Specifications
Model |
OP-88022*1 |
|||
Type |
Small mounting bracket |
|||
Applicable product |
LR-W70/WF10 |
|||
Material |
SUS304 |
|||
Note |
M3 screw × 2 supplied |
|||
Weight |
Approx. 50 g |
|||
*1 The 4-pin M12 connector type may not be mounted in the orientation shown in the picture (connector downward). Confirm the dimensions and surroundings carefully. | ||||

Specifications
Model |
SZ-VPC03*1 |
|||
Type |
Quick Disconnect |
|||
Cable end |
M12 |
|||
Length |
0.3 m 0.98' |
|||
Weight |
Approx. 80 g |
|||
*1 SZ-VPC03 is equipped with only 4 pins: 24 V, 0 V, OSSD1, OSSD2. | ||||

Specifications
Model |
BT-CG64 |
|||
Dedicated AC adaptor specifications (OP-88389) |
Input |
100 to 240 VAC 50/60 Hz 70 VA |
||
Output |
12 VDC 5.0 A maximum (60 W max.) |
|||
Average active efficiency |
89% or more |
|||
Efficiency at low load (10%) |
87% or more |
|||
No-load power consumption |
0.04 W |
|||
Dimensions |
110 x 62.0 x 31.5 mm (excluding the cable) |
|||
Weight |
Approx. 150 g (excluding the AC cable) |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C (No freezing) |
||
Relative humidity |
~ 85%RH (No condensation) |
|||
Storage temperature |
-20 to +60°C (No freezing) |
|||
Storage relative humidity |
~ 85%RH (No condensation |
|||
Dimensions |
181 x 130 x 59 mm |
|||
Weight |
Approx. 340 g |
|||

Specifications
Model |
IX-1050 |
|||
Main unit / expansion unit |
Expansion unit |
|||
Display |
Min. display unit |
10 µm*1 |
||
Display range |
±999.99 to ±999 mm (with 4 selectable steps)*1 |
|||
Tools |
Scan mode |
Height, Height difference, Max./Min., Height difference calculation, Thickness calculation, Height detection, Monochromatic detection, Position adjustment |
||
Line mode |
Height (Ave./Max./Min.) , Height difference (Ave./Max./Min.) , Height difference calculation, Thickness calculation, Position adjustment, Tilt correction |
|||
Other functions |
Common |
ZERO/offset, Operating threshold adjustment, 2-point calibration, Measurement direction, Position correction NG measurement, |
||
Scan mode |
Measurement range, Measurement position (small/standard/large) , Measurement mode, Measurement noise elimination, |
|||
Line mode |
Average count, Laser position adjustment, Timing input, Head tilt correction (fixed only), Ambient light removal for measurement, HOLD function, Alarm setting, Measurement method (Ave./Max./Min.) |
|||
Input |
Input |
Non-voltage input/voltage input is switchable |
||
Number of inputs |
8 (IN1 to IN8) |
|||
Function |
IN1: External trigger up/down timing, IN2 to IN8: Enable by assigning optional functions |
|||
Output |
Output |
Open collector output; NPN/PNP switchable, N.O./N.C. switchable |
||
Number of inputs |
10 (OUT1 to OUT10) |
|||
Function |
Enable by assigning the optional functions |
|||
Analog voltage output |
Not available |
|||
Analog current output | ||||
Number of programs |
32 |
|||
Statistical information |
Scan mode: Measured value / Degree of similarity (Max., Min., Ave.), Processing time (Latest, Max., Min., Ave.), Count (Number of OKs / Number of NGs / Number of triggers) |
|||
Detection record |
Number of storage |
Scan mode |
80 images (FTP/SFTP Client function: Enable) |
|
Line mode |
400 images (FTP/SFTP Client function: Enable) |
|||
Detection history |
Save conditions |
NG only/All is selectable*4 |
||
FTP/SFTP data transfer (FTP/SFTP client function) |
Transfer Destination |
FTP/SFTP server |
||
Transfer format |
bmp/jpeg/txt is selectable |
|||
Transfer Condition |
4 conditions |
|||
Ethernet |
Standard |
Not available |
||
Connector | ||||
Interface compatibility |
CC-Link / DeviceNet® / EtherNet/IP™ / EtherCATⓇ / RS-232C / BCD / PROFINET / PROFIBUS / TCP/IP output*5 |
|||
Number of connectible units |
Main units: 1, Expansion units: 1, Communication units (DL) : 1 |
|||
Ratings |
Power voltage |
Supplied from main unit |
||
Current consumption |
Max. 1.9 A or less (With main unit only: 0.8 A or less, With unit expansion: 1.9 A or less) (Excluding output load)*6 |
|||
Environmental resistance |
Ambient temperature |
0 to +50°C 32 to 122°F (No freezing) |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Material |
Main unit case: PC/Power connector: PA, POM/Analog output connector: PA, POM/I/O connector: PA/ |
|||
Weight |
Approx. 190 g |
|||
*1 For displaying on an IX Series control panel or PC software. | ||||


