KV-CA02 Keyence

Specifications

Model

KV-CA02 *1

General specifications

Power voltage

System configuration using an expansion unit for KV-5000/3000 Series: 24 VDC (±10%)*2
System configuration using an expansion unit only for KV-8000/7000 Series: 24 VDC (-15%/+20%)*2

Operating ambient temperature

System configuration using an expansion unit for KV-5000/3000 Series: 0 to +50°C 32 to 122°F
(no freezing)*3*4
System configuration using an expansion unit only for KV-8000/7000 Series: 0 to +55°C 32 to 131°F
(no freezing)*3*4

Operating ambient humidity

System configuration using an expansion unit for KV-5000/3000 Series: 10 to 95% RH
(no condensation)*3
System configuration using an expansion unit only for KV-8000/7000 Series: 5 to 95% RH
(no condensation)*3

Storage ambient temperature

System configuration using an expansion unit for KV-5000/3000 Series: -20 to +70°C -4 to +158°F*3
System configuration using an expansion unit only for KV-8000/7000 Series: -25 to +75°C -13 to +167°F*3

Storage relative humidity

System configuration using an expansion unit for KV-5000/3000 Series: 10 to 95% RH
(no condensation)*3
System configuration using an expansion unit only for KV-8000/7000 Series: 5 to 95% RH
(no condensation)*3

Operating environment

No dust or corrosive gas

Operating altitude

2000 m 6561.7' or less

Noise immunity

1500 Vp-p or more
Pulse duration: 1 μs, 50 ns (based on noise simulator)
IEC standard-compliant (IEC 61000-4-2/3/4/6)

Withstand voltage

1500 VAC for one minute (between the power terminals and the I/O terminals, and between the external terminals and the case)

Insulation resistance

50 MΩ or more (between the power terminals and the I/O terminals and between the external terminals and the case, with 500 VDC megohmmeter)

Vibration resistance

Intermittent vibration

Frequency 5 to 9 Hz

Half amplitude 3.5 mm 0.14"*5

Frequency 9 to 150 Hz

Acceleration 9.8 m/s2 32.2'/s2*5

Continuous vibration

Frequency 5 to 9 Hz

Half amplitude 1.75 mm 0.07"*5

Frequency 9 to 150 Hz

Acceleration 4.9 m/s2 16.1'/s2*5

Shock resistance

Acceleration: 150 m/s2 492.1'/s2, Application time: 11 ms, 2 times in each of the X, Y, and Z directions

Pollution degree

2

Performance specifications

Connectable CPU unit

KV-X Series/KV-8000A

Max. number of connectable units

4

Number of ports

2

Supported camera models

KV-CA1H (Compact standard camera)
KV-CA1W (Wide-field high-resolution camera)

Cable length

5/10/20 m 16.4'/32.8'/65.6'*6

Recording time

Approx. 3 minutes*7

Internal current consumption

260 mA or less*8

Weight

Approx. 190 g

*1 for use with KV-X/KV-8000 Series
*2 Supplied via the CPU unit or expansion unit.
*3 Guaranteed range in which the system can be used.
*4 Specified according to the temperature in the control panel on the lower side of the unit.
*5 Compliant with JIS B 3502 IEC 61131-2, Scan times: 10 times in each of the X, Y, and Z directions (for 100 min.)
*6 Lengths of the KV-C5/C10/C20 camera cables.
*7 Record time for one KV-CA1H with the following configuration of settings (initial value). The actual recording time varies depending on the number of devices, the frame rate, and the image quality settings. Frame rate: 30 fps/Quality: 3
In addition, the recorded video is cleared when the power is turned off.
*8 Internal current consumption for the KV-CA02 only. Connecting a camera adds the internal current consumption of the connected camera.

