1SDA066801R1 ABB

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 - 55.9 %

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:
SCIP:
8acd1baa-b059-4d51-abdc-ea46defeb35e Italy
Simplified SCIP:
d1aaf08d-e25f-4668-a057-4628057c8769 Germany
a3cb6bff-8410-4229-8646-6cccfa9434c2 Poland
9ff0f6b4-a69c-43a0-ba19-92bc124a3464 Norway
2b859db5-b8d7-4582-9f9e-a714dfb57603 Finland
2c089ba4-fd3a-4e3d-b3da-8607a803d823 Netherlands
d265c6de-5560-448d-be55-8b6e38c8e47e Germany
e0d795ac-e812-48bb-93ae-39c2b1fe2aa8 Denmark
b9b12f17-54ef-40cc-8b89-a4e1a85e6f16 Germany
c6298b97-9d9e-42ed-b595-bc5572008f7f Croatia
49905c59-d051-4933-aee8-957313e7c76b France
49a55cdf-4a0f-48db-a710-1f0b682d75da Sweden
ba601371-442d-4856-91e4-aed91c4397a6 Germany
96e8b14b-e8c2-4ff3-b457-9d321b80a48c Germany
f834e079-b952-4094-819d-77fa6c5c2e9f France
ef2515cc-3f80-4037-9726-465563cd6237 Netherlands
755304cd-f665-4b13-9cf6-10f93e474874 Spain
efe35e1a-4e77-4211-bebc-18b4ca05a992 Estonia
c6675afb-be78-4a8f-9a37-e2fbbce32849 Greece
f105555f-afc7-4bfc-8428-6db856df2c98 Portugal
243cc790-2e64-4328-97df-dd54d53fbcd3 Bulgaria
f8571fb3-a76a-45f5-b32b-a8fb8bc01539 Sweden
0f189183-bc01-4cac-acea-7637fb6a169a Poland
dbf95c07-c982-4c67-8a65-b5087833b881 Netherlands
f099941a-3638-4e46-bc58-30dd8b7335ab Czech Republic
29ca709b-7996-405d-bd6d-5d766c178307 Poland
8a2dc3a6-691e-442a-b562-b5f3081e360d Netherlands
ed75ce49-731b-4a2c-a2aa-48b67198a8ec Netherlands
d1aaf08d-e25f-4668-a057-4628057c8769 Germany
a3cb6bff-8410-4229-8646-6cccfa9434c2 Poland
9ff0f6b4-a69c-43a0-ba19-92bc124a3464 Norway
2b859db5-b8d7-4582-9f9e-a714dfb57603 Finland
2c089ba4-fd3a-4e3d-b3da-8607a803d823 Netherlands
d265c6de-5560-448d-be55-8b6e38c8e47e Germany
e0d795ac-e812-48bb-93ae-39c2b1fe2aa8 Denmark
b9b12f17-54ef-40cc-8b89-a4e1a85e6f16 Germany
c6298b97-9d9e-42ed-b595-bc5572008f7f Croatia
49905c59-d051-4933-aee8-957313e7c76b France

Environmental

Environmental Information:

Ordering

Order Code US and Canada:
XT1BE3025AFF000XXX
E-Number (Finland):
3640497
E-Number (Norway):
4309602
EAN:
8015644003289
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
76.2 mm
Product Net Height:
130 mm
Product Net Depth / Length:
70 mm
Product Net Weight:
1.1 kg

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
128 mm
Package Level 1 Height:
135 mm
Package Level 1 Depth / Length:
143 mm
Package Level 1 Gross Weight:
1.126 kg
Package Level 1 EAN:
8015644003289

Additional Information

Circuit Breaker Type to be Associated:
Power Distribution
Product Main Type:
SACE Tmax XT
Product Name:
Moulded Case Circuit Breaker
Product Type:
Automatic Circuit Breaker
Version:
F
CAD Dimensional Drawing:

