PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
MP-F20MDP |
|||
Type |
Manual drain cup |
|||
Connection diameter |
NPT1/2 (15A) |
|||
Material |
Polycarbonate |
|||


Specifications
Model |
SV2-B300AS |
|||
General specifications |
Applicable servo amplifier |
SV2-300L2, SV2-500L2 |
||
Rated output |
SV2-300L2: 2.4 kW, SV2-500L2: 2.9 kW |
|||
Rated torque |
SV2-300L2: 15.1 N·m *1 |
|||
Instant maximum torque |
SV2-300L2: 45.1 N·m, SV2-500L2: 54.0 N·m |
|||
Rated current |
SV2-300L2: 19.6 Arms, SV2-500L2: 23.8 Arms |
|||
Instant maximum current |
SV2-300L2: 56 Arms, SV2-500L2: 70 Arms |
|||
Rated rotation speed |
1500 min-1 |
|||
High rotation speed |
3000 min-1 |
|||
Torque constant |
0.848 N·m/Arms |
|||
Rotor moment of inertia |
53.9 ×10-4kg·m2 |
|||
Rated power rating |
SV2-300L2: 42.2 kW/s, SV2-500L2: 64.2 kW/s |
|||
Rated angle acceleration |
SV2-300L2: 2800 rad/s2, SV2-500L2: 3450 rad/s2 |
|||
Excitation method |
Permanent magnet |
|||
Position/speed detection encoder |
Resolution |
22 bits |
||
Type |
Absolute (ABS) type |
|||
Operating environment |
Enclosure rating |
Completely closed, self-cooling, IP67 standard (excluding connector and axis through-hole area) |
||
Operating ambient temperature |
0 to +60°C 32 to 140°F (reduced ratings at +40°C 104°F or more) |
|||
Storage ambient temperature |
-20 to +60°C -4 to +140°F |
|||
Operating/storage ambient temperature |
20 to 80% RH (no condensation) |
|||
Operating atmosphere |
Indoors (no corrosive gas, flammable gas, oil mist, or dust) |
|||
Altitude |
2000 m 6561.7' or less (reduced ratings at 1000 m 3280.8' or more) |
|||
Vibration rank |
V15 |
|||
Vibration resistance |
49 m/s2 160.8'/s2 with servo motor flange surface as reference (up/down, left/right) 24.5 m/s2 80.4'/s2 (forward/backward) |
|||
Impact resistance |
490 m/s2 1607.6'/s2 with servo motor flange surface as reference, 2 times |
|||
Isolation rank |
phase F |
|||
Min. insulation resistance |
500 VDC, 10 MΩ or more with insulation resistance tester |
|||
Isolation voltage tolerance |
1500 VAC for 1 minute |
|||
Approved standards |
UL/CSA standards |
UL1004-1, UL1004-6, CSA C22.2 No.100 |
||
CE marking |
Low-voltage directive |
EN60034-1, EN60034-5 |
||
EMI |
EN55011 Class A, EN61800-3, EN61000-6-4 |
|||
EMS |
EN61800-3, EN61000-6-2 |
|||
North America EMI standard |
FCC Part15 B, ICES-003. Class A |
|||
Allowable load inertia moment |
SV2-300L2: 3 x, SV2-500L2: 5 x |
|||
Approx. weight |
19.5 kg |
|||
Electromagnetic brake specifications |
Capacity |
18.5 W |
||
Rated voltage |
24 VDC +10%/-0% |
|||
Rated current (@20°C 68°F) |
0.77 A |
|||
Holding torque |
43.1 N·m |
|||
Release time |
170 ms *2 |
|||
Operating time |
100 ms *2 |
|||
*1 50 W to 750 W rated torque is continuously allowable with ambient temperatures of 40°C 104°F and 200 × 200 × 6 mm 7.87" × 7.87" × 0.24" (50 W / 100 W) or 250 × 250 × 6 mm 9.84" × 9.84" × 0.24" (200 W to 750 W) mountable aluminum heat sink. | ||||

