1SBL357010R7211 ABB - AF50-30-11RT-72

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
8536490065

Dimensions

Product Net Width:
70 mm
Product Net Depth / Length:
108 mm
Product Net Height:
110 mm
Product Net Weight:
1.23 kg

Technical

Number of Main Contacts NO:
3
Number of Main Contacts NC:
0
Number of Auxiliary Contacts NO:
1
Number of Auxiliary Contacts NC:
1
Number of Poles:
3P
Standards:
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 508, CSA C22.2 No. 14, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011 (on request), IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives.
Rated Operational Voltage:
Auxiliary Circuit 690 V
Main Circuit 690 V
Auxiliary Circuit 690 V
Main Circuit 690 V
Rated Operational Current AC-1 (Ie):
(690 V) 40 °C 100 A
(690 V) 55 °C 85 A
(690 V) 70 °C 70 A
(690 V) 40 °C 100 A
(690 V) 55 °C 85 A
(690 V) 70 °C 70 A
Rated Operational Current AC-3 (Ie):
(415 V) 55 °C 50 A
(440 V) 55 °C 45 A
(500 V) 55 °C 45 A
(690 V) 55 °C 35 A
(380 / 400 V) 55 °C 50 A
(220 / 230 / 240 V) 55 °C 53 A
(415 V) 55 °C 50 A
(440 V) 55 °C 45 A
(500 V) 55 °C 45 A
(690 V) 55 °C 35 A
(380 / 400 V) 55 °C 50 A
(220 / 230 / 240 V) 55 °C 53 A
Rated Operational Current AC-15 (Ie):
(24 / 127 V) 6 A
(220 / 240 V) 4 A
(24 / 127 V) 6 A
(220 / 240 V) 4 A
Rated Operational Current DC-1 (Ie):
(110 V) 2 Poles in Series, 40 °C 100 A
(110 V) 2 Poles in Series, 55 °C 85 A
(110 V) 2 Poles in Series, 70 °C 70 A
(110 V) 3 Poles in Series, 40 °C 100 A
(110 V) 3 Poles in Series, 55 °C 85 A
(110 V) 3 Poles in Series, 70 °C 70 A
(220 V) 3 Poles in Series, 40 °C 100 A
(220 V) 3 Poles in Series, 55 °C 85 A
(220 V) 3 Poles in Series, 70 °C 70 A
(72 V) 1-Pole, 40 °C 100 A
(72 V) 1-Pole, 55 °C 85 A
(72 V) 1-Pole, 70 °C 70 A
(72 V) 2 Poles in Series, 40 °C 100 A
(72 V) 2 Poles in Series, 55 °C 85 A
(72 V) 2 Poles in Series, 70 °C 70 A
(72 V) 3 Poles in Series, 40 °C 100 A
(72 V) 3 Poles in Series, 55 °C 85 A
(72 V) 3 Poles in Series, 70 °C 70 A
(110 V) 2 Poles in Series, 40 °C 100 A
(110 V) 2 Poles in Series, 55 °C 85 A
(110 V) 2 Poles in Series, 70 °C 70 A
(110 V) 3 Poles in Series, 40 °C 100 A
(110 V) 3 Poles in Series, 55 °C 85 A
(110 V) 3 Poles in Series, 70 °C 70 A
(220 V) 3 Poles in Series, 40 °C 100 A
(220 V) 3 Poles in Series, 55 °C 85 A
(220 V) 3 Poles in Series, 70 °C 70 A
(72 V) 1-Pole, 40 °C 100 A
Rated Operational Current DC-3 (Ie):
(110 V) 2 Poles in Series, 40 °C 100 A
(110 V) 2 Poles in Series, 55 °C 85 A
(110 V) 2 Poles in Series, 70 °C 70 A
(110 V) 3 Poles in Series, 40 °C 100 A
(110 V) 3 Poles in Series, 55 °C 85 A
(110 V) 3 Poles in Series, 70 °C 70 A
(220 V) 3 Poles in Series, 40 °C 100 A
(220 V) 3 Poles in Series, 55 °C 85 A
(220 V) 3 Poles in Series, 70 °C 70 A
(72 V) 1-Pole, 40 °C 100 A
(72 V) 1-Pole, 55 °C 85 A
(72 V) 1-Pole, 70 °C 70 A
(72 V) 2 Poles in Series, 40 °C 100 A
(72 V) 2 Poles in Series, 55 °C 85 A
(72 V) 2 Poles in Series, 70 °C 70 A
(72 V) 3 Poles in Series, 40 °C 100 A
(72 V) 3 Poles in Series, 55 °C 85 A
(72 V) 3 Poles in Series, 70 °C 70 A
(110 V) 2 Poles in Series, 40 °C 100 A
(110 V) 2 Poles in Series, 55 °C 85 A
(110 V) 2 Poles in Series, 70 °C 70 A
(110 V) 3 Poles in Series, 40 °C 100 A
