Machine Vision Systems

5768 products

Showing 697 - 720 of 5768 products

Showing 697 - 720 of 5768 products
View
keyence Stock Image
Keyence NR-X100W Keyence
Sale price $3,265.99
Only 1 unit left

Specifications

Model

NR-X100W

Main unit buffer memory capacity

50M data*1

Expansion memory

SD card (SD/SDHC)*2

PC interface

USB

USB mini-B connector, USB 2.0 High-speed–compliant, Simultaneous USB connection from one PC to up to four units (switchable by ID switch)

Ethernet

RJ45 connector, 100Base-TX (AUTO MDI/MDIX supported) *3

Wireless LAN

Connection via NR-XW1 wireless LAN unit, IEEE 802.11b/g/n *3

Network function

FTP client function, FTP server function, SNTP client function

Display/operation

Operation via NR-XCP30 control panel, or via WAVE LOGGER X with PC connection

Expansion remote unit connection

Dedicated remote connection connector × 2 (Remote OUT A port, B port)
Unit expansion possible by connecting up to eight NR-XR01 remote units (connected by remote unit cable)

Number of connectable measurement units

Master data collection unit group

Max. 8 units*4

Total with remote units connected

Max. 72 units*5

Continuous acquisition speed

Master data collection unit group

Max. 100 kHz for all acquisition channels *6

Total with remote units connected

Max. 500 kHz for all acquisition channels *6*7

Inter-unit synchronization

Between measurement units in the master data collection unit group

±1 μs or less *8

Between the master data collection unit and each remote unit / environment-resistant measurement unit

Time axis accuracy

±50 ppm (23°C ±3°C 73.4°F ±5.4°F); Same time used for all remote groups, SNTP server time synchronization possible

Synchronous trigger input (SYNC input)

Performance specifications

• Use as external trigger input (normal mode) or synchronous acquisition input (logging mode)
• Non-voltage (contact/non-contact)/voltage input, Falling edge input
• Not insulated from system bus

Input specifications

• For non-voltage input: ON voltage 1.0 V or lower (short circuit current: 1 mA typ.), OFF current 0.1 mA or lower
• For voltage input: ON voltage (Lo) 1.0 V or lower, OFF voltage (Hi) 2.4 V or more, Max. input voltage: 6 V

Control input

Common specifications

• Input type: Bidirectional voltage input
• Maximum rating: 30 VDC, Minimum ON voltage: 10 VDC, Maximum OFF current: 0.2 mA
• Insulation between input and system bus (500 VDC/1 minute)

Individual specifications

• External trigger input (TRG IN): Edge input
• Acquisition start/stop input (START IN): Level input (only enabled in external control mode)
• Auto-balance input (BAL): Edge input (only enabled in external control mode)
• Program selection input 0 to 3 (PROG IN0 to 3): Level input (only enabled in external control mode)

Control output

Common specifications

• Output format: Photo MOS relay output
• Maximum rating: 36 VDC, Output current: 50 mA or less (9-point total: 300 mA or less)
• Leak current at OFF: 0.1 mA or less, Residual voltage when ON: 1 V or less
• Insulation between output and system bus (500 VDC/1 minute)

Individual specifications

• Trigger output (TRG OUT): N.O. output, one-shot output
• System error output (SYS ERR): N.C. output
• Alarm output (ALARM): N.O. output
• Judgment output 1 to 4 (OUT1 to 4): N.O. output
• Ready output (READY): N.O. output

Power supply

• NR-XU1 AC adapter, or 9 to 36 VDC (including ripple) / Max. 72 W (when connected to DC terminal block; at 9 V: 8.0 A or less; at 24 V: 3.0 A or less; at 36 V: 2.0 A or less)
• Battery operation possible when connected to the NR-XU15 Series battery power supply unit

Power supply

Power consumption

8.4 W or less (excluding connected units)

Environmental resistance

Ambient temperature

0 to +40°C 32°F to 104°F

Relative humidity

10 to 85% RH (no condensation)

Weight

Approx. 490 g 17.30 oz (including approx. 10 g 0.35 oz for the OP-88512 (NR-X100W I/O terminal block))

