Specifications
Model |
EX-V01P*1 |
|||
Type |
Amplifier Unit PNP |
|||
Shape |
ø5.4 x 18 mm ø0.21" x 0.71" Cylindrical |
|||
Measuring range |
0 to 1 mm 0.04" |
|||
Display range |
-19,999 to +19,999 |
|||
Linearity |
±0.3% of F.S. |
|||
Resolution (No. of averaging |
0.4 μm |
|||
Sampling rate |
40,000 samplings max./sec. *2 |
|||
Display speed |
20 times/sec. |
|||
Display power |
7-segment 2-color LED |
|||
Over-range alarm |
±FFFF is displayed. |
|||
Control input |
PNP: Applied voltage; 10 to 30 V |
|||
Control output |
Setting method |
Upper/lower 2-level setting x 4 patterns (selectable) |
||
Signal |
PNP open-collector (HIGH, GO and LOW): 100 mA max. (30 V max.) |
|||
Response time |
0.075 ms (at maximum speed) |
|||
OFF-delay time |
60 ms |
|||
Strobe output |
PNP: 100 mA max. (30 V max.), Residual voltage: 1 V max. (N.O.) |
|||
Alarm output |
PNP: 100 mA max. (30 V max.), Residual voltage: 1 V max. (N.C.) |
|||
Analog output voltage |
Output voltage |
±5V |
||
Impedance |
100 Ω |
|||
Response time |
0.075 ms (at maximum speed) |
|||
Temperature characteristics |
0.07% of F.S./°C *3 |
|||
Major functions |
FLL, digital filter, auto zero, offset, calculation, measurement mode (15 types), judgment value memory (4 sets), decimal point shift, display digit changing, display of various errors, etc. |
|||
Rating |
Power voltage |
24 VDC ±10%, Ripple (P-P): 10% max. |
||
Current consumption |
240 mA max. |
|||
Environmental resistance |
Ambient temperature |
0 to 50°C 32 to 122 °F |
||
Relative humidity |
35 to 85%, No condensation |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Weight |
Approx. 235 g |
|||
*1 The above data was obtained using an iron target (S45C, SS400, t=1 mm 0.04"). When measuring aluminum, copper, or stainless steel targets, refer to the linear characteristics for these materials. | ||||





Specifications
Model |
IV4-L6C |
|||
Compatible sensor |
IV4-600CA |
|||
Lights |
Illumination |
White LED |
||
Power supply |
Power supplied via connected sensor |
|||
Environmental resistance |
Enclosure rating |
IP67 *1 |
||
Ambient temperature |
0 to +50°C 32 to +122°F (no freezing) |
|||
Relative humidity |
85% RH or less (no condensation) |
|||
Material |
Main unit case: Aluminum die-casting. Front cover: Acrylic *2 |
|||
Weight |
Approx. 195 g 6.88 oz |
|||
*1 Only when attached to applicable sensor. Except when polarizing filters (OP-88644/OP-88645/OP-88646/OP-88647) are installed. | ||||

Specifications
Model |
OP-89152 |
|||
Type |
Sensor head connector, small (×1) |
|||
Material |
PA66, polycarbonate |
|||
Weight |
Approx. 5 g |
|||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
OP-81283 |
|||
Applicable product |
DL-RS1A |
|||
Length |
5 m 16.40' |
|||
Note |
Connection with external devices that have D-sub 9-pin connectors |
|||

Specifications
Model |
GV-H130L |
|||
Type |
Mid-range |
|||
Light source |
Visible semiconductor laser, Wavelength: 655 nm |
|||
Laser class |
FDA (CDRH) |
Class 1*1 (220 µW) |
||
IEC 60825-1 |
Class 1 (220 µW) |
|||
JIS C6802 | ||||
Detection distance |
55 to 130 mm 2.17" to 5.12" |
|||
Possible display range |
768 to -98 |
|||
Standard detection deviation |
1 mm 0.04" |
|||
Spot diameter |
Approx. ø0.3 mm ø0.012" |
|||
Operation status indicators |
Control output: Red LED/Laser radiation emission indicator: Green LED/1 spot indicator: Green LED |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Operating ambientluminance |
Incandescent lamp |
5000ℓx |
||
Sunlight |
10000ℓx |
|||
Ambient temperature |
-10 to +50 °C 14 to 122 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z axis |
|||
Material |
Housing material: PBT, Display: Polyarylate, Metal: SUS304, Lens cover: Glass, Cable: PVC |
|||
Weight |
Approx. 130 g*3 |
|||
*1 The laser classification for FDA (CDRH) is implemented based on IEC 60825-1 in accordance with the requirements of Laser Notice. | ||||

