Filters

Measurement Sensors

719 products

Showing 121 - 144 of 719 products

Showing 121 - 144 of 719 products
View
LK-G30 Keyence
Keyence LK-G30 Keyence
Sale price $1,491.33
In stock, 67 units

Specifications

Model

LK-G30

Reference distance

30 mm 1.18"(Diffuse reflection), 23.5 mm 0.93"(Specular reflection)

Measuring range

±5 mm ±0.2"(Diffuse reflection),±4.5 mm ±0.18"(Specular reflection)

Light source

Type

Red semiconductor laser

Wavelength

655nm (Visible light), Class 3R laser product (JIS C6802)

Laser Class

Class 3R (IEC 60825-1), Class IIIa (FDA CDRH Part 1040.10)

Output

4.8 mW

Spot diameter (at reference distance)

Approx. ø30 µm ø0.001181"

Linearity

±0.05% of F.S. (F.S.= ±5 mm ±0.2")*1

Repeatability

0.05 µm (0.01 µm)*2

Sampling frequency

20/50/100/200/500/1,000 µs (Selectable from 6 levels)

LED display

Near the center of the measurement: Green lights
Within the measurement area: Orange lights
Outside the measurement area: Orange flashing

Temperature characteristics

0.01% of F.S./°C (F.S.= ±5 mm ±0.2")

Environmental resistance

Enclosure rating

IP67 (IEC60529)

Ambient light

Incandescent lamp or Fluorescent lamp: 10,000 lux max.

Ambient temperature

0 to +50 °C 32 to 122 °F

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Aluminum die-cast

Weight

Approx. 280 g (including the cable)

*1 This value was taken when measuring a KEYENCE standard target (ceramic) in standard mode.
*2 These values were taken when measuring a KEYENCE standard target (SUS) at a reference distance and with the number of averaging measurements set to 4,096

LK-G157 Keyence
Keyence LK-G157 Keyence
Sale price $2,583.60
In stock, 63 units

Specifications

Model

LK-G157

Reference distance

Diffused reflection: 150 mm 5.91", Specular reflection: 147.5 mm 5.81" (Specular reflection)

Measuring range

Diffused reflection: ±40 mm ±1.57", Specular reflection: ±39 mm ±1.54"*1*2

Light source

Type

Red semiconductor laser

Wavelength

655 nm (visible light)

Laser Class

Class II (FDA CDRH 21CFR PART1040.10)

Output

0.95 mW

Spot diameter (at reference distance)

Approx. 120 x 1,700 µm
0.0047" x 0.0669"

Linearity

±0.05 % of F.S. (F.S.= ±40 mm ±1.57")*3

Repeatability

0.5 µm 0.000020"*4

Sampling frequency

20 / 50 / 100 / 200 / 500 / 1,000 µs (Selectable from 6 levels)

LED display

Near the center of the measurement: Green lights
Within the measurement area: Orange lights
Outside the measurement area: Orange flashing

Temperature characteristics

0.01 % of F.S./°C (F.S.= ±40 mm ±1.57")

Environmental resistance

Enclosure rating

IP67 (IEC60529)

Ambient light

Incandescent lamp or Fluorescent lamp: 5,000 lux max.

Ambient temperature

0 to +50 °C 32 to 122 °F

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Aluminum die-cast

Weight

Approx. 290 g (including the cable)

*1 The range is obtained by measuring KEYENCE's standard target (ceramic).
*2 When the sampling rate is 20 µs, the range becomes -9 -0.35" (NEAR side) to -15 mm -0.59" (NEAR side) for Diffused reflection, and -8.7 -0.34" (NEAR side) to -14 mm -0.55" (NEAR side) for specular reflection.
*3 The range is obtained by measuring KEYENCE's standard target (ceramic) with the Standard mode.
*4 The range is obtained by measuring KEYENCE's standard (SUS) with 4,096 times of averaging at the reference distance.

