Machine Vision Systems

5768 products

Showing 721 - 744 of 5768 products

Showing 721 - 744 of 5768 products
View
Keyence Stock Image
Keyence KV-1000 Keyence
Sale price $575.01
Only 6 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

keyence Stock Image
Keyence XM-5000A Keyence
Sale price$0.00
Sold Out

Specifications

Model

XM-5000A

Camera unit

Maximum measurement length

W × D × H

500 × 300 × 200 mm 19.69" × 11.81" × 7.87"

Indication error accuracy

±(7 + 9L/1000) μm *1

Repeatability

±3 μm

Minimum display unit

Distance

0.0001 mm 0.000004"

Angle

0.0001 degrees

Camera unit rotation angle

Theta rotation

±25°

Tilt rotation

±20°

Weight

Approx. 8 kg 17.64 lb

External input

2 inputs

Maximum applied voltage: 26.4 V, ON voltage: 19 V or more, OFF current: 0.1 mA or less

External output

7 outputs (OK/NG/FAIL/MEASURE/ERROR/TOUCH/STROBE)

Maximum applied voltage: 30 V, Maximum sink current: 50 mA,
Leakage current: 0.1 mA or less, Residual voltage: 1.4 V or less (50 mA) / 1.0 V or less (20 mA)

Probe

Number of possible connections

1

Communication unit

USB communication

USB 3.0

Infrared communication

945 nm

Power supply

Supplied from dedicated AC adapter

Rating

Rated voltage

24 VDC

Current consumption

1.7 A

Environmental resistance

Operating ambient temperature

10 to 35°C 50 to 95°F

Operating ambient humidity

20 to 80% RH (no condensation)

Probe

Marker

Number of markers

7

Light source

870 nm

Applicable stylus

M5

Display

Display method

OLED

Resolution

96 × 39 pixels

Hardware keys

MEASURE, OK, CANCEL, CAMERA, Trigger, Power

Communication unit

USB communication

USB 2.0

Infrared communication

945 nm

Rating

USB connection

Rated voltage

5 VDC

Current consumption

1 A

Environmental resistance

Operating ambient temperature

10 to 35°C 50 to 95°F

Operating ambient humidity

20 to 80% RH (no condensation)

Weight

Approx. 630 g 22.24 oz

*1 Refer to ISO 10360-2 (in the range of 200 × 200 × 150 mm 7.87" × 7.87" × 5.91" and when the ambient temperature is 20°C ±1°C 68 ±1.8°F; “L” represents the measurement length (Unit: mm inch))

keyence Stock Image
Keyence OP-88248 Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence Stock Image
Keyence EV-108M Keyence
Sale price $157.50
Only 9 units left

Specifications

Model

EV-108M

Type

Shielded

Shape

M8

Detecting distance

1.5 mm 0.06" ±10%

Detectable object

Ferrous metals (see Characteristics for nonferrous metals)

Standard target
(iron, t=1 mm 0.04")

10 x 10 mm 0.39" x 0.39"

Hysteresis

10% max. of detecting distance

Response frequency

800 Hz

Operation mode

N.O.

Temperature characteristics

±10% max. of detecting distance at 23°C 73.4°F,
within -25 to +70°C -13 to +158°F

Control output
(switching capacity)

5 to 80 mA

Protection circuit

Reversed polarity,surge voltage

Cable length

2 m 6.6'

Rating

Power voltage

12 to 24 VDC, Ripple (P-P) 20 % or less

Current consumption (leakage
current)

Current consumption (leakage current): 1.0 mA max., Residual voltage: 3.6 V max. (with 2-m 6.6' cable)

Residual voltage

Residual voltage: 3.6 V max. (with 2-m 6.6' cable)

Environmental resistance

Enclosure rating

IP67

Ambient temperature

-25 to +80 °C -13 to 176 °F (No freezing)

Relative humidity

35 to 95 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

500 m/s2, 3 times in each of the X, Y, and Z directions

Case material

Stainless steel (SUS304)

Accessories

Nut × 2, toothed washer × 1, instruction manual

Weight

Approx. 42 g

keyence Stock Image
Keyence ER-30N Keyence
Sale price$0.00
Sold Out

Specifications

Model

ER-30N

Type

Ultra-long distance shielded type Screw type M30 Cable NPN output

Power supply cable length

2 m 6.6' *1

No. of control outputs

1

Output mode

Output 1

N.O.

