Specifications
Model |
CA-LH50P |
|||
Focal point |
50 mm 1.97" |
|||
F-stop range (aperture) |
F2.8/4/8/16*1 |
|||
Minimum WD |
0.2 m 0.7' |
|||
Filter size |
27.0 mm 1.06" P0.5 |
|||
Mount |
C-mount |
|||
Max. compatible image sensor size |
2/3" |
|||
Resolving power |
100 cycles/mm at center, 80 cycles/mm on periphery |
|||
TV distortion |
-0.03% |
|||
Enclosure rating |
IP64 (objective lens, water repellent coating specifications)*3 |
|||
Ambient temperature/humidity range |
0 to +50°C 32 to 122°F, 80% RH or less (No condensation) |
|||
Weight |
Approx. 85 g |
|||
*1 The f-stop (aperture) is changed by replacing the diaphragm plate. When this product is shipped, the OPEN diaphragm plate is attached to the lens, so replace it with one of the other included diaphragm plates (F4, F8, or F16) as necessary. To use the f-stop (aperture) in the OPEN mode, use the lens without removing the OPEN aperture. | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
SV2-C10CG |
|||
Type |
Motor power cable, Hi-flex robotic cable |
|||
Length |
10 m 32.8' |
|||
Note |
for 750 W motor |
|||

Specifications
Model |
EH-416 |
|||
Type |
Standard , Non-shielded , Cylindrical and threaded |
|||
Detectable object |
Ferrous metals (see Characteristics for nonferrous metals) |
|||
Standard target (iron, t=1 mm 0.04") |
20 x 20 mm 0.79" x 0.79" |
|||
Stable detecting range |
0 to 6 mm0.24" |
|||
Maximum detecting distance |
13 mm0.51" |
|||
Hysteresis |
0.05 mm0.002" |
|||
Repeatability |
0.012 mm0.0005" |
|||
Temperature characteristics |
±10% max. of detecting distance at 23°C 73.4°F, within -10 to +60°C 14 to 140°F |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Ambient temperature |
-10 to +60 °C 14 to 140 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Weight |
Approx. 72 g (including nuts and 3-m 9.8' cable) |
|||


Specifications
Model |
OP-51625 |
|||
Overview |
Bottom-mounting bracket for the MS2-H50. This is used when directly fastening the main unit with screws. |
|||
Applicable product |
MS2-H50 |
|||
Weight |
Approx. 79 g |
|||

Specifications
Model |
ER-GM12P03C |
|||
Type |
General-purpose all-metal shielded type Screw type M12 Connector with pigtail (M12 4-pin) PNP output Mid-Range |
|||
Power supply cable length |
0.3 m 1.0' *1 |
|||
No. of control outputs |
2 |
|||
Output mode |
Output 1 |
N.O. |
||
Output 2 |
N.C. |
|||
Button |
None |
|||
Button |
Function |
― |
||
Detecting distance |
4 mm 0.16" ±10% *2 |
|||
Response frequency |
150 Hz *3 *4 |
|||
Hysteresis distance |
15% or less of detecting distance |
|||
Detectable object |
Magnetic metal, Non-magnetic metal *5 |
|||
Standard detectable object (Iron, t = 1 mm 0.04") |
12 × 12 mm 0.47" × 0.47" |
|||
Temperature characteristics |
±10% or less of detecting distance at +25°C +77°F (-25 to +55°C -13°F to +131°F) |
|||
Control output |
Open-collector, 30 VDC or less; 50 mA or less for 1 output; 50 mA or less in total for 2 outputs |
|||
Control output |
Residual voltage |
PNP output: 2.2 V or less (Output current: 10 mA or less) / 2.3 V or less (Output current: 10 to 50 mA) *6 |
||
Power supply |
Power voltage |
16 to 30 VDC (including 10% or less ripple (P-P)), Class 2 |
||
Power consumption (excluding load current) |
1000 mW or less (42 mA or less at 24 V, 63 mA or less at 16 V) |
|||
Protection circuit |
Protection against reverse power connections, output short-circuits, and reverse output connections |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529), IP67G (JIS C 0920) |
||
Ambient temperature |
-25 to +70°C -13°F to +158°F (no freezing) *7 |
|||
Relative humidity |
Up to 95% RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions |
|||
Shock resistance |
1000 m/s2 3280.8 ft/s2 (100 G), |
|||
Material |
Detecting surface: SUS303, Mounting screw: SUS303, Case resin: PBT, Nut: SUS304, Toothed lock washer: SUS304 |
|||
Accessories |
Nut ×2, Toothed lock washer ×1 |
|||
Weight |
Approx. 50 g 1.77 oz |
|||
*1 Ensure the power cable is no longer than 30 m 98.4' for connector and connector with pigtail types. | ||||

