keyence

6950 products

Showing 1057 - 1080 of 6950 products

Showing 1057 - 1080 of 6950 products
View
Keyence New Stock Image
Keyence CZ-K1P Keyence
Sale price $398.34
In stock, 12 units
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence New Stock Image
Keyence CZ-V1 Keyence
Sale price $438.72
Only 5 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence Stock Image
Keyence CZ-V21 Keyence
Sale price $731.75
Only 6 units left

Specifications

Model

CZ-V21

Output

NPN output

Main unit/expansion unit

Main unit

Response time

8 ms (SUPER) /4 ms (TURBO) /1 ms (FINE) /200 µs (HIGH SPEED)

Control output

NPN open-collector x 4 channels, 40 VDC max., Up to 100 mA for one output, Up to 200 mA in total of 4 outputs, Residual voltage: 1.0 V max.*1

Protection circuit

Reverse-polarity protection, overcurrent protection, surge absorber

External calibration input

No-voltage input, input time: 20 ms or more

External shift input

Timer function

Timer OFF/OFF-delay/ON-delay/One-shot, Timer time: 1 to 1000 ms adjustable (for each bank respectively)

Unit expansion

Up to 3 units (4 units total including the main unit)*2

Rating

Power voltage

24 VDC, Ripple (P-P) 10 % or less

Power consumption

Normal mode: 1.5 W (62.5 mA or less), Eco-mode: 1 W (42.0 mA or less)

Environmental resistance

Ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)*3

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z axis

Material

Housing, cover: Polycarbonate

Weight

Approx. 110 g

*1 20 mA max. when several units are connected.
*2 The FS-V20 Series expansion unit cannot be connected to the CZ-V20 Series main unit. When using a combination of expansion units, connect the CZ-V20 Series expansion unit to the FS-V20 Series main unit. Also, if using multiple expansion units, make sure to connect the CZ-V20 Series to right side of the FS-V20 Series.
*3 When several units are connected, the acceptable ambient temperature varies depending on the conditions given below. To connect several units, be sure to mount them to a DIN rail and to limit the output current to a maximum of 20 mA.
When 1 or 2 units are connected: -10 to +50 °C 14 to 122 °F
When 3 units are connected: -10 to +45 °C 14 to 113 °F

Keyence New Stock Image
Keyence CZ-V21A Keyence
Sale price $317.82
Only 1 unit left

Specifications

Model

CZ-V21A*1

Output

NPN output

Main unit/expansion unit

Main unit

Response time

200 µs (HIGH SPEED) /1 ms (FINE) /4 ms (TURBO) /8 ms (SUPER)

Control output

NPN open-collector x 4 channels, 40 VDC max., Up to 100 mA for one output, Up to 200 mA in total of 4 outputs, Residual voltage: 1.0 V max.*2

Protection circuit

Reverse-polarity protection, overcurrent protection, surge absorber

External tuning input, external bank switch input (C/C + I-mode), external shift input (super I-mode)

Input time: 20 ms min.

Timer function

Timer OFF/OFF-delay/ON-delay/One-shot, Timer time: 1 to 1000 ms adjustable (for each bank respectively)

Unit expansion

Up to 3 units (4 units total including the main unit)

Number of interference prevention units

0 for HIGH SPEED; 2 for FINE/TURBO/SUPER

Rating

Power voltage

24 VDC, Ripple (P-P) 10 % or less

Power consumption

Normal mode: 1.5 W (62.5 mA or less), Eco-mode: 1 W (42.0 mA or less)

Environmental resistance

Ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)*3

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z axis

Material

Housing, cover: Polycarbonate

Accessories

Mounting Fittings

Weight

Approx. 110 g

*1 The expansion unit of the FS-V20 Series cannot be connected to the main unit of the CZ-V20 Series. To connect the FS and CZ Series units, connect the expansion unit of the CZ-V20 Series to
the main unit of the FS-V20 Series.
To connect two or more expansion units, connect the CZ-V20 Series units on the right of the FS-V20 Series units.
*2 20 mA max. when several units are connected.
*3 When several units are connected, the acceptable ambient temperature varies depending on the conditions given below. To connect several units, be sure to mount them to a DIN rail and to limit the output current to a maximum of 20 mA.
When 1 or 2 units are connected: -10 to +50 °C 14 to 122 °F
When 3 units are connected: -10 to +45 °C 14 to 113 °F