Specifications
Model |
LS-7601*1 |
|||
Type |
High-performance |
|||
No. of connectable sensor heads |
2 (fully compatible for all head types) |
|||
Display |
Measurement display |
TFT 5.5-inch LCD display |
||
Minimum display unit |
0.01 µm to 100 µm (7-level selectable) |
|||
Display range |
±99.99999 to ±9,999.9 mm ±3.937" to ±393.7" (Linked to minimum display unit setting, mm/µm selectable) |
|||
Measurement position monitor |
Monitor image (When the measuring head with the monitor function is connected.) |
|||
Tolerance check output display |
5-level LCD indicator |
|||
Input terminal block |
Synchronous 1, 2 input |
Non-voltage input for OUT1 |
||
Auto-zero 1, 2 input | ||||
Reset 1, 2 input | ||||
Statistics 1, 2 input | ||||
Program selection input |
Non-voltage input x 4 inputs |
|||
Output terminal |
Analog voltage output |
±10 V x 2 outputs |
||
Alarm output |
NPN open-collector output (N.C.) |
|||
Total judgment output |
NPN open-collector output for OUT1 |
|||
Comparator ready output | ||||
Strobe 1, 2 output | ||||
Connector I/O |
SUB mode |
Statistical processing output |
NPN open-collector output x 2 outputs*2 |
|
Function output |
Selectable from focus, area check, and differential, NPN open-collector output x 2 outputs*2 |
|||
5-level comparator output |
NPN open-collector output for OUT2*2 |
|||
Comparator ready output | ||||
Strobe output | ||||
BCD mode |
BCD output |
Measurement data output (Sign + 7 digits), OUT1/OUT2 selectable, NPN open-collector output*2 |
||
BCD selection output |
NPN open-collector output*2 |
|||
BCD selection input |
Non-voltage input*2 |
|||
Statistical processing input |
Non-voltage input for OUT2 |
|||
Synchronous input | ||||
Reset input | ||||
Auto-zero input | ||||
Interface |
RS-232C |
Measurement data output and control I/O, printer (Baud rate can be selected up to 115,200 bps.) |
||
Video output |
Conforming to the NTSC system (PIN connector) |
|||
Major functions |
Simultaneous measurement, Area designation, Calculation, Averaging, Calibration, 16-program memory, |
|||
Rating |
Power voltage |
24 VDC ±10 %*3 |
||
Power consumption |
1.2 A max.*3 |
|||
Environmental resistance |
Enclosure rating |
IP64 (Panel surface only) |
||
Ambient temperature |
0 to +40 °C 32 to 104 °F |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Weight |
Approx. 1,010 g |
|||
*1 The rating of the NPN open-collector inside the terminal block is: 100 mA max. (40 V max.), residual voltage of 0.5 V max. | ||||

Specifications
Model |
CA-LA4 |
|||
Focal point |
4.5 mm 0.18" |
|||
F-stop range (aperture) |
F1.6 to F16 |
|||
Minimum WD |
0.05 m 0.16' |
|||
Mount |
C-mount |
|||
Filter size |
M72 × P0.75 |
|||
Compatible image sensor size |
1/1.8" |
|||
TV distortion |
0.20% |
|||
Resolving power |
120 cycles/mm at center, 100 cycles/mm on periphery |
|||
Ambient temperature/humidity range |
0 to +50°C 32 to 122°F, 80% RH or less (No condensation) |
|||
Weight |
Approx. 216 g 7.62 oz |
|||


