GP-M010T Keyence

Specifications

Model

GP-M010T

Rated pressure

–14.5 to +145.0 PSI
(–0.1 to +1 MPa)

Possible display range

–30.5 to +161.0 PSI
(–0.210 to +1.110 MPa)

Allowable pressure

580 PSI (4 MPa)

Zero-cut pressure value

±0.5% of F.S.

Burst pressure

2176 PSI (15 MPa)

Display resolution

0.15 PSI (0.001 MPa)

Fluid type

Gas or liquid that will not corrode the fluid contact part

Type of pressure

Gauge pressure

Precision

±1.0% of F.S. or less*1

Repeatability

±0.3% of F.S. or less*2

Temperature characteristics

±0.6% of F.S. / 10°C 50°F

Connection port

G3/4 (Changes to R1/8 male, R1/4 male, R3/8 male, G1/4 female, NPT1/8 male, and NPT1/4 male with available adapters.)

Box rotation angle

Maximum 330°

Medium temperature

–20 to +100°C –4 to +212°F (no freezing/condensation)*3*4

Power voltage

10 to 30 VDC, Ripple (P-P): 10% max., Class 2 or LPS

Current consumption

60 mA or less (when 24 V: 30 mA or less; when 12 V: 50 mA or less. Excluding output)*5

Possible display range (temperature)

–32 to +112°C –25.6 to +233.6°F

Display method

4 column digital LED white/Vertical inversion of display is possible

Display resolution (temperature)

0.1°C 32.18°F

Liquid contact temperature measurement accuracy

±3.5°C ±6.3°F (at an ambient temperature of 25°C 77°F)*6

Display method

Status indicator (orange, green, red, blue), output indicator 1 (orange), output indicator 2 (orange), temperature indicator (white), communication indicator (green)

Pressure hysteresis

During hysteresis mode: variable (Hysteresis is the difference between the upper setting value and the lower setting value)
During window mode: fixed (0.5% of F.S.)

Pressure responsiveness

Control output

Selectable from 3 to 5000 ms

Analog output

As above +2 ms (90% response)

Output

Output 1 control output

NPN/PNP open collector (Selectable) 30 V or less,
Output 2 Max. 100 mA Residual voltage for the Main Unit is 1 V or less, N.O./N.C. selectable

Output 2
replacement type

Control output

Analog output

Pressure analog output/temperature analog output (selectable), 4–20 mA; maximum load resistance 260 Ω

Network compatibility

IO-Link*7

Environmental resistance

Enclosure rating

IP67

Ambient temperature

–20 to +80°C –4 to +176°F (no freezing or condensation)*8

Relative humidity

35 to 85% RH (no condensation)*8

Vibration resistance

IEC60068-2-6 20 G (10 to 2000 Hz In each direction of X, Y, Z for 2 hours)

Shock resistance

IEC60068-2-27 50 G (11 ms In each direction X, Y, Z 3 times)

Material
properties

Wetted part

Pressure port: SUSXM7/Diaphragm pressure port: Al2O3/O-Ring: FKM

Other parts

Housing metal portion: SUS304, SUS303; Housing plastic portion: PPSU; Air hole*9: PTFE, nickel-plated brass.

Applicable cable

M12 connector 4 pin

Weight

Approx. 150 g 5.29 oz

*1 This is the value when considering linearity + hysteresis + repeatability in a stable environment of 23°C 73.4°F.
*2 The repeatability, based on consistent conditions, is the difference in the detection points at the time of fluctuations in the repetition.
*3 When the temperature of the piping exceeds 80°C 176°F, do not connect the cable.
*4 Condensation may cause measurement failure or breakage. To prevent condensation, take the following measures:
• Make sure the ambient temperature is the same or lower than the fluid temperature.
• Use A/C for dehumidification.
• Keep the sensor 30 cm 11.81" or more from the cooling pipe using connective piping.
*5 Consumption current including output is 0.3 A and under.
*6 This is the value when the measured fluid is water and a KEYENCE adapter is used.
*7 IO-Link specification v1.1/COM2 (38.4 kbps) is supported.
*8 See "7" in "Other precautions" on P.13 for measures on preventing condensation.
*9 Only GP-M001T/M010T/M025T

Est. delivery between and    
Estimated delivery dates are estimates only. Int'l customers allow a few more days. For more precise delivery estimates, please contact us at support@plc-direct.com. Contact us in advance for expedited shipping options.
Sale price$397.50
1-year warranty
FREE WORDWIDE SHIPPING
Condition:
$0.00
$397.50
$338.34
Ach Direct Debit American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa

Specifications

Model

GP-M010T

Rated pressure

–14.5 to +145.0 PSI
(–0.1 to +1 MPa)

Possible display range

–30.5 to +161.0 PSI
(–0.210 to +1.110 MPa)

Allowable pressure

580 PSI (4 MPa)

Zero-cut pressure value

±0.5% of F.S.

