PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
SJ-M071C |
|||
Type |
Head |
|||
Voltage application method |
Pulse AC method |
|||
Applied voltage |
±5.5 kV |
|||
Rated output voltage |
±6 kV |
|||
Ion balance control method |
I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Control input |
Static elimination stop input |
Non-voltage input |
||
Control output |
Alarm output |
NPN open collector 100 mA (40 V or less) |
||
Ion level alarm output | ||||
Condition alarm output | ||||
Air purge supplied pressure |
0.2 MPa or less |
|||
Effective length |
324 mm 12.756"*2 |
|||
Total length |
380 mm 14.961"*3 |
|||
Rating |
Power voltage |
24 VDC ±10 % |
||
Current consumption |
450 mA or less |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||
Relative humidity |
35 to 65 % RH (No condensation) |
|||
Weight |
Approx. 720 g |
|||
*1 Operating distance: 50 mm 1.96" (50 Hz), 600 mm 23.62" (8 Hz), 1,500 mm 59.05" (1 Hz). Downward air flow: 0.3 m/s. Air purge: None | ||||

Specifications
Model |
CA-DZB30 |
|||
LED color |
blue |
|||
Power consumption |
28.4 W*1 |
|||
Weight |
Approx 880 g |
|||
*1 The power consumption exceeds 20 W, so the CD-DC100 cannot be used. | ||||

Specifications
Model |
LV-B302 |
|||
Type |
Mounting Bracket for Landscape Orientation |
|||
Applicable product |
LV-NH300/H300 |
|||

Specifications
Model |
OP-88896 |
|||
Female |
M12 8pin L-shape |
|||
Male |
Strand wire |
|||
Length |
2 m 6.6' |
|||
Material |
cable: PVC |
|||

Specifications
Model |
SJ-E228H |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 V |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Installation distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector, Maximum 100 mA (40 VDC or less) |
||
Condition alarm output | ||||
Alarm output | ||||
Communication function |
Remote control communication |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc 1/8 |
|||
Air supply pressure |
0.1 MPa to 0.5 MPa*2 |
|||
Effective length |
2340 mm 92.13"*3 |
|||
Total length |
2240 mm 88.19" |
|||
No. ofelectrodes |
73 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
35 to 85% RH (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
2350 g 82.89oz |
|||
*1 Measured under the following conditions. | ||||


Specifications
Model |
FS-N42P |
|||
Type |
Cable |
|||
Output |
PNP |
|||
Main unit/expansion unit |
Expansion unit |
|||
Response time |
23 µs (S-HSPD*1) /50 µs (HSPD*2) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA) /64 ms (TERA) |
|||
Number of control outputs |
1 |
|||
Number of external inputs |
― |
|||
Light source LED |
Transmitter side: Red, four-element LED (wavelength: 660 nm) |
|||
Control output |
Open-collector, 30 V or less 100 mA or less per output, |
|||
External input |
Input time: 2 ms (ON) /20 ms (OFF) or longer*3 |
|||
Unit expansion |
Up to 16 units (17 units connected in total including the main unit) . However, each dual output type will be treated as two expansion units. |
|||
Protection circuit |
Protection against reverse power connection, output overcurrent, output surge, and reverse output connection |
|||
Mutual interference prevention |
S-HSPD/HSPD: 0 units, FINE: 4 units, TURBO/SUPER/ULTRA/MEGA/TERA: 8 units (The mutual interference prevention values are twice those shown here when Double is set.) |
|||
Power supply |
Power voltage |
10 to 30 VDC (including 10 % ripple (P-P) or less) , class 2 or LPS*4 |
||
Power consumption |
During normal operation: 910 mW or less (36 mA or less at 24 V/65 mA or less at 12 V) |
|||
Environmental resistance |
Ambient light |
Incandescent lamp: 20,000 lx or less, sunlight: 30,000 lx or less |
||
Ambient temperature |
-20 °C -4 °F to +55 °C +131 °F (no freezing)*6 |
|||
Vibration resistance |
10 to 55 Hz; double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axes |
|||
Shock resistance |
500 m/s2; 3 times each for X, Y, and Z axes |
|||
Case material |
Main unit and cover: polycarbonate |
|||
Weight |
Approx. 48 g |
|||
*1 Restrictions when S-HSPD is selected | ||||


