Specifications
Model |
AP-41M |
|||
Application |
Gauge pressure |
|||
Type |
Negative pressure |
|||
Rated pressure |
0 to -101.3 kPa |
|||
Fluid type |
Air, non-corrosive gasses |
|||
Temperature characteristics |
±2 % of F.S. (When the temperature varies from 25 °C 77 °F) |
|||
Pressure port |
M3 male threaded |
|||
Environmental resistance |
Pressure resistance |
500 kPa |
||
Ambient temperature |
0 to +50 °C 32 to 122 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 4 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
1,000 m/s2, 10 times in each of X, Y and Z directions, total of 60 times |
|||
Material |
Case: PBT, Screw: SUS303, Cable: PVC |
|||
Weight |
Approx. 68 g (including cable) |
|||


Specifications
Model |
EM-014A*1 |
|||
Type |
Shielded |
|||
Shape |
M14 Threaded |
|||
Detecting distance |
4.0 mm 0.16" ±10% |
|||
Detectable object |
Ferrous metals (see Characteristics for non-ferrous metals) |
|||
Standard target |
15 x 15 mm 0.59" x 0.59" |
|||
Hysteresis |
10% max. of detecting distance |
|||
Response frequency |
1.2 kHz |
|||
Operation mode |
N.O. |
|||
Temperature characteristics |
±10% max. of detecting distance at +23°C 73.4°F, within -10 to +70°C 14 to 158°F |
|||
Display indicator |
Red LED |
|||
Control output |
NPN: 200 mA (40 V) max., Residual voltage: 1 V max. |
|||
Housing |
Cr-plated brass |
|||
Rating |
Power voltage |
10.8 to 30 VDC, Ripple (P-P) 10 % or less*2 |
||
Current consumption |
12 mA or less |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Ambient temperature |
-25 to +80 °C -13 to 176 °F (No freezing) |
|||
Relative humidity |
35 to 95 % RH (No condensation) |
|||
Weight |
Approx. 60 g (including nuts and 2-m 6.6' cable) |
|||
*1 The alternate-frequency type of EM-014 | ||||

Specifications
Model |
GL-VCC5 |
|||
Type |
Extension cable |
|||
Number included |
1 pc. |
|||
Cable end |
Female side: M12 connector 5 pin |
|||
Number of cores |
5 |
|||
Length |
5 m 16.4' |
|||
Material |
connector: PVC/Nickel-plated brass |
|||
Weight |
300 g |
|||

Specifications
Model |
ER-N12 |
|||
Type |
Separate amplifier Amplifier unit Expansion unit (cable type) |
|||
No. of control outputs |
2 |
|||
No. of external inputs |
1 |
|||
Temperature characteristics |
±8% or less of detecting distance at +25°C +77°F (-25 to +55°C -13°F to +131°F) *1 |
|||
Response time |
150 μs *2/ 300 μs *2/ 1 ms / 4 ms / 16 ms / 64 ms (switchable) |
|||
Network compatibility |
NU Series |
|||
Function |
Operation mode |
Normal / Magnetic metal / Non-magnetic metal / Hybrid |
||
Timer function |
Timer OFF / Off Delay / On Delay / One Shot / On-Off Delay / On-Delay One Shot |
|||
I/O |
Control output |
Open-collector, 30 VDC or less, PNP/NPN switchable |
||
External input |
Tuning / Detection stop / Zero shift / Hold value reset (switchable) |
|||
Additional expansion units |
Up to 8 units (9 units connected in total including the main unit); Up to 16 units when connecting an ER-N10 to an NU Series device |
|||
Protection circuit |
Protection against reverse power connection, output overcurrent, output surge, and reverse output connection |
|||
No. of mutual interference prevention units |
OFF / 4 units / 8 units (selectable) *3 |
|||
Power supply |
Power voltage |
18 to 30 VDC *4 (including 10% or less ripple (P-P)), Class 2 |
||
Power consumption (excluding load current) |
1110 mW or less (47 mA or less at 24 V, 62 mA or less at 18 V) |
|||
Environmental resistance |
Ambient temperature |
Operation: -25 to +55°C -13°F to +131°F *5, Storage: -30 to 70°C -22°F to +158°F (no freezing) |
||
Relative humidity |
Operation/storage: Up to 85% RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions |
|||
Shock resistance |
500 m/s2 1640.4 ft/s2 (50 G), 10 times in each of the X, Y, and Z directions |
|||
Case material |
Main unit and cover: Polycarbonate, FG terminal: Copper/iron, Sheet metal: Aluminum alloy, M8 connector metal: Nickel-plated brass |
|||
Accessories |
Instruction manual |
|||
Weight |
Approx. 90 g 3.18 oz |
|||
*1 The value when the operation mode is set to “Normal”, using the 2-point adjust function at a distance of 25% of the stable detection range with no detectable object, and a standard detectable object is placed at a distance of 50% of the stable detection range. | ||||

