1SAT125000R1011 ABB HF2.4-ROL-24VDC

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85371098
Product Main Type:
HF
Product Name:
Electronic Starter

Dimensions

Product Net Width:
22.5 mm
Product Net Height:
99 mm
Product Net Depth / Length:
114.5 mm
Product Net Weight:
0.219 kg

Technical

Standards:
IEC/EN 60947-1
IEC/EN 60947-4-2
UL 60947-1
UL 60947-4-2
IEC/EN 60947-1
IEC/EN 60947-4-2
UL 60947-1
UL 60947-4-2
Function:
Reversed-on-line starter with overload protection
Utilization:
Motor Protection
Rated Operational Voltage:
Main Circuit 500 V AC
Operational Voltage:
Maximum 550 V AC
Minimum 42 V AC
Maximum 550 V AC
Minimum 42 V AC
Rated Frequency (f):
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit 50 Hz
Main Circuit 60 Hz
Rated Control Supply Voltage (Us):
24 V DC
Rated Input Voltage (UIN):
Switching Threshold at Signal <0> -3 ... 9.6 V
Switching Threshold at Signal <1> 19.2 ... 30 V
Switching Threshold at Signal <0> -3 ... 9.6 V
Switching Threshold at Signal <1> 19.2 ... 30 V
Rated Impulse Withstand Voltage (Uimp):
Main Circuit 6 kV
Rated Insulation Voltage (Ui):
500 V
Rated Operational Current AC-51 (Ie):
2.4 A
Rated Operational Current AC-53a (Ie):
2.4 A
Rated Control Supply Current (Is):
0.04 A
Rated Uninterrupted Current (Iu):
2.4 A
Input Current:
0.003 A
Switching Frequency:
≤ 2 Hz
120 starts/min
7200 starts/h
≤ 2 Hz
120 starts/min
7200 starts/h
Rated Operational Power AC-53a (Pe):
0.75 kW
Overvoltage Category:
III
Overload Protection:
Electronic overload protection
Setting Range:
0.18 ... 2.4 A
Trip Class:
class 10A
Number of Poles:
3P
Power Loss:
Maximum 3.3 W
Minimum 1.1 W
Maximum 3.3 W
Minimum 1.1 W
Number of Protected Poles:
3
Mechanical Durability:
Nr. Operations 10000 cycle
Electrical Durability:
30000000 cycle
Delay Time (τ):
Off, Maximum, Switched Off via Supply Voltage 500 ms
Off, Typical, Switched Off via Control Input Voltage 30 ms
Off, Typical, Switched Off via Supply Voltage 25 ms
Off, Maximum, Switched Off with Pushbutton 3 second [unit of time]
Off, Minimum, Switched Off with Pushbutton 0.5 second [unit of time]
Off, Maximum, Switched Off via Supply Voltage 500 ms
Off, Typical, Switched Off via Control Input Voltage 30 ms
Off, Typical, Switched Off via Supply Voltage 25 ms
Off, Maximum, Switched Off with Pushbutton 3 second [unit of time]
Off, Minimum, Switched Off with Pushbutton 0.5 second [unit of time]
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting Position:
1
Connecting Capacity Control Circuit:
Flexible with Ferrule 1/2x 1 ... 2.5 mm²
Flexible 1/2x 1 ... 2.5 mm²
Rigid 1x 0.5 ... 4 mm²
Flexible with Ferrule 1/2x 1 ... 2.5 mm²
Flexible 1/2x 1 ... 2.5 mm²
Rigid 1x 0.5 ... 4 mm²
Connecting Capacity Main Circuit:
Flexible with Ferrule 1x 2 ... 2.5 mm²
Flexible 1x 2 ... 2.5 mm²
Rigid 1x 2 ... 2.5 mm²
Flexible with Ferrule 1x 2 ... 2.5 mm²
Flexible 1x 2 ... 2.5 mm²
Rigid 1x 2 ... 2.5 mm²
Recommended Screw Driver:
Control Circuit M3
Main Circuit M3
Control Circuit M3
Main Circuit M3
Terminal Type:
Screw Terminals
Tightening Torque:
Control Circuit 0.5 ... 0.6 N·m
Main Circuit 0.5 ... 0.6 N·m
Control Circuit 0.5 ... 0.6 N·m
Main Circuit 0.5 ... 0.6 N·m
Wire Stripping Length:
Control Circuit 8 mm
Main Circuit 8 mm
Control Circuit 8 mm
Main Circuit 8 mm
Response Time:
Phase Asymmetry 33% 120 second [unit of time]
Phase Asymmetry 67% 1.8 second [unit of time]
Phase Failure 1.8 second [unit of time]
Phase Asymmetry 33% 120 second [unit of time]
Phase Asymmetry 67% 1.8 second [unit of time]
Phase Failure 1.8 second [unit of time]
Pollution Degree:
2
Phase Loss Sensitive:
Yes
Degree of Protection:
Housing IP20
Main Circuit Terminals IP20
Housing IP20
Main Circuit Terminals IP20
Short-Circuit Current Rating (SCCR):
(500 V AC, 30 A Class J or CC) 100 kA

