Specifications
Model |
CL-P150 *1 |
|||
Type |
Sensor head (150 mm・Focused spot type) |
|||
*1 The sensor head and optical unit have been configured as a pair. Specifications can be found on the page relating to the optical unit. | ||||

Specifications
Model |
CL-P150G |
|||
Type |
Optical unit |
|||
Head |
CL-P150 *1 |
|||
Reference distance |
150 mm 5.91" |
|||
Reference measurement range |
Measurement range |
±35 mm ±1.38" |
||
Linearity |
±5.5 μm ±0.000217" *2 |
|||
High precision measurement range |
Measurement range |
±15 mm ±0.59" |
||
Linearity |
±4.5 μm ±0.000177" *2 |
|||
Resolution |
0.1 μm 0.000004" *3 |
|||
Spot diameter |
ø75 μm ø0.0030" |
|||
Laser class |
Optical unit |
Class I |
||
Sampling cycle |
100/200/500/1000 μs (Adjustable 4-stage) |
|||
Environmental resistance |
Enclosure rating |
Head |
IP67 (IEC60529) |
|
Ambient light |
Target surface illuminance: 30000 lux (Incandescent lamp) |
|||
Ambient temperature |
0 to 50°C 32 to 122°F |
|||
Relative humidity |
85% RH or less (no condensation) |
|||
Vibration resistance |
Head |
10 to 57 Hz, double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axes |
||
Optical unit |
10 to 57 Hz, double amplitude 0.3 mm 0.01"; 2 hours each for X, Y, and Z axes |
|||
Shock resistance |
15 G, 6 ms |
|||
Temperature characteristic |
Head |
0.005% of F.S./°C |
||
Optical unit |
0.015% of F.S./°C |
|||
Material |
Head |
Front: SUS, Rear: Aluminum |
||
Optical unit |
Polycarbonate |
|||
Weight |
Head |
Approx. 380 g 13.41 oz |
||
Optical unit |
Approx. 1600 g 3.53 lb |
|||
*1 Sensor head and optical unit are a matched pair. Not cross compatible. | ||||

Specifications
Model |
CL-P150N |
|||
Type |
Optical unit |
|||
Head |
CL-P150 *1 |
|||
Reference distance |
150 mm 5.91" |
|||
Reference measurement range |
Measurement range |
±35 mm ±1.38" |
||
Linearity |
±5.65 μm ±0.000222" *2 |
|||
High precision measurement range |
Measurement range |
±15 mm ±0.59" |
||
Linearity |
±4.65 μm ±0.000183" *2 |
|||
Resolution |
0.25 μm 0.000010" |
|||
Spot diameter |
ø75 μm ø0.0030" |
|||
Laser class |
Optical unit |
Class I |
||
Sampling cycle |
100/200/500/1000 μs (Adjustable 4-stage) |
|||
Environmental resistance |
Enclosure rating |
Head |
IP67 (IEC60529) |
|
Ambient light |
Target surface illuminance: 30000 lux (Incandescent lamp) |
|||
Ambient temperature |
0 to 50°C 32 to 122°F |
|||
Relative humidity |
85% RH or less (no condensation) |
|||
Vibration resistance |
Head |
10 to 57 Hz, double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axes |
||
Optical unit |
10 to 57 Hz, double amplitude 0.3 mm 0.01"; 2 hours each for X, Y, and Z axes |
|||
Shock resistance |
15 G, 6 ms |
|||
Temperature characteristic |
Head |
0.005% of F.S./°C |
||
Optical unit |
0.015% of F.S./°C |
|||
Material |
Head |
Front: SUS, Rear: Aluminum |
||
Optical unit |
Polycarbonate |
|||
Weight |
Head |
Approx. 380 g 13.41 oz |
||
Optical unit |
Approx. 1600 g 3.53 lb |
|||
*1 Sensor head and optical unit are a matched pair. Not cross compatible. | ||||

