Specifications
Model |
XM-5000A |
|||
Camera unit |
Maximum measurement length |
W × D × H |
500 × 300 × 200 mm 19.69" × 11.81" × 7.87" |
|
Indication error accuracy |
±(7 + 9L/1000) μm *1 |
|||
Repeatability |
±3 μm |
|||
Minimum display unit |
Distance |
0.0001 mm 0.000004" |
||
Angle |
0.0001 degrees |
|||
Camera unit rotation angle |
Theta rotation |
±25° |
||
Tilt rotation |
±20° |
|||
Weight |
Approx. 8 kg 17.64 lb |
|||
External input |
2 inputs |
Maximum applied voltage: 26.4 V, ON voltage: 19 V or more, OFF current: 0.1 mA or less |
||
External output |
7 outputs (OK/NG/FAIL/MEASURE/ERROR/TOUCH/STROBE) |
Maximum applied voltage: 30 V, Maximum sink current: 50 mA, |
||
Probe |
Number of possible connections |
1 |
||
Communication unit |
USB communication |
USB 3.0 |
||
Infrared communication |
945 nm |
|||
Power supply |
Supplied from dedicated AC adapter |
|||
Rating |
Rated voltage |
24 VDC |
||
Current consumption |
1.7 A |
|||
Environmental resistance |
Operating ambient temperature |
10 to 35°C 50 to 95°F |
||
Operating ambient humidity |
20 to 80% RH (no condensation) |
|||
Probe |
Marker |
Number of markers |
7 |
|
Light source |
870 nm |
|||
Applicable stylus |
M5 |
|||
Display |
Display method |
OLED |
||
Resolution |
96 × 39 pixels |
|||
Hardware keys |
MEASURE, OK, CANCEL, CAMERA, Trigger, Power |
|||
Communication unit |
USB communication |
USB 2.0 |
||
Infrared communication |
945 nm |
|||
Rating |
USB connection |
Rated voltage |
5 VDC |
|
Current consumption |
1 A |
|||
Environmental resistance |
Operating ambient temperature |
10 to 35°C 50 to 95°F |
||
Operating ambient humidity |
20 to 80% RH (no condensation) |
|||
Weight |
Approx. 630 g 22.24 oz |
|||
*1 Refer to ISO 10360-2 (in the range of 200 × 200 × 150 mm 7.87" × 7.87" × 5.91" and when the ambient temperature is 20°C ±1°C 68 ±1.8°F; “L” represents the measurement length (Unit: mm inch)) | ||||


Specifications
Model |
EV-108M |
|||
Type |
Shielded |
|||
Shape |
M8 |
|||
Detecting distance |
1.5 mm 0.06" ±10% |
|||
Detectable object |
Ferrous metals (see Characteristics for nonferrous metals) |
|||
Standard target |
10 x 10 mm 0.39" x 0.39" |
|||
Hysteresis |
10% max. of detecting distance |
|||
Response frequency |
800 Hz |
|||
Operation mode |
N.O. |
|||
Temperature characteristics |
±10% max. of detecting distance at 23°C 73.4°F, |
|||
Control output |
5 to 80 mA |
|||
Protection circuit |
Reversed polarity,surge voltage |
|||
Cable length |
2 m 6.6' |
|||
Rating |
Power voltage |
12 to 24 VDC, Ripple (P-P) 20 % or less |
||
Current consumption (leakage |
Current consumption (leakage current): 1.0 mA max., Residual voltage: 3.6 V max. (with 2-m 6.6' cable) |
|||
Residual voltage |
Residual voltage: 3.6 V max. (with 2-m 6.6' cable) |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Ambient temperature |
-25 to +80 °C -13 to 176 °F (No freezing) |
|||
Relative humidity |
35 to 95 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
500 m/s2, 3 times in each of the X, Y, and Z directions |
|||
Case material |
Stainless steel (SUS304) |
|||
Accessories |
Nut × 2, toothed washer × 1, instruction manual |
|||
Weight |
Approx. 42 g |
|||

