Specifications
Model |
SJ-H156A |
|||
Type |
HA |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method/applied voltage |
Pulse AC method, ±7000 V |
|||
Ion balance control method |
Dual I.C.C. method |
|||
Ion balance |
±30 V *1 |
|||
Operating distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
NPN open collector or contact point signal without voltage |
|||
Control output |
NPN photo relay, Maximum 100 mA max. (40 V or less) |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air purge connection port |
Rc 1/8 |
|||
Air purge supplied pressure |
0.5 MPa or less *2 |
|||
Effective length |
1560 mm 61.42" *3 |
|||
No. ofelectrodes |
24 |
|||
Static elimination bar length |
1520 mm 59.84" |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
500 mA (at 24 V), 350 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
35 to 85% RH (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main unit |
ABS/PC |
|||
Weight |
Static elimination bar |
1550 g 54.67 oz |
||
*1 Measured under the following conditions. | ||||

Specifications
Model |
DX-RM1GA |
|||
Display |
Charging Confirmation LED |
2-color LED |
||
Operations |
Hard Keys |
Front keys × 27 |
||
RFID |
Supported Tags |
ISO/IEC 18000-6 Type C (EPC Global Class 1 Gen 2) |
||
Frequency Range |
902.75 - 927.25 MHz |
|||
Transmission Output |
500 mW or less |
|||
Power Source |
Type |
Dedicated lithium ion battery pack (DX-BC6) |
||
Capacity |
6270 mAh |
|||
Interfaces |
Magnet Connector |
Supported (charging/communication) |
||
Dimensions |
222.4 × 70.6 × 50 mm |
|||
Weight |
Approx. 205 g 7.24 oz |
|||

Specifications
Model |
KV-CA1H |
|||
General specifications |
Vibration resistance |
10 to 500 Hz; Power spectral density: |
||
Operating ambient temperature |
0 to +50°C 32 to 122°F (No freezing) |
|||
Operating ambient humidity |
35 to 85% RH (No condensation) |
|||
Storage ambient temperature |
−20 to +60°C -4 to +140°F (No freezing) |
|||
Storage relative humidity |
35 to 85% RH (No condensation) |
|||
Enclosure rating |
IP65F*1*2 |
|||
Pollution degree |
3 |
|||
Performance specifications |
Installation distance |
200 mm 7.87" to ∞ |
||
Focal distance |
3.8 mm 0.15" (fixed) |
|||
Field of view |
Horizontal field of view: Approx. 60° |
|||
Image-receiving element |
1/2.9-inch color CMOS |
|||
Resolution |
640 (H) × 480 (V) |
|||
Frame rate |
10/30/120 fps |
|||
Internal current consumption |
70 mA or less *3 |
|||
Weight |
Approx. 90 g 3.18 oz |
|||
*1 The enclosure rating is evaluated with the camera cable connected. | ||||

Specifications
Model |
IV-H1 |
|||
Type |
Software for the IV-H Series |
|||
Operating System |
Windows 10 Home/Pro/Enterprise*1 |
|||
Supported languages |
Japanese/English/German/Simplified Chinese/Traditional Chinese/ |
|||
CPU |
Windows 10/7: needs to be compliant with system requirements for OS |
|||
Memory capacity |
Windows 10/7: needs to be compliant with system requirements for OS |
|||
Available hard disk space |
1 GB or more |
|||
Display |
Resolution 1,024 x 768 pixels or higher, Display Color High Color (16 bit) or higher |
|||
PC interface |
Equip the Ethernet (100BASE-TX) interface |
|||
Note |
.NET Framework 4.0 or 4.5 needs to be installed*2 |
|||
*1 Supported for 32 bit and 64 bit version. | ||||

Specifications
Model |
OP-87637 |
|||
Number included |
1 |
|||
Cable end |
Sensor side: M12 4-pin straight, Cable end: Loose wires |
|||
Length |
10 m 32.81' |
|||
Material |
PUR zinc nickel plating |
|||
Weight |
Approx. 310 g |
|||

Specifications
Model |
LV-H64 |
|||
Type |
Long distance |
|||
FDA (CDRH) Part 1040.10 |
Class II |
|||
Light source |
Visible red semiconductor laser |
|||
Wavelength |
660 nm |
|||
Detecting distance |
FINE |
100 to 500 mm 3.94" to 19.69" (100 to 700 mm 3.94" to 27.56")*1 |
||
TURBO |
200 to 850 mm (300 to 1000 mm) |
|||
SUPER |
400 to 1200 mm (600 to 1500 mm) |
|||
Environmental resistance |
Ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) |
||
Material |
Case |
Reinforced glass/plastic |
||
Lens cover |
Norbornene plastic |
|||
Reflective mirror |
Polycarbonate, acrylic |
|||
Weight |
Approx. 45 g |
|||
*1 The parentheses indicate the detecting distance when OP-51428 is used. | ||||

