Specifications
Model |
SI-F80R*1 |
|||
Type |
Wafer thickness measurement type Sensor head |
|||
Measurement range |
10 to 310 µm 0.000394" to 0.0122" (when n=3.5)*2 |
|||
Possible detection distance |
80 to 81.1 mm 3.15" to 3.19" |
|||
Light source |
Infrared SLD Output 0.6 mW, Class 1 Laser Product (IEC60825-1, FDA (CDRH) Part 1040.10*3) |
|||
Spot diameter |
ø25 µm ø0.000984"*4 |
|||
Linearity |
±0.1 µm ±0.000004" (when n=3.5)*5 |
|||
Resolution |
0.001 µm *6 |
|||
Sampling cycle |
200 µs |
|||
LED display |
Target near center of measurement range : green lights. Target within measurement range : orange lights. |
|||
Temperature fluctuation |
― |
|||
Environmental resistance |
Enclosure rating |
IP64 |
||
Ambient light |
Incandescent lamp or Fluorescent lamp: 10,000 lux max. |
|||
Ambient temperature |
0 to +50 °C 32 to 122 °F |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Material |
SUS |
|||
Weight |
Approx. 70 g (including cable) |
|||
*1 The sensor head and spectrum unit are calibrated as a pair. They are not interchangeable. | ||||


Specifications
Model |
GS-MAL5M |
|||
Type |
Coding level: Low |
|||
Applicable model |
Sliding door model GS-ML5 Series |
|||

Specifications
Model |
OP-80228 |
|||
Applicable product |
GT Series/GT2 Series |
|||
Note |
Fluorocarbon resin contact. (sold separately) |
|||

Specifications
Model |
SV-C5D |
|||
Type |
Motor power cable, Standard |
|||
Applicable product |
SV-100**/150**, SV-M100**/M150** |
|||
Length |
5 m 16.4' |
|||
Note |
for 1 k / 1.5 kW motor |
|||

Specifications
Model |
FU-97S*1 |
|||
Type |
Diffuse-reflective |
|||
Standard detection object |
Object with a diameter of 200, t = 0.7 mm0.028" glass substrate |
|||
Fibre unit length |
2 m78.74" free-cut |
|||
Fibre unit diameter |
ø2.2 |
|||
Minimum bend radius |
R40 mm1.575" |
|||
Tightening torque |
0.75 Nm or less |
|||
Environmental resistance |
Enclosure rating |
IP67*2 |
||
Ambient temperature |
-40 to +85 °C -40 to 185 °F (No condensation and no freezing)*3 |
|||
Relative humidity |
35 to 85 % RH (No freezing and No condensation)*4 |
|||
Material |
Main unit case : PFA, SUS316L; tube : PTFE*2 |
|||
Accessories |
Fiber cutter |
|||
Weight |
Approx. 90 g |
|||
*1 For details on the detecting distance, see the fiber amplifier catalog. | ||||


Specifications
Model |
KV-B16TD |
|||
Type |
Output unit |
|||
External connection method |
Removable terminal block |
|||
Output |
Number of outputs |
16 points |
||
Output mode |
MOSFET (sink) (with overcurrent protection function) |
|||
Rated load |
30 VDC, 0.3 A |
|||
Leakage current at OFF |
100 μA or less |
|||
Residual voltage at ON |
0.5 V or less |
|||
ON resistance |
- |
|||
Common method |
16 points/1 common (2 terminals)*1 |
|||
Operation time |
OFF to ON: 100 μs or less,ON to OFF: 300 μs or less |
|||
Internal current consumption |
45 mA or less |
|||
Weight |
Approx. 130 g |
|||
*1 Although KV-B16TD, KV-C32TD, KV-B16TCP, and KV-C32TCP have two points, they are the same internally. | ||||