Technical UL/CSA

Maximum Operating Voltage UL/CSA:
Main Circuit 500 V AC
Horsepower Rating UL/CSA:
Nominal Switching Performance Full Load (power factor = 0.4) 1.2 Hp
Nominal Switching Performance Full Load (power factor = 0.8) 2.2 Hp
Nominal Switching Performance Full Load (power factor = 0.4) 1.2 Hp
Nominal Switching Performance Full Load (power factor = 0.8) 2.2 Hp
Full Load Amps Motor Use:
2.4 A
Connecting Capacity Main Circuit UL/CSA:
Flexible with Ferrule 1x 24 ... 14 AWG
Flexible 1x 24 ... 14 AWG
Solid 1x 24 ... 14 AWG
Flexible with Ferrule 1x 24 ... 14 AWG
Flexible 1x 24 ... 14 AWG
Solid 1x 24 ... 14 AWG
Connecting Capacity Control Circuit UL/CSA:
Flexible with Ferrule 1x 24 ... 14 AWG
Flexible 16-8 AWG
Solid 1x 24 ... 14 AWG
Flexible with Ferrule 1x 24 ... 14 AWG
Flexible 16-8 AWG
Solid 1x 24 ... 14 AWG
Tightening Torque UL/CSA:
Control Circuit 5 ... 7 in·lb
Main Circuit 5 ... 7 in·lb
Control Circuit 5 ... 7 in·lb
Main Circuit 5 ... 7 in·lb

Safety Information

Mean Time to Failure (MTTF):
39.6 year

Environmental

Ambient Air Temperature:
Operation -25 ... +70 °C
Operation Compensated -40 ... + 80 °C
Operation -25 ... +70 °C
Operation Compensated -40 ... + 80 °C
Maximum Operating Altitude Permissible:
Without Derating 2000 m

Material Compliance

Conflict Minerals Reporting Template (CMRT):
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
WEEE B2C / B2B:
Business To Business
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
150 mm
Package Level 1 Depth / Length:
115 mm
Package Level 1 Height:
34 mm
Package Level 1 Gross Weight:
0.319 kg
Package Level 1 EAN:
4013614515552

External Classifications and Standards

Object Classification Code:
B
ETIM 9:
EC001037 - Motor starter/motor starter combination
ETIM 10:
EC001037 - Motor starter/motor starter combination
eClass:
V11.0 : 27370905
UNSPSC:
39121521
IDEA Granular Category Code (IGCC):
4727 >> Motor starter controls
E-Number (Finland):
3707548
E-Number (Norway):
4102014
E-Number (Sweden):
3210496
Price on request
Ask for quote
   

Notify Me When Available

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85371098
Product Main Type:
HF
Product Name:
Electronic Starter

Dimensions

Product Net Width:
22.5 mm
Product Net Height:
99 mm
Product Net Depth / Length:
114.5 mm
Product Net Weight:
0.219 kg

