PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
LK-H157 |
|||
Mounting mode |
Diffuse reflective / Specular reflective*1 |
|||
Reference distance |
Diffuse reflective: 150 mm 5.91" |
|||
Measuring range |
Diffuse reflective: ±40 mm ±1.57" |
|||
Light source |
Type |
Red semiconductor laser |
||
Wavelength |
655nm |
|||
Laser class |
IEC 60825-1: Class 2 |
|||
Output |
0.95mW |
|||
Spot diameter (at standard distance) |
120 µm x 4,200 µm |
|||
Linearity |
±0.02% of F.S. (F.S.= 80 mm 3.15")*3 |
|||
Repeatability |
0.25 µm*4 |
|||
Sampling cycle |
2.55/5/10/20/50/100/200/500/1000 µs (9 steps selectable) |
|||
Temperature characteristics |
0.01% of F.S. (F.S.= 80 mm 3.15") |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Ambient light |
Incandescent lamp or fluorescent lamp: 5,000 lux max. |
|||
Ambient temperature |
0 to +50 °C 32 to 122 °F*5 |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Material |
Aluminum die-cast |
|||
Weight |
Approx. 300 g |
|||
*1 Use one of the following dark filters when measuring a transparent or mirror surface object: LK-H082/LK-H087: LK-F3, LK-H152/LK-H157: LK-F2 | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
LK-G5001P |
|||
Type |
Separate type Main controller |
|||
Sensor head compatibility |
Compatible |
|||
No. of connectable sensor heads |
2 |
|||
Display |
Minimum display unit |
0.001 µm |
||
Display range |
±999.999 µm to ±9999.99 mm (7 settings selectable) |
|||
Display cycle |
Approx 10 times/sec. |
|||
Display interface |
Display port |
Either the display unit (LK-HD500) or dedicated touch panel (LK-HD1001) can be connected |
||
LED indicator |
LASER ON |
|||
Terminal block |
Analog output voltage |
±10 V output, Output impedance: 100 Ω*1 |
||
Analog current output |
4 to 20 mA, Maximum load resistance: 350 Ω*1 |
|||
No. of analog outputs |
2*1 |
|||
TIMING 1 input |
Voltage input*2 |
|||
RESET 1 input | ||||
Auto-zero 1 input | ||||
Laser remote input |
Non-voltage input*1 |
|||
Alarm output |
PNP open-collector output*1 |
|||
General comparator output | ||||
Expansion connector |
TIMING input |
Voltage input*1 |
||
RESET input | ||||
Auto-zero input | ||||
Program switching input | ||||
Binary selection input | ||||
Alarm output |
PNP open-collector output*1 |
|||
Comparator output | ||||
Binary output | ||||
RS-232C interface |
Baud rate: 9600 to 115200 bps |
|||
USB interface |
USB 2.0 Hi-Speed compliant*3 |
|||
Ethernet interface |
100Base-TX/10Base-T*4 |
|||
EtherNet/IP™interface |
Cyclic communication (implicit messaging) |
|||
PLC-Link |
The following PLCs are supported:Mitsubishi Electric: MELSEC iQ-R Series, iQ-F Series, Q Series, L Series, FX Series |
|||
Head expansion unit connector |
Up to 10 head expansion units can be connected to one main controller |
|||
Expansion unit connector |
Either of the CC-Link unit (LK-CC100) or DeviceNet® unit (LK-DN100) can be connected |
|||
Power supply |
Power supply voltage |
24 VDC ±10% |
||
Maximum current consumption |
0.6 A or less with 1 head/3.5 A or less with 12 heads |
|||
Environmental resistance |
Ambient temperature |
When one or less head expansion unit is connected: 0 to +50 °C 32 to 122 °F. |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Weight |
Approx. 600 g |
|||
*1 NPN open-collector output rating: 50 mA max. (40 V max.), Residual voltage: 0.5 V max. | ||||


PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
LK-G82 |
|||
Reference distance |
Diffused reflection: 80 mm 3.15", Specular reflection: 75.2 mm 2.96"(Specular reflection) |
|||
Measuring range |
Diffused reflection: ±15 mm ±0.59", Specular reflection: ±14 mm ±0.55"*1*2 |
|||
Light source |
Type |
Red semiconductor laser |
||
Wavelength |
655 nm (visible light) |
|||
Laser Class |
Class II (FDA CDRH 21CFR PART1040.10) |
|||
Output |
0.95 mW |
|||
Spot diameter (at reference distance) |
Approx. ø70 µm ø0.0028" |
|||
Linearity |
±0.05 % of F.S. (F.S.= ±15 mm ±0.59")*3 |
|||
Repeatability |
0.2 µm 0.000008"*4 |
|||
Sampling frequency |
20 / 50 / 100 / 200 / 500 / 1,000 µs (Selectable from 6 levels) |
|||
LED display |
Near the center of the measurement: Green lights |
|||
Temperature characteristics |
0.01 % of F.S./°C (F.S.= ±15 mm ±0.59") |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529) |
||
Ambient light |
Incandescent lamp or Fluorescent lamp: 10,000 lux max. |
|||
Ambient temperature |
0 to +50 °C 32 to 122 °F |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Material |
Aluminum die-cast |
|||
Weight |
Approx. 380 g (including the cable) |
|||
*1 The range is obtained by measuring KEYENCE's standard target (ceramic). | ||||

Specifications
Model |
LK-H020 |
|||
Mounting mode |
Diffuse reflective |
|||
Reference distance |
20mm0.787" |
|||
Measuring range |
±3 mm ±0.12"*1 |
|||
Light source |
Type |
Red semiconductor laser |
||
Wavelength |
655nm |
|||
Laser class |
IEC 60825-1: Class 3R |
|||
Output |
4.8mW |
|||
Spot diameter (at standard distance) |
ø25 µm |
|||
Linearity |
±0.02% of F.S. (F.S.= 6 mm 0.24")*2 |
|||
Repeatability |
0.02 µm (0.01 µm)*3 |
|||
Sampling cycle |
2.55/5/10/20/50/100/200/500/1000 µs (9 steps selectable) |
|||
Temperature characteristics |
0.01% of F.S./°C (F.S.= 6 mm 0.24") |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Ambient light |
Incandescent lamp or fluorescent lamp: 10,000 lux max. |
|||
Ambient temperature |
0 to +50 °C 32 to 122 °F*4 |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Material |
Aluminum die-cast |
|||
Weight |
Approx. 230 g |
|||
*1 Measurement range when the sampling cycle is 20 µs or more. | ||||

Specifications
Model |
LJ-S8002 |
|||
Head input |
Up to two LJ-S8000 Series head units |
|||
Number of registered inspection settings |
Up to 1000 settings (depending on SD card capacity and setting contents) for each of SD card 1 and SD card 2; External switching possible |
|||
Master profile / number of reference images |
Up to 400 per setting (depending on SD card capacity) |
|||
Memory card |
• SD card slot × 2 |
|||
Number of tools |
Up to 100 per setting |
|||
Interface |
Control input |
20 points (Input terminal block: 5 points, Parallel I/O: 15 points) |
||
Control output |
• 28 points (Output terminal block: 6 points, Parallel I/O: 22 points) |
|||
RS-232C |
• Numerical value output and control I/O (When in use, PLC Link using the RS-232C port cannot be used) |
|||
PLC link |
• Numerical value output and control I/O using Ethernet or RS-232C ports |
|||
Ethernet |
• Numerical value output and control I/O |
|||
USB |
• In addition to numerical value output, uploading/downloading inspection settings, performing various simulations, and sending/receiving images and other data, and using remote desktop connections are possible via KEYENCE PC application software. |
|||
EtherNet/IPTM |
• Numerical value I/O and control I/O using the Ethernet port or optional EtherNet/IP™ unit CB-NEP20E |
|||
PROFINET |
• Can input/output numerical values and perform control I/O using the Ethernet port or the optional PROFINET unit CB-NPN20EA (Cannot be used with PLC Link, EtherNet/IP™, and EtherCAT®) |
|||
EtherCAT® |
• Numerical value output and control I/O using optional EtherCAT® unit CB-NEC20E (Cannot be used with PLC Link, EtherNet/IP™, or PROFINET) |
|||
Mouse |
Various menus can be controlled using the dedicated mouse (included with the controller) |
|||
SNTP |
Automatic correction of controller date and time when connected to an SNTP server |
|||
USB HDD |
Images and other data can be output by connecting an HDD (2 TB max.) to the dedicated USB port |
|||
Monitor output |
Analog RGB output, XGA 1024 × 768 (24-bit color, 60 Hz) |
|||
Cooling fan |
Available |
|||
Language |
Switchable between English, Japanese, and Chinese (Simplified) |
|||
Ratings |
Power voltage |
24 VDC ±10% |
||
Maximum current consumption |
Max. 2.5 A (Typ. 28 W) |
|||
Environmental resistance |
Ambient temperature |
0 to 45°C 32.0°F to 113.0°F (DIN rail mounting) / 0 to 40°C 32.0°F to 104.0°F (Base surface mounting) |
||
Relative humidity |
85% RH or less (no condensation) |
|||
Weight |
Approx. 2200 g 4.85 lb |
|||
*1 Positive common connection for NPN input devices and negative common connection for PNP input devices supported. | ||||

