METSEPM2110 Schneider

This device is a panel mount or flush mount power meter with a 96mm by 96mm bezel size having 3 rows of bright red 4 digits 14.2 mm height LED display. The meter measures active energy as per accuracy class Class 1.0 complying to IEC 62053-21 standard with sampling rate of 64 samples per cycle. Able to measures all three vectors of power and energy such as Active, Apparent & Reactive beside Voltages, Current, Frequency and Power Factor. Plus the total Harmonic Distortion for both current and volrage on per phase basis. The meter will function in either 50Hz or 60Hz network frequency and accepts universal control power voltages ranging from 44 to 300 V Line to Neutral AC or DC voltages. Rated current for this meter is either 1A or 5A input. it supports up to 13 different types of wiring schemes under Single Phase, Two Phase or Three Phase configuration types. The range of measurement voltage between Phases is 35 to 480 V Line to Line AC at 45 to 65 Hz while it is 20 to 277 V between Line and Neutral. The meter also has one digital pulse output for any energy parameters congigurable to different energy scaling. Product dimensions are as follows: width 3.78 in (96 mm), depth 2.16 in (54 mm), height 3.78 in (96 mm) and product weight 10.58 oz (300 g).

Main

Characteristic Value(s)
Range EasyLogic
product name EasyLogic PM2100
Product or Component Type Power meter
Device short name PM2110

Complementary

Characteristic Value(s)
Device Application Power monitoring
Sub billing
Power quality analysis total harmonic distortion
Type of measurement Total current harmonic distortion THD (I) per phase
Total voltage harmonic distortion THD (U) per phase
Apparent energy total
Active and reactive energy total
Apparent power total
Active and reactive power total
Current average
Voltage average
Frequency average
Power factor average
Metering type Peak demand power PM, QM, SM
Apparent power S, S1, S2, S3
Current I, I1, I2, I3
Reactive power Q, Q1, Q2, Q3
Calculated neutral current
Voltage U, U21, U32, U13, V, V1, V2, V3
Peak demand currents
Unbalance current
Demand power P, Q, S
Active power P, P1, P2, P3
Active, reactive, apparent energy (signed, four quadrant)
Accuracy class Class 1 active energy IEC 62053-21
Class 1 reactive energy IEC 62053-24
Measurement accuracy Apparent power +/- 1 %
Active energy +/- 1 %
Reactive energy +/- 1 %
Active power +/- 1 %
Voltage +/- 0.5 %
Power factor +/- 0.01
Current +/- 0.5 %
Frequency +/- 0.05 %
Measurement current 5…6000 mA
Measurement voltage 35…480 V AC 50/60 Hz between phases
20…277 V AC 50/60 Hz between phase and neutral
480…999000 V AC 50/60 Hz with external VT
Frequency measurement range 45…65 Hz
[Us] rated supply voltage 44...277 V AC 45...65 Hz +/- 10 %
44...277 V DC +/- 10 %
Network Frequency 60 Hz
50 Hz
Ride-through time 100 ms 120 V AC typical
400 ms 230 V AC typical
50 ms 125 V DC typical
Line Rated Current 5 A
1 A
Maximum power consumption in VA 6 VA 277 V AC
Maximum power consumption in W 3.3 W power lines (AC))
2 W 277 V power lines (DC))
input impedance Current (impedance <= 0.3 mOhm)
Voltage (impedance > 5 MOhm)
Tamperproof of settings Protected by access code
Display Type 7 segments LED
Display colour Red
Messages display capacity 3 fields of 4 characters
Display digits 12 - 0.6 in (14.2 mm)
Demand intervals Configurable from 1 to 60 min
Information displayed Demand current past value)
Demand current present value)
Demand power past value)
Demand power present value)
Voltage
Current
Frequency
Energy consumption
Harmonic distortion
Power factor
Active power
Apparent power
Reactive power
Unbalanced in %
Control type 3 x button
Local signalling Red LED output signal 1...9999000 pulse/ k_h (kWh, kVAh, kVARh)
Green LED module operating (RUN)
Number of inputs 0
Number of Outputs 1 pulse
POP parameter 20 ms 5...40 V DC, 20 mA 1...9999000 pulse/ k_h (kWh, kVAh, kVARh)
Impulse duration 20 ms
Communication port protocol POP
Sampling rate 64 samples/cycle
Cybersecurity Enable/disable communication ports
Communication Service Remote monitoring
Product certifications CE conforming to IEC 61010-1
CULus conforming to UL 61010-1
CULus conforming to CSA C22.2 No 61010-1
RCM
EAC
C-tick
Mounting Mode Clip-on
Mounting position Vertical
Mounting support Framework
Provided equipment 1 x Installation guide
Measurement category Category III 480 V
Category II 480…600 V
Electrical Insulation Class Double insulation
Class II
Flame retardance V-0 conforming to UL 94
Connections - terminals Current transformer screw connection bottom) 6
Voltage inputs screw connection top) 4
Material Polycarbonate
Width 3.8 in (96 mm)
Depth Total : 3.00 in (76.09 mm)
Embedded : 2.43 in (61.64 mm)
Height 3.8 in (96 mm)
Product Weight 10.6 oz (300 g)
Compatibility code PM2110
Est. delivery between and    
Estimated delivery dates are estimates only. Int'l customers allow a few more days. For more precise delivery estimates, please contact us at support@plc-direct.com. Contact us in advance for expedited shipping options.
Sale price$825.00
1-year warranty
FREE WORDWIDE SHIPPING
Condition:
$0.00
$825.00
$0.00
Ach Direct Debit American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa

