Sensors & Detection

25001 products

Showing 73 - 96 of 25001 products

Showing 73 - 96 of 25001 products
View
R7M-A40030-S1 Omron
Omron R7M-A40030-S1 Omron
Sale price $4,544.00
Only 6 units left

AC Motor Servomotor, 3000 RPM, 400W, Incremental, 230VAC

Keyence New Stock Image
Keyence LV-N11P Keyence
Sale price $293.70
Only 9 units left

Specifications

Model

LV-N11P

Type

2 output

Output

PNP

Cable/connector

Cable

Main/Expansion unit

Main unit

I/O

Control outputs

2 output

External input

1 input

Monitor output

None

Output selection

LIGHT-ON/DARK-ON (switch-selectable)

Timer function

Timer OFF/OFF-delay timer/ON-delay timer/One-shot timer,
Timer duration selectable: 1 ms to 9,999 ms,
Maximum error against the setting value: ±10% max.

Control outputs

PNP open collector 30 V, Residual voltage 1.2 V or less (Output current: 10 mA or less) / 2.2 V or less (Output current: 10 to 100 mA)
(Stand-alone) 1 output max: 100 mA or less, 2 output total: 100 mA or less
(Multiple connections) 1 output max: 20 mA or less

Response time

80 µs (HIGH SPEED)/250 µs (FINE)/500 µs (TURBO)/1 ms (SUPER)/4 ms (ULTRA)/16 ms (MEGA) *1

Monitor output

-

External input

Input time 2 ms (ON)/20 ms (OFF) or more*2

Number of interference
prevention units

Connected to other than LV-S31: 0 for HIGH SPEED; 2 for FINE/TURBO/SUPER; 4 for ULTRA/MEGA,
Connected to LV-S31: 2 for FINE; 4 for TURBO/SUPER/ULTRA/MEGA*3

Case size

H 32.6 mm 1.28" × W 9.8 mm 0.39" × L 78.7 mm 3.1"

Unit expansion

Up to 17 units can be connected in total (two-output type is treated as two units)

Protection circuit

Reverse polarity protection, Over-current protection, Surge absorber

Rating

Power voltage

24 VDC (operating voltage 10 to 30 VDC (with ripple)), Ripple (P-P) 10 % or less, Class 2 or LPS*4*5

Power
consumption

Normal: 950 mW or less (at 30 V. 33 mA at 24 V, 60 mA or less at 12 V)*6
Eco on mode: 815 mW or less (at 30 V. 29 mA at 24 V, 52 mA or less at 12 V)*6
Eco Full mode: 650 mW or less (at 30 V. 24 mA at 24 V, 40 mA or less at 12 V)
*7

Environmental resistance

Ambient temperature

-20 to +55 °C -4 to 131 °F (No freezing)*8

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

500 m/s2, 3 times in each of the X, Y, and Z directions

Material

Cable

PVC

Case

Main unit and cover material: Polycarbonate

Weight

Approx. 75 g

*1 80 µs cannot be selected when the LV-S31/S62/S63 is connected
*2 Input time is 25 ms (ON)/25 ms (OFF) when external calibration time is selected.
*3 These numbers double when "DOUBLE" is selected.
*4 Use with the over current protection device which is rated 30 V or more and not more than 1 A.
*5 To connect more than 9 units, the power voltage must be 20 V or more.
*6 Increases 30 mW (1 mA) for HIGH SPEED mode.
*7 It increases by 15% when connected to the LV-NH100/NH110/NH300. It does not include the power consumption of the load.
Power consumption when expansion units are connected is the total power consumption of each amplifier unit. Example: When one main unit (LV-N11N) is connected to 2 expansion units (LV-N12N) and they are used with LV-NH100 heads in HIGH SPEED mode.
(1.15 × 860 mW × 1) + (1.15 × 860 mW × 2) = 2967 mW max.
*8 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less for a unit.
One or two more units connected: -20 to +55 °C -4 to 131 °F; 3 to 10 more units connected: -20 to +50 °C -4 to 122 °F; 11 to 16 more units connected: -20 to +45 °C -4 to 113 °F. When using 2-outputs, one unit is counted as two units.