Specifications
Model |
FS-N40 |
|||
Type |
Zero Line Type |
|||
Main unit/expansion unit |
Expansion unit |
|||
Response time |
23 µs (S-HSPD*1) /50 µs (HSPD*2) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA) /64 ms (TERA) |
|||
Number of control outputs |
None*3 |
|||
Light source LED |
Transmitter side: Red, four-element LED (wavelength: 660 nm) |
|||
External input |
Input time: 2 ms (ON) /20 ms (OFF) or longer*4 |
|||
Unit expansion |
Up to 16 units (17 units connected in total including the main unit) . However, each dual output type will be treated as two expansion units. |
|||
Protection circuit |
Protection against reverse power connection, output overcurrent, output surge, and reverse output connection |
|||
Mutual interference prevention |
S-HSPD/HSPD: 0 units, FINE: 4 units, TURBO/SUPER/ULTRA/MEGA/TERA: 8 units (The mutual interference prevention values are twice those shown here when Double is set.) |
|||
Power supply |
Power voltage |
10 to 30 VDC (including 10 % ripple (P-P) or less) , class 2 or LPS*5 |
||
Power consumption |
During normal operation: 870 mW or less (34 mA or less at 24 V/62 mA or less at 12 V) |
|||
Environmental resistance |
Ambient light |
Incandescent lamp: 20,000 lx or less, sunlight: 30,000 lx or less |
||
Ambient temperature |
-20 °C -4 °F to +55 °C +131 °F (no freezing)*7 |
|||
Vibration resistance |
10 to 55 Hz; double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axes |
|||
Shock resistance |
500 m/s2; 3 times each for X, Y, and Z axes |
|||
Case material |
Main unit and cover: polycarbonate |
|||
Weight |
Approx. 23 g |
|||
*1 Restrictions when S-HSPD is selected | ||||