Specifications
Model |
LK-H085 |
|||
Mounting mode |
Diffuse reflective |
|||
Reference distance |
80 mm 3.15" |
|||
Measuring range |
±18 mm ±0.71"*1 |
|||
Light source |
Type |
Red semiconductor laser |
||
Wavelength |
655nm |
|||
Laser class |
IEC 60825-1: Class 3R |
|||
Output |
4.8mW |
|||
Spot diameter (at standard distance) |
70 µm x 2,500 µm |
|||
Linearity |
±0.02% of F.S. (F.S.= 36 mm 1.42")*2 |
|||
Repeatability |
0.1 µm*3 |
|||
Sampling cycle |
2.55/5/10/20/50/100/200/500/1000 µs (9 steps selectable) |
|||
Temperature characteristics |
0.01% of F.S./°C (F.S.= 36 mm 1.42") |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Ambient light |
Incandescent lamp or fluorescent lamp: 10,000 lux max. |
|||
Ambient temperature |
0 to +50 °C 32 to 122 °F*4 |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Material |
Aluminum die-cast |
|||
Weight |
Approx. 280 g |
|||
*1 Measurement range when the sampling cycle is 20 µs or more. | ||||

Specifications
Model |
LK-G155 |
|||
Reference distance |
150 mm 5.91" (Diffuse reflection),147.5 mm 5.81" (Specular reflection) |
|||
Measuring range |
±40 mm ±1.57" (Diffuse reflection), ±39 mm ±1.54" (Specular reflection) |
|||
Light source |
Type |
Red semiconductor laser |
||
Wavelength |
655nm (Visible light), Class 3R laser product (JIS C6802) |
|||
Laser Class |
Class 3R (IEC 60825-1), Class IIIa (FDA CDRH Part 1040.10) |
|||
Output |
4.8 mW maximum |
|||
Spot diameter (at reference distance) |
Approx. 120 x 1700 µm |
|||
Linearity |
±0.05% of F.S. (F.S.= ±40 mm ±1.57")*1 |
|||
Repeatability |
0.5 µm 0.000020"*2 |
|||
Sampling frequency |
20/50/100/200/500/1,000 µs (Selectable from 6 levels) |
|||
LED display |
Near the center of the measurement: Green lights |
|||
Temperature characteristics |
0.01% of F.S./°C (F.S.= ±40 mm ±1.57") |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529) |
||
Ambient light |
Incandescent lamp or Fluorescent lamp: 10,000 lux max. |
|||
Ambient temperature |
0 to +50 °C 32 to 122 °F |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Material |
Aluminum die-cast |
|||
Weight |
Approx. 290 g (including the cable) |
|||
*1 This value was taken when measuring a KEYENCE standard target (ceramic) in standard mode. | ||||