LK-G155 Keyence
Keyence LK-G155 Keyence
Sale price $2,583.60
In stock, 47 units

Specifications

Model

LK-G155

Reference distance

150 mm 5.91" (Diffuse reflection),147.5 mm 5.81" (Specular reflection)

Measuring range

±40 mm ±1.57" (Diffuse reflection), ±39 mm ±1.54" (Specular reflection)

Light source

Type

Red semiconductor laser

Wavelength

655nm (Visible light), Class 3R laser product (JIS C6802)

Laser Class

Class 3R (IEC 60825-1), Class IIIa (FDA CDRH Part 1040.10)

Output

4.8 mW maximum

Spot diameter (at reference distance)

Approx. 120 x 1700 µm
0.0047 x 0.0669"

Linearity

±0.05% of F.S. (F.S.= ±40 mm ±1.57")*1

Repeatability

0.5 µm 0.000020"*2

Sampling frequency

20/50/100/200/500/1,000 µs (Selectable from 6 levels)

LED display

Near the center of the measurement: Green lights
Within the measurement area: Orange lights
Outside the measurement area: Orange flashing

Temperature characteristics

0.01% of F.S./°C (F.S.= ±40 mm ±1.57")

Environmental resistance

Enclosure rating

IP67 (IEC60529)

Ambient light

Incandescent lamp or Fluorescent lamp: 10,000 lux max.

Ambient temperature

0 to +50 °C 32 to 122 °F

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Aluminum die-cast

Weight

Approx. 290 g (including the cable)

*1 This value was taken when measuring a KEYENCE standard target (ceramic) in standard mode.
*2 These values were taken when measuring a KEYENCE standard target (SUS) at a reference distance and with the number of averaging measurements set to 4,096

LK-G152 Keyence
Keyence LK-G152 Keyence
Sale price $2,507.38
In stock, 68 units

Specifications

Model

LK-G152

Reference distance

Diffused reflection: 150 mm 5.91", Specular reflection: 147.5 mm 5.81" (Specular reflection)

Measuring range

Diffused reflection: ±40 mm ±1.57", Specular reflection: ±39 mm ±1.54"*1*2

Light source

Type

Red semiconductor laser

Wavelength

655 nm (visible light)

Laser Class

Class II (FDA CDRH 21CFR PART1040.10)

Output

0.95 mW

Spot diameter (at reference distance)

Approx. ø120 µm ø0.0047"

Linearity

±0.05 % of F.S. (F.S.= ±40 mm ±1.57")*3

Repeatability

0.5 µm 0.000020"*4

Sampling frequency

20 / 50 / 100 / 200 / 500 / 1,000 µs (Selectable from 6 levels)

LED display

Near the center of the measurement: Green lights
Within the measurement area: Orange lights
Outside the measurement area: Orange flashing

Temperature characteristics

0.01 % of F.S./°C (F.S.= ±40 mm ±1.57")

Environmental resistance

Enclosure rating

IP67 (IEC60529)

Ambient light

Incandescent lamp or Fluorescent lamp: 5,000 lux max.

Ambient temperature

0 to +50 °C 32 to 122 °F

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Aluminum die-cast

Weight

Approx. 290 g (including the cable)

*1 The range is obtained by measuring KEYENCE's standard target (ceramic).
*2 When the sampling rate is 20 µs, the range becomes -9 -0.35" (NEAR side) to -15 mm -0.59" (NEAR side) for Diffused reflection, and -8.7 -0.34" (NEAR side) to -14 mm -0.55" (NEAR side) for specular reflection.
*3 The range is obtained by measuring KEYENCE's standard target (ceramic) with the Standard mode.
*4 The range is obtained by measuring KEYENCE's standard (SUS) with 4,096 times of averaging at the reference distance.

LK-G150 Keyence
Keyence LK-G150 Keyence
Sale price $2,507.38
In stock, 68 units

Specifications

Model

LK-G150

Reference distance

150 mm 5.91" (Diffuse reflection),147.5 mm 5.81" (Specular reflection)

Measuring range

±40 mm ±1.57" (Diffuse reflection), ±39 mm ±1.54" (Specular reflection)

Light source

Type

Red semiconductor laser

Wavelength

655nm (Visible light), Class 3R laser product (JIS C6802)

Laser Class

Class 3R (IEC 60825-1), Class IIIa (FDA CDRH Part 1040.10)

Output

4.8 mW maximum

Spot diameter (at reference distance)

