Specifications
Model |
DX-W600 |
|||
Controller |
CPU |
Intel® Quad Core + Scan processor |
||
OS |
Windows® 10 IoT Enterprise |
|||
Main Memory |
RAM/ROM |
4 GB RAM, 64 GB ROM |
||
Display |
LCD |
6.0-inch, 720 × 1440 |
||
Operation Status LED |
3-color LED |
|||
Operations |
Hard Keys |
Trigger key × 2, Volume up/down keys, Power key, Side Fn key × 2 |
||
Touch Panel |
Electrostatic capacitance method (Tempered glass) |
|||
Scanner |
Reading Light Source |
High-intensity white LED |
||
Pointer Light Source |
Visible semiconductor laser (655 nm), Output: 390 μW, Class 1 laser product (JIS C 6802) (IEC 60825-1) |
|||
Minimum Resolution |
2D code: 0.169 mm 0.0067", Barcode: 0.076 mm 0.0030" |
|||
Field Range |
186 × 114 mm 7.32" × 4.49" (Reading distance: 200 mm 7.87") |
|||
Supported Codes |
UPC/EAN/JAN (add-on code support), CODE128, GS1-128, CODE39, Codabar (NW-7), CODE93, ITF, COOP 2of5, Industrial 2of5, |
|||
Communication |
Wireless LAN |
IEEE 802.11 a/b/g/n/ac, |
||
Bluetooth |
Bluetooth Ver. 4.2 BR/EDR/LE |
|||
WWAN |
— |
|||
GNSS | ||||
NFC |
ISO 14443 Type A, B, FeliCa, ISO 15693 |
|||
Supported Media |
microSD/SDHC/SDXC UHS-I |
|||
Power Source |
Main Battery |
Dedicated lithium-ion battery pack |
||
Backup Battery |
Built-in lithium secondary battery: Approx. 1 month*2 |
|||
Other |
Microphone |
1 |
||
Speaker |
Speaker × 1, Receiver × 1 |
|||
Vibration |
Available |
|||
Camera |
Rear Camera: 8 MP-AF, Front Camera: 5 MP |
|||
Sensor |
Accelerometer, Gyroscope, Ambient light, Proximity, |
|||
Environmental resistance |
Ambient temperature |
-5 to +50°C 23 to +122°F, Charging: 0 to +40°C 32 to 104°F*3 |
||
Relative humidity |
20 to 85% RH (No condensation) |
|||
Storage temperature |
-20 to +60°C -4 to +140°F (No freezing) |
|||
Storage relative humidity |
20 to 85% RH (No condensation) |
|||
Dimensions |
175.5 × 85.9 × 31.5 mm 6.91" × 3.38" × 1.24" |
|||
Weight |
Approx. 230 g 8.12 oz |
|||
*1 The usable frequency band varies depending on the region. | ||||

Specifications
Model |
EA-300 |
|||
Analysis optical system |
Detection principle |
Laser-induced breakdown spectroscopy |
||
Supported elements |
H1 to U92 |
|||
Laser |
Laser type |
Nd: YAG laser |
||
Laser class |
Class 1 laser product (IEC/EN 60825-1, JIS C 6802, FDA (CDRH) Part 1040.10) |
|||
Laser wavelength |
355 nm |
|||
Spot size |
10 μm (typ.) |
|||
Observation optical system |
Image sensor |
1/1.8-inch, 3.19-megapixel CMOS image sensor |
||
Observation magnification |
300× to 1000× |
|||
Scanning system |
Progressive |
|||
Frame rate |
50 fps (max.) |
|||
Optical system |
Lens type |
Specially designed reflective objective lens |
||
Objective lens working distance |
25 mm 0.98" |
|||
High dynamic range |
16-bit intensity range through RGB data from each pixel |
|||
Gain |
Manual, Preset |
|||
Electronic shutter |
Auto, Manual, 1/60, 1/120, 1/250, 1/500, 1/1000, 1/2000, 1/5000, 1/9000, 1/19000 |
|||
Supercharge shutter |
Can be set in 0.01 s increments from 0.02 to 16 s |
|||
White balance |
Push-set, Manual, Preset (2700K, 3200K, 5600K, 9000K) |
|||
Built-in coaxial illumination light source |
Type |
High-brightness LED |
||
Service life |
100000 hours (reference value) |
|||
Color temperature |
5810K (typ.) |
|||
Built-in ring illumination light source |
Type |
High-brightness LED |
||
Service life |
100000 hours (reference value) |
|||
Color temperature |
5810K (typ.) |
|||
Power supply |
Power supply method |
Power supplied via dedicated cable from VHX Series controller camera port |
||
Environmental resistance |
Ambient temperature |
10 to 33°C 50.0°F to 91.4°F |
||
Relative humidity |
35 to 80% RH (No condensation) |
|||
Dimensions |
280 (W) × 375 (H) × 210 (D) mm 11.02"(W) × 14.76" (H) × 8.27" (D) (with lens stored) (excluding protrusions) |
|||
Weight |
Approx. 7.2 kg 15.87 lb (Analysis system main unit) |
|||

