Model

NR-X100W

Main unit buffer memory capacity

50M data*1

Expansion memory

SD card (SD/SDHC)*2

PC interface

USB

USB mini-B connector, USB 2.0 High-speed–compliant, Simultaneous USB connection from one PC to up to four units (switchable by ID switch)

Ethernet

RJ45 connector, 100Base-TX (AUTO MDI/MDIX supported) *3

Wireless LAN

Connection via NR-XW1 wireless LAN unit, IEEE 802.11b/g/n *3

Network function

FTP client function, FTP server function, SNTP client function

Display/operation

Operation via NR-XCP30 control panel, or via WAVE LOGGER X with PC connection

Expansion remote unit connection

Dedicated remote connection connector × 2 (Remote OUT A port, B port)
Unit expansion possible by connecting up to eight NR-XR01 remote units (connected by remote unit cable)

Number of connectable measurement units

Master data collection unit group

Max. 8 units*4

Total with remote units connected

Max. 72 units*5

Continuous acquisition speed

Master data collection unit group

Max. 100 kHz for all acquisition channels *6

Total with remote units connected

Max. 500 kHz for all acquisition channels *6*7

Inter-unit synchronization

Between measurement units in the master data collection unit group

±1 μs or less *8

Between the master data collection unit and each remote unit / environment-resistant measurement unit

Time axis accuracy

±50 ppm (23°C ±3°C 73.4°F ±5.4°F); Same time used for all remote groups, SNTP server time synchronization possible

Synchronous trigger input (SYNC input)

Performance specifications

• Use as external trigger input (normal mode) or synchronous acquisition input (logging mode)
• Non-voltage (contact/non-contact)/voltage input, Falling edge input
• Not insulated from system bus

Input specifications

• For non-voltage input: ON voltage 1.0 V or lower (short circuit current: 1 mA typ.), OFF current 0.1 mA or lower
• For voltage input: ON voltage (Lo) 1.0 V or lower, OFF voltage (Hi) 2.4 V or more, Max. input voltage: 6 V

Control input

Common specifications

• Input type: Bidirectional voltage input
• Maximum rating: 30 VDC, Minimum ON voltage: 10 VDC, Maximum OFF current: 0.2 mA
• Insulation between input and system bus (500 VDC/1 minute)

Individual specifications

• External trigger input (TRG IN): Edge input
• Acquisition start/stop input (START IN): Level input (only enabled in external control mode)
• Auto-balance input (BAL): Edge input (only enabled in external control mode)
• Program selection input 0 to 3 (PROG IN0 to 3): Level input (only enabled in external control mode)

Control output

Common specifications

• Output format: Photo MOS relay output
• Maximum rating: 36 VDC, Output current: 50 mA or less (9-point total: 300 mA or less)
• Leak current at OFF: 0.1 mA or less, Residual voltage when ON: 1 V or less
• Insulation between output and system bus (500 VDC/1 minute)

Individual specifications

• Trigger output (TRG OUT): N.O. output, one-shot output
• System error output (SYS ERR): N.C. output
• Alarm output (ALARM): N.O. output
• Judgment output 1 to 4 (OUT1 to 4): N.O. output
• Ready output (READY): N.O. output

Power supply

• NR-XU1 AC adapter, or 9 to 36 VDC (including ripple) / Max. 72 W (when connected to DC terminal block; at 9 V: 8.0 A or less; at 24 V: 3.0 A or less; at 36 V: 2.0 A or less)
• Battery operation possible when connected to the NR-XU15 Series battery power supply unit

Power supply

Power consumption

8.4 W or less (excluding connected units)

Environmental resistance

Ambient temperature

0 to +40°C 32°F to 104°F

Relative humidity

10 to 85% RH (no condensation)

Weight

Approx. 490 g 17.30 oz (including approx. 10 g 0.35 oz for the OP-88512 (NR-X100W I/O terminal block))