Specifications
Model |
SV2-040L2 |
|||
General specifications |
Capacity |
400 W |
||
Input power supply |
Voltage/frequency |
Main circuit |
3-phase (or single phase) 200 to 240 VAC +10 to -15%, 50/60 Hz |
|
Control circuit |
Single-phase 200 to 240 VAC +10 to -15%, 50/60 Hz |
|||
Allowable frequency fluctuation |
Main circuit/control circuit |
No more than ±5% |
||
Overvoltage category |
III |
|||
Control mode |
Three-phase full-wave rectification, IGBT, PWM control, sine-wave current driving method |
|||
Feedback |
22-bit serial encoder (absolute) communication, |
|||
Operating environment |
Operating atmosphere |
Enclosure rating |
IP20 |
|
Pollution degree |
Pollution degree: 2 (in an IP54 or higher control panel) |
|||
Operating ambient temperature |
-5 to +60°C 23 to 140°F (no freezing; reduced ratings at +55°C 131°F or more) |
|||
Storage ambient temperature |
-20 to +85°C -4 to +185°F (no freezing) |
|||
Operating/storage ambient temperature |
95% RH or less (no condensation) |
|||
Altitude |
2000 m 6561.7' or less above sea level (usable at reduced ratings at 1000 m 3280.8' or more) |
|||
Vibration resistance |
4.9 m/s2 16.1'/s2 (JIS C60068-2-6 compliant) |
|||
Impact resistance |
19.6 m/s2 64.3'/s2 ( JIS C60068-2-27 compliant) |
|||
Other |
No static electricity noise, strong electric fields, magnetic fields, or radiation present |
|||
Min. insulation resistance |
500 VDC, 1 MΩ or more with insulation resistance tester |
|||
Applied standard |
UL/CSA standards |
UL61800-5-1, CSA22.2 No.274 |
||
CE marking |
Low-voltage directive |
EN61800-5-1, EN50178 |
||
EMI |
EN55011 Class A, EN61800-3, EN61000-6-4 |
|||
EMS |
EN61800-3, EN61000-6-2 |
|||
North America EMI standard |
FCC Part15 B, ICES-003. Class A |
|||
Structure |
Type |
Attached to base mount |
||
Safety function |
STO function (STO/EN61800-5-2) |
|||
Safety function |
Safety parameters |
SIL3/EN61508, SIL CL 3/EN62061, |
||
Response time |
8 ms (max.) |
|||
Input |
STO1, STO2: Base block signal for power module |
|||
Output |
EDM: Built-in safety circuit status monitoring (fixed output) |
|||
Applied standard |
EN61800-5-2, EN ISO13849-1: 2008, EN61508, EN62061, EN60204-1, EN61326-3-1 |
|||
Protection function |
Overcurrent, overvoltage, undervoltage, overload, regenerative abnormalities, etc. |
|||
Insulation withstand voltage |
1500 VAC or more (between primary side and ground) |
|||
Weight |
Approx. 1.0 kg |
|||
Power supply/current capacity and power loss |
Main circuit power supply |
Three-phase 200 V/Single phase 200 V |
||
Max. applicable motor capacity |
400 W |
|||
Power supply capacity for 1 amplifier |
Three-phase 200 V: 1 kVA, Single phase 200 V: 1.2 kVA |
|||
Output current |
Continuous |
2.8 Arms |
||
Max. |
9.3 Arms |
|||
Main circuit power loss |
24 W |
|||
Regenerative resistor power loss |
— |
|||
Control circuit power loss |
17 W |
|||
Total power loss |
41 W |
|||
Rated input current |
Main circuit |
Three-phase 200 V: 2.5 Arms, Single phase 200 V: 5.0 Arms |
||
Control circuit |
0.2 Arms |
|||
Rush current |
Main circuit |
34 A |
||
Control circuit | ||||
Performance specifications |
Performance |
Speed control range |
1:5000 (load torque ≤ rated torque conditions) |
|
Speed fluctuation rate |
At load fluctuation |
±0.01% or less with load fluctuations of 0 to 100% (at rated rotation speed) |
||
At main circuit voltage change |
0% with ±10% of rated voltage (at rated rotation speed) |
|||
At ambient temperature change |
±0.1% or less with ambient temperatures of 0 to +50°C 32 to 122°F (at rated rotation speed) |
|||
Torque control accuracy (reproducibility) |
±1% |
|||
Speed frequency response frequency |
2.6 kHz |
|||
Dynamic brake |
Operated at main circuit power supply OFF, servo alarm, limit switch detection (LSP/LSN), forced stop detection (FSTOP) |
|||
Regenerative resistor |
Built-in regenerative resistor: 50 W to 400 W ... not installed |
|||
Display Function |
Panel function |
7-segment LED |
||
Status display LED |
CHARGE: For notification of main circuit power supply input (orange) |
|||
Auxiliary function |
Gain control, alarm history, Z-phase search, etc. |
|||
I/O specifications |
Sequence input signal |
Number of inputs |
7 (3 high-speed input, 4 general input) |
|
Max. input voltage |
28.8 VDC |
|||
Rated input voltage |
24 VDC |
|||
Min. ON voltage |
19 VDC |
|||
Min. OFF current/voltage |
High-speed input: 0.6 mA, general input: 0.3 mA |
|||
Common point mode |
7 points/1 common point (1 terminal) (bidirectional) |
|||
Input time constant |
250 μs, 500 μs, 1 ms, 2.5 ms, 5 ms, 10 ms |
|||
Input current |
High-speed input: 4.5 mA, general input: 3.7 mA |
|||
Input impedance |
Approx. 4.7 kΩ |
|||
Assignable input signals |
Full signal assignment, logic-settable forced stop (FSTOP), |
|||
Sequence output signal |
Number of outputs |
4 |
||
Output mode |
Transistor NPN output |
|||
Rated load |
30 VDC / 50 mA |
|||
Leakage current when OFF |
0.1 mA |
|||
Residual voltage when ON |
1.5 VDC or less |
|||
Common point mode |
Independent common |
|||
Assignable output signals |
Individual signal assignment excluding ALARM signal, logic-settable alarm (ALARM), |
|||
Analog Feedback Input signal monitor |
Max. input voltage |
±12 V |
||
Accuracy |
±1% of F.S. |
|||
Resolution |
±10 bits |
|||
Input impedance |
30 kΩ |
|||
Encoder division pulse output signal |
Output mode |
Phase A (A+/A−), phase B(B+/B−), phase Z (Z+/Z−): Differential line-driver output |
||
Line driver |
SN75ALS174 (T.I.) or equivalent |
|||
Output frequency |
1.6 Mbps (with 2-phase, 4 times multiplication, 6.4 MHz or equivalent) *3 |
|||
Analog monitor output |
No. of channels |
2 ch |
||
Output range |
±10 V (linearity valid range ±8 V) |
|||
Resolution |
16 bits |
|||
Conversion precision |
±20 mV (typ.) |
|||
Max. allowable load current |
±10 mA |
|||
Conversion speed |
1.2 ms (typ.) |
|||
Communication specifications |
MECHATROLINK-III communication |
Communication protocol |
MECHATROLINK-III |
|
Station address |
03H to EFH (Max. number of connectable slaves: 62) |
|||
Transmission speed |
100 Mbps |
|||
Transmission frequency |
125 μs, 250 μs, 500 μs, 750 μs, 1 to 4 ms (in multiples of 0.5 ms) |
|||
Communication cycle |
Support for values starting at transmission frequency × 1 |
|||
Number of transmitted bytes |
32 bytes/station, 48 bytes/station (selectable with slide switch) |
|||
Transmission media/cable |
Category 5e-compliant, STP cross cable |
|||
Operating specifications |
Position control / speed control / torque control |
|||
Command input |
MECHATROLINK-III command |
|||
Max. transmission distance |
50 m 164.0' *4 |
|||
USB communication |
Connected device |
PC |
||
Communication standard |
USB 2.0-compliant |
|||
Function |
Status display, parameter setting, tuning, etc. |
|||
*1 When using a DC power supply input, set “*AC/DC power supply” to “DC”. | ||||

