keyence Stock Image
Keyence WI-C10L Keyence
Sale price$0.00
Sold Out

Specifications

Model

WI-C10L

Type

Sensor head connecting cable, Standard

Cable end

L-shaped

Length

10 m 32.81'

keyence Stock Image
Keyence WI-C10 Keyence
Sale price$0.00
Sold Out

Specifications

Model

WI-C10

Type

Sensor head connecting cable, Standard

Cable end

Straight

Length

10 m 32.81'

keyence Stock Image
Keyence WI-010 Keyence
Sale price $36,967.75
Only 4 units left

Specifications

Model

WI-010*1*2*3

Reference distance

18 mm 0.71"

Measurement range

Z

1.4 mm 0.06" (Standard Mode), 0.7 mm 0.03" (High Speed Mode)

XY

10 × 10 mm 0.39" × 0.39"

Minimum detection area

40 × 40 µm 0.001575" × 0.001575"

Repeatability (height difference)

0.1 µm 0.000004"*4

Linearity (height difference)

±2.8 µm 0.000110"(±0.2% of F.S., F.S. = 1.4 mm 0.06", +20 to +30°C +68 to +86°F)*5

Light source for measurement

Type

Infrared SLD

Center wavelength

830 nm

Laser class (IEC60825-1)

Class 3R

Output

3.6 mW

Guide light source

Type

Red semiconductor laser

Wavelength

660 nm

Laser class (IEC60825-1)

Class 1

Output

0.15 mW

Sampling frequency

Internal Trigger

133 ms (High Speed Mode), 266 ms (Standard Mode)

External Trigger

266 ms max. (High Speed Mode), 532 ms max. (Standard Mode)*6

Environmental resistance

Ambient light

Incandescent lamp/fluorescent lamp: 5,000 lux max.

Ambient temperature

0 to +35 °C 32 to 95 °F

Relative humidity

20 to 85 % RH (No condensation)

Weight

Approx. 3,000 g

*1 The laser classification for FDA(CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice.The resolution of the height (distance from head reference plane to measurement workpiece) is 1 µm(*2).
*2 This is ±3 σ value (Auto Maintenance Mode is OFF) when the average height of a single rectangular area(*3) has been measured for 30 seconds using a KEYENCE standard target.
*3 The rectangular size is WI-001 : 0.3 mm × 0.9 mm 0.01" × 0.04", WI-004 : 1.1 mm × 3.7 mm 0.04" × 0.15", WI-010 : 3 mm × 9 mm 0.12" × 0.35".
*4 This is σ value (Auto Maintenance Mode is OFF, Capture Timing is “Prioritize Accuracy”) when the average height difference of two rectangular areas(*3) has been measured for 30 seconds using a KEYENCE standard target.
*5 This is the value (Auto Maintenance Mode is OFF, Capture Timing is “Prioritize Accuracy”) when the average height difference of two rectangular areas(*3) has been measured using a KEYENCE standard target.
*6 The workpiece stopping time at capturing is 120 ms (High Speed Mode) or 240 ms (Standard Mode).

keyence Stock Image
Keyence WI-004 Keyence
Sale price$0.00
Sold Out

Specifications

Model

WI-004*1*2*3

Reference distance

18 mm 0.71"

Measurement range

Z

1.4 mm 0.06" (Standard Mode), 0.7 mm 0.03" (High Speed Mode)

XY

4 × 4 mm 0.16" × 0.16"

Minimum detection area

15 × 15 µm 0.000591" × 0.000591"

Repeatability (height difference)

0.1 µm 0.000004"*4

Linearity (height difference)

±2.8 µm 0.000110"(±0.2% of F.S., F.S. = 1.4 mm 0.06", +20 to +30°C +68 to +86°F)*5

Light source for measurement

Type

Infrared SLD

Center wavelength

830 nm

Laser class (IEC60825-1)

Class 3R

Output

3.6 mW

Guide light source

Type

Red semiconductor laser

Wavelength

660 nm

Laser class (IEC60825-1)

Class 1

Output

0.15 mW

Sampling frequency

Internal Trigger

133 ms (High Speed Mode), 266 ms (Standard Mode)

External Trigger

266 ms max. (High Speed Mode), 532 ms max. (Standard Mode)*6

Environmental resistance

Ambient light

Incandescent lamp/fluorescent lamp: 5,000 lux max.