Specifications
Model |
FR-SH01C |
|||
Type |
Short range Compact chemical model |
|||
Measuring range |
Up to 1.5 m 4.9'*1 |
|||
Display range |
Up to 2 m 6.6'*1 |
|||
Measurable dielectric constant of medium |
2 or higher*2 |
|||
Resolution |
1 mm 0.04" |
|||
Precision |
Up to 0.1 m 0.3': ±20 mm 0.79"; |
|||
Response time |
0.4 s, 1.5 s, 4 s (default value), 10 s |
|||
Tank pressure |
-0.1 to +0.1 Mpa |
|||
Material |
Tank interior |
Lens: PTFE |
||
Housing |
PPS PPSU |
|||
Connection diameter |
G3/4 (20 A) |
|||
Output |
No. of control outputs |
─ |
||
Control output/auxiliary output | ||||
Analog output | ||||
External input | ||||
Network compatibility | ||||
Analog output accuracy |
Resolution |
|||
Zero accuracy | ||||
F.S. accuracy | ||||
Power supply |
Power voltage |
|||
Power consumption | ||||
Environmental resistance |
Ambient temperature |
–10 to +70°C*4 14°F to 158°F |
||
Relative humidity |
Up to 85% RH (no condensation) |
|||
Temperature of coupling used |
–10 to +85°C 14°F to 185°F (no freezing)*4 |
|||
Vibration resistance |
10–500 Hz Power spectral density: 0.816 G2; X, Y and Z directions |
|||
Shock resistance |
100 m/s2 (10 G), 16 ms pulses, 1000 times each for X, Y and Z directions |
|||
Enclosure rating |
IP67 (IEC60529) |
|||
Protection circuit |
Protection against reverse power connection, power supply surges, output overcurrent protection, and output surges |
|||
Weight |
Approx. 140 g 4.94 oz |
|||
*1 Guaranteed value in water with the recommended installation. Static water can be measured up to the edge of the lens. An undetectable area on the short-range side is created due to the environment and measurement medium. The maximum measuring distance is also shortened. | ||||