LK-G5001 Keyence
Keyence LK-G5001 Keyence
Sale price $1,872.36
Only 10 units left

Specifications

Model

LK-G5001

Type

Separate type Main controller

Sensor head compatibility

Compatible

No. of connectable sensor heads

2

Display

Minimum display unit

0.001 µm

Display range

±999.999 µm to ±9999.99 mm (7 settings selectable)

Display cycle

Approx 10 times/sec.

Display interface

Display port

Either the display unit (LK-HD500) or dedicated touch panel (LK-HD1001) can be connected

LED indicator

LASER ON

Terminal block

Analog output voltage

±10 V output, Output impedance: 100 Ω*1

Analog current output

4 to 20 mA, Maximum load resistance: 350 Ω*1

No. of analog outputs

2*1

TIMING 1 input

Non-voltage input*2

RESET 1 input

Auto-zero 1 input

Laser remote input

Non-voltage input*1

Alarm output

NPN open-collector output*1

General comparator output

Expansion connector

TIMING input

Non-voltage input*1

RESET input

Auto-zero input

Program switching input

Binary selection input

Alarm output

NPN open-collector output*1

Comparator output

Binary output

RS-232C interface

Baud rate: 9600 to 115200 bps
Data length: 8 bits Stop bit length: 1 bit Parity: None/even/odd

USB interface

USB 2.0 Hi-Speed compliant*3

Ethernet interface

100Base-TX/10Base-T*4

EtherNet/IP™interface

Cyclic communication (implicit messaging)
Message communication (explicit messaging) : UCMM and Class3 Number of connections: 32 Complies with conformance test version CT14*5

PLC-Link

The following PLCs are supported:Mitsubishi Electric: MELSEC iQ-R Series, iQ-F Series, Q Series, L Series, FX Series
EtherNet/IP™, CC-Link, and DeviceNet® cannot be used in conjunction with PLC-Link

Head expansion unit connector

Up to 10 head expansion units can be connected to one main controller

Expansion unit connector

Either of the CC-Link unit (LK-CC100) or DeviceNet® unit (LK-DN100) can be connected

Power supply

Power supply voltage

24 VDC ±10%

Maximum current consumption

0.6 A or less with 1 head/3.5 A or less with 12 heads

Environmental resistance

Ambient temperature

When one or less head expansion unit is connected: 0 to +50 °C 32 to 122 °F.
When two or more head expansion units are connected: 0 to +40 °C 32 to 104 °F.

Relative humidity

35 to 85 % RH (No condensation)

Weight

Approx. 600 g

*1 NPN open-collector output rating: 50 mA max. (40 V max.), Residual voltage: 0.5 V max.
PNP open-collector output rating: 50 mA max. (30 V max.), Residual voltage: 0.5 V max.
Non-voltage input rating: ON voltage: 1 V max., OFF current: 0.6 mA max.
Voltage input rating: Maximum input rating: 26.4 V, ON voltage: 10.2 V, OFF current: 0.6 mA
Part of the input/output circuit of the LK-G5000 Series is internally common. Be careful that no potential difference is generated between the internally common terminals due to the potential difference between the cables/external devices. For details, refer to "Precautions on wiring" in the User's Manual.
*2 NPN open-collector output rating: 50 mA max. (40 V max.), Residual voltage: 0.5 V max.
PNP open-collector output rating: 50 mA max. (30 V max.), Residual voltage: 0.5 V max.
Non-voltage input rating: ON voltage: 1 V max., OFF current: 0.6 mA max.
Voltage input rating: Maximum input rating: 26.4 V, ON voltage: 10.2 V, OFF current: 0.6 mA
Part of the input/output circuit of the LK-G5000 Series is internally common. Be careful that no potential difference is generated between the internally common terminals due to the potential difference between the cables/external devices. For details, refer to "Precautions on wiring" in the User's Manual. This input is applied to all of the synchronized OUT.
*3 When a PC supporting USB 1.1 or USB 2.0 full speed is connected, the data refresh cycle and other operations may slow down.
*4 Use the Ethernet interface only for direct connections with a PC or for local network connections with a PC or LK-G5000 Series units.
*5 The EtherNet/IP™ interface cannot be used when a CC-Link unit or a DeviceNet® unit is installed.
EtherNet/IP™ is supported by the latest controllers. For details on which controllers support EtherNet/IP™ , contact your nearest KEYENCE office.