Burst pressure

2176 PSI (15 MPa)

Display resolution

0.15 PSI (0.001 MPa)

Fluid type

Gas or liquid that will not corrode the fluid contact part

Type of pressure

Gauge pressure

Precision

±1.0% of F.S. or less*1

Repeatability

±0.3% of F.S. or less*2

Temperature characteristics

±0.6% of F.S. / 10°C 50°F

Connection port

G3/4 (Changes to R1/8 male, R1/4 male, R3/8 male, G1/4 female, NPT1/8 male, and NPT1/4 male with available adapters.)

Box rotation angle

Maximum 330°

Medium temperature

–20 to +100°C –4 to +212°F (no freezing/condensation)*3*4

Power voltage

10 to 30 VDC, Ripple (P-P): 10% max., Class 2 or LPS

Current consumption

60 mA or less (when 24 V: 30 mA or less; when 12 V: 50 mA or less. Excluding output)*5

Possible display range (temperature)

–32 to +112°C –25.6 to +233.6°F

Display method

4 column digital LED white/Vertical inversion of display is possible

Display resolution (temperature)

0.1°C 32.18°F

Liquid contact temperature measurement accuracy

±3.5°C ±6.3°F (at an ambient temperature of 25°C 77°F)*6

Display method

Status indicator (orange, green, red, blue), output indicator 1 (orange), output indicator 2 (orange), temperature indicator (white), communication indicator (green)

Pressure hysteresis

During hysteresis mode: variable (Hysteresis is the difference between the upper setting value and the lower setting value)
During window mode: fixed (0.5% of F.S.)

Pressure responsiveness

Control output

Selectable from 3 to 5000 ms

Analog output

As above +2 ms (90% response)

Output

Output 1 control output

NPN/PNP open collector (Selectable) 30 V or less,
Output 2 Max. 100 mA Residual voltage for the Main Unit is 1 V or less, N.O./N.C. selectable

Output 2
replacement type

Control output

Analog output

Pressure analog output/temperature analog output (selectable), 4–20 mA; maximum load resistance 260 Ω

Network compatibility

IO-Link*7

Environmental resistance

Enclosure rating

IP67

Ambient temperature

–20 to +80°C –4 to +176°F (no freezing or condensation)*8

Relative humidity

35 to 85% RH (no condensation)*8

Vibration resistance

IEC60068-2-6 20 G (10 to 2000 Hz In each direction of X, Y, Z for 2 hours)

Shock resistance

IEC60068-2-27 50 G (11 ms In each direction X, Y, Z 3 times)

Material
properties

Wetted part

Pressure port: SUSXM7/Diaphragm pressure port: Al2O3/O-Ring: FKM

Other parts

Housing metal portion: SUS304, SUS303; Housing plastic portion: PPSU; Air hole*9: PTFE, nickel-plated brass.

Applicable cable

M12 connector 4 pin

Weight

Approx. 150 g 5.29 oz

*1 This is the value when considering linearity + hysteresis + repeatability in a stable environment of 23°C 73.4°F.
*2 The repeatability, based on consistent conditions, is the difference in the detection points at the time of fluctuations in the repetition.
*3 When the temperature of the piping exceeds 80°C 176°F, do not connect the cable.
*4 Condensation may cause measurement failure or breakage. To prevent condensation, take the following measures:
• Make sure the ambient temperature is the same or lower than the fluid temperature.
• Use A/C for dehumidification.
• Keep the sensor 30 cm 11.81" or more from the cooling pipe using connective piping.
*5 Consumption current including output is 0.3 A and under.
*6 This is the value when the measured fluid is water and a KEYENCE adapter is used.
*7 IO-Link specification v1.1/COM2 (38.4 kbps) is supported.
*8 See "7" in "Other precautions" on P.13 for measures on preventing condensation.
*9 Only GP-M001T/M010T/M025T

Model

GP-M010T

Rated pressure

–14.5 to +145.0 PSI
(–0.1 to +1 MPa)

Possible display range

–30.5 to +161.0 PSI
(–0.210 to +1.110 MPa)

Allowable pressure

580 PSI (4 MPa)

Zero-cut pressure value

±0.5% of F.S.