Keyence New Stock Image
Keyence CZ-V21AP Keyence
Sale price $329.88
Only 8 units left

Specifications

Model

CZ-V21AP*1

Output

PNP output

Main unit/expansion unit

Main unit

Response time

200 µs (HIGH SPEED) /1 ms (FINE) /4 ms (TURBO) /8 ms (SUPER)

Control output

PNP open-collector x 4 channels, 30 VDC max., Up to 100 mA for one output, Up to 200 mA in total of 4 outputs, Residual voltage: 1.0 V max.*2

Protection circuit

Reverse-polarity protection, overcurrent protection, surge absorber

External tuning input, external bank switch input (C/C + I-mode), external shift input (super I-mode)

Input time: 20 ms min.

Timer function

Timer OFF/OFF-delay/ON-delay/One-shot, Timer time: 1 to 1000 ms adjustable (for each bank respectively)

Unit expansion

Up to 3 units (4 units total including the main unit)

Number of interference prevention units

0 for HIGH SPEED; 2 for FINE/TURBO/SUPER

Rating

Power voltage

24 VDC, Ripple (P-P) 10 % or less

Power consumption

Normal mode: 1.5 W (62.5 mA or less), Eco-mode: 1 W (42.0 mA or less)

Environmental resistance

Ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)*3

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z axis

Material

Housing, cover: Polycarbonate

Accessories

Mounting Fittings

Weight

Approx. 110 g

*1 The expansion unit of the FS-V20 Series cannot be connected to the main unit of the CZ-V20 Series. To connect the FS and CZ Series units, connect the expansion unit of the CZ-V20 Series to
the main unit of the FS-V20 Series.
To connect two or more expansion units, connect the CZ-V20 Series units on the right of the FS-V20 Series units.
*2 20 mA max. when several units are connected.
*3 When several units are connected, the acceptable ambient temperature varies depending on the conditions given below. To connect several units, be sure to mount them to a DIN rail and to limit the output current to a maximum of 20 mA.
When 1 or 2 units are connected: -10 to +50 °C 14 to 122 °F
When 3 units are connected: -10 to +45 °C 14 to 113 °F

Keyence Stock Image
Keyence CZ-V21P Keyence
Sale price $374.06
Only 6 units left

Specifications

Model

CZ-V21P

Output

PNP output

Main unit/expansion unit

Main unit

Response time

8 ms (SUPER) /4 ms (TURBO) /1 ms (FINE) /200 µs (HIGH SPEED)

Control output

PNP open-collector x 4 channels, 30 VDC max., Up to 100 mA for one output, Up to 200 mA in total of 4 outputs, Residual voltage: 1.0 V max.*1

Protection circuit

Reverse-polarity protection, overcurrent protection, surge absorber

External calibration input

No-voltage input, input time: 20 ms or more

External shift input

Timer function

Timer OFF/OFF-delay/ON-delay/One-shot, Timer time: 1 to 1000 ms adjustable (for each bank respectively)

Unit expansion

Up to 3 units (4 units total including the main unit)*2

Rating

Power voltage

24 VDC, Ripple (P-P) 10 % or less

Power consumption

Normal mode: 1.5 W (62.5 mA or less), Eco-mode: 1 W (42.0 mA or less)

