Machine Vision Systems

5768 products

Showing 5065 - 5088 of 5768 products

Showing 5065 - 5088 of 5768 products
View
keyence Stock Image
Keyence S-P12 Keyence
Sale price$0.00
Sold Out

Specifications

Model

S-P12

Type

Tough mounting bracket

Applicable product

PZ2 Series

Number included

1 unit

keyence Stock Image
Keyence GL-VP2 Keyence
Sale price$0.00
Sold Out

Specifications

Model

GL-VP2

Type

Main unit connection cable

Number included

1 pc.

Cable end

Female side: M12 connector 5 pin
Male side: Strand wire, 5-core

Number of cores

5

Length

2 m 6.6'

Material

connector: PVC/Nickel-plated brass
cable: PVC

Weight

130 g

Keyence Stock Image
Keyence DL-EC1A Keyence
Sale price $374.06
Only 9 units left

Specifications

Model

DL-EC1A

Ethernet
specifications

Compliant standards

IEEE802.3u (100BASE-TX)

Transmission speed

100 Mbps (100BASE-TX)

Transmission interface

Category 5e or higher STP cable

Distance between
nodes

100 m 3937.01'

Communication port

RJ-45 x 2

EtherCAT
communication
specifications

Compatible functions

Process data object communication (cyclic communication)
Mailbox communication (message communication) CoE compatible
Explicit Device Identification

Conformance test
version

Complies with V2.0.42

Sensor
connection
specifications

Connectable
sensors

Sensor amplifiers with D-bus support*1

Number of
connectable
sensor units

15 units max.*2

Indicator lamps

Power indicator (PWR): Green LED
RUN indicator (RUN): Green LED
ERR indicator (ERR): Red LED
Sensor communication indicator (D-bus): 2-color (green/red) LED
Link/activity indicator: Green LED

Power voltage

20 to 30 VDC, including ripple (p-p) of 10 %
supplied from the connected sensor amplifiers

Power consumption

2,100 mW or less (at 30 V, 70 mA max.)

Environmental resistance

Pollution degree

2

Ambient temperature

-20 to +55 °C -4 to 131 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Main unit: Polycarbonate

Weight

Approx. 70 g (including connectors)

*1 D-bus is the name of KEYENCE's wiring-saving system for sensor amplifiers.
*2 This varies depending on the connected sensor amplifiers.

keyence Stock Image
Keyence GL-VM06LN Keyence
Sale price$0.00
Sold Out

Specifications

Model

GL-VM06LN

Beam axis spacing/Lens diameter

40 mm 1.57": ø5 ø0.197"

Number of beam axes

6

Total length

240 mm 9.45"

Detection height

200 mm 7.87"

Protection height

285 mm 11.22"

Minimum detectable object size

ø45 mm ø1.77" *1

Detecting distance

0.3 to 15 m 1.0' to 49.2' *2

Effective angular aperture

Up to ±2.5° (3 m 9.8' or above)

Light source

Infrared LED (850 nm)
Exempt Group (IEC62471)

Detection mode

ON when all beam axes received

Synchronization method

Optical synchronization

Interference prevention function

Interference prevention up to 2 units by series connection and switch setting

Control output (OSSD output)

Output type

Transistor output ×2 (PNP/NPN)

Maximum load current

150 mA or less

Residual voltage (when ON)

Up to 2.5 V (with 5 m 16.4' cable)

OFF voltage

Up to 2.0 V (with 5 m 16.4' cable)

Leakage current

Up to 0.8 mA

Maximum load capacity

0.8 μF

Load wiring resistance

Up to 2.5Ω

Protection circuit

Power supply reverse connection protection, short circuit protection for each output, surge protection for each output

Approved standards

EMC

EMS

IEC/EN61496-1, UL61496-1

EMI

EN55011 Class A, FCC Part15B Class A, ICES-003 Class A

Safety

IEC61496-1/EN61496-1, UL61496-1 (Type 4 ESPE)
IEC61496-2/EN61496-2, UL61496-2 (Type 4 AOPD)
EN ISO13849-1 (Category 4, PL e)
IEC61508/EN61508 (SIL3)
UL60947-1 / CSA C22.2 No. 60947-1
UL1998

