Filters

Data Acquisition

93 products

Showing 25 - 48 of 93 products

Showing 25 - 48 of 93 products
View
keyence Stock Image
Keyence NR-XH1W Keyence
Sale price$0.00
Sold Out

Specifications

Model

NR-XH1W *1

Applicable models

NR-X100W/NR-500

Supported languages

English, Chinese (Simplified), Japanese

Packaged software

WAVE LOGGER X, LAN TOOL X, File Viewer X

Programming interface

Automation server (WAVE LOGGER X)

Communication interface

USB

Equipped with a USB 2.0 host (Type-A) interface*2

Ethernet

Equipped with a 100 Base-TX interface *3

Wireless LAN

IEEE 802.11b/g/n (with NR-XW1) *3

OS

Windows 11 Home/Pro, Windows 10 Home/Pro/Enterprise or Windows 7 SP1 Home Premium/Professional/Ultimate (pre-installed)*4

CPU

Intel® CoreTM i3 processor (2.0 GHz) or equivalent

Memory capacity

Windows 11: 4 GB or more, Windows 10, Windows 7: 2 GB or more

Required capacity for installation

1 GB or more

Monitor

Resolution: 1280 × 1024 pixels or higher, Display color: High Color (16 bit) or higher

When using the Excel transfer function

Excel 2010 or later must be installed

*1 Windows and Excel are registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries.
*2 Connect the USB directly to the USB port on the PC. Do not use a USB hub or a repeater cable.
*3 Only compatible with the NR-X100W.
*4 32-bit and 64-bit versions supported.

keyence Stock Image
Keyence OP-88627 Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-88626 Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence NR-XJ1 Keyence
Sale price$0.00
Sold Out

Specifications

Model

NR-XJ1

Applicable battery

NR-XB1 Series

Charging part

Charging method

Constant current and constant voltage method

Charging time

1 battery: Approx. 3.0 hours, 2 batteries: Approx. 4.5 hours

Display

Charging confirmation LED

Green LED (Flashing: charging, Constant: charging complete)

Power supply

NR-XU1 AC adapter

Environmental resistance

Ambient temperature

5 to 40°C 41°F to 104°F

Relative humidity

10 to 85% RH (no condensation)

Weight

Approx. 410 g 14.47 oz

keyence Stock Image
Keyence NR-XU15A Keyence
Sale price$0.00
Sold Out

Specifications

Model

NR-XU15A

Battery

Dedicated lithium-ion battery pack NR-XB1 Series × 2

Display LED

Status indicators

Battery operation: Blue, With NR-X100W battery power: Green

Battery level indicator

30% or more remaining: Green, Less than 30% remaining: Red, No remaining battery: Off
Individual displays for 2 battery slots

Battery life (typical example)

Using only the NR-X100W

NR-TH08(P)

Number of connected units / Power consumption: 1
With 1 battery: Approx. 510 min., With 2 batteries: Approx. 1020 min.
Number of connected units / Power consumption: 4
With 1 battery: Approx. 300 min., With 2 batteries: Approx. 600 min.
Number of connected units / Power consumption: 8
With 1 battery: Approx. 200 min., With 2 batteries: Approx. 400 min.
*1

NR-HA08(P)/NR-HV04/NR-ST04

Number of connected units / Power consumption: 1
With 1 battery: Approx. 370 min., With 2 batteries: Approx. 740 min.
Number of connected units / Power consumption: 6
With 1 battery: Approx. 110 min., With 2 batteries: Approx. 220 min.
*1

NR-CA04/NR-FV04

Number of connected units / Power consumption: 1
With 1 battery: Approx. 340 min., With 2 batteries: Approx. 680 min.
Number of connected units / Power consumption: 5
With 1 battery: Approx. 110 min., With 2 batteries: Approx. 220 min.
*1

NR-C512/NR-EN16

Number of connected units / Power consumption: 1
With 1 battery: Approx. 480 min., With 2 batteries: Approx. 960 min.
Number of connected units / Power consumption: 4
With 1 battery: Approx. 260 min., With 2 batteries: Approx. 520 min.
*1*2