Specifications
Model |
IV-G15 |
|||
Type |
Expansion unit |
|||
Tools |
Type |
Shape Detection, Color Area*1, Area*2, position adjustment |
||
Number |
Detection tools: 16 tools, position adjustment tool: 1 tool*3 |
|||
Switch settings (programs) |
32 programs |
|||
Image history |
Numbers |
When using a color type head: 100 images*4, when using a monochrome type head: 300 images*5*6 |
||
Condition |
NG only/All is selectable*6 |
|||
Analysis information |
OFF/Statistics/Histograms is switchable |
|||
Other functions |
HDR, HighGain, Color filters*1, Digital zoom (2x, 4x)*8, Brightness correction, Tilt correction, White balance*1, Mask outline, Mask area, Test run, ToolAutoTune, Input monitor, |
|||
Indicators |
PWR/ERR, OUT, TRIG, STATUS, LINK/ACT |
|||
Input |
Type |
Non-voltage input/voltage input is switchable |
||
Inputs |
6 inputs (IN1 to IN6) |
|||
Function |
IN1: External trigger, IN2 to IN6: Enable by assigning the optional functions |
|||
Output |
Type |
Open collector output NPN/PNP is switchable, N.O./N.C. is switchable |
||
Outputs |
8 outputs (OUT1 to OUT8) |
|||
Function |
Enable by assigning the optional functions |
|||
Ethernet |
Standard |
100BASE-TX/10BASE-T*9 |
||
Connector |
RJ-45 8pin connector*9 |
|||
Network function |
FTP client, EtherNet/IP™, PROFINET |
|||
Rating |
Power voltage |
Supplied from main unit |
||
Current consumption |
0.8 A or less. 1.5 A or less when also using an expansion unit (IV-G15). (The output load is excluded.) |
|||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F (No freezing)*10 |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Material |
Main unit case: Polycarbonate |
|||
Weight |
Approx. 150 g |
|||
*1 Color type only | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
FI-T15 |
|||
Supported pipe diameter |
3/8", 1/2" |
|||
Supported pipe materials |
Metal piping |
|||
Supported temperature range |
−20 to +180°C –4 to +356°F*1 |
|||
Display method |
Organic EL, status indicator light |
|||
Display resolution |
0.1°C 32.18°F |
|||
Response time |
5 s (50% response), 15 s (90% response)*2 |
|||
Display amplifier averaging time |
0.1 s / 10.0 s / 20.0 s / 30.0 s / 60.0 s / 120.0 s / 300.0 s |
|||
Measurement accuracy |
±0.5°C ±0.9°F (pipe temperature −20 to +80°C –4 to 176°F) (ambient temperature of 25°C 77°F)*2*3 |
|||
Hysteresis |
Variable |
|||
Measurement principle |
Pt100 4-wire type |
|||
Power I/O connector |
M8 4-pin connector |
|||
Power supply |
Current consumption |
20 mA or less (excluding load current)*4 |
||
When used standalone |
I/O (switchable) |
Output (Ch1/Ch2) |
Control output: switching NPN/PNP setting |
|
Analog output (Ch2) |
4–20 mA / 0–20 mA (switchable), load resistance 260 Ω or less*5 |
|||
Power voltage |
20–30 VDC, ripple (P-P) 10% included; Class2/LPS*5 |
|||
Protection circuit |
Protection against reverse power connection, power supply surges, output short circuits, and output surges*5 |
|||
Network compatibility |
IO-Link*6*5 |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Ambient temperature |
–10 to +60°C -14 to +140°F (no freezing) |
|||
Relative humidity |
35–85% RH (no condensation) |
|||
Vibration resistance |
10–500 Hz; power spectral density: 0.816 G2/Hz; X, Y and Z directions |
|||
Shock resistance |
100 m/s2 (approx. 10 G), 16 ms pulses, 1000 times each for X, Y and Z directions |
|||
Material |
Display amplifier |
PBT / PAR / POM / SUS303 |
||
Sensor head |
Head: PPS / SUS303 / Sn; Pipe clamp unit: SUS304; Cable: fluororesin |
|||
Display amplifier mounting bracket |
SUS304 |
|||
Weight |
Approx. 80 g 2.82 oz |
|||
*1 When pipe temperature is 100°C 212°F or more, the display amplifier cannot be mounted on the pipe clamp unit. Install the amplifier so it is insulated from the heat from the pipe. | ||||

