Filters

Measurement Sensors

719 products

Showing 1 - 24 of 719 products

Showing 1 - 24 of 719 products
View
Keyence New Stock Image
Keyence GT2-P12K Keyence
Sale price $884.78
In stock, 14 units

Specifications

Model

GT2-P12K*1

Detection system

Scale Shot System II, absolute (no tracking errors) type

Measuring range

12 mm 0.47"

Resolution

0.1 μm 0.004 Mil

Indicated accuracy

1 µm 0.04 Mil (p-p)*2

Measuring force

Downward mounting

1.0 N*3

Side mounting

0.95 N*3

Upward mounting

0.9 N*3

Sampling cycle

4 ms

Mechanical response

10 Hz*2

Operation indicator light

2-color LED (red, green)

Environmental resistance

Enclosure rating

IP67G (JIS)*4, IP67 (IEC), NEMA Type 13*4

Ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

1,000 m/s2 (IEC60068-2-27)

Materials

Main body

Main body case: SUS 303, Status indicator: PET, Sensor head-relay connector cable: PUR, Relay connector: PBT

Dust boot

NBR

Contact

SUS304, cemented tungsten carbide*5

Sensor head cable

Optional (connect to relay connector)

Weight

Approx. 35 g (excluding cable)*6

*1 Note: You may not be able to connect the sensor head to the amplifier unit depending on when the amplifier unit was purchased. For details, contact your local sales office.
*2 Value when the ambient temperature is 20 °C 68 °F.
*3 Value at center of measuring range. Please note that the measurement force changes depending on the installation state of the dust boots.
*4 When an M8 oil-resistant cable (GT2-CHP2M/CHP5M/CHP10M) is used for the sensor head cable.
*5 The contact is included with the sensor.
*6 Including the relay connector.

LK-G5001V Keyence
Keyence LK-G5001V Keyence
Sale price $2,253.37
Only 5 units left

Specifications

Model

LK-G5001V*1*2

Separate type

LK-G5001/LK-HD500

Type

Main controller

Sensor head compatibility

Compatible

No. of connectable sensor heads

2

Display

Minimum display unit

LK-HD500: 0.001 µm

Display range

LK-HD500: ±999.999 µm to ±9,999.99 mm (7 settings selectable)

Display cycle

LK-HD500: Approx. 10 times/sec.

Display interface

Display port

Either the display unit (LK-HD500) or dedicated touch panel (LK-HD1001) can be connected

LED indicator

LASER ON

Terminal block

Analog output voltage

±10 V output, Output impedance: 100 Ω

Analog current output

4 to 20 mA, Maximum load resistance: 350 Ω

No. of analog outputs

2

TIMING 1 input

Non-voltage input*3

RESET 1 input

Auto-zero 1 input

Laser control input

Non-voltage input*4

Laser remote input

Non-voltage input

Alarm output

NPN open-collector output

General comparator output

Expansion connector

TIMING input

Non-voltage input

RESET input

Auto-zero input

Program switching input

Binary selection input

Alarm output

NPN open-collector output

Comparator output

Binary output

RS-232C interface

Baud rate: 9,600 to 115,200 bps
Data length: 8 bits, Stop bit length: 1 bit, Parity: None/even/odd

USB interface

USB 2.0 Hi-Speed compliant*5

Ethernet interface

100Base-TX/10Base-T*6

EtherNet/IP™interface

Cyclic communication (implicit messaging)
Message communication (explicit messaging) : UCMM and Class3 Number of connections: 32 Complies with conformance test version CT14*7

PLC-Link

The following PLCs are supported:Mitsubishi Electric: MELSEC iQ-R Series, iQ-F Series, Q Series, L Series, FX Series
EtherNet/IP™, CC-Link, and DeviceNet® cannot be used in conjunction with PLC-Link

Head expansion unit connector

Up to 10 head expansion units can be connected to one main controller

Expansion unit connector

Either of the CC-Link unit (LK-CC100) or DeviceNet® unit (LK-DN100) can be connected

Power supply

Power supply voltage

24 VDC ±10 %

Maximum current consumption

0.6 A or less with 1 head/3.5 A or less with 12 heads

Environmental resistance

Ambient temperature

When one or less head expansion unit is connected: 0 to +50 °C 32 to 122 °F.
When two or more head expansion units are connected: 0 to +40 °C 32 to 104 °F.

Relative humidity

35 to 85 % RH (No condensation)

Weight

Approx. 600 g

*1 NPN open-collector output rating: 50 mA max. (40 V max.), Residual voltage: 0.5 V max.
Non-voltage input rating: ON voltage: 1 V max., OFF current: 0.6 mA max.
*2 Part of the input/output circuit of the LK-G5000 Series is internally common. Be careful that no potential difference is generated between the internally common terminals due to the potential difference between the cables/external devices. For details, refer to "Precautions on wiring" in the User's Manual.
*3 This input is applied to all of the synchronized OUT.
*4 When the laser class 3B sensor head is connected, a key-operated switch must be used for the input to this terminal. The laser is emitted only when the key-operated switch is set to the ON position. (Select a key which can be removed only when it is set to the OFF position.)
When the laser class 2/3R sensor head is connected, the laser turns on when this terminal is opened and turns off when it is short-circuited.
*5 When a PC supporting USB 1.1 or USB 2.0 full speed is connected, the data refresh cycle and other operations may slow down.
*6 Use the Ethernet interface only for direct connections with a PC or for local network connections with a PC or LK-G5000 Series units.
*7 The EtherNet/IP™ interface cannot be used when a CC-Link unit or a DeviceNet® unit is installed.
EtherNet/IP™ is supported by the latest controllers. For details on which controllers support EtherNet/IP™ , contact your nearest KEYENCE office.