Total power consumption of connected units

Number of connected units / Power consumption: At 10 W
With 1 battery: Approx. 190 min., With 2 batteries: Approx. 380 min.
Number of connected units / Power consumption: At 20 W (max. configuration)
With 1 battery: Approx. 110 min., With 2 batteries: Approx. 220 min.
*1

When using remote units and environment-resistant measurement units

Total power consumption of units to be powered by the NR-X100W

Number of connected units / Power consumption: At 10 W
With 1 battery: Approx. 160 min., With 2 batteries: Approx. 320 min.
Number of connected units / Power consumption: At 30 W
With 1 battery: Approx. 70 min., With 2 batteries: Approx. 140 min.
Number of connected units / Power consumption: At 50 W (max. configuration)
With 1 battery: Approx. 40 min., With 2 batteries: Approx. 80 min.
*1

Environmental resistance

Ambient temperature

0 to +40°C 32°F to 104°F*3

Relative humidity

10 to 85% RH (no condensation)

Weight

Approx. 370 g 13.06 oz (Not including NR-XB1A)

*1 The operating time is a typical example with a fully charged new battery. Contact KEYENCE for more information when combining measurement units. When using the NR-XCP30 (or the NR-XW1), the battery duration is found according to the following formula: length of time that the measurement unit is run × total power consumption/(total power consumption + 1.6 W (+1.2 W)).
*2 The NR-EN16 is a typical example when the power output function is not used. However, the power supply output varies when using the power supply output function.
*3 Use between 0 32°F and +35°C 95°F if the total power consumption of the units powered by the NR-X100W exceeds 35 W.

keyence Stock Image
Keyence NR-XTH08T Keyence
Sale price $3,549.99
Only 1 unit left

Specifications

Model

NR-XTH08T

Input method

Insulated single-end input, channels insulated from each other, input channels insulated from the case and other units (system)

Number of input channels

8*1

Input connector type

Miniature thermocouple connector (Universal type)

Measurement cycle

Maximum sampling cycle: 10 ms (100 Hz) to 1 h

A/D converting system

Delta-sigma method

A/D resolution

24 bits

A/D integration time (noise filter)

AUTO (Automatic configuration according to sampling cycle), 2.5 ms (400 Hz), 16.7 ms (60 Hz), 20 ms (50 Hz), 100 ms (10 Hz)

Input type

Thermocouple: K, J, E, T, R, S, B, N, C

Low pass filter

PASS / 200 Hz / 20 Hz

Averaging

Switchable between ON/OFF, Averaging rate: 2 to 128 (moving average)

Reference contact compensation

Switchable between internal and external

Reference contact compensation accuracy

±0.5°C ±0.9°F (23°C ±3°C 73.4°F ±5.4°F at input terminal temperature equilibrium)

Maximum input rating

±30 V*2

Maximum allowable input ground voltage

Dry locations: 30 VAC and 42.4 Vpeak, or 60 VDC
Wet locations: 16 VAC and 22.6 Vpeak, or 35 VDC

Withstand voltage

Between measurement input terminal and case/other units (system): 1000 VAC (50 Hz / 60 Hz) for 1 minute
Between measurement input terminals: 1000 VAC (50 Hz / 60 Hz) for 1 minute

Input impedance

10 MΩ or more

Input signal source resistance

2 kΩ or less

Thermocouple burnout detection

Switchable between ON/OFF, When ON: Approx. 10 μA current detection*3

Measurable range

K: −100 to +1372°C -148°F to +2501.6°F, −200 to −100°C -328°F to -148°F
J: −100 to +1200°C -148°F to +2192°F, −200 to −100°C -328°F to -148°F
E: −100 to +1000°C -148°F to +1832°F, −200 to −100°C -328°F to -148°F
T: −100 to +400°C -148°F to +752°F, −200 to −100°C -328°F to -148°F
N: −100 to +1300°C -148°F to +2372°F, −200 to −100°C -328°F to -148°F
C: 1500 to 2315°C 2732°F to 4199°F, 0 to 1500°C 32°F to 2732°F
R: 300 to 1768°C 572°F to 3214.4°F, 0 to 300°C 32°F to 572°F
S: 300 to 1768°C 572°F to 3214.4°F, 0 to 300°C 32°F to 572°F
B: 400 to 600°C 752°F to 1112°F, 600 to 1820°C 1112°F to 3308°F