*1 Data is not backed up when the power is turned off. The available data buffer memory per NR-X100W and NR-XR01 group is limited to 25M.
*2 Use only products recommended by KEYENCE (CA-SD4G: 4 GB, CA-SD16G: 16 GB). Using a product not recommended by KEYENCE may result in data not being saved to the SD card during continuous acquisition.
*3 Wired LAN and wireless LAN cannot be used at the same time. When acquiring data from a PC (using WAVE LOGGER X software), use a wired local connection only between the NR-X100W and the PC. Using an onsite local network connection or wireless LAN connection may cause acquisition to stop due to a decrease in transfer speeds caused by network load or wireless LAN communication conditions. The main unit’s automatic saving function allows data to be saved to an SD card in the main unit even if acquisition by PC stops.
*4 Use is permitted only if the total power consumption of all connected measurement units is 20 W or less.
*5 Use is permitted only if the total power consumption of all measurement units, remote units, and environment-resistant measurement units used in the system is 50 W or less when remote units are not connected to an AC adapter.
*6 Acquisition from a PC may not be possible in some PC environments. [Tested conditions] OS: Windows 10 Pro (64 bit), CPU: 3.70 GHz, RAM: 16.0 GB, USB connections: One NR-X100W (no other USB devices), Ethernet connection: One-to-one connection between NR-X100W and PC; Using normal mode and saving in the standard format with a pre-installed OS and running only WAVE LOGGER X. Windows is a registered trademark or a trademark of Microsoft Corporation in the United States and/or other countries.
*7 Each master data collection unit group and remote unit group is limited to 100 kHz for all acquisition channels. When using 5 or more remote units, each remote unit group can have up to 50 kHz per acquisition channel.
*8 The sampling cycle and sampling timing vary depending on the connected measurement unit. When using the NR‑CA04 in combination with other unit types, a sampling delay may occur between the NR-CA04 and the other units with some setting configurations.

keyence Stock Image
Keyence SV-C5F Keyence
Sale price$0.00
Sold Out

Specifications

Model

SV-C5F

Type

Motor power cable, Standard

Length

5 m 16.4'

Note

for 3 kW / 5 kW motor

keyence Stock Image
Keyence OP-83202 Keyence
Sale price$0.00
Sold Out

Specifications

Model

OP-83202

Overview

Front protective cover protecting detection side of light curtain.

Applicable product

SL-V88H, SL-V44L

Number included

1 pcs.

Length

1,750.2 mm 68.91"

Material

Translucent plastic: Polycarbonate Black plastic: ABS

Note

To install this product on both the transmitter and receiver, 2 sets are required. Use the dimming filters (sold separately) by attaching them to the front protection cover. When the front protection cover is attached, the L-shaped mounting bracket (OP-42

keyence Stock Image
Keyence OP-84298 Keyence
Sale price$0.00
Sold Out

Specifications

Model

OP-84298

Type

exchange central supports

Applicable product

SJ-H

keyence Stock Image
Keyence CL-PT010N Keyence
Sale price$0.00
Sold Out

Specifications

Model

CL-PT010N

Type

Optical unit

Head

CL-PT010 *1

Reference distance

10 mm 0.39"

Reference measurement range

Measurement range

±0.3 mm ±0.01"

Linearity

±0.22 μm ±0.000009" *2

High precision measurement range

Measurement range

±0.15 mm ±0.01"

Linearity

±0.2 μm ±0.000008" *2

Resolution

0.25 μm 0.000010" *3

Spot diameter

ø3.5 μm ø0.000138"

Laser class

Optical unit

Class I

Sampling cycle

100/200/500/1000 μs (Adjustable 4-stage)

Environmental resistance

Enclosure rating

Head

IP64 (IEC60529)

Ambient light

Target surface illuminance: 30000 lux (Incandescent lamp)

Operating ambient temperature

Head

0 to 50°C 32 to 122°F

Optical unit

Relative humidity

85% RH or less (no condensation)

Vibration resistance

Head

10 to 57 Hz, double amplitude 0.45 mm 0.02" 2 hours each for X, Y, and Z axes

Optical unit

10 to 57 Hz, double amplitude 0.3 mm 0.01"; 2 hours each for X, Y, and Z axes

Shock resistance

15 G, 6 ms

Vacuum

None

Explosion-proof

performance

Head

Optical unit

Zone/Division

Head

Optical unit

Ambient temperature

Head

Optical unit

Certification number

Temperature characteristic

Head

0.1% of F.S./°C *4

Optical unit

0.015% of F.S./°C

Material

Head

Front: SUS, Rear: Aluminum

Optical unit

Polycarbonate

Weight

Head

Approx. 1100 g 2.43 lb

Optical unit

Approx. 1600 g 3.53 lb

*1 Sensor head and optical unit are a matched pair. Not cross compatible.
*2 Value measured in displacement mode with KEYENCE reference workpiece (mirrored surface).
*3 Value measured using 16,384 average cycles with KEYENCE reference workpiece (mirrored surface).
*4 These figures are based on the case where a jig made of SUS303 (or SUS304) is fixed between the head and the object.