Environmental resistance

Ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)*3

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z axis

Material

Housing, cover: Polycarbonate

Weight

Approx. 110 g

*1 20 mA max. when several units are connected.
*2 The FS-V20 Series expansion unit cannot be connected to the CZ-V20 Series main unit. When using a combination of expansion units, connect the CZ-V20 Series expansion unit to the FS-V20 Series main unit. Also, if using multiple expansion units, make sure to connect the CZ-V20 Series to right side of the FS-V20 Series.
*3 When several units are connected, the acceptable ambient temperature varies depending on the conditions given below. To connect several units, be sure to mount them to a DIN rail and to limit the output current to a maximum of 20 mA.
When 1 or 2 units are connected: -10 to +50 °C 14 to 122 °F
When 3 units are connected: -10 to +45 °C 14 to 113 °F

keyence Stock Image
Keyence CZ-V22 Keyence
Sale price $343.14
Only 1 unit left

Specifications

Model

CZ-V22

Output

NPN output

Main unit/expansion unit

Expansionunit (with outputcable)

Response time

8 ms (SUPER) /4 ms (TURBO) /1 ms (FINE) /200 µs (HIGH SPEED)

Control output

NPN open-collector x 4 channels, 40 VDC max., Up to 100 mA for one output, Up to 200 mA in total of 4 outputs, Residual voltage: 1.0 V max.*1

Protection circuit

Reverse-polarity protection, overcurrent protection, surge absorber

External calibration input

No-voltage input, input time: 20 ms or more

External shift input

Timer function

Timer OFF/OFF-delay/ON-delay/One-shot, Timer time: 1 to 1000 ms adjustable (for each bank respectively)

Unit expansion

Up to 3 units (4 units total including the main unit)*2

Rating

Power voltage

24 VDC, Ripple (P-P) 10 % or less

Power consumption

Normal mode: 1.5 W (62.5 mA or less), Eco-mode: 1 W (42.0 mA or less)

Environmental resistance

Ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)*3

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z axis

Material

Housing, cover: Polycarbonate

Weight

Approx. 100 g

*1 20 mA max. when several units are connected.
*2 The FS-V20 Series expansion unit cannot be connected to the CZ-V20 Series main unit. When using a combination of expansion units, connect the CZ-V20 Series expansion unit to the FS-V20 Series main unit. Also, if using multiple expansion units, make sure to connect the CZ-V20 Series to right side of the FS-V20 Series.
*3 When several units are connected, the acceptable ambient temperature varies depending on the conditions given below. To connect several units, be sure to mount them to a DIN rail and to limit the output current to a maximum of 20 mA.
When 1 or 2 units are connected: -10 to +50 °C 14 to 122 °F
When 3 units are connected: -10 to +45 °C 14 to 113 °F

Keyence Stock Image
Keyence CZ-V22A Keyence
Sale price $325.46
Only 7 units left

Specifications

Model

CZ-V22A*1

Output

NPN output

Main unit/expansion unit

Expansion unit

Response time

200 µs (HIGH SPEED) /1 ms (FINE) /4 ms (TURBO) /8 ms (SUPER)

Control output

NPN open-collector x 4 channels, 40 VDC max., Up to 100 mA for one output, Up to 200 mA in total of 4 outputs, Residual voltage: 1.0 V max.*2

Protection circuit

Reverse-polarity protection, overcurrent protection, surge absorber

External tuning input, external bank switch input (C/C + I-mode), external shift input (super I-mode)

Input time: 20 ms min.

Timer function

Timer OFF/OFF-delay/ON-delay/One-shot, Timer time: 1 to 1000 ms adjustable (for each bank respectively)

Unit expansion

Up to 3 units (4 units total including the main unit)

Number of interference prevention units

0 for HIGH SPEED; 2 for FINE/TURBO/SUPER

Rating

Power voltage

24 VDC, Ripple (P-P) 10 % or less

Power consumption

Normal mode: 1.5 W (62.5 mA or less), Eco-mode: 1 W (42.0 mA or less)