Approx. ø120 µm ø0.004724"

Linearity

±0.05% of F.S. (F.S.= ±40 mm ±1.57")*1

Repeatability

0.5 µm 0.000020"*2

Sampling frequency

20/50/100/200/500/1,000 µs (Selectable from 6 levels)

LED display

Near the center of the measurement: Green lights
Within the measurement area: Orange lights
Outside the measurement area: Orange flashing

Temperature characteristics

0.01% of F.S./°C (F.S.= ±40 mm ±1.57")

Environmental resistance

Enclosure rating

IP67 (IEC60529)

Ambient light

Incandescent lamp or Fluorescent lamp: 10,000 lux max.

Ambient temperature

0 to +50 °C 32 to 122 °F

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Aluminum die-cast

Weight

Approx. 290 g (including the cable)

*1 This value was taken when measuring a KEYENCE standard target (ceramic) in standard mode.
*2 These values were taken when measuring a KEYENCE standard target (SUS) at a reference distance and with the number of averaging measurements set to 4,096

LK-G15 Keyence
Keyence LK-G15 Keyence
Sale price $1,017.21
In stock, 45 units

Specifications

Model

LK-G15

Reference distance

10 mm 0.39"

Measuring range

±1 mm ±0.04"*1*2

Light source

Type

Red semiconductor laser

Wavelength

655 nm (visible light)

Laser Class

Class II (FDA CDRH 21CFR PART1040.10)

Output

0.3 mW

Spot diameter (at reference distance)

Approx. 20 x 500 µm
0.0008" x 0.0197"

Linearity

±0.03 % of F.S. (F.S.= ±1 mm ±0.04")*3

Repeatability

0.02 µm (0.01 µm)*4

Sampling frequency

20 / 50 / 100 / 200 / 500 / 1,000 µs (Selectable from 6 levels)

LED display

Near the center of the measurement: Green lights
Within the measurement area: Orange lights
Outside the measurement area: Orange flashing

Temperature characteristics

0.01 % of F.S./°C (F.S.= ±1 mm ±0.04")

Environmental resistance

Enclosure rating

IP67 (IEC60529)

Ambient light

Incandescent lamp or Fluorescent lamp: 10,000 lux max.

Ambient temperature

0 to +50 °C 32 to 122 °F

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Aluminum die-cast

Weight

Approx. 190 g (including the cable)

*1 The range is obtained by measuring KEYENCE's standard target (ceramic).
*2 When the sampling rate is 20 µs, the range becomes +0.37 mm +0.01" (FAR side) to -1 mm -0.04" (NEAR side).
*3 The range is obtained by measuring KEYENCE's standard target (ceramic) with the Standard mode.
*4 The range is obtained by measuring KEYENCE's standard (SUS) with 4,096 times of averaging at the reference distance. The range in parenthesis is the typical linearity obtained by measuring the target with 16, 384.

LK-G10 Keyence
Keyence LK-G10 Keyence
Sale price $1,017.21
In stock, 45 units

Specifications

Model

LK-G10

Reference distance

10 mm 0.39"

Measuring range

±1 mm ±0.04"*1*2

Light source

Type

Red semiconductor laser

Wavelength

655 nm (visible light)

Laser Class

Class II (FDA CDRH 21CFR PART1040.10)

Output

0.3 mW

Spot diameter (at reference distance)

Approx. ø20 µm ø0.0008"

Linearity

±0.03 % of F.S. (F.S.= ±1 mm ±0.04")*3

Repeatability

0.02 µm (0.01 µm)*4

Sampling frequency

20 / 50 / 100 / 200 / 500 / 1,000 µs (Selectable from 6 levels)

LED display

Near the center of the measurement: Green lights
Within the measurement area: Orange lights
Outside the measurement area: Orange flashing

Temperature characteristics

0.01 % of F.S./°C (F.S.= ±1 mm ±0.04")

Environmental resistance

Enclosure rating

IP67 (IEC60529)

Ambient light

Incandescent lamp or Fluorescent lamp: 10,000 lux max.

