LXM05AD14N4 Schneider

Main

Characteristic Value(s)
Range of product Lexium 05
Product or component type Motion servo drive
Component name LXM05A
Network number of phases Three phase
power supply voltage 380...480 V - 15...10 %
Continuous output current 5 A at 8 kHz
6 A at 4 kHz
Nominal power 1.4 kW at 4 kHz
Discrete input number 2 safety discrete input(s)
4 logic discrete input(s)
Analogue input number 2
Type of polarization Integrated and switchable impedances for CANopen
No polarization impedances for Modbus

Complementary

Characteristic Value(s)
power supply voltage limits 323…528 V
Supply frequency 50/60 Hz - 5...5 %
power supply frequency limits 47.5…63 Hz
transient RMS output current 10 A at 4 kHz for 3 s
7.5 A at 8 kHz for 3 s
Line current 3.3 A at 480 V
4.2 A at 380 V
maximum prospective line Isc 5 kA
Switching frequency 8 kHz
4 kHz
Overvoltage category III
Inrush current 60 A
Maximum leakage current 30 mA
Output voltage <= power supply voltage
Insulation Electrical between power and control
recommended type of cable for mounting in an enclosure Single-strand IEC cable (temperature: 45 °C) copper 70 °C PVC
Single-strand IEC cable (temperature: 45 °C) copper 90 °C XLPE/EPR
Electrical connection Terminal, clamping capacity: 6 mm², AWG 10 (PA/+, PBI, PBe)
Terminal, clamping capacity: 6 mm², AWG 10 (R/L1, S/L2, T/L3)
Tightening torque PA/+, PBI, PBe: 1.2 N.m
R/L1, S/L2, T/L3: 1.2 N.m
Discrete input type Logic (LI1, LI2, LI3, LI4 terminals)
Safety (PWRR_A, PWRR_B terminals)
Sampling duration ANA1+/ANA1-, ANA2+/ANA2-: 0.25 ms analog
LI1, LI2, LI3, LI4: 0.25 ms discrete
Discrete input voltage 24 V DC for logic
24 V DC for safety
Discrete input logic Negative (LI1, LI2, LI3, LI4) at State 0: > 19 V at State 1: < 9 V conforming to EN/IEC 61131-2 type 1
Positive logic (compliment of PWRR_A, compliment of PWRR_B) at State 0: < 5 V at State 1: > 15 V conforming to EN/IEC 61131-2 type 1
Positive logic (LI1, LI2, LI3, LI4) at State 0: < 5 V at State 1: > 15 V conforming to EN/IEC 61131-2 type 1
Response time <= 10 ms
Discrete output number 2
Discrete output type Logic output(s) (LO1, LO2)24 V DC
Discrete output voltage <= 30 V DC
Discrete output logic Negative (LO1, LO2) conforming to EN/IEC 61131-2
Positive (LO1, LO2) conforming to EN/IEC 61131-2
Contact bounce time 1 ms for LI1...LI4
Braking current 50 mA
Response time on output 1 ms (LO1, LO2) for discrete output(s)
Absolute accuracy error < +/- 1 % 25 °C
< +/- 2 % over operating temperature range
Linearity error < +/- 0.5 %
Analogue input type ANA1+/ANA1-, ANA2+/ANA2- analog input: differential +/- 10 V, impedance: >= 10000 Ohm, resolution: 14 bits
Protection type Inputs signal: against reverse polarity
Outputs signal: against short-circuits
Safety function PWR protection of the machine stop and/or prevent unintended operation of the servo motor conforming to IEC/EN 61800-5-2
PWR protection of the machine stop and/or prevent unintended operation of the servo motor conforming to ISO 13849-1 level d
PWR protection of the system process stop and/or prevent unintended operation of the servo motor conforming to EN/IEC 61508 level SIL2
PWR protection of the system process stop and/or prevent unintended operation of the servo motor conforming to IEC/EN 61800-5-2
Communication port protocol Modbus
CANopen
CANopen Motionbus
Connector type RJ45 (labelled CN4) for CANopen, CANopen Motionbus
RJ45 (labelled CN4) for Modbus
Spring terminals (labelled CN1) for CANopen, CANopen Motionbus
Method of access Slave CANopen, CANopen Motionbus
Physical interface 2-wire RS485 multidrop Modbus
RS422 for 1 A/B input(s), <= 400 kHz
RS422 for 1 CW/CCW input(s), <= 400 kHz
RS422 for 1 ESIM output input(s), <= 400 kHz
RS422 for 1 P/D input(s), <= 400 kHz
Transmission rate 50 kbps, 125 kbps, 250 kbps, 500 kbps, 1 Mbps for CANopen, CANopen Motionbus
9600, 19200, 38400 bps for Modbus
Data format 8 bits, no parity, 1 or 2 stop for Modbus
8 bits, odd or even parity, 1 stop for Modbus
Number of addresses 1…127 for CANopen, CANopen Motionbus
1…247 for Modbus
Communication service 1 receive SDO + 1 transmit SDO for CANopen Motionbus
2 PDO for CANopen Motionbus
2 receive SDO + 2 transmit SDO for CANopen
3 PDO + 1 configurable mapping PDO for CANopen
CiA DSP 402 profile for CANopen
CiA DSP 402 profile for CANopen Motionbus
Communication monitoring for Modbus
Diagnostics (08) for Modbus
Read device identification (43) for Modbus
Read holding registers (03) for Modbus
Read/write multiple registers (23) for Modbus
Write multiple registers (16) for Modbus
Write single register (06) for Modbus
diagnostics Drive voltage: 1 LED (red)
Error: 1 LED (CANopen)
RUN: 1 LED (CANopen)
Signalling function Display of faults integrated 7-segment display terminal
max nodes number 31 for Modbus
Input resistance 5 kOhm
Marking CE
type of cooling Fan
Operating position Vertical +/- 10 degree
Product weight 1.4 kg
Est. delivery between and    
Estimated delivery dates are estimates only. Int'l customers allow a few more days. For more precise delivery estimates, please contact us at support@plc-direct.com. Contact us in advance for expedited shipping options.
Sale price$2,894.95
1-year warranty
FREE WORDWIDE SHIPPING
Condition:
$0.00
$2,894.95
$841.90
Ach Direct Debit American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa

Main

Characteristic Value(s)
Range of product Lexium 05
Product or component type Motion servo drive
Component name LXM05A
Network number of phases Three phase
power supply voltage 380...480 V - 15...10 %
Continuous output current 5 A at 8 kHz
6 A at 4 kHz
Nominal power 1.4 kW at 4 kHz
Discrete input number 2 safety discrete input(s)
4 logic discrete input(s)
Analogue input number 2
Type of polarization Integrated and switchable impedances for CANopen
No polarization impedances for Modbus

Complementary

Characteristic Value(s)
power supply voltage limits 323…528 V
Supply frequency 50/60 Hz - 5...5 %
power supply frequency limits 47.5…63 Hz
transient RMS output current 10 A at 4 kHz for 3 s
7.5 A at 8 kHz for 3 s
Line current 3.3 A at 480 V
4.2 A at 380 V
maximum prospective line Isc 5 kA
Switching frequency 8 kHz
4 kHz
Overvoltage category III
Inrush current 60 A
Maximum leakage current 30 mA
Output voltage <= power supply voltage
Insulation Electrical between power and control
recommended type of cable for mounting in an enclosure Single-strand IEC cable (temperature: 45 °C) copper 70 °C PVC
Single-strand IEC cable (temperature: 45 °C) copper 90 °C XLPE/EPR
Electrical connection Terminal, clamping capacity: 6 mm², AWG 10 (PA/+, PBI, PBe)
Terminal, clamping capacity: 6 mm², AWG 10 (R/L1, S/L2, T/L3)
Tightening torque PA/+, PBI, PBe: 1.2 N.m
R/L1, S/L2, T/L3: 1.2 N.m
Discrete input type Logic (LI1, LI2, LI3, LI4 terminals)
Safety (PWRR_A, PWRR_B terminals)
Sampling duration ANA1+/ANA1-, ANA2+/ANA2-: 0.25 ms analog
LI1, LI2, LI3, LI4: 0.25 ms discrete
Discrete input voltage 24 V DC for logic
24 V DC for safety
Discrete input logic Negative (LI1, LI2, LI3, LI4) at State 0: > 19 V at State 1: < 9 V conforming to EN/IEC 61131-2 type 1
Positive logic (compliment of PWRR_A, compliment of PWRR_B) at State 0: < 5 V at State 1: > 15 V conforming to EN/IEC 61131-2 type 1
Positive logic (LI1, LI2, LI3, LI4) at State 0: < 5 V at State 1: > 15 V conforming to EN/IEC 61131-2 type 1
Response time <= 10 ms
Discrete output number 2
Discrete output type Logic output(s) (LO1, LO2)24 V DC
Discrete output voltage <= 30 V DC
Discrete output logic Negative (LO1, LO2) conforming to EN/IEC 61131-2
Positive (LO1, LO2) conforming to EN/IEC 61131-2
Contact bounce time 1 ms for LI1...LI4
Braking current 50 mA
Response time on output 1 ms (LO1, LO2) for discrete output(s)
Absolute accuracy error < +/- 1 % 25 °C
< +/- 2 % over operating temperature range
Linearity error < +/- 0.5 %
Analogue input type ANA1+/ANA1-, ANA2+/ANA2- analog input: differential +/- 10 V, impedance: >= 10000 Ohm, resolution: 14 bits
Protection type Inputs signal: against reverse polarity
Outputs signal: against short-circuits
Safety function PWR protection of the machine stop and/or prevent unintended operation of the servo motor conforming to IEC/EN 61800-5-2
PWR protection of the machine stop and/or prevent unintended operation of the servo motor conforming to ISO 13849-1 level d
PWR protection of the system process stop and/or prevent unintended operation of the servo motor conforming to EN/IEC 61508 level SIL2
PWR protection of the system process stop and/or prevent unintended operation of the servo motor conforming to IEC/EN 61800-5-2
Communication port protocol Modbus
CANopen
CANopen Motionbus
Connector type RJ45 (labelled CN4) for CANopen, CANopen Motionbus
RJ45 (labelled CN4) for Modbus