Output 2

Button

Available

Button

Function

Distance switching, Through-Metal

Detecting distance

With default settings (Mode 1)

26 mm 1.02" ±10% *2

With distance switching (Mode 2)

20 mm 0.79" ±10% *2

Response frequency

With default settings (Mode 1)

15 Hz *3 *4

With distance switching (Mode 2)

30 Hz *3 *4

Hysteresis distance

15% or less of detecting distance

Detectable object

Magnetic metal, Non-magnetic metal *5

Standard detectable object (Iron, t = 1 mm 0.04")

78 × 78 mm 3.07" × 3.07"

Temperature characteristics

±10% or less of detecting distance at +25°C +77°F (-25 to +55°C -13°F to +131°F)
±15% or less of detecting distance at +25°C +77°F (+55 to +70°C 131°F to 158°F)

Control output

Open-collector, 30 VDC or less
100 mA or less for 1 output, or 100 mA or less in total for 2 outputs

Control output

Residual voltage

NPN output: 0.9 V or less (Output current: 10 mA or less) /
1.4 V or less (Output current: 10 to 100 mA) *6

Power supply

Power voltage

16 to 30 VDC (including 10% or less ripple (P-P)), Class 2

Power consumption (excluding load current)

NPN output: 1040 mW or less (44 mA or less at 24 V, 65 mA or less at 16 V)

Protection circuit

Protection against reverse power connections, output short-circuits, and reverse output connections

Environmental resistance

Enclosure rating

IP67 (IEC60529)

Ambient temperature

-25 to +70°C -13°F to +158°F (no freezing) *7

Relative humidity

Up to 95% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions

Shock resistance

1000 m/s2 3280.8 ft/s2 (100 G), 10 times in each of the X, Y, and Z directions

Material

Detecting surface: LCP, Mounting screw: SUS303 (M30: SUS304), Case resin: PBT, Button: PBT, Nut: SUS304, Toothed lock washer: SUS304
[Connector] Indicator: PBT (M8: LCP), Connector: PBT (M8: LCP), Case: SUS303
[Connector with pigtail] Indicator: TPU, Cable cap (M8 only): PBT, Cable: PVC, Connector resin: TPU, Connector metal: Nickel-plated brass
[Cable] Indicator: TPU, Cable cap (M8 only): PBT, Cable: PVC

Accessories

Nut ×2, Toothed lock washer ×1

Weight

Approx. 175 g
6.18 oz

*1 Ensure the power cable is no longer than 30 m 98.4' for connector and connector with pigtail types and no longer than 20 m 65.6' with IO-Link connections.
*2 The distance at which a standard detectable object can be detected when the unit is mounted without being affected by surrounding metal.
*3 Value when a standard detectable object is used, the distance between detectable objects is twice the standard detectable object, and the distance to the detection target is 1/2 the detecting distance.
*4 The response frequency varies depending on the operating temperature. The response frequency at temperatures of +55°C +131°F or higher is 50% of that at +25°C +77°F.
*5 Detecting distance varies according to the material and size. See the characteristic diagrams for details.
*6 Residual voltage is for when a 2 m 6.6' cable is used.
*7 The upper limit of the UL temperature rating is +55℃ +131℉.

Keyence New Stock Image
Keyence AH-06321 Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-89261 Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence CA-E100T Keyence
Sale price $4,302.10
Only 6 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence Stock Image
Keyence UD-310 Keyence
Sale price $1,855.09
Only 7 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Keyence Stock Image
Keyence FU-68 Keyence
Sale price $136.38
In stock, 12 units

Specifications

Model

FU-68*1

Size

M4

Fibre unit length

2 m78.74" free-cut

Fibre unit diameter

ø1.0×2

Minimum bend radius

R4 mm0.157" high-flex

Minimum detectable object

Gold wire with a diameter of 0.005 mm0.0002" *2

Environmental resistance

Ambient temperature

-40 to +70 °C -40 to 158 °F

Weight

Approx. 8 g

*1 For details on the detecting distance, see the fiber amplifier catalog.
*2 The minimum detectable object is the value when the detecting distance and sensitivity have been set to their optimal state.

keyence Stock Image
Keyence MP-FN10R Keyence
Sale price$0.00
Sold Out

Specifications

Model

MP-FN10R

Type

Standard model

Connection bore diameter

NPT3/8" (10 A)

Supported gases

Air and non-corrosive gases

Supported gas temperature

-5 to +50°C, 23 to 122°F

Operating pressure range

0.2 to 1 MPa, 2 to 10 bar, 29 to 145 psi *1

Pressure resistance

1.5 MPa, 15 bar, 217.5 psi

Flow rate

Detection principle

Heat based (mass flow rate)