Ambient temperature

0 to +35 °C 32 to 95 °F

Relative humidity

20 to 85 % RH (No condensation)

Weight

Approx. 3,000 g

*1 The laser classification for FDA(CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice.The resolution of the height (distance from head reference plane to measurement workpiece) is 1 µm(*2).
*2 This is ±3 σ value (Auto Maintenance Mode is OFF) when the average height of a single rectangular area(*3) has been measured for 30 seconds using a KEYENCE standard target.
*3 The rectangular size is WI-001 : 0.3 mm × 0.9 mm 0.01" × 0.04", WI-004 : 1.1 mm × 3.7 mm 0.04" × 0.15", WI-010 : 3 mm × 9 mm 0.12" × 0.35".
*4 This is σ value (Auto Maintenance Mode is OFF, Capture Timing is “Prioritize Accuracy”) when the average height difference of two rectangular areas(*3) has been measured for 30 seconds using a KEYENCE standard target.
*5 This is the value (Auto Maintenance Mode is OFF, Capture Timing is “Prioritize Accuracy”) when the average height difference of two rectangular areas(*3) has been measured using a KEYENCE standard target.
*6 The workpiece stopping time at capturing is 120 ms (High Speed Mode) or 240 ms (Standard Mode).

keyence Stock Image
Keyence WI-001 Keyence
Sale price$0.00
Sold Out

Specifications

Model

WI-001*1*2*3

Reference distance

18 mm 0.71"

Measurement range

Z

1.4 mm 0.06" (Standard Mode), 0.7 mm 0.03" (High Speed Mode)

XY

1 × 1 mm 0.04" × 0.04"

Minimum detection area

4 × 4 µm 0.000157" × 0.000157"

Repeatability (height difference)

0.1 µm 0.000004"*4

Linearity (height difference)

±2.8 µm 0.000110"(±0.2% of F.S., F.S. = 1.4 mm 0.06", +20 to +30°C +68 to +86°F)*5

Light source for measurement

Type

Infrared SLD

Center wavelength

830 nm

Laser class (IEC60825-1)

Class 3R

Output

3.6 mW

Guide light source

Type

Red semiconductor laser

Wavelength

660 nm

Laser class (IEC60825-1)

Class 1

Output

0.15 mW

Sampling frequency

Internal Trigger

133 ms (High Speed Mode), 266 ms (Standard Mode)

External Trigger

266 ms max. (High Speed Mode), 532 ms max. (Standard Mode)*6

Environmental resistance

Ambient light

Incandescent lamp/fluorescent lamp: 5,000 lux max.

Ambient temperature

0 to +35 °C 32 to 95 °F

Relative humidity

20 to 85 % RH (No condensation)

Weight

Approx. 3,000 g

*1 The laser classification for FDA(CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice.The resolution of the height (distance from head reference plane to measurement workpiece) is 1 µm(*2).
*2 This is ±3 σ value (Auto Maintenance Mode is OFF) when the average height of a single rectangular area(*3) has been measured for 30 seconds using a KEYENCE standard target.
*3 The rectangular size is WI-001 : 0.3 mm × 0.9 mm 0.01" × 0.04", WI-004 : 1.1 mm × 3.7 mm 0.04" × 0.15", WI-010 : 3 mm × 9 mm 0.12" × 0.35".
*4 This is σ value (Auto Maintenance Mode is OFF, Capture Timing is “Prioritize Accuracy”) when the average height difference of two rectangular areas(*3) has been measured for 30 seconds using a KEYENCE standard target.
*5 This is the value (Auto Maintenance Mode is OFF, Capture Timing is “Prioritize Accuracy”) when the average height difference of two rectangular areas(*3) has been measured using a KEYENCE standard target.
*6 The workpiece stopping time at capturing is 120 ms (High Speed Mode) or 240 ms (Standard Mode).