Spring terminals (labelled CN1) for CANopen, CANopen Motionbus
Method of access Slave CANopen, CANopen Motionbus
Physical interface 2-wire RS485 multidrop Modbus
RS422 for 1 A/B input(s), <= 400 kHz
RS422 for 1 CW/CCW input(s), <= 400 kHz
RS422 for 1 ESIM output input(s), <= 400 kHz
RS422 for 1 P/D input(s), <= 400 kHz
Transmission rate 50 kbps, 125 kbps, 250 kbps, 500 kbps, 1 Mbps for CANopen, CANopen Motionbus
9600, 19200, 38400 bps for Modbus
Data format 8 bits, no parity, 1 or 2 stop for Modbus
8 bits, odd or even parity, 1 stop for Modbus
Number of addresses 1…127 for CANopen, CANopen Motionbus
1…247 for Modbus
Communication service 1 receive SDO + 1 transmit SDO for CANopen Motionbus
2 PDO for CANopen Motionbus
2 receive SDO + 2 transmit SDO for CANopen
3 PDO + 1 configurable mapping PDO for CANopen
CiA DSP 402 profile for CANopen
CiA DSP 402 profile for CANopen Motionbus
Communication monitoring for Modbus
Diagnostics (08) for Modbus
Read device identification (43) for Modbus
Read holding registers (03) for Modbus
Read/write multiple registers (23) for Modbus
Write multiple registers (16) for Modbus
Write single register (06) for Modbus
diagnostics Drive voltage: 1 LED (red)
Error: 1 LED (CANopen)
RUN: 1 LED (CANopen)
Signalling function Display of faults integrated 7-segment display terminal
max nodes number 31 for Modbus
Input resistance 5 kOhm
Marking CE
type of cooling Fan
Operating position Vertical +/- 10 degree
Product weight 1.4 kg
Characteristic Value(s)
power supply voltage limits 323…528 V
Supply frequency 50/60 Hz - 5...5 %
power supply frequency limits 47.5…63 Hz
transient RMS output current 10 A at 4 kHz for 3 s
7.5 A at 8 kHz for 3 s
Line current 3.3 A at 480 V
4.2 A at 380 V
maximum prospective line Isc 5 kA
Switching frequency 8 kHz
4 kHz
Overvoltage category III
Inrush current 60 A
Maximum leakage current 30 mA
Output voltage <= power supply voltage
Insulation Electrical between power and control
recommended type of cable for mounting in an enclosure Single-strand IEC cable (temperature: 45 °C) copper 70 °C PVC
Single-strand IEC cable (temperature: 45 °C) copper 90 °C XLPE/EPR
Electrical connection Terminal, clamping capacity: 6 mm², AWG 10 (PA/+, PBI, PBe)
Terminal, clamping capacity: 6 mm², AWG 10 (R/L1, S/L2, T/L3)
Tightening torque PA/+, PBI, PBe: 1.2 N.m
R/L1, S/L2, T/L3: 1.2 N.m
Discrete input type Logic (LI1, LI2, LI3, LI4 terminals)
Safety (PWRR_A, PWRR_B terminals)
Sampling duration ANA1+/ANA1-, ANA2+/ANA2-: 0.25 ms analog
LI1, LI2, LI3, LI4: 0.25 ms discrete
Discrete input voltage 24 V DC for logic
24 V DC for safety
Discrete input logic Negative (LI1, LI2, LI3, LI4) at State 0: > 19 V at State 1: < 9 V conforming to EN/IEC 61131-2 type 1
Positive logic (compliment of PWRR_A, compliment of PWRR_B) at State 0: < 5 V at State 1: > 15 V conforming to EN/IEC 61131-2 type 1
Positive logic (LI1, LI2, LI3, LI4) at State 0: < 5 V at State 1: > 15 V conforming to EN/IEC 61131-2 type 1
Response time <= 10 ms
Discrete output number 2
Discrete output type Logic output(s) (LO1, LO2)24 V DC
Discrete output voltage <= 30 V DC
Discrete output logic Negative (LO1, LO2) conforming to EN/IEC 61131-2
Positive (LO1, LO2) conforming to EN/IEC 61131-2
Contact bounce time 1 ms for LI1...LI4
Braking current 50 mA
Response time on output 1 ms (LO1, LO2) for discrete output(s)
Absolute accuracy error < +/- 1 % 25 °C
< +/- 2 % over operating temperature range
Linearity error < +/- 0.5 %
