Laser Displacement Sensors

229 products

Showing 49 - 72 of 229 products

Showing 49 - 72 of 229 products
View
Keyence Stock Image
Keyence LR-XN10 Keyence
Sale price $276.87
Only 9 units left

Specifications

Model

LR-XN10

Type

Cable/Connector

Main Unit/Expansion Unit

Expansion Unit

No. of Control Outputs

None*1

No. of External Inputs

Response Time

500 µs*2/1 ms/3 ms/10 ms/200 ms Selectable

IO-Link

Functions

Timer Function

Timer OFF/Off-delay/On-delay/One-shot/On-Off delay/On-delay One-shot

I/O

Control Output

External Input

Unit Expansion

Up to 8 expansion units possible (including main unit, a total of 9 units connected) However, up to 16-unit expansion is possible when the LR-XN10 is used for expansion with the NU Series.

Protection Circuit

Protection against reverse power connection, protection against output overcurrent, protection against output surge, protection against reverse output connection

Number of Interference Prevention Devices

OFF/4 units/8 units selectable*3

Power supply

Power voltage

16 to 30 VDC*4 (including 10% ripple (P-P) or less), class 2

Power consumption

During normal operation: 1060 mW (44 mA or lower at 24 V, 61 mA or lower at 16 V), ECO ON/ALL: 895 mW (37 mA or lower at 24 V, 50 mA or lower at 16 V)

Environmental resistance

Ambient temperature

−20 to +55°C -4°F to 131°F (no freezing)*5

Relative humidity

35 to 85% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power Spectral Density: 0.816 G2/Hz; X, Y, and Z directions

Shock resistance

500 m/s2 (50G); 3 times each for X, Y, and Z axes

Case Material

Main Unit and Cover: Polycarbonate

Accessories

Instruction manual

Weight

Approx. 21 g

*1 This counts as 1 output when expanding with multiple units to the FS-MC8N/MC8P and NU Series.
*2 If 500 µs is selected, the following limitations apply.
· Only 2-point calibration can be performed.
· The detection range masking is set during calibration. (Manual setting of the masking range is not supported.)
· Output 2 is limited to an alarm output for errors and gyro issues, and standard/area cannot be used.
· The interference prevention function is not supported
*3 Selecting four or eight interference prevention units causes the response time to change as follows: 4 Units selected: 6 ms/18 ms/60 ms/1.2 s selectable; 8 Units selected: 12 ms/36 ms/120 ms/2.4 s selectable.
*4 When expanding the system with 4 or more expansion units, use a power voltage of 20 V or higher.
*5 Expansion by 1 or 2 units: −20 to +55°C -4°F to 131°F; Expansion by 3 to 10 units: -20 to +50°C -4°F to 122°F, Expansion by 11 to 16 units: -20 to +45°C -4°F to 113°F

Keyence New Stock Image
Keyence LJ-V7080 Keyence
Sale price $740.03
Only 8 units left

Specifications

Model

LJ-V7080

Mounting conditions

Diffuse reflection

Reference distance

80 mm 3.15"

Measurement range

Z-axis (height)

±23 mm 0.91"
(F.S.=46 mm 1.81")

X-axis (width)

NEAR side

25 mm 0.98"

Reference distance

32 mm 1.26"

Far side

39 mm 1.54"

Light source

Type

Blue semiconductor laser

Wavelength

405 nm (visible beam)

Laser class

Class 2 Laser Product
(IEC60825-1, FDA(CDRH) Part 1040.10*1)

Output

4.8 mW

Spot size (reference distance)

Approx. 48 mm × 48 µm
1.89" × 0.001890"

Repeatability

Z-axis (height)

0.5 µm 0.000020"*2*3

X-axis (width)

10 µm 0.000394"*2*4

Linearity

Z-axis (height)

±0.1% of F.S.*5

Profile data interval

X-axis (width)

50 µm 0.002"

Sampling cycle (trigger interval)

Top speed: 16 µs (high-speed mode), Top speed: 32 µs (advanced function mode)*6

Temperature characteristics

0.01% of F.S./°C

Environmental resistance

Enclosure rating

IP67 (IEC60529)*7

Ambient light

Incandescent lamp: 10,000 lux max.*8

Ambient temperature

0 to +45 °C 32 to 113 °F*9

Relative humidity

85% RH or less (no condensation)

Vibration resistance

10 to 57 Hz, Double amplitude 1.5 mm 0.06", 3 hours in each of the X, Y, and Z directions

Shock resistance

15 G/6 ms

Material

Aluminum

Weight

Approx. 400 g

*1 The laser classification for FDA(CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice.
*2 This value is from a case in which measurement has been performed with a reference distance with 4,096 times of averaging.
*3 The measurement targets are KEYENCE standard targets. This value is from a case in which the average height of the default setting area has been measured in height mode. All other settings are default.
*4 The measurement target is a pin gauge. This value is from a case in which the position of the intersection between the rounded surface of the pin gauge and the edge level has been measured in position mode. All other settings are default.
*5 The measurement targets are KEYENCE standard targets. The profile data is from a case in which measurement has been performed with 64 times of smoothing and 8 times of averaging. All other settings are default.
*6 For high-speed mode, when the measurement area is at its minimum, binning is ON, image capture mode is set to standard, and parallel image capture is ON.
All other settings are default. For advanced function mode, when the measurement area is at its minimum, binning is ON and image capture mode is set to standard. All other settings are default.
*7 This value is from a case in which the sensor head cable (CB-B*) or extension cable (CB-B*E) has been connected.
*8 This is the illuminance for the light-receiving surface of the sensor head during white paper measurement when light has been shined onto the white paper.
*9 The sensor head must be mounted on a metal plate for use.