Specifications
Model |
ER-30N |
|||
Type |
Ultra-long distance shielded type Screw type M30 Cable NPN output |
|||
Power supply cable length |
2 m 6.6' *1 |
|||
No. of control outputs |
1 |
|||
Output mode |
Output 1 |
N.O. |
||
Output 2 |
― |
|||
Button |
Available |
|||
Button |
Function |
Distance switching, Through-Metal |
||
Detecting distance |
With default settings (Mode 1) |
26 mm 1.02" ±10% *2 |
||
With distance switching (Mode 2) |
20 mm 0.79" ±10% *2 |
|||
Response frequency |
With default settings (Mode 1) |
15 Hz *3 *4 |
||
With distance switching (Mode 2) |
30 Hz *3 *4 |
|||
Hysteresis distance |
15% or less of detecting distance |
|||
Detectable object |
Magnetic metal, Non-magnetic metal *5 |
|||
Standard detectable object (Iron, t = 1 mm 0.04") |
78 × 78 mm 3.07" × 3.07" |
|||
Temperature characteristics |
±10% or less of detecting distance at +25°C +77°F (-25 to +55°C -13°F to +131°F) |
|||
Control output |
Open-collector, 30 VDC or less |
|||
Control output |
Residual voltage |
NPN output: 0.9 V or less (Output current: 10 mA or less) / |
||
Power supply |
Power voltage |
16 to 30 VDC (including 10% or less ripple (P-P)), Class 2 |
||
Power consumption (excluding load current) |
NPN output: 1040 mW or less (44 mA or less at 24 V, 65 mA or less at 16 V) |
|||
Protection circuit |
Protection against reverse power connections, output short-circuits, and reverse output connections |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529) |
||
Ambient temperature |
-25 to +70°C -13°F to +158°F (no freezing) *7 |
|||
Relative humidity |
Up to 95% RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions |
|||
Shock resistance |
1000 m/s2 3280.8 ft/s2 (100 G), 10 times in each of the X, Y, and Z directions |
|||
Material |
Detecting surface: LCP, Mounting screw: SUS303 (M30: SUS304), Case resin: PBT, Button: PBT, Nut: SUS304, Toothed lock washer: SUS304 |
|||
Accessories |
Nut ×2, Toothed lock washer ×1 |
|||
Weight |
Approx. 175 g |
|||
*1 Ensure the power cable is no longer than 30 m 98.4' for connector and connector with pigtail types and no longer than 20 m 65.6' with IO-Link connections. | ||||




PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
FU-68*1 |
|||
Size |
M4 |
|||
Fibre unit length |
2 m78.74" free-cut |
|||
Fibre unit diameter |
ø1.0×2 |
|||
Minimum bend radius |
R4 mm0.157" high-flex |
|||
Minimum detectable object |
Gold wire with a diameter of 0.005 mm0.0002" *2 |
|||
Environmental resistance |
Ambient temperature |
-40 to +70 °C -40 to 158 °F |
||
Weight |
Approx. 8 g |
|||
*1 For details on the detecting distance, see the fiber amplifier catalog. | ||||

