PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
AP-C33K |
|||
Type |
Positive pressure, NPN |
|||
Rated pressure |
0 to 145.0 Psi |
|||
Fluid type |
Air or non-corrosive gases |
|||
Type of pressure |
Gauge pressure |
|||
Display |
3 1/2-digit, 2-color, 7-segment LED (Character height: 0.43" (11 mm)) Display cycle: 10 times/s |
|||
Operation indicator |
Red LED x 2 (corresponding to control output 1 and 2) |
|||
Display resolution |
Normal mode: 0.2 Psi, Focus mode: 0.02 Psi |
|||
Power consumption |
Normal |
12 V: 720 mW (60 mA) or less, 24 V: 960 mW (40 mA) or less |
||
Eco mode |
12 V: 480 mW (40 mA) or less, 24 V: 720 mW (30 mA) or less |
|||
Display temperature characteristic |
±1 % of F.S. max. |
|||
Hysteresis |
Variable (Standard: 0.5 % of F.S.)*1 |
|||
Response time (Chattering prevention function) |
2.5, 5, 100, or 500 ms (selectable) |
|||
I/O |
Analog output |
1 to 5 V with load impedance of 1 kΩ max. (or zero-shift input selectable) |
||
Zero-shift input |
Input time: 2 ms or more. (or analog output selectable) |
|||
Control output |
NPN open collector 100 mA max. (at 40 V or below) with max. residual voltage of 1 V, 2 outputs (NO or NC selectable) |
|||
Pressure port |
NPT 1/8 180 ° rotation |
|||
Rating |
Power voltage |
12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less |
||
Environmental resistance |
Pressure resistance |
1.5 MPa |
||
Ambient temperature |
0 to 50 °C 32 to 122 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Material |
Front housing: Polysulfone, Rear housing: PBT, Front seat: Polycarbonate, Pressure port: Zinc die-casting |
|||
Accessories |
Power supply cord (6.6' 2-m with connector), Unit seal |
|||
Weight |
Approx. 30 g (without cable) /Approx. 85 g (with 6.6' 2-m cable) |
|||
*1 A standard of 0.2 % of FS applies while in focus mode. | ||||

Specifications
Model |
FL-P160 |
|||
Probe length |
1,600*1 |
|||
Measurement range (dead zone excluded) |
1,565 (1,520)*2 |
|||
Weight |
Approx. 650 g |
|||
*1 Total length including the projected areas of the sensor refer to External Dimension Diagrams for details. Can be shortened up to 100 mm 3.93". | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
FD-GD100U |
|||
Pipe size/Outer diameter |
4" (100 A) ø111 to ø117 mm ø4.37" to ø4.61" |
|||
Weight |
Approx. 0.56 kg |
|||



Specifications
Model |
PR-FB15N1 |
|||
Type |
Reflective (Background suppression) |
|||
Output |
NPN |
|||
Shape |
Flat |
|||
Cable connection |
1 m cable |
|||
Detection distance |
1 to 15 mm 0.04" to 0.59" |
|||
Number of control outputs |
2 outputs |
|||
Output operation |
Output 1 |
Light-ON |
||
Output 2 |
Dark-ON |
|||
Response time |
Output 1 |
0.5 ms |
||
Output 2 |
ON→OFF: 2.7 ms, OFF→ON: 0.5 ms |
|||
Sensitivity adjustment |
None |
|||
Spot diameter |
Approx. 2.5 x 4.5 mm (at 15 mm) |
|||
Light source |
4 element, point light source, red LED (650 nm) |
|||
Mutual interference prevention function |
4 sensors |
|||
Indicator lamp |
Output indicator (orange), stable operation indicator (green), thrubeam type transmitter: power supply indicator (green) |
|||
Control output |
30 VDC or lower, 50 mA or lower |
|||
Protection circuit |
Power supply reverse connection protection, output overcurrent protection, |
|||
Rating |
Power voltage |
10 to 30 VDC, including Ripple (P-P) 10 % |
||
Current consumption |
19 mA |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529), IP69K (DIN40050-9), 4X, 6P, 13 (NEMA250) |
||
Insulation resistance |
20 MΩ or higher (500 VDC) |
|||
Ambient light |
Incandescent lamp: 5,000 lux or lower, Sunlight: 20,000 lux or lower |
|||
Ambient temperature |
-25 to +55 °C -13 to 131 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Storage temperature |
-25 to +75 °C -13 to 167 °F |
|||
Withstand voltage |
1,000 VAC, 50/60 Hz, 1 min |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
1,000 m/s2, 6 times in each of the X, Y, and Z directions |
|||
Material |
Case: SUS316L, indicator cover/lens cover: polysulfone, |
|||
Accessories |
Instruction manual |
|||
Weight |
Approx. 18 g |
|||