keyence Stock Image
Keyence CA-E300LJ Keyence
Sale price$0.00
Sold Out

Specifications

Model

CA-E300LJ

Controller

XG-X2902LJ

Head input

2 points *1

Supported heads

LJ-S015/LJ-S025/LJ-S040/LJ-S080/LJ-S160/LJ-S320/LJ-S640

Power supply

Supplied from controller

Environmental resistance

Ambient temperature

0 to +45°C 32 to 113°F (DIN rail mount) / 0 to +40°C 32 to 104°F (base surface mount)

Relative humidity

85% RH or less (no condensation)

Weight

Approx. 560 g 19.77 oz

*1 When two input units are connected, one head can be connected to each unit. In such configurations, the heads can be different models.

keyence Stock Image
Keyence OP-88837 Keyence
Sale price $1,418.61
Only 1 unit left

Specifications

Model

OP-88837

Length

10 m 32.8'

Keyence Stock Image
Keyence WI-5000 Keyence
Sale price $36,967.75
Only 4 units left

Specifications

Model

WI-5000

No. of connectable sensor heads

1

No. of registration settings

Up to 1000 settings on SD Card 1 and SD Card 2 individually (depending on the capacity and configuration of the SD Card),external switching possible

No. of measurement tools

100 tools/setting (20 are intended for position adjustment)

Measurement mode

Height

Height Measurement, Height Difference Measurement, Arranged Multi-Point Height Measurement, Free Multi-Point Height Measurement, Profile Measurement, and Continuous Height Measurement

Dimension measurement

Measure Distance, Measure Width, Line/Angle, Detect Circle, and Detect Point

Auxiliary function

Calculation, Image Region Generator, Line Display, Circle Display, Point Display, and Scale Display

Interface

Control input

20 (Input terminal: 5, Parallel I/O: 15)

Control output

28 (Output terminal block: 6, Parallel I/O: 22)
Photo MOSFET*1

RS-232C

Value output and control I/O (cannot be used when PLC link using the RS-232C port is in use)

PLC-Link

Value output and control I/O using the Ethernet port or RS-232C port (cannot be used when EtherNet/IP™ is in use.
RS-232C No-protocol communication cannot be used when the RS-232C port is in use)

Ethernet

Value output and control I/O
In addition to the functions above, uploading/downloading inspection settings, various simulations, and transmission/reception/remote connection of image and other data are possible when KEYENCE's PC application software is connected.
FTP client/server function supported, VNC server function (supporting monitor screen display only on clients other than a PC), and BOOTP function supported
1000BASE-T/100BASE-TX/10BASE-T

USB

In addition to value output and control I/O, uploading/downloading inspection settings, various simulations, and transmission/reception/remote connection of image and other data are possible when KEYENCE's PC application software is connected.
Dedicated USB 2.0

EtherNet/IP™

Value I/O and control I/O using the Ethernet port (cannot be used when PLC-Link is in use)
Cyclic communication supported (up to 1436 bytes), message communication supported
Max. number of connections: 32
Conforms to Conformance test Version CT12.

Mouse

Menus can be operated with the optional dedicated mouse (OP-87506, included with the controller).

USB HDD

Image and other data can be output when a HDD (2 TB max.) is connected to the dedicated USB port (conforms to USB3.0, bus power supported: rated output 900 mA)

Monitor output

Analog RGB output XGA 1024 × 768 (24-bit color, 60 Hz)

Minimum display unit

0.1 µm, 0.001°, 0.0001 mm2, 0.00001 mm3

Display language

English/Japanese/Chinese (simplified)/Chinese (traditional)/Korean selectable (Initial language should be determined during the initial startup.)