FS-N18N Keyence
Keyence FS-N18N Keyence
Sale price $130.56
In stock, 43 units

Keyence FS-N18N Digital Fiber Optic Sensor, Fiber Amplifier

NJ501-1400 Omron
Omron NJ501-1400 Omron
Sale price $2,878.08
Only 7 units left

Sysmac NJ5 CPU 20MB memory built-in EtherCAT (32 servo axes in total 192 EtherCAT nodes) and EtherNet/IP

Omron New Stock Image
Omron NX502-1300 Omron
Sale price $3,367.03
Only 9 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

NX-SL3300 Omron
Omron NX-SL3300 Omron
Sale price $501.98
In stock, 16 units

Safety controller 32 safety master connections up to 256 safety I/O

OS32C-BP-4M Omron
Omron OS32C-BP-4M Omron
Sale price $6,571.46
Only 3 units left

Safety laser scanner, safety radius 4 m, warning zone 15 m, PLd & Cat 3, 24 VDC, back location cable exit

Keyence New Stock Image
Keyence LV-N12P Keyence
Sale price $305.76
Only 7 units left

Specifications

Model

LV-N12P

Type

2 output

Output

PNP

Cable/connector

Cable

Main/Expansion unit

Expansion unit

I/O

Control outputs

2 output

External input

1 input

Monitor output

None

Output selection

LIGHT-ON/DARK-ON (switch-selectable)

Timer function

Timer OFF/OFF-delay timer/ON-delay timer/One-shot timer,
Timer duration selectable: 1 ms to 9,999 ms,
Maximum error against the setting value: ±10% max.

Control outputs

PNP open collector 30 V, Residual voltage 1.2 V or less (Output current: 10 mA or less) / 2.2 V or less (Output current: 10 to 100 mA)
(Stand-alone) 1 output max: 100 mA or less, 2 output total: 100 mA or less
(Multiple connections) 1 output max: 20 mA or less

Response time

80 µs (HIGH SPEED)/250 µs (FINE)/500 µs (TURBO)/1 ms (SUPER)/4 ms (ULTRA)/16 ms (MEGA) *1

Monitor output

-

External input

Input time 2 ms (ON)/20 ms (OFF) or more*2

Number of interference
prevention units

Connected to other than LV-S31: 0 for HIGH SPEED; 2 for FINE/TURBO/SUPER; 4 for ULTRA/MEGA,
Connected to LV-S31: 2 for FINE; 4 for TURBO/SUPER/ULTRA/MEGA*3

Case size

H 32.6 mm 1.28" × W 9.8 mm 0.39" × L 78.7 mm 3.1"

Unit expansion

Up to 17 units can be connected in total (two-output type is treated as two units)

Protection circuit

Reverse polarity protection, Over-current protection, Surge absorber

Rating

Power voltage

24 VDC (operating voltage 10 to 30 VDC (with ripple)), Ripple (P-P) 10 % or less, Class 2 or LPS*4*5

Power
consumption

Normal: 950 mW or less (at 30 V. 33 mA at 24 V, 60 mA or less at 12 V)*6
Eco on mode: 815 mW or less (at 30 V. 29 mA at 24 V, 52 mA or less at 12 V)*6
Eco Full mode: 650 mW or less (at 30 V. 24 mA at 24 V, 40 mA or less at 12 V)
*7