Measurement accuracy

K: ±0.04% of rdg ±0.4°C ±0.7°F, ±0.43% of rdg ±0.1°C ±0.2°F
J: ±0.03% of rdg ±0.3°C ±0.5°F, ±0.30% of rdg ±0.1°C ±0.2°F
E: ±0.03% of rdg ±0.3°C ±0.5°F, ±0.27% of rdg ±0.1°C ±0.2°F
T: ±0.4°C ±0.7°F, ±0.34% of rdg ±0.1°C ±0.2°F
N: ±0.02% of rdg ±0.6°C ±2.1°F, ±0.63% of rdg ±0.1°C ±0.2°F
C: ±0.10% of rdg ±0.2°C ±0.4°F, ±0.04% of rdg ±0.8°C ±1.4°F
R: ±0.01% of rdg ±1.2°C ±2.2°F, ±2.0°C ±3.6°F
S: ±0.02% of rdg ±1.2°C ±2.2°F, ±2.0°C ±3.6°F
B: ±2.2°C ±4.0°F, ±1.6°C ±2.9°F
*4

Display resolution

K: 0.05°C 0.09°F
J: 0.05°C 0.09°F
E: 0.05°C 0.09°F
T: 0.01°C 0.02°F
N: 0.05°C 0.09°F
C: 0.05°C 0.09°F
R: 0.05°C 0.09°F
S: 0.05°C 0.09°F
B: 0.05°C 0.09°F

Buffer memory

16M data*5

Warm up time

30 minutes or more

Common mode noise reduction ratio

135 dB or more (up to 60 Hz DC) (typ.) *4

Remote connection

Dedicated environment-resistant remote unit input port × 1 (Remote IN), output port × 1 (Remote OUT)
Connection to NR-X100W master data collection unit or other NR-XR01 remote units using environment-resistant unit cable
Connectable to multiple environment-resistant measurement units*6

Synchronization accuracy between remote connection units

±1 μs*7

Power supply

Supplied from NR-X100W master unit

Power consumption

5.0 W max.

Surrounding air temperature

−40 to +85°C -40°F to +185°F*8

Operating ambient humidity

Max. 100% RH*9

Vibration resistance

100 m/s2 328.1 ft/s2; 5 to 2000 Hz; 2 hours in each of the X, Y, and Z directions (IEC 60068-2-6)*10
Equivalent to JIS D1601 Stage 45 (Class 1, Class 2, and Class 3; equivalent to Class B) automotive vibration standard

Shock resistance

1000 m/s2 3280.8 ft/s2; 3 times in each of the X, Y, and Z directions (18 times in total) (IEC 60068-2-27)

Enclosure rating

IP65/IP67 (IEC 60529)
Enclosure Type 4X (UL 50E, CSA C22.2 No. 94.2, NEMA 250)
Indoor/outdoor use

Material

Main unit case: Aluminum die-casting (coated) / PBT+PC / PC, Display: Reinforced glass,
Connectors: Brass (chromate processing), Connector protection cap: PBT+PC

Weight

Approx. 660 g 23.30 oz

*1 Max. expansion: 64 ch (with 8 units connected, using NR-X100W)
*2 Protection rating against temporary overvoltage. Do not apply voltage directly from an external source.
*3 The time until detection is confirmed varies depending on the acquisition setting and the input signal source resistance. Detection may be disabled depending on the low-pass filter and sampling cycle settings. For details, see P. 5–29.
*4 Does not include reference junction compensation accuracy. Specified with an A/D integration time of 20 ms (50 Hz) / 16.7 ms (60 Hz), the low-pass filter set to PASS, averaging set to 2 times, and after the warm-up time has passed and the temperature has stabilized (23°C ±3°C 73.4°F ±5.4°F).
*5 The buffer memory that can be used by the entire system is limited by the NR-X100W buffer memory.
*6 Environment-resistant unit cables can be extended by connecting an environment-resistant unit extension cable. The total length of cables used in the system should be no more than 100 m 32.8'. The distance between the NR-X100W (or NR-XR01) and environment-resistant measurement units or between environment-resistant remote measurement units should be no more than 60 m 196.9'.
*7 The sampling cycle and timing vary depending on the various measurement units used in the system.
*8 Install the product on the specified mounting sheet metal (OP-88613) for use with ambient temperatures of 80°C 176°F or higher.
*9 Use the product under the condition that the absolute humidity is 85°C 185°F with 90% RH or less. Avoid sudden temperature and humidity changes to prevent significant condensation and freezing.
*10 Testing with a 50 mm 1.97" p-p displacement limit used for 5 to 10 Hz.