LK-G5001 Keyence
Keyence LK-G5001 Keyence
Sale price $1,872.36
Only 6 units left

Specifications

Model

LK-G5001

Type

Separate type Main controller

Sensor head compatibility

Compatible

No. of connectable sensor heads

2

Display

Minimum display unit

0.001 µm

Display range

±999.999 µm to ±9999.99 mm (7 settings selectable)

Display cycle

Approx 10 times/sec.

Display interface

Display port

Either the display unit (LK-HD500) or dedicated touch panel (LK-HD1001) can be connected

LED indicator

LASER ON

Terminal block

Analog output voltage

±10 V output, Output impedance: 100 Ω*1

Analog current output

4 to 20 mA, Maximum load resistance: 350 Ω*1

No. of analog outputs

2*1

TIMING 1 input

Non-voltage input*2

RESET 1 input

Auto-zero 1 input

Laser remote input

Non-voltage input*1

Alarm output

NPN open-collector output*1

General comparator output

Expansion connector

TIMING input

Non-voltage input*1

RESET input

Auto-zero input

Program switching input

Binary selection input

Alarm output

NPN open-collector output*1

Comparator output

Binary output

RS-232C interface

Baud rate: 9600 to 115200 bps
Data length: 8 bits Stop bit length: 1 bit Parity: None/even/odd

USB interface

USB 2.0 Hi-Speed compliant*3

Ethernet interface

100Base-TX/10Base-T*4

EtherNet/IP™interface

Cyclic communication (implicit messaging)
Message communication (explicit messaging) : UCMM and Class3 Number of connections: 32 Complies with conformance test version CT14*5

PLC-Link

The following PLCs are supported:Mitsubishi Electric: MELSEC iQ-R Series, iQ-F Series, Q Series, L Series, FX Series
EtherNet/IP™, CC-Link, and DeviceNet® cannot be used in conjunction with PLC-Link

Head expansion unit connector

Up to 10 head expansion units can be connected to one main controller

Expansion unit connector

Either of the CC-Link unit (LK-CC100) or DeviceNet® unit (LK-DN100) can be connected

Power supply

Power supply voltage

24 VDC ±10%

Maximum current consumption

0.6 A or less with 1 head/3.5 A or less with 12 heads

Environmental resistance

Ambient temperature

When one or less head expansion unit is connected: 0 to +50 °C 32 to 122 °F.
When two or more head expansion units are connected: 0 to +40 °C 32 to 104 °F.

Relative humidity

35 to 85 % RH (No condensation)

Weight

Approx. 600 g

*1 NPN open-collector output rating: 50 mA max. (40 V max.), Residual voltage: 0.5 V max.
PNP open-collector output rating: 50 mA max. (30 V max.), Residual voltage: 0.5 V max.
Non-voltage input rating: ON voltage: 1 V max., OFF current: 0.6 mA max.
Voltage input rating: Maximum input rating: 26.4 V, ON voltage: 10.2 V, OFF current: 0.6 mA
Part of the input/output circuit of the LK-G5000 Series is internally common. Be careful that no potential difference is generated between the internally common terminals due to the potential difference between the cables/external devices. For details, refer to "Precautions on wiring" in the User's Manual.
*2 NPN open-collector output rating: 50 mA max. (40 V max.), Residual voltage: 0.5 V max.
PNP open-collector output rating: 50 mA max. (30 V max.), Residual voltage: 0.5 V max.
Non-voltage input rating: ON voltage: 1 V max., OFF current: 0.6 mA max.
Voltage input rating: Maximum input rating: 26.4 V, ON voltage: 10.2 V, OFF current: 0.6 mA
Part of the input/output circuit of the LK-G5000 Series is internally common. Be careful that no potential difference is generated between the internally common terminals due to the potential difference between the cables/external devices. For details, refer to "Precautions on wiring" in the User's Manual. This input is applied to all of the synchronized OUT.
*3 When a PC supporting USB 1.1 or USB 2.0 full speed is connected, the data refresh cycle and other operations may slow down.
*4 Use the Ethernet interface only for direct connections with a PC or for local network connections with a PC or LK-G5000 Series units.
*5 The EtherNet/IP™ interface cannot be used when a CC-Link unit or a DeviceNet® unit is installed.
EtherNet/IP™ is supported by the latest controllers. For details on which controllers support EtherNet/IP™ , contact your nearest KEYENCE office.

Keyence New Stock Image
Keyence GT2-H12K Keyence
Sale price $595.28
In stock, 18 units

Specifications

Model

GT2-H12K

Detection system

Quartz glass scale, CMOS image sensor projection system, Absolute type (without tracking error)

Measuring range

12 mm 0.47"

Resolution

0.1 μm 0.004 Mil

Indicated accuracy

1 µm 0.04 Mil (p-p)*1

Measuring force

Downward mounting

1.0 N*2

Side mounting

0.9 N*2

Upward mounting

0.8 N*2

Sampling cycle

1 ms

Mechanical response

10 Hz*1

Operation indicator light

2-color LED (red, green)

Environmental resistance

Enclosure rating

IP67

Ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

1,000 m/s2 (IEC60068-2-27)

Materials

Main body

Main body cast: Zinc die-casting, Indicator: Polyarylate, Dust boot: NBR

Dust boot

NBR

Contact

TYPE304 Stainless steel, super-tough tungsten alloy*3

Sensor head cable

Optional (connect to the M8 connector)

Weight

Approx. 95 g (excluding cable)

*1 Value when the ambient temperature is 20 °C 68 °F.
*2 Value at center of measuring range. Please note that the measurement force changes depending on the installation state of the dust boots.
*3 The contact is included with the sensor.