Est. delivery between and    
Estimated delivery dates are estimates only. Int'l customers allow a few more days. For more precise delivery estimates, please contact us at support@plc-direct.com. Contact us in advance for expedited shipping options.
Sale price$517.50
1-year warranty
FREE WORDWIDE SHIPPING
Condition:
$0.00
$517.50
$0.00
Ach Direct Debit American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa

Specifications

Model

KV-CA02 *1

General specifications

Power voltage

System configuration using an expansion unit for KV-5000/3000 Series: 24 VDC (±10%)*2
System configuration using an expansion unit only for KV-8000/7000 Series: 24 VDC (-15%/+20%)*2

Operating ambient temperature

System configuration using an expansion unit for KV-5000/3000 Series: 0 to +50°C 32 to 122°F
(no freezing)*3*4
System configuration using an expansion unit only for KV-8000/7000 Series: 0 to +55°C 32 to 131°F
(no freezing)*3*4

Operating ambient humidity

System configuration using an expansion unit for KV-5000/3000 Series: 10 to 95% RH
(no condensation)*3
System configuration using an expansion unit only for KV-8000/7000 Series: 5 to 95% RH
(no condensation)*3

Storage ambient temperature

System configuration using an expansion unit for KV-5000/3000 Series: -20 to +70°C -4 to +158°F*3
System configuration using an expansion unit only for KV-8000/7000 Series: -25 to +75°C -13 to +167°F*3

Storage relative humidity

System configuration using an expansion unit for KV-5000/3000 Series: 10 to 95% RH
(no condensation)*3
System configuration using an expansion unit only for KV-8000/7000 Series: 5 to 95% RH
(no condensation)*3

Operating environment

No dust or corrosive gas

Operating altitude

2000 m 6561.7' or less

Noise immunity

1500 Vp-p or more
Pulse duration: 1 μs, 50 ns (based on noise simulator)
IEC standard-compliant (IEC 61000-4-2/3/4/6)

Withstand voltage

1500 VAC for one minute (between the power terminals and the I/O terminals, and between the external terminals and the case)

Insulation resistance

50 MΩ or more (between the power terminals and the I/O terminals and between the external terminals and the case, with 500 VDC megohmmeter)

Vibration resistance

Intermittent vibration

Frequency 5 to 9 Hz

Half amplitude 3.5 mm 0.14"*5

Frequency 9 to 150 Hz

Acceleration 9.8 m/s2 32.2'/s2*5

Continuous vibration

Frequency 5 to 9 Hz

Half amplitude 1.75 mm 0.07"*5

Frequency 9 to 150 Hz

Acceleration 4.9 m/s2 16.1'/s2*5

Shock resistance

Acceleration: 150 m/s2 492.1'/s2, Application time: 11 ms, 2 times in each of the X, Y, and Z directions

Pollution degree

2

Performance specifications

Connectable CPU unit

KV-X Series/KV-8000A

Max. number of connectable units

4

Number of ports

2

Supported camera models

KV-CA1H (Compact standard camera)
KV-CA1W (Wide-field high-resolution camera)

Cable length

5/10/20 m 16.4'/32.8'/65.6'*6

Recording time

Approx. 3 minutes*7

Internal current consumption

260 mA or less*8

Weight

Approx. 190 g

*1 for use with KV-X/KV-8000 Series
*2 Supplied via the CPU unit or expansion unit.
*3 Guaranteed range in which the system can be used.
*4 Specified according to the temperature in the control panel on the lower side of the unit.
*5 Compliant with JIS B 3502 IEC 61131-2, Scan times: 10 times in each of the X, Y, and Z directions (for 100 min.)
*6 Lengths of the KV-C5/C10/C20 camera cables.
*7 Record time for one KV-CA1H with the following configuration of settings (initial value). The actual recording time varies depending on the number of devices, the frame rate, and the image quality settings. Frame rate: 30 fps/Quality: 3
In addition, the recorded video is cleared when the power is turned off.
*8 Internal current consumption for the KV-CA02 only. Connecting a camera adds the internal current consumption of the connected camera.

