Specifications
Model |
SV3-B150AS *1 |
|||
General specifications |
Applicable servo amplifier |
SV3-150L2 |
||
Rated output |
1.3k W |
|||
Rated torque |
8.34 N·m *2 |
|||
Instant maximum torque |
23.3 N·m |
|||
Rated current |
10.7 Arms |
|||
Instant maximum current |
28 Arms |
|||
Rated rotation speed |
1,500 min-1 |
|||
High rotation speed |
4,000 min-1 |
|||
Torque constant |
0.891 N·m/Arms |
|||
Rotor moment of inertia |
22.0 ×10-4 kg·m2 |
|||
Rated power rating |
31.6 kW/s |
|||
Rated angle acceleration |
3,790 rad/s2 |
|||
Excitation method |
Permanent magnet |
|||
Position/speed detection encoder |
Resolution |
26 bit |
||
Type |
Absolute (ABS) type |
|||
Operating environment |
Enclosure rating |
Completely closed, self-cooling, IP67 standard (excluding connector and axis through-hole) |
||
Operating ambient temperature |
0 to +60°C 32 to 140°F (reduced ratings at +40°C 104°F or higher) |
|||
Storage ambient temperature |
-20 to +60°C -4 to +140°F |
|||
Operating/storage ambient temperature |
20% to 80% RH (No condensation) |
|||
Operating atmosphere |
Indoors (No corrosive gas, flammable gas, oil mist, or dust) |
|||
Altitude |
2,000 m 6,561.7' or less (reduced ratings at 1,000 m 3,280.8' or more) |
|||
Vibration rank |
V15 |
|||
Vibration resistance |
49 m/s2 160.8 ft/s2 with servo motor flange surface as reference (up/down, left/right) |
|||
Impact resistance |
490 m/s2 1,607.6 ft/s2 with servo motor flange surface as reference, 2 times |
|||
Isolation rank |
Class F |
|||
Min. insulation resistance |
500 VDC 10 MΩ or more with insulation resistance meter |
|||
Isolation voltage tolerance |
1,500 VAC for 1 minute |
|||
Approved standards |
UL/CSA standards |
UL1004-1, UL1004-6, CSA C22.2 No.100 |
||
CE marking |
Low-voltage directive |
EN60034-1, EN60034-5 |
||
EMI |
EN55011 Class A, EN61800-3, EN61000-6-4 |
|||
EMS |
EN61800-3, EN61000-6-2 |
|||
North America EMI standard |
FCC Part 15 B, ICES-003. Class A |
|||
Allowable load inertia moment |
5×*3 |
|||
Approx. weight |
9.0 kg 19.84 lb |
|||
Electromagnetic brake specifications |
Capacity |
10 W |
||
Rated voltage |
24 VDC (−0%/+10%) |
|||
Rated current (@20°C 68°F) |
0.41 A |
|||
Holding torque |
19.6 N·m |
|||
Release time |
100 ms |
|||
Operating time |
80 ms |
|||
*1 The open and operation times of the electromagnetic brake depend on the discharge circuit. | ||||

Specifications
Model |
GL-RPC03N |
|||
Type |
Main Unit Connection Cable, for Extension |
|||
Number included |
1 cable |
|||
Cable end |
Main unit plug (Grey) - M12 connector (5-pin male) |
|||
Length |
0.3 m 0.98' |
|||
Material |
Main unit connection connector: PBT, Connector for extension: PVC/nickel-plated brass, Cable: PVC |
|||
Note |
Use this together with the extension cable. |
|||
Weight |
Approx. 25 g |
|||

Specifications
Model |
LV-H41 |
|||
Type |
Long-distance area |
|||
FDA (CDRH) Part 1040.10 |
Class I |
|||
Light source |
Invisible infrared semiconductor laser |
|||
Wavelength |
785 nm |
|||
Detecting distance |
FINE |
250 mm 9.84" |
||
TURBO |
500 mm 19.69" |
|||
SUPER |
1000 mm 39.37" |
|||
Environmental resistance |
Ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) |
||
Material |
Case |
Glass reinforced plastic |
||
Lens cover |
Polyarylate |
|||
Weight |
Approx. 45 g |
|||