Technical

Standards:
IEC/EN 60947-1
IEC/EN 60947-4-2
UL 60947-1
UL 60947-4-2
IEC/EN 60947-1
IEC/EN 60947-4-2
UL 60947-1
UL 60947-4-2
Function:
Reversed-on-line starter with overload protection
Utilization:
Motor Protection
Rated Operational Voltage:
Main Circuit 500 V AC
Operational Voltage:
Maximum 550 V AC
Minimum 42 V AC
Maximum 550 V AC
Minimum 42 V AC
Rated Frequency (f):
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit 50 Hz
Main Circuit 60 Hz
Rated Control Supply Voltage (Us):
24 V DC
Rated Input Voltage (UIN):
Switching Threshold at Signal <0> -3 ... 9.6 V
Switching Threshold at Signal <1> 19.2 ... 30 V
Switching Threshold at Signal <0> -3 ... 9.6 V
Switching Threshold at Signal <1> 19.2 ... 30 V
Rated Impulse Withstand Voltage (Uimp):
Main Circuit 6 kV
Rated Insulation Voltage (Ui):
500 V
Rated Operational Current AC-51 (Ie):
2.4 A
Rated Operational Current AC-53a (Ie):
2.4 A
Rated Control Supply Current (Is):
0.04 A
Rated Uninterrupted Current (Iu):
2.4 A
Input Current:
0.003 A
Switching Frequency:
≤ 2 Hz
120 starts/min
7200 starts/h
≤ 2 Hz
120 starts/min
7200 starts/h
Rated Operational Power AC-53a (Pe):
0.75 kW
Overvoltage Category:
III
Overload Protection:
Electronic overload protection
Setting Range:
0.18 ... 2.4 A
Trip Class:
class 10A
Number of Poles:
3P
Power Loss:
Maximum 3.3 W
Minimum 1.1 W
Maximum 3.3 W
Minimum 1.1 W
Number of Protected Poles:
3
Mechanical Durability:
Nr. Operations 10000 cycle
Electrical Durability:
30000000 cycle
Delay Time (τ):
Off, Maximum, Switched Off via Supply Voltage 500 ms
Off, Typical, Switched Off via Control Input Voltage 30 ms
Off, Typical, Switched Off via Supply Voltage 25 ms
Off, Maximum, Switched Off with Pushbutton 3 second [unit of time]
Off, Minimum, Switched Off with Pushbutton 0.5 second [unit of time]
Off, Maximum, Switched Off via Supply Voltage 500 ms
Off, Typical, Switched Off via Control Input Voltage 30 ms
Off, Typical, Switched Off via Supply Voltage 25 ms
Off, Maximum, Switched Off with Pushbutton 3 second [unit of time]
Off, Minimum, Switched Off with Pushbutton 0.5 second [unit of time]
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting Position:
1
Connecting Capacity Control Circuit:
Flexible with Ferrule 1/2x 1 ... 2.5 mm²
Flexible 1/2x 1 ... 2.5 mm²
Rigid 1x 0.5 ... 4 mm²
Flexible with Ferrule 1/2x 1 ... 2.5 mm²
Flexible 1/2x 1 ... 2.5 mm²
Rigid 1x 0.5 ... 4 mm²
Connecting Capacity Main Circuit:
Flexible with Ferrule 1x 2 ... 2.5 mm²
Flexible 1x 2 ... 2.5 mm²
Rigid 1x 2 ... 2.5 mm²
Flexible with Ferrule 1x 2 ... 2.5 mm²
Flexible 1x 2 ... 2.5 mm²
Rigid 1x 2 ... 2.5 mm²
Recommended Screw Driver:
Control Circuit M3
Main Circuit M3
Control Circuit M3
Main Circuit M3
Terminal Type:
Screw Terminals
Tightening Torque:
Control Circuit 0.5 ... 0.6 N·m
Main Circuit 0.5 ... 0.6 N·m
Control Circuit 0.5 ... 0.6 N·m
Main Circuit 0.5 ... 0.6 N·m
Wire Stripping Length:
Control Circuit 8 mm
Main Circuit 8 mm
Control Circuit 8 mm
Main Circuit 8 mm
Response Time:
Phase Asymmetry 33% 120 second [unit of time]
Phase Asymmetry 67% 1.8 second [unit of time]
Phase Failure 1.8 second [unit of time]
Phase Asymmetry 33% 120 second [unit of time]
Phase Asymmetry 67% 1.8 second [unit of time]
Phase Failure 1.8 second [unit of time]
Pollution Degree:
2
Phase Loss Sensitive:
Yes
Degree of Protection:
Housing IP20
Main Circuit Terminals IP20
Housing IP20
Main Circuit Terminals IP20
Short-Circuit Current Rating (SCCR):
(500 V AC, 30 A Class J or CC) 100 kA