Keyence New Stock Image
Keyence GT2-H12 Keyence
Sale price $522.89
In stock, 15 units

Specifications

Model

GT2-H12

Detection system

Quartz glass scale, CMOS image sensor projection system, Absolute type (without tracking error)

Measuring range

12 mm 0.47"

Resolution

0.5 μm 0.02 Mil

Indicated accuracy

2 µm 0.08 Mil (p-p)*1

Measuring force

Downward mounting

1.0 N*2

Side mounting

0.9 N*2

Upward mounting

0.8 N*2

Sampling cycle

1 ms

Mechanical response

10 Hz*1

Operation indicator light

2-color LED (red, green)

Environmental resistance

Enclosure rating

IP67

Ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

1,000 m/s2 (IEC60068-2-27)

Materials

Main body

Main body cast: Zinc die-casting, Indicator: Polyarylate, Dust boot: NBR

Dust boot

NBR

Contact

TYPE304, 440C Stainless steel*3

Sensor head cable

Optional (connect to the M8 connector)

Weight

Approx. 95 g (excluding cable)

*1 Value when the ambient temperature is 20 °C 68 °F.
*2 Value at center of measuring range. Please note that the measurement force changes depending on the installation state of the dust boots.
*3 The contact is included with the sensor.

Keyence New Stock Image
Keyence GT2-A50 Keyence
Sale price $1,111.83
In stock, 13 units

Specifications

Model

GT2-A50

Detection system

Quartz glass scale, CMOS image sensor projection system, Absolute type (without tracking error)

Measuring range

50 mm 1.97"

Resolution

0.5 μm 0.02 Mil

Indicated accuracy

3.5 µm 0.14 Mil (p-p)*1

Measuring force

Downward mounting

3.2 N*2

Side mounting

2.8 N*2

Upward mounting

2.4 N*2

Sampling cycle

1 ms

Operation indicator light

2-color LED (red, green)

Environmental resistance

Enclosure rating

IP67*3

Pressure resistance

1 MPa

Applied pressure range

0.25 to 0.5 MPa

Ambient temperature

0 to +55 °C 32 to 131 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions*4

Materials

Main body

Main body case: Zinc die-casting; Cylinder part: Aluminium alloy;
Air joint resin part: Polyacetal; Air joint metal part: Brass nickel plating; Indicator: Polyarylate

Dust boot

NBR

Contact

TYPE304, 440C Stainless steel*5

Sensor head cable

Optional (connect to the M8 connector)

Weight

Approx. 405 g (excluding cable)

*1 Value when the ambient temperature is 20 °C 68 °F.
*2 Value at center of measuring range. Please note that the measurement force changes depending on the installation state of the dust boots.
*3 Make sure the air tube is connected to the air exhaust joint and that no foreign materials enter inside from the joint.
*4 In the case where a mounting bracket D is used with GT2-A32 and GT2-A50, the double amplitude becomes 0.75 mm 0.03".
*5 The contact is included with the sensor.

Keyence New Stock Image
Keyence IG-028 Keyence
Sale price $967.65
In stock, 17 units

Specifications

Model

IG-028

Operation principle

CCD method

Light source

Wavelength

660 nm (Visible light semiconductor laser)

FDA

Class 1*1

IEC/JIS

Class 1

Mounting distance

0 to 1500 mm 59.06"

Measurement range

28 mm 1.10"

Sampling cycle

980 µs (When the number of times for averaging is set to [hsp]: 490 µs)

Minimum detectable object

High sensitivity mode

ø0.1 mm ø0.003" (Setting distance: 100 mm 3.94")*2

Standard mode

ø0.2 mm ø0.007" (Setting distance: 50 mm 1.97" or less),
ø0.5 mm ø0.02" (Setting distance: 500 mm 19.68")*2

Repeatability

5 µm 0.20 Mil (Setting distance: 100 mm 3.94")
10 µm 0.39 Mil (Setting distance: 500 mm 19.68")
80 µm 3.15 Mil (Setting distance: 1,000 mm 39.37")
140 µm 5.51 Mil (Setting distance: 1,500 mm 59.06")*3

Linearity

±0.1 % of F.S. (±28 µm ±1.10 Mil)*4

Temperature characteristics

±0.01 % of F.S./°C (±3 µm ±0.12 Mil/°C)*5

Operation indicator

Transmitter

Optical axis alignment indicator: Green LED, Power indicator: Green LED

Receiver

Optical axis alignment indicator: Green LED, Position monitor: Dual bar LED (Red, Green)

Environmental resistance

Enclosure rating

IP67

Ambient light

Incandescent lamp: 5,000 lux, Sunlight: 5,000 lux*6

Ambient temperature

-10 to +45 °C 14 to 113 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z axis

Material

Case

Zinc die-cast (Lower case), PBT (Upper case), Polyarylate (PAR) (Display part), SUS304 (Metallic part)

Lens cover

Glass

Cable

PVC

Accessories

Transmitter × 1, Receiver × 1, Sensor head cables (2 m 6.56') × 2

Weight

Approx. 500 g (including supplied items)

*1 The classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice.
*2 When the measurement target object is measured at the center position of the setting distance. When the measurement mode is set to the glass edge mode, a glass edge of C0.1 mm 0.003" or more can be detected (Setting distance: 500 mm 19.69").
*3 When the light is shielded by half at the center position of the setting distance. Vibration width when the average number of times is set to 16 and sampling is performed for 30 seconds. (When the analog output is used, the margin of error of analog output is added.)
*4 When the setting distance is 100 mm 3.94" and light is shielded at 50 mm 1.96"position from the receiver. Margin of error to the ideal line.
*5 When the setting distance is 100 mm 3.94" and light is shielded by half at 50 mm 1.96" position from the receiver.
*6 Excluding when the average number of times is set to [hsp].