Specifications
Model |
OP-88296 |
|||
Type |
Loose wires/M12 adapter |
|||
Applicable product |
FD-XA1/XA5 cables, or cables with cross sectional area 0.14 to 0.34 mm2 |
|||
Frequency of connections between conductors of the same cross section |
10 |
|||
Insertion/withdrawal cycles |
More than 100 times |
|||
Wire diameter including insulation |
ø 0.7 to 1.6 mm 0.028 " to 0.06 " |
|||
enclosure rating |
IP65/67 |
|||
Ambient temperature |
-25 °C to +80 °C -13 to 176 °F |
|||
Note |
A connector that converts loose wires to a M12 4-pin connector. Useful for connecting to IO-Link compatible master units. |
|||
Weight |
Approx. 12 g 0.42 oz |
|||

Specifications
Model |
CA-LH12P |
|||
Focal point |
12 mm 0.47" |
|||
F-stop range (aperture) |
F1.4/4/8/16*1 |
|||
Minimum WD |
0.15 m 0.5' |
|||
Filter size |
27.0 mm 1.06" P0.5 |
|||
Mount |
C-mount |
|||
Max. compatible image sensor size |
2/3" |
|||
Resolving power |
100 cycles/mm at center, 80 cycles/mm on periphery |
|||
TV distortion |
-0.07% |
|||
Enclosure rating |
IP64 (objective lens, water repellent coating specifications)*3 |
|||
Ambient temperature/humidity range |
0 to +50°C 32 to 122°F, 80% RH or less (No condensation) |
|||
Weight |
Approx. 75 g |
|||
*1 The f-stop (aperture) is changed by replacing the diaphragm plate. When this product is shipped, the OPEN diaphragm plate is attached to the lens, so replace it with one of the other included diaphragm plates (F4, F8, or F16) as necessary. To use the f-stop (aperture) in the OPEN mode, use the lens without removing the OPEN aperture. | ||||

Specifications
Model |
CA-DP5R |
|||
Type |
Specialised extension cable for LED spot lighting |
|||
Applicable product |
CA-DPR2, CA-DPW2, CA-DPB2 |
|||
Length |
5 m 16.40' |
|||

Specifications
Model |
IV4-G400CA |
|||
Type |
Long range, narrow field of view model |
|||
Installed distance |
From 400 mm 15.75" |
|||
Field of view |
Installation distance of 400 mm 15.75": 58 (H) × 44 (V) mm to |
|||
Image receiving element |
Type |
1/2.9 inch color CMOS |
||
Number of pixels |
1280 (H) × 960 (V) |
|||
Focus adjustment |
Auto *1 |
|||
Exposure time |
12 μs to 9 ms *2 |
|||
Lights |
Illumination |
White LED |
||
Lighting method |
Switchable between pulse and continuous lighting |
|||
Indicators |
2 indicators (both displaying same content) |
|||
Power supply |
Average power consumption |
2.5 W (without AI imaging illumination unit installed) |
||
Environmental resistance |
Enclosure rating |
IP67 *3 |
||
Ambient temperature |
0 to +50°C 32 to +122°F (no freezing) *4 |
|||
Relative humidity |
85% RH or less (no condensation) |
|||
Vibration resistance |
Frequency: 10 to 500 Hz; |
|||
Shock resistance |
500 m/s2 1640.4 ft/s2 3 times in each of 6 directions |
|||
Material |
Main unit case: Zinc die-casting. Front cover: Acrylic. Operation indicator cover: TPU *5 |
|||
Weight |
Approx. 75 g 2.65 oz (no AI imaging illumination unit) |
|||
*1 Focus position can be automatically adjusted during installation. It cannot be adjusted while running. Focus position can be registered separately for each program. | ||||