Specifications
Model |
SV3-B020AS *1 |
|||
General specifications |
Applicable servo amplifier |
SV3-020L2 |
||
Rated output |
200 W |
|||
Rated torque |
0.637 N·m *2 |
|||
Instant maximum torque |
2.23 N·m |
|||
Rated current |
1.6 Arms |
|||
Instant maximum current |
5.8 Arms |
|||
Rated rotation speed |
3,000 min-1 |
|||
High rotation speed |
7,000 min-1 |
|||
Torque constant |
0.444 N·m/Arms |
|||
Rotor moment of inertia |
0.327 ×10-4 kg·m2 |
|||
Rated power rating |
12.4 kW/s |
|||
Rated angle acceleration |
19,400 rad/s2 |
|||
Excitation method |
Permanent magnet |
|||
Position/speed detection encoder |
Resolution |
26 bit |
||
Type |
Absolute (ABS) type |
|||
Operating environment |
Enclosure rating |
Completely closed, self-cooling, IP67 standard (excluding connector and axis through-hole) |
||
Operating ambient temperature |
0 to +60°C 32 to 140°F (reduced ratings at +40°C 104°F or higher) |
|||
Storage ambient temperature |
-20 to +60°C -4 to +140°F |
|||
Operating/storage ambient temperature |
20% to 80% RH (No condensation) |
|||
Operating atmosphere |
Indoors (No corrosive gas, flammable gas, oil mist, or dust) |
|||
Altitude |
2,000 m 6,561.7' or less (reduced ratings at 1,000 m 3,280.8' or more) |
|||
Vibration rank |
V15 |
|||
Vibration resistance |
49 m/s2 160.8 ft/s2 with servo motor flange surface as reference |
|||
Impact resistance |
490 m/s2 1,607.6 ft/s2 with servo motor flange surface as reference, 2 times |
|||
Isolation rank |
UL: Class A, CE: Class B |
|||
Min. insulation resistance |
500 VDC 10 MΩ or more with insulation resistance meter |
|||
Isolation voltage tolerance |
1,500 VAC for 1 minute |
|||
Approved standards |
UL/CSA standards |
UL1004-1, UL1004-6, CSA C22.2 No.100 |
||
CE marking |
Low-voltage directive |
EN60034-1, EN60034-5 |
||
EMI |
EN55011 Class A, EN61800-3, EN61000-6-4 |
|||
EMS |
EN61800-3, EN61000-6-2 |
|||
North America EMI standard |
FCC Part 15 B, ICES-003. Class A |
|||
Allowable load inertia moment |
15×*3 |
|||
Approx. weight |
1.4 kg 3.09 lb |
|||
Electromagnetic brake specifications |
Capacity |
6 W |
||
Rated voltage |
24 VDC ±10% |
|||
Rated current (@20°C 68°F) |
0.25 A |
|||
Holding torque |
0.637 N·m |
|||
Release time |
60 ms |
|||
Operating time |
100 ms |
|||
*1 The open and operation times of the electromagnetic brake depend on the discharge circuit. | ||||

Specifications
Model |
FU-R6F*1 |
|||
Type |
Threaded and Hex-Shaped Active Receiver Fibers |
|||
Size |
M6 |
|||
Fibre unit length |
2 m6.6'Free-cut |
|||
Fibre unit diameter |
ø 2.2ø 0.09" x 2 |
|||
Shape |
Threaded |
|||
Minimum bend radius |
R25 mmR0.98" |
|||
Environmental resistance |
Ambient temperature |
−40 to +60 ˚C -40 to +140 °F |
||
Weight |
Approx. 21 g |
|||
*1 For details on the detecting distance, see the fiber amplifier catalog. | ||||


Specifications
Model |
CA-DQR10M |
|||
Type |
Square Lights (Multi-Angle) |
|||
LED color |
red |
|||
Power consumption |
11.7 W |
|||
Weight |
Approx 250 g |
|||