Specifications
Model |
CL-PT010 *1 |
|||
Type |
Sensor head (Profile Measurement Model) |
|||
*1 The sensor head and optical unit have been configured as a pair. Specifications can be found on the page relating to the optical unit. | ||||

Specifications
Model |
CL-PT010G |
|||
Type |
Optical unit |
|||
Head |
CL-PT010 *1 |
|||
Reference distance |
10 mm 0.39" |
|||
Reference measurement range |
Measurement range |
±0.3 mm ±0.01" |
||
Linearity |
±0.11 μm ±0.000004" *2 |
|||
High precision measurement range |
Measurement range |
±0.15 mm ±0.01" |
||
Linearity |
±0.09 μm ±0.000004" *3 |
|||
Resolution |
0.001 μm *4 |
|||
Spot diameter |
ø3.5 μm ø0.000138" |
|||
Laser class |
Optical unit |
Class I |
||
Sampling cycle |
100/200/500/1000 μs (Adjustable 4-stage) |
|||
Environmental resistance |
Enclosure rating |
Head |
IP64 (IEC60529) |
|
Ambient light |
Target surface illuminance: 30000 lux (Incandescent lamp) |
|||
Operating ambient temperature |
Head |
0 to 50°C 32 to 122°F |
||
Optical unit | ||||
Relative humidity |
85% RH or less (no condensation) |
|||
Vibration resistance |
Head |
10 to 57 Hz, double amplitude 0.45 mm 0.02" 2 hours each for X, Y, and Z axes |
||
Optical unit |
10 to 57 Hz, double amplitude 0.3 mm 0.01"; 2 hours each for X, Y, and Z axes |
|||
Shock resistance |
15 G, 6 ms |
|||
Vacuum |
None |
|||
Explosion-proof |
performance |
Head |
||
Optical unit | ||||
Zone/Division |
Head |
|||
Optical unit | ||||
Ambient temperature |
Head |
|||
Optical unit | ||||
Certification number | ||||
Temperature characteristic |
Head |
0.1% of F.S./°C *5 |
||
Optical unit |
0.015% of F.S./°C |
|||
Material |
Head |
Front: SUS, Rear: Aluminum |
||
Optical unit |
Polycarbonate |
|||
Weight |
Head |
Approx. 1100 g 2.43 lb |
||
Optical unit |
Approx. 1600 g 3.53 lb |
|||
*1 Sensor head and optical unit are a matched pair. Not cross compatible. | ||||

Specifications
Model |
CL-PT010N |
|||
Type |
Optical unit |
|||
Head |
CL-PT010 *1 |
|||
Reference distance |
10 mm 0.39" |
|||
Reference measurement range |
Measurement range |
±0.3 mm ±0.01" |
||
Linearity |
±0.22 μm ±0.000009" *2 |
|||
High precision measurement range |
Measurement range |
±0.15 mm ±0.01" |
||
Linearity |
±0.2 μm ±0.000008" *2 |
|||
Resolution |
0.25 μm 0.000010" *3 |
|||
Spot diameter |
ø3.5 μm ø0.000138" |
|||
Laser class |
Optical unit |
Class I |
||
Sampling cycle |
100/200/500/1000 μs (Adjustable 4-stage) |
|||
Environmental resistance |
Enclosure rating |
Head |
IP64 (IEC60529) |
|
Ambient light |
Target surface illuminance: 30000 lux (Incandescent lamp) |
|||
Operating ambient temperature |
Head |
0 to 50°C 32 to 122°F |
||
Optical unit | ||||
Relative humidity |
85% RH or less (no condensation) |
|||
Vibration resistance |
Head |
10 to 57 Hz, double amplitude 0.45 mm 0.02" 2 hours each for X, Y, and Z axes |
||
Optical unit |
10 to 57 Hz, double amplitude 0.3 mm 0.01"; 2 hours each for X, Y, and Z axes |
|||
Shock resistance |
15 G, 6 ms |
|||
Vacuum |
None |
|||
Explosion-proof |
performance |
Head |
||
Optical unit | ||||
Zone/Division |
Head |
|||
Optical unit | ||||
Ambient temperature |
Head |
|||
Optical unit | ||||
Certification number | ||||
Temperature characteristic |
Head |
0.1% of F.S./°C *4 |
||
Optical unit |
0.015% of F.S./°C |
|||
Material |
Head |
Front: SUS, Rear: Aluminum |
||
Optical unit |
Polycarbonate |
|||
Weight |
Head |
Approx. 1100 g 2.43 lb |
||
Optical unit |
Approx. 1600 g 3.53 lb |
|||
*1 Sensor head and optical unit are a matched pair. Not cross compatible. | ||||

