Machine Vision Systems

5768 products

Showing 433 - 456 of 5768 products

Showing 433 - 456 of 5768 products
View
keyence Stock Image
Keyence GP-M010T Keyence
Sale price $397.50
Only 6 units left

Specifications

Model

GP-M010T

Rated pressure

–14.5 to +145.0 PSI
(–0.1 to +1 MPa)

Possible display range

–30.5 to +161.0 PSI
(–0.210 to +1.110 MPa)

Allowable pressure

580 PSI (4 MPa)

Zero-cut pressure value

±0.5% of F.S.

Burst pressure

2176 PSI (15 MPa)

Display resolution

0.15 PSI (0.001 MPa)

Fluid type

Gas or liquid that will not corrode the fluid contact part

Type of pressure

Gauge pressure

Precision

±1.0% of F.S. or less*1

Repeatability

±0.3% of F.S. or less*2

Temperature characteristics

±0.6% of F.S. / 10°C 50°F

Connection port

G3/4 (Changes to R1/8 male, R1/4 male, R3/8 male, G1/4 female, NPT1/8 male, and NPT1/4 male with available adapters.)

Box rotation angle

Maximum 330°

Medium temperature

–20 to +100°C –4 to +212°F (no freezing/condensation)*3*4

Power voltage

10 to 30 VDC, Ripple (P-P): 10% max., Class 2 or LPS

Current consumption

60 mA or less (when 24 V: 30 mA or less; when 12 V: 50 mA or less. Excluding output)*5

Possible display range (temperature)

–32 to +112°C –25.6 to +233.6°F

Display method

4 column digital LED white/Vertical inversion of display is possible

Display resolution (temperature)

0.1°C 32.18°F

Liquid contact temperature measurement accuracy

±3.5°C ±6.3°F (at an ambient temperature of 25°C 77°F)*6

Display method

Status indicator (orange, green, red, blue), output indicator 1 (orange), output indicator 2 (orange), temperature indicator (white), communication indicator (green)

Pressure hysteresis

During hysteresis mode: variable (Hysteresis is the difference between the upper setting value and the lower setting value)
During window mode: fixed (0.5% of F.S.)

Pressure responsiveness

Control output

Selectable from 3 to 5000 ms

Analog output

As above +2 ms (90% response)

Output

Output 1 control output

NPN/PNP open collector (Selectable) 30 V or less,
Output 2 Max. 100 mA Residual voltage for the Main Unit is 1 V or less, N.O./N.C. selectable

Output 2
replacement type

Control output

Analog output

Pressure analog output/temperature analog output (selectable), 4–20 mA; maximum load resistance 260 Ω

Network compatibility

IO-Link*7

Environmental resistance

Enclosure rating

IP67

Ambient temperature

–20 to +80°C –4 to +176°F (no freezing or condensation)*8

Relative humidity

35 to 85% RH (no condensation)*8

Vibration resistance

IEC60068-2-6 20 G (10 to 2000 Hz In each direction of X, Y, Z for 2 hours)

Shock resistance

IEC60068-2-27 50 G (11 ms In each direction X, Y, Z 3 times)

Material
properties

Wetted part

Pressure port: SUSXM7/Diaphragm pressure port: Al2O3/O-Ring: FKM

Other parts

Housing metal portion: SUS304, SUS303; Housing plastic portion: PPSU; Air hole*9: PTFE, nickel-plated brass.

Applicable cable

M12 connector 4 pin

Weight

Approx. 150 g 5.29 oz

*1 This is the value when considering linearity + hysteresis + repeatability in a stable environment of 23°C 73.4°F.
*2 The repeatability, based on consistent conditions, is the difference in the detection points at the time of fluctuations in the repetition.
*3 When the temperature of the piping exceeds 80°C 176°F, do not connect the cable.
*4 Condensation may cause measurement failure or breakage. To prevent condensation, take the following measures:
• Make sure the ambient temperature is the same or lower than the fluid temperature.
• Use A/C for dehumidification.
• Keep the sensor 30 cm 11.81" or more from the cooling pipe using connective piping.
*5 Consumption current including output is 0.3 A and under.
*6 This is the value when the measured fluid is water and a KEYENCE adapter is used.
*7 IO-Link specification v1.1/COM2 (38.4 kbps) is supported.
*8 See "7" in "Other precautions" on P.13 for measures on preventing condensation.
*9 Only GP-M001T/M010T/M025T