Technical

Connecting Capacity Main Circuit:
Busbar 45.5 ... 80 mm²
Current Type:
AC/DC
Electrical Durability:
120 cycles per hour
8000 cycle
120 cycles per hour
8000 cycle
Mechanical Durability:
240 cycles per hour
25000 cycle
240 cycles per hour
25000 cycle
Number of Poles:
3P
Opening Time:
CB with SOR 30 ms
CB with UVR 30 ms
CB with SOR 30 ms
CB with UVR 30 ms
Order Multiple:
1 piece
Power Loss:
at Rated Operating Conditions per Pole 2 W
Rated Current (In):
25 A
Rated Frequency (f):
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp):
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii):
450 A
Rated Insulation Voltage (Ui):
800 V
Rated Operational Voltage:
690 V AC
500 V DC
690 V AC
500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 25 kA
(230 V AC) 25 kA
(240 V AC) 25 kA
(380 V AC) 18 kA
(415 V AC) 18 kA
(440 V AC) 11.25 kA
(500 V AC) 8 kA
(525 V AC) 6 kA
(690 V AC) 3 kA
(250 V DC) 2 Poles in Series 18 kA
(500 V DC) 3 Poles in Series 18 kA
(220 V AC) 25 kA
(230 V AC) 25 kA
(240 V AC) 25 kA
(380 V AC) 18 kA
(415 V AC) 18 kA
(440 V AC) 11.25 kA
(500 V AC) 8 kA
(525 V AC) 6 kA
(690 V AC) 3 kA
(250 V DC) 2 Poles in Series 18 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(220 V AC) 25 kA
(230 V AC) 25 kA
(240 V AC) 25 kA
(380 V AC) 18 kA
(415 V AC) 18 kA
(440 V AC) 15 kA
(500 V AC) 8 kA
(525 V AC) 6 kA
(690 V AC) 3 kA
(250 V DC) 2 Poles in Series 18 kA
(500 V DC) 3 Poles in Series 18 kA
(220 V AC) 25 kA
(230 V AC) 25 kA
(240 V AC) 25 kA
(380 V AC) 18 kA
(415 V AC) 18 kA
(440 V AC) 15 kA
(500 V AC) 8 kA
(525 V AC) 6 kA
(690 V AC) 3 kA
(250 V DC) 2 Poles in Series 18 kA
Rated Uninterrupted Current (Iu):
160 A
Rated Voltage (Ur):
690 V
Recommended Screw Driver:
Main Circuit M6
Release:
TMD
Release Type:
TM
Setting Range:
17.5...25 A
Short-Circuit Performance Level:
B
Standards:
IEC60947-2
Sub-type:
XT1
Terminal Connection Type:
Front
Terminal Type:
Bolt
Tightening Torque:
6 N·m

Certificates and Declarations

ATEX Certificate:
Declaration of Conformity - CE:
GL Certificate:
LR Certificate:
UL Certificate:
VDE Certificate:
Dimension Diagram:
Mechanical Drawings:
Instructions and Manuals:

External Classifications and Standards

ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409
Est. delivery between and    
Estimated delivery dates are estimates only. Int'l customers allow a few more days. For more precise delivery estimates, please contact us at support@plc-direct.com. Contact us in advance for expedited shipping options.
Sale price$136.17
1-year warranty
FREE WORDWIDE SHIPPING
Condition:
$136.17
$0.00
$0.00
Ach Direct Debit American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 - 55.9 %

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:
SCIP:
8acd1baa-b059-4d51-abdc-ea46defeb35e Italy
Simplified SCIP:
d1aaf08d-e25f-4668-a057-4628057c8769 Germany
a3cb6bff-8410-4229-8646-6cccfa9434c2 Poland
9ff0f6b4-a69c-43a0-ba19-92bc124a3464 Norway
2b859db5-b8d7-4582-9f9e-a714dfb57603 Finland
2c089ba4-fd3a-4e3d-b3da-8607a803d823 Netherlands
d265c6de-5560-448d-be55-8b6e38c8e47e Germany
e0d795ac-e812-48bb-93ae-39c2b1fe2aa8 Denmark
b9b12f17-54ef-40cc-8b89-a4e1a85e6f16 Germany
c6298b97-9d9e-42ed-b595-bc5572008f7f Croatia
49905c59-d051-4933-aee8-957313e7c76b France
49a55cdf-4a0f-48db-a710-1f0b682d75da Sweden
ba601371-442d-4856-91e4-aed91c4397a6 Germany
96e8b14b-e8c2-4ff3-b457-9d321b80a48c Germany
f834e079-b952-4094-819d-77fa6c5c2e9f France
ef2515cc-3f80-4037-9726-465563cd6237 Netherlands
755304cd-f665-4b13-9cf6-10f93e474874 Spain
efe35e1a-4e77-4211-bebc-18b4ca05a992 Estonia
c6675afb-be78-4a8f-9a37-e2fbbce32849 Greece
f105555f-afc7-4bfc-8428-6db856df2c98 Portugal
243cc790-2e64-4328-97df-dd54d53fbcd3 Bulgaria
f8571fb3-a76a-45f5-b32b-a8fb8bc01539 Sweden
0f189183-bc01-4cac-acea-7637fb6a169a Poland
dbf95c07-c982-4c67-8a65-b5087833b881 Netherlands
f099941a-3638-4e46-bc58-30dd8b7335ab Czech Republic
29ca709b-7996-405d-bd6d-5d766c178307 Poland
8a2dc3a6-691e-442a-b562-b5f3081e360d Netherlands
ed75ce49-731b-4a2c-a2aa-48b67198a8ec Netherlands
d1aaf08d-e25f-4668-a057-4628057c8769 Germany
a3cb6bff-8410-4229-8646-6cccfa9434c2 Poland
9ff0f6b4-a69c-43a0-ba19-92bc124a3464 Norway
2b859db5-b8d7-4582-9f9e-a714dfb57603 Finland
2c089ba4-fd3a-4e3d-b3da-8607a803d823 Netherlands
d265c6de-5560-448d-be55-8b6e38c8e47e Germany
e0d795ac-e812-48bb-93ae-39c2b1fe2aa8 Denmark
b9b12f17-54ef-40cc-8b89-a4e1a85e6f16 Germany
c6298b97-9d9e-42ed-b595-bc5572008f7f Croatia
49905c59-d051-4933-aee8-957313e7c76b France