Keyence Stock Image
Keyence LB-1201 Keyence
Sale price $1,775.76
Only 2 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Keyence New Stock Image
Keyence LJ-V7300 Keyence
Sale price $5,085.67
In stock, 11 units

Specifications

Model

LJ-V7300

Mounting conditions

Diffuse reflection

Reference distance

300 mm 11.81"

Measurement range

Z-axis (height)

±145 mm 5.71"
(F.S.=290 mm 11.42")

X-axis (width)

NEAR side

110 mm 4.33"

Reference distance

180 mm 7.09"

Far side

240 mm 9.45"

Light source

Type

Blue semiconductor laser

Wavelength

405 nm (visible beam)

Laser class

Class 2 Laser Product
(IEC60825-1, FDA(CDRH) Part 1040.10*1)

Output

4.8 mW

Spot size (reference distance)

Approx. 240 mm × 610 µm
9.45" × 0.024016"

Repeatability

Z-axis (height)

5 µm 0.000197"*2*3

X-axis (width)

60 µm 0.002363"*2*4

Linearity

Z-axis (height)

±0.05 to ±0.15% of F.S.*5*6

Profile data interval

X-axis (width)

300 µm 0.012"

Sampling cycle (trigger interval)

Top speed: 16 µs (high-speed mode), Top speed: 32 µs (advanced function mode)*7

Temperature characteristics

0.01% of F.S./°C

Environmental resistance

Enclosure rating

IP67 (IEC60529)*8

Ambient light

Incandescent lamp: 10,000 lux max.*9

Ambient temperature

0 to +45 °C 32 to 113 °F*10

Relative humidity

85% RH or less (no condensation)

Vibration resistance

10 to 57 Hz, Double amplitude 1.5 mm 0.06", 3 hours in each of the X, Y, and Z directions

Shock resistance

15 G/6 ms

Material

Aluminum

Weight

Approx. 1,000 g

*1 The laser classification for FDA(CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice.
*2 This value is from a case in which measurement has been performed with a reference distance with 4,096 times of averaging.
*3 The measurement targets are KEYENCE standard targets. This value is from a case in which the average height of the default setting area has been measured in height mode. All other settings are default.
*4 The measurement target is a pin gauge. This value is from a case in which the position of the intersection between the rounded surface of the pin gauge and the edge level has been measured in position mode. All other settings are default.
*5 The measurement targets are KEYENCE standard targets. The profile data is from a case in which measurement has been performed with 64 times of smoothing and 8 times of averaging. All other settings are default.
*6 The linearity will differ depending on the measurement area.
*7 For high-speed mode, when the measurement area is at its minimum, binning is ON, image capture mode is set to standard, and parallel image capture is ON.
All other settings are default. For advanced function mode, when the measurement area is at its minimum, binning is ON and image capture mode is set to standard. All other settings are default.
*8 This value is from a case in which the sensor head cable (CB-B*) or extension cable (CB-B*E) has been connected.
*9 This is the illuminance for the light-receiving surface of the sensor head during white paper measurement when light has been shined onto the white paper.
*10 The sensor head must be mounted on a metal plate for use.

Keyence Stock Image
Keyence LK-2111 Keyence
Sale price $4,792.49
Only 4 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

LK-G3001P Keyence
Keyence LK-G3001P Keyence
Sale price $1,364.32
In stock, 54 units

Specifications

Model

LK-G3001P*1

Type

Separate monitor model*2

Display

Head compatibility

All LK-G sensor heads are compatible

Number of connectable sensors

Maximum of 2 units

Minimum display unit

0.01 µm

Display range

±9,999.99 mm to ±9,999.99 µm (Selectable from six levels)

Refresh rate

10 times/sec

Terminal block

Analog voltage output

±10 V x 2 outputs, output impedance: 100 Ω

Analog current output

4 to 20 mA x 2 outputs, maximum load resistance: 350 Ω

Timing input

For OUT1, voltage input

Reset input

Auto-zero input

Laser remote interlock input

Non-voltage input

Comparator output

For OUT1, PNP open-collector output

Alarm output

For OUT1, PNP open-collector output (N.C.)

Expansion connector

Timing input

For OUT2, voltage input

Reset input

Auto-zero input

Program switching input

Voltage input x 3 inputs

Laser-Off input

For Head A/Head B, voltage input

Comparator output

For OUT2, PNP open-collector output

Alarm output

For OUT2, PNP open-collector output (N.C.)

Binary

Binary output

Measured data output (21 bits), OUT1/OUT2 selectable, PNP open-collector output

Strobe output

PNP open-collector output

Binary selector output

Binary selector input

Voltage input

RS-232C interface

Measured data output and control input/output (Maximum baud rate: 115,200 bps, selectable)

USB interface

In conformity with USB Revision 2.0 Full speed (USB1.1 compatible)

Major functions

2 OUT simultaneous measurement, Operation, Averaging, Filter, Calibration, Measurement, AUTO ZERO,
Sampling frequency setting, Mutual interference prevention, Data storage, 8-program memory, ECO mode,
ABLE setting, Target setting, ABLE tuning, Selection of measurement surface of transparent target,
Statistics processing, Connection of setting support software, Selectable head-mounting, etc.

Rating

Power voltage

24 VDC ±10 %, Ripple (P-P) 10 % or less

Current consumption

500 mA or less with 1 head/600 mA or less with 2 heads

Environmental resistance

Ambient temperature

0 to +50 °C 32 to 122 °F

Relative humidity

35 to 85 % RH (No condensation)

Weight

Approx. 370 g

*1 The rating of the PNP open collector: 50 mA max. (30 V max.), residual voltage of 1 V max.
The rating of voltage input: 10.2 V or more ON voltage (26.4 V max.) 0.6 mA or less OFF current.
*2 LK-G3001P can be operated singly. The measured value display and setting modifications can be performed on the display panel (LK-GD500) or via the setting support software (LK-H1W).

