METSEION93040 Schneider

The PowerLogic ION9000 is your 24/7 power quality expert, providing information, not just data. A comprehensive, industry-leading Power Quality Instrument (PQI-A) certified to IEC 62586-1/-2 ensures reliable, precision performance that is perfect for both supply and demand side applications. Third-party lab verified accuracy to Class 0.1S (ANSI C12.20, IEC 62053-22). Highly customizable and modular, ION technology programmability and field installable option modules can satisfy any solution, protecting your investment now and into the future. Providing power quality analysis according to both EN 50160 and IEEE 519, and patented Disturbance Direction Detection, you become a PQ expert and will be able to respond rapidly to system events. Cybersecurity features include secure protocols (HTTPS, SFTP), security event logging, Syslog protocol, ability to enable/disable communication ports, and 50 user configurable accounts. With 2 GB of memory to support 50 data logs, 50+ user-definable alarms, disturbance and transient waveforms. 1/2 cycle RMS logging, custom web pages, min/max logs, energy trends, and Time of Use. The ability to timestamp events to +/-1 ms utilizing time synchronization method that include PTP (IEEE1588), NTP, IRIG-B, GPS ASCII (RS485) and network time set function. 8 digital inputs, 4 digital outputs and 2 relay outputs, plus the ability to add up to 4 option modules. Option modules include 2 relays and 6 digital inputs or 2 analog outputs and 4 analog inputs. Ability to capture power quality events as short as 20 µs and record both waveforms and 1/2-cycle RMS concurrently on any event. Voltage inputs of 100 to 690 V between phases; Current inputs with low voltage transducer; Frequency of 20-450 Hz. Wide control power range of 90 to 480 VAC or 110 to 480 VDC. DIN rail mounting with remote display and panel mounting (with back to back adapter), plus 2 display options, further enhance the flexibility and adaptability of the ION9000.

Main

Characteristic Value(s)
Range PowerLogic
Product or Component Type Energy and power quality meter
Device short name ION93040
product name PowerLogic ION9000
Device Application Power monitoring
WAGES metering
Net metering
Medium voltage
High voltage
Metering type Demand current I1, I2, I3, I4, I5
Peak demand currents
Demand power P, Q, S
Peak demand power PM, QM, SM
Calculated active and reactive energy (+/- W.h, +/- VAR.h)
Provided Equipment Remote display
Remote display adapter
Mounting instructions
Mounting Hardware

