Model |
SV2-100L2 |
|||
General specifications |
Capacity |
1.0 kW |
||
Input power supply |
Voltage/frequency |
Main circuit |
3-phase 200 to 240 VAC +10 to -15%, 50/60 Hz |
|
Control circuit |
Single-phase 200 to 240 VAC +10 to -15%, 50/60 Hz |
|||
Allowable frequency fluctuation |
Main circuit/control circuit |
No more than ±5% |
||
Overvoltage category |
III |
|||
Control mode |
Three-phase full-wave rectification, IGBT, PWM control, sine-wave current driving method |
|||
Feedback |
22-bit serial encoder (absolute) communication, |
|||
Operating environment |
Operating atmosphere |
Enclosure rating |
IP20 |
|
Pollution degree |
Pollution degree: 2 (in an IP54 or higher control panel) |
|||
Operating ambient temperature |
-5 to +60°C 23 to 140°F (no freezing; reduced ratings at +55°C 131°F or more) |
|||
Storage ambient temperature |
-20 to +85°C -4 to +185°F (no freezing) |
|||
Operating/storage ambient temperature |
95% RH or less (no condensation) |
|||
Altitude |
2000 m 6561.7' or less above sea level (usable at reduced ratings at 1000 m 3280.8' or more) |
|||
Vibration resistance |
4.9 m/s2 16.1'/s2 (JIS C60068-2-6 compliant) |
|||
Impact resistance |
19.6 m/s2 64.3'/s2 ( JIS C60068-2-27 compliant) |
|||
Other |
No static electricity noise, strong electric fields, magnetic fields, or radiation present |
|||
Min. insulation resistance |
500 VDC, 1 MΩ or more with insulation resistance tester |
|||
Applied standard |
UL/CSA standards |
UL61800-5-1, CSA22.2 No.274 |
||
CE marking |
Low-voltage directive |
EN61800-5-1, EN50178 |
||
EMI |
EN55011 Class A, EN61800-3, EN61000-6-4 |
|||
EMS |
EN61800-3, EN61000-6-2 |
|||
North America EMI standard |
FCC Part15 B, ICES-003. Class A |
|||
Structure |
Type |
Attached to base mount |
||
Safety function |
STO function (STO/EN61800-5-2) |
|||
Safety function |
Safety parameters |
SIL3/EN61508, SIL CL 3/EN62061, |
||
Response time |
8 ms (max.) |
|||
Input |
STO1, STO2: Base block signal for power module |
|||
Output |
EDM: Built-in safety circuit status monitoring (fixed output) |
|||
Applied standard |
EN61800-5-2, EN ISO13849-1: 2008, EN61508, EN62061, EN60204-1, EN61326-3-1 |
|||
Protection function |
Overcurrent, overvoltage, undervoltage, overload, regenerative abnormalities, etc. |
|||
Insulation withstand voltage |
1500 VAC or more (between primary side and ground) |
|||
Weight |
Approx. 1.6 kg |
|||
Power supply/current capacity and power loss |
Main circuit power supply |
Three-phase 200 V |
||
Max. applicable motor capacity |
1.0 kW |
|||
Power supply capacity for 1 amplifier |
Three-phase 200 V: 2.3 kVA |
|||
Output current |
Continuous |
7.6 Arms |
||
Max. |
17 Arms |
|||
Main circuit power loss |
53.6 W |
|||
Regenerative resistor power loss |
8 W |
|||
Control circuit power loss |
17 W |
|||
Total power loss |
78.6 W |
|||
Rated input current |
Main circuit |
Three-phase 200 V: 5.7 Arms |
||
Control circuit |
0.2 Arms |
|||
Rush current |
Main circuit |
34 A |
||
Control circuit | ||||
Performance specifications |
Performance |
Speed control range |
1:5000 (load torque ≤ rated torque conditions) |
|
Speed fluctuation rate |
At load fluctuation |
±0.01% or less with load fluctuations of 0 to 100% (at rated rotation speed) |
||
At main circuit voltage change |
0% with ±10% of rated voltage (at rated rotation speed) |
|||
At ambient temperature change |
±0.1% or less with ambient temperatures of 0 to +50°C 32 to 122°F (at rated rotation speed) |
|||
Torque control accuracy (reproducibility) |
±1% |
|||
Speed frequency response frequency |
2.6 kHz |
|||
Dynamic brake |
Operated at main circuit power supply OFF, servo alarm, limit switch detection (LSP/LSN), forced stop detection (FSTOP) |
|||
Regenerative resistor |
Built-in regenerative resistor: 50 W to 400 W ... not installed |
|||
Display Function |
Panel function |
7-segment LED |
||
Status display LED |
CHARGE: For notification of main circuit power supply input (orange) |
