keyence

6950 products

Showing 5809 - 5832 of 6950 products

Showing 5809 - 5832 of 6950 products
View
keyence Stock Image
Keyence SJ-M070C Keyence
Sale price$0.00
Sold Out

Specifications

Model

SJ-M070C

Type

Head

Voltage application method

Pulse AC method

Applied voltage

±5.5 kV

Rated output voltage

±6 kV

Ion balance control method

I.C.C. method

Ion balance

±30 V*1

Supply pressure range

0.2 MPa max.

Control input

Static elimination stop input

Non-voltage input

Control output

Alarm output

NPN open-collector, 100 mA max. (40 V max.)

Ion level alarm output

Condition alarm output

Effective length

324 mm 12.76"*2

Total length

380 mm 14.96"*3

Rating

Power voltage

24 VDC ±10%

Current consumption

450 mA max.

Environmental resistance

Ambient temperature

0 to +40°C 32 to +104°F

Relative humidity

35 to 65%RH (no condensation)

Weight

Approx. 720 g

*1 Measured under the following conditions:
[SJ-M030G/M070G]
Air purge: 3 NL/min per electrode
Down flow: 0.3 m/s 0.98 ft/s
Operating distance: 50 mm 1.97"(50 Hz), 600 mm 23.62" (8 Hz), 1500 mm 59.06"(1 Hz)
[SJ-M030C/M070C]
Air purge: None
Down flow: 0.3 m/s 0.98 ft/s
Operating distance: 50 mm 1.97"(50 Hz), 600 mm 23.62" (8 Hz), 1500 mm 59.06"(1 Hz)
*2 Effective length indicates static elimination range at 50 mm 1.97" operating distance.
*3 Overall length includes mounting brackets.

keyence Stock Image
Keyence SJ-M070G Keyence
Sale price $5,204.30
Only 4 units left

Specifications

Model

SJ-M070G

Type

Head

Voltage application method

Pulse AC method

Applied voltage

±5.5 kV

Rated output voltage

±6 kV

Ion balance control method

I.C.C. method

Ion balance

±30 V*1

Supply pressure range

0.2 MPa max.

Control input

Static elimination stop input

Non-voltage input

Control output

Alarm output

NPN open-collector, 100 mA max. (40 V max.)

Ion level alarm output

Condition alarm output

Effective length

324 mm 12.76"*2

Total length

380 mm 14.96"*3

Rating

Power voltage

24 VDC ±10%

Current consumption

450 mA max.

Environmental resistance

Ambient temperature

0 to +40°C 32 to +104°F

Relative humidity

35 to 65%RH (no condensation)

Weight

Approx. 720 g

*1 Measured under the following conditions:
[SJ-M030G/M070G]
Air purge: 3 NL/min per electrode
Down flow: 0.3 m/s 0.98 ft/s
Operating distance: 50 mm 1.97"(50 Hz), 600 mm 23.62" (8 Hz), 1500 mm 59.06"(1 Hz)
[SJ-M030C/M070C]
Air purge: None
Down flow: 0.3 m/s 0.98 ft/s
Operating distance: 50 mm 1.97"(50 Hz), 600 mm 23.62" (8 Hz), 1500 mm 59.06"(1 Hz)
*2 Effective length indicates static elimination range at 50 mm 1.97" operating distance.
*3 Overall length includes mounting brackets.

keyence Stock Image
Keyence SJ-M071C Keyence
Sale price$0.00
Sold Out

Specifications

Model

SJ-M071C

Type

Head

Voltage application method

Pulse AC method

Applied voltage

±5.5 kV

Rated output voltage

±6 kV

Ion balance control method

I.C.C. method

Ion balance

±30 V*1

Control input

Static elimination stop input

Non-voltage input

Control output

Alarm output

NPN open collector 100 mA (40 V or less)

Ion level alarm output

Condition alarm output

Air purge supplied pressure

0.2 MPa or less

Effective length

324 mm 12.756"*2

Total length

380 mm 14.961"*3

Rating

Power voltage

24 VDC ±10 %

Current consumption

450 mA or less

Environmental resistance

Ambient temperature

0 to +40 °C 32 to 104 °F

Relative humidity

35 to 65 % RH (No condensation)

Weight

Approx. 720 g

*1 Operating distance: 50 mm 1.96" (50 Hz), 600 mm 23.62" (8 Hz), 1,500 mm 59.05" (1 Hz). Downward air flow: 0.3 m/s. Air purge: None
*2 Elective length indicates the static elimination rangeat 50 mm operating distance.
*3 The overall length includes mounting brackets.

