GP-M025 Keyence

Specifications

Model

GP-M025

Rated pressure

-14.5 to +362.6 PSI
(-0.1 to +2.5 MPa)

Possible display range

-52.2 to +400.3 PSI
(-0.360 to +2.760 MPa)

Zero-cut pressure value

±0.5% of F.S.

Burst pressure

5075 PSI (35 MPa)

Display resolution

kPa

1

MPa

0.001

PSI

0.1

bar

0.01

kgf/cm2

Fluid type

Gas or liquid that will not corrode the liquid contact part

Type of pressure

Gage pressure

Precision

±1.0% of F.S. or less*1

Repeatability

±0.3% of F.S. or less*2

Temperature characteristics

±0.6% of F.S./10°C 50°F

Connection port

G3/4 (Changes to the R male 1/8, R male 1/4, R male 3/8, G female 1/4, NPT male 1/8, and NPT male 1/4 option adapters are available.)

Box rotation angle

Maximum 330°

Medium temperature

-20 to +100°C -4°F to +212°F (no freezing/condensation)*3

Power voltage

10-30 VDC, Ripple (P-P): 10% max, Class 2 or LPS

Current consumption

50 mA or less (when 24 V: 32 mA or less, when 12 V: 48 mA or less. Not including load)*4

Display method

4 column, digital LED, red/Vertical inversion display possible

Operation display light

Operation indicator (output 1) (orange), Operation indicator (output 2) (orange)

Hysteresis

During hysteresis mode: variable (Difference between switch-on point and switch-off point is hysteresis)
During window mode: fixed (0.5% of F.S.)

Response

Control output

Selectable from 3 to 5000 ms

Analog output

As above + 2 ms (90% response)

Output

Output 1 control output

NPN/PNP open collector (Selectable), Max. 250 mA (30 V max)
Main unit residual voltage 1 V max, N.O./N.C. selectable

Output 2
replacement type

Control output

Analog output

4-20 mA, maximum load resistance 500 Ω (When the electric voltage is more than 20 V)*5

Environmental resistance

Enclosure rating

IP67

Pressure resistance

10 MPa (100 bar)

Ambient temperature

-20 to +80 °C -4 to 176 °F (No freezing and no condensation)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

IEC60068-2-6 20 G (10 to 2000 Hz, 2 hours each in the X, Y, and Z axis)

Shock resistance

IEC60068-2-27 50G (11 ms, 3 times for each of X, Y and Z direction)

Material
properties

Wetted part

Pressure port: SUSXM7, Diaphragm pressure port: Al2O3 (Alumina), O ring: FKM

Other parts

Housing metal portion: SUS304, SUS303, Housing plastic portion: PPSU, Air hole: PTFE, nickel-plated brass.

Applicable cable

M12 connector 4 pin

Weight

Approx. 150 g

*1 This is the value when considering linearity + hysteresis + repeatability in a stable environment of 23°C 73°F.
*2 The repeatability, based on consistent conditions, is the variation in the value that will be displayed.
*3 When the temperature of the piping exceeds 80°C 176°F, do not connect the cable.
*4 Consumption current including output is 0.6 A and under.
*5 The maximum load resistance R will be the values below in response to the electric voltage E. When 10-23V: R = {38 x (E-10) + 128} Ω When 23-30V: R = 622 Ω

Est. delivery between and    
Estimated delivery dates are estimates only. Int'l customers allow a few more days. For more precise delivery estimates, please contact us at support@plc-direct.com. Contact us in advance for expedited shipping options.
Sale price$349.76
1-year warranty
FREE WORDWIDE SHIPPING
Condition:
$349.76
$0.00
$0.00
Ach Direct Debit American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa

Specifications

Model

GP-M025

Rated pressure

-14.5 to +362.6 PSI
(-0.1 to +2.5 MPa)

Possible display range

-52.2 to +400.3 PSI
(-0.360 to +2.760 MPa)

Zero-cut pressure value

±0.5% of F.S.

Burst pressure

5075 PSI (35 MPa)

Display resolution

kPa

1

MPa

0.001

PSI

0.1

bar

0.01

kgf/cm2

Fluid type

Gas or liquid that will not corrode the liquid contact part

Type of pressure

Gage pressure

Precision

±1.0% of F.S. or less*1

Repeatability

±0.3% of F.S. or less*2

Temperature characteristics

±0.6% of F.S./10°C 50°F

Connection port

G3/4 (Changes to the R male 1/8, R male 1/4, R male 3/8, G female 1/4, NPT male 1/8, and NPT male 1/4 option adapters are available.)

Box rotation angle

Maximum 330°

Medium temperature

-20 to +100°C -4°F to +212°F (no freezing/condensation)*3

Power voltage

10-30 VDC, Ripple (P-P): 10% max, Class 2 or LPS

Current consumption

50 mA or less (when 24 V: 32 mA or less, when 12 V: 48 mA or less. Not including load)*4

Display method

4 column, digital LED, red/Vertical inversion display possible

Operation display light

Operation indicator (output 1) (orange), Operation indicator (output 2) (orange)

Hysteresis

During hysteresis mode: variable (Difference between switch-on point and switch-off point is hysteresis)
During window mode: fixed (0.5% of F.S.)

