Specifications
Model |
ER-12N |
|||
Type |
Ultra-long distance shielded type Screw type M12 Cable NPN output |
|||
Power supply cable length |
2 m 6.6' *1 |
|||
No. of control outputs |
1 |
|||
Output mode |
Output 1 |
N.O. |
||
Output 2 |
― |
|||
Button |
Available |
|||
Button |
Function |
Distance switching, Through-Metal |
||
Detecting distance |
With default settings (Mode 1) |
10 mm 0.39" ±10% *2 |
||
With distance switching (Mode 2) |
6 mm 0.24" ±10% *2 |
|||
Response frequency |
With default settings (Mode 1) |
30 Hz *3 *4 |
||
With distance switching (Mode 2) |
100 Hz *3 *4 |
|||
Hysteresis distance |
15% or less of detecting distance |
|||
Detectable object |
Magnetic metal, Non-magnetic metal *5 |
|||
Standard detectable object (Iron, t = 1 mm 0.04") |
30 × 30 mm 1.18" × 1.18" |
|||
Temperature characteristics |
±10% or less of detecting distance at +25°C +77°F (-25 to +55°C -13°F to +131°F) |
|||
Control output |
Open-collector, 30 VDC or less |
|||
Control output |
Residual voltage |
NPN output: 0.9 V or less (Output current: 10 mA or less) / |
||
Power supply |
Power voltage |
16 to 30 VDC (including 10% or less ripple (P-P)), Class 2 |
||
Power consumption (excluding load current) |
1000 mW or less |
|||
Protection circuit |
Protection against reverse power connections, output short-circuits, and reverse output connections |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529) |
||
Ambient temperature |
-25 to +70°C -13°F to +158°F (no freezing) *7 |
|||
Relative humidity |
Up to 95% RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions |
|||
Shock resistance |
1000 m/s2 3280.8 ft/s2 (100 G), 10 times in each of the X, Y, and Z directions |
|||
Material |
Detecting surface: LCP, Mounting screw: SUS303 (M30: SUS304), Case resin: PBT, Button: PBT, Nut: SUS304, Toothed lock washer: SUS304 |
|||
Accessories |
Nut ×2, Toothed lock washer ×1 |
|||
Weight |
Approx. 75 g |
|||
*1 Ensure the power cable is no longer than 30 m 98.4' for connector and connector with pigtail types and no longer than 20 m 65.6' with IO-Link connections. | ||||

Specifications
Model |
IV4-G600CA |
|||
Type |
Wide field of view model |
|||
Installed distance |
From 50 mm 1.97" |
|||
Field of view |
Installation distance 50 mm 1.97": 51 (H) × 38 (V) mm to |
|||
Image receiving element |
Type |
1/2.9 inch color CMOS |
||
Number of pixels |
1280 (H) × 960 (V) |
|||
Focus adjustment |
Auto *1 |
|||
Exposure time |
12 μs to 9 ms *2 |
|||
Lights |
Illumination |
White LED |
||
Lighting method |
Switchable between pulse and continuous lighting |
|||
Indicators |
2 indicators (both displaying same content) |
|||
Power supply |
Average power consumption |
2.5 W (without AI imaging illumination unit installed) |
||
Environmental resistance |
Enclosure rating |
IP67 *3 |
||
Ambient temperature |
0 to +50°C 32 to +122°F (no freezing) *4 |
|||
Relative humidity |
85% RH or less (no condensation) |
|||
Vibration resistance |
Frequency: 10 to 500 Hz; |
|||
Shock resistance |
500 m/s2 1640.4 ft/s2 3 times in each of 6 directions |
|||
Material |
Main unit case: Zinc die-casting. Front cover: Acrylic. Operation indicator cover: TPU *5 |
|||
Weight |
Approx. 75 g 2.65 oz (no AI imaging illumination unit) |
|||
*1 Focus position can be automatically adjusted during installation. It cannot be adjusted while running. Focus position can be registered separately for each program. | ||||

Specifications
Model |
SJ-E132H |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 V |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Installation distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector, Maximum 100 mA (40 VDC or less) |
||
Condition alarm output | ||||
Alarm output | ||||
Communication function |
Remote control communication |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc 1/8 |
|||
Air supply pressure |
0.1 MPa to 0.5 MPa*2 |
|||
Effective length |
1380 mm 54.33"*3 |
|||
Total length |
1280 mm 50.39" |
|||
No. ofelectrodes |
41 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
1550 g 54.67oz |
|||
*1 Measured under the following conditions. | ||||