Technical UL/CSA

Maximum Operating Voltage UL/CSA:
Main Circuit 500 V AC
Horsepower Rating UL/CSA:
Nominal Switching Performance Full Load (power factor = 0.4) 1.2 Hp
Nominal Switching Performance Full Load (power factor = 0.8) 2.2 Hp
Nominal Switching Performance Full Load (power factor = 0.4) 1.2 Hp
Nominal Switching Performance Full Load (power factor = 0.8) 2.2 Hp
Full Load Amps Motor Use:
2.4 A
Connecting Capacity Main Circuit UL/CSA:
Flexible with Ferrule 1x 24 ... 14 AWG
Flexible 1x 24 ... 14 AWG
Solid 1x 24 ... 14 AWG
Flexible with Ferrule 1x 24 ... 14 AWG
Flexible 1x 24 ... 14 AWG
Solid 1x 24 ... 14 AWG
Connecting Capacity Control Circuit UL/CSA:
Flexible with Ferrule 1x 24 ... 14 AWG
Flexible 16-8 AWG
Solid 1x 24 ... 14 AWG
Flexible with Ferrule 1x 24 ... 14 AWG
Flexible 16-8 AWG
Solid 1x 24 ... 14 AWG
Tightening Torque UL/CSA:
Control Circuit 5 ... 7 in·lb
Main Circuit 5 ... 7 in·lb
Control Circuit 5 ... 7 in·lb
Main Circuit 5 ... 7 in·lb

Safety Information

Mean Time to Failure (MTTF):
39.6 year

Environmental

Ambient Air Temperature:
Operation -25 ... +70 °C
Operation Compensated -40 ... + 80 °C
Operation -25 ... +70 °C
Operation Compensated -40 ... + 80 °C
Maximum Operating Altitude Permissible:
Without Derating 2000 m

Material Compliance

Conflict Minerals Reporting Template (CMRT):
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
WEEE B2C / B2B:
Business To Business
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
150 mm
Package Level 1 Depth / Length:
115 mm
Package Level 1 Height:
34 mm
Package Level 1 Gross Weight:
0.319 kg
Package Level 1 EAN:
4013614515552

External Classifications and Standards

Object Classification Code:
B
ETIM 9:
EC001037 - Motor starter/motor starter combination
ETIM 10:
EC001037 - Motor starter/motor starter combination
eClass:
V11.0 : 27370905
UNSPSC:
39121521
IDEA Granular Category Code (IGCC):
4727 >> Motor starter controls
E-Number (Finland):
3707548
E-Number (Norway):
4102014
E-Number (Sweden):
3210496
Object Classification Code:
B
ETIM 9:
EC001037 - Motor starter/motor starter combination
ETIM 10:
EC001037 - Motor starter/motor starter combination
eClass:
V11.0 : 27370905
UNSPSC:
39121521
IDEA Granular Category Code (IGCC):
4727 >> Motor starter controls
E-Number (Finland):
3707548
E-Number (Norway):
4102014
E-Number (Sweden):
3210496

All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.

If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.

In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.

PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.

Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.

PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.

Trusted By

"Fast service for obsolete parts"

Increasingly PLC/ HMI control platforms are becoming obsolete and parts are no longer supported, however PLC Direct had the HMI we needed and fast shipping for our system to get back online!

Buyer at GE Health

"Helping us move projects forward"

With supply chain issues increasingly affecting our business, PLC Direct has been there for us to supply the PLC products we need, when we need it. If they don't have it readily available, they find it and provide it quickly and reliably. This has helped us move forward with several projects that would have otherwise taken us many, many months to complete.

Buyer at E-Merge Systems – A Rockwell Integrator