Specifications
Model |
ER-M05NC |
|||
Type |
Compact all-metal shielded type Screw type M5 Connector (M8 3-pin) NPN output |
|||
Power supply cable length |
― *1 |
|||
No. of control outputs |
1 |
|||
Output mode |
N.O. |
|||
Button |
None |
|||
Button |
Function |
― |
||
Detecting distance |
1.5 mm 0.06" ±10% *2 |
|||
Response frequency |
170 Hz *3 *4 |
|||
Hysteresis distance |
15% or less of detecting distance |
|||
Detectable object |
Magnetic metal, Non-magnetic metal *5 |
|||
Standard detectable object (Iron, t = 1 mm 0.04") |
5 × 5 mm 0.20" × 0.20" |
|||
Temperature characteristics |
±10% or less of detecting distance at +25°C +77°F |
|||
Control output |
Open-collector, 30 VDC or less, Max. 50 mA |
|||
Control output |
Residual voltage |
NPN output: 0.9 V or less (Output current: 10 mA or less) / 1.4 V or less (Output current: 10 to 50 mA) *6 |
||
Power supply |
Power voltage |
16 to 30 VDC (including 10% or less ripple (P-P)), Class 2 |
||
Power consumption (excluding load current) |
960 mW or less (40 mA or less at 24 V, 60 mA or less at 16 V) |
|||
Protection circuit |
Protection against reverse power connections, output short-circuits, and reverse output connections |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529) |
||
Ambient temperature |
-25 to +70°C -13°F to +158°F (no freezing) |
|||
Relative humidity |
Up to 95% RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions |
|||
Shock resistance |
500 m/s2 1640.4 ft/s2 (50 G), 10 times in each of the X, Y, and Z directions |
|||
Material |
Head |
SUS316L |
||
Amplifier |
Header-to-amplifier cable: TPU, Case: PBT/TPU |
|||
Accessories |
Nut: SUS303 |
|||
Accessories |
Nut × 2 |
|||
Weight |
Approx. 25 g |
|||
*1 Ensure the power cable is no longer than 30 m 98.4' for connector types and no longer than 20 m 65.6' with IO-Link connections. | ||||

Specifications
Model |
EV-118UC |
|||
Type |
DC , Non-shielded |
|||
Shape |
M18 |
|||
Detecting distance |
15 mm 0.59" ±10% |
|||
Detectable object |
Ferrous metals (see Characteristics for nonferrous metals) |
|||
Standard target |
50 x 50 mm 1.97" |
|||
Hysteresis |
20% max. of detecting distance, within -10 to +70°C 14 to 158°F |
|||
Response frequency |
350 Hz |
|||
Operation mode |
N.C. |
|||
Temperature characteristics |
±10% max. of detecting distance, |
|||
Control output |
5 to 200 mA |
|||
Protection circuit |
Reversed polarity, short-circuit, surge voltage |
|||
Rating |
Power voltage |
12 to 24 VDC, Ripple (P-P) 20 % or less |
||
Current consumption (leakage |
Current consumption (leakage current): 1.0 mA max., Residual voltage: 3.6 V max. (with 2-m 6.6' cable) |
|||
Residual voltage |
Residual voltage: 3.6 V max. (with 2-m 6.6' cable) |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Ambient temperature |
-25 to +80 °C -13 to 176 °F (No freezing) |
|||
Relative humidity |
35 to 95 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
1,000 m/s2, 3 times in each of the X, Y, and Z directions |
|||
Case material |
Nickel-plated brass |
|||
Accessories |
Nut × 2, toothed washer × 1, instruction manual |
|||
Weight |
Approx. 140 g |
|||

Specifications
Model |
CA-LH50 |
|||
Focal point |
50 mm 1.97" |
|||
F-stop range (aperture) |
F2.8 to F22 |
|||
Minimum WD |
0.2 m 0.7' |
|||
Mount |
C-mount |
|||
Filter size |
27.0 mm 1.06" P0.5 |
|||
Compatible image sensor size |
2/3" |
|||
TV distortion |
-0.03 % (-0.01 %)*1 |
|||
Resolving power |
100 cycles/mm at center, 80 cycles/mm on periphery |
|||
Ambient temperature/humidity range |
0 to +50°C 32 to 122°F, 80% RH or less (No condensation) |
|||
Weight |
Approx. 92 g |
|||
*1 Indicates specification for compatible image sensor size. Value in parenthesis applies to 1/3" image sensor size. | ||||