Specifications
Model |
OP-89140 |
|||
Type |
Standard *1 *2 |
|||
Sensor side |
Connector size |
M12 4-pin |
||
Appearance |
Straight |
|||
Cable connector |
Connector size |
M12 4-pin |
||
Appearance |
Straight |
|||
Length |
2 m 6.6' |
|||
Material |
Cable: PVC, |
|||
Weight |
Approx. 95 g |
|||
*1 Use a heat/cleaning-resistant cable for the weld-resistant all-metal type in environments of 80°C 176°F or higher and for the environment-resistant all-metal type in environments of -25°C -13°F or lower or at 80°C 176°F or higher. | ||||

Specifications
Model |
CA-H035C |
|||
Image element |
Color CMOS, 7×/16× high-speed reading using square-pixel |
|||
Unit cell size |
6.9 µm × 6.9 µm 0.27 Mil × 0.27 Mil |
|||
Valid pixel count |
0.31 megapixel mode: 640 (H) × 480 (V), 0.24 megapixel mode: 512 (H) × 480 (V) |
|||
Image size |
Equivalent to 1/3" |
|||
Scanning system |
Progressive |
|||
Pixel transfer frequency |
At 7× transfer speed: 86 MHz (43 MHz × 2)*1, At 16× transfer speed: 198 MHz*2 |
|||
Transfer system |
Digital serial transfer |
|||
Electronic shutter |
Can be set to 0.05 to 9000 msec by specifying the following numerical inputs: |
|||
Lens mount |
C-mount |
|||
Enclosure rating |
IP64*3 |
|||
Environmental resistance |
Ambient temperature |
0 to 50°C 32 to 122°F |
||
Relative humidity |
85% RH or less |
|||
Weight |
Approx. 75 g (not including lens) |
|||
*1 Transfer speed setting: Standard | ||||