Keyence New Stock Image
Keyence IL-600 Keyence
Sale price $740.03
Only 10 units left

Specifications

Model

IL-600

Reference distance

600 mm 23.62"

Measurement range

200 to 1000 mm 7.87" to 39.37"

Light source

Type

Red semiconductor laser, wavelength: 655 nm (visible light)

Laser class

Class 2 (FDA (CDRH) Part1040.10)*1
Class 2 (IEC 60825-1)

Output

560 µW

Spot diameter (at standard distance)

Approx. ø1.6 mm ø0.06"

Linearity

±0.25% of F.S. (200 to 600 mm 7.84" to 23.62")*2*3
±0.5% of F.S. (200 to 1000 mm 7.84" to 39.37")*2*3

Repeatability

50 µm*4

Sampling rate

0.33/1/2/5 ms (4 levels available)

Operation status indicators

Laser emission warning indicator: Green LED, Analog range indicator: Orange LED, Reference distance indicator: Red/Green LED

Temperature characteristics

0.08% of F.S./°C*5

Environmental resistance

Enclosure rating

IP67

Pollution degree

3

Ambient light

Incandescent lamp: 5,000 lux*6

Ambient temperature

-10 to +50 °C 14 to 122 °F (No condensation or freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Housing material: PBT, Metal parts: SUS304, Packing: NBR, Lens cover: Glass, Cable: PVC

Weight

Approx. 135 g

*1 The laser classification for FDA (CDRH) is implemented based on IEC 60825-1 in accordance with the requirements of Laser Notice.
*2 Value when measuring the KEYENCE standard target (white diffuse object).
*3 F.S. of each model is as follows. IL-030: ±5 mm ±0.20" IL-065: ±10 mm ±0.39" IL-100: ±20 mm ±0.79" IL-300: ±140 mm ±5.51" IL-600: ±400 mm ±15.75" IL-2000: +1000 to -1500 mm 39.37" to -59.05"
*4 Value when measuring the KEYENCE standard target (white diffuse object) at the reference distance, sampling rate: 1 ms, and average number of times: 128. For the IL-300/IL-600, the sampling rate is 2 ms. For the IL-2000, the sampling rate is set to 5ms.
*5 F.S. of each model is as follows. IL-030: ±5 mm ±0.20" IL-065: ±10 mm ±0.39" IL-100: ±20 mm ±0.79" IL-300: ±140 mm ±5.51" IL-600: ±400 mm ±15.75"
*6 Value when the sampling rate is set to 2 ms or 5 ms.

Keyence New Stock Image
Keyence IL-2000 Keyence
Sale price $1,405.11
In stock, 17 units

Specifications

Model

IL-2000*1

Reference distance

2000 mm 78.74"

Measurement range

1000 to 3500 mm 39.37" to 137.80"

Light source

Type

Red semiconductor laser, wavelength: 655 nm (visible light)

Laser class

Class 2 (FDA (CDRH) Part1040.10)*2
Class 2 (IEC 60825-1)

Output

560 µW

Spot diameter (at standard distance)

Approx. 1400 × 7000 µm

Linearity

±0.16% of F.S. (1000 to 3500 mm 39.37" to 137.80")*3*4

Repeatability

100 µm*5

Sampling rate

0.33/1/2/5 ms (4 levels available)

Operation status indicators

Laser emission warning indicator: Green LED, Analog range indicator: Orange LED, Reference distance indicator: Red/Green LED

Temperature characteristics

0.016% of F.S./°C*6

Environmental resistance

Enclosure rating

IP67

Pollution degree

3

Ambient light

Incandescent lamp: 10,000 lux*7

Ambient temperature

-10 to +50 °C 14 to 122 °F (No condensation or freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Housing material: PBT, Metal parts: SUS304, Packing: NBR, Lens cover: Glass, Cable: PVC

Weight

Approx. 350 g

*1 Amplifiers purchased before August 8th, 2012 cannot be used.
*2 The laser classification for FDA (CDRH) is implemented based on IEC 60825-1 in accordance with the requirements of Laser Notice.
*3 Value when measuring the KEYENCE standard target (white diffuse object).
*4 F.S. of each model is as follows. IL-030: ±5 mm ±0.20" IL-065: ±10 mm ±0.39" IL-100: ±20 mm ±0.79" IL-300: ±140 mm ±5.51" IL-600: ±400 mm ±15.75" IL-2000: +1000 to -1500 mm 39.37" to -59.05"
*5 Value when measuring the KEYENCE standard target (white diffuse object) at the reference distance, sampling rate: 1 ms, and average number of times: 128. For the IL-300/IL-600, the sampling rate is 2 ms. For the IL-2000, the sampling rate is set to 5ms.
*6 F.S. of each model is as follows. IL-030: ±5 mm ±0.20" IL-065: ±10 mm ±0.39" IL-100: ±20 mm ±0.79" IL-300: ±140 mm ±5.51" IL-600: ±400 mm ±15.75"
*7 Value when the sampling rate is set to 2 ms or 5 ms.