Keyence Stock Image
Keyence LK-G3000V Keyence
Sale price $1,613.59
Only 5 units left
Buy the Keyence LK-G3000V - a genuine Keyence industrial automation component engineered for reliable performance in demanding manufacturing and process control environments. The Keyence LK-G3000V is a direct drop-in replacement for existing installations and ships ready for integration.
Keyence New Stock Image
Keyence LJ-G080 Keyence
Sale price $967.65
In stock, 15 units

Specifications

Model

LJ-G080

Mounting

Diffuse reflective

Reference distance

80 mm 3.15"

Measuring range

Z-axis (Height)

±23 mm ±0.91"

X-axis (Width)

Near

25 mm 0.98"

Reference distance

32 mm 1.26"

Far

39 mm 1.54"

Light source

Type

Red semiconductor laser

Wavelength

655nm (Visible light), Class 2 laser product (JIS C6802)

Output

0.95 mW

Laser Class

Class II Laser Product (FDA (CDRH) 21CFR PART1040.10), Class 2 Laser Product (IEC 60825-1)

Spot shape (at reference distance)

Approx 80 µm x 46 mm
0.003150" x 1.81"

Repeatability

Z-axis (Height)

1 µm 0.000040"*1

X-axis (Width)

10 µm 0.000394"*2

Linearity Z-axis (Height)

±0.1% of F.S.*3

Sampling cycle (trigger interval)

3.8 ms*4

Temperature characteristics

0.02% of F.S./°C

Environmental resistance

Enclosure rating

IP67 (IEC60529)

Ambient light

Incandescent lamp or fluorescent lamp: 5,000 lux max.*5

Ambient temperature

0 to +50 °C 32 to 122 °F

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Aluminum

Weight

Approx. 350 g

*1 The value obtained after 64 times averaging at the reference distance.The target is KEYENCE standard object. The value is the average of the widths in the Height mode.
*2 The value obtained after 64 times averaging at the reference distance.The target is ø10 mm ø0.39" pin gauge. The value is the edge in the Position mode after 16 times of the Smoothing.
*3 The target is KEYENCE standard object. The value is the average of the widths in the Height mode.
*4 With initial setting, minimum measuring range, and single smoothing processing
*5 The illumination on the receiver of the sensor head when targeting an illuminated white paper.

Keyence New Stock Image
Keyence LR-ZB250AN Keyence
Sale price $257.51
Only 8 units left

Specifications

Model

LR-ZB250AN

Type

Distance based laser sensor

Appearance

Rectangular

Output

NPN

Cable connection

2 m cable

Detectable distance

35 to 250 mm 1.38" to 9.84" (215 to 0)*1

Standard detectable deviation

35 to 180 mm 1.38" to 7.09": 9 mm 0.35"
180 to 250 mm 7.09" to 9.84": 25 mm 0.98"

Display resolution

1 to 3 (1 to 3 mm 0.04" to 0.12")

Spot size

Approx. 2.4 × 1.2 mm 0.09" × 0.05" at 250 mm 9.84"

Response time

1.5 ms / 10 ms / 50 ms selectable

Light source

Type

Red laser (660 nm)

Laser class

Class 1 laser product
(IEC60825-1, FDA (CDRH) Part1040.10*2)

Function

Indicator

3-digit 7-segment display (red),
output indicator (yellow),
DATUM indicator (orange),
1 spot indicator (green)

Timer

OFF/ON delay/OFF delay/One-shot

Specifications

Power voltage

10 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS

Power consumption

450 mW or less (18 mA or less at 24 V, 34 mA or less at 12 V)

Control output

NPN Open collector,
Applied voltage 30 VDC or less, Control current 100 mA or less,
Residual voltage 1.2 V or less at 10 mA or less, 2 V or less at 10 to 100 mA

Protection circuit

Protection against reverse power connection, output overcurrent, output surge, reverse output connection

Output operation

Light-ON / Dark-ON selectable

External input

Input time calibration: 35 ms or more ON, 35 ms or more OFF
Laser emission stop: 2 ms or more ON, 20 ms or more OFF
Short-circuit current NPN: 1 mA or less/PNP: 2 mA or less

Environmental resistance

Enclosure rating

IP68 (IEC60529), IP69K (DIN40050-9), NEMA 4X, 6P, 13 (NEMA250), ECOLAB*3, Diversey*3

Insulation resistance

20 MΩ or more (500 VDC)

Ambient light

Incandescent lamp: 2,000 lux or less
Sunlight: 4,000 lux or less*4

Ambient temperature

-10 to +50 °C 14 to 122 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Storage temperature

-25 to +75 °C -13 to 167 °F (No freezing)

Withstand voltage

1,000 VAC, 50/60 Hz, 1 min

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

1,000 m/s2, 6 times in each of the X, Y, and Z directions

Material

Case: SUS316L, Display: PES, Lens cover: PMMA with scratch-resistant coating,
Packing/Connector ring: FKM

Accompanying items

Instruction Manual,
Certification/Identification label (FDA)

Weight

Approx. 110 g (Including cable)

*1 Display readings can be used as a guide for the detecting distance. When the setting value is tuned, the readout shifts. When the value exceeds "-99", "-FF" is displayed.
*2 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice.
*3 Have passed resistance tests with cleaning agents from multiple manufactures.
*4 When the response time is 10 ms

Keyence New Stock Image
Keyence LR-ZH500CN Keyence
Sale price $402.26
Only 10 units left

Specifications

Model

LR-ZH500CN

Type

U.C.D. Function
Distance based laser sensor

Appearance

Rectangular

Output

NPN

Cable connection

M8 connector, 4-pin

Detectable distance

35 to 500 mm 1.38" to 19.69"(465 to 0)*1

Standard detectable deviation

35 to 180 mm 1.38" to 7.09": 9 mm 0.35"
180 to 300 mm 7.09" to 11.81": 25 mm 0.98"
300 to 400 mm 11.81" to 15.75": 40 mm 1.57"
400 to 500 mm 15.75" to 19.69": 50 mm 1.97"

Display resolution

1 to 5 (1 to 5 mm 0.04" to 0.20")

Spot size

Approx. ø3 mm ø0.12"

Response time

1.5 ms / 10 ms / 50 ms selectable

Light source

Type

Red laser (660 nm)

Laser class

Class 2 laser product (IEC60825-1)
Class II Laser product (FDA(CDRH) Part1040.10)

Function

Indicator

3-digit 7-segment display (white),
output indicator (yellow),
DATUM indicator (orange),
1 spot indicator (green)

Timer

OFF/ON delay/OFF delay/One-shot

Specifications

Power voltage

10 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS

Power consumption

450 mW or less (18 mA or less at 24 V, 34 mA or less at 12 V)

Control output

NPN Open collector,
Applied voltage 30 VDC or less, Control current 100 mA or less,
Residual voltage 1.2 V or less at 10 mA or less, 2 V or less at 10 to 100 mA

Protection circuit

Protection against reverse power connection, output overcurrent, output surge, reverse output connection

Output operation

Light-ON / Dark-ON selectable

External input

Input time calibration: 35 ms or more ON, 35 ms or more OFF
Laser emission stop: 2 ms or more ON, 20 ms or more OFF
Short-circuit current NPN: 1 mA or less/PNP: 2 mA or less

