |
±0.3 µm ±0.000012"*4 |
|||
Resolution |
0.25 µm 0.00000984"*5 |
|||
Sampling cycle |
200 µs |
|||
Light source for guide |
Red semiconductor laser Wavelength 650 nm Output 0.1 mW Class 1 Laser product (IEC60825-1/FDA (CDRH) Part 1040.10*2) |
|||
LED display |
Target near center of measurement range: green lights. Target within measurement range: orange lights. Target outside measurement range: Flashes orange. |
|||
Temperature fluctuation |
0.01% of F.S./°C |
|||
Environmental resistance |
Ambient light |
Incandescent lamp or Fluorescent lamp: 10,000 lux max. |
||
Ambient temperature |
0 to +35 °C 32 to 95 °F |
|||
Relative humidity |
35 to 80 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 0.5 mm 0.02", 2 hours in each of the X, Y, and Z directions |
|||
Material |
Polycarbonate |
|||
Weight |
Approx. 1 kg |
|||
*1 Indicates distance from the front of the sensor head. For long distance type sensor heads there is an individual difference of up to ±0.2 mm ±0.01". | ||||
Scroll