(110 V) 3 Poles in Series, 55 °C 85 A
(110 V) 3 Poles in Series, 70 °C 70 A
(220 V) 3 Poles in Series, 40 °C 100 A
(220 V) 3 Poles in Series, 55 °C 85 A
(220 V) 3 Poles in Series, 70 °C 70 A
(72 V) 1-Pole, 40 °C 100 A
Rated Operational Current DC-5 (Ie):
(110 V) 2 Poles in Series, 40 °C 80 A
(110 V) 2 Poles in Series, 55 °C 80 A
(110 V) 2 Poles in Series, 70 °C 70 A
(110 V) 3 Poles in Series, 40 °C 100 A
(110 V) 3 Poles in Series, 55 °C 85 A
(110 V) 3 Poles in Series, 70 °C 70 A
(220 V) 3 Poles in Series, 40 °C 50 A
(220 V) 3 Poles in Series, 55 °C 50 A
(220 V) 3 Poles in Series, 70 °C 50 A
(72 V) 1-Pole, 40 °C 50 A
(72 V) 1-Pole, 55 °C 50 A
(72 V) 1-Pole, 70 °C 50 A
(72 V) 2 Poles in Series, 40 °C 100 A
(72 V) 2 Poles in Series, 55 °C 85 A
(72 V) 2 Poles in Series, 70 °C 70 A
(72 V) 3 Poles in Series, 40 °C 100 A
(72 V) 3 Poles in Series, 55 °C 85 A
(72 V) 3 Poles in Series, 70 °C 70 A
(110 V) 2 Poles in Series, 40 °C 80 A
(110 V) 2 Poles in Series, 55 °C 80 A
(110 V) 2 Poles in Series, 70 °C 70 A
(110 V) 3 Poles in Series, 40 °C 100 A
(110 V) 3 Poles in Series, 55 °C 85 A
(110 V) 3 Poles in Series, 70 °C 70 A
(220 V) 3 Poles in Series, 40 °C 50 A
(220 V) 3 Poles in Series, 55 °C 50 A
(220 V) 3 Poles in Series, 70 °C 50 A
(72 V) 1-Pole, 40 °C 50 A
Rated Operational Current DC-13 (Ie):
(24 V) 6 A / 144 W
(48 V) 2.8 A / 134 W
(72 V) 1 A / 72 W
(110 V) 0.55 A / 60 W
(125 V) 0.55 A / 69 W
(220 V) 0.30 A / 66 W
(250 V) 0.3 / 75 W
(24 V) 6 A / 144 W
(48 V) 2.8 A / 134 W
(72 V) 1 A / 72 W
(110 V) 0.55 A / 60 W
(125 V) 0.55 A / 69 W
(220 V) 0.30 A / 66 W
(250 V) 0.3 / 75 W
Rated Operational Power AC-3 (Pe):
(415 V) 25 kW
(440 V) 25 kW
(500 V) 30 kW
(690 V) 30 kW
(380 / 400 V) 22 kW
(220 / 230 / 240 V) 15 kW
(415 V) 25 kW
(440 V) 25 kW
(500 V) 30 kW
(690 V) 30 kW
(380 / 400 V) 22 kW
(220 / 230 / 240 V) 15 kW
Rated Short-time Withstand Current Low Voltage (Icw):
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 650 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 370 A
for 0.1 s 140 A
for 1 s 100 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 650 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 370 A
for 0.1 s 140 A
for 1 s 100 A
Maximum Breaking Capacity:
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A
Rated Insulation Voltage (Ui):
acc. to IEC 60947-4-1 1000 V
acc. to IEC 60947-5-1 690 V
acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 1000 V
acc. to IEC 60947-5-1 690 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp):
8 kV
Rated Control Circuit Voltage (Uc):
DC Operation 20 ... 60 V
Power Loss:
at 6 A per Pole 0.1 W
at Rated Operating Conditions AC-1 per Pole 5 W
at Rated Operating Conditions AC-3 per Pole 1.3 W
at 6 A per Pole 0.1 W
at Rated Operating Conditions AC-1 per Pole 5 W
at Rated Operating Conditions AC-3 per Pole 1.3 W
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH75-25 (75 x 25 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH75-25 (75 x 25 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied) :
2 x M6 Screws Placed Diagonally
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Terminal Type:
Ring-Tongue Terminals
Product Name:
Block Contactor