keyence Stock Image
Keyence XG-HL08M Keyence
Sale price $4,734.37
Only 7 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence New Stock Image
Keyence SJ-M201 Keyence
Sale price $1,096.88
Only 9 units left

Specifications

Model

SJ-M201

Type

Controller Unit

Voltage application method

Pulse AC method

Applied voltage

±5.5 kV

Rated output voltage

±6 kV

Ion balance control method

I.C.C. method

Static elimination time

0.5 sec max. *1

Ion balance

±15 V or less *2

Supply pressure range

0.001 to 0.5 MPa *3

Control input

Static elimination stop input

Non-voltage input

Control output

Alarm output

NPN open c ollector 100 mA (40 V or less)

Ion level alarm output

Condition alarm output

Rating

Power voltage

24 VDC ±10 %

Current consumption

450 mA or less

Environmental resistance

Ambient temperature

0 to +40 °C 32 to 104 °F

Relative humidity

35 to 65 % RH

Weight

Approx. 300 g

*1 At installation distance 50 mm 1.97", air flow 60 Nl/min (ambient temperature 20 to 30°C 68 to 86°F, relative humidity 40 to 60%)
*2 Values obtained at an installation distance of 50 mm 1.97"
and air flow rate of 20 Nl/min [ambient operating temperature
+20 to +30°C +68 to +86°F, ambient operating humidity 40
to 60% RH] (without nozzle)
*3 Inquire for derating of humidity/pressure in environments exceeding
+35°C 95°F. Use clean or dry air at a temperature of -20°C -4°F or
less. Min. air pressure varies by nozzle used.

keyence Stock Image
Keyence OP-89034 Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence SJ-MS1 Keyence
Sale price$0.00
Sold Out

Specifications

Model

SJ-MS1

Applicable product

SJ-M Series

Keyence Stock Image
Keyence VG-C7R Keyence
Sale price $457.71
Only 1 unit left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

keyence Stock Image
Keyence MD-U2010 Keyence
Sale price$0.00
Sold Out

Specifications

Model

MD-U2010

Type

2.5 W type Standard area type Head

Marking laser

Output

3 W/40 kHz (output at contact point: 2.5 W)

Q-switch frequency

CW (continuous oscillation), 40 to 400 kHz

Laser class

Marking laser

YVO4 laser wavelength: 355 nm class 4 laser product (IEC/EN60825-1, JIS C6802, FDA (CDRH) Part 1040.10)*1

Distance measurement laser

Semiconductor laser wavelength: 683 nm output: 5.0 mW class 3R laser product (IEC/EN60825-1, JIS C6802, FDA (CDRH) Part 1040.10)*1

Guide laser

Semiconductor laser wavelength: 655 nm output: 1.0 mW class 2 laser product (IEC/EN60825-1, JIS C6802, FDA (CDRH) Part 1040.10)*1

Marking area

125 × 125 × 42 mm 4.92"×4.92"×1.65"

Standard working distance (±variation width)

189 mm 7.44" (± 21 mm ± 0.83")

Marking method

XYZ 3-axis simultaneous scanning method

Marking method

XY scanner

Digital galvo scanner

Z scanner

Linear motor

Optional models

3D marking

MD-AD-3D

Built-in camera alignment

MD-AD-XYT

Autofocus

MD-AD-ZT

Built-in 2D code reader

MD-AD-2DR/MD-AD-2DRA (corresponding standard ISO/IEC TR 29158 (AIM DPM-1-2006))

Handheld console

MC-P1

Laser safety module

MD-C2BU

PC software

MB-PH1 (Marking Builder Plus/Marking Diagnostic Tool)*2

Built-In Camera

Image sensor

CMOS image sensor (2.3 megapixels)