Complementary

Characteristic Value(s)
Power quality analysis EN 50160 compliance checking
IEEE 519 harmonic limit
IEC 61000-4-30 class A compliance reporting
IEEE 519 compliance reporting
waveform capture
total demand distortion
total harmonic distortion
up to the 63rd harmonic
up to the 127th harmonic with software
disturbance direction detection
dip, swell and transient
half cycle data acquisition
transient detection (20 µs)
Type of measurement Voltage sags and swells
Current sags and swells
Voltage
Current
Frequency
Active and reactive power total
Apparent power total
Active and reactive power per phase
Apparent power per phase
Power factor total
Power factor per phase
Active and reactive energy
Apparent energy
Harmonic distorsion (I THD & U THD)
[Us] rated supply voltage 90...480 V AC 45...66 Hz +/- 10 %
90...120 V AC 400 Hz +/- 10 %
110...480 V DC +/- 10 %
Network Frequency 50 Hz
60 Hz
Ride-through time 100 ms 6 cycles at 60 Hz 120 V AC typical
400 ms 24 cycles at 60 Hz 240 V AC typical
1200 ms 72 cycles at 60 Hz 480 V AC typical
type of network 3P + N + E
Power consumption in VA 38 VA 480 V AC
Maximum power consumption in VA 80 VA 480 V AC
Display Resolution 800 x 480 pixels
Display Type Remote LCD display
Colour touchscreen
Sampling rate 1024 samples/cycle
input type Voltage (impedance 5 MOhm)
Split core current transducer (impedance 200 kOhm)5 x
Measurement voltage 57…400 V AC 42...69 Hz between phase and neutral
100…690 V AC 42...69 Hz between phases
Frequency measurement range 20…450 Hz
Number of inputs 8 digital 30 V AC/60 V DC
Measurement accuracy Voltage +/- 0.1 %
Current +/- 0.1 %
Accuracy class Class 0.1S active energy IEC 62053-22
Class 0.1 active energy IEC 61557-12
Class 0.1 active energy ANSI C12.20
Class 0.5S reactive energy IEC 62053-24
Class 0.1 current IEC 61557-12
Class 0.1 voltage IEC 61557-12
Class 0.1 active power IEC 61557-12
Class 0.5 power factor IEC 61557-12
Number of Outputs 4 digital
2 form C relay output
Communication port protocol Modbus RTU 2400...115200 bps - 2-wire
ION 2400...115200 bps - 2-wire
DNP3 2400...115200 bps - 2-wire
Modbus TCP 10/100 Mbit/s
ION TCP 10/100 Mbit/s
DNP3 TCP 10/100 Mbit/s
IEC 61850
Ethernet Modbus TCP/IP daisy chain 10/100 Mbit/s
DHCP
DNS
DLMS
Communication port support 2 RS485 removable screw terminal block
Port Ethernet 10/100BASE-TX 2 RJ45
Communication gateway Ethernet/serial
Time synchronisation protocol GPS
IRIG-B
NTP
SNTP
PTP
Data recording Time stamping
Min/max of instantaneous values
User-definable data logs
Continuous logging or snapshot
Trending/forecasting
Event logs
Alarm logs
Configuration change
Power outage
User login/logout
Data logs
GPS synchronisation
Sequence of event recording
Memory capacity 2 GB
Cybersecurity Syslog protocol support
Robust security logs
Port hardening
Enable/disable communication ports
Hardware metrology lock
Web services Viewing of captured waveform
Web page
Pass/fail report for IEEE 519
Pass/fail report for EN 50160
ITIC (CBEMA) curve
SEMI curve
NEMA motor derating curve
Alarm notification by e-mail
TLS 1.2
Push historical data via mail
Ethernet service DHCP client
Device Profile Web Services (DPWS)
Rapid Scanning Tree Protocol (RSTP)
FTP/HTTP/HTTPS
Communication Service Compliant reports
Power quality summary
Energy report
EcoStruxure Power Events Analysis
SMTP e-mail notification
SNMP
Tamperproof of settings Protected by sealable cover
Mounting support DIN rail meter device
Door cut-out remote display
Electrical insulation class Class III EN/IEC 62052-11
Isolation voltage III400…690 V conforming to EN 61010-1:ed. 3
III347…600 V conforming to UL 61010-1:ed. 3
III347…600 V conforming to CSA C22.2 No 61010-1:ed. 3
Width 6.3 in (160 mm)
Depth 5.3 in (135.3 mm)
Height 6.3 in (160 mm)
Product Weight 3.3 lb(US) (1.5 kg)
Market Segment Data center
Healthcare
Semiconductor
Pharmaceutical
Chemical
Energy
Mining
Est. delivery between and    
Estimated delivery dates are estimates only. Int'l customers allow a few more days. For more precise delivery estimates, please contact us at support@plc-direct.com. Contact us in advance for expedited shipping options.
Sale price$20,236.50
1-year warranty
FREE WORDWIDE SHIPPING
Condition:
$0.00
$20,236.50
$0.00
Ach Direct Debit American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa

The PowerLogic ION9000 is your 24/7 power quality expert, providing information, not just data. A comprehensive, industry-leading Power Quality Instrument (PQI-A) certified to IEC 62586-1/-2 ensures reliable, precision performance that is perfect for both supply and demand side applications. Third-party lab verified accuracy to Class 0.1S (ANSI C12.20, IEC 62053-22). Highly customizable and modular, ION technology programmability and field installable option modules can satisfy any solution, protecting your investment now and into the future. Providing power quality analysis according to both EN 50160 and IEEE 519, and patented Disturbance Direction Detection, you become a PQ expert and will be able to respond rapidly to system events. Cybersecurity features include secure protocols (HTTPS, SFTP), security event logging, Syslog protocol, ability to enable/disable communication ports, and 50 user configurable accounts. With 2 GB of memory to support 50 data logs, 50+ user-definable alarms, disturbance and transient waveforms. 1/2 cycle RMS logging, custom web pages, min/max logs, energy trends, and Time of Use. The ability to timestamp events to +/-1 ms utilizing time synchronization method that include PTP (IEEE1588), NTP, IRIG-B, GPS ASCII (RS485) and network time set function. 8 digital inputs, 4 digital outputs and 2 relay outputs, plus the ability to add up to 4 option modules. Option modules include 2 relays and 6 digital inputs or 2 analog outputs and 4 analog inputs. Ability to capture power quality events as short as 20 µs and record both waveforms and 1/2-cycle RMS concurrently on any event. Voltage inputs of 100 to 690 V between phases; Current inputs with low voltage transducer; Frequency of 20-450 Hz. Wide control power range of 90 to 480 VAC or 110 to 480 VDC. DIN rail mounting with remote display and panel mounting (with back to back adapter), plus 2 display options, further enhance the flexibility and adaptability of the ION9000.

Main

Characteristic Value(s)
Range PowerLogic
Product or Component Type Energy and power quality meter
Device short name ION93040
product name PowerLogic ION9000
Device Application Power monitoring
WAGES metering
Net metering
Medium voltage
High voltage
Metering type Demand current I1, I2, I3, I4, I5
Peak demand currents
Demand power P, Q, S
Peak demand power PM, QM, SM
Calculated active and reactive energy (+/- W.h, +/- VAR.h)
Provided Equipment Remote display
Remote display adapter
Mounting instructions
Mounting Hardware