Specifications
Model |
CV-H100M |
|||
Type |
Camera*1 |
|||
Image element |
2/3-inch monochrome CCD image receiving element, 7 x high-speed reading using square-pixel, 1,040,000 pixels Unit cell size 7.4 x 7.4 µm |
|||
Valid pixel count |
1000000 pixels 1000 (H) × 1000 (V) |
|||
Pixel transfer frequency |
80 MHz 40 MHz × 2ch |
|||
Scanning system |
Progressive (20.5 ms)Interlace (13.9 ms) |
|||
Transfer system |
Digital serial transfer |
|||
Electronic shutter |
1/15, 1/30, 1/60, 1/120, 1/240, 1/500, 1/1000, 1/2000, 1/5000, 1/10000, 1/20000, 0.05 msec to 9000 msec can be set with numeric values. |
|||
Lens mount |
C mount |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Weight |
Approx. 120 g (not including lens) |
|||
*1 Only the high-speed camera cable can be used. | ||||

Specifications
Model |
MP-FR10R |
|||
Type |
Standard model |
|||
Connection bore diameter |
Rc3/8" (10 A) |
|||
Supported gases |
Air and non-corrosive gases |
|||
Supported gas temperature |
-5 to +50°C, 23 to 122°F |
|||
Operating pressure range |
0.2 to 1 MPa, 2 to 10 bar, 29 to 145 psi *1 |
|||
Pressure resistance |
1.5 MPa, 15 bar, 217.5 psi |
|||
Flow rate |
Detection principle |
Heat based (mass flow rate) |
||
Rated flow range (normal) |
2.0 to 1000.0 L/min |
|||
Zero cut flow rate |
2.0 L/min, 0.12 m3/h 4.24 ft3/h, 0.07 CFM |
|||
Measurement accuracy |
±(1.5% of RD + 0.5% of F.S.) *2 *3 |
|||
Repeatability |
±1.0% of F.S. (with an averaging time of 1.0 s) |
|||
Display resolution |
0.1 L/min, 0.01 m3/h 0.35 ft3/h, 0.01 CFM |
|||
Response time |
150 ms (63% response) *4 |
|||
Averaging time |
OFF/100 ms/200 ms/500 ms/1.0 s/3.0 s/5.0 s/10 s/30 s (selectable) |
|||
Pressure (Digital value, gauge pressure) |
Rated pressure range |
0.000 to 1.000 MPa, 0.00 to 10.00bar, 0.0 to 145.0 psi |
||
Measurement accuracy |
±2.0% of F.S. |
|||
Repeatability |
±0.2% of F.S. (with a response time of 50 ms) |
|||
Display resolution |
0.001 MPa, 0.01 bar, 0.1 psi |
|||
Response time |
Selectable from 10 ms, 50 ms, 100 ms, 500 ms, 1.0 s, and 5.0 s *4 |
|||
Humidity (Dew point) |
Rated relative humidity range/ dew point range |
15 to 100%RH (no condensation)/Corresponds to the relative humidity range *5 *6 |
||
Measurement accuracy |
±4°C, ±7°F *5 *6 |
|||
Display resolution |
5%RH/1°C, 1°F *5 *6 |
|||
Temperature |
Measurement accuracy |
±2.0°C, ±3.6°F *7 |
||
Display resolution |
0.1°C, 0.1°F *7 |
|||
Shut-off valve |
Response time |
1 s or less (closed → open) |
||
Leakage amount |
50 mL/min 0.002 CFM (N) or less |
|||
Filter/regulator (Standard model only) |
Pressure adjustment range |
0.15 to 0.90 MPa |
||
Filtration degree |
5 μm 0.196850 Mil |
|||
Drainage cup capacity |
60 cc |
|||
Check valve |
Available |
|||
Display |
Color LCD, status indicator |
|||
Data accumulation |
Accumulation period |
Accumulated data: approx. 2 years/Instantaneous data: approx. 2 weeks |
||
Data reading |
USB 2.0/Ethernet |
|||
I/O |
Control output (Ch.1/2/3/4/5) |
NPN/PNP setting switchable, open collector output 30 VDC or less, N.O./N.C. setting switchable, max. 100 mA/Ch., residual voltage: 2.5 V or less |
||
Analog output (Ch.1/2) |
4 to 20 mA, load resistance: 260 Ω or less *4 |
|||
External input (Ch.2/3/6) |
Short-circuit current: 1.5 mA or less, input time: 20 ms or more |
|||
Protection circuit |
Power supply reverse connection protection, power supply surge protection, reverse connection protection for each I/O, surge protection for each I/O, overcurrent protection for each output |
|||
Power supply |
Power voltage |
24 VDC +25%/-20% (including ripple), Class 2 or LPS |
||
Power consumption |
1.2 A (300 ms) when opening/closing valve, 100 mA at all other times *8 (standalone usage; excluding load current) |
|||
Communication interface |
USB2.0 |
|||
Network compatibility |
When using only this unit: IO-Link (Specification v1.1/COM3) *9 |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529) *10 |
||
Ambient temperature |
−5°C to +50°C 23°F to 122°F (no freezing) *11 |
|||
Relative humidity |
35%RH to 85%RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz; power spectral density: 0.204 G2/Hz; X, Y, and Z directions |
|||
Shock resistance |
300 m/s2, XYZ axes, 10 times for each axis |
|||
Material |
Sensor part : PET/PPS/PBT/POM/aluminum/SPHC |
|||
Weight |
Approx. 1050 g 37.04 oz (excluding drainage cup) |
|||
*1 An upstream side pressure of 0.2 MPa or less (a filter/regulator adjustment pressure of 0.2 MPa or less for the standard model) worsens the flow rate characteristic of the shut-off valve. | ||||


PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
MD-F5120 |
|||
Console (sold separately) |
MC-P1 |
|||
Marking method |
XYZ 3-Axis simultaneous scanning method |
|||
Marking laser |
Type |
Yb: fiber laser, Class 4 laser product (IEC 60825-1, JIS C6802, FDA [CDRH] Part 1040.10*1) |
||
Wavelength |
1090 nm |
|||
Output |
50W |
|||
Pulse frequency |
60 to 120 kHz |
|||
Guide laser/Working distance pointer |
Semiconductor laser, wavelength: 655 nm, output: 1.0 mW, Class 2 laser product (IEC 60825-1, JIS C6802, FDA [CDRH] Part 1040.10*1) |
|||
Marking area |
300 x 300 x 42 mm 11.81" x 11.81" x 1.65" |
|||
Standard working distance (±variable width) |
300 mm (±21 mm) 11.81" (±0.83") |
|||
Marking resolution |
5 µm 0.20 Mil |
|||
Scan speed |
8000 mm 314.96/s max. |
|||
Character type |
Font |
KEYENCE original font (numerical value, alphabet, katakana, hiragana, and kanji)/user font/true type font |
||
Barcode |
CODE39/ITF/2of5/NW7 (CODABAR)/JAN/EAN/UPC/CODE128 |
|||
2D code |
QR code/micro QR code/DataMatrix (ECC200/GS1 DataMatrix) |
|||
GS1 DataBar |
GS1 DataBar Truncated/GS1 DataBar Truncated CC-A/GS1 DataBar Stacked/GS1 DataBar Stacked CC-A/GS1 DataBarLimited/GS1 DataBar Limited CC-A |
|||
Logo image |
Custom font, logo (CAD) data BMP/JPEG/PNG/TIF |
|||
Machinery operation |
Fixed point/straight line/dashed line/oval |
|||
Marking conditions |
Workpiece style |
Stationary marking/movement marking (constant speed/encoder) |
||
Character size (marking height/width) |
0.1 to 300 mm 0.004" to 11.81" |
|||
No. of registered programs |
2000 settings max. |
|||
No. of program blocks |
256 blocks |
|||
I/O (Input/output) |
Terminal block input and output/MIL connector input and output |
|||
Interface |
RS-232C, RS-422A, USB 2.0,*2 Ethernet (100BASE-TX/10BASE-T) |
|||
CF memory card slot |
Compact flash memory card*3 |
|||
Head installation direction |
All directions |
|||
Head cable length |
4 m 13.12' |
|||
Cooling method |
Controller: forced air cooling, head: natural air cooling |
|||
Rated voltage and power consumption |
100 to 120 VAC or 200 to 240 VAC ± 10 %, 50/60 Hz, Max. 750 VA |
|||
Environmental resistance |
Enclosure rating |
IP64 (Head) |
||
Pollution degree |
2 |
|||
Overvoltage category |
II |
|||
Ambient temperature for storage |
-10 to +60 °C 14 to 140 °F (No freezing) |
|||
Ambient temperature |
0 to +40 °C 32 to 104 °F |
|||
Ambient humidity for storage |
30 to 85 % RH (No condensation) |
|||
Relative humidity | ||||
Weight |
Controller: 27.5 kg |
|||
*1 The laser classification is implemented based on IEC 60825-1 in accordance with the requirements of FDA [CDRH] Laser Notice. | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
CA-DZW10X |
|||
Type |
LumiTraxTM (specular reflection mode) line lighting |
|||
LED color |
White |
|||
Controller connection |
Dedicated cable (3 m 9.8', 5 m 16.4', 10 m 32.8') , 30 m 98.4' max. (when using extension cables*1) |
|||
Rating |
Power/current consumption |
27 W (1.3 A) |
||
Weight |
Approx. 800 g |
|||
*1 Up to two extension cables can be connected to the dedicated cable. | ||||