Specifications
Model |
SK-H050 |
|||
Charge potential measurement |
Measurement mode |
High-precision mode, Wide-range mode |
||
Measuring distance |
High-precision mode |
25 mm 0.98" |
||
Wide-range mode |
100 mm 3.94" |
|||
Measuring range |
High-precision mode |
±2 kV |
||
Wide-range mode |
±50 kV |
|||
Measuring accuracy |
High-precision mode |
±10 V*1 |
||
Wide-range mode |
±100 V*1*2 |
|||
Display resolution |
0 to 999 V : 1 V, 1.00 to 9.99 kV : 0.01 kV. 10.0 kV and higher : 0.1 kV |
|||
Sampling cycle |
Approx 1.4 ms |
|||
Temperature measurement |
Measuring range |
0 to +40℃ 32°F to 104°F |
||
Measuring accuracy |
±1°C 30.2 to 33.8°F*3 |
|||
Display resolution |
0.1°C 32.2°F |
|||
Sampling cycle |
1 s |
|||
Humidity measurement |
Measuring range |
10 to 85% RH |
||
Measuring accuracy |
±5% RH*3 |
|||
Display resolution |
1% RH |
|||
Sampling cycle |
1 s |
|||
Charge monitor function |
Ion balance measuring mode |
Ion balance measuring range |
±1 kV*4 |
|
Measured voltage display resolution |
±10 V*4*5 |
|||
1 V*4 | ||||
Static elimination time measuring mode |
Charge voltage |
±1400 V*4 |
||
Static elimination time display resolution |
0.1 s*4 |
|||
Measuring time |
0 to 99 s*4 |
|||
Laser class |
Class 1 Laser Product (IEC60825-1 : 2014, FDA (CDRH) Part 1040.10*6) |
|||
PC interface |
USB 2.0 Full Speed |
|||
Power supply |
2 AA alkaline dry-cell batteries |
|||
Power supply |
Operating time |
8 hours (in charge potential measuring mode) |
||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F (No freezing or condensation) |
||
Relative humidity |
10 to 85 % RH (No condensation)*7 |
|||
Material |
SK-H050 : PC-ABS, PC, SUS/SK-H055 : PC, SUS, PTFE, PVC |
|||
Weight |
SK-H050: Approx. 240 g, SK-H055: Approx. 220 g |
|||
*1 Within ±100 V when using high-precision mode; within ±1 kV when using wide-range mode. In other ranges, display value has an accuracy of ±10% (display value). Values are obtained from measurements with a response time of 0.8 seconds. | ||||

Specifications
Model |
FU-V84*1 |
|||
Type |
Vacuum-side fiber unit (thrubeam model heat resistant to 350°C 662°F, M4 straight type) |
|||
Detecting method |
Thrubeam |
|||
Fibre unit length |
1 m39.37" |
|||
Minimum bend radius |
R25 mm0.984" or more |
|||
Minimum detectable object |
Opaque material with a diameter of 0.005 mm0.0002" *2 |
|||
Environmental resistance |
Ambient temperature |
-40 to +350 °C -40 to 662 °F |
||
Weight |
Approx. 55 g |
|||
*1 For details on the detecting distance, see the fiber amplifier catalog. | ||||

Specifications
Model |
SJ-H156C |
|||
Type |
HC |
|||
Ion generation method |
Corona discharge |
|||
Structure |
Shock-proof, resistance-coupled |
|||
Voltage application method/applied voltage |
Pulse AC method/±7000 V |
|||
Ion balance control method |
Dual I.C.C. method |
|||
Ion balance |
±30 V *1 |
|||
Cleanliness |
ISO 14644-1 Class 2 *2 |
|||
Operating distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
NPN open collector or non-voltage contact signal |
|||
Control output |
NPN type photorelay, 100 mA max. (at 40 V max.) |
|||
Major functions |
Condition alarm output, ion level alarm output, alarm output |
|||
Air purge connection port |
Rc 1/8 |
|||
Air purge supplied pressure |
0.5 MPa or less *3 |
|||
Effective length |
1560 mm 61.42" *4 |
|||
No. ofelectrodes |
24 |
|||
Static elimination bar length |
1520 mm 59.84" |
|||
Rating |
Power voltage |
24 VDC-36 V±10% |
||
Current consumption |
500 mA (at 24 VDC)/350 mA (at 36 VDC) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32.0°F to 104.0°F |
||
Relative humidity |
35 to 85% RH (No condensation) |
|||
Material |
Electrode probe |
Silicon |
||
Main unit |
ABS resin/PC |
|||
Weight |
Static elimination bar |
1550 g 54.67 oz |
||
*1 Value measured under the following conditions: | ||||

Specifications
Model |
OP-88369 |
|||
Average active efficiency |
89% or more |
|||
Efficiency at low load (10%) |
79% or more |
|||
No-load power consumption |
0.15 W |
|||
Dimensions |
153 × 68 × 35 mm (excluding the cable) |
|||
Rating |
Input |
100 to 240 VAC 50/60 Hz 150 W |
||
Output |
24 VDC, 5 A (120 W max.) |
|||
Weight |
Approx. 650 g (excluding the AC cable) |
|||