No. equipped

2 (full-view camera/coaxial camera)

Built-in light source

High-intensity green LED

Built-in power meter

Thermopile

Logging function

Internal operation/terminal block/communication/error/operating information/built-in camera image

Character type

Font

Original Font/User Font/TrueType Font/OpenType Font*3

Barcode

CODE39/ITF/2of5/NW7 (CODABAR)/JAN/CODE128/EAN/UPC-A/UPC-E/CODE93/GS1 DataBar

2D code

QR Code/Micro QR Code/DataMatrix (ECC200/GS1 DataMatrix/DMRE)

Logo image

DXF/BMP/JPEG/PNG/TIFF

Appearance

Plane, 3D shapes (slope, cylinder, cone, sphere, 3DCAD (STL))*4

Work state

Stationary/moving (constant velocity, encoder/rotary marking)

Input / Output

Terminal block input and output/MIL connector input and output/Laser safety module control input and output*5

Interface

RS-232C/USB2.0/Ethernet (100BASE-TX)*6

Marking unit cable length

4.6 ± 0.1 m 15.1' ± 0.3'

Enclosure rating

IP64 (head part)

Environmental resistance

Ambient temperature for transport/storage

-10 to 60°C 14 to 140°F (no freezing)

Ambient temperature

0 to 40°C 32 to 104°F

Ambient temperature for transport/storage

Max. 85% RH (no condensation)

Relative humidity

Weight

Controller: 9.7 kg 21.38 lb
Head: 21.7 kg 47.84 lb
Control cable: 2.5 kg 5.51 lb
Console: 2.0 kg 4.41 lb

Compatible regulations

EU Directives (EMC Directive, Low Voltage Directive, RoHS Directive) / EN Standards (EN61010-1, EN60825-1, EN62471, EN55011, EN61000-6-2, EN63000) / CSA Standards and UL Standards (CAN/CSA C22.2 No. 61010-1, UL61010-1) / North American Standards (FCC Part 15B, ICES-001 Class A) / China RoHS/UKCA

*1 Classification performed based on IEC60825-1 standards in accordance with FDA (CDRH) Laser Notice
*2 Download from the KEYENCE website. Software supported languages: English, Japanese, Chinese (Simplified), Chinese (Traditional), German, Korean, French, Spanish, Thai, Italian
*3 Only TrueType fonts and OpenType fonts with “Installable” or “Editable” font attributes are supported. This attribute can be found in properties at Control Panel - Font.
*4 When using MD-AD-3D
*5 When a laser safety module (MD-C2BU) is installed
*6 The USB ports are USB memory, USB mouse port, barcode reader (A connector) and a dedicated Marking Builder Plus (ActiveX) port (B connector). Supported Ethernet ports include Marking Builder Plus (ActiveX), Operation Monitor, Communication with diagnostic tools and TCP/IP communication, PROFINET, EtherNet/IPTM, EtherCAT®, and FTP client.

Keyence New Stock Image
Keyence IV-150M Keyence
Sale price $1,101.92
In stock, 13 units

Specifications

Model

IV-150M

Type

Short range

Installed distance

50 to 150 mm 1.97" to 5.91"

View

Installed distance 50 mm 1.97": 12 (H) × 9 (V) mm 0.47" (H) × 0.35" (V) to
installed distance 150 mm 5.91": 36 (H) × 27 (V) mm 1.42" (H) × 1.06" (V)

Image sensor

Type

1/3 inch monochrome CMOS

Pixel

752 (H) x 480 (V) 29.61" (H) x 18.90" (V)

Focus adjustment

Manual

Exposure time

1/20 to 1/25,000

Lights

Illumination

Red LED

Lighting method

Pulse lighting/DC lighting is switchable

Tools

Type

Shape Detection, Color Area*1, Area*2, position adjustment

Number

Detection tools: 16 tools, position adjustment tool: 1 tool*3

Switch settings (programs)