Rating

Maximum current consumption

2.7 A

Power voltage

24 VDC ±10 %

Environmental resistance

Ambient temperature

0 to +45 °C 32 to 113 °F (DIN rail mounting), 0 to +40 °C 32 to 104 °F (bottom mounting)

Relative humidity

35 to 85 % RH (No condensation)

Weight

Approx. 2,000 g

*1 Either positive common connecting which is compatible with NPN input devices, or negative common connecting which is compatible with PNP input devices is feasible.

keyence Stock Image
Keyence OP-88836 Keyence
Sale price $358.50
Only 2 units left

Specifications

Model

OP-88836

Length

5 m 16.4'

keyence Stock Image
Keyence OP-88835 Keyence
Sale price $37,597.50
Only 3 units left

Specifications

Model

OP-88835

Length

2 m 6.6'

keyence Stock Image
Keyence GR-M256 Keyence
Sale price$0.00
Sold Out

Specifications

Model

GR-M256

Type

CF Memory

Applicable product

GR-7000 Series, GR-3500 Series, NR-600 Series

Memory capacity

256 MB

keyence Stock Image
Keyence OP-88826 Keyence
Sale price$0.00
Sold Out

Specifications

Model

OP-88826

Length

L-shaped/0.2 m 0.7'

keyence Stock Image
Keyence OP-88825 Keyence
Sale price$0.00
Sold Out

Specifications

Model

OP-88825

Length

L-shaped/0.2 m 0.7'

keyence Stock Image
Keyence LJ-GC5 Keyence
Sale price $662.67
Only 3 units left

Specifications

Model

LJ-GC5

Type

Cable between the head and controller

Applicable product

LK-G3000 series

Number included

1

Cable end

Straight

Length

5 m 16.40'

Weight

Approx. 400 g

keyence Stock Image
Keyence LJ-GC30 Keyence
Sale price$0.00
Sold Out

Specifications

Model

LJ-GC30

Type

Cable between the head and controller

Applicable product

LK-G3000 series

Number included

1

Cable end

Straight

Length

30 m 98.42'

Weight

Approx. 2,000 g

keyence Stock Image
Keyence LJ-GC20 Keyence
Sale price $426.83
Only 1 unit left

Specifications

Model

LJ-GC20

Type

Cable between the head and controller

Applicable product

LK-G3000 series

Number included

1

Cable end

Straight

Length

20 m 65.62'

Weight

Approx. 1,400 g

Keyence New Stock Image
Keyence LJ-GC2 Keyence
Sale price $798.20
Only 5 units left

Specifications

Model

LJ-GC2

Type

Cable between the head and controller

Applicable product

LK-G3000 series

Number included

1

Cable end

Straight

Length

2 m 6.56'

Weight

Approx. 200 g

Keyence Stock Image
Keyence CA-U5 Keyence
Sale price $644.99
Only 6 units left

Specifications

Model

CA-U5

Input conditions

Rated input voltage

85 to 264 VAC 47 to 63 Hz, 110 to 370 VDC *1

Inputconditions

Efficiency

82% (100 VAC) /85% (200 VAC) typ. (at 100% load)

Input conditions

Rated input current

3.9 A max. (100 VAC)/ 1.8 A max. (200 VAC)

Output conditions

Rated output voltage

24 VDC

Rated output current

12.5 A

Protection

Overvoltage protection

15.6 A or more *2

Activates at 26.4 V or more. Voltage interruption method, recovers when input is applied again. *3

Applicable standards

Safety standards

UL: UL508, UL60950-1
C-UL: CSA C22.2 No.14, CSA C22.2 No.60950-1
EN: EN62368-1, EN50178
IEC: IEC62368-1

EMC standard

FCC Part15B ClassA, EN55011 ClassA, EN61000-6-2

Environmental resistance

Ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Relative humidity

85%RH or less (No condensation)

Storage temperature

-20 to +70 °C -4 to +158 °F (No freezing)

Weight

Approx. 1540 g 3.40 lb

*1 When applying for safety standards, the rated input voltage was 100 to 240 VAC and the rated frequency was 50/60 Hz.
*2 Constant current drop method, automatic recovery.
*3 To recover, turn off the input power supply, leave it off for 1 minute or more, and then turn it on again.