Model

KV-CA02 *1

General specifications

Power voltage

System configuration using an expansion unit for KV-5000/3000 Series: 24 VDC (±10%)*2
System configuration using an expansion unit only for KV-8000/7000 Series: 24 VDC (-15%/+20%)*2

Operating ambient temperature

System configuration using an expansion unit for KV-5000/3000 Series: 0 to +50°C 32 to 122°F
(no freezing)*3*4
System configuration using an expansion unit only for KV-8000/7000 Series: 0 to +55°C 32 to 131°F
(no freezing)*3*4

Operating ambient humidity

System configuration using an expansion unit for KV-5000/3000 Series: 10 to 95% RH
(no condensation)*3
System configuration using an expansion unit only for KV-8000/7000 Series: 5 to 95% RH
(no condensation)*3

Storage ambient temperature

System configuration using an expansion unit for KV-5000/3000 Series: -20 to +70°C -4 to +158°F*3
System configuration using an expansion unit only for KV-8000/7000 Series: -25 to +75°C -13 to +167°F*3

Storage relative humidity

System configuration using an expansion unit for KV-5000/3000 Series: 10 to 95% RH
(no condensation)*3
System configuration using an expansion unit only for KV-8000/7000 Series: 5 to 95% RH
(no condensation)*3

Operating environment

No dust or corrosive gas

Operating altitude

2000 m 6561.7' or less

Noise immunity

1500 Vp-p or more
Pulse duration: 1 μs, 50 ns (based on noise simulator)
IEC standard-compliant (IEC 61000-4-2/3/4/6)

Withstand voltage

1500 VAC for one minute (between the power terminals and the I/O terminals, and between the external terminals and the case)

Insulation resistance

50 MΩ or more (between the power terminals and the I/O terminals and between the external terminals and the case, with 500 VDC megohmmeter)

Vibration resistance

Intermittent vibration

Frequency 5 to 9 Hz

Half amplitude 3.5 mm 0.14"*5

Frequency 9 to 150 Hz

Acceleration 9.8 m/s2 32.2'/s2*5

Continuous vibration

Frequency 5 to 9 Hz

Half amplitude 1.75 mm 0.07"*5

Frequency 9 to 150 Hz

Acceleration 4.9 m/s2 16.1'/s2*5

Shock resistance

Acceleration: 150 m/s2 492.1'/s2, Application time: 11 ms, 2 times in each of the X, Y, and Z directions

Pollution degree

2

Performance specifications

Connectable CPU unit

KV-X Series/KV-8000A

Max. number of connectable units

4

Number of ports

2

Supported camera models

KV-CA1H (Compact standard camera)
KV-CA1W (Wide-field high-resolution camera)

Cable length

5/10/20 m 16.4'/32.8'/65.6'*6

Recording time

Approx. 3 minutes*7

Internal current consumption

260 mA or less*8

Weight

Approx. 190 g

*1 for use with KV-X/KV-8000 Series
*2 Supplied via the CPU unit or expansion unit.
*3 Guaranteed range in which the system can be used.
*4 Specified according to the temperature in the control panel on the lower side of the unit.
*5 Compliant with JIS B 3502 IEC 61131-2, Scan times: 10 times in each of the X, Y, and Z directions (for 100 min.)
*6 Lengths of the KV-C5/C10/C20 camera cables.
*7 Record time for one KV-CA1H with the following configuration of settings (initial value). The actual recording time varies depending on the number of devices, the frame rate, and the image quality settings. Frame rate: 30 fps/Quality: 3
In addition, the recorded video is cleared when the power is turned off.
*8 Internal current consumption for the KV-CA02 only. Connecting a camera adds the internal current consumption of the connected camera.

All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.

If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.

In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.

PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.

Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.

PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.

Trusted By

"Fast service for obsolete parts"

Increasingly PLC/ HMI control platforms are becoming obsolete and parts are no longer supported, however PLC Direct had the HMI we needed and fast shipping for our system to get back online!

Buyer at GE Health

"Helping us move projects forward"

With supply chain issues increasingly affecting our business, PLC Direct has been there for us to supply the PLC products we need, when we need it. If they don't have it readily available, they find it and provide it quickly and reliably. This has helped us move forward with several projects that would have otherwise taken us many, many months to complete.

Buyer at E-Merge Systems – A Rockwell Integrator