keyence Stock Image
Keyence NR-XR01 Keyence
Sale price$0.00
Sold Out

Specifications

Model

NR-XR01

Expansion remote connection

Dedicated remote input port × 1 (Remote IN), Output port × 1 (Remote OUT)
Connection to NR-X100W master data collection unit or other NR-XR01 remote units using a remote unit cable
Daisy-chain connections of multiple remote units allowed*1

Number of connectable measurement units

Max. 8 units*2

Continuous acquisition speed

Max. 100 kHz for all acquisition channels*3

Synchronization between measurement units

±1 μs or less*4

Power supply

Supplied from NR-U5 AC adapter or NR-X100W master data collection unit (operation with no AC adapter)

Power supply

Power consumption

Approx. 2.9 W

Environmental resistance

Ambient temperature

0 to +40°C 32°F to 104°F

Relative humidity

10 to 85% RH (no condensation)

Weight

Approx. 210 g 7.41 oz

*1 Remote unit cables can be extended by connecting a remote extension cable. The total length of remote cables used in the system should be no more than 100 m 328.1'. The distance between the master data collection unit and remote units or between remote units should be no more than 60 m 196.9'.
*2 Use is permitted only if the total power consumption of all connected measurement units is 20 W or less. However, if the remote units are not connected to the NR-U5 AC adapter, the total power consumption must be 10 W or less. The total number of measurement units and remote units for a system varies depending on the system configuration. Refer to “Number of connectable measurement units” in the master data collection unit for more information.
*3 The continuous acquisition speed varies according to the system configuration. Refer to “Continuous acquisition speed” in the master data collection unit for more information.
*4 The sampling cycle and timing vary depending on the connected measurement unit. When using the NR-CA04 in combination with other unit types, a sampling delay may occur between the NR-CA04 and the other units with some setting configurations.

keyence Stock Image
Keyence NR-XHA08T Keyence
Sale price $2,464.99
Only 1 unit left

Specifications

Model

NR-XHA08T

Input method

Insulated single-end input, channels insulated from each other, input channels insulated from the case and other units (system)

Number of input channels

8*1

Input connector type

Dedicated 3-pin connector

Measurement cycle

Maximum sampling cycle: 100 μs (10 kHz) to 60 s

A/D converting system

Delta-sigma method

A/D resolution

24 bits

A/D integration time (noise filter)

AUTO (Automatic configuration according to sampling cycle), 25 μs (40 kHz), 208 μs (4.8 kHz), 2.5 ms (400 Hz), 16.7 ms (60 Hz), 20 ms (50 Hz), 100 ms (10 Hz)

Input frequency band

2 kHz (−3 dB or more)

Input type

Voltage input: ±60 V, ±20 V, ±10 V, ±5 V, ±2 V, ±1 V, ±500 mV, ±200 mV, ±100 mV
Current input: ±20 mA

Averaging

Switchable between ON/OFF, Averaging rate: 2 to 128 (moving average)

Input impedance

Voltage input ±2 V range or higher

1 MΩ ±2%

Voltage input ±1 V range or higher

10 MΩ ±2%

Current input

Approx. 100 Ω

Measurement range

±60 V

Measurable range: −60.000 to +60.000 V
Measurement accuracy: ±0.05% of rdg ±8 mV *2
Display resolution: 2 mV

±20 V

Measurable range: −22.000 to +22.000 V
Measurement accuracy: ±0.05% of rdg ±4 mV *2
Display resolution: 1 mV

±10 V

Measurable range: −11.000 to +11.000 V
Measurement accuracy: ±0.05% of rdg ±2 mV *2
Display resolution: 0.5 mV