Environmental resistance

Enclosure rating

IP68 (IEC60529), IP69K (DIN40050-9), NEMA 4X, 6P, 13 (NEMA250), ECOLAB*2, Diversey*2

Insulation resistance

20 MΩ or more (500 VDC)

Ambient light

Incandescent lamp: 10,000 lux or less
Sunlight: 20,000 lux or less at 250 mm 9.84"*3
Incandescent lamp: 2,000 lux or less
Sunlight: 4,000 lux or less at 500 mm 19.69"*3

Ambient temperature

-10 to +50 °C 14 to 122 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Storage temperature

-25 to +75 °C -13 to 167 °F (No freezing)

Withstand voltage

1,000 VAC, 50/60 Hz, 1 min

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

1,000 m/s2, 6 times in each of the X, Y, and Z directions

Material

Case: SUS316L, Display: PES, Lens cover: PMMA with scratch-resistant coating,
Packing/Connector ring: FKM

Accompanying items

Instruction Manual,
FDA warning/certification/identification label,
Laser warning/explanation labels

Weight

Approx. 55 g

*1 Display readings can be used as a guide for the detecting distance. When the setting value is tuned, the readout shifts. When the value exceeds "-99", "-FF" is displayed.
*2 Have passed resistance tests with cleaning agents from multiple manufactures.
*3 When the response time is 10 ms

Keyence Stock Image
Keyence LB-1101W Keyence
Sale price $704.40
Only 1 unit left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

LK-H027K Keyence
Keyence LK-H027K Keyence
Sale price $2,507.38
Only 8 units left

Specifications

Model

LK-H027K

Mounting mode

Specular reflective

Reference distance

16.1mm0.634"

Measuring range

±2.8 mm ±0.11"*1

Light source

Type

Red semiconductor laser

Wavelength

655nm

Laser class

IEC 60825-1: Class 2
FDA(CDRH)21CFR Part 1040.10: Class II

Output

0.95mW

Spot diameter (at standard distance)

25 µm x 1,400 µm

Linearity

±0.02% of F.S. (F.S.= 6 mm 0.24")*2

Repeatability

0.02 µm (0.01 µm)*3

Sampling cycle

2.55/5/10/20/50/100/200/500/1000 µs (9 steps selectable)

Temperature characteristics

0.01% of F.S./°C (F.S.= 6 mm 0.24")

Environmental resistance

Enclosure rating

IP67

Ambient light

Incandescent lamp or fluorescent lamp: 10,000 lux max.

Ambient temperature

0 to +50 °C 32 to 122 °F

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Aluminum die-cast

Weight

Approx. 230 g

*1 Measurement range when the sampling cycle is 20 µs or more.
*2 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008/LK-H008W) is measured in the normal measurement mode.
*3 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008/LK-H008W) is measured at the reference distance with the number of averaging measurements set to 16384. The value in parentheses is a typical e x ample of a measurement with the number of averaging measurements set to 65536 and the sampling cycle to 200 µs.

keyence Stock Image
Keyence LJ-X8000E Keyence
Sale price $9,070.49
Only 4 units left

Specifications

Model

LJ-X8000E*1

Head input

Up to 2 head units
Compatible with LJ-X8000 Series heads and LJ-V7000 Series heads
*When using 2 units, heads A and B are the same model.

Sampling cycle (trigger interval)

[2D mode] Maximum speed of 1 kHz (1 ms) *2
[3D mode] -

Number of registered inspection settings

Up to 1000 (depending on SD card capacity and setting contents) for each of SD cards 1 and 2. External switching is possible

Master profile / number of reference images

Maximum 200 per setting per head (depends on SD card capacity)

Memory card

• SD card slot × 2
• Supports OP-87133 (512 MB), CA-SD1G (1 GB), CA-SD4G (4 GB), CA-SD16G (16 GB)
*In the SD1 slot, CA-SD4G is equipped as standard for 8000, and CA-SD1G is equipped as standard for 8000E

Number of tools

100/setting (of those, 20 are for misalignment correction)

Interface

Control input

20 points (input terminal block: 5 points, parallel I/O: 15 points)

Control output

28 points (output terminal block: 6 points, parallel I/O: 22 points)
Photo MOSFET*3

RS-232C

• Value output and control I/O (exclusive use with PLC link using an RS-232C port)
• Supports baud rates up to 230,400 bps

PLC link

• Value output using Ethernet port or RS-232C port, and control I/O
(Exclusive use with EtherNet/IP™ and PROFINET. When using an RS-232C port, exclusive use with RS-232C no-procedure communication)

Ethernet

• Value output and control I/O
• In addition to the above functions, can upload/download inspection settings, perform various simulations, send/receive various data including profile and image data, and be used with remote connection programs via KEYENCE PC application software
• Supports FTP client and FTP server functions
• Supports VNC server functions (for non-PC clients, only displaying the monitor screen is supported)
• Supports BOOTP functions
• 1000BASE-T/100BASE-TX/10BASE-T
• Supports jumbo frames (when connected to any of CB-NEC20E/NEP20E/NPN20E)

USB

• Can output values (3D mode only), upload/download inspection settings, perform various simulations, send/receive various data including profile and image data, and be used with remote connection programs via KEYENCE PC application software
• Dedicated USB 2.0

EtherNet/IP™

• Can input/output numerical values and perform control I/O using the Ethernet port or the optional EtherNet/IP™ unit CB-NEP20E (Cannot be used with PLC Link, PROFINET, and EtherCAT®)
• Supports cyclic communication (max. 1436 bytes) and message communication
• Maximum number of connections: 32 (Ethernet port)/1: Exclusive Owner, 4: Input Only (CB-NEP20E)
• Complies with Version.CT15 (Ethernet port)/CT17 (CB-NEP20E) conformance test

PROFINET

• Can input/output numerical values and perform control I/O using the Ethernet port or the optional PROFINET unit CB-NPN20EA (Cannot be used with PLC Link, EtherNet/IP, and EtherCAT®)
• Supports cyclic communication (max. 1408 bytes) (Ethernet port) / 1252 bytes (CB-NPN20EA)
• Supports acyclic communication (recorded data)
• Complies with Conformance Class A (Ethernet port) / C (CB-NPN20EA)