Specifications
Model |
NR-TH08 *1 |
|||
Type |
High-accuracy temperature/voltage measurement unit |
|||
Input method |
Floating unbalanced input, channels insulated from each other, CH inputs insulated from other units (PC), |
|||
Number of channels |
Input: 8 *2 |
|||
Measurement cycle |
Fastest sampling cycle: 100 ms (A/D integration time: 2 ms) to 1 h |
|||
A/D converting system |
Delta-sigma method |
|||
A/D resolution |
24 bit |
|||
A/D integration time |
2 ms, 16.7 ms, 20 ms |
|||
Input type |
Voltage: ±50 V, ±10 V, ±5 V, ±1 V, ±0.5 V, ±0.1 V; Thermocouple; K, J, E, T, R, S, B, N, C; |
|||
Measurement range |
±50 V |
Measurable range: −55.00 to +55.00 V |
||
±10 V |
Measurable range: −11.000 to +11.000 V |
|||
±5 V |
Measurable range: −5.500 to +5.500 V |
|||
±1 V |
Measurable range: −1.1000 to +1.1000 V |
|||
±500 mV |
Measurable range: −550.0 to +550.0 mV |
|||
±100 mV |
Measurable range: −110.00 to +110.00 mV |
|||
K |
Measurable range: −100 to +1372°C -148°F to +2501.6°F, −200 to −100°C -328°F to -148°F |
|||
J |
Measurable range: −100 to +1200°C -148°F to +2192°F, −200 to −100°C -328°F to -148°F |
|||
E |
Measurable range: −100 to +1000°C -148°F to +1832°F, −200 to −100°C -328°F to -148°F |
|||
T |
Measurable range: −100 to +400°C -148°F to +752°F, −200 to −100°C -328°F to -148°F |
|||
N |
Measurable range: 0 to 1300°C 32°F to 2372°F |
|||
C |
Measurable range: 1500 to 2315°C 2732°F to 4199°F, 0 to 1500°C 32°F to 2732°F |
|||
R |
Measurable range: 300 to 1768°C 572°F to 3214.4°F, 0 to 300°C 32°F to 572°F |
|||
S |
Measurable range: 300 to 1768°C 572°F to 3214.4°F, 0 to 300°C 32°F to 572°F |
|||
B |
Measurable range: 400 to 600°C 752°F to 1112°F, 600 to 1820°C 1112°F to 3308°F |
|||
Pt100 |
Measurable range: −200 to +660°C -328°F to +1220°F |
|||
JPt100 |
Measurable range: −200 to +510°C -328°F to +950°F |
|||
Reference contact compensation |
Switchable between internal and external (individual unit setting, 0°C 32°F for external) |
|||
Reference contact compensation accuracy |
±0.7°C ±1.3°F (23°C ±2°C 73.4°F ±3.6°F, at input terminal temperature equilibrium) |
|||
Maximum input voltage |
±60 V (rated) |
|||
Input impedance |
Thermocouple, Voltage: 5 V range or lower |
10 MΩ or more |
||
Voltage: 50 V, 10 V range |
Approx. 1 MΩ |
|||
Withstand voltage |
Measurement input terminal - System bus |
1500 VAC (50/60 Hz) for 1 minute |
||
Mutually between measurement input terminals |
120 Vp-p AC/DC |
|||
Input signal source resistance |
Voltage/thermocouple |
2 kΩ or less |
||
Resistance thermometer |
10 Ω or less per line (three lines must be equal) |
|||
Thermocouple burnout |
Wire breakage detected in the thermocouple range by applying 1 μA of current |
|||
Burnout detection frequency |
Detected in the measurement cycle |
|||
Buffer memory |
200k data |
|||
Warm up time |
30 minutes or more*5 |
|||
Rating |
Power consumption |
1.2 W or less |
||
Environmental resistance |
Ambient temperature |
0 to +40°C 32°F to 104°F |
||
Relative humidity |
10 to 85% RH (no condensation) |
|||
Weight |
Approx. 230 g 8.12 oz (including approx. 100 g 3.53 oz for the OP-51582 (NR-TH08 terminal block)) |
|||
*1 The above specifications are the values when zero point adjustment is performed after the warm-up period in an environment with a temperature of 23°C ±3°C 73.4°F ±5.4°F. | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
FU-7F*1 |
|||
Optical axis diameter |
ø1 mm 0.04" |
|||
Size |
M4 |
|||
Fibre unit length |
2 m 6.56', Free-cut |
|||
Fibre unit diameter |
ø2.2 ø0.09" |
|||
Shape |
Threaded |
|||
Minimum bend radius |
R25 mm R0.98" |
|||
Environmental resistance |
Ambient temperature |
-40 to +70 °C -40 to 158 °F |
||
Weight |
Approx. 21 g |
|||
*1 For details on the detecting distance, see the fiber amplifier catalog. | ||||


Specifications
Model |
VS-C2500MX |
|||
Storage |
Internal storage |
7 GB |
||
microSD card (external) |
Max. 64 GB *1 |
|||
Image sensor |
Image size |
1.1" |
||
Pixel size |
2.5 μm 0.10 Mil |
|||
Frame rate |
28 fps |
|||
Lens |
Mount |
C-mount |
||
I/O connection |
Number of inputs |
1 (insulated) |
||
Number of outputs |
3 (insulated) |
|||
Number of inputs/outputs |
2 (insulated) (input and output switched via settings) |
|||
I/F |
Ethernet |
PoE IEEE 802.3at, M12 X cable × 1 |
||
I/O |
1 In/3 Out/2 In, Out M12 A cable × 1 |
|||
Lighting interface |
Dedicated lighting connection interface × 1 |
|||
External media |
microSD card slot × 1 |
|||
Functions |
Output image pixels |
5120 × 5120 |
||
Exposure time |
0.008 msec to 1000 msec |
|||
Image correction functions |
Gain, Offset, Gamma correction, White balance, Fine HDR |
|||
Indicators |
OLED display, Status LED, Ethernet LED (LINK/ACT), SD card access indicator |
|||
Buttons |
Operation buttons × 3 |
|||
Installation support functions |
Angle monitor |
|||
Power supply |
Power voltage |
24 V +25%/−20% or PoE (IEEE802.3at Power Class 4) |
||
Current consumption (camera only) |
0.97 A, 18.7 W (for 19.2 V)/0.78 A, 18.7 W (for 24 V) |
|||
Current consumption (including lighting) |
4.7 A, 89.7 W (for 19.2 V)/3.8 A, 89.7 W (for 24 V) |
|||
Current consumption (With CA-DEx10X connected) |
11.3 A, 216.7 W (for 19.2 V)/9.1 A, 216.7 W (for 24 V) *2 |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529) |
||
Relative humidity |
85% RH or below (no condensation) |
|||
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.05 G2/Hz; X, Y, and Z directions, 0.5 hours (IEC60068-2-64) |
|||
Shock resistance |
50 G, 3 times in each of the 6 directions (IEC60068-2-27) |
|||
Size (H×W×D) |
93.2 mm × 52.6 mm × 66 mm 3.67" × 2.07" × 2.60" |
|||
Case temperature |
0°C to 65°C 32 to 149°F *3 |
|||
Standard certifications |
CE, FCC, NRTL, KC, UKCA |
|||
Material |
Case: Aluminum die-casting, Front cover: Glass *4 |
|||
Weight |
Approx. 420 g 14.83 oz |
|||
*1 Using the configuration software, format the media before use. | ||||