±5 V

Measurable range: −5.5000 to +5.5000 V
Measurement accuracy: ±0.05% of rdg ±0.8 mV *2
Display resolution: 0.2 mV

±2 V

Measurable range: −2.2000 to +2.2000 V
Measurement accuracy: ±0.05% of rdg ±0.4 mV *2
Display resolution: 0.1 mV

±1 V

Measurable range: −1.1000 to +1.1000 V
Measurement accuracy: ±0.05% of rdg ±0.2 mV *2
Display resolution: 0.05 mV

±500 mV

Measurable range: −550.00 to +550.00 mV
Measurement accuracy: ±0.05% of rdg ±0.08 mV *2
Display resolution: 0.02 mV

±200 mV

Measurable range: −220.00 to +220.00 mV
Measurement accuracy: ±0.05% of rdg ±0.04 mV *2
Display resolution: 0.01 mV

±100 mV

Measurable range: −110.000 to +110.000 mV
Measurement accuracy: ±0.05% of rdg ±0.02 mV *2
Display resolution: 0.005 mV

±20 mA

Measurable range: −22.000 to +22.000 mA
Measurement accuracy: ±0.08% of rdg ±0.004 mA *2
Display resolution: 0.001 mA

Maximum input rating

Voltage input: ±60 V, Current input: ±30 mA

Maximum allowable input ground voltage

120 VAC and 170 Vpeak, or 120 VDC (when using NR-XHA08T protective grounding)
The following applies when not using NR-XHA08T protective grounding.
Dry locations: 30 VAC and 42.4 Vpeak, or 60 VDC
Wet locations: 16 VAC and 22.6 Vpeak, or 35 VDC

Withstand voltage

Between measurement input terminal and case/other units (system): 1000 VAC (50 Hz / 60 Hz) for 1 minute
Between measurement input terminals: 1000 VAC (50 Hz / 60 Hz) for 1 minute

Buffer memory

16M data*3

Warm up time

30 minutes or more

Residual noise level

0.005% of F.S. (typ.) when A/D integration time is set to 20 ms (50 Hz) / 16.7 ms (60 Hz)
0.05% of F.S. (typ.) when A/D integration time is set to 208 μs (4.8 kHz)
*2

Common mode noise reduction ratio

105 dB or more (up to 60 Hz DC) (typ.)*2

Remote connection

Dedicated environment-resistant remote unit input port × 1 (Remote IN), Output port × 1 (Remote OUT)
Connection to NR-X100W master data collection unit or other NR-XR01 remote units using environment-resistant unit cable
Connectable to multiple environment-resistant measurement units*4

Synchronization accuracy between remote connection units

±1 μs*5

Power supply

Supplied from NR-X100W master unit

Power consumption

5.8 W or less

Surrounding air temperature

−40 to +85°C -40°F to +185°F*6

Operating ambient humidity

Max. 100% RH*7

Vibration resistance

100 m/s2 328.1 ft/s2; 5 to 2000 Hz; 2 hours in each of the X, Y, and Z directions (IEC 60068-2-6)*8
Equivalent to JIS D1601 Stage 45 (Class 1, Class 2, and Class 3; equivalent to Class B) automotive vibration standard

Shock resistance

1000 m/s2 3280.8 ft/s2; 3 times in each of the X, Y, and Z directions (18 times in total) (IEC 60068-2-27)

Enclosure rating

IP65/IP67 (IEC 60529)
Enclosure Type 4X (UL 50E, CSA C22.2 No. 94.2, NEMA 250)
Indoor/outdoor use

Material

Main unit case: Aluminum die-casting (coated), Display: Reinforced glass, Connectors: Brass (chromate processing), Connector protection cap: PBT+PC