keyence Stock Image
Keyence SJ-M071G Keyence
Sale price $320.00
Only 1 unit left

Specifications

Model

SJ-M071G

Type

Head

Voltage application method

Pulse AC method

Applied voltage

±5.5 kV

Rated output voltage

±6 kV

Ion balance control method

I.C.C. method

Ion balance

±30 V*1

Control input

Static elimination stop input

Non-voltage input

Control output

Alarm output

NPN open collector 100 mA (40 V or less)

Ion level alarm output

Condition alarm output

Air purge supplied pressure

0.2 MPa or less

Effective length

324 mm 12.756"*2

Total length

380 mm 14.961"*3

Rating

Power voltage

24 VDC ±10 %

Current consumption

450 mA or less

Environmental resistance

Ambient temperature

0 to +40 °C 32 to 104 °F

Relative humidity

35 to 65 % RH (No condensation)

Weight

Approx. 720 g

*1 Operating distance: 50 mm 1.96" (50 Hz), 600 mm 23.62" (8 Hz), 1,500 mm 59.05" (1 Hz). Downward air flow: 0.3 m/s. Air purge (3 NL/min) /1electrode
*2 Elective length indicates the static elimination rangeat 50 mm operating distance.
*3 The overall length includes mounting brackets.

Keyence Stock Image
Keyence SJ-M100 Keyence
Sale price $1,731.14
Only 4 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Keyence New Stock Image
Keyence SJ-M200 Keyence
Sale price $1,102.50
Only 9 units left

Specifications

Model

SJ-M200

Type

Controller

Voltage application method

Pulse AC method

Applied voltage

±5.5 kV

Rated output voltage

±6 kV

Ion balance control method

I.C.C. method

Static elimination time

0.5 sec. max.*1

Ion balance

±15 V*2

Supply pressure range

0.001 to 0.5 MPa*3

Control input

Static elimination stop input

Non-voltage input

Control output

Alarm output

NPN open-collector, 100 mA max. (40 V max.)

Ion level alarm output

Condition alarm output

Rating

Power voltage

24 VDC ±10%

Current consumption

450 mA max.

Environmental resistance

Ambient temperature

0 to +40°C 32 to +104°F

Relative humidity

35 to 65%RH (no condensation)*3

Weight

Approx. 300 g

*1 Operating distance: 50 mm 1.97", Air volume: 60 NL/min,
(Ambient temperature: 20 to 30°C 68 to 86°F, Ambient humidity: 40 to 60%RH)
*2 Operating distance: 50 mm 1.97", Air volume: 20 NL/min,
(Ambient temperature: 20 to 30°C 68 to 86°F, Ambient humidity: 40 to 60%RH)
*3 For derating of humidity and pressure during use at an ambient temperature higher than 35°C 95°F, contact KEYENCE. For air supply, use clean dry air with -20°C -4°F or lower dew point. The minimum air volume varies depending on the nozzle type. Contact KEYENCE for more information.

Keyence New Stock Image
Keyence SJ-M201 Keyence
Sale price $1,123.75
Only 9 units left

Specifications

Model

SJ-M201

Type

Controller Unit

Voltage application method

Pulse AC method

Applied voltage

±5.5 kV

Rated output voltage

±6 kV

Ion balance control method

I.C.C. method

Static elimination time

0.5 sec max. *1

Ion balance

±15 V or less *2

Supply pressure range

0.001 to 0.5 MPa *3

Control input

Static elimination stop input

Non-voltage input

Control output

Alarm output

NPN open c ollector 100 mA (40 V or less)

Ion level alarm output

Condition alarm output

Rating

Power voltage

24 VDC ±10 %

Current consumption

450 mA or less

Environmental resistance

Ambient temperature

0 to +40 °C 32 to 104 °F

Relative humidity

35 to 65 % RH

Weight

Approx. 300 g

*1 At installation distance 50 mm 1.97", air flow 60 Nl/min (ambient temperature 20 to 30°C 68 to 86°F, relative humidity 40 to 60%)
*2 Values obtained at an installation distance of 50 mm 1.97"
and air flow rate of 20 Nl/min [ambient operating temperature
+20 to +30°C +68 to +86°F, ambient operating humidity 40
to 60% RH] (without nozzle)
*3 Inquire for derating of humidity/pressure in environments exceeding
+35°C 95°F. Use clean or dry air at a temperature of -20°C -4°F or
less. Min. air pressure varies by nozzle used.