Specifications
Model |
FT-55AWP |
|||
Type |
Panel mounting type |
|||
Power voltage |
12 to 24 VDC, Ripple (P-P)10% max. |
|||
Power |
Normal |
1400 mW (For 12 V), 1600 mW (For 24 V) |
||
Eco mode |
1150 mW (For 12 V), 1350 mW (For 24 V) |
|||
Display method |
4 + 1/two-digit 7-segment LED, dual-display (red/green) display (character height in the upper display (red): 8 mm 0.31", character height in the lower display (green): 5.7 mm 0.22"), Display updating cycle: 10/s |
|||
Operation indicator |
Red LED x 3 (control output1/control output2/timing input indicator) |
|||
Display resolution |
0.2°F or 1.8°F (0.1°C or 1°C) (when using H10/H20/H30), 1.8°F (1°C) (when using H50/H40K/H50K) |
|||
Hysteresis |
Variable |
|||
Response speed |
HSP, 30, 100, 200, 500, 1000, or 5000 ms can be selected (In HSP: 15 ms max.) |
|||
Bank selection |
Pink and Purple wires can be configured for Bank Inputs #1,2 respectively for up to 4 total banks. |
|||
Bank specifications |
Emissivity (valid in temperature mode) and limit settings x 2 can be set for each bank. |
|||
External input |
Timing input |
Input time: 2 ms min. |
||
Bank input |
Input time: 20 ms min. |
|||
Control output |
PNP open collector x 2 channels (N.O./N.C. selectable), 50 mA max. 30 VDC max., residual voltage: 1 V max. |
|||
Analog output |
4 to 20 mA, maximum load resistance: 260 Ω The upper- and lower-limit values of the analog output range can be set optionally. |
|||
Environmental resistance |
Ambient temperature |
-14 to +122°F (-10 to +50°C), No freezing *1 |
||
Relative humidity |
35 to 85%, No condensation |
|||
Vibration resistance |
10 to 55 Hz, double amplitude: 1.5 mm 0.06", 2 hours in each of X, Y, and Z axis directions |
|||
Material |
Main unit, Cover: Polycarbonate, Keycaps: Polyester elastomer, Cable: Vinyl chloride |
|||
Accessory |
Panel mounting bracket, protection cover, power cable, unit cover sticker |
|||
Weight |
Approx. 85g |
|||
*1 Ambient temperature when using the analog output is 14 to 113°F (-10 to 45°C) . | ||||

Specifications
Model |
FU-22 |
|||
Detecting method |
Focused-beam |
|||
Fibre unit length |
50 cm19.685" cannot be cut |
|||
Minimum bend radius |
R25 mm0.984" |
|||
Detection distance |
7 mm0.276"*1 |
|||
Environmental resistance |
Ambient temperature |
-40 to +70 °C -40 to 158 °F |
||
Weight |
Approx. 4 g |
|||
*1 The detecting distance is a value for white mat paper (the standard detection object) detections. | ||||