Specifications
Model |
MP-FN10R |
|||
Type |
Standard model |
|||
Connection bore diameter |
NPT3/8" (10 A) |
|||
Supported gases |
Air and non-corrosive gases |
|||
Supported gas temperature |
-5 to +50°C, 23 to 122°F |
|||
Operating pressure range |
0.2 to 1 MPa, 2 to 10 bar, 29 to 145 psi *1 |
|||
Pressure resistance |
1.5 MPa, 15 bar, 217.5 psi |
|||
Flow rate |
Detection principle |
Heat based (mass flow rate) |
||
Rated flow range (normal) |
2.0 to 1000.0 L/min |
|||
Zero cut flow rate |
2.0 L/min, 0.12 m3/h 4.24 ft3/h, 0.07 CFM |
|||
Measurement accuracy |
±(1.5% of RD + 0.5% of F.S.) *2 *3 |
|||
Repeatability |
±1.0% of F.S. (with an averaging time of 1.0 s) |
|||
Display resolution |
0.1 L/min, 0.01 m3/h 0.35 ft3/h, 0.01 CFM |
|||
Response time |
150 ms (63% response) *4 |
|||
Averaging time |
OFF/100 ms/200 ms/500 ms/1.0 s/3.0 s/5.0 s/10 s/30 s (selectable) |
|||
Pressure (Digital value, gauge pressure) |
Rated pressure range |
0.000 to 1.000 MPa, 0.00 to 10.00bar, 0.0 to 145.0 psi |
||
Measurement accuracy |
±2.0% of F.S. |
|||
Repeatability |
±0.2% of F.S. (with a response time of 50 ms) |
|||
Display resolution |
0.001 MPa, 0.01 bar, 0.1 psi |
|||
Response time |
Selectable from 10 ms, 50 ms, 100 ms, 500 ms, 1.0 s, and 5.0 s *4 |
|||
Humidity (Dew point) |
Rated relative humidity range/ dew point range |
15 to 100%RH (no condensation)/Corresponds to the relative humidity range *5 *6 |
||
Measurement accuracy |
±4°C, ±7°F *5 *6 |
|||
Display resolution |
5%RH/1°C, 1°F *5 *6 |
|||
Temperature |
Measurement accuracy |
±2.0°C, ±3.6°F *7 |
||
Display resolution |
0.1°C, 0.1°F *7 |
|||
Shut-off valve |
Response time |
1 s or less (closed → open) |
||
Leakage amount |
50 mL/min 0.002 CFM (N) or less |
|||
Filter/regulator (Standard model only) |
Pressure adjustment range |
0.15 to 0.90 MPa |
||
Filtration degree |
5 μm 0.196850 Mil |
|||
Drainage cup capacity |
60 cc |
|||
Check valve |
Available |
|||
Display |
Color LCD, status indicator |
|||
Data accumulation |
Accumulation period |
Accumulated data: approx. 2 years/Instantaneous data: approx. 2 weeks |
||
Data reading |
USB 2.0/Ethernet |
|||
I/O |
Control output (Ch.1/2/3/4/5) |
NPN/PNP setting switchable, open collector output 30 VDC or less, N.O./N.C. setting switchable, max. 100 mA/Ch., residual voltage: 2.5 V or less |
||
Analog output (Ch.1/2) |
4 to 20 mA, load resistance: 260 Ω or less *4 |
|||
External input (Ch.2/3/6) |
Short-circuit current: 1.5 mA or less, input time: 20 ms or more |
|||
Protection circuit |
Power supply reverse connection protection, power supply surge protection, reverse connection protection for each I/O, surge protection for each I/O, overcurrent protection for each output |
|||
Power supply |
Power voltage |
24 VDC +25%/-20% (including ripple), Class 2 or LPS |
||
Power consumption |
1.2 A (300 ms) when opening/closing valve, 100 mA at all other times *8 (standalone usage; excluding load current) |
|||
Communication interface |
USB2.0 |
|||
Network compatibility |
When using only this unit: IO-Link (Specification v1.1/COM3) *9 |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529) *10 |
||
Ambient temperature |
−5°C to +50°C 23°F to 122°F (no freezing) *11 |
|||
Relative humidity |
35%RH to 85%RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz; power spectral density: 0.204 G2/Hz; X, Y, and Z directions |
|||
Shock resistance |
300 m/s2, XYZ axes, 10 times for each axis |
|||
Material |
Sensor part : PET/PPS/PBT/POM/aluminum/SPHC |
|||
Weight |
Approx. 1050 g 37.04 oz (excluding drainage cup) |
|||
*1 An upstream side pressure of 0.2 MPa or less (a filter/regulator adjustment pressure of 0.2 MPa or less for the standard model) worsens the flow rate characteristic of the shut-off valve. | ||||



Specifications
Model |
GL-SA08F |
|||
Type |
Protection cover Flat type for 8 beam axes |
|||
Overview |
This protective case protects the main unit from impacts. |
|||
Applicable product |
GL-S08FH |
|||
Number included |
1 |
|||
Length |
182.6 mm 7.19" |
|||
Material |
aluminum |
|||
Note |
2 each of the following are included: hexagon socket head cap screw (width across flats: 3 mm), washer, and special hexagon socket head cap screw (M4, length: 13 mm, width across flats: 3 mm). |
|||
Weight |
60 g |
|||