Environmental resistance

Ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)*3

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z axis

Material

Housing, cover: Polycarbonate

Accessories

End Unit × 2

Weight

Approx. 100 g

*1 The expansion unit of the FS-V20 Series cannot be connected to the main unit of the CZ-V20 Series. To connect the FS and CZ Series units, connect the expansion unit of the CZ-V20 Series to
the main unit of the FS-V20 Series.
To connect two or more expansion units, connect the CZ-V20 Series units on the right of the FS-V20 Series units.
*2 20 mA max. when several units are connected.
*3 When several units are connected, the acceptable ambient temperature varies depending on the conditions given below. To connect several units, be sure to mount them to a DIN rail and to limit the output current to a maximum of 20 mA.
When 1 or 2 units are connected: -10 to +50 °C 14 to 122 °F
When 3 units are connected: -10 to +45 °C 14 to 113 °F

Keyence New Stock Image
Keyence CZ-V22AP Keyence
Sale price $366.08
Only 9 units left

Specifications

Model

CZ-V22AP*1

Output

PNP output

Main unit/expansion unit

Expansion unit

Response time

200 µs (HIGH SPEED) /1 ms (FINE) /4 ms (TURBO) /8 ms (SUPER)

Control output

PNP open-collector x 4 channels, 30 VDC max., Up to 100 mA for one output, Up to 200 mA in total of 4 outputs, Residual voltage: 1.0 V max.*2

Protection circuit

Reverse-polarity protection, overcurrent protection, surge absorber

External tuning input, external bank switch input (C/C + I-mode), external shift input (super I-mode)

Input time: 20 ms min.

Timer function

Timer OFF/OFF-delay/ON-delay/One-shot, Timer time: 1 to 1000 ms adjustable (for each bank respectively)

Unit expansion

Up to 3 units (4 units total including the main unit)

Number of interference prevention units

0 for HIGH SPEED; 2 for FINE/TURBO/SUPER

Rating

Power voltage

24 VDC, Ripple (P-P) 10 % or less

Power consumption

Normal mode: 1.5 W (62.5 mA or less), Eco-mode: 1 W (42.0 mA or less)

Environmental resistance

Ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)*3

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z axis

Material

Housing, cover: Polycarbonate

Accessories

End Unit × 2

Weight

Approx. 100 g

*1 The expansion unit of the FS-V20 Series cannot be connected to the main unit of the CZ-V20 Series. To connect the FS and CZ Series units, connect the expansion unit of the CZ-V20 Series to
the main unit of the FS-V20 Series.
To connect two or more expansion units, connect the CZ-V20 Series units on the right of the FS-V20 Series units.
*2 20 mA max. when several units are connected.
*3 When several units are connected, the acceptable ambient temperature varies depending on the conditions given below. To connect several units, be sure to mount them to a DIN rail and to limit the output current to a maximum of 20 mA.
When 1 or 2 units are connected: -10 to +50 °C 14 to 122 °F
When 3 units are connected: -10 to +45 °C 14 to 113 °F

Keyence Stock Image
Keyence CZ-V22P Keyence
Sale price $924.30
Only 2 units left

Specifications

Model

CZ-V22P

Output

PNP output

Main unit/expansion unit

Expansionunit (with outputcable)

Response time

8 ms (SUPER) /4 ms (TURBO) /1 ms (FINE) /200 µs (HIGH SPEED)

Control output

PNP open-collector x 4 channels, 30 VDC max., Up to 100 mA for one output, Up to 200 mA in total of 4 outputs, Residual voltage: 1.0 V max.*1

Protection circuit

Reverse-polarity protection, overcurrent protection, surge absorber

External calibration input

No-voltage input, input time: 20 ms or more

External shift input

Timer function

Timer OFF/OFF-delay/ON-delay/One-shot, Timer time: 1 to 1000 ms adjustable (for each bank respectively)

Unit expansion

Up to 3 units (4 units total including the main unit)*2

Rating

Power voltage

24 VDC, Ripple (P-P) 10 % or less

Power consumption

Normal mode: 1.5 W (62.5 mA or less), Eco-mode: 1 W (42.0 mA or less)

