GV2-RT07 Schneider

TeSys GV motor circuit breaker, 3 poles (3P), 2.5A/690V, for high starting current peak motor applications 0.75kW@400V. It provides a thermal-magnetic protection with a thermal setting range 1.6-2.5A, a magnetic tripping level at 20xIn, high breaking capacity Icu 100kA@400V. Connection by screw clamp terminals. Start-stop control by toggle guaranteed for 100 000 cycles AC-3. It can be used for protection of 3-phase transformer applications. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine).

Main

Characteristic Value(s)
Range TeSys Deca
product name TeSys GV2
Product or Component Type Motor circuit breaker
Device short name GV2RT
Device Application Motor protection
Transformer
Trip unit technology Thermal-magnetic

Complementary

Characteristic Value(s)
Poles description 3P
Network type AC
Utilisation category Category A IEC 60947-2
AC-3 IEC 60947-4-1
AC-3e IEC 60947-4-1
Network frequency 50/60 Hz IEC 60947-2
Motor power kW 0.37 kW 220/230 V AC 50/60 Hz motor protection high peak current
0.75 kW 400/415 V AC 50/60 Hz motor protection high peak current
0.75 kW 440 V AC 50/60 Hz motor protection high peak current
1.1 kW 440 V AC 50/60 Hz motor protection high peak current
1.1 kW 500 V AC 50/60 Hz motor protection high peak current
1.5 kW 690 V AC 50/60 Hz motor protection high peak current
0.63 kW 230/240 V AC 50/60 Hz transformer protection
1 kW 400/415 V AC 50/60 Hz transformer protection
1.6 kW 500 V AC 50/60 Hz transformer protection
1.6 kW 690 V AC 50/60 Hz transformer protection
2 kW 690 V AC 50/60 Hz transformer protection
Breaking capacity 100 kA Icu 220/230 V AC 50/60 Hz IEC 60947-2
100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2
100 kA Icu 440 V AC 50/60 Hz IEC 60947-2
100 kA Icu 500 V AC 50/60 Hz IEC 60947-2
3 kA Icu 690 V AC 50/60 Hz IEC 60947-2
Control Type Toggle
Line Rated Current 2.5 A
Thermal protection adjustment range 1.6…2.5 A IEC 60947-2
Magnetic tripping current 51 A
[Ith] conventional free air thermal current 2.5 A IEC 60947-2
[Ue] rated operational voltage 690 V AC 50/60 Hz IEC 60947-2
[Ui] rated insulation voltage 690 V AC 50/60 Hz IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV IEC 60947-2
Suitability for isolation Yes IEC 60947-1
Power dissipation per pole 2.5 W
Mechanical durability 100000 cycles
Electrical durability 100000 cycles AC-3 415 V In
100000 cycles AC-3e 415 V In
Rated duty Uninterrupted IEC 60947-4-1
Connections - terminals Power circuit screw clamp terminal 2 0.002…0.009 in² (1…6 mm²)solid
Power circuit screw clamp terminal 2 0.002…0.009 in² (1.5…6 mm²)flexible without cable end
Power circuit screw clamp terminal 2 0.002…0.006 in² (1…4 mm²)flexible with cable end
Tightening torque 15.05 lbf.in (1.7 N.m) screw clamp terminal
Fixing mode 35 mm symmetrical DIN rail clipped
Panel screwed with adaptor plate)
Mounting position Horizontal
Vertical
Width 1.8 in (45 mm)
Height 3.5 in (89 mm)
Depth 3.09 in (78.5 mm)
Est. delivery between and    
Estimated delivery dates are estimates only. Int'l customers allow a few more days. For more precise delivery estimates, please contact us at support@plc-direct.com. Contact us in advance for expedited shipping options.
Sale price$116.78
1-year warranty
FREE WORDWIDE SHIPPING
Condition:
$116.78
$0.00
$0.00
Ach Direct Debit American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa

TeSys GV motor circuit breaker, 3 poles (3P), 2.5A/690V, for high starting current peak motor applications 0.75kW@400V. It provides a thermal-magnetic protection with a thermal setting range 1.6-2.5A, a magnetic tripping level at 20xIn, high breaking capacity Icu 100kA@400V. Connection by screw clamp terminals. Start-stop control by toggle guaranteed for 100 000 cycles AC-3. It can be used for protection of 3-phase transformer applications. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine).

Main

Characteristic Value(s)
Range TeSys Deca
product name TeSys GV2
Product or Component Type Motor circuit breaker
Device short name GV2RT
Device Application Motor protection
Transformer
Trip unit technology Thermal-magnetic