Specifications
Model |
CL-S015 *1 |
|||
Type |
Sensor head (Ultra-high-accuracy 15 mm model) |
|||
*1 The sensor head and optical unit have been configured as a pair. Specifications can be found on the page relating to the optical unit. | ||||

Specifications
Model |
CL-S015EX *1 |
|||
Type |
Sensor head (Explosion-proof 15 mm model) |
|||
*1 The sensor head and optical unit have been configured as a pair. Specifications can be found on the page relating to the optical unit. | ||||

Specifications
Model |
CL-S015EXG |
|||
Type |
Optical unit |
|||
Head |
CL-S015EX *1 |
|||
Reference distance |
15 mm 0.59" |
|||
Reference measurement range |
Measurement range |
±1.0 mm ±0.04" |
||
Linearity |
±0.2 μm ±0.000008" *2 |
|||
High precision measurement range |
Measurement range |
-0.2 mm/-1.0 mm -0.01/-0.04" |
||
Linearity |
±0.1 μm ±0.000004" *2 |
|||
Resolution |
0.003 μm *3 |
|||
Spot diameter |
ø10 μm ø0.0004" |
|||
Laser class |
Optical unit |
Class I |
||
Sampling cycle |
100/200/500/1000 μs (Adjustable 4-stage) |
|||
Environmental resistance |
Enclosure rating |
Head |
IP50 |
|
Ambient light |
Target surface illuminance: 30000 lux (Incandescent lamp) |
|||
Operating ambient temperature |
Head |
-20 to 70°C -4 to 158°F |
||
Optical unit |
0 to 50°C 32 to 122°F |
|||
Relative humidity |
85% RH or less (no condensation) |
|||
Vibration resistance |
Head |
10 to 57 Hz, double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axes |
||
Optical unit |
10 to 57 Hz, double amplitude 0.3 mm 0.01"; 2 hours each for X, Y, and Z axes |
|||
Shock resistance |
15 G, 6 ms |
|||
Vacuum |
Vacuum environments |
|||
Explosion-proof |
performance |
Head |
IECEx: Ex op is IIC T6 Ga |
|
Optical unit |
IECEx: Ex op is IIC T6 Ga |
|||
Zone/Division |
Head |
IECEx: Zone 0 |
||
Optical unit |
Do not install in a hazardous location (associated equipment) |
|||
Ambient temperature |
Head |
-20°C ≤ Ta ≤ 70°C -4°F ≤ Ta ≤ 158°F |
||
Optical unit |
0°C ≤ Ta ≤ 50°C 32°F ≤ Ta ≤ 122°F |
|||
Certification number |
IECEx: IECEx CSAE 23.0033X |
|||
Temperature characteristic |
Head |
0.005% of F.S./°C *4 |
||
Optical unit |
0.015% of F.S./°C |
|||
Material |
Head |
SUS303/304 |
||
Optical unit |
Polycarbonate |
|||
Weight |
Head |
Approx. 350 g 12.36 oz |
||
Optical unit |
Approx. 1600 g 3.53 lb |
|||
*1 Sensor head and optical unit are a matched pair. Not cross compatible. | ||||