*1 Data is not backed up when the power is turned off. The available data buffer memory per NR-X100W and NR-XR01 group is limited to 25M.
*2 Use only products recommended by KEYENCE (CA-SD4G: 4 GB, CA-SD16G: 16 GB). Using a product not recommended by KEYENCE may result in data not being saved to the SD card during continuous acquisition.
*3 Wired LAN and wireless LAN cannot be used at the same time. When acquiring data from a PC (using WAVE LOGGER X software), use a wired local connection only between the NR-X100W and the PC. Using an onsite local network connection or wireless LAN connection may cause acquisition to stop due to a decrease in transfer speeds caused by network load or wireless LAN communication conditions. The main unit’s automatic saving function allows data to be saved to an SD card in the main unit even if acquisition by PC stops.
*4 Use is permitted only if the total power consumption of all connected measurement units is 20 W or less.
*5 Use is permitted only if the total power consumption of all measurement units, remote units, and environment-resistant measurement units used in the system is 50 W or less when remote units are not connected to an AC adapter.
*6 Acquisition from a PC may not be possible in some PC environments. [Tested conditions] OS: Windows 10 Pro (64 bit), CPU: 3.70 GHz, RAM: 16.0 GB, USB connections: One NR-X100W (no other USB devices), Ethernet connection: One-to-one connection between NR-X100W and PC; Using normal mode and saving in the standard format with a pre-installed OS and running only WAVE LOGGER X. Windows is a registered trademark or a trademark of Microsoft Corporation in the United States and/or other countries.
*7 Each master data collection unit group and remote unit group is limited to 100 kHz for all acquisition channels. When using 5 or more remote units, each remote unit group can have up to 50 kHz per acquisition channel.
*8 The sampling cycle and sampling timing vary depending on the connected measurement unit. When using the NR‑CA04 in combination with other unit types, a sampling delay may occur between the NR-CA04 and the other units with some setting configurations.


Sale price$3,265.99
1-year warranty
FREE WORDWIDE SHIPPING
Est. delivery between and  
Estimated delivery dates are estimates only. Int'l customers allow a few more days. For more precise delivery estimates, please contact us at support@plc-direct.com. Contact us in advance for expedited shipping options.
Condition:
$0.00
$3,265.99
$0.00

Ach Direct Debit American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa
Description
Warranty
Shipping and Return

Specifications

Model

NR-X100W

Main unit buffer memory capacity

50M data*1

Expansion memory

SD card (SD/SDHC)*2

PC interface

USB

USB mini-B connector, USB 2.0 High-speed–compliant, Simultaneous USB connection from one PC to up to four units (switchable by ID switch)

Ethernet

RJ45 connector, 100Base-TX (AUTO MDI/MDIX supported) *3

Wireless LAN

Connection via NR-XW1 wireless LAN unit, IEEE 802.11b/g/n *3

Network function

FTP client function, FTP server function, SNTP client function

Display/operation

Operation via NR-XCP30 control panel, or via WAVE LOGGER X with PC connection

Expansion remote unit connection

Dedicated remote connection connector × 2 (Remote OUT A port, B port)
Unit expansion possible by connecting up to eight NR-XR01 remote units (connected by remote unit cable)

Number of connectable measurement units

Master data collection unit group

Max. 8 units*4

Total with remote units connected

Max. 72 units*5

Continuous acquisition speed

Master data collection unit group

Max. 100 kHz for all acquisition channels *6

Total with remote units connected

Max. 500 kHz for all acquisition channels *6*7

Inter-unit synchronization

Between measurement units in the master data collection unit group

±1 μs or less *8

Between the master data collection unit and each remote unit / environment-resistant measurement unit

Time axis accuracy

±50 ppm (23°C ±3°C 73.4°F ±5.4°F); Same time used for all remote groups, SNTP server time synchronization possible

Synchronous trigger input (SYNC input)

Performance specifications

• Use as external trigger input (normal mode) or synchronous acquisition input (logging mode)
• Non-voltage (contact/non-contact)/voltage input, Falling edge input
• Not insulated from system bus

Input specifications

• For non-voltage input: ON voltage 1.0 V or lower (short circuit current: 1 mA typ.), OFF current 0.1 mA or lower
• For voltage input: ON voltage (Lo) 1.0 V or lower, OFF voltage (Hi) 2.4 V or more, Max. input voltage: 6 V

Control input

Common specifications

• Input type: Bidirectional voltage input
• Maximum rating: 30 VDC, Minimum ON voltage: 10 VDC, Maximum OFF current: 0.2 mA
• Insulation between input and system bus (500 VDC/1 minute)

Individual specifications

• External trigger input (TRG IN): Edge input
• Acquisition start/stop input (START IN): Level input (only enabled in external control mode)
• Auto-balance input (BAL): Edge input (only enabled in external control mode)
• Program selection input 0 to 3 (PROG IN0 to 3): Level input (only enabled in external control mode)

Control output

Common specifications

• Output format: Photo MOS relay output
• Maximum rating: 36 VDC, Output current: 50 mA or less (9-point total: 300 mA or less)
• Leak current at OFF: 0.1 mA or less, Residual voltage when ON: 1 V or less
• Insulation between output and system bus (500 VDC/1 minute)

Individual specifications

• Trigger output (TRG OUT): N.O. output, one-shot output
• System error output (SYS ERR): N.C. output
• Alarm output (ALARM): N.O. output
• Judgment output 1 to 4 (OUT1 to 4): N.O. output
• Ready output (READY): N.O. output