Specifications
Model |
CA-DRB8M |
|||
Type |
Multi-angle Light (Ring) |
|||
LED color |
Blue |
|||
Power consumption |
10.6 W |
|||
Input voltage |
12 VDC |
|||
Weight |
Approx. 150 g |
|||

Specifications
Model |
TM-H1X |
|||
Supported OS |
Windows11 Pro / Windows10 Home/Pro/Enterprise *1 |
|||
Required free space on hard disk |
2 GB or more (with additional space for storing images required) |
|||
Display resolution |
1366 × 768 pixels or higher (1920 × 1080 pixels or higher recommended) |
|||
*1 • Windows® is a trademark or registered trademark of Microsoft Corporation in the United States and other countries. | ||||

Specifications
Model |
SV2-BE3 |
|||
Type |
Encoder cable, Standard cable with battery |
|||
Length |
3 m 9.8' |
|||
Note |
for 50 to 750 W motor |
|||

Specifications
Model |
OP-42182 |
|||
Type |
Cable between the receiver and transmitter |
|||
Length |
1 m 3.3' |
|||
Note |
Up to two cables are connectable, provided that the total length is a maximum of 6 m 19.7'. |
|||
Weight |
Approx. 50 g |
|||

Specifications
Model |
GL-RC5M |
|||
Type |
Extension Cable |
|||
Applicable product |
GL-R Series |
|||
Number included |
1 cable |
|||
Cable end |
M14 connector (12-pin female) - Loose wires |
|||
Length |
5 m 16.40' |
|||
Material |
Connector for extension: PVC/nickel-plated brass, Cable: PVC |
|||
Note |
Extension cable for the GL-R Series. Use this together with the main unit connection cable (for extension). |
|||
Weight |
Approx. 245 g |
|||

Specifications
Model |
ER-GL30P03C |
|||
Type |
General-purpose all-metal shielded type Screw type M30 Connector with pigtail (M12 4-pin) PNP output Long-Range |
|||
Power supply cable length |
0.3 m 1.0' *1 |
|||
No. of control outputs |
2 |
|||
Output mode |
Output 1 |
N.O. |
||
Output 2 |
N.C. |
|||
Button |
None |
|||
Button |
Function |
― |
||
Detecting distance |
20 mm 0.79" ±10% *2 |
|||
Response frequency |
30 Hz *3 *4 |
|||
Hysteresis distance |
15% or less of detecting distance |
|||
Detectable object |
Magnetic metal, Non-magnetic metal *5 |
|||
Standard detectable object (Iron, t = 1 mm 0.04") |
60 × 60 mm 2.36" × 2.36" |
|||
Temperature characteristics |
±10% or less of detecting distance at +25°C +77°F (-25 to +55°C -13°F to +131°F) |
|||
Control output |
Open-collector, 30 VDC or less; 100 mA or less for 1 output; 100 mA or less in total for 2 outputs |
|||
Control output |
Residual voltage |
PNP output: 2.1 V or less (Output current: 10 mA or less) / 2.4 V or less (Output current: 10 to 100 mA) *6 |
||
Power supply |
Power voltage |
16 to 30 VDC (including 10% or less ripple (P-P)), Class 2 |
||
Power consumption (excluding load current) |
PNP output: 1140 mW or less (48 mA or less at 24 V, 72 mA or less at 16 V) |
|||
Protection circuit |
Protection against reverse power connections, output short-circuits, and reverse output connections |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529), IP67G (JIS C 0920) |
||
Ambient temperature |
-25 to +70°C -13°F to +158°F (no freezing) *7 |
|||
Relative humidity |
Up to 95% RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions |
|||
Shock resistance |
1000 m/s2 3280.8 ft/s2 (100 G), |
|||
Material |
Detecting surface: SUS303, Mounting screw: SUS303 (M30: SUS304), Case resin: PBT, Nut: SUS304, Toothed lock washer: SUS304 |
|||
Accessories |
Nut ×2, Toothed lock washer ×1 |
|||
Weight |
Approx. 150 g |
|||
*1 Ensure the power cable is no longer than 30 m 98.4' for connector and connector with pigtail types and no longer than 20 m 65.6' with IO-Link connections. | ||||