Complementary

Characteristic Value(s)
Poles description 3P
Network type AC
Utilisation category Category A IEC 60947-2
AC-3 IEC 60947-4-1
AC-3e IEC 60947-4-1
Network frequency 50/60 Hz IEC 60947-2
Motor power kW 0.37 kW 220/230 V AC 50/60 Hz motor protection high peak current
0.75 kW 400/415 V AC 50/60 Hz motor protection high peak current
0.75 kW 440 V AC 50/60 Hz motor protection high peak current
1.1 kW 440 V AC 50/60 Hz motor protection high peak current
1.1 kW 500 V AC 50/60 Hz motor protection high peak current
1.5 kW 690 V AC 50/60 Hz motor protection high peak current
0.63 kW 230/240 V AC 50/60 Hz transformer protection
1 kW 400/415 V AC 50/60 Hz transformer protection
1.6 kW 500 V AC 50/60 Hz transformer protection
1.6 kW 690 V AC 50/60 Hz transformer protection
2 kW 690 V AC 50/60 Hz transformer protection
Breaking capacity 100 kA Icu 220/230 V AC 50/60 Hz IEC 60947-2
100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2
100 kA Icu 440 V AC 50/60 Hz IEC 60947-2
100 kA Icu 500 V AC 50/60 Hz IEC 60947-2
3 kA Icu 690 V AC 50/60 Hz IEC 60947-2
Control Type Toggle
Line Rated Current 2.5 A
Thermal protection adjustment range 1.6…2.5 A IEC 60947-2
Magnetic tripping current 51 A
[Ith] conventional free air thermal current 2.5 A IEC 60947-2
[Ue] rated operational voltage 690 V AC 50/60 Hz IEC 60947-2
[Ui] rated insulation voltage 690 V AC 50/60 Hz IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV IEC 60947-2
Suitability for isolation Yes IEC 60947-1
Power dissipation per pole 2.5 W
Mechanical durability 100000 cycles
Electrical durability 100000 cycles AC-3 415 V In
100000 cycles AC-3e 415 V In
Rated duty Uninterrupted IEC 60947-4-1
Connections - terminals Power circuit screw clamp terminal 2 0.002…0.009 in² (1…6 mm²)solid
Power circuit screw clamp terminal 2 0.002…0.009 in² (1.5…6 mm²)flexible without cable end
Power circuit screw clamp terminal 2 0.002…0.006 in² (1…4 mm²)flexible with cable end
Tightening torque 15.05 lbf.in (1.7 N.m) screw clamp terminal
Fixing mode 35 mm symmetrical DIN rail clipped
Panel screwed with adaptor plate)
Mounting position Horizontal
Vertical
Width 1.8 in (45 mm)
Height 3.5 in (89 mm)
Depth 3.09 in (78.5 mm)
Characteristic Value(s)
Poles description 3P
Network type AC
Utilisation category Category A IEC 60947-2
AC-3 IEC 60947-4-1
AC-3e IEC 60947-4-1
Network frequency 50/60 Hz IEC 60947-2
Motor power kW 0.37 kW 220/230 V AC 50/60 Hz motor protection high peak current
0.75 kW 400/415 V AC 50/60 Hz motor protection high peak current
0.75 kW 440 V AC 50/60 Hz motor protection high peak current
1.1 kW 440 V AC 50/60 Hz motor protection high peak current
1.1 kW 500 V AC 50/60 Hz motor protection high peak current
1.5 kW 690 V AC 50/60 Hz motor protection high peak current
0.63 kW 230/240 V AC 50/60 Hz transformer protection
1 kW 400/415 V AC 50/60 Hz transformer protection
1.6 kW 500 V AC 50/60 Hz transformer protection
1.6 kW 690 V AC 50/60 Hz transformer protection
2 kW 690 V AC 50/60 Hz transformer protection
Breaking capacity 100 kA Icu 220/230 V AC 50/60 Hz IEC 60947-2
100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2
100 kA Icu 440 V AC 50/60 Hz IEC 60947-2
100 kA Icu 500 V AC 50/60 Hz IEC 60947-2
3 kA Icu 690 V AC 50/60 Hz IEC 60947-2
Control Type Toggle
Line Rated Current 2.5 A
Thermal protection adjustment range 1.6…2.5 A IEC 60947-2
Magnetic tripping current 51 A
[Ith] conventional free air thermal current 2.5 A IEC 60947-2
[Ue] rated operational voltage 690 V AC 50/60 Hz IEC 60947-2
[Ui] rated insulation voltage 690 V AC 50/60 Hz IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV IEC 60947-2
Suitability for isolation Yes IEC 60947-1
Power dissipation per pole 2.5 W
Mechanical durability 100000 cycles
Electrical durability 100000 cycles AC-3 415 V In
100000 cycles AC-3e 415 V In
Rated duty Uninterrupted IEC 60947-4-1
Connections - terminals Power circuit screw clamp terminal 2 0.002…0.009 in² (1…6 mm²)solid
Power circuit screw clamp terminal 2 0.002…0.009 in² (1.5…6 mm²)flexible without cable end
Power circuit screw clamp terminal 2 0.002…0.006 in² (1…4 mm²)flexible with cable end
Tightening torque 15.05 lbf.in (1.7 N.m) screw clamp terminal
Fixing mode 35 mm symmetrical DIN rail clipped
Panel screwed with adaptor plate)
Mounting position Horizontal
Vertical
Width 1.8 in (45 mm)
Height 3.5 in (89 mm)
Depth 3.09 in (78.5 mm)

All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.

If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.

In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.

PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.

Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.

PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.

Trusted By

"Fast service for obsolete parts"

Increasingly PLC/ HMI control platforms are becoming obsolete and parts are no longer supported, however PLC Direct had the HMI we needed and fast shipping for our system to get back online!

Buyer at GE Health

"Helping us move projects forward"

With supply chain issues increasingly affecting our business, PLC Direct has been there for us to supply the PLC products we need, when we need it. If they don't have it readily available, they find it and provide it quickly and reliably. This has helped us move forward with several projects that would have otherwise taken us many, many months to complete.

Buyer at E-Merge Systems – A Rockwell Integrator