Specifications
Model |
LK-G402 |
|||
Reference distance |
Diffused reflection: 400 mm 15.75", Specular reflection: 398 mm 15.67" |
|||
Measuring range |
Diffused reflection: ±100 mm ±3.94", Specular reflection: ±99 mm ±3.90"*1*2 |
|||
Light source |
Type |
Red semiconductor laser |
||
Wavelength |
655 nm (visible light) |
|||
Laser Class |
Class II (FDA CDRH 21CFR PART1040.10) |
|||
Output |
0.95 mW |
|||
Spot diameter (at reference distance) |
Approx. ø290 µm ø0.0114" |
|||
Linearity |
±0.05 % of F.S. (F.S.= ±100 mm ±3.94")*3 |
|||
Repeatability |
2 µm 0.000079"*4 |
|||
Sampling frequency |
20 / 50 / 100 / 200 / 500 / 1,000 µs (Selectable from 6 levels) |
|||
LED display |
Near the center of the measurement: Green lights |
|||
Temperature characteristics |
0.01 % of F.S./°C (F.S.= ±100 mm ±3.94") |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529) |
||
Ambient light |
Incandescent lamp or Fluorescent lamp: 5,000 lux max. |
|||
Ambient temperature |
0 to +50 °C 32 to 122 °F |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Material |
Aluminum die-cast |
|||
Weight |
Approx. 380 g (including the cable) |
|||
*1 The range is obtained by measuring KEYENCE's standard target (ceramic). | ||||


Specifications
Model |
LR-XN11N |
|||
Type |
NPN Output |
|||
Cable/Connector |
Cable |
|||
Main Unit/Expansion Unit |
Main Unit |
|||
No. of Control Outputs |
2 |
|||
No. of External Inputs |
1 |
|||
Response Time |
500 µs*1/1 ms/3 ms/10 ms/200 ms Selectable |
|||
IO-Link |
— |
|||
Functions |
Timer Function |
Timer OFF/Off-delay/On-delay/One-shot/On-Off delay/On-delay One-shot |
||
I/O |
Control Output |
Open collector, 30 VDC or lower, N.O./N.C. |
||
External Input |
External Set/Laser OFF/Zero Shift/Hold Reset/Gyro Alert RST selectable |
|||
Unit Expansion |
Up to 8 expansion units possible (including main unit, a total of 9 units connected) However, up to 16-unit expansion is possible when the LR-XN10 is used for expansion with the NU Series. |
|||
Protection Circuit |
Protection against reverse power connection, protection against output overcurrent, protection against output surge, protection against reverse output connection |
|||
Number of Interference Prevention Devices |
OFF/4 units/8 units selectable*2 |
|||
Power supply |
Power voltage |
16 to 30 VDC*3 (including 10% ripple (P-P) or less), class 2 |
||
Power consumption |
During normal operation: 1060 mW (44 mA or lower at 24 V, 61 mA or lower at 16 V), ECO ON/ALL: 895 mW (37 mA or lower at 24 V, 50 mA or lower at 16 V) (excluding Load Current) |
|||
Environmental resistance |
Ambient temperature |
−20 to +55°C -4°F to 131°F (no freezing)*4 |
||
Relative humidity |
35 to 85% RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz; Power Spectral Density: 0.816 G2/Hz; X, Y, and Z directions |
|||
Shock resistance |
500 m/s2 (50G); 3 times each for X, Y, and Z axes |
|||
Case Material |
Main Unit and Cover: Polycarbonate |
|||
Accessories |
Instruction manual |
|||
Weight |
Approx. 80 g |
|||
*1 If 500 µs is selected, the following limitations apply. | ||||