Specifications
Model |
ED-118M |
|||
Type |
Shielded |
|||
Shape |
M18Threaded type |
|||
Detecting distance |
5 mm 0.20" ±15% |
|||
Detectable object |
All metals *1 |
|||
Standard target (aluminum, t=1 mm 0.04") |
18 x 18 mm 0.71" x 0.71" |
|||
Hysteresis |
15% max. of detecting distance |
|||
Response frequency |
100 Hz |
|||
Operation mode |
N.O. |
|||
Indicator lamp |
Operation indicator: Red LED, Stable operation indicator: Green LED |
|||
Temperature characteristics |
±20% max. of detecting distance at 23°C 73.4°F, within 0 to 50°C 32 to 122°F |
|||
Control output |
NPN open collector 100 mA max. (40 V max.), Residual voltage: 1 V max. |
|||
Protection circuit |
Reversed polarity, surge absorber |
|||
Rating |
Power voltage |
12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less |
||
Current consumption |
35 mA or less |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Ambient temperature |
0 to +50 °C 32 to 122 °F (No freezing) |
|||
Relative humidity |
35 to 95 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
1,000 m/s2, 3 times in each of the X, Y, and Z directions |
|||
Case material |
Nickel-plated brass |
|||
Accessories |
Screw nut x 2, |
|||
Weight |
Approx. 150 g (including 2-m 6.6' cable and nuts) |
|||
*1 When detecting ferrous metals, the detecting distance may decrease. | ||||

Specifications
Model |
ED-118U |
|||
Type |
Non-shielded |
|||
Shape |
M18Threaded type |
|||
Detecting distance |
11 mm 0.43" ±15% |
|||
Detectable object |
All metals *1 |
|||
Standard target (aluminum, t=1 mm 0.04") |
50 x 50 mm 1.97" |
|||
Hysteresis |
15% max. of detecting distance |
|||
Response frequency |
200 Hz |
|||
Operation mode |
N.O. |
|||
Indicator lamp |
Operation indicator: Red LED, Stable operation indicator: Green LED |
|||
Temperature characteristics |
±20% max. of detecting distance at 23°C 73.4°F, within 0 to 50°C 32 to 122°F |
|||
Control output |
NPN open collector 100 mA max. (40 V max.), Residual voltage: 1 V max. |
|||
Protection circuit |
Reversed polarity, surge absorber |
|||
Rating |
Power voltage |
12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less |
||
Current consumption |
35 mA or less |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Ambient temperature |
0 to +50 °C 32 to 122 °F (No freezing) |
|||
Relative humidity |
35 to 95 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
1,000 m/s2, 3 times in each of the X, Y, and Z directions |
|||
Case material |
Nickel-plated brass |
|||
Accessories |
Screw nut x 2, |
|||
Weight |
Approx. 140 g (including 2-m 6.6' cable and nuts) |
|||
*1 When detecting ferrous metals, the detecting distance may decrease. | ||||

Specifications
Model |
ED-130M |
|||
Type |
Shielded |
|||
Shape |
M30Threaded type |
|||
Detecting distance |
11 mm 0.43" ±15% |
|||
Detectable object |
All metals *1 |
|||
Standard target (aluminum, t=1 mm 0.04") |
30 x 30 mm 1.18" x 1.18" |
|||
Hysteresis |
15% max. of detecting distance |
|||
Response frequency |
150 Hz |
|||
Operation mode |
N.O. |
|||
Indicator lamp |
Operation indicator: Red LED, Stable operation indicator: Green LED |
|||
Temperature characteristics |
±20% max. of detecting distance at 23°C 73.4°F, within 0 to 50°C 32 to 122°F |
|||
Control output |
NPN open collector 100 mA max. (40 V max.), Residual voltage: 1 V max. |
|||
Protection circuit |
Reversed polarity, surge absorber |
|||
Rating |
Power voltage |
12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less |
||
Current consumption |
35 mA or less |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Ambient temperature |
0 to +50 °C 32 to 122 °F (No freezing) |
|||
Relative humidity |
35 to 95 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
1,000 m/s2, 3 times in each of the X, Y, and Z directions |
|||
Case material |
Nickel-plated brass |
|||
Accessories |
Screw nut x 2, |
|||
Weight |
Approx. 300 g (including 2-m 6.6' cable and nuts) |
|||
*1 When detecting ferrous metals, the detecting distance may decrease. | ||||