Response time (OSSD)

With channel 0

ON→OFF

4.1

OFF→ON

45.7 *3

All blocked→ON

51.2 *4

With channel A or B

ON→OFF

10.0

OFF→ON

54.9 *3

All blocked→ON

68.2 *4

Inputs

Short circuit current: Approx. 3 mA

Power supply

Power voltage

24 VDC -20/+25% 10% ripple (P-P) or less, class 2

Current consumption (at maximum) (mA) Indicator : Standard / Eco/ External control

Transmitter

60 *5

Receiver

73 *5

Current consumption (at maximum) (mA) Indicator : OFF

Transmitter

48 *5

Receiver

56 *5

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Ambient light

Incandescent lamp: 3000 lux or less, sunlight: 20,000 lux or less

Operating ambient temperature

-30 to +55°C -22 to +131°F (no freezing) *6

Operating relative humidity

Up to 95%RH (no condensation)

Storage temperature

-30 to +70°C -22 to +158°F (no freezing)

Storage relative humidity

Up to 95% RH

Overvoltage category

ll

Vibration resistance

5 to 150 Hz 1G 10 cycles each in X, Y, and Z axes

Shock resistance

15 G 6 ms pulses 100 times each in X, Y, and Z axes

Material

Main unit case

Aluminum alloy

Upper case/lower case

PPS (GF40%)

Front cover

Polycarbonate, SUS304

Weight

Transmitter

170 g 6.00 oz

Receiver

Total

340 g 12.00 oz

*1 The maximum operating speed of the detected object is 2.0 m 6.6'/s.
*2 When the optional front protection cover is attached to either the transmitter or receiver, the detecting distance is shortened by 0.5 m 1.6'. When attached to both, it is shortened by 1 m 3.3'.
*3 If light blocking time is 80 ms or less, the response time (OFF>ON) will be slowed down to a minimum of 80 ms to ensure that the OSSD remains OFF for 80 ms or more.
*4 “All blocked > ON” is the time it takes for the transmitter and receiver to turn ON from an unsynchronized state (both upper and lower end beam axes are blocked).
Since the reception or blockage of light is determined after the transmitter and receiver are synchronized, the response time is long.
*5 The current of control output (OSSD) is not included.
*6 When the ambient operating temperature is between 50 and 55°C 122°F and 131°F, set the indicator mode to Light OFF mode.

keyence Stock Image
Keyence CA-DQR15 Keyence
Sale price$0.00
Sold Out

Specifications

Model

CA-DQR15

Type

Square Lights (Direct)

LED color

red

Diffusion plate

OP-87042*1

Power consumption

14.4 W*2

Weight

Approx 520 g

*1 The models listed on the left are for a single bar. Four sets are required for the whole square.
*2 Total value of four bars

Keyence New Stock Image
Keyence GL-R08L Keyence
Sale price $809.99
Only 6 units left

Specifications

Model

GL-R08L

Detection capability

ø1.77" ø45 mm

Total length

12.60" 320mm

No. of beam

8

Detection height

11.02" 280mm

Protection height

14.37" 365mm

Beam axis spacing/Lens diameter

40 mm / ø5 1.57" / ø0.20"

Detecting distance

0.66 to 49.21' 0.2 to 15 m*1

Effective aperture angle

Max. ±2.5° (When operating distance is 9.84' 3 m or more)

Light source

Infrared LED (870 nm)

Response time (OSSD) (ms)

Wire synchronization, One-line or
Optical synchronization system (Channel 0)

ON→OFF

6.6

OFF→ON

48.7*2

All blocked→ON

63.1*3

Optical synchronization system
(Channel A or B)

ON→OFF

6.9

OFF→ON

49.1*2

All blocked→ON

64.2*3

Detection mode

Turns on when no interruptions are present in the detection zone

Synchronization between the transmitter and receiver

Optical synchronization or Wire synchronization (Determined by wiring)