Specifications
Model |
CL-S015EXN |
|||
Type |
Optical unit |
|||
Head |
CL-S015EX *1 |
|||
Reference distance |
15 mm 0.59" |
|||
Reference measurement range |
Measurement range |
±1.0 mm ±0.04" |
||
Linearity |
±0.35 μm ±0.000014" *2 |
|||
High precision measurement range |
Measurement range |
-0.2 mm/-1.0 mm -0.01/-0.04" |
||
Linearity |
±0.25 μm ±0.000010" *2 |
|||
Resolution |
0.25 μm 0.000010" *3 |
|||
Spot diameter |
ø10 μm ø0.0004" |
|||
Laser class |
Optical unit |
Class I |
||
Sampling cycle |
100/200/500/1000 μs (Adjustable 4-stage) |
|||
Environmental resistance |
Enclosure rating |
Head |
IP50 |
|
Ambient light |
Target surface illuminance: 30000 lux (Incandescent lamp) |
|||
Operating ambient temperature |
Head |
-20 to 70°C -4 to 158°F |
||
Optical unit |
0 to 50°C 32 to 122°F |
|||
Relative humidity |
85% RH or less (no condensation) |
|||
Vibration resistance |
Head |
10 to 57 Hz, double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axes |
||
Optical unit |
10 to 57 Hz, double amplitude 0.3 mm 0.01"; 2 hours each for X, Y, and Z axes |
|||
Shock resistance |
15 G, 6 ms |
|||
Vacuum |
Vacuum environments |
|||
Explosion-proof |
performance |
Head |
IECEx: Ex op is IIC T6 Ga |
|
Optical unit |
IECEx: [Ex op is IIC T6 Ga] |
|||
Zone/Division |
Head |
IECEx: Zone 0 |
||
Optical unit |
Do not install in a hazardous location (associated equipment) |
|||
Ambient temperature |
Head |
-20°C ≤ Ta ≤ 70°C -4°F ≤ Ta ≤ 158°F |
||
Optical unit |
0°C ≤ Ta ≤ 50°C 32°F ≤ Ta ≤ 122°F |
|||
Certification number |
IECEx: IECEx CSAE 23.0033X |
|||
Temperature characteristic |
Head |
0.005% of F.S./°C *4 |
||
Optical unit |
0.015% of F.S./°C |
|||
Material |
Head |
SUS303/304 |
||
Optical unit |
Polycarbonate |
|||
Weight |
Head |
Approx. 350 g 12.36 oz |
||
Optical unit |
Approx. 1600 g 3.53 lb |
|||
*1 Sensor head and optical unit are a matched pair. Not cross compatible. | ||||

Specifications
Model |
CL-S015G |
|||
Type |
Optical unit |
|||
Head |
CL-S015 *1 |
|||
Reference distance |
15 mm 0.59" |
|||
Reference measurement range |
Measurement range |
±1.0 mm ±0.04" |
||
Linearity |
±0.2 μm ±0.000008" *2 |
|||
High precision measurement range |
Measurement range |
-0.2 mm/-1.0 mm -0.01/-0.04" |
||
Linearity |
±0.1 μm ±0.000004" *2 |
|||
Resolution |
0.003 μm *3 |
|||
Spot diameter |
ø10 μm ø0.0004" |
|||
Laser class |
Optical unit |
Class I |
||
Sampling cycle |
100/200/500/1000 μs (Adjustable 4-stage) |
|||
Environmental resistance |
Enclosure rating |
Head |
IP50 |
|
Ambient light |
Target surface illuminance: 30000 lux (Incandescent lamp) |
|||
Operating ambient temperature |
Head |
-20 to 70°C -4 to 158°F |
||
Optical unit |
0 to 50°C 32 to 122°F |
|||
Relative humidity |
85% RH or less (no condensation) |
|||
Vibration resistance |
Head |
10 to 57 Hz, double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axes |
||
Optical unit |
10 to 57 Hz, double amplitude 0.3 mm 0.01"; 2 hours each for X, Y, and Z axes |
|||
Shock resistance |
15 G, 6 ms |
|||
Vacuum |
Vacuum environments |
|||
Explosion-proof |
performance |
Head |
None |
|
Optical unit | ||||
Zone/Division |
Head |
|||
Optical unit | ||||
Ambient temperature |
Head |
|||
Optical unit | ||||
Certification number | ||||
Temperature characteristic |
Head |
0.005% of F.S./°C *4 |
||
Optical unit |
0.015% of F.S./°C |
|||
Material |
Head |
SUS303/304 |
||
Optical unit |
Polycarbonate |
|||
Weight |
Head |
Approx. 350 g 12.36 oz |
||
Optical unit |
Approx. 1600 g 3.53 lb |
|||
*1 Sensor head and optical unit are a matched pair. Not cross compatible. | ||||