Rated flow range (normal)

2.0 to 1000.0 L/min
0.12 to 60.00 m3/h 4.24 to 2118.88 ft3/h 0.07 to 35.31 CFM

Zero cut flow rate

2.0 L/min, 0.12 m3/h 4.24 ft3/h, 0.07 CFM

Measurement accuracy

±(1.5% of RD + 0.5% of F.S.) *2 *3

Repeatability

±1.0% of F.S. (with an averaging time of 1.0 s)

Display resolution

0.1 L/min, 0.01 m3/h 0.35 ft3/h, 0.01 CFM

Response time

150 ms (63% response) *4

Averaging time

OFF/100 ms/200 ms/500 ms/1.0 s/3.0 s/5.0 s/10 s/30 s (selectable)

Pressure (Digital value, gauge pressure)

Rated pressure range

0.000 to 1.000 MPa, 0.00 to 10.00bar, 0.0 to 145.0 psi

Measurement accuracy

±2.0% of F.S.

Repeatability

±0.2% of F.S. (with a response time of 50 ms)

Display resolution

0.001 MPa, 0.01 bar, 0.1 psi

Response time

Selectable from 10 ms, 50 ms, 100 ms, 500 ms, 1.0 s, and 5.0 s *4

Humidity (Dew point)

Rated relative humidity range/ dew point range

15 to 100%RH (no condensation)/Corresponds to the relative humidity range *5 *6

Measurement accuracy

±4°C, ±7°F *5 *6

Display resolution

5%RH/1°C, 1°F *5 *6

Temperature

Measurement accuracy

±2.0°C, ±3.6°F *7

Display resolution

0.1°C, 0.1°F *7

Shut-off valve

Response time

1 s or less (closed → open)

Leakage amount

50 mL/min 0.002 CFM (N) or less

Filter/regulator (Standard model only)

Pressure adjustment range

0.15 to 0.90 MPa

Filtration degree

5 μm 0.196850 Mil

Drainage cup capacity

60 cc

Check valve

Available

Display

Color LCD, status indicator

Data accumulation

Accumulation period

Accumulated data: approx. 2 years/Instantaneous data: approx. 2 weeks

Data reading

USB 2.0/Ethernet

I/O

Control output (Ch.1/2/3/4/5)

NPN/PNP setting switchable, open collector output 30 VDC or less, N.O./N.C. setting switchable, max. 100 mA/Ch., residual voltage: 2.5 V or less

Analog output (Ch.1/2)

4 to 20 mA, load resistance: 260 Ω or less *4

External input (Ch.2/3/6)

Short-circuit current: 1.5 mA or less, input time: 20 ms or more

Protection circuit

Power supply reverse connection protection, power supply surge protection, reverse connection protection for each I/O, surge protection for each I/O, overcurrent protection for each output

Power supply

Power voltage

24 VDC +25%/-20% (including ripple), Class 2 or LPS

Power consumption

1.2 A (300 ms) when opening/closing valve, 100 mA at all other times *8 (standalone usage; excluding load current)

Communication interface

USB2.0

Network compatibility

When using only this unit: IO-Link (Specification v1.1/COM3) *9
When connecting MP-FEN1 : EtherNet/IP™, PROFINET, Modbus/TCP, MC protocol/SLMP

Environmental resistance

Enclosure rating

IP67 (IEC60529) *10

Ambient temperature

−5°C to +50°C 23°F to 122°F (no freezing) *11

Relative humidity

35%RH to 85%RH (no condensation)

Vibration resistance

10 to 500 Hz; power spectral density: 0.204 G2/Hz; X, Y, and Z directions

Shock resistance

300 m/s2, XYZ axes, 10 times for each axis

Material

Sensor part : PET/PPS/PBT/POM/aluminum/SPHC
Filter/regulator : Aluminum/POM/HDPE/NBR/Nylon *12

Weight

Approx. 1050 g 37.04 oz (excluding drainage cup)