EtherCAT®

• Can output numerical values and perform control I/O by connecting the optional EtherCAT® unit CB-NEC20E (Cannot be used with PLC link, EtherNet/IP™, and PROFINET)
• Supports cyclic communication (process data object communication) (Input: Max. 536 bytes/Output: Max. 532 bytes)
• Supports acyclic communication (mailbox communication)
• Supports CoE
• Explicit Device Identification
• Complies with V2.2.10 and V2.2.1.0 conformance test

Mouse

Various menus can be controlled via the dedicated mouse (included with the controller)

SNTP

Automatic correction of date and time for this unit is possible by connecting to an SNTP server

USB HDD

By connecting an HDD (max. 2 TB) to the dedicated USB port (supports USB 3.0,
bus-powered, rated output: 900 mA), profile, image and other data can be output

Monitor output

Analog RGB output, XGA 1024 × 768 (24-bit color, 60 Hz)

Encoder input

1 port: combination RS-422 line-driver output (with 5 V output: maximum 150 mA) open collector output (compatible with 5 V, 12 V, 24 V)

Response frequency

RS-422

Single phase / Z phase: 1.6 MHz, 2 phase / 1x: 1.6 MHz, 2 phase / 2x: 3.2 MHz, 2 phase / 4x: 6.4 MHz

Open collector (OC)

Single phase / Z phase: 100 kHz, 2 phase / 1x: 100 kHz, 2 phase / 2x: 200 kHz, 2 phase / 4x: 400 kHz

Laser ON input

Non-voltage input (Shorted with short pin when shipped from factory)

Cooling fan

Provided

Minimum display unit

0.1 µm 0.000004", 0.01°, 0.00001 mm2

Language

Switchable between English, Japanese, Simplified Chinese, Traditional Chinese, Korean, German, French, Italian, Thai, Czech, Hungarian, and Polish

Ratings

Power voltage

24 V DC ±10%

Maximum current consumption

3.3 A

Environmental resistance

Ambient temperature

0 to +45°C 32 to +113°F (DIN rail mounting) / 0 to +40°C 32 to +104°F (base surface mounting)

Relative humidity

85% RH or less (no condensation)

Weight

Approx. 2500 g

*1 3D mode cannot be used with the LJ-X8000E.
*2 When the measurement range is narrowed in accordance with the binning settings.
*3 Positive common connection is supported for NPN input devices, and negative common connection for PNP input devices.

Keyence New Stock Image
Keyence LR-XH50 Keyence
Sale price $498.77
In stock, 11 units

Specifications

Model

LR-XH50

Type

Cable Length: 2 m 6.6'

Detecting Distance

25.0 to 50.0 mm 0.98" to 1.97"

Standard Detectable Deviation

0.5 mm 0.02"

Display Resolution

0.1 mm 0.004"

Spot Size

Approx. 0.2 mm × 1.5 mm 0.008" × 0.06"
(at a detecting distance of 50 mm 1.97")

Light Source

Type

Green laser (505 nm)

Laser Class

Class 1 laser product (IEC60825-1, FDA (CDRH), Part1040.10*1)

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Ambient light

Incandescent lamp: 16,000 lux or less, Sunlight: 16000 lux or less

Ambient temperature

-10°C to +50°C 14°F to 122°F (no freezing)

Relative humidity

35 to 85% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power Spectral Density: 0.816 G2/Hz for X, Y and Z axes

Shock resistance

1000 m/s2 (100G); 6 times each for X, Y, and Z axes

Material

Case: SUS316L; Lens Cover: PSU; Gasket: FKM (lens cover), EVM (cable)

Accessories

Laser warning label

Weight

approx. 75 g

*1 Classification performed based on IEC60825-1 standards in accordance with FDA (CDRH) Laser Notice.

Keyence New Stock Image
Keyence LK-GC10 Keyence
Sale price $654.42
Only 8 units left

Specifications

Model

LK-GC10

Cable length

10 m 32.8'

Weight

Approx. 750 g (including the cable)

Keyence New Stock Image
Keyence LK-031 Keyence
Sale price $2,315.07
Only 9 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence New Stock Image
Keyence LR-X250 Keyence
Sale price $450.51
In stock, 12 units

Specifications

Model

LR-X250

Type

Cable Type

Detecting Distance

30 to 250 mm 1.18" to 9.84"

Standard Detectable Deviation

30 to 180 mm: 9 mm 1.18" to 7.09": 0.35"
180 to 250 mm: 18 mm 7.09" to 9.84": 0.71"

Display Resolution

1 to 2 mm 0.04" to 0.08"

Spot Size

Approx. 0.8 mm × 1.2 mm 0.03" × 0.05"
(at a detecting distance of 250 mm 9.84")

Response Time

500 µs*1/1 ms/3 ms/10 ms/200 ms Selectable

Light Source

Type

Green laser (505 nm)

Laser Class

Class 1 Laser Product (IEC60825-1, FDA (CDRH), Part1040.10*2)

IO-Link

Specification v1.1/COM2 (38.4 kbps)

Functions

Timer Function

Timer OFF/Off-delay/On-delay/One-shot/On-Off delay/On-delay One-shot

I/O

Control Output

NPN open collector/PNP open collector, N.O./N.C selectable.  *3
30 VDC or lower, 50 mA or lower, Residual voltage 2 V or lower

External Input

External Set/Laser OFF/Zero Shift/Hold Reset/Gyro Alert RST selectable  *3
Short circuit current - NPN: 1 mA or lower, PNP: 2 mA or lower
Input time 3 ms or more ON, 20 ms or more OFF
(25 ms or more ON, 25 ms or more OFF when External Set is selected only)

Protection Circuit

Protection against reverse power connection, protection against output overcurrent,
protection against output surge, protection against reverse output connection

Power supply

Power voltage

16 to 30 VDC (including 10% ripple (P-P) or less), class 2

Power consumption

During normal operation: 970 mW (38 mA or lower at 24 V, 53 mA or lower at 16 V) (Excluding Load Current)
ECO ON/ALL: 821 mW (32 mA or lower at 24 V, 44 mA or lower at 16 V) (Excluding Load Current)

