TSXSCMCN050 Schneider

This RS485 shielded cable is used to connect 2 safe communication expansion modules. It is designed to link two safe communication modules, in order to create decentralized cabinets of remote IO. This cable figures 2 pairs of twisted conductors with shielding with flying lead connection. RS485 serial interface shielded cables are used between the Bus expansion communication modules to create up to six decentralized safety-related islands with a maximum of 50 meters between each island. It weighs 4.6kg. It measures 50m. It is ideal for monitoring safety functions such as emergency stop, guard monitoring, perimeter guarding, position monitoring, speed monitoring and enabling movement. The Modicon MCM modular safety controller system provide flexibility and scalability from 8 inputs, 2 dual/4 single channel outputs up to 128 inputs, 16 dual/32 single channel outputs, up to 32 or 48 diagnostic status outputs. Modicon MCM modular safety controller system are designed to monitor multiple safety functions on and around a machine to minimise the risk of people accessing the dangerous moving parts of the machine.

Main

Characteristic Value(s)
Range of Product Preventa Safety automation
Accessory / Separate Part Type Connecting cable
Accessory / separate part category Cabling accessory
Accessory / separate part destination RS485 safe communication expansion module

Complementary

Characteristic Value(s)
Product Compatibility XPSMCMCO0000S...
Cable length 164.04 ft (50 m)
Electrical connection Flying leads
AWG Gauge AWG 24
Cable insulation material PE (polyethylene)
Type of cable Twisted pair white/blue
Twisted pair orange/white
Cable shielding type S/FTP
[Ue] rated operational voltage 300 Vrms
Permissible current 2.1 A
Cable capacitance 0.2096 nF between two conductors)
0.3772 nF between conductor and shield)
Attenuation 1.97 dB
Nominal velocity propagation 66 %
Delay skew 1.54 ns
Insulation resistance 24 MOhm nominal conductor DC resistance
2.2 MOhm nominal outer shield DC resistance
Product Weight 10.1 lb(US) (4.6 kg)
Price on request
Ask for quote
   

Notify Me When Available

This RS485 shielded cable is used to connect 2 safe communication expansion modules. It is designed to link two safe communication modules, in order to create decentralized cabinets of remote IO. This cable figures 2 pairs of twisted conductors with shielding with flying lead connection. RS485 serial interface shielded cables are used between the Bus expansion communication modules to create up to six decentralized safety-related islands with a maximum of 50 meters between each island. It weighs 4.6kg. It measures 50m. It is ideal for monitoring safety functions such as emergency stop, guard monitoring, perimeter guarding, position monitoring, speed monitoring and enabling movement. The Modicon MCM modular safety controller system provide flexibility and scalability from 8 inputs, 2 dual/4 single channel outputs up to 128 inputs, 16 dual/32 single channel outputs, up to 32 or 48 diagnostic status outputs. Modicon MCM modular safety controller system are designed to monitor multiple safety functions on and around a machine to minimise the risk of people accessing the dangerous moving parts of the machine.

Main

Characteristic Value(s)
Range of Product Preventa Safety automation
Accessory / Separate Part Type Connecting cable
Accessory / separate part category Cabling accessory
Accessory / separate part destination RS485 safe communication expansion module

Complementary

Characteristic Value(s)
Product Compatibility XPSMCMCO0000S...
Cable length 164.04 ft (50 m)
Electrical connection Flying leads
AWG Gauge AWG 24
Cable insulation material PE (polyethylene)
Type of cable Twisted pair white/blue
Twisted pair orange/white
Cable shielding type S/FTP
[Ue] rated operational voltage 300 Vrms
Permissible current 2.1 A
Cable capacitance 0.2096 nF between two conductors)
0.3772 nF between conductor and shield)
Attenuation 1.97 dB
Nominal velocity propagation 66 %
Delay skew 1.54 ns
Insulation resistance 24 MOhm nominal conductor DC resistance
2.2 MOhm nominal outer shield DC resistance
Product Weight 10.1 lb(US) (4.6 kg)
Characteristic Value(s)
Product Compatibility XPSMCMCO0000S...
Cable length 164.04 ft (50 m)
Electrical connection Flying leads
AWG Gauge AWG 24
Cable insulation material PE (polyethylene)
Type of cable Twisted pair white/blue
Twisted pair orange/white
Cable shielding type S/FTP
[Ue] rated operational voltage 300 Vrms
Permissible current 2.1 A
Cable capacitance 0.2096 nF between two conductors)
0.3772 nF between conductor and shield)
Attenuation 1.97 dB
Nominal velocity propagation 66 %
Delay skew 1.54 ns
Insulation resistance 24 MOhm nominal conductor DC resistance
2.2 MOhm nominal outer shield DC resistance
Product Weight 10.1 lb(US) (4.6 kg)

All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.

If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.

In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.

PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.

Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.

PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.

Trusted By

"Fast service for obsolete parts"

Increasingly PLC/ HMI control platforms are becoming obsolete and parts are no longer supported, however PLC Direct had the HMI we needed and fast shipping for our system to get back online!

Buyer at GE Health

"Helping us move projects forward"

With supply chain issues increasingly affecting our business, PLC Direct has been there for us to supply the PLC products we need, when we need it. If they don't have it readily available, they find it and provide it quickly and reliably. This has helped us move forward with several projects that would have otherwise taken us many, many months to complete.

Buyer at E-Merge Systems – A Rockwell Integrator