Technical UL/CSA

NEMA Size:
2
Horsepower Rating NEMA:
(115 V AC) Single Phase 3 Hp
(200 V AC) Three Phase 10 Hp
(230 V AC) Single Phase 7-1/2 Hp
(230 V AC) Three Phase 15 Hp
(460 V AC) Three Phase 25 Hp
(575 V AC) Three Phase 25 Hp
(115 V AC) Single Phase 3 Hp
(200 V AC) Three Phase 10 Hp
(230 V AC) Single Phase 7-1/2 Hp
(230 V AC) Three Phase 15 Hp
(460 V AC) Three Phase 25 Hp
(575 V AC) Three Phase 25 Hp
Maximum Operating Voltage UL/CSA:
Main Circuit 600 V
General Use Rating UL/CSA:
(600 V AC) 80 A
Horsepower Rating UL/CSA:
(120 V AC) Single Phase 3 hp
(200 ... 208 V AC) Three Phase 15 Hp
(220 ... 240 V AC) Three Phase 20 Hp
(240 V AC) Single Phase 7-1/2 hp
(440 ... 480 V AC) Three Phase 40 Hp
(550 ... 600 V AC) Three Phase 50 Hp
(120 V AC) Single Phase 3 hp
(200 ... 208 V AC) Three Phase 15 Hp
(220 ... 240 V AC) Three Phase 20 Hp
(240 V AC) Single Phase 7-1/2 hp
(440 ... 480 V AC) Three Phase 40 Hp
(550 ... 600 V AC) Three Phase 50 Hp

Environmental

Ambient Air Temperature:
Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Maximum Operating Altitude Permissible:
Without Derating 3000 m
Pollution Degree:
3

Material Compliance

Certificates and Declarations

EAC Certificate:
GOST Certificate:

Container Information

Package Level 1 Units:
1 piece
Package Level 1 Width:
140 mm
Package Level 1 Depth / Length:
146 mm
Package Level 1 Height:
96 mm
Package Level 1 Gross Weight:
1.23 kg

External Classifications and Standards

Object Classification Code:
Q
ETIM 7:
EC000066 - Power contactor, AC switching
ETIM 8:
EC000066 - Power contactor, AC switching
ETIM 9:
EC000066 - Power contactor, AC switching
eClass:
V11.0 : 27371003
UNSPSC:
39121529
Price on request
Ask for quote
   

Notify Me When Available

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
8536490065

Dimensions

Product Net Width:
70 mm
Product Net Depth / Length:
108 mm
Product Net Height:
110 mm
Product Net Weight:
1.23 kg