Keyence New Stock Image
Keyence IL-030 Keyence
Sale price $498.77
In stock, 16 units

Specifications

Model

IL-030

Reference distance

30 mm 1.18"

Measurement range

20 to 45 mm 0.79" to 1.77"

Light source

Type

Red semiconductor laser, wavelength: 655 nm (visible light)

Laser class

Class 1 (FDA (CDRH) Part1040.10)*1
Class 1 (IEC 60825-1)

Output

220 µW

Spot diameter (at standard distance)

Approx. 200 × 750 µm

Linearity

±0.1% of F.S. (25 to 35 mm 0.98" to 1.38")*2*3

Repeatability

1 µm*4

Sampling rate

0.33/1/2/5 ms (4 levels available)

Operation status indicators

Laser emission warning indicator: Green LED, Analog range indicator: Orange LED, Reference distance indicator: Red/Green LED

Temperature characteristics

0.05% of F.S./°C*5

Environmental resistance

Enclosure rating

IP67

Pollution degree

3

Ambient light

Incandescent lamp: 5,000 lux*6

Ambient temperature

-10 to +50 °C 14 to 122 °F (No condensation or freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Housing material: PBT, Metal parts: SUS304, Packing: NBR, Lens cover: Glass, Cable: PVC

Weight

Approx. 60 g

*1 The laser classification for FDA (CDRH) is implemented based on IEC 60825-1 in accordance with the requirements of Laser Notice.
*2 Value when measuring the KEYENCE standard target (white diffuse object).
*3 F.S. of each model is as follows. IL-030: ±5 mm ±0.20" IL-065: ±10 mm ±0.39" IL-100: ±20 mm ±0.79" IL-300: ±140 mm ±5.51" IL-600: ±400 mm ±15.75" IL-2000: +1000 to -1500 mm 39.37" to -59.05"
*4 Value when measuring the KEYENCE standard target (white diffuse object) at the reference distance, sampling rate: 1 ms, and average number of times: 128. For the IL-300/IL-600, the sampling rate is 2 ms. For the IL-2000, the sampling rate is set to 5ms.
*5 F.S. of each model is as follows. IL-030: ±5 mm ±0.20" IL-065: ±10 mm ±0.39" IL-100: ±20 mm ±0.79" IL-300: ±140 mm ±5.51" IL-600: ±400 mm ±15.75"
*6 Value when the sampling rate is set to 2 ms or 5 ms.

Keyence New Stock Image
Keyence OP-87443 Keyence
Sale price $112.76
Only 9 units left

Specifications

Model

OP-87443

Type

Monitor power cable

Cable end

M8 4-pin / Strand wire

Length

2 m 6.6'

LK-G3001 Keyence
Keyence LK-G3001 Keyence
Sale price $1,237.31
In stock, 41 units

Specifications

Model

LK-G3001*1

Type

Separate monitor model*2

Display

Head compatibility

All LK-G sensor heads are compatible

Number of connectable sensors

Maximum of 2 units

Minimum display unit

0.01 µm

Display range

±9,999.99 mm to ±9,999.99 µm (Selectable from six levels)

Refresh rate

10 times/sec

Terminal block

Analog voltage output

±10 V x 2 outputs, output impedance: 100 Ω

Analog current output

4 to 20 mA x 2 outputs, maximum load resistance: 350 Ω

Timing input

For OUT1, non-voltage input

Reset input

Auto-zero input

Laser remote interlock input

Non-voltage input

Comparator output

For OUT1, NPN open-collector output

Alarm output

For OUT1, NPN open-collector output (N.C.)

Expansion connector

Timing input

For OUT2, non-voltage input

Reset input

Auto-zero input

Program switching input

Non-voltage input x 3 inputs

Laser-Off input

For Head A/Head B, non-voltage input

Comparator output

For OUT2, NPN open-collector output

Alarm output

For OUT2, NPN open-collector output (N.C.)

Binary

Binary output

Measured data output (21 bits), OUT1/OUT2 selectable, NPN open-collector output

Strobe output

NPN open-collector output

Binary selector output

Binary selector input

Non-voltage input

RS-232C interface

Measured data output and control input/output (Maximum baud rate: 115,200 bps, selectable)

USB interface

In conformity with USB Revision 2.0 Full speed (USB1.1 compatible)

Major functions

2 OUT simultaneous measurement, Operation, Averaging, Filter, Calibration, Measurement, AUTO ZERO,
Sampling frequency setting, Mutual interference prevention, Data storage, 8-program memory, ECO mode,
ABLE setting, Target setting, ABLE tuning, Selection of measurement surface of transparent target,
Statistics processing, Connection of setting support software, Selectable head-mounting, etc.

Rating

Power voltage

24 VDC ±10 %, Ripple (P-P) 10 % or less

Current consumption

500 mA or less with 1 head/600 mA or less with 2 heads

Environmental resistance

Ambient temperature

0 to +50 °C 32 to 122 °F

Relative humidity

35 to 85 % RH (No condensation)

Weight

Approx. 370 g

*1 The rating of the NPN open-collector: 50 mA max. (40 V max.), residual voltage of 1 V max.
The rating of non-voltage input: 1 V or less ON voltage, 0.6 mA or less OFF current.
*2 LK-G3001 can be operated singly. The measured value display and setting modifications can be performed on the display panel (LK-GD500) or via the setting support software (LK-H1W).

Keyence Stock Image
Keyence LK-HD500 Keyence
Sale price $439.32
Only 6 units left

Specifications

Model

LK-HD500

Type

Display unit

Supported models

LK-G5000
LK-G5000P

Display

Minimum display unit

0.001 µm

Display range

±999.999 µm to ±9,999.99 mm (selectable from 7 levels)

Display cycle

10 times/sec.