Light interference prevention function

Prevents mutual interference in up to two GL-R systems.
Optical synchronization: prevented by Channel A and B with setting switch
Wire synchronization: prevented automatically

Control output
(OSSD output)

Output

2 transistor outputs. (PNP or NPN is determined by the cable type)

Max. load current

500 mA*4

Residual voltage (during ON)

Max. 2.5 V (with a cable length of 16.40' 5 m)

OFF state voltage

Max. 2.0 V (with a cable length of 16.40' 5 m)

Leakage current

Max. 200 µA

Max. capacitive load

2.2 µF

Load wiring resistance

Max. 2.5 Ω

Supplemental output
(Non-safety-related output)

AUX

transistor outputs. (PNP or NPN is determined by the cable type)
Load current: Max. 50 mA, Residual voltage: Max. 2.5 V (with a cable length of 16.40' 5 m)

Error output

Muting lamp output

Incandescent lamp (24 VDC, 1 to 5.5 W)
LED lamp (load current: 10 to 230 mA) can be connected.

External input

When using a PNP output cable

EDM input
Wait input
Reset input
Muting input 1, 2
Override input

ON voltage: 10 to 30 V
OFF voltage: Open or 0 to 3 V
Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only)

When using an NPN output cable

ON voltage: 0 to 3 V
OFF voltage: Open or 10 V or more
Up to the power voltage
Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only)

Power supply

Power voltage

24 VDC ±20%, ripple (P-P) 10% or less, Class 2

Current
consumption
(Max.) (mA)

Transmitter

41

Receiver

68

Protection circuit

Reverse current protection, short-circuit protection for each output, surge protection for each output

Approved standards

EMC

EMS

IEC61496-1, EN61496-1, UL61496-1

EMI

EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA

Safety

IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE)
IEC61496-2, EN61496-2, UL61496-2 (Type 4 AOPD)
IEC61508, EN61508 (SIL3), IEC62061, EN62061 (SIL CL3)
EN ISO13849-1:2015 (Category 4, PLe)
UL508
UL1998

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Overvoltage category

II

Ambient light

Incandescent lamp: 3,000 lux or less., Sunlight: 20,000 lux or less

Operating ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Operating relative humidity

15 to 85 % RH (No condensation)

Storage temperature

-25 to +60 °C -13 to 140 °F (No freezing)

Storage relative humidity

15 to 95 % RH

Vibration resistance

10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions

Shock resistance

100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Material

Main unit case

Aluminum

Upper case/lower case

Nylon (GF 30%)

Front cover

Polycarbonate, SUS304

Weight

Transmitter

430 g

Receiver

440 g

*1 When the option front protection cover is installed on the one of transmitter or receiver, the Operating distance is shorten by 1.64' 0.5 m. When the front covers are installed on both of the transmitter and receiver, the Operating distance is shorten by 3.28' 1.0 m.
*2 If the interruption is present in the detection zone for less than 80 ms, the response time (OFF to ON) will be 80 ms or more to ensure that the OSSD maintains the OFF state for more than 80 ms.
*3 “All blocked” means the situation where the GL-R operates in optical synchronization system and the
transmitter and receiver is not synchronized (top and bottom beam axes are both blocked). In this situation,
the response time is longer because the GL-R synchronizes the transmitter and receiver fi rst and then
determines the clear or blocked.
*4 When the GL-R is used under surrounding air temperatures between 50 to 55°C 122°F to 131°F, the Maximum load current should not exceed 350 mA.