*1 An upstream side pressure of 0.2 MPa or less (a filter/regulator adjustment pressure of 0.2 MPa or less for the standard model) worsens the flow rate characteristic of the shut-off valve.
*2 This value is guaranteed by KEYENCE inspection facilities while testing with air. Errors will be introduced by factors such as the gas type, gas temperature, and ambient temperature.
*3 Value in an environment with a constant temperature of 25°C 77°F and compressed air evaluated as purity class 1*1 (ISO 8573-1 (2010)/JIS B 8392-1 (2012)).±(5.5% of RD + 0.5% of F.S.) when equivalent to purity class 3*4.
*4 15 ms is added to the analog output response time.
*5 Measurable when at least 2% of F.S. worth of gas is flowing.
*6 The prescribed accuracy may not be met or the unit may be damaged if the compressed air contains a large amount of oil mist, organic solvent, or other gas. (For details, see “Gas Being Measured” on page 4.)
*7 When the flow is 5% of F.S. or higher. Errors due to heat generated by the main unit occur when the flow is too small.
*8 When connecting MP-FEA1 and/or MP-FEN1, add each device’s current consumption (2.1 A or less including load current).
*9 Use an IO-Link master that can supply 1.2 A or more. (1.6 A or less when connecting an MP-FEA1 and an MP-FEN1.) IO-Link is a registered trademark or trademark of PROFIBUS Nutzerorganisation e.V. (PNO).
*10 When protection is provided to prevent dust and liquid from intruding through the exhaust port. The IP67 enclosure rating is lost when a USB connection is established.
*11 If this product is used with a power supply voltage of 26.4 V or more, the upper limit on the ambient temperature is 45°C 113°F.
*12 Nylon is only used on the MP-Fx20R.

Keyence New Stock Image
Keyence IT2-50 Keyence
Sale price $1,980.69
Only 7 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence CA-DRW3 Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence GL-SA08F Keyence
Sale price$0.00
Sold Out

Specifications

Model

GL-SA08F

Type

Protection cover Flat type for 8 beam axes

Overview

This protective case protects the main unit from impacts.

Applicable product

GL-S08FH

Number included

1

Length

182.6 mm 7.19"

Material

aluminum

Note

2 each of the following are included: hexagon socket head cap screw (width across flats: 3 mm), washer, and special hexagon socket head cap screw (M4, length: 13 mm, width across flats: 3 mm).

Weight

60 g

Keyence Stock Image
Keyence GL-R95F Keyence
Sale price $1,894.19
In stock, 12 units

Specifications

Model

GL-R95F

Detection capability

ø0.55" ø14 mm

Total length

37.80" 960mm

No. of beam

95

Detection height

37.01" 940mm

Protection height

37.95" 964mm

Beam axis spacing/Lens diameter

10 mm 0.39" / ø4 ø0.16"

Detecting distance

0.66 to 32.81' 0.2 to 10 m*1

Effective aperture angle

Max. ±2.5° (When operating distance is 9.84' 3 m or more)

Light source

Infrared LED (870 nm)

Response time (OSSD) (ms)

Wire synchronization, One-line or
Optical synchronization system (Channel 0)

ON→OFF

14.7

OFF→ON

60.8*2

All blocked→ON

95.5*3

Optical synchronization system
(Channel A or B)

ON→OFF

21.8

OFF→ON

71.5*2

All blocked→ON

124.1*3

Detection mode

Turns on when no interruptions are present in the detection zone

Synchronization between the transmitter and receiver

Optical synchronization or Wire synchronization (Determined by wiring)

Light interference prevention function

Prevents mutual interference in up to two GL-R systems.
Optical synchronization: prevented by Channel A and B with setting switch
Wire synchronization: prevented automatically

Control output
(OSSD output)

Output

2 transistor outputs. (PNP or NPN is determined by the cable type)

Max. load current

500 mA*4

Residual voltage (during ON)

Max. 2.5 V (with a cable length of 16.40' 5 m)

OFF state voltage

Max. 2.0 V (with a cable length of 16.40' 5 m)

Leakage current

Max. 200 µA

Max. capacitive load

2.2 µF

Load wiring resistance

Max. 2.5 Ω

Supplemental output
(Non-safety-related output)

AUX

transistor outputs. (PNP or NPN is determined by the cable type)
Load current: Max. 50 mA, Residual voltage: Max. 2.5 V (with a cable length of 16.40' 5 m)

Error output

Muting lamp output

Incandescent lamp (24 VDC, 1 to 5.5 W)
LED lamp (load current: 10 to 230 mA) can be connected.