Specifications
Model |
GL-R95F |
|||
Detection capability |
ø0.55" ø14 mm |
|||
Total length |
37.80" 960mm |
|||
No. of beam |
95 |
|||
Detection height |
37.01" 940mm |
|||
Protection height |
37.95" 964mm |
|||
Beam axis spacing/Lens diameter |
10 mm 0.39" / ø4 ø0.16" |
|||
Detecting distance |
0.66 to 32.81' 0.2 to 10 m*1 |
|||
Effective aperture angle |
Max. ±2.5° (When operating distance is 9.84' 3 m or more) |
|||
Light source |
Infrared LED (870 nm) |
|||
Response time (OSSD) (ms) |
Wire synchronization, One-line or |
ON→OFF |
14.7 |
|
OFF→ON |
60.8*2 |
|||
All blocked→ON |
95.5*3 |
|||
Optical synchronization system |
ON→OFF |
21.8 |
||
OFF→ON |
71.5*2 |
|||
All blocked→ON |
124.1*3 |
|||
Detection mode |
Turns on when no interruptions are present in the detection zone |
|||
Synchronization between the transmitter and receiver |
Optical synchronization or Wire synchronization (Determined by wiring) |
|||
Light interference prevention function |
Prevents mutual interference in up to two GL-R systems. |
|||
Control output |
Output |
2 transistor outputs. (PNP or NPN is determined by the cable type) |
||
Max. load current |
500 mA*4 |
|||
Residual voltage (during ON) |
Max. 2.5 V (with a cable length of 16.40' 5 m) |
|||
OFF state voltage |
Max. 2.0 V (with a cable length of 16.40' 5 m) |
|||
Leakage current |
Max. 200 µA |
|||
Max. capacitive load |
2.2 µF |
|||
Load wiring resistance |
Max. 2.5 Ω |
|||
Supplemental output |
AUX |
transistor outputs. (PNP or NPN is determined by the cable type) |
||
Error output | ||||
Muting lamp output |
Incandescent lamp (24 VDC, 1 to 5.5 W) |
|||
External input |
When using a PNP output cable |
EDM input |
ON voltage: 10 to 30 V |
|
When using an NPN output cable |
ON voltage: 0 to 3 V |
|||
Power supply |
Power voltage |
24 VDC ±20%, ripple (P-P) 10% or less, Class 2 |
||
Current |
Transmitter |
71 |
||
Receiver |
83 |
|||
Protection circuit |
Reverse current protection, short-circuit protection for each output, surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC61496-1, EN61496-1, UL61496-1 |
|
EMI |
EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA |
|||
Safety |
IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Overvoltage category |
II |
|||
Ambient light |
Incandescent lamp: 3,000 lux or less., Sunlight: 20,000 lux or less |
|||
Operating ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) |
|||
Operating relative humidity |
15 to 85 % RH (No condensation) |
|||
Storage temperature |
-25 to +60 °C -13 to 140 °F (No freezing) |
|||
Storage relative humidity |
15 to 95 % RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions |
|||
Shock resistance |
100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions |
|||
Material |
Main unit case |
Aluminum |
||
Upper case/lower case |
Nylon (GF 30%) |
|||
Front cover |
Polycarbonate, SUS304 |
|||
Weight |
Transmitter |
1400 g |
||
Receiver | ||||
*1 When the option front protection cover is installed on the one of transmitter or receiver, the Operating distance is shorten by 1.64' 0.5 m. When the front covers are installed on both of the transmitter and receiver, the Operating distance is shorten by 3.28' 1.0 m. | ||||

Specifications
Model |
BT-H1AGA |
|||
Type |
BT Application Design Tool |
|||
Operating System |
Development PC: |
|||
CPU |
Intel Core i5 2.60 GHz or higher |
|||
Memory capacity |
4 GB or higher |
|||
Available hard disk space |
1GB or higher |
|||
Display |
1366 × 768 or higher |
|||

Specifications
Model |
FR-LEXB42 |
|||
Type |
Zener barrier |
|||
Input/Output |
2-wire system |
|||
Explosion-Proof Specifications |
[AEx ia Ga] IIB |
|||

Specifications
Model |
GL-SB04 |
|||
Type |
Adjustable anglemounting bracket |
|||
Applicable product |
GL-S Series main unit |
|||
Number included |
Two each for bilateral symmetry |
|||
Material |
PPS, SUS430, SUS303, NBR, and neodymium magnet |
|||
Note |
The beam axis can be adjusted within a range of ±15°. |
|||
Weight |
40 g |
|||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.


Specifications
Model |
OP-84403 |
|||
Type |
I/O connector cable |
|||
Applicable product |
SV |
|||
Cable end |
26-pin, Loose wire on one side |
|||
Length |
3 m 9.8' |
|||
Note |
Can be used with the MECHATROLINK-II type. |
|||