32 programs

Image history

Numbers

300 images*4*5

Condition

NG only/All is selectable*5

Analysis information

OFF/Statistics/Histograms is switchable
Statistics: Processing time (latest value, MAX, MIN, AVE), number of OKs, number of NGs, trigger numbers, trigger errors, judgment results list by tools
Histograms: Histogram, matching degree (latest value, MAX, MIN, AVE), numbers of OKs, numbers of NGs*6

Other functions

HDR, HighGain, Color filters*1, Digital zoom*7, Brightness correction, Tilt correction, White balance*1,
Mask outline, Mask area, Test run, ToolAutoTune, Input monitor, Output test, Security settings, Simulator*8

Indicators

PWR/ERR, OUT, TRIG, STATUS, LINK/ACT

Input

Type

Non-voltage input/voltage input is switchable
For non-voltage input: ON voltage 2 V or lower, OFF current 0.1 mA or lower, ON current 2 mA (short circuit)
For voltage input: Maximum input rating 26.4 V, ON voltage 18 V or higher, OFF current 0.2 mA or lower, ON current 2 mA (for 24 V)

Inputs

6 inputs (IN1 to IN6)

Function

IN1: External trigger, IN2 to IN6: Enable by assigning the optional functions
Assignable functions: Program switching, Clear error, External master image registration

Output

Type

Open collector output NPN/PNP is switchable, N.O./N.C. is switchable
For open collector NPN output: Maximum rating 26.4 V 50 mA, remaining voltage 1.5 V or lower
For open collector PNP output: Maximum rating 26.4 V 50 mA, remaining voltage 2 V or lower

Outputs

4 outputs (OUT1 to OUT4)

Function

Enable by assigning the optional functions
Assignable functions: Total judge result, RUN, BUSY, Error, Position adjustment result, Judge result of each tool, Result of the logical operation of each tool

Ethernet

Standard

100BASE-TX/10BASE-T*9

Connector

M12 4pin connector*9

Network function

FTP client, EtherNet/IP™, PROFINET

Rating

Power voltage

24 VDC ±10 % (including ripple)

Current consumption

0.6 A or less

Environmental resistance

Enclosure rating

IP67*10

Ambient temperature

0 to +50 °C 32 to 122 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions*11

Shock resistance

500 m/s2, 3 times in each of 6 directions*11

Material

Main unit case: Aluminium die-casting, Packing: NBR, Front cover: Acrylic, Mounting adapter: POM

Weight

Approx. 270 g

*1 Color type only
*2 Possible with both the Color type and monochrome type
*3 Tools can be installed by programs.
*4 When using the FTP client function: 210 pictures
*5 Saves to the memory in the sensor. The images saved in the sensor can be backed up to the USB memory installed to the intelligent monitor (IV-M30) or to the PC by the software for IV (IV-H1).
*6 This can be displayed on the intelligent monitor (IV-M30) or by software for the IV/IV-G Series (IV-H1).
*7 Possible with both the color type and monochrome type
*8 Simulator can be used with the IV software (IV-H1).
*9 This is for connection with the intelligent monitor (IV-M30) or software for IV (IV-H1).
*10 Except when polarized filter attachment (OP-87436/OP-87437) is mounted
*11 Except when IV-G dome attachment (IV-D10) is mounted

keyence Stock Image
Keyence ER-C18 Keyence
Sale price$0.00
Sold Out

Specifications

Model

ER-C18

Type

M18 Through-Metal cap (×2)

Material

SUS303

Weight

Approx. 35 g
1.24 oz

keyence Stock Image
Keyence CA-DRR13M Keyence
Sale price $4,049.13
Only 5 units left

Specifications

Model

CA-DRR13M

Type

Multi-angle Light (Ring)

LED color

Red

Power consumption

12.5 W

Input voltage

12 VDC

Weight

Approx. 260 g

keyence Stock Image
Keyence GL-SA16S Keyence
Sale price$0.00
Sold Out

Specifications

Model

GL-SA16S

Type

Protection cover Slim type for 16 beam axes

Overview

This protective case protects the main unit from impacts.