Specifications
Model |
CL-S015N |
|||
Type |
Optical unit |
|||
Head |
CL-S015 *1 |
|||
Reference distance |
15 mm 0.59" |
|||
Reference measurement range |
Measurement range |
±1.0 mm ±0.04" |
||
Linearity |
±0.35 μm ±0.000014" *2 |
|||
High precision measurement range |
Measurement range |
-0.2 mm/-1.0 mm -0.01/-0.04" |
||
Linearity |
±0.25 μm ±0.000010" *2 |
|||
Resolution |
0.25 μm 0.000010" *3 |
|||
Spot diameter |
ø10 μm ø0.0004" |
|||
Laser class |
Optical unit |
Class I |
||
Sampling cycle |
100/200/500/1000 μs (Adjustable 4-stage) |
|||
Environmental resistance |
Enclosure rating |
Head |
IP50 |
|
Ambient light |
Target surface illuminance: 30000 lux (Incandescent lamp) |
|||
Operating ambient temperature |
Head |
-20 to 70°C -4 to 158°F |
||
Optical unit |
0 to 50°C 32 to 122°F |
|||
Relative humidity |
85% RH or less (no condensation) |
|||
Vibration resistance |
Head |
10 to 57 Hz, double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axes |
||
Optical unit |
10 to 57 Hz, double amplitude 0.3 mm 0.01"; 2 hours each for X, Y, and Z axes |
|||
Shock resistance |
15 G, 6 ms |
|||
Vacuum |
Vacuum environments |
|||
Explosion-proof |
performance |
Head |
None |
|
Optical unit | ||||
Zone/Division |
Head |
|||
Optical unit | ||||
Ambient temperature |
Head |
|||
Optical unit | ||||
Certification number | ||||
Temperature characteristic |
Head |
0.005% of F.S./°C *4 |
||
Optical unit |
0.015% of F.S./°C |
|||
Material |
Head |
SUS303/304 |
||
Optical unit |
Polycarbonate |
|||
Weight |
Head |
Approx. 350 g 12.36 oz |
||
Optical unit |
Approx. 1600 g 3.53 lb |
|||
*1 Sensor head and optical unit are a matched pair. Not cross compatible. | ||||

Specifications
Model |
CL-V020 *1 |
|||
Type |
Sensor head (20 mm vacuum and heatresistant model) |
|||
*1 The sensor head and optical unit have been configured as a pair. Specifications can be found on the page relating to the optical unit. | ||||