Specifications
Model |
OP-87587 |
|||
Cable end |
M12 L-shaped type - Loose wires |
|||
Length |
5 m 16.40' |
|||
Material |
Covering: PUR, Nut: Nickel plating over zinc die-cast |
|||

Specifications
Model |
CA-DRW13M |
|||
Type |
Multi-angle Light (Ring) |
|||
LED color |
White |
|||
Power consumption |
19.8 W |
|||
Input voltage |
12 VDC |
|||
Weight |
Approx. 260 g |
|||

Specifications
Model |
OP-84260 |
|||
Type |
Space-saving Fittings |
|||
Applicable product |
SL-VHM |
|||
Number included |
2 pcs. |
|||
Material |
SPHC |
|||
Note |
Holding sensor main body from the side. |
|||


Specifications
Model |
SJ-M021 |
|||
Type |
Static Elimination Head |
|||
Voltage application method |
Pulse AC method |
|||
Applied voltage |
±5.5 kV |
|||
Rated output voltage |
±6 kV |
|||
Ion balance control method |
I.C.C. method |
|||
Static elimination time |
0.5 sec max.*1 |
|||
Ion balance |
±15 V or less*2 |
|||
Supply pressure range |
0.001 to 0.5 MPa*3 |
|||
Min. air pressure |
With SJ-ML |
0.02 MPa (20 Nl/min) |
||
With SJ-MS/ML1 |
0.03 MPa (20 Nl/min) |
|||
With SJ-MS/ML2 |
0.02 MPa (20 Nl/min) |
|||
With SJ-MS/ML3 |
0.08 MPa (50 Nl/min) |
|||
With SJ-MS/ML4 | ||||
Control input |
Static elimination stop input |
Non-voltage input |
||
Control output |
Alarm output |
NPN open collector 100 mA (40 V or less) |
||
Ion level alarm output | ||||
Condition alarm output | ||||
Rating |
Power voltage |
24 VDC ±10 % |
||
Current consumption |
450 mA or less |
|||
Environmental resistance |
Ambient temperature |
0 to +80 °C 32 to 176 °F*4*5 |
||
Relative humidity |
35 to 65 % RH |
|||
Weight |
Approx. 600 g |
|||
*1 At installation distance 50 mm 1.97", air flow 60 Nl/min (ambient temperature 20 to 30 °C 68 to 86 °F, relative humidity 40 to 60 %) | ||||

Specifications
Model |
OP-84252 |
|||
Overview |
Front protective cover protecting detection side of light curtain. |
|||
Applicable product |
SL-V72HM, SL-V36LM |
|||
Number included |
1 pcs. |
|||
Length |
1,444 mm 56.85" |
|||
Material |
Translucent plastic: Polycarbonate Black plastic: ABS |
|||

Specifications
Model |
CA-DC20E |
|||
Type |
Light control expansion unit |
|||
Output |
Light control method |
(1) Constant voltage control method (direct current lighting) (2) Pulse width modulation method (light emitting frequency: 100 kHz) [the controller can be used to switch the setting] |
||
Intensity range |
255-level digital [the controller can be used to switch the setting] |
|||
Connection points |
2 CH (LED connector connections and terminal block connections can be made) |
|||
Voltage |
12 VDC, 24 VDC [DIP switches can be used to switch the setting] |
|||
Capacity |
Max. 40 W (30 W/1 ch maximum) |
|||
Synchronization |
FLASH output synchronization, continuous lighting [the controller can be used to switch the setting] |
|||
Response speed |
(1) Constant voltage control: less than 10 ms during 12 V output, less than 20 ms during 24 V output (2) Pulse width modulation control: less than 1 ms during 12 or 24 V output |
|||
Display |
LED display |
Lighting knob display: green, orange (128 or higher); error display: red (all lit) |
||
Input voltage |
24 VDC ±10% |
|||
Rating |
Current consumption |
3.0 A (12 V output at maximum load)6.5 A (24 V output at maximum load) |
||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F |
||
Relative humidity |
35 to 85 % RH (No condensation)*1 |
|||
Weight |
Approx 590 g |
|||
*1 Environment for illumination unit: Ambient temperature of 0 to +40 °C 32 to 104 °F and relative humidity of 35 to 65 % RH (No condensation). | ||||