Applicable product

GL-S16SH

Number included

1

Length

342.6 mm 13.49"

Material

aluminum

Note

2 each of the following are included: hexagon socket head cap screw (width across flats: 3 mm), washer, and special hexagon socket head cap screw (M4, length: 13 mm, width across flats: 3 mm).

Weight

110 g

keyence Stock Image
Keyence SJ-M030G Keyence
Sale price $2,351.44
Only 5 units left

Specifications

Model

SJ-M030G

Type

Head

Voltage application method

Pulse AC method

Applied voltage

±5.5 kV

Rated output voltage

±6 kV

Ion balance control method

I.C.C. method

Ion balance

±30 V*1

Supply pressure range

0.2 MPa max.

Control input

Static elimination stop input

Non-voltage input

Control output

Alarm output

NPN open-collector, 100 mA max. (40 V max.)

Ion level alarm output

Condition alarm output

Effective length

164 mm 6.46"*2

Total length

220 mm 8.66"*3

Rating

Power voltage

24 VDC ±10%

Current consumption

450 mA max.

Environmental resistance

Ambient temperature

0 to +40°C 32 to +104°F

Relative humidity

35 to 65%RH (no condensation)

Weight

Approx. 600 g

*1 Measured under the following conditions:
[SJ-M030G/M070G]
Air purge: 3 NL/min per electrode
Down flow: 0.3 m/s 0.98 ft/s
Operating distance: 50 mm 1.97"(50 Hz), 600 mm 23.62" (8 Hz), 1500 mm 59.06"(1 Hz)
[SJ-M030C/M070C]
Air purge: None
Down flow: 0.3 m/s 0.98 ft/s
Operating distance: 50 mm 1.97"(50 Hz), 600 mm 23.62" (8 Hz), 1500 mm 59.06"(1 Hz)
*2 Effective length indicates static elimination range at 50 mm 1.97" operating distance.
*3 Overall length includes mounting brackets.

Keyence Stock Image
Keyence CA-CH5RX Keyence
Sale price $1,577.93
Only 3 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence Stock Image
Keyence AP-C30KP Keyence
Sale price $484.37
Only 4 units left

Specifications

Model

AP-C30KP

Type

Multi range, PNP

Rated pressure

Negative pressure mode: 0 to -29.9 inchHg
Positive pressure mode: 0 to 29.5 inchHg
Compound pressure mode: 29.9 to -29.9 inchHg

Fluid type

Air or non-corrosive gases

Type of pressure

Gauge pressure

Display

3 1/2-digit, 2-color, 7-segment LED (Character height: 0.43" (11 mm)) Display cycle: 10 times/s

Operation indicator

Red LED x 2 (corresponding to control output 1 and 2)

Display resolution

Multi range: Negative/Positive 0.1 inchHg, Compound 0.1 inchHg

Power consumption

Normal

12 V: 900 mW (75 mA) or less, 24 V: 1,320 mW (55 mA) or less

Eco mode

12 V: 600 mW (50 mA) or less, 24 V: 960 mW (40 mA) or less

Display temperature characteristic

±1 % of F.S. max.

Hysteresis

Variable (Standard: 0.5 % of F.S.)*1

Response time (Chattering prevention function)

2.5, 5, 100, or 500 ms (selectable)

I/O

Analog output

1 to 5 V with load impedance of 1 kΩ max. (or zero-shift input selectable)

Zero-shift input

Input time: 2 ms or more. (or analog output selectable)

Control output

PNP open collector 100 mA max. (at 30 V or below) with max. residual voltage of 1 V, 2 outputs (NO or NC selectable)

Pressure port

NPT 1/8 180 ° rotation

Rating

Power voltage

12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less

Environmental resistance

Pressure resistance

500 kPa

Ambient temperature

0 to 50 °C 32 to 122 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Front housing: Polysulfone, Rear housing: PBT, Front seat: Polycarbonate, Pressure port: Zinc die-casting

Accessories

Power supply cord (6.6' 2-m with connector)

Weight

Approx. 30 g (without cable) /Approx. 85 g (with 6.6' 2-m cable)

*1 A standard of 0.2 % of FS applies while in focus mode.