Keyence Stock Image
Keyence SZ-V32NCX Keyence
Sale price $4,970.00
Only 6 units left

Specifications

Model

SZ-V32NCX *1

Type

Network Type (CIP Safety)

Detection capability

Minimum detectable object size

Diameter 20, 30, 40, 50, 70, 150 mm 0.79", 1.18", 1.57", 1.97", 2.76", 5.91" (depends on the setting) Reflectance 1.8% min., Speed 1.6 m/s 5.25 ft/s max. *2

Detectable angle

190° ( -5° to 185° )

Response time (ON to OFF)

Standard Mode

Scan Cycle A

160 ms (2scans) to 1280 ms (16scans) *3 *4

Scan Cycle B

168 ms (2scans) to 1344 ms (16scans) *3 *4

Scan Cycle C

176 ms (2scans) to 1408 ms (16scans) *3 *4

High Speed Mode

Scan Cycle A

80 ms (2scans) to 640 ms (16scans) *3 *4

Scan Cycle B

84 ms (2scans) to 672 ms (16scans) *3 *4

Scan Cycle C

88 ms (2scans) to 704 ms (16scans) *3 *4

Response time (OFF to ON)

Response time (ON to OFF) + 150 ms

Protection zone

Minimum detectable object size: 70 / 150 mm 2.76" / 5.91"

8.4 m 27.56' (Standard Mode) 5.7 m 18.70' (High Speed Mode)

Minimum detectable object size: 50 mm 1.97"

5.6 m 18.37' (Standard Mode) 3.8 m 12.47' (High Speed Mode)

Minimum detectable object size: 40 mm 1.57"

4.3 m 14.11' (Standard Mode) 2.9 m 9.51' (High Speed Mode)

Minimum detectable object size: 30 mm 1.18"

2.9 m 9.51' (Standard Mode) 2.0 m 6.56' (High Speed Mode)

Minimum detectable object size: 20 mm 0.79"

1.6 m 5.25' (Standard Mode) 1.1 m 3.61' (High Speed Mode)

Warning zone

Minimum detectable object size: 70 / 150 mm 2.76" / 5.91"

26 m 85.30' (Standard Mode) 23 m 75.46' (High Speed Mode) *5

Minimum detectable object size: 50 mm 1.97"

25 m 82.02' (Standard Mode) 21 m 68.90' (High Speed Mode) *5

Minimum detectable object size: 40 mm 1.57"

24 m 78.74' (Standard Mode) 20 m 65.62’ (High Speed Mode) *5

Minimum detectable object size: 30 mm 1.18"

23 m 75.46' (Standard Mode) 18 m 59.06' (High Speed Mode) *5

Minimum detectable object size: 20 mm 0.79"

21 m 68.90' (Standard Mode) 15 m 49.21' (High Speed Mode) *5

Additional safety distance

100 mm 3.94" *6

Maximum measurement distance

60 m 196.85' *7

Maximum number of banks

Max.16 banks

Multiple scanner heads

Max. 3 scanner heads

Camera monitoring area

Monitor area: over 190° (-5° to 185°) *8

Display

QVGA 2.2inch color LCD

Light source

Type, wavelength

Infrared laser diode, 905 nm

Laser Class

IEC

Class1 IEC/EN60825-1

FDA

Class1 FDA 21CFR 1040.10, 1040.11 (Laser Notice) *9

JIS

Class1 JIS C6802

Control output (OSSD)

Output

-

Number of outputs

Max. load current

Residual voltage (during ON)

OFF-state voltage

Leakage current

Max. capacitive load

Load wiring resistance

Inputs

PNP

NPN

Non-safety related output (AUX output)

Output type

Number of outputs

Max. load current

Residual voltage (during ON)

Muting lamp

Interface

USB

USB2.0

Ethernet

Standard

IEEE802.3u (100 BASE-TX)

Transmission rate

100 Mbps

Cable

STP(Shielded Twisted Pair)
cable or UTP(Unshielded Twisted Pair) cable. Category5 or higher.

