Specifications
Model |
GL-R64H |
|||
Detection capability |
ø0.98" ø25 mm |
|||
Total length |
50.39" 1280mm |
|||
No. of beam |
64 |
|||
Detection height |
49.61" 1260mm |
|||
Protection height |
51.38" 1305mm |
|||
Beam axis spacing/Lens diameter |
20 mm / ø5 0.79" / ø0.20" |
|||
Detecting distance |
0.66 to 49.21' 0.2 to 15 m*1 |
|||
Effective aperture angle |
Max. ±2.5° (When operating distance is 9.84' 3 m or more) |
|||
Light source |
Infrared LED (870 nm) |
|||
Response time (OSSD) (ms) |
Wire synchronization, One-line or |
ON→OFF |
11.3 |
|
OFF→ON |
55.8*2 |
|||
All blocked→ON |
82.1*3 |
|||
Optical synchronization system |
ON→OFF |
16.4 |
||
OFF→ON |
63.4*2 |
|||
All blocked→ON |
102.5*3 |
|||
Detection mode |
Turns on when no interruptions are present in the detection zone |
|||
Synchronization between the transmitter and receiver |
Optical synchronization or Wire synchronization (Determined by wiring) |
|||
Light interference prevention function |
Prevents mutual interference in up to two GL-R systems. |
|||
Control output |
Output |
2 transistor outputs. (PNP or NPN is determined by the cable type) |
||
Max. load current |
500 mA*4 |
|||
Residual voltage (during ON) |
Max. 2.5 V (with a cable length of 16.40' 5 m) |
|||
OFF state voltage |
Max. 2.0 V (with a cable length of 16.40' 5 m) |
|||
Leakage current |
Max. 200 µA |
|||
Max. capacitive load |
2.2 µF |
|||
Load wiring resistance |
Max. 2.5 Ω |
|||
Supplemental output |
AUX |
transistor outputs. (PNP or NPN is determined by the cable type) |
||
Error output | ||||
Muting lamp output |
Incandescent lamp (24 VDC, 1 to 5.5 W) |
|||
External input |
When using a PNP output cable |
EDM input |
ON voltage: 10 to 30 V |
|
When using an NPN output cable |
ON voltage: 0 to 3 V |
|||
Power supply |
Power voltage |
24 VDC ±20%, ripple (P-P) 10% or less, Class 2 |
||
Current |
Transmitter |
73 |
||
Receiver |
83 |
|||
Protection circuit |
Reverse current protection, short-circuit protection for each output, surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC61496-1, EN61496-1, UL61496-1 |
|
EMI |
EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA |
|||
Safety |
IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Overvoltage category |
II |
|||
Ambient light |
Incandescent lamp: 3,000 lux or less., Sunlight: 20,000 lux or less |
|||
Operating ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) |
|||
Operating relative humidity |
15 to 85 % RH (No condensation) |
|||
Storage temperature |
-25 to +60 °C -13 to 140 °F (No freezing) |
|||
Storage relative humidity |
15 to 95 % RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions |
|||
Shock resistance |
100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions |
|||
Material |
Main unit case |
Aluminum |
||
Upper case/lower case |
Nylon (GF 30%) |
|||
Front cover |
Polycarbonate, SUS304 |
|||
Weight |
Transmitter |
1780 g |
||
Receiver |
1790 g |
|||
*1 When the option front protection cover is installed on the one of transmitter or receiver, the Operating distance is shorten by 1.64' 0.5 m. When the front covers are installed on both of the transmitter and receiver, the Operating distance is shorten by 3.28' 1.0 m. | ||||

Specifications
Model |
OP-87337 |
|||
Overview |
Specialised stand for securing the macro lens to the equipment. |
|||
Applicable product |
CA-LM0210, CA-LML0210 |
|||
Weight |
Approx. 980 g |
|||

Specifications
Model |
KV-CA1W |
|||
General specifications |
Vibration resistance |
10 to 500 Hz; Power spectral density: |
||
Operating ambient temperature |
0 to +50°C 32 to 122°F (No freezing) |
|||
Operating ambient humidity |
35 to 85% RH (No condensation) |
|||
Storage ambient temperature |
−20 to +60°C -4 to +140°F (No freezing) |
|||
Storage relative humidity |
35 to 85% RH (No condensation) |
|||
Enclosure rating |
IP65F*1*2 |
|||
Pollution degree |
3 |
|||
Performance specifications |
Installation distance |
100 mm 3.94" to ∞ |
||
Focal distance |
1.05 mm 0.04" (fixed) |
|||
Field of view |
Horizontal field of view: Approx. 180° |
|||
Image-receiving element |
1/2.9-inch color CMOS |
|||
Resolution |
1280 (H) × 960 (V) |
|||
Frame rate |
10/30 fps |
|||
Internal current consumption |
70 mA or less *3 |
|||
Weight |
Approx. 140 g 4.94 oz |
|||
*1 The enclosure rating is evaluated with the camera cable connected. | ||||