Technical

Number of Main Contacts NO:
3
Number of Main Contacts NC:
0
Number of Auxiliary Contacts NO:
1
Number of Auxiliary Contacts NC:
1
Number of Poles:
3P
Standards:
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 508, CSA C22.2 No. 14, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011 (on request), IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives.
Rated Operational Voltage:
Auxiliary Circuit 690 V
Main Circuit 690 V
Auxiliary Circuit 690 V
Main Circuit 690 V
Rated Operational Current AC-1 (Ie):
(690 V) 40 °C 100 A
(690 V) 55 °C 85 A
(690 V) 70 °C 70 A
(690 V) 40 °C 100 A
(690 V) 55 °C 85 A
(690 V) 70 °C 70 A
Rated Operational Current AC-3 (Ie):
(415 V) 55 °C 50 A
(440 V) 55 °C 45 A
(500 V) 55 °C 45 A
(690 V) 55 °C 35 A
(380 / 400 V) 55 °C 50 A
(220 / 230 / 240 V) 55 °C 53 A
(415 V) 55 °C 50 A
(440 V) 55 °C 45 A
(500 V) 55 °C 45 A
(690 V) 55 °C 35 A
(380 / 400 V) 55 °C 50 A
(220 / 230 / 240 V) 55 °C 53 A
Rated Operational Current AC-15 (Ie):
(24 / 127 V) 6 A
(220 / 240 V) 4 A
(24 / 127 V) 6 A
(220 / 240 V) 4 A
Rated Operational Current DC-1 (Ie):
(110 V) 2 Poles in Series, 40 °C 100 A
(110 V) 2 Poles in Series, 55 °C 85 A
(110 V) 2 Poles in Series, 70 °C 70 A
(110 V) 3 Poles in Series, 40 °C 100 A
(110 V) 3 Poles in Series, 55 °C 85 A
(110 V) 3 Poles in Series, 70 °C 70 A
(220 V) 3 Poles in Series, 40 °C 100 A
(220 V) 3 Poles in Series, 55 °C 85 A
(220 V) 3 Poles in Series, 70 °C 70 A
(72 V) 1-Pole, 40 °C 100 A
(72 V) 1-Pole, 55 °C 85 A
(72 V) 1-Pole, 70 °C 70 A
(72 V) 2 Poles in Series, 40 °C 100 A
(72 V) 2 Poles in Series, 55 °C 85 A
(72 V) 2 Poles in Series, 70 °C 70 A
(72 V) 3 Poles in Series, 40 °C 100 A
(72 V) 3 Poles in Series, 55 °C 85 A
(72 V) 3 Poles in Series, 70 °C 70 A
(110 V) 2 Poles in Series, 40 °C 100 A
(110 V) 2 Poles in Series, 55 °C 85 A
(110 V) 2 Poles in Series, 70 °C 70 A
(110 V) 3 Poles in Series, 40 °C 100 A
(110 V) 3 Poles in Series, 55 °C 85 A
(110 V) 3 Poles in Series, 70 °C 70 A
(220 V) 3 Poles in Series, 40 °C 100 A
(220 V) 3 Poles in Series, 55 °C 85 A
(220 V) 3 Poles in Series, 70 °C 70 A
(72 V) 1-Pole, 40 °C 100 A
Rated Operational Current DC-3 (Ie):
(110 V) 2 Poles in Series, 40 °C 100 A
(110 V) 2 Poles in Series, 55 °C 85 A
(110 V) 2 Poles in Series, 70 °C 70 A
(110 V) 3 Poles in Series, 40 °C 100 A
(110 V) 3 Poles in Series, 55 °C 85 A
(110 V) 3 Poles in Series, 70 °C 70 A
(220 V) 3 Poles in Series, 40 °C 100 A
(220 V) 3 Poles in Series, 55 °C 85 A
(220 V) 3 Poles in Series, 70 °C 70 A
(72 V) 1-Pole, 40 °C 100 A
(72 V) 1-Pole, 55 °C 85 A
(72 V) 1-Pole, 70 °C 70 A
(72 V) 2 Poles in Series, 40 °C 100 A
(72 V) 2 Poles in Series, 55 °C 85 A
(72 V) 2 Poles in Series, 70 °C 70 A
(72 V) 3 Poles in Series, 40 °C 100 A
(72 V) 3 Poles in Series, 55 °C 85 A
(72 V) 3 Poles in Series, 70 °C 70 A
(110 V) 2 Poles in Series, 40 °C 100 A
(110 V) 2 Poles in Series, 55 °C 85 A
(110 V) 2 Poles in Series, 70 °C 70 A
(110 V) 3 Poles in Series, 40 °C 100 A
(110 V) 3 Poles in Series, 55 °C 85 A
(110 V) 3 Poles in Series, 70 °C 70 A
(220 V) 3 Poles in Series, 40 °C 100 A