Specifications
Model |
FD-G25 |
|||
Pipe size |
DN (Diameter Nominal) |
20 A, 25 A |
||
NPS (Nominal Pipe Size) |
3/4", 1" |
|||
Outer diameter of pipe |
ø25 to 29 mm 0.98" to 1.14", ø32 to 36 mm 1.26" to 1.42" |
|||
Pipe thickness |
2.0 to 4.5 mm 0.08" to 0.18" |
|||
Supported pipe materials |
Iron, steel, stainless steel |
|||
Supported fluids |
Air, Nitrogen, other gases*1 |
|||
Fluid temperature |
0 to 60ºC 32 to 140 °F |
|||
Recommended pressure |
0.4 MPa or greater (58 PSI or greater) |
|||
Rated velocity of flow range |
Up to 15 m/s |
|||
Actual flow rate range (typical) |
m3/h |
Pipe size 20 A: 20.00 |
||
L/min |
Pipe size 20 A: 330.0 |
|||
CFM |
Pipe size 20 A: 12.00 |
|||
Standard flow rate range (typical) [CFM] |
20°C 68°F 60 psi 0.41 MPa |
Pipe size 20 A: 56.84 |
||
20°C 68°F 80 psi 0.55 MPa |
Pipe size 20 A: 72.06 |
|||
20°C 68°F 100 psi 0.69 MPa |
Pipe size 20 A: 87.28 |
|||
20°C 68°F 120 psi 0.83 MPa |
Pipe size 20 A: 102.50 |
|||
Display |
QVGA 2.2" LCD color monitor |
|||
Display update cycle |
Approx. 3 Hz |
|||
Display resolution |
Instantaneous flow rate |
0.01 m3/h, 0.1 L/min, 0.001 CFM |
||
Consumption/leakage amount |
0.001 m3, 1 L, 0.1 CF |
|||
Response time |
1.0 s/2.5 s/5.0 s/10.0 s/30.0 s/60.0 s/120.0 s/200.0 s (variable) |
|||
Measurement accuracy |
Between 10 and 100% of F.S. |
±2.0% of RD*2*3*4*5 |
||
Between 1 and 10% of F.S. |
±1.0% of F.S.*2*3*4*5 |
|||
Zero point error |
±0.15% of F.S.*2*6 |
|||
Static leakage repeatability |
±1.0% of RD*4*7 |
|||
Hysteresis |
Variable |
|||
Flow units |
CFM(S), CFM, m3/h (N), m3/h (S), m3/h, L/min (N), L/min (S), L/min |
|||
I/O wiring connection port |
M12 4-pin connector (male) |
|||
Detection mode (switchable) |
ch.1 |
Instantaneous flow mode/area mode/pulse (+) mode/integrated flow mode/warning mode (consump)*8 |
||
ch.2 |
Instantaneous flow mode/area mode/pulse (−) mode/warning mode (leak)/error output mode/analog output/integrated flow reset/flow rate zero input/origin adjustment input*8 |
|||
Standard I/O (switchable) |
Control output (ch.1/ch.2) |
NPN/PNP setting switchable, open collector output 30 VDC or less, max. 100 mA/ch, residual voltage: 2.5 V or less |
||
Analog output (ch.2) |
4 to 20 mA/0 to 20 mA, load resistance: 500 Ω or less |
|||
External input (ch.2) |
Short-circuit current: 1.5 mA or less, input time: 20 ms or more |
|||
Protection circuit |
Power supply reverse connection protection, power supply surge protection, short-circuit protection for each output, surge protection for each output |
|||
Analog input (for volume conversion) |
M8 4-pin connector (female), analog current input (4 to 20 mA), input resistance: 100Ω or less |
|||
Power supplied to pressure sensor |
Supply voltage: Equivalent to voltage applied to the FD-G, Supply current:70 mA or less (analog output of the pressure sensor included) |
|||
Communication interface |
USB |
USB 2.0 |
||
Ethernet |
Standard |
IEEE 802.3u (100BASE-TX) |
||
Transmission rate |
100 Mbps |
|||
Cable |
Category 5 or higher STP (shielded twisted pair) or UTP (unshielded twisted pair) cable |
|||
Connector |
M12 connector (female, D-code) |
|||
Network function |
Modbus TCP, EtherNet/IP™, IO-Link*9 |
|||
Recording capacity |
Consumption amount/ leakage amount |
Approx. 5 years |
||
Events |
100 |
|||
Power supply |
Power voltage |
20 to 30 VDC including 10% ripple (P-P), Class 2 |
||
Power consumption |
350 mA or less at 20 V, 290 mA or less at 24 V, 230 mA or less at 30 V (load current excluded) (analog output of the pressure sensor excluded), |
|||
Environmental resistance |
Enclosure rating |
IP65/67 (IEC 60529)*10 |
||
Ambient temperature |
Detection head: −10 to +60°C 14 to 140°F (no freezing), display unit: −10 to +55°C 14 to 131°F (no freezing) |
|||
Relative humidity |
5 to 85%RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz, power spectral density: 0.816 G2/Hz, XYZ axes |
|||
Shock resistance |
100 m/s2, 16 ms pulse, XYZ axes, 1000 times for each axis |
|||
Material |
Display unit |
Body: PBT + coating, display: PMMA, Power supply port: SUS304-equivalent, Ethernet port: zinc nickel plating |
||
Detection head |
Body: PPS/SUS304, rear surface: rubber |
|||
Mounting/damping bracket |
SUS304 |
|||
Weight |
Approx. 2.2 kg |
|||
*1 The gas must be uniform and capable of transmitting ultrasonic waves. Measurement may be unstable due to the pressure inside of the pipe and the type of gas. | ||||