Specifications
Model |
ED-130U |
|||
Type |
Non-shielded |
|||
Shape |
M30Threaded type |
|||
Detecting distance |
20 mm 0.79" ±15% |
|||
Detectable object |
All metals *1 |
|||
Standard target (aluminum, t=1 mm 0.04") |
70 x 70 mm 2.76" |
|||
Hysteresis |
15% max. of detecting distance |
|||
Response frequency |
150 Hz |
|||
Operation mode |
N.O. |
|||
Indicator lamp |
Operation indicator: Red LED, Stable operation indicator: Green LED |
|||
Temperature characteristics |
±20% max. of detecting distance at 23°C 73.4°F, within 0 to 50°C 32 to 122°F |
|||
Control output |
NPN open collector 100 mA max. (40 V max.), Residual voltage: 1 V max. |
|||
Protection circuit |
Reversed polarity, surge absorber |
|||
Rating |
Power voltage |
12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less |
||
Current consumption |
35 mA or less |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Ambient temperature |
0 to +50 °C 32 to 122 °F (No freezing) |
|||
Relative humidity |
35 to 95 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
1,000 m/s2, 3 times in each of the X, Y, and Z directions |
|||
Case material |
Nickel-plated brass |
|||
Accessories |
Screw nut x 2, |
|||
Weight |
Approx. 270 g (including 2-m 6.6' cable and nuts) |
|||
*1 When detecting ferrous metals, the detecting distance may decrease. | ||||

Specifications
Model |
EG-520 |
|||
Type |
DC |
|||
Sensitivity adjustment |
15-turn trimmer |
|||
Function |
Operation mode |
N.O./N.C. (switch-selectable) |
||
Operation mode |
External synchronization |
― |
||
Output |
Control output 1 (NPN) |
200 mA max. |
||
Control output 2 |
― |
|||
Disconnection alarm output | ||||
Response |
1 ms |
|||
― | ||||
OFF-delay time | ||||
Temperature characteristics |
0.08%/°C*1 |
|||
Rating |
Power voltage |
11 to 30 VDC, Ripple (P-P) 10 % or less |
||
Power consumption |
100 mA max. |
|||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Weight |
Approx. 110 g |
|||
*1 Above values obtained when the detecting distance is set at 50% of the maximum stable detecting distance. | ||||

Specifications
Model |
EG-530 |
|||
Type |
DC |
|||
Sensitivity adjustment |
15-turn trimmer |
|||
Function |
Operation mode |
N.O./N.C. (switch-selectable) |
||
Operation mode |
External synchronization |
― |
||
Output |
Control output 1 (NPN) |
100 mA max. (40 V max.) Residual voltage: 1 V max. |
||
Control output 2 |
― |
|||
Disconnection alarm output |
100 mA max. |
|||
Response |
1 ms |
|||
― | ||||
OFF-delay time | ||||
Temperature characteristics |
0.08%/°C*1 |
|||
Rating |
Power voltage |
12 to 24 VDC, Ripple (P-P) 10 % or less |
||
Power consumption |
100 mA max. |
|||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Weight |
Approx. 75 g |
|||
*1 Above values obtained when the detecting distance is set at 50% of the maximum stable detecting distance. | ||||

Specifications
Model |
EG-540*1 |
|||
Type |
AC |
|||
Sensitivity adjustment |
15-turn trimmer |
|||
Function |
Operation mode |
N.O./N.C. switch-selectable |
||
Operation mode |
External synchronization |
Equipment (contact output only) |
||
Output |
Control output 1 (NPN) |
100 mA max. (40 V max.) Residual voltage: 1 V max. |
||
Control output 2 |
SPDT, 250 VAC, 2 A max. (resistive load) |
|||
Disconnection alarm output |
― |
|||
Response |
1 ms |
|||
10 ms | ||||
OFF-delay time |
65 ms (contact output only) |
|||
Temperature characteristics |
0.08%/°C*2 |
|||
Rating |
Power voltage |
110/120/220/240 VAC ±10 %, 50/60 Hz |
||
Power consumption |
5 VA max. |
|||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Weight |
Approx. 330 g |
|||
*1 This product does not comply with EMC directives. | ||||