Specifications
Model |
OP-91127 |
|||
Type |
Mounting Fittings |
|||
Overview |
Dedicated mounting bracket for PQ. Transmitter/receiver setup. |
|||
Applicable product |
PQ-01, PQ-02 |
|||
Number included |
2 pcs. |
|||
Material |
Steel (Black chromate) |
|||


Specifications
Model |
CL-V020G |
|||
Type |
Optical unit |
|||
Head |
CL-V020 *1 |
|||
Reference distance |
20 mm 0.79" |
|||
Reference measurement range |
Measurement range |
±1.3 mm ±0.05" |
||
Linearity |
±0.3 μm ±0.000012" *2 |
|||
High precision measurement range |
Measurement range |
±0.5 mm ±0.02" |
||
Linearity |
±0.23 μm ±0.000009" *2 |
|||
Resolution |
0.01 μm *3 |
|||
Spot diameter |
ø20 μm ø0.0008" |
|||
Laser class |
Optical unit |
Class I |
||
Sampling cycle |
100/200/500/1000 μs (Adjustable 4-stage) |
|||
Environmental resistance |
Enclosure rating |
Head |
IP40 degassed structure for vacuum environments *4 |
|
Ambient light |
Target surface illuminance: 30000 lux (Incandescent lamp) |
|||
Operating ambient temperature |
Head |
-20 to 200°C -4 to 392°F |
||
Optical unit |
0 to 50°C 32 to 122°F |
|||
Relative humidity |
85% RH or less (no condensation) |
|||
Vibration resistance |
Head |
10 to 57 Hz, double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axes |
||
Optical unit |
10 to 57 Hz, double amplitude 0.3 mm 0.01"; 2 hours each for X, Y, and Z axes |
|||
Shock resistance |
15 G, 6 ms |
|||
Vacuum |
Ultra-high-vacuum environments *5 |
|||
Explosion-proof |
performance |
Head |
None |
|
Optical unit | ||||
Zone/Division |
Head |
|||
Optical unit | ||||
Ambient temperature |
Head |
|||
Optical unit | ||||
Certification number | ||||
Temperature characteristic |
Head |
0.013% of F.S./°C *6 |
||
Optical unit |
0.015% of F.S./°C |
|||
Material |
Head |
SUS304 |
||
Optical unit |
Polycarbonate |
|||
Weight |
Head |
Approx. 100 g 3.53 oz |
||
Optical unit |
Approx. 1600 g 3.53 lb |
|||
*1 Sensor head and optical unit are a matched pair. Not cross compatible. | ||||

Specifications
Model |
OP-87667 |
|||
Type |
Plate nut for flat |
|||
Applicable product |
PR-F Series |
|||
Number included |
2 pcs. |
|||
Material |
SUS316L |
|||
Weight |
Approx. 1 g |
|||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
FU-32*1 |
|||
Optical axis diameter |
ø0.6 mm0.024" |
|||
Beam emitting direction |
Side |
|||
Fibre unit length |
1 m39.37" free-cut |
|||
Fibre unit diameter |
ø1.3 |
|||
Minimum bend radius |
R25 mm0.984" |
|||
Minimum detectable object |
Gold wire with a diameter of 0.005 mm0.0002" *2 |
|||
Environmental resistance |
Ambient temperature |
-40 to +70 °C -40 to 158 °F |
||
Weight |
Approx. 5 g |
|||
*1 For details on the detecting distance, see the fiber amplifier catalog. | ||||

Specifications
Model |
S-P12 |
|||
Type |
Tough mounting bracket |
|||
Applicable product |
PZ2 Series |
|||
Number included |
1 unit |
|||

Specifications
Model |
GL-VP2 |
|||
Type |
Main unit connection cable |
|||
Number included |
1 pc. |
|||
Cable end |
Female side: M12 connector 5 pin |
|||
Number of cores |
5 |
|||
Length |
2 m 6.6' |
|||
Material |
connector: PVC/Nickel-plated brass |
|||
Weight |
130 g |
|||