keyence Stock Image
Keyence LJ-GC10 Keyence
Sale price $525.00
Only 2 units left

Specifications

Model

LJ-GC10

Type

Cable between the head and controller

Applicable product

LK-G3000 series

Number included

1

Cable end

Straight

Length

10 m 32.81'

Weight

Approx. 750 g

keyence Stock Image
Keyence LJ-H1W Keyence
Sale price$0.00
Sold Out

Specifications

Model

LJ-H1W

Type

Setup Support Software

Operating System

Windows 11 Pro
Windows 10 *1
Windows 7 (SP1 or later)*2
Windows Vista (SP2 or later)*3
Windows XP (SP3 or later)*4

CPU

Pentium III 400 MHz or higher

Memory capacity

128 MB or more

Available hard disk space

30 MB or more

Display

XGA (1024 x 768 pixels) or greater, 256 colors or greater

PC interface

Includes one of the following*5:
USB 2.0/1.1*6, Ethernet*7, RS-232C (Serial port)

*1 Home, Pro, and Enterprise editions each are supported.
*2 Home Premium, Professional, and Ultimate editions each are supported.
*3 Ultimate, Business, Home Premium, and Home Basic editions each are supported.
*4 Professional and Home Edition editions each are supported.
*5 Select one for communication. Multiple interfaces cannot be used for communication at the same time.
*6 Operations are not guaranteed when connected through a USB hub.
*7 Operations are not guaranteed when connected through a router or a LAN connection.

Keyence New Stock Image
Keyence LJ-G200 Keyence
Sale price $2,945.29
Only 9 units left

Specifications

Model

LJ-G200

Mounting

Diffuse reflective

Reference distance

200 mm 7.87"

Measuring range

Z-axis (Height)

±48 mm ±1.89"

X-axis (Width)

Near

51 mm 2.01"

Reference distance

62 mm 2.44"

Far

73 mm 2.87"

Light source

Type

Red semiconductor laser

Wavelength

655nm (Visible light), Class 2 laser product (JIS C6802)

Output

0.95 mW

Laser Class

Class II Laser Product (FDA (CDRH) 21CFR PART1040.10), Class 2 Laser Product (IEC 60825-1)

Spot shape (at reference distance)

Approx 180 µm x 70 mm
0.007087" x 2.76"

Repeatability

Z-axis (Height)

2 µm 0.000079"*1

X-axis (Width)

20 µm 0.000788"*2

Linearity Z-axis (Height)

±0.1% of F.S.*3

Sampling cycle (trigger interval)

3.8 ms*4

Temperature characteristics

0.02% of F.S./°C

Environmental resistance

Enclosure rating

IP67 (IEC60529)

Ambient light

Incandescent lamp or fluorescent lamp: 5,000 lux max.*5

Ambient temperature

0 to +50 °C 32 to 122 °F

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Aluminum

Weight

Approx. 480 g

*1 The value obtained after 64 times averaging at the reference distance.The target is KEYENCE standard object. The value is the average of the widths in the Height mode.
*2 The value obtained after 64 times averaging at the reference distance.The target is ø10 mm ø0.39" pin gauge. The value is the edge in the Position mode after 16 times of the Smoothing.
*3 The target is KEYENCE standard object. The value is the average of the widths in the Height mode.
*4 With initial setting, minimum measuring range, and single smoothing processing
*5 The illumination on the receiver of the sensor head when targeting an illuminated white paper.

keyence Stock Image
Keyence LJ-S640 Keyence
Sale price$0.00
Sold Out

Specifications

Model

LJ-S640

Reference distance

1116 mm 43.94"*1

Measurement range

Z-axis (height)

+180/−250 mm +7.09"/−9.84" (F.S.=430 mm 16.93")

X-axis (width)

NEAR side

579 mm 22.80"

Reference distance

640 mm 25.20"

FAR side

Y-axis

Reference distance

XY data interval

200 μm 0.0079"