Power supply

• NR-XU1 AC adapter, or 9 to 36 VDC (including ripple) / Max. 72 W (when connected to DC terminal block; at 9 V: 8.0 A or less; at 24 V: 3.0 A or less; at 36 V: 2.0 A or less)
• Battery operation possible when connected to the NR-XU15 Series battery power supply unit

Power supply

Power consumption

8.4 W or less (excluding connected units)

Environmental resistance

Ambient temperature

0 to +40°C 32°F to 104°F

Relative humidity

10 to 85% RH (no condensation)

Weight

Approx. 490 g 17.30 oz (including approx. 10 g 0.35 oz for the OP-88512 (NR-X100W I/O terminal block))

*1 Data is not backed up when the power is turned off. The available data buffer memory per NR-X100W and NR-XR01 group is limited to 25M.
*2 Use only products recommended by KEYENCE (CA-SD4G: 4 GB, CA-SD16G: 16 GB). Using a product not recommended by KEYENCE may result in data not being saved to the SD card during continuous acquisition.
*3 Wired LAN and wireless LAN cannot be used at the same time. When acquiring data from a PC (using WAVE LOGGER X software), use a wired local connection only between the NR-X100W and the PC. Using an onsite local network connection or wireless LAN connection may cause acquisition to stop due to a decrease in transfer speeds caused by network load or wireless LAN communication conditions. The main unit’s automatic saving function allows data to be saved to an SD card in the main unit even if acquisition by PC stops.
*4 Use is permitted only if the total power consumption of all connected measurement units is 20 W or less.
*5 Use is permitted only if the total power consumption of all measurement units, remote units, and environment-resistant measurement units used in the system is 50 W or less when remote units are not connected to an AC adapter.
*6 Acquisition from a PC may not be possible in some PC environments. [Tested conditions] OS: Windows 10 Pro (64 bit), CPU: 3.70 GHz, RAM: 16.0 GB, USB connections: One NR-X100W (no other USB devices), Ethernet connection: One-to-one connection between NR-X100W and PC; Using normal mode and saving in the standard format with a pre-installed OS and running only WAVE LOGGER X. Windows is a registered trademark or a trademark of Microsoft Corporation in the United States and/or other countries.
*7 Each master data collection unit group and remote unit group is limited to 100 kHz for all acquisition channels. When using 5 or more remote units, each remote unit group can have up to 50 kHz per acquisition channel.
*8 The sampling cycle and sampling timing vary depending on the connected measurement unit. When using the NR‑CA04 in combination with other unit types, a sampling delay may occur between the NR-CA04 and the other units with some setting configurations.

All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.

If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.

In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.

PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.

Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.

PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.

Description
Warranty
Shipping and Return

Specifications

Model

NR-X100W

Main unit buffer memory capacity

50M data*1

Expansion memory

SD card (SD/SDHC)*2

PC interface

USB

USB mini-B connector, USB 2.0 High-speed–compliant, Simultaneous USB connection from one PC to up to four units (switchable by ID switch)

Ethernet

RJ45 connector, 100Base-TX (AUTO MDI/MDIX supported) *3

Wireless LAN

Connection via NR-XW1 wireless LAN unit, IEEE 802.11b/g/n *3

Network function

FTP client function, FTP server function, SNTP client function

Display/operation

Operation via NR-XCP30 control panel, or via WAVE LOGGER X with PC connection

Expansion remote unit connection

Dedicated remote connection connector × 2 (Remote OUT A port, B port)
Unit expansion possible by connecting up to eight NR-XR01 remote units (connected by remote unit cable)

Number of connectable measurement units

Master data collection unit group

Max. 8 units*4

Total with remote units connected

Max. 72 units*5

Continuous acquisition speed

Master data collection unit group

Max. 100 kHz for all acquisition channels *6

Total with remote units connected

Max. 500 kHz for all acquisition channels *6*7

Inter-unit synchronization

Between measurement units in the master data collection unit group

±1 μs or less *8

Between the master data collection unit and each remote unit / environment-resistant measurement unit

Time axis accuracy

±50 ppm (23°C ±3°C 73.4°F ±5.4°F); Same time used for all remote groups, SNTP server time synchronization possible

Synchronous trigger input (SYNC input)

Performance specifications

• Use as external trigger input (normal mode) or synchronous acquisition input (logging mode)
• Non-voltage (contact/non-contact)/voltage input, Falling edge input
• Not insulated from system bus