Connector

RJ45 (IP65) 2 ports

Network function

CIP Safety, EtherNet/IP™, UDP

Cable length

Power and I/O cable

30 m 98.43' or less *10

Between scanner head and display unitc

20 m 65.62' or less each *11

Ethernet cable

100 m 328.08' or less *12

Approved standards

EMC

EMS

IEC61496-1, EN61496-1, UL61496-1 (Type 3 ESPE)

EMI

EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA

Safety

IEC61496-1, EN61496-1, UL61496-1 (Type 3 ESPE), IEC61496-3, EN61496-3 (Type 3 AOPDDR), IEC61508, EN61508,
EN ISO13849-1, 2015 (PLd, Category3), UL508, UL1998, CSA C22.2 No.14, CSA C22.2 No.0.8

Rating

Power consumption

13.4 W

Power voltage

24 VDC ±10% (Ripple P-P 10% or less): When using a converter power supply, 24 VDC +20%/-30%: When using a battery

Environmental resistance

Enclosure rating

IP65(IEC60529)

Ambient light

Incandescent lamp: 1500 lux or less *13

Operating ambient temperature

-10 to +50°C 14 to 122°F (No freezing)

Operating relative humidity

35% to 85% RH (No condensation)

Storage temperature

-25 to +60°C -13 to +140°F (No freezing)

Storage relative humidity

35% to 95% RH

Vibration resistance

10 to 55 Hz, 0.7 mm 0.03" compound amplitude, 20 sweeps each in X, Y, and Z directions

Shock resistance

100 m/s2 328.08 ft/s2 (Approx. 10 G) 16 ms pulse, in X, Y, Z directions 1000 times each axis

Material

Scanner head

Main unit case

Magnesium

Window

Polycarbonate, PEI

Indicator part

Aluminum, PES

Display unit

Case

Magnesium, PPS, Polycarbonate

System memory

Aluminum, PPE

Weight

Approx. 2300 g

*1 Integrated models include display unit, scanner head, system memory and a connection cable (SZ-VS005).
*2 If the object to be detected moves parallel to the detection plane, SZ-V cannot detect the object moving at speed over 1.6 m/s 5.25 ft/s, regardless of the encoder setting.
*3 The response time, protection zone, and warning zone are affected by the operation mode.
*4 When using PROFIsafe, 6 ms is added to the response time. When using CIP Safety, 10ms is added to the response time.
*5 20% or more reflectance is necessary for the minimum detectable object in the warning zone.
*6 If there is a highly reflective background within 1.5 m 4.92' from the boundary of the protection zone, 200 mm 7.87" must be added as supplementary necessary distance to the protection zone when calculating the minimum safety distance.
*7 Even when using the network data output, the maximum measured output distance is 60 m 196.85'.
*8 Only applicable for the type with a camera.
*9 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice.
*10 10 m 32.81' or less when supplying power from a battery.
*11 When supplying power from a battery, the length of each connection cable should be 10 m 32.81' or less when using two scanner heads, and 5 m 16.40' or less when using three scanner heads.
*12 Distance between SZ-V and Ethernet switch.
*13 An ambient light source should not be located within ±5° of the detection plane.

keyence Stock Image
Keyence GL-SA20S Keyence
Sale price$0.00
Sold Out

Specifications

Model

GL-SA20S

Type

Protection cover Slim type for 20 beam axes

Overview

This protective case protects the main unit from impacts.

Applicable product

GL-S20SH

Number included

1

Length

422.6 mm 16.64"

Material

aluminum

Note

2 each of the following are included: hexagon socket head cap screw (width across flats: 3 mm), washer, and special hexagon socket head cap screw (M4, length: 13 mm, width across flats: 3 mm).

Weight

140 g

Keyence Stock Image
Keyence SH-302 Keyence
Sale price $546.59
Only 2 units left

Specifications

Model

SH-302*1

Type

Standard Shielded Cylindrical

Shape

ø2.8×12 Cylindrical

Detectable object

Ferrous metal (see Characteristics for nonferrous metals)

Standard target (iron, t=1 mm 0.04")

5 x 5 mm 0.20"*2

Stable detecting range

0 to 0.6 mm 0.02"

Maximum detecting distance

1.6 mm 0.06"

Repeatability

0.001 mm 0.00004"*2

Hysteresis

0.03 mm 0.001"*2

Temperature characteristics

0.3%/°C*2

Environmental resistance

Enclosure rating

IP67

Ambient temperature

-10 to +60 °C 14 to 140 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Weight