Specifications
Model |
FD-ECH8 |
|||
Pipe size |
Outer diameter of pipe |
ø8 0.31" |
||
Installable range |
8.0 0.31" |
|||
Pipe materials |
Polyurethane, nylon, PFA,*1 other*2 |
|||
Supported gases |
Air, nitrogen, argon, and other gases*3 |
|||
Supported gas temperature |
−10°C to +60°C 14 to 140°F |
|||
Operating pressure range |
0 to 0.75 MPa (upper limit depends on pipe specifications) |
|||
Flow rate detection principle |
Ultrasonic transmission time difference method |
|||
Rated flow rate |
(volume flow rate) |
70 L/min 2.47 CFM * Initial display |
||
(20°C 68°F, atmospheric pressure conversion) |
Gas at 20°C 68°F, 0.2 MPa |
210 L/min |
||
Gas at 20°C 68°F, 0.4 MPa |
350 L/min |
|||
Gas at 20°C 68°F, 0.6 MPa |
490 L/min |
|||
Repeatability |
Response time 250 ms: ±2.5% of F.S.*4*5 |
|||
Display resolution |
Instantaneous flow |
0.01/0.1/1 L/min |
||
Accumulated flow |
0.01/0.1/1/10/100 L |
|||
Display method |
Output indicator |
|||
Environmental resistance |
Enclosure rating |
IP65 (IEC60529) |
||
Ambient temperature |
−10°C to +60°C 14 to 140°F (no freezing) |
|||
Relative humidity |
35%RH to 85%RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz, power spectral concentration: 0.816 G2/Hz, XYZ axes |
|||
Shock resistance |
100 m/s2, 16 ms pulse, XYZ axes, 1000 times for each axis |
|||
Material |
Sensor unit |
PBT/PAR/iron |
||
Sensor surface |
Special rubber |
|||
Weight |
Approx. 105 g |
|||
*1 Use PFA tubes in an environment with a temperature of 40°C 104°F or less. | ||||


Specifications
Model |
FD-GD150U |
|||
Pipe size/Outer diameter |
6" (150 A) ø163 to ø171 mm ø6.42" to ø6.73" |
|||
Weight |
Approx. 0.77 kg |
|||


Specifications
Model |
FD-H47F |
|||
Type |
Hose model |
|||
Supported pipe diameter |
ø33–47.9 ø1.299"-1.886" |
|||
Supported pipe materials |
Soft plastic piping, all hoses (braided hoses, pressure-resistant rubber hoses, etc.)*1 |
|||
Supported fluids |
All fluids (water, oil, chemicals, etc.)*1 |
|||
Supported fluid temperature |
0–100°C 32–212°F (no freezing on pipe surface)*2 |
|||
Maximum rated flow |
300 L/min |
|||
Zero cut flow rate |
2.0 L/min |
|||
Detection principle |
Delta TOF |
|||
Function for automatic correction for speed of sound in liquid |
— |
|||
Display |
QVGA 2.0 model: color LCD, status indicator light |
|||
Display update cycle |
Approx. 10 times/second |
|||
Display resolution |
Instantaneous flow |
0.01/0.1/1 (L/min) (default value: 1) |
||
Integrated flow |
0.01/0.1/1 (L) (default value: 1; up to 8 digits) |
|||
Response time |
0.5 s / 1.0 s / 2.5 s / 5.0 s / 10.0 s / 30.0 s / 60.0 s / 120.0 s / 200.0 s |
|||
Measurement accuracy |
— |
|||
Repeatability |
0.5 s: ±1.0%, 1 s: ±0.7%, 2.5 s: ±0.45%, 5 s: ±0.3%, 10 s: ±0.2%, 30 s: ±0.15%, 60 s: ±0.1% of F.S.*3*4 |
|||
Hysteresis |
Variable |
|||
Flow units |
L/min m3/h G/min |
|||
Pulse output increments (L) |
0.02–999.99 |
|||
Pipe temperature measurement accuracy |
— |
|||
Network support |
IO-Link*5 |
|||
Heat calculation function |
Unit |
MJ/h kW kBTU/h*6 |
||
Display resolution |
Instantaneous value (MJ/h): 0.01/0.1/1 (default value 0.1); Integrated value (MJ): 0.01/0.1/1 (default value 0.1)*6 |
|||
Pulse output increments (MJ) |
0.02–999.99*6 |
|||
Data accumulation |
Accumulation period |
Approx. 1 year |
||
Data reading |
USB2.0 |
|||
Power I/O connector |
M12 8-pin connector (male) |
|||
I/O (switchable) |
Output (Ch1/2/3/4) |
Instantaneous flow mode / area mode / pulse output mode / integrated flow mode / bubble detection mode / error output |
||
Analog output (Ch1/2) |
4–20 mA/0–20 mA (switchable), load resistance 500 Ω or less |
|||
External input (Ch2/3) |
Integrated reset input / flow-rate zero input / zero-point adjustment input / bank input |
|||
Power supply |
Power voltage |
20–30 VDC, ripple (P-P) 10% included, Class 2/LPS |
||
Current consumption |
240 mA or less (when using flow sensor standalone; with analog output; excluding load current)*7 |
|||
Protection circuit |
Protection against reverse power connection, power supply surges, output short circuits, and output surges |
|||
Environmental resistance |
Enclosure rating |
IP65/67 (IEC 60529)*8 |
||
Ambient temperature |
Sensor head: −20 to +60°C –4 to +140°F (no freezing); Display unit: −20 to +50°C –4 to +122°F (no freezing)*2 |
|||
Relative humidity |
35–85% RH (no condensation) |
|||
Vibration resistance |
10–500 Hz; Power spectral density: 0.816 G2/Hz; X, Y and Z directions |
|||
Shock resistance |
100 m/s2 (approx. 10 G), 16 ms pulses, 1000 times each for X, Y and Z axes |
|||
Material |
Display unit |
Body: PPS/PET/POM; Display window: PAR |
||
Sensor head |
Body: PPS/PET/PAR/SUS304; Cable: PVC |
|||
Weight |
approx. 1130 g 39.86 oz |
|||
*1 For fluids through which ultrasonic waves propagate, and which do not contain a large quantity of bubbles. Detection may be unstable depending on the type and condition of the pipe. | ||||