Environmental

Environmental Information:

Ordering

Order Code US and Canada:
XT1BE3025AFF000XXX
E-Number (Finland):
3640497
E-Number (Norway):
4309602
EAN:
8015644003289
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
76.2 mm
Product Net Height:
130 mm
Product Net Depth / Length:
70 mm
Product Net Weight:
1.1 kg

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
128 mm
Package Level 1 Height:
135 mm
Package Level 1 Depth / Length:
143 mm
Package Level 1 Gross Weight:
1.126 kg
Package Level 1 EAN:
8015644003289

Additional Information

Circuit Breaker Type to be Associated:
Power Distribution
Product Main Type:
SACE Tmax XT
Product Name:
Moulded Case Circuit Breaker
Product Type:
Automatic Circuit Breaker
Version:
F
CAD Dimensional Drawing:

Technical

Connecting Capacity Main Circuit:
Busbar 45.5 ... 80 mm²
Current Type:
AC/DC
Electrical Durability:
120 cycles per hour
8000 cycle
120 cycles per hour
8000 cycle
Mechanical Durability:
240 cycles per hour
25000 cycle
240 cycles per hour
25000 cycle
Number of Poles:
3P
Opening Time:
CB with SOR 30 ms
CB with UVR 30 ms
CB with SOR 30 ms
CB with UVR 30 ms
Order Multiple:
1 piece
Power Loss:
at Rated Operating Conditions per Pole 2 W
Rated Current (In):
25 A
Rated Frequency (f):
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp):
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii):
450 A
Rated Insulation Voltage (Ui):
800 V
Rated Operational Voltage:
690 V AC
500 V DC
690 V AC
500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 25 kA
(230 V AC) 25 kA
(240 V AC) 25 kA
(380 V AC) 18 kA
(415 V AC) 18 kA
(440 V AC) 11.25 kA
(500 V AC) 8 kA
(525 V AC) 6 kA
(690 V AC) 3 kA
(250 V DC) 2 Poles in Series 18 kA
(500 V DC) 3 Poles in Series 18 kA
(220 V AC) 25 kA
(230 V AC) 25 kA
(240 V AC) 25 kA
(380 V AC) 18 kA
(415 V AC) 18 kA
(440 V AC) 11.25 kA
(500 V AC) 8 kA
(525 V AC) 6 kA
(690 V AC) 3 kA
(250 V DC) 2 Poles in Series 18 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(220 V AC) 25 kA
(230 V AC) 25 kA
(240 V AC) 25 kA
(380 V AC) 18 kA
(415 V AC) 18 kA
(440 V AC) 15 kA
(500 V AC) 8 kA
(525 V AC) 6 kA
(690 V AC) 3 kA
(250 V DC) 2 Poles in Series 18 kA
(500 V DC) 3 Poles in Series 18 kA
(220 V AC) 25 kA
(230 V AC) 25 kA
(240 V AC) 25 kA
(380 V AC) 18 kA
(415 V AC) 18 kA
(440 V AC) 15 kA
(500 V AC) 8 kA
(525 V AC) 6 kA
(690 V AC) 3 kA
(250 V DC) 2 Poles in Series 18 kA
Rated Uninterrupted Current (Iu):
160 A
Rated Voltage (Ur):
690 V
Recommended Screw Driver:
Main Circuit M6
Release:
TMD
Release Type:
TM
Setting Range:
17.5...25 A
Short-Circuit Performance Level:
B
Standards:
IEC60947-2
Sub-type:
XT1
Terminal Connection Type:
Front
Terminal Type:
Bolt
Tightening Torque:
6 N·m

Certificates and Declarations

ATEX Certificate:
Declaration of Conformity - CE:
GL Certificate:
LR Certificate:
UL Certificate:
VDE Certificate:
Dimension Diagram:
Mechanical Drawings:
Instructions and Manuals:

External Classifications and Standards

ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409
ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409

All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.

If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.

In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.

PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.

Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.

PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.

Trusted By

"Fast service for obsolete parts"

Increasingly PLC/ HMI control platforms are becoming obsolete and parts are no longer supported, however PLC Direct had the HMI we needed and fast shipping for our system to get back online!

Buyer at GE Health

"Helping us move projects forward"

With supply chain issues increasingly affecting our business, PLC Direct has been there for us to supply the PLC products we need, when we need it. If they don't have it readily available, they find it and provide it quickly and reliably. This has helped us move forward with several projects that would have otherwise taken us many, many months to complete.

Buyer at E-Merge Systems – A Rockwell Integrator