Keyence Stock Image
Keyence FD-MA2A Keyence
Sale price $483.12
Only 5 units left
Buy the Keyence FD-MA2A - a genuine Keyence industrial automation component engineered for reliable performance in demanding manufacturing and process control environments. The Keyence FD-MA2A is a direct drop-in replacement for existing installations and ships ready for integration.
keyence Stock Image
Keyence MD-X2520A Keyence
Sale price $94,534.74
Only 1 unit left

Specifications

Model

MD-X2520A

Type

Marking unit (controller + head) 25 W Wide area

Software

MB-PH1 *1 (Marking Builder Plus, Marking Diagnostic Tool)

HMI console

MC-P1

3D function add-in
(sold separately)

MD-AD-3D

XY tracking add-in
(sold separately)

MD-AD-XYT

Z tracking add-in
(sold separately)

MD-AD-ZT

2D code reader add-in
(sold separately)

MD-AD-2DR/MD-AD-2DRA

Marking method

XYZ 3-Axis simultaneous scanning method

Marking laser

YVO4 laser, Class 4 Laser Product (IEC/EN60825-1, JIS C6802, FDA(CDRH) Part 1040.10) *2

Marking laser

Wavelength

1064 nm

Output

25 W

Q-switch frequency

CW (continuous wave), 1 to 400 kHz

Distance laser

Semiconductor laser Wavelength: 683 nm
Output: 5.0 mW
Class 3R laser product
(IEC60825-1, JIS6802, FDA (CDRH) Part1040.10) *2

Guide laser/working distance pointer

Semiconductor laser, wavelength: 655 nm
output: 1.0 mW
Class 2 Laser Product
(IEC60825-1, JIS6802, FDA(CDRH) Part 1040.10) *2

Marking area

330 × 330 × 42 mm 12.99" × 12.99" × 1.65"

Standard working distance
(±variable width)

300 mm (±21 mm) 11.81" (±0.83")

Marking resolution

5 μm

Scan speed

Max. 8000 mm/s 314.96"/s

Character
type

Font

KEYENCE original font (numbers, letters, katakana, hiragana, kanji), user font, TrueType font, OpenType font *3

Barcode

CODE39/ITF/2of5/NW7 (CODABAR)/JAN/CODE128/EAN/UPC-A/UPC-E/CODE93

2D code

QR code, micro QR code, DataMatrix (ECC200/GS1 DataMatrix)

GS1 DataBar

GS1 DataBar/GS1 DataBar CC-A/GS1 DataBar Stacked/GS1 DataBar Stacked CC-A/
GS1 DataBar Limited/GS1 DataBar Limited CC-A/GS1 DataBar Truncated/GS1 DataBar Truncated CC-A

Logo image

Custom character font and logo (CAD) data, BMP/JPEG/PNG/TIFF

Marking
conditions

Workpiece style

Stationary marking, Moving marking (constant, encoder)

Character size (height/width)

0.1 to 330 mm 0.004" to 12.99"

No. of registered jobs

2000 max.

No. of setting blocks

256

Input/output

Terminal block I/O, MIL connector I/O, laser safety module control I/O *4

Interface

RS-232C/USB2.0/Ethernet (100BASE-TX/10BASE-T) *5

Marking head installation direction

All directions

Marking head cable length

4.3 ±0.1 m 14.1' ±0.3'

Cooling method

Forced air cooling

Applicable regulations

EU directives (EMC Directive, Low Voltage Directive, RoHS Directive)/EN standards (EN61010-1, EN60825-1, EN62471, EN55011, EN61000-6-2, EN50581)/
CSA standards and UL standards (CAN/CSA C22.2 No.61010-1, UL61010-1)/North American regulations (FCC Part 15B, ICES-001 Class A)/China RoHS/UKCA

Rated voltage and power consumption

100 to 240 VAC ±10% 50/60 Hz, 850 VA max.