Specifications
Model |
OP-88867 |
|||
Supported models |
RB-500/800 |
|||
Weight |
Approx. 370 g per set (excluding attachment screws) |
|||

Specifications
Model |
SJ-H180C |
|||
Type |
HC |
|||
Ion generation method |
Corona discharge |
|||
Structure |
Shock-proof, resistance-coupled |
|||
Voltage application method/applied voltage |
Pulse AC method/±7000 V |
|||
Ion balance control method |
Dual I.C.C. method |
|||
Ion balance |
±30 V *1 |
|||
Cleanliness |
ISO 14644-1 Class 2 *2 |
|||
Operating distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
NPN open collector or non-voltage contact signal |
|||
Control output |
NPN type photorelay, 100 mA max. (at 40 V max.) |
|||
Major functions |
Condition alarm output, ion level alarm output, alarm output |
|||
Air purge connection port |
Rc 1/8 |
|||
Air purge supplied pressure |
0.5 MPa or less *3 |
|||
Effective length |
1800 mm 70.87" *4 |
|||
No. ofelectrodes |
28 |
|||
Static elimination bar length |
1760 mm 69.29" |
|||
Rating |
Power voltage |
24 VDC-36 V±10% |
||
Current consumption |
500 mA (at 24 VDC)/350 mA (at 36 VDC) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32.0°F to 104.0°F |
||
Relative humidity |
35 to 85% RH (No condensation) |
|||
Material |
Electrode probe |
Silicon |
||
Main unit |
ABS resin/PC |
|||
Weight |
Static elimination bar |
1750 g 61.73 oz |
||
*1 Value measured under the following conditions: | ||||


Specifications
Model |
AI-H020 |
|||
Installation Distance |
18 to 22 mm 0.71 to 0.87" |
|||
Detection Area |
1X Zoom to 4X Zoom |
1.4 × 1.4 mm 0.06 × 0.06" to 5.6 × 5.6 mm 0.22 × 0.22"*1 |
||
Digital Zoom |
1X to 4X (17 steps) adjustment, zoom position adjustment*1 |
|||
Light Receiving Element |
BW CMOS |
|||
Transmitter |
Light Source |
Red LED (660 nm) |
||
Lighting Method |
Pulse lighting |
|||
Indicators |
1 (green/red/orange) |
|||
Environmental resistance |
Enclosure rating |
- |
||
Ambient temperature |
-10 to +50 °C 14 to 122 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
500 m/s2, 3 times in each of 6 directions |
|||
Materials |
Main unit case: Zinc die-cast/PBT; Front cover: Acrylic (hard coat); Cable: PVC |
|||
Weight |
Approx. 50 g |
|||
*1 When positioned in the midpoint of the installation distance range. | ||||