Approx. 30 g

*1 The SH-302 cannot be used in combination with the EG-547.
*2 Above values obtained when the detecting distance is set at 50% of the maximum stable detecting distance.

keyence Stock Image
Keyence FU-21 Keyence
Sale price$0.00
Sold Out

Specifications

Model

FU-21

Detecting method

Diffuse Reflective

Size

M3

Detection arrangement

Coaxial

Fibre unit length

50 cm19.685" cannot be cut

Shape

Straight

Minimum bend radius

R25 mm0.984"

Detection distance

7 mm0.276"*1

Environmental resistance

Ambient temperature

-40 to +70 °C -40 to 158 °F

Weight

Approx. 4 g

*1 The detecting distance is a value for white mat paper (the standard detection object) detections.

Keyence New Stock Image
Keyence SC-S11 Keyence
Sale price $902.09
Only 7 units left

Specifications

Model

SC-S11

Response time

25 ms (safety output ON to OFF, IEC/EN60204-1 stop category 0), 70 ms (safety output OFF to ON)

Safety output (S-OUTPUT)

Output

Two PNP outputs

Max. load current

500 mA

Residual voltage (when ON)

2.5 V maximum (with a load current of 500 mA)

Leakage current

1.2 mA maximum

Max. capacitive load

2.2 µF (with a load resistance of 100 Ω)

Load wiring length

30 m maximum

Safety input (S-INPUT, enable input)

Input type

Contact output device connection or PNP output device connection

Short-circuit current

Approx 5mA

ON/OFF voltage

Voltage when product turned on: 19 V or more, voltage when product turned off: 5 V or less

Wiring length

30 m maximum

Safety related input

Input type

Non-voltage contact input (EDM input, reset input)

Short-circuit current

EDM input: Approx. 10 mA, Reset input: Approx. 5 mA (EDM input, reset input)

Wiring length

30 m max. (EDM input, reset input)

Non-safety output

Output

PNP/NPN totem pole output (auxiliary output, lockout output)

Max. load current

50mA (auxiliary output, lockout output)

Load wiring length

10 m maximum (auxiliary output, lockout output)

Non-safety input

Input type

No-voltage contact input or PNP or NPN open-collector input (external off input)

Short-circuit current

Approx 5mA (external off input)

ON/OFF voltage

Voltage when product turned on: 5 V or less or 19 V or more, voltage when product turned off: open or 9 V to 15 V (external off input)

Wiring length

10 m maximum (external off input)

Protection circuit

Power supply reverse polarity protection, overcurrent protection for each output, short-circuit protection , surge protection

Approved standards

EMC

EMS

IEC 61496-1, EN61496-1, UL61496-1

EMI

EN55011 Class A, FCC Part 15 Class A, ICES-003 Issue 4 Class A

Safety

ISO13849-1:2015 (category 4, PLe), UL1998, IEC/EN61496-1, UL508,*1

Rating

Power voltage

24 VDC ±10 %, Ripple (P-P) 10 % or less

Current consumption

1.3 A (at maximum load)

Environmental resistance

Enclosure rating

IP20 (IEC60529)
Must be installed within a control panel rated at IP54 or higher.

Pollution degree

2 (IEC60664/EN50178)

Overvoltage category

2 (IEC60664, EN50178)

Insulation resistance

100 MΩ or more (tested with a 500 VDC megger) between the internal circuit and the external case

Operating ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Operating relative humidity

35 to 85 % RH (No condensation)

Storage temperature

-20 to +65 °C -4 to 149 °F (No freezing)

Storage relative humidity

35 to 85 % RH

Withstand voltage

1,500 VAC, 50/60 Hz for 1 minute between the internal circuit and the external case

Vibration resistance

10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions

Shock resistance

100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Material

Main unit case

Polycarbonate (UL94-V2)

Weight

160 g or less

*1 The following mark is displayed on the ratings indication label on the side of the main unit to identify it as a UL508-certified product.

keyence Stock Image
Keyence KV-NC32ETP Keyence
Sale price $1,110.65
Only 2 units left

Specifications

Model

KV-NC32ETP

Expansion output unit

External connectionmethod

MOSFET (With overcurrent protection function)*1*2

External connection method

Connector

Rated load

30 VDC. 0.2 A *3

Leakage current (when output is OFF)

100 μA or less

Residual voltage (at ON)