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Ambient light

Incandescent lamp: 8000 lux or less
Sunlight: 8000 lux or less

Ambient temperature

-10°C to +50°C 14°F to + 122°F (no freezing)

Relative humidity

35 to 85% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power Spectral Density: 0.816 G2/Hz for X, Y and Z axes

Shock resistance

1000 m/s2 (100G) 6 times each for X, Y, and Z axes

Material

Head Case: SUS316L; Head Lens Cover: PSU
Head Gasket: FKM (lens cover), EVM (cable)
Cable: PVC
Amplifier Case: PBT; Amplifier Display, Indicator: PAR; Amplifier Gasket: NBR; Button: POM

Accessories

Instruction manual, laser warning label

Weight

Approx. 90 g

*1 If 500 µs is selected, the following limitations apply.
· Only 2-point calibration can be performed.
· The detection range masking is set during calibration. (Manual setting of the masking range is not supported.)
· Output 2 is limited to an alarm output for errors and gyro issues, and standard/area cannot be used.
*2 Classification performed based on IEC60825-1 standards in accordance with FDA (CDRH) Laser Notice.
*3 The I/O can be selected from the following combinations. Control output × 2, Control output + External input

Keyence Stock Image
Keyence LK-2100 Keyence
Sale price $3,938.92
Only 5 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Keyence New Stock Image
Keyence LR-X100C Keyence
Sale price $522.89
In stock, 11 units

Specifications

Model

LR-X100C

Type

M8 Connector Type*1

Detecting Distance

25.0 to 100.0 mm 0.98" to 3.94"

Standard Detectable Deviation

1.0 mm 0.04"

Display Resolution

0.1 mm 0.004"

Spot Size

Approx. 0.3 mm × 2 mm 0.012" × 0.08"
(at a detecting distance of 100 mm 3.94")

Response Time

500 µs*2/1 ms/3 ms/10 ms/200 ms Selectable

Light Source

Type

Green laser (505 nm)

Laser Class

Class 1 Laser Product (IEC60825-1, FDA (CDRH), Part1040.10*3)

IO-Link

Specification v1.1/COM2 (38.4 kbps)

Functions

Timer Function

Timer OFF/Off-delay/On-delay/One-shot/On-Off delay/On-delay One-shot

I/O

Control Output

NPN open collector/PNP open collector, N.O./N.C selectable.  *4
30 VDC or lower, 50 mA or lower, Residual voltage 2 V or lower

External Input

External Set/Laser OFF/Zero Shift/Hold Reset/Gyro Alert RST selectable  *4
Short circuit current - NPN: 1 mA or lower, PNP: 2 mA or lower
Input time 3 ms or more ON, 20 ms or more OFF
(25 ms or more ON, 25 ms or more OFF when External Set is selected only)

Protection Circuit

Protection against reverse power connection, protection against output overcurrent,
protection against output surge, protection against reverse output connection

Power supply

Power voltage

16 to 30 VDC (including 10% ripple (P-P) or less), class 2

Power consumption

During normal operation: 970 mW (38 mA or lower at 24 V, 53 mA or lower at 16 V) (Excluding Load Current)
ECO ON/ALL: 821 mW (32 mA or lower at 24 V, 44 mA or lower at 16 V) (Excluding Load Current)

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Ambient light

Incandescent lamp: 16000 lux or less
Sunlight: 16000 lux or less

Ambient temperature

-10°C to +50°C 14°F to + 122°F (no freezing)

Relative humidity

35 to 85% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power Spectral Density: 0.816 G2/Hz for X, Y and Z axes

Shock resistance

1000 m/s2 (100G) 6 times each for X, Y, and Z axes

Material

Head Case: SUS316L; Head Lens Cover: PSU
Head Gasket: FKM (lens cover), EVM (cable)
Cable: PVC
Amplifier Case: PBT; Amplifier Display, Indicator: PAR; Amplifier Gasket: NBR; Button: POM
Amplifier M8 Connector: SUS303

Accessories

Instruction manual, laser warning label

Weight

Approx. 35 g

*1 Ensure the cable length is 30 m 98.4' or less for the M8 connector type. Ensure the cable length is 20 m 65.6' or less when connecting via IO-Link.
*2 If 500 µs is selected, the following limitations apply.
· Only 2-point calibration can be performed.
· The detection range masking is set during calibration. (Manual setting of the masking range is not supported.)
· Output 2 is limited to an alarm output for errors and gyro issues, and standard/area cannot be used.
*3 Classification performed based on IEC60825-1 standards in accordance with FDA (CDRH) Laser Notice.
*4 The I/O can be selected from the following combinations. Control output × 2, Control output + External input

LK-G10 Keyence
Keyence LK-G10 Keyence
Sale price $1,017.21
In stock, 47 units

Specifications

Model

LK-G10

Reference distance

10 mm 0.39"

Measuring range

±1 mm ±0.04"*1*2

Light source

Type

Red semiconductor laser

Wavelength

655 nm (visible light)

Laser Class

Class II (FDA CDRH 21CFR PART1040.10)

Output

0.3 mW

Spot diameter (at reference distance)

Approx. ø20 µm ø0.0008"

Linearity

±0.03 % of F.S. (F.S.= ±1 mm ±0.04")*3

Repeatability

0.02 µm (0.01 µm)*4

Sampling frequency

20 / 50 / 100 / 200 / 500 / 1,000 µs (Selectable from 6 levels)

LED display

Near the center of the measurement: Green lights
Within the measurement area: Orange lights
Outside the measurement area: Orange flashing

Temperature characteristics

0.01 % of F.S./°C (F.S.= ±1 mm ±0.04")

Environmental resistance

Enclosure rating

IP67 (IEC60529)

Ambient light

Incandescent lamp or Fluorescent lamp: 10,000 lux max.