Weight

Approx. 690 g 24.36 oz

*1 Max. expansion: 64 ch (with 8 units connected, using NR-X100W)
*2 Specified with an A/D integration time of 20 ms (50 Hz) / 16.7 ms (60 Hz), averaging set to 2 times, and after the warm-up time has passed and the temperature has stabilized (23°C ±3°C 73.4°F ±5.4°F).
*3 The buffer memory that can be used by the entire system is limited by the NR-X100W buffer memory.
*4 Environment-resistant unit cables can be extended by connecting an environment-resistant unit extension cable. The total length of cables used in the system should be no more than 100 m 32.8'. The distance between the NR-X100W (or NR-XR01) and environment-resistant measurement units or between environment-resistant remote measurement units should be no more than 60 m 196.9'.
*5 The sampling cycle and timing vary depending on the various measurement units used in the system.
*6 Install the product on the specified mounting sheet metal (OP-88613) for use with ambient temperatures of 80°C 176°F or higher.
*7 Use the product under the condition that the absolute humidity is 85°C 185°F with 90% RH or less. Avoid sudden temperature and humidity changes to prevent significant condensation and freezing.
*8 Testing with a 50 mm 1.97" p-p displacement limit used for 5 to 10 Hz.

Keyence Stock Image
Keyence NR-XCP30 Keyence
Sale price $2,554.47
Only 3 units left

Specifications

Model

NR-XCP30

Display

3.5" TFT color LCD, 240 × 320 dot

Applicable models

NR-X100W*1

Supported languages

Japanese, English, Chinese (Simplified)

Power supply

Power consumption

1.6 W or less

Environmental resistance

Ambient temperature

0 to +40°C 32°F to 104°F

Relative humidity

10 to 85% RH (no condensation)

Weight

Approx. 290 g 10.24 oz

*1 Cannot be connected to the NR-XR01 remote unit.

keyence Stock Image
Keyence NR-X100W Keyence
Sale price $3,265.99
Only 1 unit left

Specifications

Model

NR-X100W

Main unit buffer memory capacity

50M data*1

Expansion memory

SD card (SD/SDHC)*2

PC interface

USB

USB mini-B connector, USB 2.0 High-speed–compliant, Simultaneous USB connection from one PC to up to four units (switchable by ID switch)

Ethernet

RJ45 connector, 100Base-TX (AUTO MDI/MDIX supported) *3

Wireless LAN

Connection via NR-XW1 wireless LAN unit, IEEE 802.11b/g/n *3

Network function

FTP client function, FTP server function, SNTP client function

Display/operation

Operation via NR-XCP30 control panel, or via WAVE LOGGER X with PC connection

Expansion remote unit connection

Dedicated remote connection connector × 2 (Remote OUT A port, B port)
Unit expansion possible by connecting up to eight NR-XR01 remote units (connected by remote unit cable)

Number of connectable measurement units

Master data collection unit group

Max. 8 units*4

Total with remote units connected

Max. 72 units*5

Continuous acquisition speed

Master data collection unit group

Max. 100 kHz for all acquisition channels *6

Total with remote units connected

Max. 500 kHz for all acquisition channels *6*7

Inter-unit synchronization

Between measurement units in the master data collection unit group

±1 μs or less *8

Between the master data collection unit and each remote unit / environment-resistant measurement unit

Time axis accuracy

±50 ppm (23°C ±3°C 73.4°F ±5.4°F); Same time used for all remote groups, SNTP server time synchronization possible

Synchronous trigger input (SYNC input)

Performance specifications

• Use as external trigger input (normal mode) or synchronous acquisition input (logging mode)
• Non-voltage (contact/non-contact)/voltage input, Falling edge input
• Not insulated from system bus

Input specifications

• For non-voltage input: ON voltage 1.0 V or lower (short circuit current: 1 mA typ.), OFF current 0.1 mA or lower
• For voltage input: ON voltage (Lo) 1.0 V or lower, OFF voltage (Hi) 2.4 V or more, Max. input voltage: 6 V

Control input

Common specifications

• Input type: Bidirectional voltage input
• Maximum rating: 30 VDC, Minimum ON voltage: 10 VDC, Maximum OFF current: 0.2 mA
• Insulation between input and system bus (500 VDC/1 minute)

Individual specifications

• External trigger input (TRG IN): Edge input
• Acquisition start/stop input (START IN): Level input (only enabled in external control mode)
• Auto-balance input (BAL): Edge input (only enabled in external control mode)
• Program selection input 0 to 3 (PROG IN0 to 3): Level input (only enabled in external control mode)