|||
Auxiliary function |
Gain control, alarm history, Z-phase search, etc. |
|||
I/O specifications |
Sequence input signal |
Number of inputs |
7 (3 high-speed input, 4 general input) |
|
Max. input voltage |
28.8 VDC |
|||
Rated input voltage |
24 VDC |
|||
Min. ON voltage |
19 VDC |
|||
Min. OFF current/voltage |
High-speed input: 0.6 mA, general input: 0.3 mA |
|||
Common point mode |
7 points/1 common point (1 terminal) (bidirectional) |
|||
Input time constant |
250 μs, 500 μs, 1 ms, 2.5 ms, 5 ms, 10 ms |
|||
Input current |
High-speed input: 4.5 mA, general input: 3.7 mA |
|||
Input impedance |
Approx. 4.7 kΩ |
|||
Assignable input signals |
Full signal assignment, logic-settable forced stop (FSTOP), |
|||
Sequence output signal |
Number of outputs |
4 |
||
Output mode |
Transistor NPN output |
|||
Rated load |
30 VDC / 50 mA |
|||
Leakage current when OFF |
0.1 mA |
|||
Residual voltage when ON |
1.5 VDC or less |
|||
Common point mode |
Independent common |
|||
Assignable output signals |
Individual signal assignment excluding ALARM signal, logic-settable alarm (ALARM), |
|||
Analog Feedback Input signal monitor |
Max. input voltage |
±12 V |
||
Accuracy |
±1% of F.S. |
|||
Resolution |
±10 bits |
|||
Input impedance |
30 kΩ |
|||
Encoder division pulse output signal |
Output mode |
Phase A (A+/A−), phase B(B+/B−), phase Z (Z+/Z−): Differential line-driver output |
||
Line driver |
SN75ALS174 (T.I.) or equivalent |
|||
Output frequency |
1.6 Mbps (with 2-phase, 4 times multiplication, 6.4 MHz or equivalent) *3 |
|||
Analog monitor output |
No. of channels |
2 ch |
||
Output range |
±10 V (linearity valid range ±8 V) |
|||
Resolution |
16 bits |
|||
Conversion precision |
±20 mV (typ.) |
|||
Max. allowable load current |
±10 mA |
|||
Conversion speed |
1.2 ms (typ.) |
|||
Communication specifications |
MECHATROLINK-III communication |
Communication protocol |
MECHATROLINK-III |
|
Station address |
03H to EFH (Max. number of connectable slaves: 62) |
|||
Transmission speed |
100 Mbps |
|||
Transmission frequency |
125 μs, 250 μs, 500 μs, 750 μs, 1 to 4 ms (in multiples of 0.5 ms) |
|||
Communication cycle |
Support for values starting at transmission frequency × 1 |
|||
Number of transmitted bytes |
32 bytes/station, 48 bytes/station (selectable with slide switch) |
|||
Transmission media/cable |
Category 5e-compliant, STP cross cable |
|||
Operating specifications |
Position control / speed control / torque control |
|||
Command input |
MECHATROLINK-III command |
|||
Max. transmission distance |
50 m 164.0' *4 |
|||
USB communication |
Connected device |
PC |
||
Communication standard |
USB 2.0-compliant |
|||
Function |
Status display, parameter setting, tuning, etc. |
|||
*1 When using a DC power supply input, set “*AC/DC power supply” to “DC”. | ||||
All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.
If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.
In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.
PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.
Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.
PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.

Trusted By
Need More?
Contact Us
we're here to support your business.

"Fast service for obsolete parts"
Increasingly PLC/ HMI control platforms are becoming obsolete and parts are no longer supported, however PLC Direct had the HMI we needed and fast shipping for our system to get back online!
Buyer at GE Health

"Helping us move projects forward"
With supply chain issues increasingly affecting our business, PLC Direct has been there for us to supply the PLC products we need, when we need it. If they don't have it readily available, they find it and provide it quickly and reliably. This has helped us move forward with several projects that would have otherwise taken us many, many months to complete.
Buyer at E-Merge Systems – A Rockwell Integrator