Specifications
Model |
SH-305 |
|||
Type |
Standard Shielded Cylindrical |
|||
Shape |
ø5.4×18 Cylindrical |
|||
Detectable object |
Ferrous metal (see Characteristics for nonferrous metals) |
|||
Standard target (iron, t=1 mm 0.04") |
5 x 5 mm 0.20"*1 |
|||
Stable detecting range |
0 to 1 mm 0.04" |
|||
Maximum detecting distance |
3 mm 0.12" |
|||
Repeatability |
0.001 mm 0.00004"*1 |
|||
Hysteresis |
0.01 mm 0.0004"*1 |
|||
Temperature characteristics |
0.08%/°C*1 |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Ambient temperature |
-10 to +60 °C 14 to 140 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Weight |
Approx. 45 g |
|||
*1 Above values obtained when the detecting distance is set at 50% of the maximum stable detecting distance. | ||||

Specifications
Model |
OP-35388 |
|||
Overview |
Joint converting M5 male thread to R1/8. |
|||
Applicable product |
AP-41, AP-43, AP-44 |
|||
Material |
Nickel plated brass |
|||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.


Specifications
Model |
FR-LW20 |
|||
Type |
2-wire standard model |
|||
Measuring range |
Up to 20 m 65.6'*1 |
|||
Display range |
Up to 25 m 82.0'*1 |
|||
Measurable dielectric constant of medium |
2 or more*2 |
|||
Resolution |
1 mm 0.04" |
|||
Precision |
Up to 0.1 m 0.3': ±10 mm 0.39"; |
|||
Response time |
1 s, 4 s (default value), 10 s, 25 s |
|||
Tank pressure |
-0.1 to +1 MPa (-0.1 to +0.1 MPa below -20°C -4°F) |
|||
Material |
Tank interior |
Lens: PTFE; |
||
Housing |
PPS PC PA |
|||
Connection diameter |
G1-1/2 (40A) |
|||
Output |
No. of control outputs |
1 |
||
Control output/auxiliary output |
Transistor output (NPN open collector) |
|||
Analog output |
4 to 20 mA (Response time: 3 s after internal value is confirmed [90% response]) |
|||
Network compatibility |
HART |
|||
Analog output accuracy |
Resolution |
1 mm 0.04"*4 |
||
Zero accuracy |
±0.1 mA (zero point = 4 mA)*4 |
|||
F.S. accuracy |
±0.2 mA (full scale = 20 mA)*4 |
|||
Power supply |
Power voltage |
18.3 to 35 VDC. |
||
Power consumption |
752.5 mW or less (including analog output; excluding load current) |
|||
Environmental resistance |
Ambient temperature |
-30 to +60°C -22 to 140°F (no freezing) |
||
Relative humidity |
Up to 85% RH (no condensation) |
|||
Temperature of coupling used |
-30 to +85°C -22 to 185°F (no freezing) |
|||
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2 X, Y and Z directions |
|||
Shock resistance |
100 m/s2 (10 G), 16 ms pulses, 1000 times each in X, Y and Z directions |
|||
Enclosure rating |
IP67 (IEC60529), Enclosure Type 4X (NEMA250) |
|||
Protection circuit |
Reverse power connection protection, power supply surge protection, output short-circuit protection, output surge protection |
|||
Weight |
Approx. 920 g 32.45 oz |
|||
*1 Guaranteed value in water with the recommended installation. In still water, measurement is possible with water up to the edge of the lens. An undetectable area is present at short range due to the environment and measurement medium. The maximum measuring range is also reduced. | ||||

Specifications
Model |
OP-89051 |
|||
Overview |
Tungsten electrode probe. |
|||
Note |
Tungsten electrode probe for SJ-Q (5 supplied) |
|||


PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
SJ-M071C |
|||
Type |
Head |
|||
Voltage application method |
Pulse AC method |
|||
Applied voltage |
±5.5 kV |
|||
Rated output voltage |
±6 kV |
|||
Ion balance control method |
I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Control input |
Static elimination stop input |
Non-voltage input |
||
Control output |
Alarm output |
NPN open collector 100 mA (40 V or less) |
||
Ion level alarm output | ||||
Condition alarm output | ||||
Air purge supplied pressure |
0.2 MPa or less |
|||
Effective length |
324 mm 12.756"*2 |
|||
Total length |
380 mm 14.961"*3 |
|||
Rating |
Power voltage |
24 VDC ±10 % |
||
Current consumption |
450 mA or less |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||
Relative humidity |
35 to 65 % RH (No condensation) |
|||
Weight |
Approx. 720 g |
|||
*1 Operating distance: 50 mm 1.96" (50 Hz), 600 mm 23.62" (8 Hz), 1,500 mm 59.05" (1 Hz). Downward air flow: 0.3 m/s. Air purge: None | ||||