Environmental resistance

Ambient temperature

-20 to +55 °C -4 to 131 °F (No freezing)*8

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

500 m/s2, 3 times in each of the X, Y, and Z directions

Material

Cable

PVC

Case

Main unit and cover material: Polycarbonate

Weight

Approx. 65 g

*1 80 µs cannot be selected when the LV-S31/S62/S63 is connected
*2 Input time is 25 ms (ON)/25 ms (OFF) when external calibration time is selected.
*3 These numbers double when "DOUBLE" is selected.
*4 Use with the over current protection device which is rated 30 V or more and not more than 1 A.
*5 To connect more than 9 units, the power voltage must be 20 V or more.
*6 Increases 30 mW (1 mA) for HIGH SPEED mode.
*7 It increases by 15% when connected to the LV-NH100/NH110/NH300. It does not include the power consumption of the load.
Power consumption when expansion units are connected is the total power consumption of each amplifier unit. Example: When one main unit (LV-N11N) is connected to 2 expansion units (LV-N12N) and they are used with LV-NH100 heads in HIGH SPEED mode.
(1.15 × 860 mW × 1) + (1.15 × 860 mW × 2) = 2967 mW max.
*8 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less for a unit.
One or two more units connected: -20 to +55 °C -4 to 131 °F; 3 to 10 more units connected: -20 to +50 °C -4 to 122 °F; 11 to 16 more units connected: -20 to +45 °C -4 to 113 °F. When using 2-outputs, one unit is counted as two units.

CIMR-AC4A0072AAA Omron
Omron CIMR-AC4A0072AAA Omron
Sale price $2,248.52
Only 2 units left

A1000 inverter: 3~ 400 V, HD: 30 kW 60 A, ND: 37 kW 72 A

NX-TS3101 Omron
Omron NX-TS3101 Omron
Sale price $570.57
Only 7 units left

Controllers NX 4Pt Thermocouple

NX-DA3203 Omron
Omron NX-DA3203 Omron
Sale price $399.08
Only 6 units left

Controllers NX 4Pt D/A 4-20m 1/8k 250us/pt

Keyence New Stock Image
Keyence FD-Q10C Keyence
Sale price $544.13
In stock, 11 units

Specifications

Model

FD-Q10C

Supported pipe diameter

1/4" (8 A), ø13 to ø16 (mm)
3/8" (10 A), ø16 to ø18 (mm)

Supported pipe materials

Metal pipe/Resin pipe*1

Supported fluids

Various liquid [i.e. water (including DI), oils, chemicals, etc.]*1

Supported fluid temperature

0 to 85°C 32 to 185°F (No freezing on the pipe surface)*2

Maximum rated flow

1/4" (8 A): 20 L/min, 5.2 G/min
3/8" (10 A): 30 L/min, 7.9 G/min

Zero cut flow rate

1.0 L/min (Default)*3

Display method

Status indicator, output indicator, dual row display with 4-digit, 7 segment LED, stability level indicator

Display update cycle

Approx. 3 Hz

Display resolution

0.01/0.1/1 (Default : 0.1) (L/min)

Response time

0.5 s / 1.0 s / 2.5 s / 5 s / 10 s / 30 s / 60 s

Protection circuit

Power supply reverse connection protection, power supply surge protection,
each output short-circuit protection, each output surge protection

Repeatability

0.5 s : ±2.0%, 1 s:±1.5%, 2.5 s : ±1.0%, 5 s : ±0.5%, 10 s : ±0.35%, 30 s : ±0.2%, 60 s : ±0.15% (/F.S.*4(Specific to selected response time))

Hysteresis

Variable

Integrated flow unit display

0.1/ 1/ 10/ 100/ 1000 (Default : 1) (L)

Integrated flow data storage cycle

Save to memory every 10 seconds

Memory backup

EEPROM (Data storage length: 10 years or longer, Data read/write frequency: 1 million times or more)

Power I/O connector

M12 4-pin connector

Input/Output (Selectable)

Output (ch.1/ch.2)

Control output/ Pulse output/ Error output (Selectable, Default : ch.1 control output/ ch.2 not used),
NPN/PNP setting switchable,open collector output 30 V or less, max. 100 mA/ch., residual voltage 2.5 V or less*5

Analog output (ch.2)

4 to 20 mA / 0 to 20 mA (Selectable, Default: not used), load resistance 500 Ω or less*5

External input (ch.2)

Integrated flow reset input/ Flow rate zero input/ Origin adjustment input (Selectable, Default: not used),
short-circuit current 1.5 mA or less, input time 20 ms or more*5