Specifications
Model |
DL-EC1A |
|||
Ethernet |
Compliant standards |
IEEE802.3u (100BASE-TX) |
||
Transmission speed |
100 Mbps (100BASE-TX) |
|||
Transmission interface |
Category 5e or higher STP cable |
|||
Distance between |
100 m 3937.01' |
|||
Communication port |
RJ-45 x 2 |
|||
EtherCAT |
Compatible functions |
Process data object communication (cyclic communication) |
||
Conformance test |
Complies with V2.0.42 |
|||
Sensor |
Connectable |
Sensor amplifiers with D-bus support*1 |
||
Number of |
15 units max.*2 |
|||
Indicator lamps |
Power indicator (PWR): Green LED |
|||
Power voltage |
20 to 30 VDC, including ripple (p-p) of 10 % |
|||
Power consumption |
2,100 mW or less (at 30 V, 70 mA max.) |
|||
Environmental resistance |
Pollution degree |
2 |
||
Ambient temperature |
-20 to +55 °C -4 to 131 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Material |
Main unit: Polycarbonate |
|||
Weight |
Approx. 70 g (including connectors) |
|||
*1 D-bus is the name of KEYENCE's wiring-saving system for sensor amplifiers. | ||||

Specifications
Model |
GL-VM06LN |
|||
Beam axis spacing/Lens diameter |
40 mm 1.57": ø5 ø0.197" |
|||
Number of beam axes |
6 |
|||
Total length |
240 mm 9.45" |
|||
Detection height |
200 mm 7.87" |
|||
Protection height |
285 mm 11.22" |
|||
Minimum detectable object size |
ø45 mm ø1.77" *1 |
|||
Detecting distance |
0.3 to 15 m 1.0' to 49.2' *2 |
|||
Effective angular aperture |
Up to ±2.5° (3 m 9.8' or above) |
|||
Light source |
Infrared LED (850 nm) |
|||
Detection mode |
ON when all beam axes received |
|||
Synchronization method |
Optical synchronization |
|||
Interference prevention function |
Interference prevention up to 2 units by series connection and switch setting |
|||
Control output (OSSD output) |
Output type |
Transistor output ×2 (PNP/NPN) |
||
Maximum load current |
150 mA or less |
|||
Residual voltage (when ON) |
Up to 2.5 V (with 5 m 16.4' cable) |
|||
OFF voltage |
Up to 2.0 V (with 5 m 16.4' cable) |
|||
Leakage current |
Up to 0.8 mA |
|||
Maximum load capacity |
0.8 μF |
|||
Load wiring resistance |
Up to 2.5Ω |
|||
Protection circuit |
Power supply reverse connection protection, short circuit protection for each output, surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC/EN61496-1, UL61496-1 |
|
EMI |
EN55011 Class A, FCC Part15B Class A, ICES-003 Class A |
|||
Safety |
IEC61496-1/EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Response time (OSSD) |
With channel 0 |
ON→OFF |
4.1 |
|
OFF→ON |
45.7 *3 |
|||
All blocked→ON |
51.2 *4 |
|||
With channel A or B |
ON→OFF |
10.0 |
||
OFF→ON |
54.9 *3 |
|||
All blocked→ON |
68.2 *4 |
|||
Inputs |
Short circuit current: Approx. 3 mA |
|||
Power supply |
Power voltage |
24 VDC -20/+25% 10% ripple (P-P) or less, class 2 |
||
Current consumption (at maximum) (mA) Indicator : Standard / Eco/ External control |
Transmitter |
60 *5 |
||
Receiver |
73 *5 |
|||
Current consumption (at maximum) (mA) Indicator : OFF |
Transmitter |
48 *5 |
||
Receiver |
56 *5 |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Ambient light |
Incandescent lamp: 3000 lux or less, sunlight: 20,000 lux or less |
|||
Operating ambient temperature |
-30 to +55°C -22 to +131°F (no freezing) *6 |
|||
Operating relative humidity |
Up to 95%RH (no condensation) |
|||
Storage temperature |
-30 to +70°C -22 to +158°F (no freezing) |
|||
Storage relative humidity |
Up to 95% RH |
|||
Overvoltage category |
ll |
|||
Vibration resistance |
5 to 150 Hz 1G 10 cycles each in X, Y, and Z axes |
|||
Shock resistance |
15 G 6 ms pulses 100 times each in X, Y, and Z axes |
|||
Material |
Main unit case |
Aluminum alloy |
||
Upper case/lower case |
PPS (GF40%) |
|||
Front cover |
Polycarbonate, SUS304 |
|||
Weight |
Transmitter |
170 g 6.00 oz |
||
Receiver | ||||
Total |
340 g 12.00 oz |
|||
*1 The maximum operating speed of the detected object is 2.0 m 6.6'/s. | ||||