Specifications
Model |
CL-V020G |
|||
Type |
Optical unit |
|||
Head |
CL-V020 *1 |
|||
Reference distance |
20 mm 0.79" |
|||
Reference measurement range |
Measurement range |
±1.3 mm ±0.05" |
||
Linearity |
±0.3 μm ±0.000012" *2 |
|||
High precision measurement range |
Measurement range |
±0.5 mm ±0.02" |
||
Linearity |
±0.23 μm ±0.000009" *2 |
|||
Resolution |
0.01 μm *3 |
|||
Spot diameter |
ø20 μm ø0.0008" |
|||
Laser class |
Optical unit |
Class I |
||
Sampling cycle |
100/200/500/1000 μs (Adjustable 4-stage) |
|||
Environmental resistance |
Enclosure rating |
Head |
IP40 degassed structure for vacuum environments *4 |
|
Ambient light |
Target surface illuminance: 30000 lux (Incandescent lamp) |
|||
Operating ambient temperature |
Head |
-20 to 200°C -4 to 392°F |
||
Optical unit |
0 to 50°C 32 to 122°F |
|||
Relative humidity |
85% RH or less (no condensation) |
|||
Vibration resistance |
Head |
10 to 57 Hz, double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axes |
||
Optical unit |
10 to 57 Hz, double amplitude 0.3 mm 0.01"; 2 hours each for X, Y, and Z axes |
|||
Shock resistance |
15 G, 6 ms |
|||
Vacuum |
Ultra-high-vacuum environments *5 |
|||
Explosion-proof |
performance |
Head |
None |
|
Optical unit | ||||
Zone/Division |
Head |
|||
Optical unit | ||||
Ambient temperature |
Head |
|||
Optical unit | ||||
Certification number | ||||
Temperature characteristic |
Head |
0.013% of F.S./°C *6 |
||
Optical unit |
0.015% of F.S./°C |
|||
Material |
Head |
SUS304 |
||
Optical unit |
Polycarbonate |
|||
Weight |
Head |
Approx. 100 g 3.53 oz |
||
Optical unit |
Approx. 1600 g 3.53 lb |
|||
*1 Sensor head and optical unit are a matched pair. Not cross compatible. | ||||

Specifications
Model |
CL-V020N |
|||
Type |
Optical unit |
|||
Head |
CL-V020 *1 |
|||
Reference distance |
20 mm 0.79" |
|||
Reference measurement range |
Measurement range |
±1.3 mm ±0.05" |
||
Linearity |
±0.45 μm ±0.000018" *2 |
|||
High precision measurement range |
Measurement range |
±0.5 mm ±0.02" |
||
Linearity |
±0.38 μm ±0.000015" *2 |
|||
Resolution |
0.25 μm 0.000010" *3 |
|||
Spot diameter |
ø20 μm ø0.0008" |
|||
Laser class |
Optical unit |
Class I |
||
Sampling cycle |
100/200/500/1000 μs (Adjustable 4-stage) |
|||
Environmental resistance |
Enclosure rating |
Head |
IP40 degassed structure for vacuum environments *4 |
|
Ambient light |
Target surface illuminance: 30000 lux (Incandescent lamp) |
|||
Operating ambient temperature |
Head |
-20 to 200°C -4 to 392°F |
||
Optical unit |
0 to 50°C 32 to 122°F |
|||
Relative humidity |
85% RH or less (no condensation) |
|||
Vibration resistance |
Head |
10 to 57 Hz, double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axes |
||
Optical unit |
10 to 57 Hz, double amplitude 0.3 mm 0.01"; 2 hours each for X, Y, and Z axes |
|||
Shock resistance |
15 G, 6 ms |
|||
Vacuum |
Ultra-high-vacuum environments *5 |
|||
Explosion-proof |
performance |
Head |
None |
|
Optical unit | ||||
Zone/Division |
Head |
|||
Optical unit | ||||
Ambient temperature |
Head |
|||
Optical unit | ||||
Certification number | ||||
Temperature characteristic |
Head |
0.013% of F.S./°C *6 |
||
Optical unit |
0.015% of F.S./°C |
|||
Material |
Head |
SUS304 |
||
Optical unit |
Polycarbonate |
|||
Weight |
Head |
Approx. 100 g 3.53 oz |
||
Optical unit |
Approx. 1600 g 3.53 lb |
|||
*1 Sensor head and optical unit are a matched pair. Not cross compatible. | ||||

Specifications
Model |
CL-V050 *1 |
|||
Type |
Sensor head (50 mm vacuum and heatresistant model) |
|||
*1 The sensor head and optical unit have been configured as a pair. Specifications can be found on the page relating to the optical unit. | ||||