Power supply

Power voltage

20 to 30 VDC , ripple (P-P) 10% max, Class2/LPS

Current consumption

100 mA or less (Load current excluded)*6

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Ambient temperature

-10 to +60 °C 14 to 140 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

100 m/s2, 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Material

Sensor main unit

PPS/PES/PBT/SUS303/SUS304/SUSXM7

Sensor surface

Rubber

Mounting bracket

SUS304/PA/SUSXM7

Weight

Approx. 340 g (including mounting bracket)

*1 Liquid must allow for the passage of an ultrasonic pulse, as well as not contain large air pockets or excessive bubbles. Detection may be unstable on certain non-standard pipes (i.e. lined pipes)
*2 Contact KEYENCE when the temperature of the pipe is greater than 85°C 185°F
*3 The zero cut flow rate can be changed in the settings. When using the unit with a low flow rate range, perform an origin adjustment when the fluid is not moving if you change the zero cut flow rate.
*4 This specification is valid when the flow velocity distribution is stable. This value does not take into account the effects of pulsation or fluctuations in flow velocity distribution due to facility factors. Convert the F.S. (full scale) listed in the table according to the rated flow range.
*5 IO-Link: Compatible with Specification v1.1 / COM2 (38.4 kbps) The setting file can be downloaded from the KEYENCE website. If using the unit in the environment where downloading the file is not possible via internet, contact your nearest KEYENCE office. IO-Link is either registered trademarks or trademarks of PROFIBUS Nutzerorganisation e.V. (PNO)
*6 When including the loads, please add 200 mA to this value.

FS-V31CP Keyence
Keyence FS-V31CP Keyence
Sale price $246.18
In stock, 64 units

Specifications

Model

FS-V31CP

Type

1-output + 1-input
with M8 connector

Output

PNP

Main unit/Expansion unit

Main unit

Control output

1 output

Monitor output (1 to 5 V)

N/A

External input

1 input

Connector

M8

Light source LED

Red, 4-element LED (Wavelength: 640 nm)

Response time

33 µs (HIGH SPEED) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER TURBO) /4 ms (ULTRA TURBO) /16 ms (MEGA TURBO)

Output selection

LIGHT-ON/DARK-ON (switch-selectable)

Display indicator

Operation indicator: Red LED/Dual digital monitor: Dual 7-segment display, Preset Value (4-digit green LED indicator) and
Current Value (4-digit red LED indicator) illuminated together. Current Value range: 0 to 64,512; Excess gain: 0P to 999P,
Hold function: Possible to display both peak and bottom hold values, Selectable from 5 variations
Bar LED monitor: Excess gain displayed (85% to 115% in 7 steps), Scaling display

Size

30.3 mm (H) x 9.8 mm (W) x 71.8 mm (D) 1.19" (H) x 0.39" (W) x 2.83" (D)

Detection mode

Light intensity (area detection possible, automatic sensitivity-tracking function provided)

Timer function

OFF-delay timer/ON-delay timer/One-shot timer/ON-delay timer + OFF-delay timer/ON-delay timer + One-shot timer, selectable
Timer duration selectable: 0.1 ms to 9,999 ms, Maximum error against the setting value: ±10% max.

Control output

PNP open-collector 24 V, 100 mA max.*1 (main unit only)/20 mA max. (when the expansion unit(s) is connected), Residual voltage: 1 V max.

External inputy

Input time: 2 ms (ON)/20 ms (OFF) min.*2

Unit expansion

Up to 16 expansion units can be connected (a total of 17 units). Note that the 2-output type should be counted as two units.

Number of interference prevention units

Normal operation

HIGHSPEED:0 FINE:4 TURBO/SUPER/ULTRA/MEGA:8台

Rating

Power voltage

12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less

Power consumption

Normal: 750 mW max. (Using 24 V, 31 mA max., using 12 V, 40 mA max.)/
Power saving 580 mW max. (Using 24 V, 24 mA max., using 12 V,
28 mA max.)*3

Environmental resistance

Ambient light

Incandescent lamp: 20,000 lux max., Sunlight: 30,000 lux max.

Ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)*4

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

500 m/s2, 3 times in each of the X, Y, and Z directions

Case material

Polycarbonate

Accessories

N/A

Weight

Approx. 80 g

*1 Total current of two outputs should be less than 100 mA.
*2 Only available on certain models.
*3 When using the HIGH SPEED mode, the power consumption increases by 160 mW (7 mA).
*4 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less.
1 to 2 Units: -10 to +55 °C 14 to 131 °F, 3 to 10 Units: -10 to +50 °C 14 to 122 °F, 11 to 16 Units: -10 to +45 °C 14 to 113 °F

Balluff Stock Image
Balluff BNS005M Balluff
Sale price $300.38
Only 4 units left
Balluff BNS Mechanical Position Switch (P/N: BNS005M). Mechanical cam-operated position switch for precise machine positioning, tool change monitoring, and rotary table indexing. Multiple switching positions with roller plunger actuators, IP67 protection, and configurable contact configurations for machine tools, transfer lines, and packaging machinery.
NX-OD5121 Omron
Omron NX-OD5121 Omron
Sale price $136.10
In stock, 11 units

I/O Modules NX 16Pt 12-24VDC NPN Trans Out

GX-JC06 Omron
Omron GX-JC06 Omron
Sale price $312.23
Only 10 units left

Ethernet Modules EtherCAT 6 Port Branching Unit

NX-EC0222 Omron
Omron NX-EC0222 Omron
Sale price $319.04
Only 7 units left

Controllers NX 2Pt Inc Enc 24V PNP

E3Z-T86 Omron
Omron E3Z-T86 Omron
Sale price $97.23
Only 6 units left

Through-beam type, PNP output, Sensing distance 15 m, M8 connector models

S8VK-G12024 Omron
Omron S8VK-G12024 Omron
Sale price $136.10
Only 7 units left

DIN Rail Power Supplies 120W 24VDC 5A

LK-G5001V Keyence
Keyence LK-G5001V Keyence
Sale price $2,253.37
Only 5 units left

Specifications

Model

LK-G5001V*1*2

Separate type

LK-G5001/LK-HD500

Type

Main controller

Sensor head compatibility

Compatible

No. of connectable sensor heads

2

Display

Minimum display unit

LK-HD500: 0.001 µm

Display range

LK-HD500: ±999.999 µm to ±9,999.99 mm (7 settings selectable)

Display cycle

LK-HD500: Approx. 10 times/sec.

Display interface

Display port

Either the display unit (LK-HD500) or dedicated touch panel (LK-HD1001) can be connected

LED indicator

LASER ON

Terminal block

Analog output voltage

±10 V output, Output impedance: 100 Ω

Analog current output

4 to 20 mA, Maximum load resistance: 350 Ω

No. of analog outputs

2

TIMING 1 input

Non-voltage input*3

RESET 1 input

Auto-zero 1 input

Laser control input

Non-voltage input*4

Laser remote input

Non-voltage input

Alarm output

NPN open-collector output

General comparator output

Expansion connector

TIMING input

Non-voltage input

RESET input

Auto-zero input

Program switching input

Binary selection input

Alarm output

NPN open-collector output

Comparator output

Binary output

RS-232C interface

Baud rate: 9,600 to 115,200 bps
Data length: 8 bits, Stop bit length: 1 bit, Parity: None/even/odd

USB interface

USB 2.0 Hi-Speed compliant*5

Ethernet interface

100Base-TX/10Base-T*6

EtherNet/IP™interface

Cyclic communication (implicit messaging)
Message communication (explicit messaging) : UCMM and Class3 Number of connections: 32 Complies with conformance test version CT14*7

PLC-Link

The following PLCs are supported:Mitsubishi Electric: MELSEC iQ-R Series, iQ-F Series, Q Series, L Series, FX Series
EtherNet/IP™, CC-Link, and DeviceNet® cannot be used in conjunction with PLC-Link

Head expansion unit connector

Up to 10 head expansion units can be connected to one main controller

Expansion unit connector

Either of the CC-Link unit (LK-CC100) or DeviceNet® unit (LK-DN100) can be connected

Power supply

Power supply voltage

24 VDC ±10 %

Maximum current consumption

0.6 A or less with 1 head/3.5 A or less with 12 heads

Environmental resistance

Ambient temperature

When one or less head expansion unit is connected: 0 to +50 °C 32 to 122 °F.
When two or more head expansion units are connected: 0 to +40 °C 32 to 104 °F.