Ambient temperature

0 to +50 °C 32 to 122 °F

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Aluminum die-cast

Weight

Approx. 190 g (including the cable)

*1 The range is obtained by measuring KEYENCE's standard target (ceramic).
*2 When the sampling rate is 20 µs, the range becomes +0.37 mm +0.01" (FAR side) to -1 mm -0.04" (NEAR side).
*3 The range is obtained by measuring KEYENCE's standard target (ceramic) with the Standard mode.
*4 The range is obtained by measuring KEYENCE's standard (SUS) with 4,096 times of averaging at the reference distance. The range in parenthesis is the typical linearity obtained by measuring the target with 16, 384.

keyence Stock Image
Keyence LK-G08 Keyence
Sale price $2,393.20
Only 3 units left

Specifications

Model

LK-G08

Reference distance

8 mm 0.32"

Measuring range

±0.8 mm

Light source

Type

Red semiconductor laser

Wavelength

655nm (Visible light), Class 1 laser product (JIS C6802)

Output

0.3 mW

Spot diameter (at reference distance)

Approx. ø20 µm ø0.000787"

Linearity

±0.05% of F.S. (F.S. = ±0.8 mm ±0.03")*1

Repeatability

0.02 µm (0.01 µm)*2

Sampling frequency

20/50/100/200/500/1,000 µs (Selectable from 6 levels)

LED display

Near the center of the measurement: Green lights
Within the measurement area: Orange lights
Outside the measurement area: Orange flashing

Temperature characteristics

0.02% of F.S./°C (F.S. = ±0.8 mm 0.031")

Environmental resistance

Enclosure rating

-

Ambient light

Incandescent lamp or Fluorescent lamp: 10,000 lux max.

Ambient temperature

+10 to +40 °C 50 to 104 °F

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 0.75 mm 0.03", 2 hours in each of the X, Y, and Z directions

Material

Aluminum

Weight

Approx. 245 g (including the cable)

*1 This value was taken when measuring a KEYENCE standard target (ceramic) in standard mode.
*2 These values were taken when measuring a KEYENCE standard target (SUS) at a reference distance and with the number of averaging measurements set to 4,096

LK-G3001V Keyence
Keyence LK-G3001V Keyence
Sale price $1,237.31
In stock, 49 units

Specifications

Model

LK-G3001V*1

Separate type

LK-G3001/LK-GD500*2

Type

All-in-one model

Display

Head compatibility

All LK-G sensor heads are compatible

Number of connectable sensors

Maximum of 2 units

Minimum display unit

0.01 µm

Display range

±9,999.99 mm to ±9,999.99 µm (Selectable from six levels)

Refresh rate

10 times/sec

Terminal block

Analog voltage output

±10 V x 2 outputs, output impedance: 100 Ω

Analog current output

4 to 20 mA x 2 outputs, maximum load resistance: 350 Ω

Timing input

For OUT1, non-voltage input

Reset input

Auto-zero input

Laser remote interlock input

Non-voltage input

Comparator output

For OUT1, NPN open-collector output

Alarm output

For OUT1, NPN open-collector output (N.C.)

Expansion connector

Timing input

For OUT2, non-voltage input

Reset input

Auto-zero input

Program switching input

Non-voltage input x 3 inputs

Laser-Off input

For Head A/Head B, non-voltage input

Comparator output

For OUT2, NPN open-collector output

Alarm output

For OUT2, NPN open-collector output (N.C.)

Binary

Binary output

Measured data output (21 bits), OUT1/OUT2 selectable, NPN open-collector output

Strobe output

NPN open-collector output

Binary selector output

Binary selector input

Non-voltage input

RS-232C interface

Measured data output and control input/output (Maximum baud rate: 115,200 bps, selectable)

USB interface

In conformity with USB Revision 2.0 Full speed (USB1.1 compatible)

Major functions

2 OUT simultaneous measurement, Operation, Averaging, Filter, Calibration, Measurement, AUTO ZERO,
Sampling frequency setting, Mutual interference prevention, Data storage, 8-program memory, ECO mode,
ABLE setting, Target setting, ABLE tuning, Selection of measurement surface of transparent target,
Statistics processing, Connection of setting support software, Selectable head-mounting, etc.