Number of XY data points

3200×3200

Light source

Laser light source

405 nm (visible light) wavelength blue semiconductor laser

Laser class

Class 2M laser product*2 (IEC 60825-1, FDA (CDRH) Part 1040.10*3)

Output

10 mW

Repeatability

Z-axis (height)

10 μm 0.0004"*4

XY (distance)

25 μm 0.0010"*5

Linearity

Standard area

±0.058% of F.S.*6

High-accuracy area

±0.023% of F.S.*6

Imaging time

Min. 0.3 sec *7

I/F

Ethernet

1000BASE-T, 100BASE-TX

Input

LASER_ON, TRG, MEM_CLEAR *8

Output

READY, EXPOSURE_BUSY, ERROR *8

Ratings

Power voltage

24 VDC +25%, -20%

Current consumption / Power

Max. 5.5 A (at 19.2 V), 4.4 A (at 24 V)*9 / Typ. 17 W

Environmental resistance

Enclosure rating

IP65 (IEC60529) *10

Ambient light

Incandescent lamp: 10000 lux or less *11

Ambient temperature

0 to +45°C 32.0°F to +113.0°F *12

Relative humidity

85% RH or below (no condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.033 G2/Hz; X, Y, and Z directions (IEC 60068-2-64)

Shock resistance

15 G (IEC 60068-2-27)

Material

Aluminum

Weight

Approx. 4300 g 9.48 lb

*1 The reference distance is the distance from the bottom edge of the head to the measurement center of the Z-axis (height). See the Dimensions section for the installation reference plane.
*2 Do not view the beam directly using optical instruments (such as eye loupes, magnifiers, microscopes, telescopes, or binoculars). Observing the laser output using optical instruments is dangerous and may damage the eyes.
*3 Laser classification performed based on IEC60825-1 in accordance with FDA (CDRH) Laser Notice.
*4 The measured target is a KEYENCE standard target. Sigma value when the average height of 200 × 200 points in the center of the field of view is measured using the height tool with reciprocating imaging OFF.
*5 The measured target is a KEYENCE standard target. Sigma value when the distance between two circles of 500 points in diameter set 1000 points apart at the center of the field of view on a grayscale image is measured using the circle and circle distance tool with reciprocating imaging OFF.
*6 The measured target is a KEYENCE standard target. Value when the average height of 200 × 200 points is measured using the height tool with reciprocating imaging OFF. See the Dimensions section for the high-accuracy area reference plane.
*7 With YZ range minimum and Y skipping maximum.
*8 Laser ON input is enabled only when connected to a controller.
*9 The maximum value may be exceeded when extreme acceleration is applied.
*10 With an OP cable connected.
*11 When measuring white paper, illuminance on the sensor head receiving surface when light is applied to white paper.
*12 The head needs to be mounted to a metal plate to be used.

Keyence New Stock Image
Keyence LJ-G080 Keyence
Sale price $967.65
In stock, 15 units

Specifications

Model

LJ-G080

Mounting

Diffuse reflective

Reference distance

80 mm 3.15"

Measuring range

Z-axis (Height)

±23 mm ±0.91"

X-axis (Width)

Near

25 mm 0.98"

Reference distance

32 mm 1.26"

Far

39 mm 1.54"

Light source

Type

Red semiconductor laser

Wavelength

655nm (Visible light), Class 2 laser product (JIS C6802)

Output

0.95 mW

Laser Class

Class II Laser Product (FDA (CDRH) 21CFR PART1040.10), Class 2 Laser Product (IEC 60825-1)

Spot shape (at reference distance)

Approx 80 µm x 46 mm
0.003150" x 1.81"

Repeatability

Z-axis (Height)

1 µm 0.000040"*1

X-axis (Width)

10 µm 0.000394"*2

Linearity Z-axis (Height)

±0.1% of F.S.*3

Sampling cycle (trigger interval)

3.8 ms*4

Temperature characteristics

0.02% of F.S./°C

Environmental resistance

Enclosure rating

IP67 (IEC60529)