Keyence Stock Image
Keyence FU-1346 Keyence
Sale price$0.00
Sold Out
Buy the Keyence FU-1346 - a genuine Keyence industrial automation component engineered for reliable performance in demanding manufacturing and process control environments. The Keyence FU-1346 is a direct drop-in replacement for existing installations and ships ready for integration.
keyence Stock Image
Keyence GL-VM191FP Keyence
Sale price$0.00
Sold Out

Specifications

Model

GL-VM191FP

Beam axis spacing/Lens diameter

10 mm 0.39": ø4 ø0.16"

Number of beam axes

191

Total length

1920 mm 75.59"

Detection height

1900 mm 74.80"

Protection height

1924 mm 75.75"

Minimum detectable object size

ø14 mm ø0.55" *1

Detecting distance

0.3 to 12 m 1.0' to 39.4' *2

Effective angular aperture

Up to ±2.5° (3 m 9.8' or above)

Light source

Infrared LED (850 nm)
Exempt Group (IEC62471)

Detection mode

ON when all beam axes received

Synchronization method

Optical synchronization

Interference prevention function

Interference prevention up to 2 units by series connection and switch setting

Control output (OSSD output)

Output type

Transistor output ×2 (PNP/NPN)

Maximum load current

150 mA or less

Residual voltage (when ON)

Up to 2.5 V (with 5 m 16.4' cable)

OFF voltage

Up to 2.0 V (with 5 m 16.4' cable)

Leakage current

Up to 0.8 mA

Maximum load capacity

0.8 μF

Load wiring resistance

Up to 2.5Ω

Protection circuit

Power supply reverse connection protection, short circuit protection for each output, surge protection for each output

Approved standards

EMC

EMS

IEC/EN61496-1, UL61496-1

EMI

EN55011 Class A, FCC Part15B Class A, ICES-003 Class A

Safety

IEC61496-1/EN61496-1, UL61496-1 (Type 4 ESPE)
IEC61496-2/EN61496-2, UL61496-2 (Type 4 AOPD)
EN ISO13849-1 (Category 4, PL e)
IEC61508/EN61508 (SIL3)
UL60947-1 / CSA C22.2 No. 60947-1
UL1998

Response time (OSSD)

With channel 0

ON→OFF

11.9

OFF→ON

61.3 *3

All blocked→ON

78.4 *4

With channel A or B

ON→OFF

41.1

OFF→ON

118.8 *3

All blocked→ON

178.6 *4

Inputs

Short circuit current: Approx. 3 mA

Power supply

Power voltage

24 VDC -20/+25% 10% ripple (P-P) or less, class 2

Current consumption (at maximum) (mA) Indicator : Standard / Eco/ External control

Transmitter

187 *5

Receiver

213 *5

Current consumption (at maximum) (mA) Indicator : OFF

Transmitter

66 *5

Receiver

80 *5

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Ambient light

Incandescent lamp: 3000 lux or less, sunlight: 20,000 lux or less

Operating ambient temperature

-30 to +55°C -22 to +131°F (no freezing) *6

Operating relative humidity

Up to 95%RH (no condensation)

Storage temperature

-30 to +70°C -22 to +158°F (no freezing)

Storage relative humidity

Up to 95% RH

Overvoltage category

ll

Vibration resistance

5 to 150 Hz 1G 10 cycles each in X, Y, and Z axes

Shock resistance

15 G 6 ms pulses 100 times each in X, Y, and Z axes

Material

Main unit case

Aluminum alloy

Upper case/lower case

PPS (GF40%)

Front cover

Polycarbonate, SUS304

Weight

Transmitter

1250 g 44.12 oz

Receiver

1260 g 44.47 oz

Total

2510 g 88.60 oz

*1 The maximum operating speed of the detected object is 2.0 m 6.6'/s.
*2 When the optional front protection cover is attached to either the transmitter or receiver, the detecting distance is shortened by 0.5 m 1.6'. When attached to both, it is shortened by 1 m 3.3'.
*3 If light blocking time is 80 ms or less, the response time (OFF>ON) will be slowed down to a minimum of 80 ms to ensure that the OSSD remains OFF for 80 ms or more.
*4 “All blocked > ON” is the time it takes for the transmitter and receiver to turn ON from an unsynchronized state (both upper and lower end beam axes are blocked).
Since the reception or blockage of light is determined after the transmitter and receiver are synchronized, the response time is long.
*5 The current of control output (OSSD) is not included.
*6 When the ambient operating temperature is between 50 and 55°C 122°F and 131°F, set the indicator mode to Light OFF mode.