This device is a panel mount or flush mount power meter with a 96mm by 96mm bezel size having 3 rows of bright red 4 digits 14.2 mm height LED display. The meter measures active energy as per accuracy class Class 1.0 complying to IEC 62053-21 standard with sampling rate of 64 samples per cycle. Able to measures all three vectors of power and energy such as Active, Apparent & Reactive beside Voltages, Current, Frequency and Power Factor. Plus the total Harmonic Distortion for both current and volrage on per phase basis. The meter will function in either 50Hz or 60Hz network frequency and accepts universal control power voltages ranging from 44 to 300 V Line to Neutral AC or DC voltages. Rated current for this meter is either 1A or 5A input. it supports up to 13 different types of wiring schemes under Single Phase, Two Phase or Three Phase configuration types. The range of measurement voltage between Phases is 35 to 480 V Line to Line AC at 45 to 65 Hz while it is 20 to 277 V between Line and Neutral. The meter also has one digital pulse output for any energy parameters congigurable to different energy scaling. Product dimensions are as follows: width 3.78 in (96 mm), depth 2.16 in (54 mm), height 3.78 in (96 mm) and product weight 10.58 oz (300 g).

Main

Characteristic Value(s)
Range EasyLogic
product name EasyLogic PM2100
Product or Component Type Power meter
Device short name PM2110