Specifications
Model |
EG-545*1 |
|||
Type |
AC adj-dial |
|||
Sensitivity adjustment |
10-turn potentiometer dial |
|||
Function |
Operation mode |
N.O./N.C. switch-selectable |
||
Operation mode |
External synchronization |
Equipment (contact output only) |
||
Output |
Control output 1 (NPN) |
100 mA max. (40 V max.) Residual voltage: 1 V max. |
||
Control output 2 |
SPDT, 250 VAC, 2 A max. (resistive load) |
|||
Disconnection alarm output |
― |
|||
Response |
1 ms |
|||
10 ms | ||||
OFF-delay time |
65 ms (contact output only) |
|||
Temperature characteristics |
0.08%/°C*2 |
|||
Rating |
Power voltage |
110/120/220/240 VAC ±10 %, 50/60 Hz |
||
Power consumption |
5 VA max. |
|||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Weight |
Approx. 350 g |
|||
*1 This product does not comply with EMC directives. | ||||

Specifications
Model |
EG-545U |
|||
Type |
AC adj-dial |
|||
Sensitivity adjustment |
10-turn potentiometer dial |
|||
Function |
Operation mode |
N.O./N.C. switch-selectable |
||
Operation mode |
External synchronization |
Equipment (contact output only) |
||
Output |
Control output 1 (NPN) |
100 mA max. (40 V max.) Residual voltage: 1 V max. |
||
Control output 2 |
SPDT, 250 VAC, 2 A max. (resistive load) |
|||
Disconnection alarm output |
― |
|||
Response |
1 ms |
|||
10 ms | ||||
OFF-delay time |
65 ms (contact output only) |
|||
Temperature characteristics |
0.08%/°C*1 |
|||
Rating |
Power voltage |
110/120/220/240 VAC ±10 %, 50/60 Hz |
||
Power consumption |
5 VA max. |
|||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Weight |
Approx. 350 g |
|||
*1 Above values obtained when the detecting distance is set at 50% of the maximum stable detecting distance. | ||||

Specifications
Model |
EG-547*1 |
|||
Type |
AC, tolerance setting*2 |
|||
Sensitivity adjustment |
10-turn potentiometer dial |
|||
Function |
Operation mode |
External synchronization, |
||
Operation mode |
External synchronization |
Equipment (both without contacts and with contacts) |
||
Output |
Control output 1 (NPN) |
100 mA max. (40 V max.) Residual voltage: 1 V max. |
||
Control output 2 |
DPST (N.O.), 250 VAC, |
|||
Disconnection alarm output |
― |
|||
Response |
1 ms |
|||
3 ms | ||||
OFF-delay time |
― |
|||
Temperature characteristics |
0.08%/°C*3 |
|||
Rating |
Power voltage |
110/120/220/240 VAC ±10 %, 50/60 Hz |
||
Power consumption |
5 VA max. |
|||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Weight |
Approx. 390 g |
|||
*1 The EG-547(W) cannot be used in combination with SH-422, 430, 440, 290, 809, 816 and 822. | ||||

Specifications
Model |
EG-547U |
|||
Type |
AC, tolerance setting*1 |
|||
Sensitivity adjustment |
10-turn potentiometer dial |
|||
Function |
Operation mode |
External synchronization, |
||
Operation mode |
External synchronization |
Equipment (both without contacts and with contacts) |
||
Output |
Control output 1 (NPN) |
100 mA max. (40 V max.) Residual voltage: 1 V max. |
||
Control output 2 |
DPST (N.O.), 250 VAC, |
|||
Disconnection alarm output |
― |
|||
Response |
1 ms |
|||
3 ms | ||||
OFF-delay time |
― |
|||
Temperature characteristics |
0.08%/°C*2 |
|||
Rating |
Power voltage |
110/120/220/240 VAC ±10 %, 50/60 Hz |
||
Power consumption |
5 VA max. |
|||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Weight |
Approx. 390 g |
|||
*1 Please contact KEYENCE for information on products that comply with the EMC directive. | ||||