Rating

Power voltage

24 VDC ±10 %, Ripple (P-P) 10 % or less

Current consumption

500 mA or less with 1 head/600 mA or less with 2 heads

Environmental resistance

Ambient temperature

0 to +50 °C 32 to 122 °F

Relative humidity

35 to 85 % RH (No condensation)

Weight

Approx. 480 g

*1 The rating of the NPN open-collector: 50 mA max. (40 V max.), residual voltage of 1 V max.
The rating of non-voltage input: 1 V or less ON voltage, 0.6 mA or less OFF current.
*2 LK-G3001(P) can be operated singly. The measured value display and setting modifications can be performed on the display panel (LK-GD500) or via the setting support software (LK-H1W).

LK-G3001PV Keyence
Keyence LK-G3001PV Keyence
Sale price $1,364.32
In stock, 32 units

Specifications

Model

LK-G3001PV*1

Separate type

LK-G3001P/LK-GD500*2

Type

All-in-one model

Display

Head compatibility

All LK-G sensor heads are compatible

Number of connectable sensors

Maximum of 2 units

Minimum display unit

0.01 µm

Display range

±9,999.99 mm to ±9,999.99 µm (Selectable from six levels)

Refresh rate

10 times/sec

Terminal block

Analog voltage output

±10 V x 2 outputs, output impedance: 100 Ω

Analog current output

4 to 20 mA x 2 outputs, maximum load resistance: 350 Ω

Timing input

For OUT1, voltage input

Reset input

Auto-zero input

Laser remote interlock input

Non-voltage input

Comparator output

For OUT1, PNP open-collector output

Alarm output

For OUT1, PNP open-collector output (N.C.)

Expansion connector

Timing input

For OUT2, voltage input

Reset input

Auto-zero input

Program switching input

Voltage input x 3 inputs

Laser-Off input

For Head A/Head B, voltage input

Comparator output

For OUT2, PNP open-collector output

Alarm output

For OUT2, PNP open-collector output (N.C.)

Binary

Binary output

Measured data output (21 bits), OUT1/OUT2 selectable, PNP open-collector output

Strobe output

PNP open-collector output

Binary selector output

Binary selector input

Voltage input

RS-232C interface

Measured data output and control input/output (Maximum baud rate: 115,200 bps, selectable)

USB interface

In conformity with USB Revision 2.0 Full speed (USB1.1 compatible)

Major functions

2 OUT simultaneous measurement, Operation, Averaging, Filter, Calibration, Measurement, AUTO ZERO,
Sampling frequency setting, Mutual interference prevention, Data storage, 8-program memory, ECO mode,
ABLE setting, Target setting, ABLE tuning, Selection of measurement surface of transparent target,
Statistics processing, Connection of setting support software, Selectable head-mounting, etc.

Rating

Power voltage

24 VDC ±10 %, Ripple (P-P) 10 % or less

Current consumption

500 mA or less with 1 head/600 mA or less with 2 heads

Environmental resistance

Ambient temperature

0 to +50 °C 32 to 122 °F

Relative humidity

35 to 85 % RH (No condensation)

Weight

Approx. 480 g

*1 The rating of the PNP open collector: 50 mA max. (30 V max.), residual voltage of 1 V max.
The rating of voltage input: 10.2 V or more ON voltage (26.4 V max.) 0.6 mA or less OFF current.
*2 LK-G3001(P) can be operated singly. The measured value display and setting modifications can be performed on the display panel (LK-GD500) or via the setting support software (LK-H1W).

LK-G3001P Keyence
Keyence LK-G3001P Keyence
Sale price $1,364.32
In stock, 55 units

Specifications

Model

LK-G3001P*1

Type

Separate monitor model*2

Display

Head compatibility

All LK-G sensor heads are compatible

Number of connectable sensors

Maximum of 2 units

Minimum display unit

0.01 µm

Display range

±9,999.99 mm to ±9,999.99 µm (Selectable from six levels)

Refresh rate

10 times/sec

Terminal block

Analog voltage output

±10 V x 2 outputs, output impedance: 100 Ω

Analog current output

4 to 20 mA x 2 outputs, maximum load resistance: 350 Ω

Timing input

For OUT1, voltage input

Reset input

Auto-zero input

Laser remote interlock input

Non-voltage input

Comparator output

For OUT1, PNP open-collector output

Alarm output

For OUT1, PNP open-collector output (N.C.)