Specifications
Model |
CA-DQR15 |
|||
Type |
Square Lights (Direct) |
|||
LED color |
red |
|||
Diffusion plate |
OP-87042*1 |
|||
Power consumption |
14.4 W*2 |
|||
Weight |
Approx 520 g |
|||
*1 The models listed on the left are for a single bar. Four sets are required for the whole square. | ||||

Specifications
Model |
GL-R08L |
|||
Detection capability |
ø1.77" ø45 mm |
|||
Total length |
12.60" 320mm |
|||
No. of beam |
8 |
|||
Detection height |
11.02" 280mm |
|||
Protection height |
14.37" 365mm |
|||
Beam axis spacing/Lens diameter |
40 mm / ø5 1.57" / ø0.20" |
|||
Detecting distance |
0.66 to 49.21' 0.2 to 15 m*1 |
|||
Effective aperture angle |
Max. ±2.5° (When operating distance is 9.84' 3 m or more) |
|||
Light source |
Infrared LED (870 nm) |
|||
Response time (OSSD) (ms) |
Wire synchronization, One-line or |
ON→OFF |
6.6 |
|
OFF→ON |
48.7*2 |
|||
All blocked→ON |
63.1*3 |
|||
Optical synchronization system |
ON→OFF |
6.9 |
||
OFF→ON |
49.1*2 |
|||
All blocked→ON |
64.2*3 |
|||
Detection mode |
Turns on when no interruptions are present in the detection zone |
|||
Synchronization between the transmitter and receiver |
Optical synchronization or Wire synchronization (Determined by wiring) |
|||
Light interference prevention function |
Prevents mutual interference in up to two GL-R systems. |
|||
Control output |
Output |
2 transistor outputs. (PNP or NPN is determined by the cable type) |
||
Max. load current |
500 mA*4 |
|||
Residual voltage (during ON) |
Max. 2.5 V (with a cable length of 16.40' 5 m) |
|||
OFF state voltage |
Max. 2.0 V (with a cable length of 16.40' 5 m) |
|||
Leakage current |
Max. 200 µA |
|||
Max. capacitive load |
2.2 µF |
|||
Load wiring resistance |
Max. 2.5 Ω |
|||
Supplemental output |
AUX |
transistor outputs. (PNP or NPN is determined by the cable type) |
||
Error output | ||||
Muting lamp output |
Incandescent lamp (24 VDC, 1 to 5.5 W) |
|||
External input |
When using a PNP output cable |
EDM input |
ON voltage: 10 to 30 V |
|
When using an NPN output cable |
ON voltage: 0 to 3 V |
|||
Power supply |
Power voltage |
24 VDC ±20%, ripple (P-P) 10% or less, Class 2 |
||
Current |
Transmitter |
41 |
||
Receiver |
68 |
|||
Protection circuit |
Reverse current protection, short-circuit protection for each output, surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC61496-1, EN61496-1, UL61496-1 |
|
EMI |
EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA |
|||
Safety |
IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Overvoltage category |
II |
|||
Ambient light |
Incandescent lamp: 3,000 lux or less., Sunlight: 20,000 lux or less |
|||
Operating ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) |
|||
Operating relative humidity |
15 to 85 % RH (No condensation) |
|||
Storage temperature |
-25 to +60 °C -13 to 140 °F (No freezing) |
|||
Storage relative humidity |
15 to 95 % RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions |
|||
Shock resistance |
100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions |
|||
Material |
Main unit case |
Aluminum |
||
Upper case/lower case |
Nylon (GF 30%) |
|||
Front cover |
Polycarbonate, SUS304 |
|||
Weight |
Transmitter |
430 g |
||
Receiver |
440 g |
|||
*1 When the option front protection cover is installed on the one of transmitter or receiver, the Operating distance is shorten by 1.64' 0.5 m. When the front covers are installed on both of the transmitter and receiver, the Operating distance is shorten by 3.28' 1.0 m. | ||||