(220 V) 3 Poles in Series, 55 °C 85 A
(220 V) 3 Poles in Series, 70 °C 70 A
(72 V) 1-Pole, 40 °C 100 A
Rated Operational Current DC-5 (Ie):
(110 V) 2 Poles in Series, 40 °C 80 A
(110 V) 2 Poles in Series, 55 °C 80 A
(110 V) 2 Poles in Series, 70 °C 70 A
(110 V) 3 Poles in Series, 40 °C 100 A
(110 V) 3 Poles in Series, 55 °C 85 A
(110 V) 3 Poles in Series, 70 °C 70 A
(220 V) 3 Poles in Series, 40 °C 50 A
(220 V) 3 Poles in Series, 55 °C 50 A
(220 V) 3 Poles in Series, 70 °C 50 A
(72 V) 1-Pole, 40 °C 50 A
(72 V) 1-Pole, 55 °C 50 A
(72 V) 1-Pole, 70 °C 50 A
(72 V) 2 Poles in Series, 40 °C 100 A
(72 V) 2 Poles in Series, 55 °C 85 A
(72 V) 2 Poles in Series, 70 °C 70 A
(72 V) 3 Poles in Series, 40 °C 100 A
(72 V) 3 Poles in Series, 55 °C 85 A
(72 V) 3 Poles in Series, 70 °C 70 A
(110 V) 2 Poles in Series, 40 °C 80 A
(110 V) 2 Poles in Series, 55 °C 80 A
(110 V) 2 Poles in Series, 70 °C 70 A
(110 V) 3 Poles in Series, 40 °C 100 A
(110 V) 3 Poles in Series, 55 °C 85 A
(110 V) 3 Poles in Series, 70 °C 70 A
(220 V) 3 Poles in Series, 40 °C 50 A
(220 V) 3 Poles in Series, 55 °C 50 A
(220 V) 3 Poles in Series, 70 °C 50 A
(72 V) 1-Pole, 40 °C 50 A
Rated Operational Current DC-13 (Ie):
(24 V) 6 A / 144 W
(48 V) 2.8 A / 134 W
(72 V) 1 A / 72 W
(110 V) 0.55 A / 60 W
(125 V) 0.55 A / 69 W
(220 V) 0.30 A / 66 W
(250 V) 0.3 / 75 W
(24 V) 6 A / 144 W
(48 V) 2.8 A / 134 W
(72 V) 1 A / 72 W
(110 V) 0.55 A / 60 W
(125 V) 0.55 A / 69 W
(220 V) 0.30 A / 66 W
(250 V) 0.3 / 75 W
Rated Operational Power AC-3 (Pe):
(415 V) 25 kW
(440 V) 25 kW
(500 V) 30 kW
(690 V) 30 kW
(380 / 400 V) 22 kW
(220 / 230 / 240 V) 15 kW
(415 V) 25 kW
(440 V) 25 kW
(500 V) 30 kW
(690 V) 30 kW
(380 / 400 V) 22 kW
(220 / 230 / 240 V) 15 kW
Rated Short-time Withstand Current Low Voltage (Icw):
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 650 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 370 A
for 0.1 s 140 A
for 1 s 100 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 650 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 370 A
for 0.1 s 140 A
for 1 s 100 A
Maximum Breaking Capacity:
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A
Rated Insulation Voltage (Ui):
acc. to IEC 60947-4-1 1000 V
acc. to IEC 60947-5-1 690 V
acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 1000 V
acc. to IEC 60947-5-1 690 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp):
8 kV
Rated Control Circuit Voltage (Uc):
DC Operation 20 ... 60 V
Power Loss:
at 6 A per Pole 0.1 W
at Rated Operating Conditions AC-1 per Pole 5 W
at Rated Operating Conditions AC-3 per Pole 1.3 W
at 6 A per Pole 0.1 W
at Rated Operating Conditions AC-1 per Pole 5 W
at Rated Operating Conditions AC-3 per Pole 1.3 W
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH75-25 (75 x 25 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH75-25 (75 x 25 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied) :
2 x M6 Screws Placed Diagonally
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Terminal Type:
Ring-Tongue Terminals
Product Name:
Block Contactor