Specifications
Model |
FL-CP160 |
|||
Total length (at 25 °C) |
1613 |
|||
Measurement range (dead zone excluded) |
1,557 (1,537)*1 |
|||
Weight |
Approx. 880 g |
|||
*1 Values for water. For oil | ||||

Specifications
Model |
EH-108 |
|||
Type |
Oil-resistant, Shielded, Threaded*1 |
|||
Detectable object |
Ferrous metals (see Characteristics for nonferrous metals) |
|||
Standard target (iron, t=1 mm 0.04") |
10 x 10 mm 0.39" x 0.39" |
|||
Stable detecting range |
0 to 1.5 mm0.06" |
|||
Maximum detecting distance |
2.5 mm0.10" |
|||
Hysteresis |
0.07 mm0.003" |
|||
Repeatability |
0.005 mm0.0002" |
|||
Temperature characteristics |
±10% max. of detecting distance at 23°C 73.4°F, within -10 to +60°C 14 to 140°F |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Ambient temperature |
-10 to +60 °C 14 to 140 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Weight |
Approx. 51 g (including nuts and 3-m 9.8' cable) |
|||
*1 Not designed for immersed use. | ||||

Specifications
Model |
OP-51464 |
|||
Overview |
Front protective cover protecting detection side of light curtain. |
|||
Applicable product |
SL-V95F, SL-V48H, SL-V24L, SL-C48H, SL-C24L |
|||
Number included |
1 pcs. |
|||
Length |
950.3 mm 37.41" |
|||
Material |
Translucent plastic: Polycarbonate (t=Approx. 1.15mm), Black plastic: ABS |
|||
Note |
To install this product on both the transmitter and receiver, 2 sets are required. Use the dimming filters (sold separately) by attaching them to the front protection cover. When the front protection cover is attached, the L-shaped mounting bracket (OP-42 |
|||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
LV-NH47 |
|||
Type |
Definite-reflective |
|||
FDA (CDRH) Part 1040.10 |
Class 1 |
|||
IEC 60825-1 | ||||
Light source |
Visible semiconductor laser, Wavelength: 660 nm |
|||
Detecting |
MEGA |
55 to 85 mm 2.17" to 3.35" |
||
ULTRA | ||||
SUPER | ||||
TURBO | ||||
FINE | ||||
HSP | ||||
Environmental resistance |
Ambient temperature |
-10 to +55°C 14°F to 131°F (No freezing) |
||
Relative humidity |
35 to 85% RH (No condensation) |
|||
Material |
Case |
Glass-reinforced plastic |
||
Lens cover |
Transmitter: Glass |
|||
Weight |
Approx. 70 g 2.47 oz |
|||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
SV2-D20B |
|||
Type |
Motor power cable, Standard cable with electromagnetic brake |
|||
Length |
20 m 65.6' |
|||
Note |
for 200 W / 400 W motor |
|||