Ambient light

Incandescent lamp or fluorescent lamp: 5,000 lux max.*5

Ambient temperature

0 to +50 °C 32 to 122 °F

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Aluminum

Weight

Approx. 350 g

*1 The value obtained after 64 times averaging at the reference distance.The target is KEYENCE standard object. The value is the average of the widths in the Height mode.
*2 The value obtained after 64 times averaging at the reference distance.The target is ø10 mm ø0.39" pin gauge. The value is the edge in the Position mode after 16 times of the Smoothing.
*3 The target is KEYENCE standard object. The value is the average of the widths in the Height mode.
*4 With initial setting, minimum measuring range, and single smoothing processing
*5 The illumination on the receiver of the sensor head when targeting an illuminated white paper.

keyence Stock Image
Keyence LJ-S320 Keyence
Sale price$0.00
Sold Out

Specifications

Model

LJ-S320

Reference distance

470.5 mm 18.52"*1

Measurement range

Z-axis (height)

+100/−120 mm +3.94"/−4.72" (F.S.=220 mm 8.66")

X-axis (width)

NEAR side

243 mm 9.57"

Reference distance

295 mm 11.61"

FAR side

320 mm 12.60"

Y-axis

Reference distance

XY data interval

100 μm 0.0039"

Number of XY data points

3200×3200

Light source

Laser light source

405 nm (visible light) wavelength blue semiconductor laser

Laser class

Class 2M laser product*2 (IEC 60825-1, FDA (CDRH) Part 1040.10*3)

Output

10 mW

Repeatability

Z-axis (height)

5 μm 0.000197"*4

XY (distance)

10 μm 0.0004"*5

Linearity

Standard area

±0.027% of F.S.*6

High-accuracy area

Imaging time

Min. 0.3 sec *7

I/F

Ethernet

1000BASE-T, 100BASE-TX

Input

LASER_ON, TRG, MEM_CLEAR *8

Output

READY, EXPOSURE_BUSY, ERROR *8

Ratings

Power voltage

24 VDC +25%, -20%

Current consumption / Power

Max. 5.5 A (at 19.2 V), 4.4 A (at 24 V)*9 / Typ. 17 W

Environmental resistance

Enclosure rating

IP65 (IEC60529) *10

Ambient light

Incandescent lamp: 10000 lux or less *11

Ambient temperature

0 to +45°C 32.0°F to +113.0°F *12

Relative humidity

85% RH or below (no condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.033 G2/Hz; X, Y, and Z directions (IEC 60068-2-64)

Shock resistance

15 G (IEC 60068-2-27)

Material

Aluminum

Weight

Approx. 3700 g 8.16 lb

*1 The reference distance is the distance from the bottom edge of the head to the measurement center of the Z-axis (height). See the Dimensions section for the installation reference plane.
*2 Do not view the beam directly using optical instruments (such as eye loupes, magnifiers, microscopes, telescopes, or binoculars). Observing the laser output using optical instruments is dangerous and may damage the eyes.
*3 Laser classification performed based on IEC60825-1 in accordance with FDA (CDRH) Laser Notice.
*4 The measured target is a KEYENCE standard target. Sigma value when the average height of 200 × 200 points in the center of the field of view is measured using the height tool with reciprocating imaging OFF.
*5 The measured target is a KEYENCE standard target. Sigma value when the distance between two circles of 500 points in diameter set 1000 points apart at the center of the field of view on a grayscale image is measured using the circle and circle distance tool with reciprocating imaging OFF.
*6 The measured target is a KEYENCE standard target. Value when the average height of 200 × 200 points is measured using the height tool with reciprocating imaging OFF. See the Dimensions section for the high-accuracy area reference plane.
*7 With YZ range minimum and Y skipping maximum.
*8 Laser ON input is enabled only when connected to a controller.
*9 The maximum value may be exceeded when extreme acceleration is applied.
*10 With an OP cable connected.
*11 When measuring white paper, illuminance on the sensor head receiving surface when light is applied to white paper.
*12 The head needs to be mounted to a metal plate to be used.