1SDA101660R1 ABB - XT7S M 1250 Ekip Dip LSI In=1250A 4p F F

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 - 64.1 %

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:
SCIP:
10fac303-99c6-49c5-8e40-e5ce7a410c37 Italy
Simplified SCIP:
35fe6ab5-6d41-4109-b59a-33455a5235da Germany
467c08f7-e7e6-4dfe-adfc-0e6d5eb4648d Greece
3d107fec-0c50-4cb2-b39f-c5c679e7c572 Netherlands
f11fb4a6-c562-4574-a5df-4732cb2048bf Bulgaria
f9978f4a-9b43-4065-8321-9a69fe61c983 France
cfdc050e-c5b8-44de-8e42-42425359452c Belgium
801c4228-d642-4511-b426-e7302f552d4e Spain
74601f4f-fb05-4b1e-aa6f-d600d5ef1b59 Hungary
fdcc3d54-7f1b-42fc-831f-77d139641ca4 Poland
85924424-4aab-445e-8a28-ca855368e41c Czech Republic
8b7eb43f-70bb-4114-8193-4386a47aef33 Poland
e9e0cf70-ec23-4a66-a7f1-44aa7a7f77d8 Sweden
806b3221-ca83-4261-b0b9-d45d57670fd1 Belgium
689f66ae-92e4-4eb5-8fe1-c0b2e0e7ac65 Germany
b5b94316-106e-4c94-a46c-30fdcc59e321 Finland
99fb851f-ca48-4103-8e40-e88635d3e62d France
71e4c891-cd1f-456c-951b-587a96890647 Norway
1e01b3ce-15d1-4c51-b8f1-e33821a2fbca Hungary
3ce401cf-fe9f-4678-9fd7-a5cd56338357 Poland
f78de715-343b-46ca-93af-cd03011da693 Denmark
d1dea2d5-cb9f-44f0-a648-dca4d6db2ec3 Germany
e529d14a-436a-4baa-a96d-9244da04cf28 Estonia
5758dd9c-f2d1-4389-9d7c-b1e7a8169b4a Germany
20fd9fa1-8fd9-4cdd-8281-5e03194b1688 Germany
7be1d6b3-bbd2-4fab-88f0-af63830d2cfd Sweden
d35ee7a7-3040-4d25-8e17-b8ef79ea3fe5 Croatia
84ad3e36-244d-4546-8d47-798625136cbb Portugal
35fe6ab5-6d41-4109-b59a-33455a5235da Germany
467c08f7-e7e6-4dfe-adfc-0e6d5eb4648d Greece
3d107fec-0c50-4cb2-b39f-c5c679e7c572 Netherlands
f11fb4a6-c562-4574-a5df-4732cb2048bf Bulgaria
f9978f4a-9b43-4065-8321-9a69fe61c983 France
cfdc050e-c5b8-44de-8e42-42425359452c Belgium
801c4228-d642-4511-b426-e7302f552d4e Spain
74601f4f-fb05-4b1e-aa6f-d600d5ef1b59 Hungary
fdcc3d54-7f1b-42fc-831f-77d139641ca4 Poland
85924424-4aab-445e-8a28-ca855368e41c Czech Republic

Environmental

Ambient Air Temperature:
Operation -40 ... 125 °C
Environmental Information:

Ordering

Order Code US and Canada:
XSEKCFAZZAAAA00000
E-Number (Norway):
4380891
EAN:
8056221017046
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
280 mm
Product Net Height:
268 mm
Product Net Depth / Length:
178 mm
Product Net Weight:
14 kg

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
360 mm
Package Level 1 Height:
350 mm
Package Level 1 Depth / Length:
360 mm
Package Level 1 Gross Weight:
15.5 kg
Package Level 1 EAN:
8056221017046

Additional Information

Circuit Breaker Type to be Associated:
Power Distribution
Product Main Type:
SACE Tmax XT
Product Name:
Moulded Case Circuit Breaker
Product Type:
Automatic Circuit Breaker
Version:
F
CAD Dimensional Drawing:

Technical

Current Type:
AC
Electrical Durability:
3000 cycle
60 cycles per hour
3000 cycle
60 cycles per hour
Mechanical Durability:
20000 cycle
60 cycles per hour
20000 cycle
60 cycles per hour
Number of Poles:
4P
Order Multiple:
1 piece
Power Loss:
at Rated Operating Conditions per Pole 57 W
Rated Current (In):
1250 A
Rated Impulse Withstand Voltage (Uimp):
8 kV
Rated Insulation Voltage (Ui):
1000 V
Rated Operational Voltage:
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 85 kA
(230 V AC) 85 kA
(240 V AC) 85 kA
(380 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 45 kA
(525 V AC) 45 kA
(690 V AC) 30 kA
(220 V AC) 85 kA
(230 V AC) 85 kA
(240 V AC) 85 kA
(380 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 45 kA
(525 V AC) 45 kA
(690 V AC) 30 kA
Rated Short-time Withstand Current Low Voltage (Icw):
20 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(220 V AC) 85 kA
(230 V AC) 85 kA
(240 V AC) 85 kA
(380 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 45 kA
(525 V AC) 45 kA
(690 V AC) 30 kA
(220 V AC) 85 kA
(230 V AC) 85 kA
(240 V AC) 85 kA
(380 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 45 kA
(525 V AC) 45 kA
(690 V AC) 30 kA
Rated Uninterrupted Current (Iu):
1250 A
Release:
Ekip Dip LSI
Release Type:
EL
Short-Circuit Performance Level:
S
Standards:
IEC60947-2
Sub-type:
XT7M
Terminal Connection Type:
Front

External Classifications and Standards

ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409
Price on request
Ask for quote
   

Notify Me When Available

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 - 64.1 %

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:
SCIP:
10fac303-99c6-49c5-8e40-e5ce7a410c37 Italy
Simplified SCIP:
35fe6ab5-6d41-4109-b59a-33455a5235da Germany
467c08f7-e7e6-4dfe-adfc-0e6d5eb4648d Greece
3d107fec-0c50-4cb2-b39f-c5c679e7c572 Netherlands
f11fb4a6-c562-4574-a5df-4732cb2048bf Bulgaria
f9978f4a-9b43-4065-8321-9a69fe61c983 France
cfdc050e-c5b8-44de-8e42-42425359452c Belgium
801c4228-d642-4511-b426-e7302f552d4e Spain
74601f4f-fb05-4b1e-aa6f-d600d5ef1b59 Hungary
fdcc3d54-7f1b-42fc-831f-77d139641ca4 Poland
85924424-4aab-445e-8a28-ca855368e41c Czech Republic
8b7eb43f-70bb-4114-8193-4386a47aef33 Poland
e9e0cf70-ec23-4a66-a7f1-44aa7a7f77d8 Sweden
806b3221-ca83-4261-b0b9-d45d57670fd1 Belgium
689f66ae-92e4-4eb5-8fe1-c0b2e0e7ac65 Germany
b5b94316-106e-4c94-a46c-30fdcc59e321 Finland
99fb851f-ca48-4103-8e40-e88635d3e62d France
71e4c891-cd1f-456c-951b-587a96890647 Norway
1e01b3ce-15d1-4c51-b8f1-e33821a2fbca Hungary
3ce401cf-fe9f-4678-9fd7-a5cd56338357 Poland
f78de715-343b-46ca-93af-cd03011da693 Denmark
d1dea2d5-cb9f-44f0-a648-dca4d6db2ec3 Germany
e529d14a-436a-4baa-a96d-9244da04cf28 Estonia
5758dd9c-f2d1-4389-9d7c-b1e7a8169b4a Germany
20fd9fa1-8fd9-4cdd-8281-5e03194b1688 Germany
7be1d6b3-bbd2-4fab-88f0-af63830d2cfd Sweden
d35ee7a7-3040-4d25-8e17-b8ef79ea3fe5 Croatia
84ad3e36-244d-4546-8d47-798625136cbb Portugal
35fe6ab5-6d41-4109-b59a-33455a5235da Germany
467c08f7-e7e6-4dfe-adfc-0e6d5eb4648d Greece
3d107fec-0c50-4cb2-b39f-c5c679e7c572 Netherlands
f11fb4a6-c562-4574-a5df-4732cb2048bf Bulgaria
f9978f4a-9b43-4065-8321-9a69fe61c983 France
cfdc050e-c5b8-44de-8e42-42425359452c Belgium
801c4228-d642-4511-b426-e7302f552d4e Spain
74601f4f-fb05-4b1e-aa6f-d600d5ef1b59 Hungary
fdcc3d54-7f1b-42fc-831f-77d139641ca4 Poland
85924424-4aab-445e-8a28-ca855368e41c Czech Republic