LK-H152 Keyence
Keyence LK-H152 Keyence
Sale price $3,823.69
Only 8 units left

Specifications

Model

LK-H152

Mounting mode

Diffuse reflective / Specular reflective*1

Reference distance

Diffuse reflective: 150 mm 5.91"
Specular reflective: 147.5 mm 5.81"

Measuring range

Diffuse reflective: ±40 mm ±1.57"
Specular reflective: -39.5 mm to +24.4 mm -1.56" to +0.96"*2

Light source

Type

Red semiconductor laser

Wavelength

655nm

Laser class

IEC 60825-1: Class 2
FDA(CDRH)21CFR Part 1040.10: Class II

Output

0.95mW

Spot diameter (at standard distance)

ø120 µm

Linearity

±0.02% of F.S. (F.S.= 80 mm 3.15")*3

Repeatability

0.25 µm*4

Sampling cycle

2.55/5/10/20/50/100/200/500/1000 µs (9 steps selectable)

Temperature characteristics

0.01% of F.S. (F.S.= 80 mm 3.15")

Environmental resistance

Enclosure rating

IP67

Ambient light

Incandescent lamp or fluorescent lamp: 5,000 lux max.

Ambient temperature

0 to +50 °C 32 to 122 °F*5

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Aluminum die-cast

Weight

Approx. 300 g

*1 Use one of the following dark filters when measuring a transparent or mirror surface object: LK-H082/LK-H087: LK-F3, LK-H152/LK-H157: LK-F2
*2 Measurement range when the sampling cycle is 20 µs or more.
*3 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008/LK-H008W) is measured in the normal measurement mode.
*4 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008/LK-H008W) is measured at the reference distance with the number of averaging measurements set to 16384. The value in parentheses is a typical e x ample of a measurement with the number of averaging measurements set to 65536 and the sampling cycle to 200 µs.
*5 When the ambient temperature rises to 40 °C 104 °F or more, mount this on a metal plate before use.

LK-H050 Keyence
Keyence LK-H050 Keyence
Sale price $2,888.41
Only 7 units left

Specifications

Model

LK-H050

Mounting mode

Diffuse reflective

Reference distance

50 mm 1.97"

Measuring range

±10 mm ±0.39"*1

Light source

Type

Red semiconductor laser

Wavelength

655nm

Laser class

IEC 60825-1: Class 3R
FDA(CDRH)21CFR Part 1040.10: Class IIIa

Output

4.8mW

Spot diameter (at standard distance)

ø50 µm

Linearity

±0.02% of F.S. (F.S.= 20 mm 0.79")*2

Repeatability

0.025 µm*3

Sampling cycle

2.55/5/10/20/50/100/200/500/1000 µs (9 steps selectable)

Temperature characteristics

0.01% of F.S./°C (F.S.= 20 mm 0.79")

Environmental resistance

Enclosure rating

IP67

Ambient light

Incandescent lamp or fluorescent lamp: 10,000 lux max.

Ambient temperature

0 to +50 °C 32 to 122 °F*4

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Aluminum die-cast

Weight

Approx. 260 g

*1 Measurement range when the sampling cycle is 20 µs or more.
*2 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008/LK-H008W) is measured in the normal measurement mode.
*3 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008/LK-H008W) is measured at the reference distance with the number of averaging measurements set to 16384. The value in parentheses is a typical e x ample of a measurement with the number of averaging measurements set to 65536 and the sampling cycle to 200 µs.
*4 When the ambient temperature rises to 40 °C 104 °F or more, mount this on a metal plate before use.

keyence Stock Image
Keyence CL-C5 Keyence
Sale price $750.00
Only 5 units left

Specifications

Model

CL-C5

Length

5 m 16.4'

Weight

450 g

keyence Stock Image
Keyence CL-L015N Keyence
Sale price$0.00
Sold Out

Specifications

Model

CL-L015N

Type

Optical unit

Head

CL-L015 *1

Reference distance

15 mm 0.59"

Reference measurement range

Measurement range

±1.3 mm ±0.05"

Linearity

±0.49 μm ±0.000019" *2

High precision measurement range

Measurement range

±0.5 mm ±0.02"

Linearity

±0.41 μm ±0.000016" *2

Resolution

0.25 μm 0.000010" *3

Spot diameter

ø300 μm ø0.0118"

Laser class

Optical unit

Class I

Sampling cycle

100/200/500/1000 μs (Adjustable 4-stage)

Environmental resistance

Enclosure rating

Head

IP67 (IEC60529)

Ambient light

Target surface illuminance: 30000 lux (Incandescent lamp)

Ambient temperature

0 to 50°C 32 to 122°F

Relative humidity

85% RH or less (no condensation)

Vibration resistance

Head

10 to 57 Hz, double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axes

Optical unit

10 to 57 Hz, double amplitude 0.3 mm 0.01"; 2 hours each for X, Y, and Z axes

Shock resistance

15 G, 6 ms

Temperature characteristic

Head

0.005% of F.S./°C

Optical unit

0.015% of F.S./°C

Material

Head

Front: SUS, Rear: Aluminum

Optical unit

Polycarbonate

Weight

Head

Approx. 180 g 6.35 oz

Optical unit

Approx. 1600 g 3.53 lb

*1 Sensor head and optical unit are a matched pair. Not cross compatible.
*2 Value measured in displacement mode with KEYENCE reference workpiece (mirrored surface).
*3 Value measured using 16,384 average cycles with KEYENCE reference workpiece (mirrored surface).