Relative humidity

35 to 85 % RH (No condensation)

Weight

Approx. 600 g

*1 NPN open-collector output rating: 50 mA max. (40 V max.), Residual voltage: 0.5 V max.
Non-voltage input rating: ON voltage: 1 V max., OFF current: 0.6 mA max.
*2 Part of the input/output circuit of the LK-G5000 Series is internally common. Be careful that no potential difference is generated between the internally common terminals due to the potential difference between the cables/external devices. For details, refer to "Precautions on wiring" in the User's Manual.
*3 This input is applied to all of the synchronized OUT.
*4 When the laser class 3B sensor head is connected, a key-operated switch must be used for the input to this terminal. The laser is emitted only when the key-operated switch is set to the ON position. (Select a key which can be removed only when it is set to the OFF position.)
When the laser class 2/3R sensor head is connected, the laser turns on when this terminal is opened and turns off when it is short-circuited.
*5 When a PC supporting USB 1.1 or USB 2.0 full speed is connected, the data refresh cycle and other operations may slow down.
*6 Use the Ethernet interface only for direct connections with a PC or for local network connections with a PC or LK-G5000 Series units.
*7 The EtherNet/IP™ interface cannot be used when a CC-Link unit or a DeviceNet® unit is installed.
EtherNet/IP™ is supported by the latest controllers. For details on which controllers support EtherNet/IP™ , contact your nearest KEYENCE office.

Keyence New Stock Image
Keyence GT2-A50 Keyence
Sale price $1,111.83
In stock, 14 units

Specifications

Model

GT2-A50

Detection system

Quartz glass scale, CMOS image sensor projection system, Absolute type (without tracking error)

Measuring range

50 mm 1.97"

Resolution

0.5 μm 0.02 Mil

Indicated accuracy

3.5 µm 0.14 Mil (p-p)*1

Measuring force

Downward mounting

3.2 N*2

Side mounting

2.8 N*2

Upward mounting

2.4 N*2

Sampling cycle

1 ms

Operation indicator light

2-color LED (red, green)

Environmental resistance

Enclosure rating

IP67*3

Pressure resistance

1 MPa

Applied pressure range

0.25 to 0.5 MPa

Ambient temperature

0 to +55 °C 32 to 131 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions*4

Materials

Main body

Main body case: Zinc die-casting; Cylinder part: Aluminium alloy;
Air joint resin part: Polyacetal; Air joint metal part: Brass nickel plating; Indicator: Polyarylate

Dust boot

NBR

Contact

TYPE304, 440C Stainless steel*5

Sensor head cable

Optional (connect to the M8 connector)

Weight

Approx. 405 g (excluding cable)

*1 Value when the ambient temperature is 20 °C 68 °F.
*2 Value at center of measuring range. Please note that the measurement force changes depending on the installation state of the dust boots.
*3 Make sure the air tube is connected to the air exhaust joint and that no foreign materials enter inside from the joint.
*4 In the case where a mounting bracket D is used with GT2-A32 and GT2-A50, the double amplitude becomes 0.75 mm 0.03".
*5 The contact is included with the sensor.

Sick New Stock Image
Sick RT-P3221 SICK
Sale price $164.22
Only 9 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Pepperl+Fuchs Stock Image
Pepperl+Fuchs KFD2-SOT2-EX2 Pepperl+Fuchs
Sale price $250.65
Only 9 units left
Pepperl+Fuchs KFD2 Signal Conditioner (P/N: KFD2-SOT2-EX2). K-System isolated barrier with galvanic isolation, ATEX/IECEx certification for 4-20mA, HART, thermocouple, RTD, and NAMUR process signals. DIN-rail mounted with spring terminals.

Recently viewed