keyence Stock Image
Keyence CL-P030G Keyence
Sale price$0.00
Sold Out

Specifications

Model

CL-P030G

Type

Optical unit

Head

CL-P030 *1

Reference distance

30 mm 1.18"

Reference measurement range

Measurement range

±3.7 mm ±0.15"

Linearity

±0.81 μm ±0.000032" *2

High precision measurement range

Measurement range

±1.0 mm ±0.04"

Linearity

±0.59 μm ±0.000023" *2

Resolution

0.015 μm 0.000001" *3

Spot diameter

ø38 μm ø0.0015"

Laser class

Optical unit

Class I

Sampling cycle

100/200/500/1000 μs (Adjustable 4-stage)

Environmental resistance

Enclosure rating

Head

IP67 (IEC60529)

Ambient light

Target surface illuminance: 30000 lux (Incandescent lamp)

Ambient temperature

0 to 50°C 32 to 122°F

Relative humidity

85% RH or less (no condensation)

Vibration resistance

Head

10 to 57 Hz, double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axes

Optical unit

10 to 57 Hz, double amplitude 0.3 mm 0.01"; 2 hours each for X, Y, and Z axes

Shock resistance

15 G, 6 ms

Temperature characteristic

Head

0.005% of F.S./°C

Optical unit

0.015% of F.S./°C

Material

Head

Front: SUS, Rear: Aluminum

Optical unit

Polycarbonate

Weight

Head

Approx. 200 g 7.06 oz

Optical unit

Approx. 1600 g 3.53 lb

*1 Sensor head and optical unit are a matched pair. Not cross compatible.
*2 Value measured in displacement mode with KEYENCE reference workpiece (mirrored surface) .
*3 Value measured using 16,384 average cycles with KEYENCE reference workpiece (mirrored surface).

keyence Stock Image
Keyence R-7 Keyence
Sale price$0.00
Sold Out

Specifications

Model

R-7

Type

Reflector

Applicable product

LV Series

keyence Stock Image
Keyence OP-87569 Keyence
Sale price$0.00
Sold Out

Specifications

Model

OP-87569

Cable end

M12 L-shaped type - Loose wires

Length

5 m 16.40'

Material

Covering: PVC, Nut: Nickel plating over zinc die-cast

keyence Stock Image
Keyence GS-71PCSO(3197) Keyence
Sale price$0.00
Sold Out

Specifications

Model

GS-71PCSO(3197)

Lock type

Power-to-lock type

Type

Standard type

Response time

Lock

Lock→Unlock

320 ms*1*2

Unlock→Lock

220 ms*1*2*3

Lock

Locking force (Fzh)

Min. 2,000 N

Alignment tolerance of lock

±2 mm ±0.08"

Mechanical life-span

1 million cycles or more (with door operation speed of 1 m/s)

Acceptable operation frequency

1 Hz*4

Door radius

Min. 250 mm 9.84"

Auxiliary release

Front, back *5

Cascading

Max. 25 units

Control output (OSSD output)

Output

Transistor outputs × 2

Max. load current

Max. 150 mA

Residual voltage (during ON)

Max 2.5 V (with a cable length of 5 m 16.40')

OFF state voltage

Max 2.0 V (with a cable length of 5 m 16.40')

Leakage current

Max. 0.5 mA

Max. capacitive load

2.2 µF

Load wiring resistance

Max. 2.5 Ω

AUX (Non-safety related output)

Output

Transistor output

Number of outputs

1

Max. load current

50 mA

Residual voltage (during ON)

Max 2.5 V (with a cable length of 5 m 16.40')

External input (Short-circuit current)

Safety input

Approx.1.5 mA × 2

Reset/EDM input

-

Lock control input

Approx. 2.5 mA × 1

OSSD operation switching input

-

Applicable Standards (Safety)