Specifications
Model |
NR-EN16 *1 |
|||
Connection target devices |
DL-EN1 (Connected sensor: GT2 Series, GT Series, IL Series, IG Series, IB Series, IX Series, SK Series)*2 |
|||
Connection target device identification |
Automatic identification or manual identification by specifying the IP address |
|||
Communication protocols |
Ethernet TCP/UDP communication, BOOTP/DHCP client supported (compatible with the above connection target devices) |
|||
Interface |
Ethernet 100Base-TX (AUTO-MDI/MDIX-compatible), 1 port*3 |
|||
Number of channels |
16 ch max. (varies depending on connected devices) |
|||
Collection period |
Maximum sampling cycle: 1 ms (1 kHz) to 60 s |
|||
Buffer memory |
8M data*5 |
|||
Sensor power output function |
• Output from power supply output connector (4-pole terminal block) (switchable between output ON and OFF) |
|||
Power consumption |
1.6 W or less*6 |
|||
Surrounding air temperature |
0 to +40°C 32°F to 104°F |
|||
Operating ambient humidity |
10 to 85% RH (no condensation) |
|||
Weight |
Approx. 150 g 5.30 oz (including approx. 10 g 0.35 oz for the OP-88513 (NR-EN16 power supply terminal block)) |
|||
*1 For NR-EN16 units, connect the Ethernet cable directly to the target device. Operation with hubs is not guaranteed. | ||||


Specifications
Model |
KV-N16ER |
|||
Expansion output unit |
Output Points |
16 points |
||
External connectionmethod |
Relay |
|||
External connection method |
Terminal block |
|||
Rated load |
250 VAC/30 VDC, 2 A |
|||
Leakage current (when output is OFF) |
− |
|||
Residual voltage (at ON) | ||||
ON resistance |
50 mΩ or less |
|||
Common method |
4 points/1 common |
|||
Response time |
OFF to ON |
10 ms or less |
||
ON to OFF | ||||
Relay life |
Electrical: 100000 cycles or more (20 cycles/minute) |
|||
Relay replacement |
Impossible |
|||
Internal current consumption |
100 mA or less |
|||
Weight |
Approx. 260 g |
|||
*1 The KV-N16ER has two terminals for each of C0, C1, C2, and C3 respectively, which are shorted internally. (C0, C1, C2, and C3 are independent.) | ||||

Specifications
Model |
FD-XS8 |
|||
Supported pipe materials |
Metal pipes, Plastic pipes (soft/hard) *1 |
|||
Supported fluids |
Liquids (water, oil, adhesive, grease, chemical solutions, etc.) *1 |
|||
Supported fluid temperature |
0 °C (no freezing on the pipe surface) to 100 °C 32 to 212 °F (Pipe surface temperature) |
|||
Clamp set model |
Plastic pipe/tube attachment |
FD-XC8R1, FD-XC8R2, FD-XC8R3 |
||
Metal pipe attachment |
FD-XC8M*2 |
|||
Maximum rated flow rate |
Outer diameter of pipe ø 6 0.24 ", 1/4 " (6.35 mm) : 0 to 3000 mL/min |
|||
Zero cut flow rate |
40 mL/min*3 (variable, default) |
|||
Display resolution |
Instantaneous flow rate |
0.1/1/10 mL/min (Displayed on controller) |
||
Shot amount |
0.001/0.01/0.1/1 mL (Displayed on controller) |
|||
Repeatability |
Plastic pipe/tube attachment |
Response time: 50 ms |
F.S. |
± 0.1 %*4*5 |
Instantaneous flow rate |
Outer diameter of pipe ø 6 0.24 ", 1/4 " (6.35 mm) : ±3 mL/min |
|||
Response time: 500 ms |
Outer diameter of pipe ø 6 0.24 ", 1/4 " (6.35 mm) : ±1.0 mL/min |
|||
Metal pipe attachment |
Response time: 50 ms |
F.S. |
Outer diameter of pipe ø 6 0.24 ", 1/4 " (6.35 mm) : ±0.3 % |
|
Instantaneous flow rate |
Outer diameter of pipe ø 6 0.24 ", 1/4 " (6.35 mm) : ±9 mL/min |
|||
Response time: 500 ms |
Outer diameter of pipe ø 6 0.24 ", 1/4 " (6.35 mm) : ±2.9 mL/min |
|||
Hysteresis |
Variable |
|||
Integrated unit display |
0.1/1/10/100/1000/10000 mL (displayed on controller) |
|||
Display method |
Status indicator |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) , IP68G (JIS C0920) *6 |
||
Ambient temperature |
-10 to 60 °C (No freezing) 14 to 140 °F |
|||
Relative humidity |
35 % to 85 %RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, double amplitude 1.5 mm 0.06 ", 2 hours each for X,Y,Z direction |
|||
Shock resistance |
50 G 11 ms 3 times each for X,Y,Z direction |
|||
Material |
Sensor head |
Head body: PPS/PPSU, in-cable amplifier: PPS, cable: PVC, controller connector: PPS/PBT/POM |
||
Clamp set |
For plastic pipe |
Body, fixing screw: PPS, detection surface: special rubber, pipe support rubber: FKM, sensor head fixing screw: SUSXM7 |
||
For metal pipe |
Metal: SUS304/SUSXM7, detection surface: special rubber, clamp support rubber: FKM, sensor head fixing screw: SUSXM7 |
|||
Weight |
Approx. 250 g |
|||
*1 Liquid must allow for the passage of an ultrasonic pulse, as well as not contain large air pockets or excessive bubbles. Readings may become unstable depending on the type of pipe. | ||||