Specifications
Model |
ER-GL08P03C |
|||
Type |
General-purpose all-metal shielded type Screw type M8 Connector with pigtail (M12 4-pin) PNP output Long-Range |
|||
Power supply cable length |
0.3 m 1.0' *1 |
|||
No. of control outputs |
2 |
|||
Output mode |
Output 1 |
N.O. |
||
Output 2 |
N.C. |
|||
Button |
None |
|||
Button |
Function |
― |
||
Detecting distance |
3 mm 0.12" ±10% *2 |
|||
Response frequency |
80 Hz *3 *4 |
|||
Hysteresis distance |
15% or less of detecting distance |
|||
Detectable object |
Magnetic metal, Non-magnetic metal *5 |
|||
Standard detectable object (Iron, t = 1 mm 0.04") |
9 × 9 mm 0.35" × 0.35" |
|||
Temperature characteristics |
±10% or less of detecting distance at +25°C +77°F (-25 to +55°C -13°F to +131°F) |
|||
Control output |
Open-collector, 30 VDC or less; 50 mA or less for 1 output; 50 mA or less in total for 2 outputs |
|||
Control output |
Residual voltage |
PNP output: 2.2 V or less (Output current: 10 mA or less) / 2.3 V or less (Output current: 10 to 50 mA) *6 |
||
Power supply |
Power voltage |
16 to 30 VDC (including 10% or less ripple (P-P)), Class 2 |
||
Power consumption (excluding load current) |
750 mW or less |
|||
Protection circuit |
Protection against reverse power connections, output short-circuits, and reverse output connections |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529), IP67G (JIS C 0920) |
||
Ambient temperature |
-25 to +70°C -13°F to +158°F (no freezing) *7 |
|||
Relative humidity |
Up to 95% RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions |
|||
Shock resistance |
500 m/s2 1640.4 ft/s2 (50 G), |
|||
Material |
Detecting surface: SUS303, Mounting screw: SUS303 (M30: SUS304), Case resin: PBT, Nut: SUS304, Toothed lock washer: SUS304 |
|||
Accessories |
Nut ×2, Toothed lock washer ×1 |
|||
Weight |
Approx. 40 g |
|||
*1 Ensure the power cable is no longer than 30 m 98.4' for connector and connector with pigtail types and no longer than 20 m 65.6' with IO-Link connections. | ||||