Complementary

Characteristic Value(s)
Power quality analysis EN 50160 compliance checking
IEEE 519 harmonic limit
IEC 61000-4-30 class A compliance reporting
IEEE 519 compliance reporting
waveform capture
total demand distortion
total harmonic distortion
up to the 63rd harmonic
up to the 127th harmonic with software
disturbance direction detection
dip, swell and transient
half cycle data acquisition
transient detection (20 µs)
Type of measurement Voltage sags and swells
Current sags and swells
Voltage
Current
Frequency
Active and reactive power total
Apparent power total
Active and reactive power per phase
Apparent power per phase
Power factor total
Power factor per phase
Active and reactive energy
Apparent energy
Harmonic distorsion (I THD & U THD)
[Us] rated supply voltage 90...480 V AC 45...66 Hz +/- 10 %
90...120 V AC 400 Hz +/- 10 %
110...480 V DC +/- 10 %
Network Frequency 50 Hz
60 Hz
Ride-through time 100 ms 6 cycles at 60 Hz 120 V AC typical
400 ms 24 cycles at 60 Hz 240 V AC typical
1200 ms 72 cycles at 60 Hz 480 V AC typical
type of network 3P + N + E
Power consumption in VA 38 VA 480 V AC
Maximum power consumption in VA 80 VA 480 V AC
Display Resolution 800 x 480 pixels
Display Type Remote LCD display
Colour touchscreen
Sampling rate 1024 samples/cycle
input type Voltage (impedance 5 MOhm)
Split core current transducer (impedance 200 kOhm)5 x
Measurement voltage 57…400 V AC 42...69 Hz between phase and neutral
100…690 V AC 42...69 Hz between phases
Frequency measurement range 20…450 Hz
Number of inputs 8 digital 30 V AC/60 V DC
Measurement accuracy Voltage +/- 0.1 %
Current +/- 0.1 %
Accuracy class Class 0.1S active energy IEC 62053-22
Class 0.1 active energy IEC 61557-12
Class 0.1 active energy ANSI C12.20
Class 0.5S reactive energy IEC 62053-24
Class 0.1 current IEC 61557-12
Class 0.1 voltage IEC 61557-12
Class 0.1 active power IEC 61557-12
Class 0.5 power factor IEC 61557-12
Number of Outputs 4 digital
2 form C relay output
Communication port protocol Modbus RTU 2400...115200 bps - 2-wire
ION 2400...115200 bps - 2-wire
DNP3 2400...115200 bps - 2-wire
Modbus TCP 10/100 Mbit/s
ION TCP 10/100 Mbit/s
DNP3 TCP 10/100 Mbit/s
IEC 61850
Ethernet Modbus TCP/IP daisy chain 10/100 Mbit/s
DHCP
DNS
DLMS
Communication port support 2 RS485 removable screw terminal block
Port Ethernet 10/100BASE-TX 2 RJ45
Communication gateway Ethernet/serial
Time synchronisation protocol GPS
IRIG-B
NTP
SNTP
PTP
Data recording Time stamping
Min/max of instantaneous values
User-definable data logs
Continuous logging or snapshot
Trending/forecasting
Event logs
Alarm logs
Configuration change
Power outage
User login/logout
Data logs
GPS synchronisation
Sequence of event recording
Memory capacity 2 GB
Cybersecurity Syslog protocol support
Robust security logs
Port hardening
Enable/disable communication ports
Hardware metrology lock
Web services Viewing of captured waveform
Web page
Pass/fail report for IEEE 519
Pass/fail report for EN 50160
ITIC (CBEMA) curve
SEMI curve
NEMA motor derating curve
Alarm notification by e-mail
TLS 1.2
Push historical data via mail
Ethernet service DHCP client
Device Profile Web Services (DPWS)
Rapid Scanning Tree Protocol (RSTP)
FTP/HTTP/HTTPS
Communication Service Compliant reports
Power quality summary
Energy report
EcoStruxure Power Events Analysis
SMTP e-mail notification
SNMP
Tamperproof of settings Protected by sealable cover
Mounting support DIN rail meter device
Door cut-out remote display
Electrical insulation class Class III EN/IEC 62052-11
Isolation voltage III400…690 V conforming to EN 61010-1:ed. 3
III347…600 V conforming to UL 61010-1:ed. 3
III347…600 V conforming to CSA C22.2 No 61010-1:ed. 3
Width 6.3 in (160 mm)
Depth 5.3 in (135.3 mm)
Height 6.3 in (160 mm)
Product Weight 3.3 lb(US) (1.5 kg)
Market Segment Data center
Healthcare
Semiconductor
Pharmaceutical
Chemical
Energy
Mining
Characteristic Value(s)
Power quality analysis EN 50160 compliance checking
IEEE 519 harmonic limit
IEC 61000-4-30 class A compliance reporting
IEEE 519 compliance reporting
waveform capture
total demand distortion
total harmonic distortion
up to the 63rd harmonic
up to the 127th harmonic with software
disturbance direction detection
dip, swell and transient
half cycle data acquisition
transient detection (20 µs)
Type of measurement Voltage sags and swells
Current sags and swells
Voltage
Current
Frequency