Specifications
Model |
SJ-H228C |
|||
Type |
HC |
|||
Ion generation method |
Corona discharge |
|||
Structure |
Shock-proof, resistance-coupled |
|||
Voltage application method/applied voltage |
Pulse AC method/±7000 V |
|||
Ion balance control method |
Dual I.C.C. method |
|||
Ion balance |
±30 V *1 |
|||
Cleanliness |
ISO 14644-1 Class 2 *2 |
|||
Operating distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
NPN open collector or non-voltage contact signal |
|||
Control output |
NPN type photorelay, 100 mA max. (at 40 V max.) |
|||
Major functions |
Condition alarm output, ion level alarm output, alarm output |
|||
Air purge connection port |
Rc 1/8 |
|||
Air purge supplied pressure |
0.5 MPa or less *3 |
|||
Effective length |
2280 mm 89.76" *4 |
|||
No. ofelectrodes |
36 |
|||
Static elimination bar length |
2240 mm 88.19" |
|||
Rating |
Power voltage |
24 VDC-36 V±10% |
||
Current consumption |
500 mA (at 24 VDC)/350 mA (at 36 VDC) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32.0°F to 104.0°F |
||
Relative humidity |
35 to 85% RH (No condensation) |
|||
Material |
Electrode probe |
Silicon |
||
Main unit |
ABS resin/PC |
|||
Weight |
Static elimination bar |
2350 g 82.89 oz |
||
*1 Value measured under the following conditions: | ||||

Specifications
Model |
CV-L35 |
|||
Focal point |
35 mm 1.38" |
|||
F-stop range (aperture) |
F1.6 to F16 |
|||
Minimum WD |
0.3 m 1.0' |
|||
Mount |
C-mount |
|||
Filter size |
30.5 mm 1.20" P0.5 |
|||
Compatible image sensor size |
2/3" |
|||
TV distortion |
-0.2 % (-0.08 %)*1 |
|||
Resolving power |
100 cycles/mm at center, 40 cycles/mm on periphery |
|||
Ambient temperature/humidity range |
0 to +50 °C 32 to 122°F, 35 to 80 % RH (No condensation) |
|||
Polarizing filter |
OP-54030 |
|||
Protective filter |
CA-LF30 |
|||
Weight |
Approx. 85 g |
|||
*1 Indicates specification for compatible image sensor size. Value in parenthesis applies to 1/3" image sensor size. | ||||



PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
CA-LH50G |
|||
Type |
Vibration-resistant models |
|||
Compatible image sensor size |
2/3" |
|||
Focal point |
50 mm 1.97" |
|||
F-stop range (aperture) |
F2.8/4/8/16*1 |
|||
Minimum WD |
0.2 m 0.7'*2 |
|||
Resolving power |
100 cycles/mm (center), 80 cycles/mm (periphery) |
|||
Filter size |
27.0 mm 1.06" P0.5 |
|||
TV distortion |
-0.03 % (-0.01 %)*3 |
|||
Mount |
C-mount |
|||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F |
||
Relative humidity |
35 to 80 % RH (No condensation) |
|||
Weight |
Approx. 76 g |
|||
*1 The vibration-resistant types are designed to have their apertures replaced. When shipped, the OPEN aperture is attached to the lens, so replace this with one of the other included apertures (F4, F8, or F16) as necessary. To use the f-stop (aperture) in the OPEN mode, use the lens without removing the OPEN aperture. | ||||