External input

When using a PNP output cable

EDM input
Wait input
Reset input
Muting input 1, 2
Override input

ON voltage: 10 to 30 V
OFF voltage: Open or 0 to 3 V
Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only)

When using an NPN output cable

ON voltage: 0 to 3 V
OFF voltage: Open or 10 V or more
Up to the power voltage
Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only)

Power supply

Power voltage

24 VDC ±20%, ripple (P-P) 10% or less, Class 2

Current
consumption
(Max.) (mA)

Transmitter

71

Receiver

83

Protection circuit

Reverse current protection, short-circuit protection for each output, surge protection for each output

Approved standards

EMC

EMS

IEC61496-1, EN61496-1, UL61496-1

EMI

EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA

Safety

IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE)
IEC61496-2, EN61496-2, UL61496-2 (Type 4 AOPD)
IEC61508, EN61508 (SIL3), IEC62061, EN62061 (SIL CL3)
EN ISO13849-1:2015 (Category 4, PLe)
UL508
UL1998

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Overvoltage category

II

Ambient light

Incandescent lamp: 3,000 lux or less., Sunlight: 20,000 lux or less

Operating ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Operating relative humidity

15 to 85 % RH (No condensation)

Storage temperature

-25 to +60 °C -13 to 140 °F (No freezing)

Storage relative humidity

15 to 95 % RH

Vibration resistance

10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions

Shock resistance

100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Material

Main unit case

Aluminum

Upper case/lower case

Nylon (GF 30%)

Front cover

Polycarbonate, SUS304

Weight

Transmitter

1400 g

Receiver

*1 When the option front protection cover is installed on the one of transmitter or receiver, the Operating distance is shorten by 1.64' 0.5 m. When the front covers are installed on both of the transmitter and receiver, the Operating distance is shorten by 3.28' 1.0 m.
*2 If the interruption is present in the detection zone for less than 80 ms, the response time (OFF to ON) will be 80 ms or more to ensure that the OSSD maintains the OFF state for more than 80 ms.
*3 “All blocked” means the situation where the GL-R operates in optical synchronization system and the
transmitter and receiver is not synchronized (top and bottom beam axes are both blocked). In this situation,
the response time is longer because the GL-R synchronizes the transmitter and receiver fi rst and then
determines the clear or blocked.
*4 When the GL-R is used under surrounding air temperatures between 50 to 55°C 122°F to 131°F, the Maximum load current should not exceed 350 mA.

keyence Stock Image
Keyence BT-H1AGA Keyence
Sale price$0.00
Sold Out

Specifications

Model

BT-H1AGA

Type

BT Application Design Tool

Operating System

Development PC:
Windows 7 Professional / Windows 8 Professional / Windows 8.1 Professional (32/64 bit) / Windows 10 Professional (32bit/64bit)
Operation PC:
Windows 7 Professional / Windows 8 Professional / Windows 8.1 Professional (32/64 bit) / Windows 10 Professional (32bit/64bit)
Windows Server 2008 R2 Standard / Windows Server 2012/2012 R2 Standard (64 bit)

CPU

Intel Core i5 2.60 GHz or higher

Memory capacity

4 GB or higher

Available hard disk space

1GB or higher

Display

1366 × 768 or higher

keyence Stock Image
Keyence FR-LEXB42 Keyence
Sale price$0.00
Sold Out

Specifications

Model

FR-LEXB42

Type

Zener barrier

Input/Output

2-wire system

Explosion-Proof Specifications

[AEx ia Ga] IIB
[AEx ia Da] IIIC

keyence Stock Image
Keyence GL-SB04 Keyence
Sale price$0.00
Sold Out

Specifications

Model

GL-SB04

Type

Adjustable anglemounting bracket

Applicable product

GL-S Series main unit

Number included

Two each for bilateral symmetry

Material

PPS, SUS430, SUS303, NBR, and neodymium magnet

Note

The beam axis can be adjusted within a range of ±15°.

Weight

40 g

Keyence Stock Image
Keyence VT3-X15 Keyence
Sale price $3,040.83
Only 8 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

keyence Stock Image
Keyence OP-87752 Keyence
Sale price$0.00
Sold Out

Specifications

Model

OP-87752

Type

Air purge unit

Number included

1 pc

Weight

400 g

keyence Stock Image
Keyence OP-51592 Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-84403 Keyence
Sale price$0.00
Sold Out

Specifications

Model

OP-84403

Type

I/O connector cable

Applicable product

SV

Cable end

26-pin, Loose wire on one side

Length

3 m 9.8'

Note

Can be used with the MECHATROLINK-II type.

Keyence New Stock Image
Keyence XG-X2900 Keyence
Sale price $5,310.20
Only 7 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence Stock Image
Keyence CA-MP82 Keyence
Sale price $937.50
Only 4 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Recently viewed