Specifications
Model |
GL-SA40F |
|||
Type |
Protection cover Flat type for 40 beam axes |
|||
Overview |
This protective case protects the main unit from impacts. |
|||
Applicable product |
GL-S40FH |
|||
Number included |
1 |
|||
Length |
822.6 mm 32.39" |
|||
Material |
aluminum |
|||
Note |
2 each of the following are included: hexagon socket head cap screw (width across flats: 3 mm), washer, and special hexagon socket head cap screw (M4, length: 13 mm, width across flats: 3 mm). |
|||
Weight |
260 g |
|||


Specifications
Model |
FD-MZ10ATK*1 |
|||
Type |
Vertical |
|||
Shape |
Built-in amplifier |
|||
Rated flow range |
0.14 - 2.60 G/min (0.50 - 10 L/min)*1 |
|||
Possible display range |
0.14 - 6.35 G/min (0.50 - 30 L/min)*2 |
|||
Possible ranges to set |
0 - 6.35 G/min (0 - 30 L/min) |
|||
Connection port |
NPT3/8 (10 A) |
|||
Detectable fluids |
Water or non-corrosive liquid |
|||
Conductivity of detection fluids |
5 µS/cm or higher |
|||
Detection fluid temperature |
0 to +85°C 32 to 185 °F (No freezing) |
|||
Pressure loss |
Max. 1.45 PSI (0.01 MPa) |
|||
Display method |
Dual row display with 4-digit, 7 segment LED, bar display (2 colors), output indicators, flow indicator |
|||
Display resolution |
0.01/0.1 (G/min, L/min) selectable |
|||
Repeatability |
0.5 s : ±5% of F.S., 1 s : ±3.5% of F.S., 2.5 s : ±2.5% of F.S., 5 s : ±1.6% of F.S., 10 s : ±1% of F.S., 30 s : ±0.8% of F.S., 60 s : ±0.6% of F.S.*3 |
|||
Hysteresis |
Variable |
|||
Response time (chatter prevention feature) |
0.5 s/1 s/2.5 s/5 s/10 s/30 s/60 s variable |
|||
Accumulated flow unit |
0.01/0.1/1/10/100 (G, L) selectable |
|||
Integration data storage cycle |
Save to memory every 10 seconds |
|||
Memory backup |
EEPROM (Data storage length : 10 years or longer, Data read/write frequency : 1 million times or more) |
|||
Analog output |
4-20 mA, max. load resistance 260 Ω Analog output range can be set to any value |
|||
Integration reset/bank switch input/flow zero function input |
Input time : 20 ms or greater,Select either the accumulation output or the accumulation pulse by setting the mode |
|||
Power consumption (Current consumption) |
Normal : 1700 mW (70 mA), Power save : 1000 mW (40 mA) |
|||
Rating |
Power voltage |
24 VDC, Ripple (P-P) 10 % or less, Class 2 |
||
Environmental resistance |
Enclosure rating |
IP65 |
||
Pressure resistance |
290 PSI (2.0 MPa) |
|||
Applied pressure range |
Max. 145 PSI (1.0 MPa) |
|||
Ambient temperature |
0 to +50 °C 32 to 122 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Material |
Liquid end materials |
Bore : SCS13, Measurement pipe : PPS, O ring : fluoro-rubber (FKM) |
||
Other materials |
Plastic case areas : PPS, Metal case areas : SUS430, Cable : PVC |
|||
Accessory |
Instruction Manual, Connector cable (2.7 m 106.3") |
|||
Weight |
Approx. 865 g |
|||
*1 The rated flow range indicates recommended operating range. | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
OP-87409 |
|||
Type |
Rear Fittings |
|||
Applicable product |
LR-Z Series |
|||
Material |
SUS316L |
|||
Weight |
Approx. 30 g |
|||

Specifications
Model |
SJ-E252A |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 V |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Installation distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector, Maximum 100 mA (40 VDC or less) |
||
Condition alarm output | ||||
Alarm output | ||||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc 1/8 |
|||
Air supply pressure |
0.1 MPa to 0.5 MPa*2 |
|||
Effective length |
2580 mm 101.57"*3 |
|||
Total length |
2480 mm 97.64" |
|||
No. ofelectrodes |
41 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
35 to 85% RH (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
2500 g 88.19oz |
|||
*1 Measured under the following conditions. | ||||