Specifications
Model |
CL-V050G |
|||
Type |
Optical unit |
|||
Head |
CL-V050 *1 |
|||
Reference distance |
50 mm1.97" |
|||
Reference measurement range |
Measurement range |
±4 mm ±0.16" |
||
Linearity |
±1.25 μm ±0.000049" *2 |
|||
High precision measurement range |
Measurement range |
±1.6 mm ±0.06" |
||
Linearity |
±1.15 μm ±0.000045" *2 |
|||
Resolution |
0.03 μm 0.000001" *3 |
|||
Spot diameter |
ø40 μm ø0.0016" |
|||
Laser class |
Optical unit |
Class I |
||
Sampling cycle |
100/200/500/1000 μs (Adjustable 4-stage) |
|||
Environmental resistance |
Enclosure rating |
Head |
IP40 degassed structure for vacuum environments *4 |
|
Ambient light |
Target surface illuminance: 30000 lux (Incandescent lamp) |
|||
Operating ambient temperature |
Head |
-20 to 200°C -4 to 392°F |
||
Optical unit |
0 to 50°C 32 to 122°F |
|||
Relative humidity |
85% RH or less (no condensation) |
|||
Vibration resistance |
Head |
10 to 57 Hz, double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axes |
||
Optical unit |
10 to 57 Hz, double amplitude 0.3 mm 0.01"; 2 hours each for X, Y, and Z axes |
|||
Shock resistance |
15 G, 6 ms |
|||
Vacuum |
Ultra-high-vacuum environments *5 |
|||
Explosion-proof |
performance |
Head |
None |
|
Optical unit | ||||
Zone/Division |
Head |
|||
Optical unit | ||||
Ambient temperature |
Head |
|||
Optical unit | ||||
Certification number | ||||
Temperature characteristic |
Head |
0.015% of F.S./°C *6 |
||
Optical unit |
0.015% of F.S./°C |
|||
Material |
Head |
SUS304 |
||
Optical unit |
Polycarbonate |
|||
Weight |
Head |
Approx. 100 g 3.53 oz |
||
Optical unit |
Approx. 1600 g 3.53 lb |
|||
*1 Sensor head and optical unit are a matched pair. Not cross compatible. | ||||

Specifications
Model |
CL-V050N |
|||
Type |
Optical unit |
|||
Head |
CL-V050 *1 |
|||
Reference distance |
50 mm1.97" |
|||
Reference measurement range |
Measurement range |
±4 mm ±0.16" |
||
Linearity |
±1.4 μm ±0.000055" *2 |
|||
High precision measurement range |
Measurement range |
±1.6 mm ±0.06" |
||
Linearity |
±1.3 μm ±0.000051" *2 |
|||
Resolution |
0.25 μm 0.000010" *3 |
|||
Spot diameter |
ø40 μm ø0.0016" |
|||
Laser class |
Optical unit |
Class I |
||
Sampling cycle |
100/200/500/1000 μs (Adjustable 4-stage) |
|||
Environmental resistance |
Enclosure rating |
Head |
IP40 degassed structure for vacuum environments *4 |
|
Ambient light |
Target surface illuminance: 30000 lux (Incandescent lamp) |
|||
Operating ambient temperature |
Head |
-20 to 200°C -4 to 392°F |
||
Optical unit |
0 to 50°C 32 to 122°F |
|||
Relative humidity |
85% RH or less (no condensation) |
|||
Vibration resistance |
Head |
10 to 57 Hz, double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axes |
||
Optical unit |
10 to 57 Hz, double amplitude 0.3 mm 0.01"; 2 hours each for X, Y, and Z axes |
|||
Shock resistance |
15 G, 6 ms |
|||
Vacuum |
Ultra-high-vacuum environments *5 |
|||
Explosion-proof |
performance |
Head |
None |
|
Optical unit | ||||
Zone/Division |
Head |
|||
Optical unit | ||||
Ambient temperature |
Head |
|||
Optical unit | ||||
Certification number | ||||
Temperature characteristic |
Head |
0.015% of F.S./°C *6 |
||
Optical unit |
0.015% of F.S./°C |
|||
Material |
Head |
SUS304 |
||
Optical unit |
Polycarbonate |
|||
Weight |
Head |
Approx. 100 g 3.53 oz |
||
Optical unit |
Approx. 1600 g 3.53 lb |
|||
*1 Sensor head and optical unit are a matched pair. Not cross compatible. | ||||