Environmental resistance

Ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)*3

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z axis

Material

Housing, cover: Polycarbonate

Weight

Approx. 100 g

*1 20 mA max. when several units are connected.
*2 The FS-V20 Series expansion unit cannot be connected to the CZ-V20 Series main unit. When using a combination of expansion units, connect the CZ-V20 Series expansion unit to the FS-V20 Series main unit. Also, if using multiple expansion units, make sure to connect the CZ-V20 Series to right side of the FS-V20 Series.
*3 When several units are connected, the acceptable ambient temperature varies depending on the conditions given below. To connect several units, be sure to mount them to a DIN rail and to limit the output current to a maximum of 20 mA.
When 1 or 2 units are connected: -10 to +50 °C 14 to 122 °F
When 3 units are connected: -10 to +45 °C 14 to 113 °F

Keyence New Stock Image
Keyence DD-860 Keyence
Sale price $1,380.78
Only 9 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence Stock Image
Keyence DD-960 Keyence
Sale price $1,280.30
Only 2 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Keyence Stock Image
Keyence DH-214R Keyence
Sale price$0.00
Sold Out

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Keyence Stock Image
Keyence DH-220 Keyence
Sale price $1,682.23
Only 5 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Keyence Stock Image
Keyence DH-320 Keyence
Sale price $2,098.01
Only 5 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Keyence New Stock Image
Keyence DL-CL1 Keyence
Sale price $398.34
In stock, 14 units

Specifications

Model

DL-CL1*1

Supported version

Version 2.00, version 1.10 (switchable)

CC-Link specifications

No. of occupied stations

Version 2.00: 1 station x 8, 2 stations x 8, 4 stations x 2 (switchable), version 1.10: 1 station, 2 stations, 4 stations (switchable)

Station type

Remote device station

Transmission speed

156 kbps/625 kbps/2.5 Mbps/5 Mbps/10 Mbps

Station number settings

1 to 64

Power voltage

20 to 30 VDC, including ripple, Ripple (P-P): 10 % max. Class 2 (Supplied via connected sensor amplifier)

Weight

Approx. 80 g

*1 For connecting with sensor, please refer to the user's Manual

Keyence New Stock Image
Keyence DL-DN1 Keyence
Sale price $981.53
Only 9 units left

Specifications

Model

DL-DN1*1

DeviceNet® specifi cations

Network power supply

11 to 25 VDC (supplied from DeviceNet® communication power supply)

Indicator

Network status indicator: 2-color (green/red) LED, Module status indicator: 2-color (green/red) LED,
Sensor communication indicator: 2-color (green/red) LED

Sensor
connection
specifications

Connectable
sensors

Sensor amplifiers with D-bus support*2

Number of
connectable
sensor units

Up to 15 units

DeviceNet® specifi cations

Compliant functions

Remote I/O communication (polling) Explicit messaging

Address setting

0 to 63 (PGM compatible)

Baud rate (automatically switched)

500 kbps/250 kbps/125 kbps

Maximum cable length

500 kbps

thick cable

100 m 328.09' (thick cable)

thin cable

250 kbps

thick cable

250 m 820.21' (thick cable)

thin cable

100 m 328.09' (thick cable)

125 kbps

thick cable

500 m 1640.42' (thick cable)

thin cable

100 m 328.09' (thick cable)

Power voltage

20 to 30 VDC, including ripple, Ripple (P-P): 10 % max. Class 2 (Supplied via connected sensor amplifier)

Power consumption

660 mW or less (at 30 V, 22 mA max.)

Environmental resistance

Pollution degree

2

Ambient temperature

-20 to +55 °C -4 to 131 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Main unit case and dust cover: Polycarbonate, DeviceNet® connector: Polyamide (plug), PUT (socket)

Weight

Approx. 80 g

*1 For connecting with sensor, please refer to the user's Manual
*2 "D-bus" is the name of KEYENCE's wiring-saving system for sensor amplifiers.