Specifications
Model |
OP-88196 |
|||
Type |
M12 power supply cable Outdoor use |
|||
Length |
10 m 393.70' |
|||
Material |
PUR, SUS316L |
|||
Weight |
Approx. 310 g |
|||

Specifications
Model |
GL-R10L |
|||
Detection capability |
ø1.77" ø45 mm |
|||
Total length |
15.75" 400mm |
|||
No. of beam |
10 |
|||
Detection height |
14.17" 360mm |
|||
Protection height |
17.52" 445mm |
|||
Beam axis spacing/Lens diameter |
40 mm / ø5 1.57" / ø0.20" |
|||
Detecting distance |
0.66 to 49.21' 0.2 to 15 m*1 |
|||
Effective aperture angle |
Max. ±2.5° (When operating distance is 9.84' 3 m or more) |
|||
Light source |
Infrared LED (870 nm) |
|||
Response time (OSSD) (ms) |
Wire synchronization, One-line or |
ON→OFF |
6.6 |
|
OFF→ON |
48.7*2 |
|||
All blocked→ON |
63.1*3 |
|||
Optical synchronization system |
ON→OFF |
7 |
||
OFF→ON |
49.3*2 |
|||
All blocked→ON |
64.9*3 |
|||
Detection mode |
Turns on when no interruptions are present in the detection zone |
|||
Synchronization between the transmitter and receiver |
Optical synchronization or Wire synchronization (Determined by wiring) |
|||
Light interference prevention function |
Prevents mutual interference in up to two GL-R systems. |
|||
Control output |
Output |
2 transistor outputs. (PNP or NPN is determined by the cable type) |
||
Max. load current |
500 mA*4 |
|||
Residual voltage (during ON) |
Max. 2.5 V (with a cable length of 16.40' 5 m) |
|||
OFF state voltage |
Max. 2.0 V (with a cable length of 16.40' 5 m) |
|||
Leakage current |
Max. 200 µA |
|||
Max. capacitive load |
2.2 µF |
|||
Load wiring resistance |
Max. 2.5 Ω |
|||
Supplemental output |
AUX |
transistor outputs. (PNP or NPN is determined by the cable type) |
||
Error output | ||||
Muting lamp output |
Incandescent lamp (24 VDC, 1 to 5.5 W) |
|||
External input |
When using a PNP output cable |
EDM input |
ON voltage: 10 to 30 V |
|
When using an NPN output cable |
ON voltage: 0 to 3 V |
|||
Power supply |
Power voltage |
24 VDC ±20%, ripple (P-P) 10% or less, Class 2 |
||
Current |
Transmitter |
43 |
||
Receiver |
69 |
|||
Protection circuit |
Reverse current protection, short-circuit protection for each output, surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC61496-1, EN61496-1, UL61496-1 |
|
EMI |
EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA |
|||
Safety |
IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Overvoltage category |
II |
|||
Ambient light |
Incandescent lamp: 3,000 lux or less., Sunlight: 20,000 lux or less |
|||
Operating ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) |
|||
Operating relative humidity |
15 to 85 % RH (No condensation) |
|||
Storage temperature |
-25 to +60 °C -13 to 140 °F (No freezing) |
|||
Storage relative humidity |
15 to 95 % RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions |
|||
Shock resistance |
100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions |
|||
Material |
Main unit case |
Aluminum |
||
Upper case/lower case |
Nylon (GF 30%) |
|||
Front cover |
Polycarbonate, SUS304 |
|||
Weight |
Transmitter |
550 g |
||
Receiver | ||||
*1 When the option front protection cover is installed on the one of transmitter or receiver, the Operating distance is shorten by 1.64' 0.5 m. When the front covers are installed on both of the transmitter and receiver, the Operating distance is shorten by 3.28' 1.0 m. | ||||