Specifications
Model |
EV-118MSO (2063) |
|||
Type |
Shielded |
|||
Shape |
M18 |
|||
Detecting distance |
5 mm 0.20" ±10% |
|||
Detectable object |
Ferrous metals (see Characteristics for nonferrous metals) |
|||
Standard target |
18 x 18 mm 0.71" x 0.71" |
|||
Hysteresis |
10% max. of detecting distance |
|||
Response frequency |
350 Hz |
|||
Operation mode |
N.O. |
|||
Temperature characteristics |
±10% max. of detecting distance at 23°C 73.4°F, |
|||
Control output |
5 to 200 mA |
|||
Protection circuit |
Reversed polarity, short-circuit, surge voltage |
|||
Cable length |
500 mm19.685" |
|||
Rating |
Power voltage |
12 to 24 VDC |
||
Current consumption (leakage |
Current consumption (leakage current): 1.0 mA max., Residual voltage: 3.6 V max. (with 2-m 6.6' cable) |
|||
Residual voltage |
Residual voltage: 3.6 V max. (with 2-m 6.6' cable) |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Ambient temperature |
-25 to +80 °C -13 to 176 °F (No freezing) |
|||
Relative humidity |
35 to 95 % RH (No condensation) |
|||
Case material |
Nickel-plated brass |
|||
Weight |
Approx. 95 g |
|||

Specifications
Model |
CC-N1 |
|||
Ethernet |
Number of ports |
4 |
||
Connector |
M12 X-coded 8-pin female connector |
|||
Standard |
100BASE-TX |
|||
Supported protocols |
EtherNet/IP™ *1, PROFINET CC-B *2, and OPC UA server |
|||
Power supply |
Connector |
M12 L-coded 5-pin male connector |
||
Voltage |
24 VDC ±10% |
|||
Current consumption ratings |
Max: 4.5 W, Typ.: 3.6 W |
|||
Others |
Weight |
Approx. 600 g |
||
Size (H × W × D) |
6.94” × 3.17” × 1.71” 176.4 mm × 80.4 mm × 43.4 mm (excluding connector protrusions) |
|||
Enclosure rating |
IP67 |
|||
Material |
Main unit case: Aluminum die-casting |
|||
Storage temperature |
14 to 131°F -10℃ to +55℃ (no freezing) |
|||
Ambient temperature |
32 to 104°F 0℃ to +40℃ |
|||
Operating ambient humidity |
85% RH or less (no condensation) |
|||
Standard certifications |
EU Directives (EMC Directive, Low Voltage Directive, RoHS Directive) / EN61010-1, |
|||
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.05 G2/Hz; |
|||
Shock resistance |
50 G 6 different directions in 3 times (IEC 60068-2-27) |
|||
*1 Supports DLR. | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.



PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
XM-P2000 *1 |
|||
Type |
Probe |
|||
Marker |
No. of markers |
12 |
||
Housing material |
Marker body |
Quartz glass |
||
Probe housing |
PBT plastic |
|||
Light source |
Near-infrared LED (870 nm) |
|||
Applicable stylus |
M5 (Commercially available styluses can be used) |
|||
Camera |
Compact CMOS image sensor |
|||
Status LED |
Green: Measurement possible |
|||
Weight |
Approx. 500 g (including cable) |
|||
*1 Included with XM-2000, XM-T2000, XM-2200, and XM-T2200 models. | ||||