Keyence Stock Image
Keyence DL-EC1A Keyence
Sale price $374.06
Only 9 units left

Specifications

Model

DL-EC1A

Ethernet
specifications

Compliant standards

IEEE802.3u (100BASE-TX)

Transmission speed

100 Mbps (100BASE-TX)

Transmission interface

Category 5e or higher STP cable

Distance between
nodes

100 m 3937.01'

Communication port

RJ-45 x 2

EtherCAT
communication
specifications

Compatible functions

Process data object communication (cyclic communication)
Mailbox communication (message communication) CoE compatible
Explicit Device Identification

Conformance test
version

Complies with V2.0.42

Sensor
connection
specifications

Connectable
sensors

Sensor amplifiers with D-bus support*1

Number of
connectable
sensor units

15 units max.*2

Indicator lamps

Power indicator (PWR): Green LED
RUN indicator (RUN): Green LED
ERR indicator (ERR): Red LED
Sensor communication indicator (D-bus): 2-color (green/red) LED
Link/activity indicator: Green LED

Power voltage

20 to 30 VDC, including ripple (p-p) of 10 %
supplied from the connected sensor amplifiers

Power consumption

2,100 mW or less (at 30 V, 70 mA max.)

Environmental resistance

Pollution degree

2

Ambient temperature

-20 to +55 °C -4 to 131 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Main unit: Polycarbonate

Weight

Approx. 70 g (including connectors)

*1 D-bus is the name of KEYENCE's wiring-saving system for sensor amplifiers.
*2 This varies depending on the connected sensor amplifiers.

keyence Stock Image
Keyence DL-EN1 Keyence
Sale price $462.56
Only 6 units left

Specifications

Model

DL-EN1

Ethernet
specifications

Compliant standards

IEEE802.3u (100BASE-TX)

Transmission speed

100Mbps (100BASE-TX)

Transmission interface

STP cable or Category 5 or higher UTP cable (100BASE-TX)

Maximum cable length

100 m (Distance between DL-EN1 and Ethernet switch)

Performance
specifications

Socket communication,
no-protocol commands,
ASCII

TCP socket 1
Port number can be set between 1 and 65535
8500: Reserved for the system
Initial value: 64000

Sensor
connection
specifications

Connectable
sensors

Sensor amplifiers with D-bus support*1

Number of
connectable
sensor units

15 units max*2

Indicator lamps

Link/activity indicator (LINK/ACT): Green LED
Module status indicator (MS): 2-color (green/red) LED
Network status indicator (NS): 2-color (green/red) LED
Sensor communication indicator (D-bus): 2-color (green/red) LED

Power voltage

20 to 30 VDC ±10%, including ripple (p-p)10%
(supplied from the connected sensor amplifiers)

Power consumption

1500 mW or less (at 30 V 50 mA max)

Environmental resistance

Pollution degree

2

Ambient temperature

-20 to +55 °C -4 to 131 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Main unit case: Polycarbonate

Weight

Approx. 70 g

*1 "D-bus" is the name of KEYENCE's wiring-saving system for sensor amplifiers.
*2 Varies with the sensor amplifiers connected.

Keyence New Stock Image
Keyence DL-EP1 Keyence
Sale price $398.34
Only 6 units left

Specifications

Model

DL-EP1*1

Indicator

Link/activity indicator (LINK/ACT): Green LED, Module status indicator (MS): 2-color (green/red) LED,
Network status indicator (NS): 2-color (green/red) LED, Sensor communication indicator (D-bus) 2-color (green/red) LED

Sensor
connection
specifications

Connectable
sensors

Sensor amplifiers with D-bus support*2

Number of
connectable
sensor units

Up to 15 units

EtherNet/IP™specifications

Compliant functions

Cyclic communication (Implicit messaging)Message communication (Explicit messaging)Compatible with UCMM and Class 3

Number of connections

64

EtherNet/IP™ specifications

RPI (Transmission cycle)

0.5 to 10000 ms (0.5 ms unit)