Specifications
Model |
GL-VM191FP |
|||
Beam axis spacing/Lens diameter |
10 mm 0.39": ø4 ø0.16" |
|||
Number of beam axes |
191 |
|||
Total length |
1920 mm 75.59" |
|||
Detection height |
1900 mm 74.80" |
|||
Protection height |
1924 mm 75.75" |
|||
Minimum detectable object size |
ø14 mm ø0.55" *1 |
|||
Detecting distance |
0.3 to 12 m 1.0' to 39.4' *2 |
|||
Effective angular aperture |
Up to ±2.5° (3 m 9.8' or above) |
|||
Light source |
Infrared LED (850 nm) |
|||
Detection mode |
ON when all beam axes received |
|||
Synchronization method |
Optical synchronization |
|||
Interference prevention function |
Interference prevention up to 2 units by series connection and switch setting |
|||
Control output (OSSD output) |
Output type |
Transistor output ×2 (PNP/NPN) |
||
Maximum load current |
150 mA or less |
|||
Residual voltage (when ON) |
Up to 2.5 V (with 5 m 16.4' cable) |
|||
OFF voltage |
Up to 2.0 V (with 5 m 16.4' cable) |
|||
Leakage current |
Up to 0.8 mA |
|||
Maximum load capacity |
0.8 μF |
|||
Load wiring resistance |
Up to 2.5Ω |
|||
Protection circuit |
Power supply reverse connection protection, short circuit protection for each output, surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC/EN61496-1, UL61496-1 |
|
EMI |
EN55011 Class A, FCC Part15B Class A, ICES-003 Class A |
|||
Safety |
IEC61496-1/EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Response time (OSSD) |
With channel 0 |
ON→OFF |
11.9 |
|
OFF→ON |
61.3 *3 |
|||
All blocked→ON |
78.4 *4 |
|||
With channel A or B |
ON→OFF |
41.1 |
||
OFF→ON |
118.8 *3 |
|||
All blocked→ON |
178.6 *4 |
|||
Inputs |
Short circuit current: Approx. 3 mA |
|||
Power supply |
Power voltage |
24 VDC -20/+25% 10% ripple (P-P) or less, class 2 |
||
Current consumption (at maximum) (mA) Indicator : Standard / Eco/ External control |
Transmitter |
187 *5 |
||
Receiver |
213 *5 |
|||
Current consumption (at maximum) (mA) Indicator : OFF |
Transmitter |
66 *5 |
||
Receiver |
80 *5 |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Ambient light |
Incandescent lamp: 3000 lux or less, sunlight: 20,000 lux or less |
|||
Operating ambient temperature |
-30 to +55°C -22 to +131°F (no freezing) *6 |
|||
Operating relative humidity |
Up to 95%RH (no condensation) |
|||
Storage temperature |
-30 to +70°C -22 to +158°F (no freezing) |
|||
Storage relative humidity |
Up to 95% RH |
|||
Overvoltage category |
ll |
|||
Vibration resistance |
5 to 150 Hz 1G 10 cycles each in X, Y, and Z axes |
|||
Shock resistance |
15 G 6 ms pulses 100 times each in X, Y, and Z axes |
|||
Material |
Main unit case |
Aluminum alloy |
||
Upper case/lower case |
PPS (GF40%) |
|||
Front cover |
Polycarbonate, SUS304 |
|||
Weight |
Transmitter |
1250 g 44.12 oz |
||
Receiver |
1260 g 44.47 oz |
|||
Total |
2510 g 88.60 oz |
|||
*1 The maximum operating speed of the detected object is 2.0 m 6.6'/s. | ||||

Specifications
Model |
CL-P030G |
|||
Type |
Optical unit |
|||
Head |
CL-P030 *1 |
|||
Reference distance |
30 mm 1.18" |
|||
Reference measurement range |
Measurement range |
±3.7 mm ±0.15" |
||
Linearity |
±0.81 μm ±0.000032" *2 |
|||
High precision measurement range |
Measurement range |
±1.0 mm ±0.04" |
||
Linearity |
±0.59 μm ±0.000023" *2 |
|||
Resolution |
0.015 μm 0.000001" *3 |
|||
Spot diameter |
ø38 μm ø0.0015" |
|||
Laser class |
Optical unit |
Class I |
||
Sampling cycle |
100/200/500/1000 μs (Adjustable 4-stage) |
|||
Environmental resistance |
Enclosure rating |
Head |
IP67 (IEC60529) |
|
Ambient light |
Target surface illuminance: 30000 lux (Incandescent lamp) |
|||
Ambient temperature |
0 to 50°C 32 to 122°F |
|||
Relative humidity |
85% RH or less (no condensation) |
|||
Vibration resistance |
Head |
10 to 57 Hz, double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axes |
||
Optical unit |
10 to 57 Hz, double amplitude 0.3 mm 0.01"; 2 hours each for X, Y, and Z axes |
|||
Shock resistance |
15 G, 6 ms |
|||
Temperature characteristic |
Head |
0.005% of F.S./°C |
||
Optical unit |
0.015% of F.S./°C |
|||
Material |
Head |
Front: SUS, Rear: Aluminum |
||
Optical unit |
Polycarbonate |
|||
Weight |
Head |
Approx. 200 g 7.06 oz |
||
Optical unit |
Approx. 1600 g 3.53 lb |
|||