Input specifications

• For non-voltage input: ON voltage 1.0 V or lower (short circuit current: 1 mA typ.), OFF current 0.1 mA or lower
• For voltage input: ON voltage (Lo) 1.0 V or lower, OFF voltage (Hi) 2.4 V or more, Max. input voltage: 6 V

Control input

Common specifications

• Input type: Bidirectional voltage input
• Maximum rating: 30 VDC, Minimum ON voltage: 10 VDC, Maximum OFF current: 0.2 mA
• Insulation between input and system bus (500 VDC/1 minute)

Individual specifications

• External trigger input (TRG IN): Edge input
• Acquisition start/stop input (START IN): Level input (only enabled in external control mode)
• Auto-balance input (BAL): Edge input (only enabled in external control mode)
• Program selection input 0 to 3 (PROG IN0 to 3): Level input (only enabled in external control mode)

Control output

Common specifications

• Output format: Photo MOS relay output
• Maximum rating: 36 VDC, Output current: 50 mA or less (9-point total: 300 mA or less)
• Leak current at OFF: 0.1 mA or less, Residual voltage when ON: 1 V or less
• Insulation between output and system bus (500 VDC/1 minute)

Individual specifications

• Trigger output (TRG OUT): N.O. output, one-shot output
• System error output (SYS ERR): N.C. output
• Alarm output (ALARM): N.O. output
• Judgment output 1 to 4 (OUT1 to 4): N.O. output
• Ready output (READY): N.O. output

Power supply

• NR-XU1 AC adapter, or 9 to 36 VDC (including ripple) / Max. 72 W (when connected to DC terminal block; at 9 V: 8.0 A or less; at 24 V: 3.0 A or less; at 36 V: 2.0 A or less)
• Battery operation possible when connected to the NR-XU15 Series battery power supply unit

Power supply

Power consumption

8.4 W or less (excluding connected units)

Environmental resistance

Ambient temperature

0 to +40°C 32°F to 104°F

Relative humidity

10 to 85% RH (no condensation)

Weight

Approx. 490 g 17.30 oz (including approx. 10 g 0.35 oz for the OP-88512 (NR-X100W I/O terminal block))

*1 Data is not backed up when the power is turned off. The available data buffer memory per NR-X100W and NR-XR01 group is limited to 25M.
*2 Use only products recommended by KEYENCE (CA-SD4G: 4 GB, CA-SD16G: 16 GB). Using a product not recommended by KEYENCE may result in data not being saved to the SD card during continuous acquisition.
*3 Wired LAN and wireless LAN cannot be used at the same time. When acquiring data from a PC (using WAVE LOGGER X software), use a wired local connection only between the NR-X100W and the PC. Using an onsite local network connection or wireless LAN connection may cause acquisition to stop due to a decrease in transfer speeds caused by network load or wireless LAN communication conditions. The main unit’s automatic saving function allows data to be saved to an SD card in the main unit even if acquisition by PC stops.
*4 Use is permitted only if the total power consumption of all connected measurement units is 20 W or less.
*5 Use is permitted only if the total power consumption of all measurement units, remote units, and environment-resistant measurement units used in the system is 50 W or less when remote units are not connected to an AC adapter.
*6 Acquisition from a PC may not be possible in some PC environments. [Tested conditions] OS: Windows 10 Pro (64 bit), CPU: 3.70 GHz, RAM: 16.0 GB, USB connections: One NR-X100W (no other USB devices), Ethernet connection: One-to-one connection between NR-X100W and PC; Using normal mode and saving in the standard format with a pre-installed OS and running only WAVE LOGGER X. Windows is a registered trademark or a trademark of Microsoft Corporation in the United States and/or other countries.
*7 Each master data collection unit group and remote unit group is limited to 100 kHz for all acquisition channels. When using 5 or more remote units, each remote unit group can have up to 50 kHz per acquisition channel.
*8 The sampling cycle and sampling timing vary depending on the connected measurement unit. When using the NR‑CA04 in combination with other unit types, a sampling delay may occur between the NR-CA04 and the other units with some setting configurations.

All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.

If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.

In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.

PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.

Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.

PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.

Trusted By

"Fast service for obsolete parts"

Increasingly PLC/ HMI control platforms are becoming obsolete and parts are no longer supported, however PLC Direct had the HMI we needed and fast shipping for our system to get back online!

Buyer at GE Health

"Helping us move projects forward"

With supply chain issues increasingly affecting our business, PLC Direct has been there for us to supply the PLC products we need, when we need it. If they don't have it readily available, they find it and provide it quickly and reliably. This has helped us move forward with several projects that would have otherwise taken us many, many months to complete.

Buyer at E-Merge Systems – A Rockwell Integrator

You may also like

Recently viewed