Specifications
Model |
CA-DBW34H |
|||
Type |
High-Intensity, Large Bar Light |
|||
LED color |
White |
|||
Diffusion plate |
A diffusion plate is included with the CA-DBWxxH. The thickness of the diffusion plate is approximately 2 mm 0.08". |
|||
Power consumption |
18.4 W × 2 ch*1*2 |
|||
Input voltage |
12 VDC |
|||
Polarizing diffusion plate |
OP-87977*3 |
|||
Weight |
Approx. 1,050 g |
|||
*1 Connect these models to both channels. | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.


Specifications
Model |
OP-88900 |
|||
Female |
M12 8pin L-shape |
|||
Male |
Strand wire |
|||
Length |
2 m 6.6' |
|||
Material |
cable: Chemicalresistant PVC |
|||


PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
FL-P20 |
|||
Probe length |
200*1 |
|||
Measurement range (dead zone excluded) |
165 (120)*2 |
|||
Weight |
Approx. 75 g |
|||
*1 Total length including the projected areas of the sensor refer to External Dimension Diagrams for details. Can be shortened up to 100 mm 3.93". | ||||

Specifications
Model |
BT-GN6 |
|||
Type |
Gun Grip Attachment |
|||
Weight |
Approx. 600 g 21.18 oz |
|||


Specifications
Model |
GL-VB32 |
|||
Number included |
2 |
|||
Material |
SUS304, NBR |
|||
Weight |
160 g 5.64 oz *1 |
|||
*1 GL-V Mounting includes two mounting brackets. The weight stated is for both items. | ||||

Specifications
Model |
CA-DZW45D*1 |
|||
Type |
Diffuse Line Lights |
|||
LED color |
White |
|||
Power consumption |
19.8 W × 2 ch*2 |
|||
Input voltage |
12 VDC |
|||
Weight |
620 g |
|||
*1 The diffusion plate is integrated into the light and is not removable. | ||||

Specifications
Model |
FR-LEXB43 |
|||
Type |
Zener barrier with explosion-proof box |
|||
Input/Output |
2-wire system |
|||
Explosion-Proof Specifications |
AEx db [ia Ga] |
|||

Specifications
Model |
OP-84338 |
|||
Overview |
Connection connector to a display unit. Needed when cutting the cable. |
|||
Applicable product |
GT2 |
|||
Number included |
2 pcs. |
|||
Note |
Adjustable cable diameter: 1.15 to 1.35mm (Cable external diameter) |
|||

Specifications
Model |
CA-DRM5X |
|||
Type |
Multi-Spectrum Lighting |
|||
Illumination method |
Ring illumination (with support for optional CA-DRM (DA) Series dome attachment and CA-DRM (PA) Series polarization attachment*1) |
|||
Response speed |
1 ms or less |
|||
LED |
Peak wavelength |
Ultraviolet: 405 nm / Blue: 457 nm / Green: 527 nm / Orange: 600 nm / Red: 660 nm |
||
Controller connection |
Dedicated cable (3 m 9.8' / 5 m 16.4' / 10 m 32.8'), Max. 30 m 98.4' (with extension cables*4) |
|||
I/F input |
12-pole connector (dedicated cable) |
|||
Power consumption |
51.4 W (during normal light emission) |
|||
Environmental resistance |
Ambient temperature |
0 to 40 °C 32 to 104 °F |
||
Relative humidity |
65%RH or less (No condensation) |
|||
Weight |
Approx. 560 g (With dome attachment: Approx. 680 g/With polarization attachment: Approx. 690 g) |
|||
*1 The UV and IR wavelengths cannot be used when the polarization attachment is attached. | ||||