Keyence Stock Image
Keyence CL-3000 Keyence
Sale price $1,992.26
Only 6 units left

Specifications

Model

CL-3000

Type

Controller

Number of optical unit connections

Controller only: 2 units; using expansion units / relay units: 6 units

Interface

EtherNet/IP™

Supports cyclic communication and message communication; RPI: 1 to 10,000 ms (0.5 ms units)
Maximum number of connections: 8, complies with Version CT14 conformance test
Cannot be used when using PROFINET, PLC link or EtherCAT

PROFINET

Compatible with conformance class A. Cannot be used when using EtherNet/IP™, PLC link or EtherCAT

PLC-Link

The following PLCs are supported:
Mitsubishi Electric: MELSEC iQ-R Series, iQ-F Series, Q Series, L Series, FX Series
Cannot be used when using EtherNet/IP™, PROFINET or EtherCAT

Ethernet

Allows for measurement data output and control I/O via no-protocol command communication with PCs and PLCs
100Base-TX, capable of communication with CL-NavigatorN*1

USB

Conforms to USB 2.0 HighSpeed, capable of communication with CL-NavigatorN*1

RS-232C

Allows for measurement data output and control I/O via no-protocol command communication with PCs and PLCs
Baud rate: 9600 to 115,200 bps, data length: 8 bit, stop bit: 1 bit, parity: none / even numbers / odd numbers

Terminal (IN)

13 (supports function switching via software)

Terminal (OUT)

11 *2(supports function switching via software)

Ratings

Power voltage

24 VDC ±10%

Maximum current consumption

With 1 optical unit connected: 0.86 A, with 4 optical units connected: 3.3 A, with 6 optical units connected: 4.5 A

Environmental resistance

Ambient temperature

0 to 50°C 32 to 122°F

Relative humidity

20% RH to 85% RH (no condensation)

Vibration resistance

10 to 57 Hz, double amplitude 0.3 mm 0.01"; 2 hours each for X, Y, and Z axes

Monitor/Setting support software

CL-NavigatorN

Weight

Approx. 600 g

CL-NavigatorN OS environment

Supported OS

Windows 11 Pro / Windows 10 *3 / Windows 7 *4

CPU

Celeron Dualcore 1.7 GHz or higher

Memory capacity

4 GB or more

Required free space on hard disk

1 GB or more

Display resolution

XGA (1024 x 768 pixels) or higher

*1 Sample DLL and LabVIEW programs are available. Contact your local sales office for details.
*2 Positive common connection is supported for NPN input devices, and negative common connection for PNP input devices.
*3 Home, Pro and Enterprise Editions are supported.
*4 Home Premium, Professional and Ultimate Editions are supported.
• Windows and Excel are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries.

keyence Stock Image
Keyence LJ-H3 Keyence
Sale price $556.88
Only 4 units left

Specifications

Model

LJ-H3

Type

Setup/Monitor software

Operating System

Windows 11 Pro
Windows 10 *1
Windows 7 (SP1 or later)*2
Windows Vista (SP2 or later)*3
Windows XP (SP3 or later)*4

Supported languages

English, Japanese, German, French, Simplified Chinese, Traditional Chinese

CPU

Core i3 2.3 GHz or faster

Memory capacity

2GB or more

L2 cache memory

2MB or more

Available hard disk space

10 GB or more

Display

XGA (1024×768 pixel) or more, 256-colors or more

PC interface

Any one of the following must be loaded.
USB2.0/1.1*5, Ethernet 1000BASE-T/100BASE-TX*6

Weight

Approx. 400 g

*1 Compatible with each edition of Home, Pro, and Enterprise.
*2 Compatible with Home Premium, Professional, and Ultimate editions.
*3 Compatible with Ultimate, Business, Home Premium, and Home Basic editions.
*4 Compatible with Home Premium and Professional editions.
*5 Connection through a USB hub or converter is not guaranteed.
*6 Connections with a LAN through a router or converter are not guaranteed.

Keyence New Stock Image
Keyence LJ-V7060 Keyence
Sale price $1,228.44
In stock, 11 units

Specifications

Model

LJ-V7060

Mounting conditions

Diffuse reflection

Reference distance

60 mm 2.36"

Measurement range

Z-axis (height)

±8 mm 0.31"
(F.S.=16 mm 0.63")

X-axis (width)

NEAR side

13.5 mm 0.53"

Reference distance

15 mm 0.59"

Far side

Light source

Type

Blue semiconductor laser

Wavelength

405 nm (visible beam)

Laser class

Class 2M Laser Product*1
(IEC60825-1, FDA(CDRH) Part 1040.10*2)

Output

10 mW

Spot size (reference distance)

Approx. 21 mm × 45 µm
0.83" × 0.001772"

Repeatability

Z-axis (height)

0.4 µm 0.000016"*3*4

X-axis (width)

5 µm 0.000197"*3*5

Linearity

Z-axis (height)

±0.1% of F.S.*6

Profile data interval

X-axis (width)

20 µm 0.0008"

Sampling cycle (trigger interval)

Top speed: 16 µs (high-speed mode), Top speed: 32 µs (advanced function mode)*7

Temperature characteristics

0.01% of F.S./°C

Environmental resistance

Enclosure rating

IP67 (IEC60529)*8

Ambient light

Incandescent lamp: 10,000 lux max.*9

Ambient temperature

0 to +45 °C 32 to 113 °F*10

Relative humidity

85% RH or less (no condensation)

Vibration resistance

10 to 57 Hz, Double amplitude 1.5 mm 0.06", 3 hours in each of the X, Y, and Z directions

Shock resistance

15 G/6 ms

Material

Aluminum

Weight

Approx. 450 g

*1 Do not look into the beam directly using any optical instruments (such as eye loupes, magnifiers, microscopes, telescopes, or binoculars).
Viewing the laser output with an optical instrument may pose an eye hazard.
*2 The laser classification for FDA(CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice.
*3 This value is from a case in which measurement has been performed with a reference distance with 4,096 times of averaging.
*4 The measurement targets are KEYENCE standard targets. This value is from a case in which the average height of the default setting area has been measured in height mode. All other settings are default.
*5 The measurement target is a pin gauge. This value is from a case in which the position of the intersection between the rounded surface of the pin gauge and the edge level has been measured in position mode. All other settings are default.
*6 The measurement targets are KEYENCE standard targets. The profile data is from a case in which measurement has been performed with 64 times of smoothing and 8 times of averaging. All other settings are default.
*7 For high-speed mode, when the measurement area is at its minimum, binning is ON, image capture mode is set to standard, and parallel image capture is ON.
All other settings are default. For advanced function mode, when the measurement area is at its minimum, binning is ON and image capture mode is set to standard. All other settings are default.
*8 This value is from a case in which the sensor head cable (CB-B*) or extension cable (CB-B*E) has been connected.
*9 This is the illuminance for the light-receiving surface of the sensor head during white paper measurement when light has been shined onto the white paper.
*10 The sensor head must be mounted on a metal plate for use.