Control output

Common specifications

• Output format: Photo MOS relay output
• Maximum rating: 36 VDC, Output current: 50 mA or less (9-point total: 300 mA or less)
• Leak current at OFF: 0.1 mA or less, Residual voltage when ON: 1 V or less
• Insulation between output and system bus (500 VDC/1 minute)

Individual specifications

• Trigger output (TRG OUT): N.O. output, one-shot output
• System error output (SYS ERR): N.C. output
• Alarm output (ALARM): N.O. output
• Judgment output 1 to 4 (OUT1 to 4): N.O. output
• Ready output (READY): N.O. output

Power supply

• NR-XU1 AC adapter, or 9 to 36 VDC (including ripple) / Max. 72 W (when connected to DC terminal block; at 9 V: 8.0 A or less; at 24 V: 3.0 A or less; at 36 V: 2.0 A or less)
• Battery operation possible when connected to the NR-XU15 Series battery power supply unit

Power supply

Power consumption

8.4 W or less (excluding connected units)

Environmental resistance

Ambient temperature

0 to +40°C 32°F to 104°F

Relative humidity

10 to 85% RH (no condensation)

Weight

Approx. 490 g 17.30 oz (including approx. 10 g 0.35 oz for the OP-88512 (NR-X100W I/O terminal block))

*1 Data is not backed up when the power is turned off. The available data buffer memory per NR-X100W and NR-XR01 group is limited to 25M.
*2 Use only products recommended by KEYENCE (CA-SD4G: 4 GB, CA-SD16G: 16 GB). Using a product not recommended by KEYENCE may result in data not being saved to the SD card during continuous acquisition.
*3 Wired LAN and wireless LAN cannot be used at the same time. When acquiring data from a PC (using WAVE LOGGER X software), use a wired local connection only between the NR-X100W and the PC. Using an onsite local network connection or wireless LAN connection may cause acquisition to stop due to a decrease in transfer speeds caused by network load or wireless LAN communication conditions. The main unit’s automatic saving function allows data to be saved to an SD card in the main unit even if acquisition by PC stops.
*4 Use is permitted only if the total power consumption of all connected measurement units is 20 W or less.
*5 Use is permitted only if the total power consumption of all measurement units, remote units, and environment-resistant measurement units used in the system is 50 W or less when remote units are not connected to an AC adapter.
*6 Acquisition from a PC may not be possible in some PC environments. [Tested conditions] OS: Windows 10 Pro (64 bit), CPU: 3.70 GHz, RAM: 16.0 GB, USB connections: One NR-X100W (no other USB devices), Ethernet connection: One-to-one connection between NR-X100W and PC; Using normal mode and saving in the standard format with a pre-installed OS and running only WAVE LOGGER X. Windows is a registered trademark or a trademark of Microsoft Corporation in the United States and/or other countries.
*7 Each master data collection unit group and remote unit group is limited to 100 kHz for all acquisition channels. When using 5 or more remote units, each remote unit group can have up to 50 kHz per acquisition channel.
*8 The sampling cycle and sampling timing vary depending on the connected measurement unit. When using the NR‑CA04 in combination with other unit types, a sampling delay may occur between the NR-CA04 and the other units with some setting configurations.

keyence Stock Image
Keyence OP-88521 Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-88520 Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-88519 Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-88513 Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-88003 Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-66874 Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-66853 Keyence
Sale price$0.00
Sold Out

Specifications

Model

OP-66853

Type

BNC terminal block*1

*1 Cannot be used in the ±20 mA range.

keyence Stock Image
Keyence OP-51585 Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-51584 Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-51582 Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-51581 Keyence
Sale price$0.00
Sold Out

Specifications

Model

OP-51581

Type

5-pole terminal block

Note

Included with NR-500

keyence Stock Image
Keyence OP-35413 Keyence
Sale price$0.00
Sold Out

Specifications

Model

OP-35413

Type

26-pin connector*1

*1 NR-HA08 included items come pre-wired.

keyence Stock Image
Keyence OP-24423 Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-22186 Keyence
Sale price$0.00
Sold Out

Specifications

Model

OP-22186

Type

MIL connector contact

Applicable product

KV/KZ, KL, HC

Number included

200 units

Note

The special crimping tool for the MIL connector (OP-21734) is necessary for connector crimping.

Recently viewed