Response

Control output

Selectable from 3 to 5000 ms

Analog output

As above + 2 ms (90% response)

Output

Output 1 control output

NPN/PNP open collector (Selectable), Max. 250 mA (30 V max)
Main unit residual voltage 1 V max, N.O./N.C. selectable

Output 2
replacement type

Control output

Analog output

4-20 mA, maximum load resistance 500 Ω (When the electric voltage is more than 20 V)*5

Environmental resistance

Enclosure rating

IP67

Pressure resistance

10 MPa (100 bar)

Ambient temperature

-20 to +80 °C -4 to 176 °F (No freezing and no condensation)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

IEC60068-2-6 20 G (10 to 2000 Hz, 2 hours each in the X, Y, and Z axis)

Shock resistance

IEC60068-2-27 50G (11 ms, 3 times for each of X, Y and Z direction)

Material
properties

Wetted part

Pressure port: SUSXM7, Diaphragm pressure port: Al2O3 (Alumina), O ring: FKM

Other parts

Housing metal portion: SUS304, SUS303, Housing plastic portion: PPSU, Air hole: PTFE, nickel-plated brass.

Applicable cable

M12 connector 4 pin

Weight

Approx. 150 g

*1 This is the value when considering linearity + hysteresis + repeatability in a stable environment of 23°C 73°F.
*2 The repeatability, based on consistent conditions, is the variation in the value that will be displayed.
*3 When the temperature of the piping exceeds 80°C 176°F, do not connect the cable.
*4 Consumption current including output is 0.6 A and under.
*5 The maximum load resistance R will be the values below in response to the electric voltage E. When 10-23V: R = {38 x (E-10) + 128} Ω When 23-30V: R = 622 Ω

Model

GP-M025

Rated pressure

-14.5 to +362.6 PSI
(-0.1 to +2.5 MPa)

Possible display range

-52.2 to +400.3 PSI
(-0.360 to +2.760 MPa)

Zero-cut pressure value

±0.5% of F.S.

Burst pressure

5075 PSI (35 MPa)

Display resolution

kPa

1

MPa

0.001

PSI

0.1

bar

0.01

kgf/cm2

Fluid type

Gas or liquid that will not corrode the liquid contact part

Type of pressure

Gage pressure

Precision

±1.0% of F.S. or less*1

Repeatability

±0.3% of F.S. or less*2

Temperature characteristics

±0.6% of F.S./10°C 50°F

Connection port

G3/4 (Changes to the R male 1/8, R male 1/4, R male 3/8, G female 1/4, NPT male 1/8, and NPT male 1/4 option adapters are available.)

Box rotation angle

Maximum 330°

Medium temperature

-20 to +100°C -4°F to +212°F (no freezing/condensation)*3

Power voltage

10-30 VDC, Ripple (P-P): 10% max, Class 2 or LPS

Current consumption

50 mA or less (when 24 V: 32 mA or less, when 12 V: 48 mA or less. Not including load)*4

Display method

4 column, digital LED, red/Vertical inversion display possible

Operation display light

Operation indicator (output 1) (orange), Operation indicator (output 2) (orange)

Hysteresis

During hysteresis mode: variable (Difference between switch-on point and switch-off point is hysteresis)
During window mode: fixed (0.5% of F.S.)

Response

Control output

Selectable from 3 to 5000 ms

Analog output

As above + 2 ms (90% response)

Output

Output 1 control output

NPN/PNP open collector (Selectable), Max. 250 mA (30 V max)
Main unit residual voltage 1 V max, N.O./N.C. selectable

Output 2
replacement type

Control output

Analog output

4-20 mA, maximum load resistance 500 Ω (When the electric voltage is more than 20 V)*5

Environmental resistance

Enclosure rating

IP67

Pressure resistance

10 MPa (100 bar)

Ambient temperature

-20 to +80 °C -4 to 176 °F (No freezing and no condensation)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

IEC60068-2-6 20 G (10 to 2000 Hz, 2 hours each in the X, Y, and Z axis)

Shock resistance

IEC60068-2-27 50G (11 ms, 3 times for each of X, Y and Z direction)

Material
properties

Wetted part

Pressure port: SUSXM7, Diaphragm pressure port: Al2O3 (Alumina), O ring: FKM

Other parts

Housing metal portion: SUS304, SUS303, Housing plastic portion: PPSU, Air hole: PTFE, nickel-plated brass.

Applicable cable

M12 connector 4 pin

Weight

Approx. 150 g

*1 This is the value when considering linearity + hysteresis + repeatability in a stable environment of 23°C 73°F.
*2 The repeatability, based on consistent conditions, is the variation in the value that will be displayed.
*3 When the temperature of the piping exceeds 80°C 176°F, do not connect the cable.
*4 Consumption current including output is 0.6 A and under.
*5 The maximum load resistance R will be the values below in response to the electric voltage E. When 10-23V: R = {38 x (E-10) + 128} Ω When 23-30V: R = 622 Ω

All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.

If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.

In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.

PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.

Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.

PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.

Trusted By

"Fast service for obsolete parts"

Increasingly PLC/ HMI control platforms are becoming obsolete and parts are no longer supported, however PLC Direct had the HMI we needed and fast shipping for our system to get back online!

Buyer at GE Health

"Helping us move projects forward"

With supply chain issues increasingly affecting our business, PLC Direct has been there for us to supply the PLC products we need, when we need it. If they don't have it readily available, they find it and provide it quickly and reliably. This has helped us move forward with several projects that would have otherwise taken us many, many months to complete.

Buyer at E-Merge Systems – A Rockwell Integrator