Environmental resistance

Enclosure rating

IP64 (marking head)

Ambient temperature for transport/storage

-10 to 60°C 14 to 140°F (no freezing)

Ambient humidity for transport/storage

30 to 85% (no condensation)

Ambient temperature

0 to 40°C 32 to 104°F

Relative humidity

30 to 85% (no condensation)

Overvoltage category

II

Pollution degree

2

Weight

Controller: 23.0 kg 50.71 lb
Marking head: 13.8 kg 30.42 lb
Console: 2.0 kg 4.41 lb

*1 Download from the KEYENCE website.
Supported operating systems: Windows 11/Windows 10
Languages:English/Japanese/Simplified Chinese/Traditional Chinese/German/Korean/French/Spanish/Thai/Italian.
*2 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice.
*3 The only TrueType and OpenType fonts supported are those fonts whose "Font embeddability" property is set to "Installable" or "Editable." This property can be viewed from the Properties dialog boxes of the fonts shown on the [Fonts] screen in [Control Panel].
*4 Only when the laser safety module (MD-C2A/MD-C2B) is installed.
*5 There are two USB ports: a Type A connector for connecting USB memory devices or a USB mouse and a Type B connector that is the dedicated port for Marking Builder Plus (ActiveX). The Ethernet port supports communication with Marking Builder Plus (ActiveX), TCP/IP communication, EtherNet/IP™ and PROFINET.

Keyence Stock Image
Keyence OP-88655 Keyence
Sale price $203.99
Only 10 units left

Specifications

Model

OP-88655

Type

12-pin power supply cable

Length

5 m 16.4'

Weight

Approx. 300 g

keyence Stock Image
Keyence SJ-Q084 Keyence
Sale price$0.00
Sold Out

Specifications

Model

SJ-Q084

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method / Applied voltage

Pulse AC method/±8000 Vmax

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±3 V *1

Clean rating

ISO14644-1 Class 3 *2

Installation distance

10 mm 0.39" or more

Control input

Static elimination stop input

NPN open collector or non-voltage contact signal

Control output

Ion level warning, condition warning, alarm output

NPN open collector
Maximum 100 mA (40 VDC or less)

Condition alarm output

Alarm output

Communication functions

Remote control

Average power consumption

Normal operation: 8.4 W,
LPC mode: 4.1 W
*3

Major functions

Condition alarm, ion level alarm, alarm output

Air connection port

Rc1/8

Air supply pressure

0.1 to 0.5 MPa 14.50 to 72.52 PSI (recommended air pressure: 0.2 MPa 29.01 PSI)*4

Effective length

920 mm 36.22" *5

Total length

800 mm 31.50"

No. ofelectrodes

13

Rating

Power voltage

24 to 36 VDC±10%

Current consumption

Normal operation: 700 mA or less,
LPC mode: 170 mA (typical)
*3

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

85% RH or less (no condensation)

Material

Electrode probe

Tungsten

Main body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

1120 g 39.53 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81", Air supply pressure: 0.2 MPa 29.01 PSI, Frequency: Highest device driving frequency, Operating ambient temperature: 0 to +40°C 32 to 104°F, Operating ambient humidity: 35 to 65% RH, Measurement position: Bar Center
*2 Contact us for detailed conditions.
*3 24 VDC
*4 If you wish to use the air purge function with intermittent air supply, contact us.
*5 Effective length is for static elimination range when installation distance is 100 mm 3.94".

Keyence Stock Image
Keyence GL-R95F-R Keyence
Sale price $1,567.11
Only 2 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

keyence Stock Image
Keyence ER-GW18N Keyence
Sale price$0.00
Sold Out

Specifications

Model

ER-GW18N

Type

Weld-resistant all-metal shielded type Screw type M18 Cable NPN output

Power supply cable length

2 m 6.6' *1

No. of control outputs

1

Output mode

Output 1

N.O.