0.6 VDC or less

ON resistance

Common method

32 points/1 common (2 terminals)*4*5

Response time

OFF to ON

100 μs or less (with a load of 1 mA or more)

ON to OFF

200 μs or less (with a load of 1 mA or more)

Relay life

Relay replacement

Internal current consumption

50 mA or less

Weight

Approx. 110 g

*1 If even a single overcurrent is detected, the protection operation (output turned OFF) and automatic recovery are repeated for all outputs within the shared common (The outputs within the shared common that are protected when an overcurrent is detected are outputs 000 to 015 or 100 to 115 for the KV-NC32ET(P).) , until the cause of the problem is removed.
*2 MOSFET (N-ch) output for the sink output type; and MOSFET (P-ch) output for the source output type.
*3 The rated load per common terminal is 1.6 A for the KV-NC16ET(P) or KV-NC32ET(P) and 3.2 A for the KV-NC16ET(P)E.
*4 The COM terminals of the KV-NC16ET(P), KV-NC16ET(P)E and KV-NC32ET(P) are shorted internally.
*5 The outputs within the shared common that are protected when an overcurrent is detected are outputs 000 to 015 or 100 to 115 for the KV-NC32ET(P).

Keyence New Stock Image
Keyence SJ-F2000 Keyence
Sale price $10,799.99
Only 5 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence Stock Image
Keyence GL-R44HG Keyence
Sale price $4,490.54
Only 3 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Keyence New Stock Image
Keyence LV-11SA Keyence
Sale price $257.51
Only 9 units left

Specifications

Model

LV-11SA

Type

Main unit

Main unit/expansion unit

Applicable model

LV-S61/S41/S41L/S31/S71/S72

Control output

NPN open-collector × 2 channels, 40 VDC maximum, 100 mA or less per output

Response time

ExceptLV-S31

ULTRA

4 ms

SUPER

2 ms

TURBO

500 µs

FINE

250 µs

HSP

80 µs

LV-S31standard mode

500 µs

LV-S31standard mode

SPED2

2 ms

SPED3

8 ms

SPED4

32 ms

LV-S31High-speed mode

250 µs

Control input

Light emission stop input, external calibration, set value bank selection input, or received light intensity shift input

Number of interference prevention units

ULTRA

SUPER

TURBO

FINE

HSP

Unit expansion

Rating

Power voltage

12 to 24 VDC, Ripple (P-P) 10 % or less, Class2*1

Power consumption

Normal

1.5 W or less (62.5 mA or less at 24 V)

Eco-Half Eco-All

1.35 W or less (57.3 mA or less at 24 V)

Environmental resistance

Ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)*2

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z axis

Material

Main unit

Main body, cover: Polycarbonate

Weight

Approx. 80 g (including 2 m 6.6' cable)

*1 When more than 8 units connected, be sure to use supply voltage 24 VDC Ripple (P-P) 10 % or less
*2 To connect several units they must be mounted on a METAL DIN rail. Ensure that the output current is 20 mA max. With several units connected, the allowable ambient temperature range varies as follows: 1 to 2 units connected: -10 to +55 °C 14 to 131°F, 3 to 10 units connected: -10 to +50 °C 14 to 122°F, 11 to 16 units connected: -10 to +45 °C 14 to 113°F

keyence Stock Image
Keyence OP-88507 Keyence
Sale price$0.00
Sold Out

Specifications

Model

OP-88507

Type

High-flex

Sensor Side

M8 4-Pin Straight

Cable Connector

Loose wires

Length

10 m 32.8'

Material

Cable: PVC, Connector: Nickel-plated brass

Weight

Approx. 370 g

keyence Stock Image
Keyence OP-87287 Keyence
Sale price$0.00
Sold Out

Specifications

Model

OP-87287

Overview

O-ring used between the sensor main body of GP-M Series and the adapter.

Applicable product

GP-M001/M010/M025

Number included

1 pcs.

Material

FKM

keyence Stock Image
Keyence OP-89057 Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence SI-F1001 Keyence
Sale price$0.00
Sold Out

Specifications

Model

SI-F1001*1

Type

Main Controller Separate type*2

No. of connectable spectrum units

2

Display

Minimum display unit

0.001 µm

Display range

±999.999 µm to ±9999.99 mm (7 settings selectable)

Display cycle

10 times/sec.