Specifications
Model |
OP-88090 |
|||
Type |
Ethernet extension cable (M12) |
|||
Length |
5 m 16.40' |
|||
Weight |
Approx. 340 g |
|||

Specifications
Model |
ER-GS12P03C |
|||
Type |
General-purpose all-metal shielded type Screw type M12 Connector with pigtail (M12 4-pin) PNP output Short-Range |
|||
Power supply cable length |
0.3 m 1.0' *1 |
|||
No. of control outputs |
2 |
|||
Output mode |
Output 1 |
N.O. |
||
Output 2 |
N.C. |
|||
Button |
None |
|||
Button |
Function |
― |
||
Detecting distance |
2 mm 0.08" ±10% *2 |
|||
Response frequency |
150 Hz *3 *4 |
|||
Hysteresis distance |
15% or less of detecting distance |
|||
Detectable object |
Magnetic metal, Non-magnetic metal *5 |
|||
Standard detectable object (Iron, t = 1 mm 0.04") |
12 × 12 mm 0.47" × 0.47" |
|||
Temperature characteristics |
±10% or less of detecting distance at +25°C +77°F (-25 to +55°C -13°F to +131°F) |
|||
Control output |
Open-collector, 30 VDC or less; 50 mA or less for 1 output; 50 mA or less in total for 2 outputs |
|||
Control output |
Residual voltage |
PNP output: 2.2 V or less (Output current: 10 mA or less) / 2.3 V or less (Output current: 10 to 50 mA) *6 |
||
Power supply |
Power voltage |
16 to 30 VDC (including 10% or less ripple (P-P)), Class 2 |
||
Power consumption (excluding load current) |
1000 mW or less (42 mA or less at 24 V, 63 mA or less at 16 V) |
|||
Protection circuit |
Protection against reverse power connections, output short-circuits, and reverse output connections |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529), IP67G (JIS C 0920) |
||
Ambient temperature |
-25 to +70°C -13°F to +158°F (no freezing) *7 |
|||
Relative humidity |
Up to 95% RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions |
|||
Shock resistance |
1000 m/s2 3280.8 ft/s2 (100 G), |
|||
Material |
Detecting surface: SUS303, Mounting screw: SUS303, Case resin: PBT, Nut: SUS304, Toothed lock washer: SUS304 |
|||
Accessories |
Nut ×2, Toothed lock washer ×1 |
|||
Weight |
Approx. 50 g 1.77 oz |
|||
*1 Ensure the power cable is no longer than 30 m 98.4' for connector and connector with pigtail types. | ||||


Specifications
Model |
CA-DDB15 |
|||
Type |
Dome Light |
|||
LED color |
Blue |
|||
Power consumption |
18.8 W |
|||
Input voltage |
12 VDC |
|||
Weight |
Approx. 170 g |
|||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
OP-89245 |
|||
Type |
This is a 2.5S ferrule mounting bracket with a leakage port on the side. |
|||
Material |
Ferrule mounting bracket: SUS316L |
|||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
OP-88393*1 |
|||
Type |
Separate system |
|||
Length |
30 m 98.43' |
|||
Material |
PVC |
|||
Weight |
Approx. 1200 g |
|||
*1 The unit connection cable for a vertical integrated system is included with the flow meter. | ||||

Specifications
Model |
AP-10SK |
|||
Type |
Compound Sensor Head |
|||
Rated pressure |
-29.9 to 29.9 inchHg |
|||
Fluid type |
Gases and liquids compatible with 304 and 630 stainless steel |
|||
Type of pressure |
Gauge pressure |
|||
Repeatability |
0.5 % of F.S. max. |
|||
Connection port |
1/8 NPT |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Pressure resistance |
72.5 PSI |
|||
Ambient temperature |
-10 to 70°C(14 to 158°F), No condensation |
|||
Relative humidity |
35 to 85%, No condensation |
|||
Vibration resistance |
10 to 55 Hz, 1.5 mm 0.06" double amplitude in X, Y, and Z directions, 3 hours respectively |
|||
Shock resistance |
500 m/s2 in X, Y, and Z directions 10 times respectively (60 times in total) |
|||
Material |
Diaphragm pressure port: TYPE S17400 stainless steel, Pressure port: 304 stainless steel, Throttle: 304 stainless steel (AP-14SK/15SK/16SK only) |
|||
Accessories |
Sensor head connector: 1 |
|||
Weight |
Approx. 120 g |
|||