Specifications
Model |
LJ-X8400 |
|||
Reference distance |
380 mm 14.96" |
|||
Measurement range |
Z-axis (height) |
±60 mm ±2.36" (+95 to -220 mm +3.74" to -8.66" *1) (F.S.=315 mm 12.40") |
||
X-axis (width) |
NEAR side |
180 mm 7.09" (163 mm 6.42" *1) |
||
Reference distance |
210 mm 8.27" |
|||
FAR side |
240 mm 9.45" (320 mm 12.60" *1) |
|||
Light source |
Blue semiconductor laser |
|||
Light source |
Wavelength |
405 nm (visible light) |
||
Laser class |
Class 2M laser product (IEC60825-1, FDA (CDRH) Part 1040.10 *2) *3 |
|||
Output |
10 mW |
|||
Spot size |
Approx. 275 mm × 249 μm 10.83" × 0.0098" (reference distance) |
|||
Repeatability |
Z-axis (height) |
5 μm 0.000197" *4*5 |
||
X-axis (width) |
10 μm 0.0004" *4*6 |
|||
Linearity |
Z-axis (height) |
Reference distance: ±60 mm ±2.36" ±0.025% of F.S. (±0.003%) |
||
Profile data interval |
X-axis (width) |
75 μm 0.0030" (50 μm 0.0020"~) |
||
Profile data count |
3200 points |
|||
HDR (high dynamic range) |
Single-shot HDR *9 |
|||
Laser irradiation position confirmation function |
Light source |
Blue LED (405 nm) |
||
Temperature characteristic |
0.01% of F.S./°C |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529) *10 |
||
Ambient light |
Incandescent lamp: 10,000 lux or less *11 |
|||
Ambient temperature |
0 to +45°C 32 to +113°F *12 |
|||
Relative humidity |
85% RH or less (no condensation) |
|||
Vibration resistance |
10 to 57 Hz, double amplitude 1.5 mm 0.06"; 3 hours each for X, Y, and Z axes |
|||
Shock resistance |
15 G / 6 msec |
|||
Material |
Aluminum |
|||
Weight |
Approx. 1300 g 2.87 lb |
|||
*1 When range is extended. | ||||


Specifications
Model |
LR-W500 |
|||
Type |
2 m 6.56' cable type |
|||
Detecting distance |
30 to 500 mm 1.18" to 19.69" |
|||
Min. spot diameter |
Adjustable spot |
|||
Light source |
White LED |
|||
Mutual interference reduction function |
Up to 2 units when alternate frequencies set |
|||
Timer |
OFF/ON delay/OFF delay/One-shot |
|||
Response time |
200 µs/1 ms/10 ms/100 ms/500 ms selectable *1 |
|||
I/O |
Control output |
NPN open collector/PNP open collector selectable |
||
External input |
Tuning /Transmission OFF selectable |
|||
Protection circuit |
Protection against reverse power connection, power supply surge, output overcurrent, output surge, and reverse output connection |
|||
Power supply |
Power voltage |
10 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS |
||
Current consumption |
65 mA or less (without load) at 24 VDC; |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Ambient light |
Incandescent lamp: 10,000 lux or less, Sunlight: 20,000 lux or less |
|||
Ambient temperature |
-20 to +50 °C -4 to 122 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
1,000 m/s2, 6 times in each of the X, Y, and Z directions |
|||
Material |
Case: Zinc die cast (Nickel chrome plating), |
|||
Weight |
Approx. 170 g (including cable) |
|||
*1 When alternate frequencies are set, the response time increases by approximately 20%. | ||||

Specifications
Model |
LK-G87 |
|||
Reference distance |
Diffused reflection: 80 mm 3.15", Specular reflection: 75.2 mm 2.96"(Specular reflection) |
|||
Measuring range |
Diffused reflection: ±15 mm ±0.59", Specular reflection: ±14 mm ±0.55"*1*2 |
|||
Light source |
Type |
Red semiconductor laser |
||
Wavelength |
655 nm (visible light) |
|||
Laser Class |
Class II (FDA CDRH 21CFR PART1040.10) |
|||
Output |
0.95 mW |
|||
Spot diameter (at reference distance) |
Approx. 70 x 1,100 µm |
|||
Linearity |
±0.05 % of F.S. (F.S.= ±15 mm ±0.59")*3 |
|||
Repeatability |
0.2 µm 0.000008"*4 |
|||
Sampling frequency |
20 / 50 / 100 / 200 / 500 / 1,000 µs (Selectable from 6 levels) |
|||
LED display |
Near the center of the measurement: Green lights |
|||
Temperature characteristics |
0.01 % of F.S./°C (F.S.= ±15 mm ±0.59") |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529) |
||
Ambient light |
Incandescent lamp or Fluorescent lamp: 10,000 lux max. |
|||
Ambient temperature |
0 to +50 °C 32 to 122 °F |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Material |
Aluminum die-cast |
|||
Weight |
Approx. 380 g (including the cable) |
|||
*1 The range is obtained by measuring KEYENCE's standard target (ceramic). | ||||