Active and reactive power total
Apparent power total
Active and reactive power per phase
Apparent power per phase
Power factor total
Power factor per phase
Active and reactive energy
Apparent energy
Harmonic distorsion (I THD & U THD)
[Us] rated supply voltage 90...480 V AC 45...66 Hz +/- 10 %
90...120 V AC 400 Hz +/- 10 %
110...480 V DC +/- 10 %
Network Frequency 50 Hz
60 Hz
Ride-through time 100 ms 6 cycles at 60 Hz 120 V AC typical
400 ms 24 cycles at 60 Hz 240 V AC typical
1200 ms 72 cycles at 60 Hz 480 V AC typical
type of network 3P + N + E
Power consumption in VA 38 VA 480 V AC
Maximum power consumption in VA 80 VA 480 V AC
Display Resolution 800 x 480 pixels
Display Type Remote LCD display
Colour touchscreen
Sampling rate 1024 samples/cycle
input type Voltage (impedance 5 MOhm)
Split core current transducer (impedance 200 kOhm)5 x
Measurement voltage 57…400 V AC 42...69 Hz between phase and neutral
100…690 V AC 42...69 Hz between phases
Frequency measurement range 20…450 Hz
Number of inputs 8 digital 30 V AC/60 V DC
Measurement accuracy Voltage +/- 0.1 %
Current +/- 0.1 %
Accuracy class Class 0.1S active energy IEC 62053-22
Class 0.1 active energy IEC 61557-12
Class 0.1 active energy ANSI C12.20
Class 0.5S reactive energy IEC 62053-24
Class 0.1 current IEC 61557-12
Class 0.1 voltage IEC 61557-12
Class 0.1 active power IEC 61557-12
Class 0.5 power factor IEC 61557-12
Number of Outputs 4 digital
2 form C relay output
Communication port protocol Modbus RTU 2400...115200 bps - 2-wire
ION 2400...115200 bps - 2-wire
DNP3 2400...115200 bps - 2-wire
Modbus TCP 10/100 Mbit/s
ION TCP 10/100 Mbit/s
DNP3 TCP 10/100 Mbit/s
IEC 61850
Ethernet Modbus TCP/IP daisy chain 10/100 Mbit/s
DHCP
DNS
DLMS
Communication port support 2 RS485 removable screw terminal block
Port Ethernet 10/100BASE-TX 2 RJ45
Communication gateway Ethernet/serial
Time synchronisation protocol GPS
IRIG-B
NTP
SNTP
PTP
Data recording Time stamping
Min/max of instantaneous values
User-definable data logs
Continuous logging or snapshot
Trending/forecasting
Event logs
Alarm logs
Configuration change
Power outage
User login/logout
Data logs
GPS synchronisation
Sequence of event recording
Memory capacity 2 GB
Cybersecurity Syslog protocol support
Robust security logs
Port hardening
Enable/disable communication ports
Hardware metrology lock
Web services Viewing of captured waveform
Web page
Pass/fail report for IEEE 519
Pass/fail report for EN 50160
ITIC (CBEMA) curve
SEMI curve
NEMA motor derating curve
Alarm notification by e-mail
TLS 1.2
Push historical data via mail
Ethernet service DHCP client
Device Profile Web Services (DPWS)
Rapid Scanning Tree Protocol (RSTP)
FTP/HTTP/HTTPS
Communication Service Compliant reports
Power quality summary
Energy report
EcoStruxure Power Events Analysis
SMTP e-mail notification
SNMP
Tamperproof of settings Protected by sealable cover
Mounting support DIN rail meter device
Door cut-out remote display
Electrical insulation class Class III EN/IEC 62052-11
Isolation voltage III400…690 V conforming to EN 61010-1:ed. 3
III347…600 V conforming to UL 61010-1:ed. 3
III347…600 V conforming to CSA C22.2 No 61010-1:ed. 3
Width 6.3 in (160 mm)
Depth 5.3 in (135.3 mm)
Height 6.3 in (160 mm)
Product Weight 3.3 lb(US) (1.5 kg)
Market Segment Data center
Healthcare
Semiconductor
Pharmaceutical
Chemical
Energy
Mining

All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.

If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.

In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.

PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.

Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.

PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.

Trusted By

"Fast service for obsolete parts"

Increasingly PLC/ HMI control platforms are becoming obsolete and parts are no longer supported, however PLC Direct had the HMI we needed and fast shipping for our system to get back online!

Buyer at GE Health

"Helping us move projects forward"

With supply chain issues increasingly affecting our business, PLC Direct has been there for us to supply the PLC products we need, when we need it. If they don't have it readily available, they find it and provide it quickly and reliably. This has helped us move forward with several projects that would have otherwise taken us many, many months to complete.

Buyer at E-Merge Systems – A Rockwell Integrator