EtherNet/IP™specifications

Tolerable communication bandwidth forcyclic communication

6000pps

EtherNet/IP™ specifications

Conformance test

Compatible with Version A7

Power voltage

20 to 30 VDC, including ripple, Ripple (P-P): 10% max. Class 2 (Supplied via connected sensor amplifier)

Power consumption

1500 mW or less (at 30 V 50 mA max)

Environmental resistance

Pollution degree

2

Ambient temperature

-20 to +55 °C -4 to 131 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Main unit case: Polycarbonate

Weight

Approx. 70g

*1 For connecting with sensor, please refer to the user's Manual
*2 "D-bus" is the name of KEYENCE's wiring-saving system for sensor amplifiers.

Keyence Stock Image
Keyence DL-NS1 Keyence
Sale price $936.00
Only 1 unit left

Specifications

Model

DL-NS1

Cable connector

M12 Male

USB connector

USB TypeA

USB Communication

USB2.0 Full Speed

Interface

USB-COM

OS

Windows 11 Home/Pro/Enterprise (32bit/64bit)
Windows 10 Home/Pro/Enterprise (32bit/64bit)
One OS must be installed.

Control input

The number of input

2

Input type

Voltage input

Maximum rating

26.4V

Minmum ON voltage

DC15V

Maximum OFF current

0.2mA

Control output

The number of output

2

Output type

Photo relay output

Control output current

30VDC 50mA max.per output

Maximum leak current

0.1mA max.

Maximum residual voltage

1V max.

Switch input

Input type

No-voltage input

Supplied voltage

Approx. 5V

Supplied current

10mA max.

Power voltage

USB bus power

Power consumption

100mA max.

Environmental resistance

Ambient temperature

-10 to +50 °C 14 to 122 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Main unit:Polycarbonate(PC)、Cable:PVC

Weight

Approx. 45 g (including the cable)

Keyence Stock Image
Keyence DL-PD1 Keyence
Sale price $834.44
Only 9 units left

Specifications

Model

DL-PD1

Sensor
connection
specifications

Connectable
sensors

Sensor amplifiers with D-bus support*1

Number of
connectable
sensor units

15 units max.*2

PROFIBUS
DP
specifications

Device type

DP-V1 Slave (D-sub 9 pin, Number of the ports: 1)

Communication speed

9.6 kbit/s to 12 Mbit/s

Cable length

9.6 / 19.2 / 45.45 / 93.75 kbit/s : 1200 m
187.5 kbit/s : 1000 m
500 kbit/s : 400 m
1.5 Mbit/s : 200 m
3 / 6 / 12 Mbit/s : 100 m

Power voltage

20 to 30 VDC, including ripple (p-p) 10%
(This voltage is supplied from the connected sensor amplifier.)

Power consumption

1600 mW or less (65 mA max. at 24 V)

Environmental resistance

Ambient temperature

-20 to +55 °C -4 to 131 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

500 m/s2, 3 times in each of the X, Y, and Z directions

Material

Main unit case and dust cover: Polycarbonate PROFIBUS connector: Steel – Nickel plating

Weight

Approx. 65 g

*1 "D-bus" is the name of KEYENCE's wiring-saving system for sensor amplifiers.
*2 Varies with the sensor amplifiers connected.

Keyence New Stock Image
Keyence DL-PN1 Keyence
Sale price $374.06
Only 9 units left

Specifications

Model

DL-PN1

Type

PROFINET Network communication unit

PROFINET
specifications

Conformance class

Conformance Class A

Number of connections

1

Compliant protocol

LLDP, DCP

Update time

2 to 512 ms

Conformance test

V2.2.4

Device type

Data I/O Communication
Record data Communication

GSDML Version

Ver. 2.3

Rating

Power voltage

20 to 30 VDC, including Ripple (P-P) 10 %
(Supplied from the connected sensor amplifier)

Weight

Approx. 70 g (Including the connector)

Keyence Stock Image
Keyence DL-RB1 Keyence
Sale price $946.49
Only 1 unit left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Recently viewed