Keyence Stock Image
Keyence SJ-M300 Keyence
Sale price $445.92
Only 6 units left

Specifications

Model

SJ-M300

Type

Controller

Voltage application method

Pulse AC method

Applied voltage

±5.5 kV

Rated output voltage

±6 kV

Ion balance control method

I.C.C. method

Ion balance

±30 V*1

Supply pressure range

0.2 MPa max.

Control input

Static elimination stop input

Non-voltage input

Control output

Alarm output

NPN open-collector, 100 mA max. (40 V max.)

Ion level alarm output

Condition alarm output

Effective length

164 mm 6.46" (SJ-M030G,SJ-M030C)
324 mm 12.76" (SJ-M070G,SJ-M070C)
*2

Total length

220 mm 8.66" (SJ-M030G,SJ-M030C)
380 mm 14.96" (SJ-M070G,SJ-M070C)
*3

Rating

Power voltage

24 VDC ±10%

Current consumption

450 mA max.

Environmental resistance

Ambient temperature

0 to +40°C 32 to +104°F

Relative humidity

35 to 65%RH (no condensation)

Weight

Approx. 300 g

*1 Measured under the following conditions:
[SJ-M030G/M070G]
Air purge: 3 NL/min per electrode
Down flow: 0.3 m/s 0.98 ft/s
Operating distance: 50 mm 1.97"(50 Hz), 600 mm 23.62" (8 Hz), 1500 mm 59.06"(1 Hz)
[SJ-M030C/M070C]
Air purge: None
Down flow: 0.3 m/s 0.98 ft/s
Operating distance: 50 mm 1.97"(50 Hz), 600 mm 23.62" (8 Hz), 1500 mm 59.06"(1 Hz)
*2 Effective length indicates static elimination range at 50 mm 1.97" operating distance.
*3 Overall length includes mounting brackets.

Keyence Stock Image
Keyence SJ-M301 Keyence
Sale price $740.63
Only 3 units left

Specifications

Model

SJ-M301

Type

Controller

Voltage application method

Pulse AC method

Applied voltage

±5.5 kV

Rated output voltage

±6 kV

Ion balance control method

I.C.C. method

Ion balance

Control input

Static elimination stop input

Non-voltage input

Control output

Alarm output

NPN open c ollector 100 mA (40 V or less)

Ion level alarm output

Condition alarm output

Air purge supplied pressure

0.2MPa or less

Effective length

Total length

Rating

Power voltage

24 VDC ±10 %

Current consumption

450 mA or less

Environmental resistance

Ambient temperature

0 to +40 °C 32 to 104 °F

Relative humidity

35 to 65 % RH (No condensation)

Weight

Approx. 300 g

Keyence Stock Image
Keyence SJ-M400 Keyence
Sale price $1,626.25
Only 8 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

keyence Stock Image
Keyence SJ-ML Keyence
Sale price$0.00
Sold Out

Specifications

Model

SJ-ML

Applicable product

SJ-M Series

keyence Stock Image
Keyence SJ-ML1 Keyence
Sale price$0.00
Sold Out

Specifications

Model

SJ-ML1

Applicable product

SJ-M Series

keyence Stock Image
Keyence SJ-ML2 Keyence
Sale price$0.00
Sold Out

Specifications

Model

SJ-ML2

Applicable product

SJ-M Series

keyence Stock Image
Keyence SJ-MS1 Keyence
Sale price$0.00
Sold Out

Specifications

Model

SJ-MS1

Applicable product

SJ-M Series

keyence Stock Image
Keyence SJ-MS2 Keyence
Sale price$0.00
Sold Out

Specifications

Model

SJ-MS2

Applicable product

SJ-M Series

keyence Stock Image
Keyence SJ-Q01 Keyence
Sale price$0.00
Sold Out

Specifications

Model

SJ-Q01

Power source

4 AA size batteries

Operating temperature range

0 to +40°C

Operating humidity range

30-85% RH (no condensation)

Operating time

12 hours (continuous operation)/1 year (in standby mode)

Operation range

Within 4m in front
Within 2.5m and 45 degrees horizontally in relation to the front of the bar.
Within 2.5m and 30 degrees vertically in relation to the front of the bar.