Ambient temperature

0 to +50 °C 32 to 122 °F

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Aluminum die-cast

Weight

Approx. 190 g (including the cable)

*1 The range is obtained by measuring KEYENCE's standard target (ceramic).
*2 When the sampling rate is 20 µs, the range becomes +0.37 mm +0.01" (FAR side) to -1 mm -0.04" (NEAR side).
*3 The range is obtained by measuring KEYENCE's standard target (ceramic) with the Standard mode.
*4 The range is obtained by measuring KEYENCE's standard (SUS) with 4,096 times of averaging at the reference distance. The range in parenthesis is the typical linearity obtained by measuring the target with 16, 384.

keyence Stock Image
Keyence LJ-S320 Keyence
Sale price$0.00
Sold Out

Specifications

Model

LJ-S320

Reference distance

470.5 mm 18.52"*1

Measurement range

Z-axis (height)

+100/−120 mm +3.94"/−4.72" (F.S.=220 mm 8.66")

X-axis (width)

NEAR side

243 mm 9.57"

Reference distance

295 mm 11.61"

FAR side

320 mm 12.60"

Y-axis

Reference distance

XY data interval

100 μm 0.0039"

Number of XY data points

3200×3200

Light source

Laser light source

405 nm (visible light) wavelength blue semiconductor laser

Laser class

Class 2M laser product*2 (IEC 60825-1, FDA (CDRH) Part 1040.10*3)

Output

10 mW

Repeatability

Z-axis (height)

5 μm 0.000197"*4

XY (distance)

10 μm 0.0004"*5

Linearity

Standard area

±0.027% of F.S.*6

High-accuracy area

Imaging time

Min. 0.3 sec *7

I/F

Ethernet

1000BASE-T, 100BASE-TX

Input

LASER_ON, TRG, MEM_CLEAR *8

Output

READY, EXPOSURE_BUSY, ERROR *8

Ratings

Power voltage

24 VDC +25%, -20%

Current consumption / Power

Max. 5.5 A (at 19.2 V), 4.4 A (at 24 V)*9 / Typ. 17 W

Environmental resistance

Enclosure rating

IP65 (IEC60529) *10

Ambient light

Incandescent lamp: 10000 lux or less *11

Ambient temperature

0 to +45°C 32.0°F to +113.0°F *12

Relative humidity

85% RH or below (no condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.033 G2/Hz; X, Y, and Z directions (IEC 60068-2-64)

Shock resistance

15 G (IEC 60068-2-27)

Material

Aluminum

Weight

Approx. 3700 g 8.16 lb

*1 The reference distance is the distance from the bottom edge of the head to the measurement center of the Z-axis (height). See the Dimensions section for the installation reference plane.
*2 Do not view the beam directly using optical instruments (such as eye loupes, magnifiers, microscopes, telescopes, or binoculars). Observing the laser output using optical instruments is dangerous and may damage the eyes.
*3 Laser classification performed based on IEC60825-1 in accordance with FDA (CDRH) Laser Notice.
*4 The measured target is a KEYENCE standard target. Sigma value when the average height of 200 × 200 points in the center of the field of view is measured using the height tool with reciprocating imaging OFF.
*5 The measured target is a KEYENCE standard target. Sigma value when the distance between two circles of 500 points in diameter set 1000 points apart at the center of the field of view on a grayscale image is measured using the circle and circle distance tool with reciprocating imaging OFF.
*6 The measured target is a KEYENCE standard target. Value when the average height of 200 × 200 points is measured using the height tool with reciprocating imaging OFF. See the Dimensions section for the high-accuracy area reference plane.
*7 With YZ range minimum and Y skipping maximum.
*8 Laser ON input is enabled only when connected to a controller.
*9 The maximum value may be exceeded when extreme acceleration is applied.
*10 With an OP cable connected.
*11 When measuring white paper, illuminance on the sensor head receiving surface when light is applied to white paper.
*12 The head needs to be mounted to a metal plate to be used.

Keyence New Stock Image
Keyence LR-ZB250CN Keyence
Sale price $366.08
Only 10 units left

Specifications

Model

LR-ZB250CN

Type

Distance based laser sensor

Appearance

Rectangular

Output

NPN

Cable connection

M8 connector, 4-pin

Detectable distance

35 to 250 mm 1.38" to 9.84" (215 to 0)*1

Standard detectable deviation

35 to 180 mm 1.38" to 7.09": 9 mm 0.35"
180 to 250 mm 7.09" to 9.84": 25 mm 0.98"

Display resolution

1 to 3 (1 to 3 mm 0.04" to 0.12")

Spot size

Approx. 2.4 × 1.2 mm 0.09" × 0.05" at 250 mm 9.84"

Response time

1.5 ms / 10 ms / 50 ms selectable

Light source

Type

Red laser (660 nm)

Laser class

Class 1 laser product
(IEC60825-1, FDA (CDRH) Part1040.10*2)

Function

Indicator

3-digit 7-segment display (red),
output indicator (yellow),
DATUM indicator (orange),
1 spot indicator (green)

Timer

OFF/ON delay/OFF delay/One-shot

Specifications

Power voltage

10 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS

Power consumption

450 mW or less (18 mA or less at 24 V, 34 mA or less at 12 V)

Control output

NPN Open collector,
Applied voltage 30 VDC or less, Control current 100 mA or less,
Residual voltage 1.2 V or less at 10 mA or less, 2 V or less at 10 to 100 mA

Protection circuit

Protection against reverse power connection, output overcurrent, output surge, reverse output connection

Output operation

Light-ON / Dark-ON selectable

External input

Input time calibration: 35 ms or more ON, 35 ms or more OFF
Laser emission stop: 2 ms or more ON, 20 ms or more OFF
Short-circuit current NPN: 1 mA or less/PNP: 2 mA or less

Environmental resistance

Enclosure rating

IP68 (IEC60529), IP69K (DIN40050-9), NEMA 4X, 6P, 13 (NEMA250), ECOLAB*3, Diversey*3

Insulation resistance

20 MΩ or more (500 VDC)

Ambient light

Incandescent lamp: 2,000 lux or less
Sunlight: 4,000 lux or less*4

Ambient temperature

-10 to +50 °C 14 to 122 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Storage temperature

-25 to +75 °C -13 to 167 °F (No freezing)

Withstand voltage

1,000 VAC, 50/60 Hz, 1 min

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

1,000 m/s2, 6 times in each of the X, Y, and Z directions

Material

Case: SUS316L, Display: PES, Lens cover: PMMA with scratch-resistant coating,
Packing/Connector ring: FKM

Accompanying items

Instruction Manual,
Certification/Identification label (FDA)