Specifications
Model |
FD-H32F |
|||
Type |
Hose model |
|||
Supported pipe diameter |
ø23–32.9 ø0.91"-1.295" |
|||
Supported pipe materials |
Soft plastic piping, all hoses (braided hoses, pressure-resistant rubber hoses, etc.)*1 |
|||
Supported fluids |
All fluids (water, oil, chemicals, etc.)*1 |
|||
Supported fluid temperature |
0–100°C 32–212°F (no freezing on pipe surface)*2 |
|||
Maximum rated flow |
200 L/min |
|||
Zero cut flow rate |
1.0 L/min |
|||
Detection principle |
Delta TOF |
|||
Function for automatic correction for speed of sound in liquid |
— |
|||
Display |
QVGA 2.0 model: color LCD, status indicator light |
|||
Display update cycle |
Approx. 10 times/second |
|||
Display resolution |
Instantaneous flow |
0.01/0.1/1 (L/min) (default value: 0.1) |
||
Integrated flow |
0.01/0.1/1 (L) (default value: 0.1; up to 8 digits) |
|||
Response time |
0.5 s / 1.0 s / 2.5 s / 5.0 s / 10.0 s / 30.0 s / 60.0 s / 120.0 s / 200.0 s |
|||
Measurement accuracy |
— |
|||
Repeatability |
0.5 s: ±1.0%, 1 s: ±0.7%, 2.5 s: ±0.45%, 5 s: ±0.3%, 10 s: ±0.2%, 30 s: ±0.15%, 60 s: ±0.1% of F.S.*3*4 |
|||
Hysteresis |
Variable |
|||
Flow units |
L/min m3/h G/min |
|||
Pulse output increments (L) |
0.02–999.99 |
|||
Pipe temperature measurement accuracy |
— |
|||
Network support |
IO-Link*5 |
|||
Heat calculation function |
Unit |
MJ/h kW kBTU/h*6 |
||
Display resolution |
Instantaneous value (MJ/h): 0.01/0.1/1 (default value 0.1); Integrated value (MJ): 0.01/0.1/1 (default value 0.1)*6 |
|||
Pulse output increments (MJ) |
0.02–999.99*6 |
|||
Data accumulation |
Accumulation period |
Approx. 1 year |
||
Data reading |
USB2.0 |
|||
Power I/O connector |
M12 8-pin connector (male) |
|||
I/O (switchable) |
Output (Ch1/2/3/4) |
Instantaneous flow mode / area mode / pulse output mode / integrated flow mode / bubble detection mode / error output |
||
Analog output (Ch1/2) |
4–20 mA/0–20 mA (switchable), load resistance 500 Ω or less |
|||
External input (Ch2/3) |
Integrated reset input / flow-rate zero input / zero-point adjustment input / bank input |
|||
Power supply |
Power voltage |
20–30 VDC, ripple (P-P) 10% included, Class 2/LPS |
||
Current consumption |
240 mA or less (when using flow sensor standalone; with analog output; excluding load current)*7 |
|||
Protection circuit |
Protection against reverse power connection, power supply surges, output short circuits, and output surges |
|||
Environmental resistance |
Enclosure rating |
IP65/67 (IEC 60529)*8 |
||
Ambient temperature |
Sensor head: −20 to +60°C –4 to +140°F (no freezing); Display unit: −20 to +50°C –4 to +122°F (no freezing)*2 |
|||
Relative humidity |
35–85% RH (no condensation) |
|||
Vibration resistance |
10–500 Hz; Power spectral density: 0.816 G2/Hz; X, Y and Z directions |
|||
Shock resistance |
100 m/s2 (approx. 10 G), 16 ms pulses, 1000 times each for X, Y and Z axes |
|||
Material |
Display unit |
Body: PPS/PET/POM; Display window: PAR |
||
Sensor head |
Body: PPS/PET/PAR/SUS304; Cable: PVC |
|||
Weight |
approx. 880 g 31.04 oz |
|||
*1 For fluids through which ultrasonic waves propagate, and which do not contain a large quantity of bubbles. Detection may be unstable depending on the type and condition of the pipe. | ||||