EN 61508, IEC 61508(SIL2/SIL3)
EN 62061, IEC62061(SIL CL2/SIL CL3)
EN ISO13849-1: 2015(PLd, Category 2/PLe, Category 4)
EN ISO14119(Type4)
IEC 60947-5-3, EN 60947-5-3
UL 61010-1, CAN/CSA-C22.2 No.61010-1

Protection circuit

Reverse current protection, short-circuit protection and surge protection for each output

Power supply

Power voltage

24 V DC ±20 % (Ripple P-P 10 % or less, Class2)

Power consumption

3.4 W*6

Environmental resistance

Enclosure rating

IP65/67(IEC60529), IP69K(ISO 20653) (TÜV SÜD certified),
Enclosure Type 3/4X/12/13 (NEMA250)

Operating ambient temperature

-20°C to +55C° -4°F to 131°F (No freezing)

Operating relative humidity

5% to 95%RH

Storage temperature

-25°C to +70°C -13°F to 158°F (No freezing)*7

Storage relative humidity

5% to 95%RH

Vibration resistance

10 to 55 Hz, Double amplitude 2.0 mm 0.08", 5 minutes in each of the X, Y, and Z directions (IEC 60947-5-3)

Shock resistance

30 G in X, Y, Z directions 6 times each axis (IEC 60947-5-3)

Material

Sensor main unit

Case

SUS304, PPS, PBT, PAR, PA66, NBR

Lock

Aluminum alloy, Zinc die cast (Nickel chrome plating)

Cable

PVC

Actuator

Case

PPS, PBT, NBR

Lock

Aluminum alloy, SUS303

Weight

Approx. 380 g

*1 Risk time according to IEC60947-5-3 is 150 ms + 2 ms × (number of units cascaded -1).
*2 If the OSSD operation is open/close link mode, Detect→ Not detect: 20 ms + 2 ms × (number of units cascaded -1), Not detect → Detect: 30 ms + 25 ms × (number of units cascaded -1)
*3 430 ms when locked at the same time the actuator is detected.
*4 Acceptable door operation frequency is 3 Hz if the OSSD operation is open/close link mode. In that case, operation distance is Sao(OFF→ ON) = 3 mm 0.12", Sar(OFF→ ON) = 10.5 mm 0.41".
*5 Do not apply excessive torque (0.45N·m or higher).
*6 Power consumption temporarily increases (Max. 10.5 W, Approx. 0.2 s) when the lock control input(s) is(are) turned ON. After that, current consumption will be within the specification.
*7 When stored for a long period of time, please store it at a temperature of 55°C 131°F or lower.

keyence Stock Image
Keyence EV-130F Keyence
Sale price $445.83
Only 4 units left

Specifications

Model

EV-130F

Type

Spatter-resistant/Shielded

Shape

M30

Detecting distance

10 mm 0.39" ±10%

Detectable object

Ferrous metals (see Characteristics for nonferrous metals)

Standard target
(iron, t=1 mm 0.04")

30 x 30 mm 1.18" x 1.18"

Hysteresis

15% max. of detecting distance

Response frequency

250 Hz

Operation mode

N.O.

Temperature characteristics

±10% max. of detecting distance at 23°C 73.4°F,
within -25 to +70°C -13 to +158°F

Control output
(switching capacity)

5 to 200 mA

Protection circuit

Reversed polarity, short-circuit, surge voltage

Cable length

2 m 6.6'

Rating

Power voltage

12 to 24 VDC, Ripple (P-P) 20 % or less

Current consumption (leakage
current)

Current consumption (leakage current): 1.0 mA max., Residual voltage: 3.6 V max. (with 2-m 6.6' cable)

Residual voltage

Residual voltage: 3.6 V max. (with 2-m 6.6' cable)

Environmental resistance

Enclosure rating

IP67

Ambient temperature

-25 to +80 °C -13 to 176 °F (No freezing)

Relative humidity

35 to 95 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

1,000 m/s2, 3 times in each of the X, Y, and Z directions

Case material

Fluoro-chemical-coated brass

Accessories

Screw nut x 2,
toothed washer x 1

Weight

Approx. 300 g

Keyence New Stock Image
Keyence AP-15S Keyence
Sale price $550.49
Only 5 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-92302 Keyence
Sale price$0.00
Sold Out

Specifications

Model

OP-92302

Type

Super-tough contact

Applicable product

AT Series

keyence Stock Image
Keyence OP-87551 Keyence
Sale price$0.00
Sold Out

Specifications

Model

OP-87551

Overview

Anti-condensation mounting brackets (G3/4) for the FL-001.