Keyence Stock Image
Keyence LJ-V7001 Keyence
Sale price $862.17
Only 9 units left

Specifications

Model

LJ-V7001

Number of connectable sensors

Max. 2 units

Display

Minimum
displayable unit

0.1 µm, 0.00001 mm2, 0.01°

Maximum display range

±9999.99 mm 393.7", ±9999.99 mm2

Input terminal block

Laser remote interlock input

No-voltage input*1

Input
terminal block

Encoder input

NPN open collector output/PNP open collector output (5V / 12V / 24V) line driver output

Input terminal block

Trigger input

No-voltage input*1

Timing 1,2 input

Auto-zero 1,2 input

Input
terminal block

Reset 1, 2 input

Input terminal
block

Start measurement/stop input

Start storage/stop input

Clear memory input

Laser OFF input

Program switch input

No-voltage input x 4 inputs*1

Output terminal block

Analog voltage output

±10 V x 2 outputs, Output impedance: 100 Ω

Output
terminal block

OUT comparator output

NPN open collector output x 12 outputs*2
(Can freely assign 16 OUTs x 3 stage judgment results)

Strobe output

NPN open collector output*2

Disable trigger output

Memory FULL output

Ready output

Output terminal block

Error output

NPN open collector output (N.C.)*2

PC interface

Ethernet

1000BASE-T/100BASE-TX*3

USB

USB 2.0 high speed compliant (USB 1.1 Full-SPEED compatible)*3

RS232C

Measurement data output and control I/O (Can select a baud rate of up to 115,200 bits/s)

Rating

Power voltage

24 VDC ±10 %, including Ripple (P-P)

Current consumption

1.3 A or less when connected to 1 head
1.9 A or less when connected to 2 heads

Environmental resistance

Ambient temperature

0 to +50 °C 32 to 122 °F

Relative humidity

85% RH or less (no condensation)

Weight

Approx. 1,500 g

*1 The rating for non-voltage input is up to 1 V for ON voltage and up to 0.6 mA for OFF current
*2 The rating for NPN open-collector output is up to 50 mA (40 V or less), residual voltage of up to 1 V
*3 DLL and LabVIEW programs are available. Contact your local sales office for details.

Keyence Stock Image
Keyence OP-84327 Keyence
Sale price $138.48
Only 8 units left

Specifications

Model

OP-84327

Type

Head mounting bracket

Applicable product

GT2-H32/GT2-H50

Note

Sold separately

Keyence Stock Image
Keyence OP-77679 Keyence
Sale price $130.04
Only 8 units left

Specifications

Model

OP-77679

Applicable product

GT Series/GT2 Series

Note

This is a flat-plate-type contact (sold separately). This contact can be used to perform detections using the peaks of the bumps of the target.

Keyence New Stock Image
Keyence GT2-71MCN Keyence
Sale price $349.76
Only 8 units left

Specifications

Model

GT2-71MCN

Mounting method

DIN-rail mount

Output

NPN output

Main unit/expansion unit

Main unit

Power supply voltage

20 to 30 VDC, including 10 % ripple (P-P), Class 2*1

Power consumption

Normal

2,700 mW max. (30 V, 90 mA max.)

Power saving (Eco)

2,200 mW max. (30 V, 73.3 mA max.)

Display power

Measured value display

6 + 1/2-digit 7-segment LED (red)

Other displays

2-color, 13-level bar LED display (red, green), indicators (red, green)

Display range

-199.999.9 to 199.999.9

Display resolution

0.1 μm 0.004 Mil

Control input

Timing/preset/
reset/bank input

No-voltage input

Control output

HH/HI/GO/LO/LL

NPN open collector, 40 V 50 mA or less, residual voltage 1 V or less*1*2

Analog output

4 to 20 mA, maximum load resistance: 350 Ω
Analog output range can be changed as desired.

Response time

hsp(3)/5/10/100/500/1,000 ms
(When using GT2-Pxxx, hsp(12)/20/40/400/2,000/4,000 ms)

Environmental resistance

Ambient temperature

-10 to +50 °C 14 to 122 °F (GT2-71MCN/71MCP: -10 to +45 °C 14 to 113 °F when expansion unit (s) is connected)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Main body case: Polycarbonate, Key top: Polyacetal, Front sheet: PET, Cable: PVC

Weight

Approx. 70 g

*1 When adding expansion units, there are the following restrictions according to the number of connected units.
[When 2 to 8 units are connected including the main unit]
Power supply voltage: 20 to 30 VDC
Control output current: 20 mA or less
(GT2-71MCN(P) only) Ambient temperature: -10 to 45°C 14 to 113°F
[When 9 to 15 units are connected including the main unit]
Power supply voltage: 20 to 30 VDC
Control output current: 10 mA or less (including the DL-RB1A output current)
Residual voltage: 1.5 V or lower
(GT2-71MCN(P) only) Ambient temperature: -10 to 45 °C 14 to 113 °F
*2 The GT2-71MCN(P) does not have HH/LL.