Specifications
Model |
GL-R79F |
|||
Detection capability |
ø0.55" ø14 mm |
|||
Total length |
31.50" 800mm |
|||
No. of beam |
79 |
|||
Detection height |
30.71" 780mm |
|||
Protection height |
31.65" 804mm |
|||
Beam axis spacing/Lens diameter |
10 mm 0.39" / ø4 ø0.16" |
|||
Detecting distance |
0.66 to 32.81' 0.2 to 10 m*1 |
|||
Effective aperture angle |
Max. ±2.5° (When operating distance is 9.84' 3 m or more) |
|||
Light source |
Infrared LED (870 nm) |
|||
Response time (OSSD) (ms) |
Wire synchronization, One-line or |
ON→OFF |
13 |
|
OFF→ON |
58.2*2 |
|||
All blocked→ON |
88.6*3 |
|||
Optical synchronization system |
ON→OFF |
19 |
||
OFF→ON |
67.4*2 |
|||
All blocked→ON |
113*3 |
|||
Detection mode |
Turns on when no interruptions are present in the detection zone |
|||
Synchronization between the transmitter and receiver |
Optical synchronization or Wire synchronization (Determined by wiring) |
|||
Light interference prevention function |
Prevents mutual interference in up to two GL-R systems. |
|||
Control output |
Output |
2 transistor outputs. (PNP or NPN is determined by the cable type) |
||
Max. load current |
500 mA*4 |
|||
Residual voltage (during ON) |
Max. 2.5 V (with a cable length of 16.40' 5 m) |
|||
OFF state voltage |
Max. 2.0 V (with a cable length of 16.40' 5 m) |
|||
Leakage current |
Max. 200 µA |
|||
Max. capacitive load |
2.2 µF |
|||
Load wiring resistance |
Max. 2.5 Ω |
|||
Supplemental output |
AUX |
transistor outputs. (PNP or NPN is determined by the cable type) |
||
Error output | ||||
Muting lamp output |
Incandescent lamp (24 VDC, 1 to 5.5 W) |
|||
External input |
When using a PNP output cable |
EDM input |
ON voltage: 10 to 30 V |
|
When using an NPN output cable |
ON voltage: 0 to 3 V |
|||
Power supply |
Power voltage |
24 VDC ±20%, ripple (P-P) 10% or less, Class 2 |
||
Current |
Transmitter |
67 |
||
Receiver |
80 |
|||
Protection circuit |
Reverse current protection, short-circuit protection for each output, surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC61496-1, EN61496-1, UL61496-1 |
|
EMI |
EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA |
|||
Safety |
IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Overvoltage category |
II |
|||
Ambient light |
Incandescent lamp: 3,000 lux or less., Sunlight: 20,000 lux or less |
|||
Operating ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) |
|||
Operating relative humidity |
15 to 85 % RH (No condensation) |
|||
Storage temperature |
-25 to +60 °C -13 to 140 °F (No freezing) |
|||
Storage relative humidity |
15 to 95 % RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions |
|||
Shock resistance |
100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions |
|||
Material |
Main unit case |
Aluminum |
||
Upper case/lower case |
Nylon (GF 30%) |
|||
Front cover |
Polycarbonate, SUS304 |
|||
Weight |
Transmitter |
1200 g |
||
Receiver | ||||
*1 When the option front protection cover is installed on the one of transmitter or receiver, the Operating distance is shorten by 1.64' 0.5 m. When the front covers are installed on both of the transmitter and receiver, the Operating distance is shorten by 3.28' 1.0 m. | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
EV-18M*1 |
|||
Type |
AC , Shielded |
|||
Shape |
M18 |
|||
Detecting distance |
5 mm 0.20" ±10% |
|||
Detectable object |
Ferrous metals (see Characteristics for nonferrous metals) |
|||
Standard target |
18 x 18 mm 0.71" x 0.71" |
|||
Hysteresis |
10% max. of detecting distance |
|||
Response frequency |
25 Hz |
|||
Operation mode |
N.O. |
|||
Temperature characteristics |
±10% max. of detecting distance at 23°C 73.4°F, |
|||
Control output |
5 to 200 mA |
|||
Protection circuit |
Short-circuit |
|||
Cable length |
2 m 6.6' |
|||
Rating |
Power voltage |
24 to 240 VAC, 50/60 Hz |
||
Current consumption (leakage |
1.3 mA max. (at 240 VAC) |
|||
Residual voltage |
― |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Ambient temperature |
-25 to +80 °C -13 to 176 °F (No freezing) |
|||
Relative humidity |
35 to 95 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
1,000 m/s2, 3 times in each of the X, Y, and Z directions |
|||
Case material |
Nickel-plated brass |
|||
Accessories |
Nut × 2, toothed washer × 1, instruction manual |
|||
Weight |
Approx. 150 g |
|||
*1 This product does not comply with the EMC directive. | ||||