Terminal block

Laser remote interlock input

Non-voltage input*3

TIMING1 input

RESET1 input

Auto-zero1 input

Laser control input

Analog voltage output

±10 V x 2 outputs, Output impedance: 100 Ω*3

Analog current output

4 to 20 mA x 2 outputs, Maximum load resistance: 350 Ω*3

Alarm output

NPN open-collector output (N.C.)*3

General comparator output

NPN open-collector output*3

Expansion connector

TIMING2 input

Non-voltage input*3

RESET input

Auto-zero input

Program switch input

Non-voltage input x 3 inputs*3

Alarm output

NPN open-collector output (N.C.)*3

Comparator/ binary output

Binary output

Measured value data output (21 bits) OUT selectable NPN open-collector output*3

Strobe output

NPN open-collector output*3

Binary selection output

Binary selection input

Non-voltage input*3

RS-232C interface

Measured data output and control input/output (Baud rate selectable to 115,200 bps max.)

USB interface

USB 2.0 high speed compliant (USB 1.1 Full-SPEED compatible)

Ethernet interface

100Base-TX/10Base-T

Major functions

12 Out simultaneous measurement
calculation, average, filter, scaling measurement, measured value alarm, tolerance setting, auto-zero, data storage, light monitor, 8-program memory,
interferometer mode, mask, connection of setting support software, etc.

Rating

Power voltage

24 VDC ±10 %, Ripple (P-P) 10 % or less

Current consumption

One head connected: 0.6 A or less. Six heads connected: 1.5 A or less.

Environmental resistance

Ambient temperature

0 to +50 °C 32 to 122 °F*4

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 0.5 mm 0.02", 2 hours in each of the X, Y, and Z directions

Weight

Approx. 600 g

*1 The SI-F1003 can be used independently, The measured value display and setting change can be done with the display panel(SI-FD500) and setup support software(SI-H3).
*2 The SI-F1001 can be used independently. The measured value display and setting change can be done with the display panel (SI-FD500) and setup support software (SI-H1).
*3 • NPN open-collector output rating: 50 mA max. (40 V max.), Residual voltage: 0.5 V max.
• Non-voltage input rating: ON voltage: 1 V max., OFF current: 0.6 mA max.
• Part of the input/output circuit of the SI Series is internally common. Be careful that no potential difference is generated between the internally common terminals due to the potential difference between the cables/external
devices. For details, refer to "Precautions on wiring".
*4 When two or more expansion controllers are connected, the ambient temperature is 0 to +40 °C 32 to 104 °F.

keyence Stock Image
Keyence GL-SA32F Keyence
Sale price$0.00
Sold Out

Specifications

Model

GL-SA32F

Type

Protection cover Flat type for 32 beam axes

Overview

This protective case protects the main unit from impacts.

Applicable product

GL-S32FH

Number included

1

Length

662.6 mm 26.09"

Material

aluminum

Note

2 each of the following are included: hexagon socket head cap screw (width across flats: 3 mm), washer, and special hexagon socket head cap screw (M4, length: 13 mm, width across flats: 3 mm).

Weight

210 g

keyence Stock Image
Keyence OP-82488 Keyence
Sale price$0.00
Sold Out

Specifications

Model

OP-82488

Type

Power cable

Applicable product

FT Series

Length

2 m 6.56'

Note

Included with amplifier

Weight

Approx. 55 g

keyence Stock Image
Keyence OP-88651 Keyence
Sale price$0.00
Sold Out

Specifications

Model

OP-88651

Type

M12/M12 Ethernet cable

Length

2 m 6.6'

Weight

約 160 g

keyence Stock Image
Keyence OP-84296 Keyence
Sale price$0.00
Sold Out

Specifications

Model

OP-84296

Type

Relay Box

Keyence Stock Image
Keyence GL-R23F Keyence
Sale price $750.80
Only 8 units left

Specifications

Model

GL-R23F

Detection capability

ø0.55" ø14 mm

Total length

9.45" 240mm

No. of beam

23

Detection height

8.66" 220mm

Protection height

9.61" 244mm

Beam axis spacing/Lens diameter

10 mm 0.39" / ø4 ø0.16"

Detecting distance

0.66 to 32.81' 0.2 to 10 m*1

Effective aperture angle

Max. ±2.5° (When operating distance is 9.84' 3 m or more)

Light source

Infrared LED (870 nm)

Response time (OSSD) (ms)

Wire synchronization, One-line or
Optical synchronization system (Channel 0)

ON→OFF

6.9

OFF→ON

49.2*2

All blocked→ON

64.4*3

Optical synchronization system
(Channel A or B)