Specifications
Model |
EG-547W*1 |
|||
Type |
AC, tolerance setting*2 |
|||
Sensitivity adjustment |
10-turn potentiometer dial |
|||
Function |
Operation mode |
External synchronization,analog voltageswitch-selectable |
||
Operation mode |
External synchronization |
Equipment (both without contacts and with contacts) |
||
Output |
Control output 1 (NPN) |
100 mA max. (40 V max.) Residual voltage: 1 V max. |
||
Control output 2 |
― |
|||
Disconnection alarm output | ||||
Response |
1 ms |
|||
― | ||||
OFF-delay time | ||||
Temperature characteristics |
0.08%/°C*3 |
|||
Rating |
Power voltage |
24 VDC ±10 %, Ripple (P-P) 10 % or less |
||
Power consumption |
120mA or less |
|||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Weight |
Approx. 390 g |
|||
*1 The EG-547W cannot be used in combination with SH-422, 430, 440, 290, 809, 816 and 822. | ||||

Specifications
Model |
EH-108 |
|||
Type |
Oil-resistant, Shielded, Threaded*1 |
|||
Detectable object |
Ferrous metals (see Characteristics for nonferrous metals) |
|||
Standard target (iron, t=1 mm 0.04") |
10 x 10 mm 0.39" x 0.39" |
|||
Stable detecting range |
0 to 1.5 mm0.06" |
|||
Maximum detecting distance |
2.5 mm0.10" |
|||
Hysteresis |
0.07 mm0.003" |
|||
Repeatability |
0.005 mm0.0002" |
|||
Temperature characteristics |
±10% max. of detecting distance at 23°C 73.4°F, within -10 to +60°C 14 to 140°F |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Ambient temperature |
-10 to +60 °C 14 to 140 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Weight |
Approx. 51 g (including nuts and 3-m 9.8' cable) |
|||
*1 Not designed for immersed use. | ||||

Specifications
Model |
EH-110 |
|||
Type |
Standard , Shielded , Threaded |
|||
Detectable object |
Ferrous metals (see Characteristics for nonferrous metals) |
|||
Standard target (iron, t=1 mm 0.04") |
10 x 10 mm 0.39" x 0.39" |
|||
Stable detecting range |
0 to 2 mm0.08" |
|||
Maximum detecting distance |
5 mm0.20" |
|||
Hysteresis |
0.04 mm0.002" |
|||
Repeatability |
0.005 mm 0.0002" |
|||
Temperature characteristics |
±10% max. of detecting distance at 23°C 73.4°F, within -10 to +60°C 14 to 140°F |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Ambient temperature |
-10 to +60 °C 14 to 140 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Weight |
Approx. 55 g (including nuts and 3-m 9.8' cable) |
|||

Specifications
Model |
EH-110S |
|||
Type |
with stainless steel spiral tube , Shielded , Threaded |
|||
Detectable object |
Ferrous metals (see Characteristics for nonferrous metals) |
|||
Standard target (iron, t=1 mm 0.04") |
10 x 10 mm 0.39" x 0.39" |
|||
Stable detecting range |
0 to 2 mm0.08" |
|||
Maximum detecting distance |
5 mm0.20" |
|||
Hysteresis |
0.04 mm0.002" |
|||
Repeatability |
0.005 mm0.0002" |
|||
Temperature characteristics |
±10% max. of detecting distance at 23°C 73.4°F, within -10 to +60°C 14 to 140°F |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Ambient temperature |
-10 to +60 °C 14 to 140 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Weight |
Approx. 100 g (including nuts and 3-m 9.8' cable) |
|||

Specifications
Model |
EH-114 |
|||
Type |
Standard , Shielded , Threaded |
|||
Detectable object |
Ferrous metals (see Characteristics for nonferrous metals) |
|||
Standard target (iron, t=1 mm 0.04") |
15 x 15 mm 0.59" x 0.59" |
|||
Stable detecting range |
0 to 5 mm0.20" |
|||
Maximum detecting distance |
8 mm0.31" |
|||
Hysteresis |
0.05 mm0.002" |
|||
Repeatability |
0.005 mm 0.0002" |
|||
Temperature characteristics |
±10% max. of detecting distance at 23°C 73.4°F, within -10 to +60°C 14 to 140°F |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Ambient temperature |
-10 to +60 °C 14 to 140 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Weight |
Approx. 62 g (including nuts and 3-m 9.8' cable) |
|||