Expansion connector

Timing input

For OUT2, voltage input

Reset input

Auto-zero input

Program switching input

Voltage input x 3 inputs

Laser-Off input

For Head A/Head B, voltage input

Comparator output

For OUT2, PNP open-collector output

Alarm output

For OUT2, PNP open-collector output (N.C.)

Binary

Binary output

Measured data output (21 bits), OUT1/OUT2 selectable, PNP open-collector output

Strobe output

PNP open-collector output

Binary selector output

Binary selector input

Voltage input

RS-232C interface

Measured data output and control input/output (Maximum baud rate: 115,200 bps, selectable)

USB interface

In conformity with USB Revision 2.0 Full speed (USB1.1 compatible)

Major functions

2 OUT simultaneous measurement, Operation, Averaging, Filter, Calibration, Measurement, AUTO ZERO,
Sampling frequency setting, Mutual interference prevention, Data storage, 8-program memory, ECO mode,
ABLE setting, Target setting, ABLE tuning, Selection of measurement surface of transparent target,
Statistics processing, Connection of setting support software, Selectable head-mounting, etc.

Rating

Power voltage

24 VDC ±10 %, Ripple (P-P) 10 % or less

Current consumption

500 mA or less with 1 head/600 mA or less with 2 heads

Environmental resistance

Ambient temperature

0 to +50 °C 32 to 122 °F

Relative humidity

35 to 85 % RH (No condensation)

Weight

Approx. 370 g

*1 The rating of the PNP open collector: 50 mA max. (30 V max.), residual voltage of 1 V max.
The rating of voltage input: 10.2 V or more ON voltage (26.4 V max.) 0.6 mA or less OFF current.
*2 LK-G3001P can be operated singly. The measured value display and setting modifications can be performed on the display panel (LK-GD500) or via the setting support software (LK-H1W).

keyence Stock Image
Keyence OP-86983 Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-86982 Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-84428 Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-84426 Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence LK-F3 Keyence
Sale price$0.00
Sold Out

Specifications

Model

LK-F3

Type

ND Filter

Applicable product

LK-H085/H085

Number included

1

Note

We used when measured with a specular reflection mirror installed.
Measurement object is to allow accurate measurement of the glass surface when strong specular gloss and, more to the optimum laser light intensity attenuation.

keyence Stock Image
Keyence LK-F2 Keyence
Sale price$0.00
Sold Out

Specifications

Model

LK-F2

Type

ND Filter

Applicable product

LK-G3000 series

Number included

1

Note

Used when the mirror surface is measured at a mirror reflection setup.

keyence Stock Image
Keyence CB-A5E Keyence
Sale price $356.93
Only 1 unit left

Specifications

Model

CB-A5E

Length

5 m 16.40'

Weight

Approx. 400 g

Keyence New Stock Image
Keyence CB-A5 Keyence
Sale price $252.57
Only 9 units left

Specifications

Model

CB-A5

Length

5 m 16.40'

Weight

Approx. 400 g

Keyence Stock Image
Keyence CB-A30 Keyence
Sale price $508.73
Only 2 units left

Specifications

Model

CB-A30

Length

30 m 98.42'

Weight

Approx. 2,000 g

Keyence Stock Image
Keyence CB-A20 Keyence
Sale price $1,015.89
Only 5 units left

Specifications

Model

CB-A20

Length

20 m 65.62'

Weight

Approx. 1,400 g

Keyence Stock Image
Keyence CB-A2 Keyence
Sale price $1,059.09
Only 2 units left

Specifications

Model

CB-A2

Length

2 m 6.56'

Weight

Approx. 200 g

Keyence Stock Image
Keyence CB-A10 Keyence
Sale price $742.20
Only 7 units left

Specifications

Model

CB-A10

Length

10 m 32.81'

Weight

Approx. 550 g

keyence Stock Image
Keyence CB-A07 Keyence
Sale price$0.00
Sold Out

Specifications

Model

CB-A07

Length

0.7 m 2.30'

Weight

Approx. 100 g

Recently viewed