Specifications
Model |
SV2-D3BG |
|||
Type |
Motor power cable, Hi-flex robotic cable with electromagnetic brake |
|||
Length |
3 m 9.8' |
|||
Note |
for 200 W / 400 W motor |
|||

Specifications
Model |
GL-VM24HP |
|||
Beam axis spacing/Lens diameter |
20 mm 0.79": ø5 ø0.197" |
|||
Number of beam axes |
24 |
|||
Total length |
480 mm 18.90" |
|||
Detection height |
460 mm 18.11" |
|||
Protection height |
505 mm 19.88" |
|||
Minimum detectable object size |
ø25 mm ø0.98" *1 |
|||
Detecting distance |
0.3 to 15 m 1.0' to 49.2' *2 |
|||
Effective angular aperture |
Up to ±2.5° (3 m 9.8' or above) |
|||
Light source |
Infrared LED (850 nm) |
|||
Detection mode |
ON when all beam axes received |
|||
Synchronization method |
Optical synchronization |
|||
Interference prevention function |
Interference prevention up to 2 units by series connection and switch setting |
|||
Control output (OSSD output) |
Output type |
Transistor output ×2 (PNP/NPN) |
||
Maximum load current |
150 mA or less |
|||
Residual voltage (when ON) |
Up to 2.5 V (with 5 m 16.4' cable) |
|||
OFF voltage |
Up to 2.0 V (with 5 m 16.4' cable) |
|||
Leakage current |
Up to 0.8 mA |
|||
Maximum load capacity |
0.8 μF |
|||
Load wiring resistance |
Up to 2.5Ω |
|||
Protection circuit |
Power supply reverse connection protection, short circuit protection for each output, surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC/EN61496-1, UL61496-1 |
|
EMI |
EN55011 Class A, FCC Part15B Class A, ICES-003 Class A |
|||
Safety |
IEC61496-1/EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Response time (OSSD) |
With channel 0 |
ON→OFF |
4.8 |
|
OFF→ON |
46.7 *3 |
|||
All blocked→ON |
53.2 *4 |
|||
With channel A or B |
ON→OFF |
13.0 |
||
OFF→ON |
63.2 *3 |
|||
All blocked→ON |
80.9 *4 |
|||
Inputs |
Short circuit current: Approx. 3 mA |
|||
Power supply |
Power voltage |
24 VDC -20/+25% 10% ripple (P-P) or less, class 2 |
||
Current consumption (at maximum) (mA) Indicator : Standard / Eco/ External control |
Transmitter |
81 *5 |
||
Receiver |
92 *5 |
|||
Current consumption (at maximum) (mA) Indicator : OFF |
Transmitter |
52 *5 |
||
Receiver |
58 *5 |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Ambient light |
Incandescent lamp: 3000 lux or less, sunlight: 20,000 lux or less |
|||
Operating ambient temperature |
-30 to +55°C -22 to +131°F (no freezing) *6 |
|||
Operating relative humidity |
Up to 95%RH (no condensation) |
|||
Storage temperature |
-30 to +70°C -22 to +158°F (no freezing) |
|||
Storage relative humidity |
Up to 95% RH |
|||
Overvoltage category |
ll |
|||
Vibration resistance |
5 to 150 Hz 1G 10 cycles each in X, Y, and Z axes |
|||
Shock resistance |
15 G 6 ms pulses 100 times each in X, Y, and Z axes |
|||
Material |
Main unit case |
Aluminum alloy |
||
Upper case/lower case |
PPS (GF40%) |
|||
Front cover |
Polycarbonate, SUS304 |
|||
Weight |
Transmitter |
320 g 11.29 oz |
||
Receiver | ||||
Total |
640 g 22.59 oz |
|||
*1 The maximum operating speed of the detected object is 2.0 m 6.6'/s. | ||||