ON→OFF

9.3

OFF→ON

52.7*2

All blocked→ON

74*3

Detection mode

Turns on when no interruptions are present in the detection zone

Synchronization between the transmitter and receiver

Optical synchronization or Wire synchronization (Determined by wiring)

Light interference prevention function

Prevents mutual interference in up to two GL-R systems.
Optical synchronization: prevented by Channel A and B with setting switch
Wire synchronization: prevented automatically

Control output
(OSSD output)

Output

2 transistor outputs. (PNP or NPN is determined by the cable type)

Max. load current

500 mA*4

Residual voltage (during ON)

Max. 2.5 V (with a cable length of 16.40' 5 m)

OFF state voltage

Max. 2.0 V (with a cable length of 16.40' 5 m)

Leakage current

Max. 200 µA

Max. capacitive load

2.2 µF

Load wiring resistance

Max. 2.5 Ω

Supplemental output
(Non-safety-related output)

AUX

transistor outputs. (PNP or NPN is determined by the cable type)
Load current: Max. 50 mA, Residual voltage: Max. 2.5 V (with a cable length of 16.40' 5 m)

Error output

Muting lamp output

Incandescent lamp (24 VDC, 1 to 5.5 W)
LED lamp (load current: 10 to 230 mA) can be connected.

External input

When using a PNP output cable

EDM input
Wait input
Reset input
Muting input 1, 2
Override input

ON voltage: 10 to 30 V
OFF voltage: Open or 0 to 3 V
Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only)

When using an NPN output cable

ON voltage: 0 to 3 V
OFF voltage: Open or 10 V or more
Up to the power voltage
Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only)

Power supply

Power voltage

24 VDC ±20%, ripple (P-P) 10% or less, Class 2

Current
consumption
(Max.) (mA)

Transmitter

50

Receiver

70

Protection circuit

Reverse current protection, short-circuit protection for each output, surge protection for each output

Approved standards

EMC

EMS

IEC61496-1, EN61496-1, UL61496-1

EMI

EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA

Safety

IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE)
IEC61496-2, EN61496-2, UL61496-2 (Type 4 AOPD)
IEC61508, EN61508 (SIL3), IEC62061, EN62061 (SIL CL3)
EN ISO13849-1:2015 (Category 4, PLe)
UL508
UL1998

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Overvoltage category

II

Ambient light

Incandescent lamp: 3,000 lux or less., Sunlight: 20,000 lux or less

Operating ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Operating relative humidity

15 to 85 % RH (No condensation)

Storage temperature

-25 to +60 °C -13 to 140 °F (No freezing)

Storage relative humidity

15 to 95 % RH

Vibration resistance

10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions

Shock resistance

100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Material

Main unit case

Aluminum

Upper case/lower case

Nylon (GF 30%)

Front cover

Polycarbonate, SUS304

Weight

Transmitter

320 g

Receiver

330 g

*1 When the option front protection cover is installed on the one of transmitter or receiver, the Operating distance is shorten by 1.64' 0.5 m. When the front covers are installed on both of the transmitter and receiver, the Operating distance is shorten by 3.28' 1.0 m.
*2 If the interruption is present in the detection zone for less than 80 ms, the response time (OFF to ON) will be 80 ms or more to ensure that the OSSD maintains the OFF state for more than 80 ms.
*3 “All blocked” means the situation where the GL-R operates in optical synchronization system and the
transmitter and receiver is not synchronized (top and bottom beam axes are both blocked). In this situation,
the response time is longer because the GL-R synchronizes the transmitter and receiver fi rst and then
determines the clear or blocked.
*4 When the GL-R is used under surrounding air temperatures between 50 to 55°C 122°F to 131°F, the Maximum load current should not exceed 350 mA.

Keyence Stock Image
Keyence FU-48 Keyence
Sale price $159.62
Only 9 units left

Specifications

Model

FU-48*1

Size

ø3 mm0.118"

Fibre unit length

2 m78.74" free-cut

Fibre unit diameter

ø1.0×2

Minimum bend radius

R4 mm0.157" high-flex

Minimum detectable object

Gold wire with a diameter of 0.005 mm0.0002" *2

Environmental resistance

Ambient temperature

-40 to +70 °C -40 to 158 °F

Weight

Approx. 7 g

*1 For details on the detecting distance, see the fiber amplifier catalog.
*2 The minimum detectable object is the value when the detecting distance and sensitivity have been set to their optimal state.

Recently viewed