Output 2

Button

Available

Button

Function

Distance switching, Through-Metal

Detecting distance

With default settings (Mode 1)

10 mm 0.39" ±10% *2

With distance switching (Mode 2)

5 mm 0.20" ±10% *2

Response frequency

2 Hz *3 *4

Hysteresis distance

15% or less of detecting distance

Detectable object

Magnetic metal, Non-magnetic metal *5

Standard detectable object (Iron, t = 1 mm 0.04")

30 × 30 mm 1.18" × 1.18"

Temperature characteristics

±10% or less of detecting distance at +25°C +77°F (-25 to +55°C -13°F to +131°F)
±20% or less of detecting distance at +25°C +77°F (+55 to +85°C 131°F to 185°F)

Control output

Open-collector, 30 VDC or less; 100 mA or less for 1 output;
100 mA or less in total for 2 outputs

Control output

Residual voltage

NPN output: 0.9 V or less (Output current: 10 mA or less) /
1.4 V or less (Output current: 10 to 100 mA) *6

Power supply

Power voltage

16 to 30 VDC (including 10% or less ripple (P-P)), Class 2

Power consumption (excluding load current)

NPN output: 1040 mW or less (44 mA or less at 24 V, 65 mA or less at 16 V)

Protection circuit

Protection against reverse power connections, output short-circuits, and reverse output connections

Environmental resistance

Enclosure rating

IP67 (IEC60529)

Ambient temperature

-25 to +85°C -13°F to +185°F (no freezing) *7

Relative humidity

Up to 95% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.816 G2 /Hz; X, Y, and Z directions

Shock resistance

1000 m/s2 3280.8 ft/s2 (100 G), 10 times in each of the X, Y, and Z directions

Material

Detecting surface and case: SUS303 with ceramic coating, Button: PBT, Nut: SUS303 with ceramic coating, Toothed lock washer: SUS304
[Connector] Indicator: PBT (M8: LCP), Connector: PBT (M8: LCP)
[Cable] Indicator: TPU, Cable cap (M8 only): PBT, Cable: PVC

Accessories

Nut ×2, Toothed lock washer ×1

Weight

Approx. 110 g 3.88 oz

*1 Ensure the power cable is no longer than 30 m 98.4' for connector types and no longer than 20 m 65.6' with IO-Link connections.
*2 The distance at which a standard detectable object can be detected when the unit is mounted without being affected by surrounding metal.
*3 Value when a standard detectable object is used, the distance between detectable objects is twice the standard detectable object, and the distance to the detectable object is 1/2 the detecting distance.
*4 The response frequency varies depending on the operating temperature. The response frequency at temperatures of +70°C +158°F or higher is 33% of that at +25°C +77°F.
*5 Detecting distance varies according to the material and size. See the characteristic diagrams for details.
*6 Residual voltage is for when a 2 m 6.6' cable is used.
*7 The upper limit of the UL temperature rating is +55℃ +131℉.

Keyence Stock Image
Keyence FD-MH10A Keyence
Sale price $1,051.77
Only 6 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

keyence Stock Image
Keyence MP-FCAS10 Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence CA-E300LJ Keyence
Sale price$0.00
Sold Out

Specifications

Model

CA-E300LJ

Controller

XG-X2902LJ

Head input

2 points *1

Supported heads

LJ-S015/LJ-S025/LJ-S040/LJ-S080/LJ-S160/LJ-S320/LJ-S640

Power supply

Supplied from controller

Environmental resistance

Ambient temperature

0 to +45°C 32 to 113°F (DIN rail mount) / 0 to +40°C 32 to 104°F (base surface mount)

Relative humidity

85% RH or less (no condensation)

Weight

Approx. 560 g 19.77 oz

*1 When two input units are connected, one head can be connected to each unit. In such configurations, the heads can be different models.

keyence Stock Image
Keyence CL-V020 Keyence
Sale price$0.00
Sold Out

Specifications

Model

CL-V020 *1

Type

Sensor head (20 mm vacuum and heatresistant model)

*1 The sensor head and optical unit have been configured as a pair. Specifications can be found on the page relating to the optical unit.

Recently viewed