Technical UL/CSA

NEMA Size:
2
Horsepower Rating NEMA:
(115 V AC) Single Phase 3 Hp
(200 V AC) Three Phase 10 Hp
(230 V AC) Single Phase 7-1/2 Hp
(230 V AC) Three Phase 15 Hp
(460 V AC) Three Phase 25 Hp
(575 V AC) Three Phase 25 Hp
(115 V AC) Single Phase 3 Hp
(200 V AC) Three Phase 10 Hp
(230 V AC) Single Phase 7-1/2 Hp
(230 V AC) Three Phase 15 Hp
(460 V AC) Three Phase 25 Hp
(575 V AC) Three Phase 25 Hp
Maximum Operating Voltage UL/CSA:
Main Circuit 600 V
General Use Rating UL/CSA:
(600 V AC) 80 A
Horsepower Rating UL/CSA:
(120 V AC) Single Phase 3 hp
(200 ... 208 V AC) Three Phase 15 Hp
(220 ... 240 V AC) Three Phase 20 Hp
(240 V AC) Single Phase 7-1/2 hp
(440 ... 480 V AC) Three Phase 40 Hp
(550 ... 600 V AC) Three Phase 50 Hp
(120 V AC) Single Phase 3 hp
(200 ... 208 V AC) Three Phase 15 Hp
(220 ... 240 V AC) Three Phase 20 Hp
(240 V AC) Single Phase 7-1/2 hp
(440 ... 480 V AC) Three Phase 40 Hp
(550 ... 600 V AC) Three Phase 50 Hp

Environmental

Ambient Air Temperature:
Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Maximum Operating Altitude Permissible:
Without Derating 3000 m
Pollution Degree:
3

Material Compliance

Certificates and Declarations

EAC Certificate:
GOST Certificate:

Container Information

Package Level 1 Units:
1 piece
Package Level 1 Width:
140 mm
Package Level 1 Depth / Length:
146 mm
Package Level 1 Height:
96 mm
Package Level 1 Gross Weight:
1.23 kg

External Classifications and Standards

Object Classification Code:
Q
ETIM 7:
EC000066 - Power contactor, AC switching
ETIM 8:
EC000066 - Power contactor, AC switching
ETIM 9:
EC000066 - Power contactor, AC switching
eClass:
V11.0 : 27371003
UNSPSC:
39121529
Object Classification Code:
Q
ETIM 7:
EC000066 - Power contactor, AC switching
ETIM 8:
EC000066 - Power contactor, AC switching
ETIM 9:
EC000066 - Power contactor, AC switching
eClass:
V11.0 : 27371003
UNSPSC:
39121529

All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.

If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.

In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.

PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.

Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.

PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.

Trusted By

"Fast service for obsolete parts"

Increasingly PLC/ HMI control platforms are becoming obsolete and parts are no longer supported, however PLC Direct had the HMI we needed and fast shipping for our system to get back online!

Buyer at GE Health

"Helping us move projects forward"

With supply chain issues increasingly affecting our business, PLC Direct has been there for us to supply the PLC products we need, when we need it. If they don't have it readily available, they find it and provide it quickly and reliably. This has helped us move forward with several projects that would have otherwise taken us many, many months to complete.

Buyer at E-Merge Systems – A Rockwell Integrator