Specifications
Model |
LR-X50 |
|||
Type |
Cable Type |
|||
Detecting Distance |
25.0 to 50.0 mm 0.98" to 1.97" |
|||
Standard Detectable Deviation |
0.5 mm 0.02" |
|||
Display Resolution |
0.1 mm 0.004" |
|||
Spot Size |
Approx. 0.2 mm × 1.5 mm 0.008" × 0.06" |
|||
Response Time |
500 µs*1/1 ms/3 ms/10 ms/200 ms Selectable |
|||
Light Source |
Type |
Green laser (505 nm) |
||
Laser Class |
Class 1 Laser Product (IEC60825-1, FDA (CDRH), Part1040.10*2) |
|||
IO-Link |
Specification v1.1/COM2 (38.4 kbps) |
|||
Functions |
Timer Function |
Timer OFF/Off-delay/On-delay/One-shot/On-Off delay/On-delay One-shot |
||
I/O |
Control Output |
NPN open collector/PNP open collector, N.O./N.C selectable. *3 |
||
External Input |
External Set/Laser OFF/Zero Shift/Hold Reset/Gyro Alert RST selectable *3 |
|||
Protection Circuit |
Protection against reverse power connection, protection against output overcurrent, |
|||
Power supply |
Power voltage |
16 to 30 VDC (including 10% ripple (P-P) or less), class 2 |
||
Power consumption |
During normal operation: 970 mW (38 mA or lower at 24 V, 53 mA or lower at 16 V) (Excluding Load Current) |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Ambient light |
Incandescent lamp: 16000 lux or less |
|||
Ambient temperature |
-10°C to +50°C 14°F to + 122°F (no freezing) |
|||
Relative humidity |
35 to 85% RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz; Power Spectral Density: 0.816 G2/Hz for X, Y and Z axes |
|||
Shock resistance |
1000 m/s2 (100G) 6 times each for X, Y, and Z axes |
|||
Material |
Head Case: SUS316L; Head Lens Cover: PSU |
|||
Accessories |
Instruction manual, laser warning label |
|||
Weight |
Approx. 90 g |
|||
*1 If 500 µs is selected, the following limitations apply. | ||||