Analogue input type ANA1+/ANA1-, ANA2+/ANA2- analog input: differential +/- 10 V, impedance: >= 10000 Ohm, resolution: 14 bits
Protection type Inputs signal: against reverse polarity
Outputs signal: against short-circuits
Safety function PWR protection of the machine stop and/or prevent unintended operation of the servo motor conforming to IEC/EN 61800-5-2
PWR protection of the machine stop and/or prevent unintended operation of the servo motor conforming to ISO 13849-1 level d
PWR protection of the system process stop and/or prevent unintended operation of the servo motor conforming to EN/IEC 61508 level SIL2
PWR protection of the system process stop and/or prevent unintended operation of the servo motor conforming to IEC/EN 61800-5-2
Communication port protocol Modbus
CANopen
CANopen Motionbus
Connector type RJ45 (labelled CN4) for CANopen, CANopen Motionbus
RJ45 (labelled CN4) for Modbus
Spring terminals (labelled CN1) for CANopen, CANopen Motionbus
Method of access Slave CANopen, CANopen Motionbus
Physical interface 2-wire RS485 multidrop Modbus
RS422 for 1 A/B input(s), <= 400 kHz
RS422 for 1 CW/CCW input(s), <= 400 kHz
RS422 for 1 ESIM output input(s), <= 400 kHz
RS422 for 1 P/D input(s), <= 400 kHz
Transmission rate 50 kbps, 125 kbps, 250 kbps, 500 kbps, 1 Mbps for CANopen, CANopen Motionbus
9600, 19200, 38400 bps for Modbus
Data format 8 bits, no parity, 1 or 2 stop for Modbus
8 bits, odd or even parity, 1 stop for Modbus
Number of addresses 1…127 for CANopen, CANopen Motionbus
1…247 for Modbus
Communication service 1 receive SDO + 1 transmit SDO for CANopen Motionbus
2 PDO for CANopen Motionbus
2 receive SDO + 2 transmit SDO for CANopen
3 PDO + 1 configurable mapping PDO for CANopen
CiA DSP 402 profile for CANopen
CiA DSP 402 profile for CANopen Motionbus
Communication monitoring for Modbus
Diagnostics (08) for Modbus
Read device identification (43) for Modbus
Read holding registers (03) for Modbus
Read/write multiple registers (23) for Modbus
Write multiple registers (16) for Modbus
Write single register (06) for Modbus
diagnostics Drive voltage: 1 LED (red)
Error: 1 LED (CANopen)
RUN: 1 LED (CANopen)
Signalling function Display of faults integrated 7-segment display terminal
max nodes number 31 for Modbus
Input resistance 5 kOhm
Marking CE
type of cooling Fan
Operating position Vertical +/- 10 degree
Product weight 1.4 kg

All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.

If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.

In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.

PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.

Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.

PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.

Trusted By

"Fast service for obsolete parts"

Increasingly PLC/ HMI control platforms are becoming obsolete and parts are no longer supported, however PLC Direct had the HMI we needed and fast shipping for our system to get back online!

Buyer at GE Health

"Helping us move projects forward"

With supply chain issues increasingly affecting our business, PLC Direct has been there for us to supply the PLC products we need, when we need it. If they don't have it readily available, they find it and provide it quickly and reliably. This has helped us move forward with several projects that would have otherwise taken us many, many months to complete.

Buyer at E-Merge Systems – A Rockwell Integrator