Specifications
Model |
KV-N3AM |
|||
Conversion speed |
80 μs/channel *1 |
|||
Conversion |
A/D conversion, D/A conversion |
|||
Points |
A/D conversion : 2 (single end), D/A conversion : 1 |
|||
Range/resolution |
Voltage |
-10 V to +10 V |
A/D conversion : 1/8000 2.5 mV, D/A conversion : 1/8000 2.5 mV *2 |
|
0 to 10 V |
A/D conversion : 1/4000 2.5 mV, D/A conversion : 1/4000 2.5 mV *2 |
|||
0 to 5 V |
A/D conversion : 1/4000 1.25 mV, D/A conversion : 1/4000 1.25 mV *2 |
|||
1 to 5 V |
A/D conversion : 1/3200 1.25 mV, D/A conversion : 1/3200 1.25 mV *2 |
|||
Current |
0 to 20 mA |
A/D conversion : 1/4000 5 μA, D/A conversion : 1/4000 5 μA *2 |
||
4 to 20 mA |
A/D conversion : 1/3200 5 μA, D/A conversion : 1/3200 5 μA *2 |
|||
Conversion precision |
Voltage |
Without temperature |
A/D conversion : |
|
With temperature |
A/D conversion : |
|||
Current |
Without temperature |
A/D conversion : |
||
With temperature |
A/D conversion : |
|||
Input resistance |
Voltage |
A/D conversion : 5 MΩ |
||
Current |
A/D conversion : 250 Ω |
|||
Absolute maximum input |
Voltage |
A/D conversion : ±15 V |
||
Current |
A/D conversion : ±30 mA |
|||
Isolation method |
Between analog input |
Isolated (photocoupler, transformer) |
||
A/D , D/A conversion unit |
Isolation method |
Between Analog input - output |
Non-isolated |
|
Isolation method |
Between analogu input channels |
A/D conversion : Non-isolated |
||
Minimum load resistance |
Voltage |
D/A conversion : 1 kΩ |
||
Maximum load resistance |
Current |
D/A conversion : 600 Ω |
||
Special functions |
▼A/D conversion |
|||
Internal current consumption |
120 mA or less |
|||
Weight |
200 g |
|||
*1 When the temperature fluctuation compensation is used, the temperature fluctuation compensation time of 80 μs will be added regardless of the number of channels being used. | ||||

Specifications
Model |
OP-87625 |
|||
Length |
2 m 6.6' |
|||
Material |
Cable: PVC |
|||
Weight |
Approx. 70 g |
|||

Specifications
Model |
FU-31*1 |
|||
Beam emitting direction |
Side |
|||
Fibre unit length |
2 m78.74" free-cut |
|||
Fibre unit diameter |
ø1.0×2 |
|||
Minimum bend radius |
R10 mm0.394" |
|||
Minimum detectable object |
Gold wire with a diameter of 0.005 mm0.0002" *2 |
|||
Environmental resistance |
Ambient temperature |
-40 to +70 °C -40 to 158 °F |
||
Weight |
Approx. 5 g |
|||
*1 For details on the detecting distance, see the fiber amplifier catalog. | ||||

Specifications
Model |
SJ-E084L |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 V |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Installation distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector, Maximum 100 mA (40 VDC or less) |
||
Condition alarm output | ||||
Alarm output | ||||
Communication function |
Remote control communication |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc 1/8 |
|||
Air supply pressure |
0.1 MPa to 0.5 MPa*2 |
|||
Effective length |
920 mm 36.22"*3 |
|||
Total length |
800 mm 31.50" |
|||
No. ofelectrodes |
13 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
1070 g 37.74oz |
|||
*1 Measured under the following conditions. | ||||