Complementary

Characteristic Value(s)
Device Application Power monitoring
Sub billing
Power quality analysis total harmonic distortion
Type of measurement Total current harmonic distortion THD (I) per phase
Total voltage harmonic distortion THD (U) per phase
Apparent energy total
Active and reactive energy total
Apparent power total
Active and reactive power total
Current average
Voltage average
Frequency average
Power factor average
Metering type Peak demand power PM, QM, SM
Apparent power S, S1, S2, S3
Current I, I1, I2, I3
Reactive power Q, Q1, Q2, Q3
Calculated neutral current
Voltage U, U21, U32, U13, V, V1, V2, V3
Peak demand currents
Unbalance current
Demand power P, Q, S
Active power P, P1, P2, P3
Active, reactive, apparent energy (signed, four quadrant)
Accuracy class Class 1 active energy IEC 62053-21
Class 1 reactive energy IEC 62053-24
Measurement accuracy Apparent power +/- 1 %
Active energy +/- 1 %
Reactive energy +/- 1 %
Active power +/- 1 %
Voltage +/- 0.5 %
Power factor +/- 0.01
Current +/- 0.5 %
Frequency +/- 0.05 %
Measurement current 5…6000 mA
Measurement voltage 35…480 V AC 50/60 Hz between phases
20…277 V AC 50/60 Hz between phase and neutral
480…999000 V AC 50/60 Hz with external VT
Frequency measurement range 45…65 Hz
[Us] rated supply voltage 44...277 V AC 45...65 Hz +/- 10 %
44...277 V DC +/- 10 %
Network Frequency 60 Hz
50 Hz
Ride-through time 100 ms 120 V AC typical
400 ms 230 V AC typical
50 ms 125 V DC typical
Line Rated Current 5 A
1 A
Maximum power consumption in VA 6 VA 277 V AC
Maximum power consumption in W 3.3 W power lines (AC))
2 W 277 V power lines (DC))
input impedance Current (impedance <= 0.3 mOhm)
Voltage (impedance > 5 MOhm)
Tamperproof of settings Protected by access code
Display Type 7 segments LED
Display colour Red
Messages display capacity 3 fields of 4 characters
Display digits 12 - 0.6 in (14.2 mm)
Demand intervals Configurable from 1 to 60 min
Information displayed Demand current past value)
Demand current present value)
Demand power past value)
Demand power present value)
Voltage
Current
Frequency
Energy consumption
Harmonic distortion
Power factor
Active power
Apparent power
Reactive power
Unbalanced in %
Control type 3 x button
Local signalling Red LED output signal 1...9999000 pulse/ k_h (kWh, kVAh, kVARh)
Green LED module operating (RUN)
Number of inputs 0
Number of Outputs 1 pulse
POP parameter 20 ms 5...40 V DC, 20 mA 1...9999000 pulse/ k_h (kWh, kVAh, kVARh)
Impulse duration 20 ms
Communication port protocol POP
Sampling rate 64 samples/cycle
Cybersecurity Enable/disable communication ports
Communication Service Remote monitoring
Product certifications CE conforming to IEC 61010-1
CULus conforming to UL 61010-1
CULus conforming to CSA C22.2 No 61010-1
RCM
EAC
C-tick
Mounting Mode Clip-on
Mounting position Vertical
Mounting support Framework
Provided equipment 1 x Installation guide
Measurement category Category III 480 V
Category II 480…600 V
Electrical Insulation Class Double insulation
Class II
Flame retardance V-0 conforming to UL 94
Connections - terminals Current transformer screw connection bottom) 6
Voltage inputs screw connection top) 4
Material Polycarbonate
Width 3.8 in (96 mm)
Depth Total : 3.00 in (76.09 mm)
Embedded : 2.43 in (61.64 mm)
Height 3.8 in (96 mm)
Product Weight 10.6 oz (300 g)
Compatibility code PM2110
Characteristic Value(s)
Device Application Power monitoring
Sub billing
Power quality analysis total harmonic distortion
Type of measurement Total current harmonic distortion THD (I) per phase
Total voltage harmonic distortion THD (U) per phase
Apparent energy total
Active and reactive energy total
Apparent power total
Active and reactive power total
Current average
Voltage average
Frequency average
Power factor average
Metering type Peak demand power PM, QM, SM
Apparent power S, S1, S2, S3
Current I, I1, I2, I3
Reactive power Q, Q1, Q2, Q3
Calculated neutral current
Voltage U, U21, U32, U13, V, V1, V2, V3
Peak demand currents
Unbalance current
Demand power P, Q, S
Active power P, P1, P2, P3
Active, reactive, apparent energy (signed, four quadrant)
Accuracy class Class 1 active energy IEC 62053-21
Class 1 reactive energy IEC 62053-24
Measurement accuracy Apparent power +/- 1 %
Active energy +/- 1 %
Reactive energy +/- 1 %
Active power +/- 1 %
Voltage +/- 0.5 %
Power factor +/- 0.01
Current +/- 0.5 %
Frequency +/- 0.05 %
Measurement current 5…6000 mA
Measurement voltage 35…480 V AC 50/60 Hz between phases
20…277 V AC 50/60 Hz between phase and neutral
480…999000 V AC 50/60 Hz with external VT
Frequency measurement range 45…65 Hz
[Us] rated supply voltage 44...277 V AC 45...65 Hz +/- 10 %
44...277 V DC +/- 10 %
Network Frequency 60 Hz
50 Hz
Ride-through time 100 ms 120 V AC typical
400 ms 230 V AC typical
50 ms 125 V DC typical
Line Rated Current 5 A
1 A
Maximum power consumption in VA 6 VA 277 V AC
Maximum power consumption in W 3.3 W power lines (AC))
2 W 277 V power lines (DC))
input impedance Current (impedance <= 0.3 mOhm)
Voltage (impedance > 5 MOhm)
Tamperproof of settings Protected by access code
Display Type 7 segments LED
Display colour Red
Messages display capacity 3 fields of 4 characters
Display digits 12 - 0.6 in (14.2 mm)
Demand intervals Configurable from 1 to 60 min
Information displayed Demand current past value)
Demand current present value)
Demand power past value)
Demand power present value)
Voltage
Current
Frequency
Energy consumption
Harmonic distortion
Power factor
Active power
Apparent power
Reactive power
Unbalanced in %
Control type 3 x button
Local signalling Red LED output signal 1...9999000 pulse/ k_h (kWh, kVAh, kVARh)
Green LED module operating (RUN)
Number of inputs 0
Number of Outputs 1 pulse
POP parameter 20 ms 5...40 V DC, 20 mA 1...9999000 pulse/ k_h (kWh, kVAh, kVARh)
Impulse duration 20 ms
Communication port protocol POP
Sampling rate 64 samples/cycle
Cybersecurity Enable/disable communication ports
Communication Service Remote monitoring
Product certifications CE conforming to IEC 61010-1
CULus conforming to UL 61010-1
CULus conforming to CSA C22.2 No 61010-1
RCM
EAC
C-tick
Mounting Mode Clip-on
Mounting position Vertical
Mounting support Framework
Provided equipment 1 x Installation guide
Measurement category Category III 480 V
Category II 480…600 V
Electrical Insulation Class Double insulation
Class II
Flame retardance V-0 conforming to UL 94
Connections - terminals Current transformer screw connection bottom) 6
Voltage inputs screw connection top) 4
Material Polycarbonate
Width 3.8 in (96 mm)
Depth Total : 3.00 in (76.09 mm)
Embedded : 2.43 in (61.64 mm)
Height 3.8 in (96 mm)
Product Weight 10.6 oz (300 g)
Compatibility code PM2110

All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.

If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.

In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.

PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.

Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.

PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.

Trusted By

"Fast service for obsolete parts"

Increasingly PLC/ HMI control platforms are becoming obsolete and parts are no longer supported, however PLC Direct had the HMI we needed and fast shipping for our system to get back online!

Buyer at GE Health

"Helping us move projects forward"

With supply chain issues increasingly affecting our business, PLC Direct has been there for us to supply the PLC products we need, when we need it. If they don't have it readily available, they find it and provide it quickly and reliably. This has helped us move forward with several projects that would have otherwise taken us many, many months to complete.

Buyer at E-Merge Systems – A Rockwell Integrator