Applicable product

FL-001

Material

SUS303

Note

2 gaskets for the FL-001 (OP-87548) are included.

Keyence New Stock Image
Keyence BL-1301HA Keyence
Sale price $471.23
In stock, 13 units
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-88575 Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence LM-1100 Keyence
Sale price$0.00
Sold Out

Specifications

Model

LM-1100

Type

Head

Image sensor

1", 20-mega pixel monochrome CMOS

Display

10.4" LCD monitor (XGA: 1024 × 768)

Receiver lens

Double telecentric lens

Image measurement

Field of view

Wide-field measurement mode

225 mm × 125 mm 8.86" × 4.92"

High-precision measurement mode

206 mm × 106 mm 8.11" × 4.17"

Minimum display unit

0.1 µm

Repeatability

Inside camera's field of view (2σ)

Wide-field measurement mode

±0.5 µm

High-precision measurement mode

±0.1 µm

With stage movement

X/Y axis

±0.9 µm

X/Y plane

Measurement accuracy

Inside camera's field of view (2σ)

Wide-field measurement mode

±2 µm*1

High-precision measurement mode

±0.7 µm*2

With stage movement

X/Y axis (EUX,MPE , EUY,MPE)

±(1.8 + 0.02 L) µm*3

X/Y plane (EUXY,MPE)

±(2.8 + 0.02 L) µm*3

AF height measurement

Repeatability

±2 µm

Measurement accuracy (EUZ,MPE)

±(4.8 + 0.04 L) µm*4

External remote input

Non-voltage input (with and without contact)

External output

OK/NG/FAIL/MEAS.

PhotoMOS output
Rated load 24 V DC, 0.5 A
ON resistance 50 mΩ or lower

Interface

LAN

RJ-45 (10BASE-T/100BASE-TX/1000BASE-T)

USB 3.1

2 ports (rear: 2)

USB 2.0 Series A

4 ports (front: 2, rear: 2)

Monitor output

DVI-D

Record

Hard disk drive

500 GB

Illumination system

Transparent

Telecentric transparent illumination

Ring

Four division, multi-angle illumination (electric)
Slit ring (directivity) illumination (electric)
Telecentric coaxial illumination

External illumination control

Intensity control

PWM control, 100 kHz

Output voltage

12 V DC

Output current

1.6 A (max.)

XY stage

Moving range

200 mm × 100 mm 7.87" × 3.94" (electric)

Withstand load

7 kg

Z stage

Moving range

75 mm 2.95" (electric)

Power supply

Power voltage

100 to 240 V AC ±10% (50/60 Hz)

Power consumption

430 VA or lower

Environmental resistance

Ambient temperature

+10 to 35°C +50 to 95°F*5

Relative humidity

20–80% RH (no condensation)

Overvoltage category

ll

Pollution degree

2

Weight

Approx. 30 kg

*1 In the range of 20 mm × 20 mm 0.79" × 0.79" within the operating ambient temperature range of +23°C ±1°C +73.4°F ±1.8°F at the focused focal point position.
*2 In the range of 5 mm × 5 mm 0.20" × 0.20" within the operating ambient temperature range of +23°C ±1°C +73.4°F ±1.8°F at the focused focal point position
*3 In accordance with ISO10360-7, within the operating ambient temperature range of +23°C ±1°C +73.4°F ±1.8°F at the focused focal point position, and with a load weighing 2 kg or less on the stage (L = amount of X/Y stage movement in mm units)
*4 In accordance with ISO10360-7, within the operating ambient temperature range of +23°C ±1°C +73.4°F ±1.8°F, set to a maximum measurement of 50 mm 1.97" or less, (L = amount of Z stage movement in mm units).
*5 +15 to 35°C +59 to 95°F with X/Y stage travel speed of 80 mm/s.