Specifications
Model |
AP-V41AWP |
|||
Type |
Amplifier Unit, PNP |
|||
Applicable sensor head |
AP-41M, AP-41, AP-43, AP-44 |
|||
Set and display range |
-15 to +110 % of F.S.*1 |
|||
Display |
4 1/2-digit, 2-color, 7-segment LED (Character height: 4.5 mm 0.18"), AI indicator (green), Display cycle: 10 times/s |
|||
Operation indicator |
Red LED x 2 (corresponding to control output 1 and 2) |
|||
Repeatability |
±0.2 % of F.S. |
|||
Display resolution |
AP-41M/41/44: Standard mode 0.1 inchHg, High-resolution/Focus mode 0.01 inchHg |
|||
Power consumption |
Normal |
12 V: 720 mW (60 mA) max., 24 V: 960 mW (40 mA) max. |
||
Eco mode |
12 V: 480 mW (40 mA) max., 24 V: 720 mW (30 mA) max. |
|||
Display temperature characteristic |
±1 % of F.S. max. |
|||
Hysteresis |
Variable (Standard: 0.5 % of FS; high-resolution/focus mode: 0.1 % of F.S.) |
|||
Response time (Chattering prevention function) |
1 (in high-speed mode only), 2.5, 5, 100, or 500 ms (selectable) |
|||
I/O |
Analog output |
1 to 5 V with load impedance of 1 kΩ max. (or zero-shift input selectable) |
||
Zero-shift input |
Input time: 2 ms or more. (or analog output selectable) |
|||
Control output |
PNP open collector 100 mA max. (at 30 V or below) with max., residual voltage of 1 V, 2 outputs (NO or NC selectable) |
|||
Rating |
Power voltage |
12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less |
||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F (No freezing) |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Material |
Polycarbonate |
|||
Accessories |
Mounting bracket, Head connector |
|||
Weight |
Approx. 80 g (with 2-m 6.6' cable) |
|||
*1 The focus range applies while in focus mode only. | ||||


Specifications
Model |
CA-DSW7 |
|||
Type |
Back Light |
|||
LED color |
White |
|||
Power consumption |
18 W |
|||
Input voltage |
12 VDC |
|||
Weight |
Approx. 90 g |
|||

Specifications
Model |
MD-F3200 |
|||
Type |
Marking unit (Controller + Head) |
|||
Console (sold separately) |
MC-P1 |
|||
Marking method |
XYZ 3-axis simultaneous scanning method |
|||
Marking laser |
Type |
Yb: Fiber laser (Class 4 laser product; IEC/EN60825-1, JIS C6802, FDA (CDRH) Part 1040.10*1, GB7247.1) |
||
Wavelength |
1090 nm |
|||
Output |
30 W |
|||
Applicable regulations |
EU directive (EMC directive, machinery directive, RoHS directive), |
|||
Pulse frequency |
60 to 120 kHz |
|||
Guide laser/Working distance pointer |
Semiconductor laser, Wavelength: 655 nm, Output: 1.0 mW |
|||
Marking area |
125 × 125 × 42 mm 4.92" × 4.92" × 1.65" |
|||
Standard working distance (±variable width) |
168 mm (±21 mm) 6.61" (±0.83") |
|||
Marking resolution |
2 µm 0.08 Mil |
|||
Scan speed |
Max. 12000 mm/s 472.44"/s |
|||
Character type |
Font |
KEYENCE original font (numbers, letters, katakana, hiragana, kanji), User fonts, True Type fonts |
||
Barcode |
CODE39, ITF, 2of5, NW7 (CODABAR), JAN, CODE128, EAN, UPC-A, UPC-E, CODE93 |
|||
2D code |
QR code, Micro QR code/DataMatrix (ECC200/GS1 DataMatrix) |
|||
GS1 DataBar |
GS1 DataBar, GS1 DataBar CC-A, GS1 DataBar Stacked, GS1 DataBar Stacked CC-A, |
|||
Logo image |
Custom character font and logo CAD data, BMP/JPEG/PNG/TIFF |
|||
Marking conditions |
Workpiece style |
Stationary/moving marking (constant speed/encoder) |
||
Character size (marking height/width) |
0.1 to 125 mm 0.004" to 4.92" |
|||
No. of registered programs |
Max. 2000 programs |
|||
No. of program blocks |
256 blocks |
|||
I/O (Input/output) |
Terminal block I/O, MIL connector I/O |
|||
Interface |
RS-232C, USB 2.0, Ethernet (100BASE-TX/10BASE-T)*2 |
|||
Head installation direction |
All directions |
|||
Head cable length |
4.0 m 13.1' |
|||
Cooling method |
Controller: Forced air cooling, Head: Natural air cooling |
|||
Rated voltage and power consumption |
100 to 120 VAC or 200 to 240 VAC ± 10 %, 50/60 Hz, Max. 550 VA |
|||
Environmental resistance |
Enclosure rating |
IP64 (Head) |
||
Pollution degree |
2 |
|||
Overvoltage category |
II |
|||
Ambient temperature for storage |
-10 to +60 °C 14 to 140 °F (No freezing) |
|||
Ambient temperature |
0 to +40 °C 32 to 104 °F |
|||
Ambient humidity for storage |
30 to 85 % RH (No condensation) |
|||
Relative humidity | ||||
Weight |
Controller: 24.4 kg |
|||
*1 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice. | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
CA-H500CX |
|||
Image element |
Color CMOS, 16× high-speed reading using square-pixel |
|||
Unit cell size |
3.45 µm × 3.45 µm 0.14 Mil × 0.14 Mil |
|||
Valid pixel count |
5 megapixel mode: 2432 (H) × 2040 (V), 2 megapixel mode: 1600 (H) × 1200 (V) |
|||
Image size |
Equivalent to 2/3" |
|||
Scanning system |
Progressive |
|||
Pixel transfer frequency |
195 MHz |
|||
Transfer system |
Digital serial transfer |
|||
Electronic shutter |
Can be set to 0.017 to 100 msec by specifying the following numerical inputs: |
|||
Lens mount |
C-mount |
|||
Environmental resistance |
Ambient temperature |
0 to 40°C 32 to 104°F |
||
Relative humidity |
85% RH or less |
|||
Weight |
Approx. 280 g (not including lens) |
|||