Burst pressure

2176 PSI (15 MPa)

Display resolution

0.15 PSI (0.001 MPa)

Fluid type

Gas or liquid that will not corrode the fluid contact part

Type of pressure

Gauge pressure

Precision

±1.0% of F.S. or less*1

Repeatability

±0.3% of F.S. or less*2

Temperature characteristics

±0.6% of F.S. / 10°C 50°F

Connection port

G3/4 (Changes to R1/8 male, R1/4 male, R3/8 male, G1/4 female, NPT1/8 male, and NPT1/4 male with available adapters.)

Box rotation angle

Maximum 330°

Medium temperature

–20 to +100°C –4 to +212°F (no freezing/condensation)*3*4

Power voltage

10 to 30 VDC, Ripple (P-P): 10% max., Class 2 or LPS

Current consumption

60 mA or less (when 24 V: 30 mA or less; when 12 V: 50 mA or less. Excluding output)*5

Possible display range (temperature)

–32 to +112°C –25.6 to +233.6°F

Display method

4 column digital LED white/Vertical inversion of display is possible

Display resolution (temperature)

0.1°C 32.18°F

Liquid contact temperature measurement accuracy

±3.5°C ±6.3°F (at an ambient temperature of 25°C 77°F)*6

Display method

Status indicator (orange, green, red, blue), output indicator 1 (orange), output indicator 2 (orange), temperature indicator (white), communication indicator (green)

Pressure hysteresis

During hysteresis mode: variable (Hysteresis is the difference between the upper setting value and the lower setting value)
During window mode: fixed (0.5% of F.S.)

Pressure responsiveness

Control output

Selectable from 3 to 5000 ms

Analog output

As above +2 ms (90% response)

Output

Output 1 control output

NPN/PNP open collector (Selectable) 30 V or less,
Output 2 Max. 100 mA Residual voltage for the Main Unit is 1 V or less, N.O./N.C. selectable

Output 2
replacement type

Control output

Analog output

Pressure analog output/temperature analog output (selectable), 4–20 mA; maximum load resistance 260 Ω

Network compatibility

IO-Link*7

Environmental resistance

Enclosure rating

IP67

Ambient temperature

–20 to +80°C –4 to +176°F (no freezing or condensation)*8

Relative humidity

35 to 85% RH (no condensation)*8

Vibration resistance

IEC60068-2-6 20 G (10 to 2000 Hz In each direction of X, Y, Z for 2 hours)

Shock resistance

IEC60068-2-27 50 G (11 ms In each direction X, Y, Z 3 times)

Material
properties

Wetted part

Pressure port: SUSXM7/Diaphragm pressure port: Al2O3/O-Ring: FKM

Other parts

Housing metal portion: SUS304, SUS303; Housing plastic portion: PPSU; Air hole*9: PTFE, nickel-plated brass.

Applicable cable

M12 connector 4 pin

Weight

Approx. 150 g 5.29 oz

*1 This is the value when considering linearity + hysteresis + repeatability in a stable environment of 23°C 73.4°F.
*2 The repeatability, based on consistent conditions, is the difference in the detection points at the time of fluctuations in the repetition.
*3 When the temperature of the piping exceeds 80°C 176°F, do not connect the cable.
*4 Condensation may cause measurement failure or breakage. To prevent condensation, take the following measures:
• Make sure the ambient temperature is the same or lower than the fluid temperature.
• Use A/C for dehumidification.
• Keep the sensor 30 cm 11.81" or more from the cooling pipe using connective piping.
*5 Consumption current including output is 0.3 A and under.
*6 This is the value when the measured fluid is water and a KEYENCE adapter is used.
*7 IO-Link specification v1.1/COM2 (38.4 kbps) is supported.
*8 See "7" in "Other precautions" on P.13 for measures on preventing condensation.
*9 Only GP-M001T/M010T/M025T

All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.

If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.

In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.

PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.

Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.

PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.

Trusted By

"Fast service for obsolete parts"

Increasingly PLC/ HMI control platforms are becoming obsolete and parts are no longer supported, however PLC Direct had the HMI we needed and fast shipping for our system to get back online!

Buyer at GE Health

"Helping us move projects forward"

With supply chain issues increasingly affecting our business, PLC Direct has been there for us to supply the PLC products we need, when we need it. If they don't have it readily available, they find it and provide it quickly and reliably. This has helped us move forward with several projects that would have otherwise taken us many, many months to complete.

Buyer at E-Merge Systems – A Rockwell Integrator