Environmental

Ambient Air Temperature:
Operation -40 ... 125 °C
Environmental Information:

Ordering

Order Code US and Canada:
XSEKCFAZZAAAA00000
E-Number (Norway):
4380891
EAN:
8056221017046
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
280 mm
Product Net Height:
268 mm
Product Net Depth / Length:
178 mm
Product Net Weight:
14 kg

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
360 mm
Package Level 1 Height:
350 mm
Package Level 1 Depth / Length:
360 mm
Package Level 1 Gross Weight:
15.5 kg
Package Level 1 EAN:
8056221017046

Additional Information

Circuit Breaker Type to be Associated:
Power Distribution
Product Main Type:
SACE Tmax XT
Product Name:
Moulded Case Circuit Breaker
Product Type:
Automatic Circuit Breaker
Version:
F
CAD Dimensional Drawing:

Technical

Current Type:
AC
Electrical Durability:
3000 cycle
60 cycles per hour
3000 cycle
60 cycles per hour
Mechanical Durability:
20000 cycle
60 cycles per hour
20000 cycle
60 cycles per hour
Number of Poles:
4P
Order Multiple:
1 piece
Power Loss:
at Rated Operating Conditions per Pole 57 W
Rated Current (In):
1250 A
Rated Impulse Withstand Voltage (Uimp):
8 kV
Rated Insulation Voltage (Ui):
1000 V
Rated Operational Voltage:
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 85 kA
(230 V AC) 85 kA
(240 V AC) 85 kA
(380 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 45 kA
(525 V AC) 45 kA
(690 V AC) 30 kA
(220 V AC) 85 kA
(230 V AC) 85 kA
(240 V AC) 85 kA
(380 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 45 kA
(525 V AC) 45 kA
(690 V AC) 30 kA
Rated Short-time Withstand Current Low Voltage (Icw):
20 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(220 V AC) 85 kA
(230 V AC) 85 kA
(240 V AC) 85 kA
(380 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 45 kA
(525 V AC) 45 kA
(690 V AC) 30 kA
(220 V AC) 85 kA
(230 V AC) 85 kA
(240 V AC) 85 kA
(380 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 45 kA
(525 V AC) 45 kA
(690 V AC) 30 kA
Rated Uninterrupted Current (Iu):
1250 A
Release:
Ekip Dip LSI
Release Type:
EL
Short-Circuit Performance Level:
S
Standards:
IEC60947-2
Sub-type:
XT7M
Terminal Connection Type:
Front

External Classifications and Standards

ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409
ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409

All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.

If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.

In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.

PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.

Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.

PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.

Trusted By

"Fast service for obsolete parts"

Increasingly PLC/ HMI control platforms are becoming obsolete and parts are no longer supported, however PLC Direct had the HMI we needed and fast shipping for our system to get back online!

Buyer at GE Health

"Helping us move projects forward"

With supply chain issues increasingly affecting our business, PLC Direct has been there for us to supply the PLC products we need, when we need it. If they don't have it readily available, they find it and provide it quickly and reliably. This has helped us move forward with several projects that would have otherwise taken us many, many months to complete.

Buyer at E-Merge Systems – A Rockwell Integrator