keyence Stock Image
Keyence KV-CAL16 Keyence
Sale price$0.00
Sold Out

Specifications

Model

KV-CAL16

Focal distance

16 mm 0.63"

F-stop

F1.6 to CLOSE

Minimum working distance

0.4 m 1.3'

Supported cameras

KV-CAC1H/KV-CAC1R

keyence Stock Image
Keyence FU-F38H Keyence
Sale price$0.00
Sold Out

Specifications

Model

FU-F38H

Type

Definite-reflective model

Standard detection object

Mirrored surface with a reflectivity of approximately 98%

Detection distance

TERA

0.3 to 2.3 mm 0.0118" to 0.0906"*1

MEGA

ULTRA

0.3 to 2.2 mm 0.0118" to 0.0866"*1

SUPER

0.4 to 2.0 mm 0.0157" to 0.0787"*1

TURBO

0.5 to 1.8 mm 0.0197" to 0.0709"*1

FINE

0.6 to 1.6 mm 0.0236" to 0.0630"*1

HSPD

*1

S-HSPD

Minimum bend radius

Fiber cable

R4 mm R0.14" or more

Film fiber

No bending*2

Tightening torque

Tip detector/relay case

4.3 cN•m (M1.6)

Length

Fiber cable

Approx. 1000 mm 39.37" (free-cut)

Film fiber

Approx. 131 mm 5.16"

Environmental resistance

Ambient temperature

5°C to 60°C 41°F to 140°F
Up to 70 mm 2.76" from film fiber unit end:
5°C to 105°C 41°F to 221°F*3*4*5

Relative humidity

35 to 85% RH (No condensation)

Material

Fiber cable

Fiber coating: Polyethylene, Fiber core: Acrylic

Relay case

PC, SUS304

Film fiber

Polyimide, Special optical resin, SUS304

Accessories

Fiber cutter, FU adapter, Usage Precautions sheet

Weight

Approx. 3 g

*1 Values are for FS-N40 Series devices with standard detectable objects.
*2 Do not fix the fiber in a bent state for use. Temporary bends of R10 mm R0.39" or more are possible during handling (does not apply to tip detector).
*3 Use in dry conditions in temperatures exceeding 60°C 140°F.
*4 The recommended maximum ambient temperature is 90°C 194°F for constant use of a fiber unit in a high-temperature environment.
*5 Contact KEYENCE for use in situations exceeding those listed above.

keyence Stock Image
Keyence OP-88638 Keyence
Sale price$0.00
Sold Out

Specifications

Model

OP-88638

Type

2-axis adjustment mounting bracket (when illumination unit is used)

Weight

Approx. 260 g

keyence Stock Image
Keyence FU-63T Keyence
Sale price$0.00
Sold Out

Specifications

Model

FU-63T*1

Beam emitting direction

Top

Fibre unit length

2 m78.74" free-cut

Fibre unit diameter

ø1.3×2

Minimum bend radius

R25 mm0.984"

Minimum detectable object

Gold wire with a diameter of 0.005 mm0.0002" *2

Environmental resistance

Ambient temperature

-40 to +70 °C -40 to 158 °F

Weight

Approx. 10 g

*1 For details on the detecting distance, see the fiber amplifier catalog.
*2 The minimum detectable object is the value when the detecting distance and sensitivity have been set to their optimal state.

keyence Stock Image
Keyence OP-85584 Keyence
Sale price$0.00
Sold Out

Specifications

Model

OP-85584

Overview

This is a connector cable for the M8 connector sensor. This connector cable is made of polyurethane (PUR), which has excellent oil resistance.

Applicable product

M8 connector sensor

Cable end

M8 L-shaped connector - Loose wire

Length

2 m 6.56'

Material

Cable: Polyurethane (PUR)

Weight

Approx. 65 g

Recently viewed