Weight

Approx. 55 g

*1 Display readings can be used as a guide for the detecting distance. When the setting value is tuned, the readout shifts. When the value exceeds "-99", "-FF" is displayed.
*2 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice.
*3 Have passed resistance tests with cleaning agents from multiple manufactures.
*4 When the response time is 10 ms

LK-G3001V Keyence
Keyence LK-G3001V Keyence
Sale price $1,237.31
In stock, 49 units

Specifications

Model

LK-G3001V*1

Separate type

LK-G3001/LK-GD500*2

Type

All-in-one model

Display

Head compatibility

All LK-G sensor heads are compatible

Number of connectable sensors

Maximum of 2 units

Minimum display unit

0.01 µm

Display range

±9,999.99 mm to ±9,999.99 µm (Selectable from six levels)

Refresh rate

10 times/sec

Terminal block

Analog voltage output

±10 V x 2 outputs, output impedance: 100 Ω

Analog current output

4 to 20 mA x 2 outputs, maximum load resistance: 350 Ω

Timing input

For OUT1, non-voltage input

Reset input

Auto-zero input

Laser remote interlock input

Non-voltage input

Comparator output

For OUT1, NPN open-collector output

Alarm output

For OUT1, NPN open-collector output (N.C.)

Expansion connector

Timing input

For OUT2, non-voltage input

Reset input

Auto-zero input

Program switching input

Non-voltage input x 3 inputs

Laser-Off input

For Head A/Head B, non-voltage input

Comparator output

For OUT2, NPN open-collector output

Alarm output

For OUT2, NPN open-collector output (N.C.)

Binary

Binary output

Measured data output (21 bits), OUT1/OUT2 selectable, NPN open-collector output

Strobe output

NPN open-collector output

Binary selector output

Binary selector input

Non-voltage input

RS-232C interface

Measured data output and control input/output (Maximum baud rate: 115,200 bps, selectable)

USB interface

In conformity with USB Revision 2.0 Full speed (USB1.1 compatible)

Major functions

2 OUT simultaneous measurement, Operation, Averaging, Filter, Calibration, Measurement, AUTO ZERO,
Sampling frequency setting, Mutual interference prevention, Data storage, 8-program memory, ECO mode,
ABLE setting, Target setting, ABLE tuning, Selection of measurement surface of transparent target,
Statistics processing, Connection of setting support software, Selectable head-mounting, etc.

Rating

Power voltage

24 VDC ±10 %, Ripple (P-P) 10 % or less

Current consumption

500 mA or less with 1 head/600 mA or less with 2 heads

Environmental resistance

Ambient temperature

0 to +50 °C 32 to 122 °F

Relative humidity

35 to 85 % RH (No condensation)

Weight

Approx. 480 g

*1 The rating of the NPN open-collector: 50 mA max. (40 V max.), residual voltage of 1 V max.
The rating of non-voltage input: 1 V or less ON voltage, 0.6 mA or less OFF current.
*2 LK-G3001(P) can be operated singly. The measured value display and setting modifications can be performed on the display panel (LK-GD500) or via the setting support software (LK-H1W).

keyence Stock Image
Keyence LJ-S080 Keyence
Sale price$0.00
Sold Out

Specifications

Model

LJ-S080

Reference distance

160 mm 6.30" *1

Measurement range

Z-axis (height)

±23 mm ±0.91" (F.S.=46 mm 1.81")

X-axis (width)

NEAR side

66 mm 2.60"

Reference distance

72 mm 2.83"

FAR side

78 mm 3.07"

Y-axis

Reference distance

160 mm 6.30"

XY data interval

25 μm 0.0010"

Number of XY data points

3200 × 6400

Light source

Laser light source

405 nm (visible light) wavelength blue semiconductor laser

Laser class

Class 2M laser product*2 (IEC 60825-1, FDA (CDRH) Part 1040.10*3)

Output

10 mW

Repeatability

Z-axis (height)

1 μm 0.000039" *4

XY (distance)

3 μm 0.000118" *5

Linearity

Standard area

±0.055% of F.S. *6

High-accuracy area

±0.03% of F.S. *6

Imaging time

Min. 0.2 sec *7

I/F

Ethernet

1000BASE-T, 100BASE-TX

Input

LASER_ON, TRG, MEM_CLEAR *8

Output

READY, EXPOSURE_BUSY, ERROR *8

Ratings

Power voltage

24 VDC +25%, -20%

Current consumption / Power

Max. 4.0 A (at 19.2 V), 3.2 A (at 24 V) *9 / Typ. 17 W

Environmental resistance

Enclosure rating

IP65 (IEC60529) *10

Ambient light

Incandescent lamp: 10000 lux or less *11

Ambient temperature

0 to +45°C 32.0°F to +113.0°F *12

Relative humidity

85% RH or below (no condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.033 G2/Hz; X, Y, and Z directions (IEC 60068-2-64)

Shock resistance

15 G (IEC 60068-2-27)

Material

Aluminum

Weight

Approx. 2600 g 5.73 lb

*1 The reference distance is the distance from the bottom edge of the head to the measurement center of the Z-axis (height). See the Dimensions section for the installation reference plane.
*2 Do not view the beam directly using optical instruments (such as eye loupes, magnifiers, microscopes, telescopes, or binoculars). Observing the laser output using optical instruments is dangerous and may damage the eyes.
*3 Laser classification performed based on IEC60825-1 in accordance with FDA (CDRH) Laser Notice.
*4 The measured target is a KEYENCE standard target. Sigma value when the average height of 200 × 200 points in the center of the field of view is measured using the height tool with reciprocating imaging OFF.
*5 The measured target is a KEYENCE standard target. Sigma value when the distance between two circles of 500 points in diameter set 1000 points apart at the center of the field of view on a grayscale image is measured using the circle and circle distance tool with reciprocating imaging OFF.
*6 The measured target is a KEYENCE standard target. Value when the average height of 200 × 200 points is measured using the height tool with reciprocating imaging OFF. See the Dimensions section for the high-accuracy area reference plane.
*7 With YZ range minimum and Y skipping maximum.
*8 Laser ON input is enabled only when connected to a controller.
*9 The maximum value may be exceeded when extreme acceleration is applied.
*10 With an OP cable connected.
*11 When measuring white paper, illuminance on the sensor head receiving surface when light is applied to white paper.
*12 The head needs to be mounted to a metal plate to be used.

Recently viewed