Specifications
Model |
LR-X250C |
|||
Type |
M8 Connector Type*1 |
|||
Detecting Distance |
30 to 250 mm 1.18" to 9.84" |
|||
Standard Detectable Deviation |
30 to 180 mm: 9 mm 1.18" to 7.09": 0.35" |
|||
Display Resolution |
1 to 2 mm 0.04" to 0.08" |
|||
Spot Size |
Approx. 0.8 mm × 1.2 mm 0.03" × 0.05" |
|||
Response Time |
500 µs*2/1 ms/3 ms/10 ms/200 ms Selectable |
|||
Light Source |
Type |
Green laser (505 nm) |
||
Laser Class |
Class 1 Laser Product (IEC60825-1, FDA (CDRH), Part1040.10*3) |
|||
IO-Link |
Specification v1.1/COM2 (38.4 kbps) |
|||
Functions |
Timer Function |
Timer OFF/Off-delay/On-delay/One-shot/On-Off delay/On-delay One-shot |
||
I/O |
Control Output |
NPN open collector/PNP open collector, N.O./N.C selectable. *4 |
||
External Input |
External Set/Laser OFF/Zero Shift/Hold Reset/Gyro Alert RST selectable *4 |
|||
Protection Circuit |
Protection against reverse power connection, protection against output overcurrent, |
|||
Power supply |
Power voltage |
16 to 30 VDC (including 10% ripple (P-P) or less), class 2 |
||
Power consumption |
During normal operation: 970 mW (38 mA or lower at 24 V, 53 mA or lower at 16 V) (Excluding Load Current) |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Ambient light |
Incandescent lamp: 8000 lux or less |
|||
Ambient temperature |
-10°C to +50°C 14°F to + 122°F (no freezing) |
|||
Relative humidity |
35 to 85% RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz; Power Spectral Density: 0.816 G2/Hz for X, Y and Z axes |
|||
Shock resistance |
1000 m/s2 (100G) 6 times each for X, Y, and Z axes |
|||
Material |
Head Case: SUS316L; Head Lens Cover: PSU |
|||
Accessories |
Instruction manual, laser warning label |
|||
Weight |
Approx. 35 g |
|||
*1 Ensure the cable length is 30 m 98.4' or less for the M8 connector type. Ensure the cable length is 20 m 65.6' or less when connecting via IO-Link. | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
LJ-X8300 |
|||
Reference distance |
288 mm 11.34" |
|||
Measurement range |
Z-axis (height) |
±53 mm 2.09" (F.S.=106 mm 4.17") |
||
X-axis (width) |
NEAR side |
134 mm 5.28" |
||
Reference distance |
150 mm 5.91" |
|||
FAR side |
160 mm 6.30" |
|||
Light source |
Blue semiconductor laser |
|||
Light source |
Wavelength |
405 nm (visible light) |
||
Laser class |
Class 2M laser product (IEC60825-1, FDA (CDRH) Part 1040.10 *1) *2 |
|||
Output |
10 mW |
|||
Spot size |
Approx. 215 mm × 108 μm 8.46" × 0.0042" (reference distance) |
|||
Repeatability |
Z-axis (height) |
3 μm 0.000118" *3*4 |
||
X-axis (width) |
5 μm 0.000197" *3*5 |
|||
Linearity |
Z-axis (height) |
±0.033% of F.S. (±0.005%) *6 |
||
Profile data interval |
X-axis (width) |
50 μm 0.0020" (40 μm 0.0016"~) *7 |
||
Profile data count |
3200 points |
|||
HDR (high dynamic range) |
Single-shot HDR *8 |
|||
Laser irradiation position confirmation function |
Light source |
Blue LED (405 nm) |
||
Temperature characteristic |
0.01% of F.S./°C |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529) *9 |
||
Ambient light |
Incandescent lamp: 10,000 lux or less *10 |
|||
Ambient temperature |
0 to +45°C 32 to +113°F *11 |
|||
Relative humidity |
85% RH or less (no condensation) |
|||
Vibration resistance |
10 to 57 Hz, double amplitude 1.5 mm 0.06"; 3 hours each for X, Y, and Z axes |
|||
Shock resistance |
15 G / 6 msec |
|||
Material |
Aluminum |
|||
Weight |
Approx. 1400 g 3.09 lb |
|||
*1 Classification performed based on IEC60825-1 in accordance with FDA (CDRH) Laser Notice. | ||||

Specifications
Model |
LK-G152 |
|||
Reference distance |
Diffused reflection: 150 mm 5.91", Specular reflection: 147.5 mm 5.81" (Specular reflection) |
|||
Measuring range |
Diffused reflection: ±40 mm ±1.57", Specular reflection: ±39 mm ±1.54"*1*2 |
|||
Light source |
Type |
Red semiconductor laser |
||
Wavelength |
655 nm (visible light) |
|||
Laser Class |
Class II (FDA CDRH 21CFR PART1040.10) |
|||
Output |
0.95 mW |
|||
Spot diameter (at reference distance) |
Approx. ø120 µm ø0.0047" |
|||
Linearity |
±0.05 % of F.S. (F.S.= ±40 mm ±1.57")*3 |
|||
Repeatability |
0.5 µm 0.000020"*4 |
|||
Sampling frequency |
20 / 50 / 100 / 200 / 500 / 1,000 µs (Selectable from 6 levels) |
|||
LED display |
Near the center of the measurement: Green lights |
|||
Temperature characteristics |
0.01 % of F.S./°C (F.S.= ±40 mm ±1.57") |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529) |
||
Ambient light |
Incandescent lamp or Fluorescent lamp: 5,000 lux max. |
|||
Ambient temperature |
0 to +50 °C 32 to 122 °F |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Material |
Aluminum die-cast |
|||
Weight |
Approx. 290 g (including the cable) |
|||
*1 The range is obtained by measuring KEYENCE's standard target (ceramic). | ||||