Specifications
Model |
EM-080 |
|||
Type |
Shielded |
|||
Shape |
8 mm 0.31" dia Cylindrical. |
|||
Detecting distance |
2.0 mm 0.08" ±10% |
|||
Detectable object |
Ferrous metals (see Characteristics for non-ferrous metals) |
|||
Standard target |
10 x 10 mm 0.39" x 0.39" |
|||
Hysteresis |
10% max. of detecting distance |
|||
Response frequency |
1.2 kHz |
|||
Operation mode |
N.O. |
|||
Temperature characteristics |
±10% max. of detecting distance at +23°C 73.4°F, within -10 to +70°C 14 to 158°F |
|||
Display indicator |
Red LED |
|||
Output |
NPN |
|||
Control output |
NPN: 200 mA (40 V) max., Residual voltage: 1 V max. |
|||
Housing |
Stainless steel |
|||
Rating |
Power voltage |
10.8 to 30 VDC, Ripple (P-P) 10 % or less*1 |
||
Current consumption |
12 mA or less |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Ambient temperature |
-25 to +80 °C -13 to 176 °F (No freezing) |
|||
Relative humidity |
35 to 95 % RH (No condensation) |
|||
Weight |
Approx. 42 g (including nuts and 2-m 6.6' cable) |
|||
*1 Make sure that the power voltage stays within 10.8 V to 30 V even if it is affected by ripple effects. | ||||

Specifications
Model |
AP-32ZP |
|||
Type |
Positive-pressure Type, PNP |
|||
Rated pressure |
0 to 100.0 kPa |
|||
Fluid type |
Air or non-corrosive gases |
|||
Type of pressure |
Gauge pressure, air or non-corrosive gases |
|||
Display |
3 1/2-digit, 2-color, 7-segment LED (Character height: 11 mm 0.43"), Display cycle: 5 times/s |
|||
Display resolution |
0.1 kPa (0.001 bar) |
|||
Detectable pressure range |
-15 to +110 % of F.S. |
|||
Hysteresis |
Variable (when hysteresis mode is selected), 0.5 % of F.S. in standard mode |
|||
Response time (Chattering prevention function) |
2.5/5/100/500 ms (selectable) |
|||
I/O |
Zero-shift input |
Input time: 20 ms or more |
||
Control output |
PNP open-collector 100 mA max. (30 V max.), Residual voltage: 1 V max. 2-output (N.O./N.C.selectable) |
|||
Rating |
Power voltage |
12 to 24 VDC ±10 % |
||
Current consumption |
50 mA (at 24 V) or less, 90 mA (at 12 V) or less |
|||
Environmental resistance |
Pressure resistance |
5.0 bar (500 kPa) |
||
Ambient temperature |
0 to +50 °C 32 to 122 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Material |
Front housing: Polyamide, Front panel sheet: PET, Rear housing: Polysulfone,Pressure port: Die-cast zinc, Cable: Oil-proof cabtyre cable |
|||
Accessories |
Mounting bracket A, mounting bracket B, hexagon socket head cap plug |
|||
Weight |
Approx. 120 g |
|||

Specifications
Model |
FS-MC8P |
|||
Output |
PNP |
|||
Response time |
Depends on the response time settings of the connected expansion units |
|||
External input |
Input time of the connected expansion units +11 ms |
|||
Number of inputs and outputs |
Separate control outputs: 8, common output: 1, common input: 1 |
|||
Unit expansion |
Up to 8 expansion units can be connected. (However, each dual output type will be treated as 2 expansion units.) Allowable passing current: 1200 mA or less |
|||
Indicators |
STATUS indicator (green and red two-color display) MEMORY indicator (orange) LOCK indicator (orange) |
|||
Separate control output, |
PNP open-collector, 30 V or less, 20 mA or less per output, residual voltage: 1.6 V or less |
|||
Protection circuit |
Protection against reverse power connection, reverse output connection, output overcurrent, and output surge |
|||
Power supply |
Power voltage |
10 to 30 VDC (including 10 % ripple (P-P) or less) , class 2 or LPS*1 |
||
Power consumption |
690 mW or less (when used as a solitary unit) (26 mA or less at 24 V/38 mA or less at 12 V [excluding the load current] )*2 |
|||
Environmental resistance |
Ambient temperature |
-20 °C -4 °F to +55 °C +131 °F (no freezing) |
||
Vibration resistance |
10 to 55 Hz; double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axes |
|||
Shock resistance |
500 m/s2; 3 times each for X, Y, and Z axes |
|||
Case material |
Main unit and cover: polycarbonate |
|||
Weight |
Approx. 110 g |
|||
*1 Match the rated power supply voltage of the expansion units to be connected to the system. | ||||


PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.