Specifications
Model |
KV-M32G |
|||
Type |
microSD card |
|||
Memory elements |
industrial grade |
|||
Type |
SDHC standard |
|||
Memory capacity |
32 GB |
|||

Specifications
Model |
ER-GL30N |
|||
Type |
General-purpose all-metal shielded type Screw type M30 Cable NPN output Long-Range |
|||
Power supply cable length |
2 m 6.6' *1 |
|||
No. of control outputs |
1 |
|||
Output mode |
Output 1 |
N.O. |
||
Output 2 |
― |
|||
Button |
None |
|||
Button |
Function |
― |
||
Detecting distance |
20 mm 0.79" ±10% *2 |
|||
Response frequency |
30 Hz *3 *4 |
|||
Hysteresis distance |
15% or less of detecting distance |
|||
Detectable object |
Magnetic metal, Non-magnetic metal *5 |
|||
Standard detectable object (Iron, t = 1 mm 0.04") |
60 × 60 mm 2.36" × 2.36" |
|||
Temperature characteristics |
±10% or less of detecting distance at +25°C +77°F (-25 to +55°C -13°F to +131°F) |
|||
Control output |
Open-collector, 30 VDC or less; 100 mA or less for 1 output; 100 mA or less in total for 2 outputs |
|||
Control output |
Residual voltage |
NPN output: 0.9 V or less (Output current: 10 mA or less) / 1.4 V or less (Output current: 10 to 100 mA) *6 |
||
Power supply |
Power voltage |
16 to 30 VDC (including 10% or less ripple (P-P)), Class 2 |
||
Power consumption (excluding load current) |
NPN output: 1040 mW or less (44 mA or less at 24 V, 65 mA or less at 16 V) |
|||
Protection circuit |
Protection against reverse power connections, output short-circuits, and reverse output connections |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529), IP67G (JIS C 0920) |
||
Ambient temperature |
-25 to +70°C -13°F to +158°F (no freezing) *7 |
|||
Relative humidity |
Up to 95% RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions |
|||
Shock resistance |
1000 m/s2 3280.8 ft/s2 (100 G), |
|||
Material |
Detecting surface: SUS303, Mounting screw: SUS303 (M30: SUS304), Case resin: PBT, Nut: SUS304, Toothed lock washer: SUS304 |
|||
Accessories |
Nut ×2, Toothed lock washer ×1 |
|||
Weight |
Approx. 175 g |
|||
*1 Ensure the power cable is no longer than 30 m 98.4' for connector and connector with pigtail types and no longer than 20 m 65.6' with IO-Link connections. | ||||