Specifications
Model |
CU-21A |
|||
Type |
Standard |
|||
External calibration input signal |
Connection sensor |
NPN open-collector output type or type with output with contacts (signal input and synchronization input) |
||
Input |
No. of inputs |
2 |
||
Minimum input time |
5 ms *1 |
|||
Input system |
Transistor (via NPN output device), contact (via limit switch/microswitch, etc.) |
|||
Control output |
Relay output: 1c, 250 VAC, 2 A (resistive load) |
|||
Timer |
― |
|||
Functions |
AND logic |
|||
Operation mode |
Standard, synchronous |
|||
Control output |
Relay contact |
250 VAC 2A SPDT (1c) (resistive load) |
||
Transistor |
―*2 |
|||
DC output |
12 VDC ±10%, 200 mA max. |
|||
Rating |
Power voltage |
100 to 240 VAC ±10 %, 50/60 Hz |
||
Power consumption |
7 VA max. |
|||
Environmental resistance |
Ambient temperature |
-10 to +50 °C 14 to 122 °F (No freezing) |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Weight |
Approx. 105 g |
|||
*1 Required off time: 15 ms minimum. | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
CU-21TA |
|||
Type |
Multi-functional |
|||
External calibration input signal |
Connection sensor |
NPN open-collector output type or type with output with contacts (signal input and synchronization input) |
||
Input |
No. of inputs |
2 |
||
Minimum input time |
0.5 ms *1 |
|||
Input system |
Transistor (via NPN output device), contact (via limit switch/microswitch, etc.) |
|||
Control output |
Relay output: 1c, 250 VAC, 2 A (resistive load) |
|||
Timer |
ON-delay, OFF-delay, One-shot, timer OFF (selectable), 0 .05 to 1 s/0.5 to 10 s (selectable) |
|||
Functions |
Input signal inversion, edge sync. / level sync. selectable, AND logic |
|||
Operation mode |
Timer, standard, synchronous |
|||
Control output |
Relay contact |
250 VAC 2A SPDT (1c) (resistive load) |
||
Transistor |
NPN: 100 mA (40 VDC) max. *2*3 |
|||
DC output |
12 VDC ±10%, 200 mA max. |
|||
Rating |
Power voltage |
100 to 240 VAC ±10 %, 50/60 Hz |
||
Power consumption |
7 VA max. |
|||
Environmental resistance |
Ambient temperature |
-10 to +50 °C 14 to 122 °F (No freezing) |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Accessories |
Plastic screwdriver |
|||
Weight |
Approx. 120 g |
|||
*1 Required off time: 1.5 ms minimum. | ||||



Specifications
Model |
CV-035C |
|||
Type |
Camera |
|||
Image element |
1/3 -inch color CCD image receiving element, 2 x high-speed reading using square-pixel, 350,000 pixels |
|||
Valid pixel count |
320,000 pixels 656 (H) x 492 (V) *1 |
|||
Pixel transfer frequency |
24.5MHz |
|||
Scanning system |
Progressive (16 ms) |
|||
Transfer system |
Digital serial transfer |
|||
Electronic shutter |
1/15, 1/30, 1/60, 1/120, 1/240, 1/500, 1/1000, 1/2000, 1/5000, 1/10000, 1/20000, 0.05 msec to 9000 msec can be set with numeric values. |
|||
Lens mount |
C-mount |
|||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Weight |
Approx. 100 g (not including lens) |
|||
*1 In 310,000-pixel mode, 310,000 pixels (640 x 480) serve as the processing area. In 240,000-pixel mode, 240,000 pixels (512 x 480) serve as the processing area. | ||||