Remote controller response time

During setting/batch acquisition: 1s or less
* Time for remote controller operation, unit processing, communication, and remote controller indication.

keyence Stock Image
Keyence SJ-Q036 Keyence
Sale price$0.00
Sold Out

Specifications

Model

SJ-Q036

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method / Applied voltage

Pulse AC method/±8000 Vmax

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±3 V *1

Clean rating

ISO14644-1 Class 3 *2

Installation distance

10 mm 0.39" or more

Control input

Static elimination stop input

NPN open collector or non-voltage contact signal

Control output

Ion level warning, condition warning, alarm output

NPN open collector
Maximum 100 mA (40 VDC or less)

Condition alarm output

Alarm output

Communication functions

Remote control

Average power consumption

Normal operation: 8.4 W,
LPC mode: 4.1 W
*3

Major functions

Condition alarm, ion level alarm, alarm output

Air connection port

Rc1/8

Air supply pressure

0.1 to 0.5 MPa 14.50 to 72.52 PSI (recommended air pressure: 0.2 MPa 29.01 PSI)*4

Effective length

440 mm 17.32" *5

Total length

350 mm 13.78"

No. ofelectrodes

5

Rating

Power voltage

24 to 36 VDC±10%

Current consumption

Normal operation: 700 mA or less,
LPC mode: 170 mA (typical)
*3

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

85% RH or less (no condensation)

Material

Electrode probe

Tungsten

Main body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

690 g 24.35 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81", Air supply pressure: 0.2 MPa 29.01 PSI, Frequency: Highest device driving frequency, Operating ambient temperature: 0 to +40°C 32 to 104°F, Operating ambient humidity: 35 to 65% RH, Measurement position: Bar Center
*2 Contact us for detailed conditions.
*3 24 VDC
*4 If you wish to use the air purge function with intermittent air supply, contact us.
*5 Effective length is for static elimination range when installation distance is 100 mm 3.94".

keyence Stock Image
Keyence SJ-Q060 Keyence
Sale price$0.00
Sold Out

Specifications

Model

SJ-Q060

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method / Applied voltage

Pulse AC method/±8000 Vmax

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±3 V *1

Clean rating

ISO14644-1 Class 3 *2

Installation distance

10 mm 0.39" or more

Control input

Static elimination stop input

NPN open collector or non-voltage contact signal

Control output

Ion level warning, condition warning, alarm output

NPN open collector
Maximum 100 mA (40 VDC or less)

Condition alarm output

Alarm output

Communication functions

Remote control

Average power consumption

Normal operation: 8.4 W,
LPC mode: 4.1 W
*3

Major functions

Condition alarm, ion level alarm, alarm output

Air connection port

Rc1/8

Air supply pressure

0.1 to 0.5 MPa 14.50 to 72.52 PSI (recommended air pressure: 0.2 MPa 29.01 PSI)*4

Effective length

680 mm 26.77" *5

Total length

560 mm 22.05"

No. ofelectrodes

9

Rating

Power voltage

24 to 36 VDC±10%

Current consumption

Normal operation: 700 mA or less,
LPC mode: 170 mA (typical)
*3

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

85% RH or less (no condensation)

Material

Electrode probe

Tungsten

Main body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

890 g 31.41 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81", Air supply pressure: 0.2 MPa 29.01 PSI, Frequency: Highest device driving frequency, Operating ambient temperature: 0 to +40°C 32 to 104°F, Operating ambient humidity: 35 to 65% RH, Measurement position: Bar Center
*2 Contact us for detailed conditions.
*3 24 VDC
*4 If you wish to use the air purge function with intermittent air supply, contact us.
*5 Effective length is for static elimination range when installation distance is 100 mm 3.94".

keyence Stock Image
Keyence SJ-Q084 Keyence
Sale price$0.00
Sold Out

Specifications

Model

SJ-Q084

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method / Applied voltage

Pulse AC method/±8000 Vmax

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±3 V *1

Clean rating

ISO14644-1 Class 3 *2

Installation distance

10 mm 0.39" or more

Control input

Static elimination stop input

NPN open collector or non-voltage contact signal

Control output

Ion level warning, condition warning, alarm output

NPN open collector
Maximum 100 mA (40 VDC or less)

Condition alarm output

Alarm output

Communication functions

Remote control

Average power consumption

Normal operation: 8.4 W,
LPC mode: 4.1 W
*3

Major functions

Condition alarm, ion level alarm, alarm output

Air connection port

Rc1/8

Air supply pressure

0.1 to 0.5 MPa 14.50 to 72.52 PSI (recommended air pressure: 0.2 MPa 29.01 PSI)*4

Effective length

920 mm 36.22" *5

Total length

800 mm 31.50"

No. ofelectrodes

13

Rating

Power voltage

24 to 36 VDC±10%

Current consumption

Normal operation: 700 mA or less,
LPC mode: 170 mA (typical)
*3

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

85% RH or less (no condensation)

Material

Electrode probe

Tungsten

Main body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

1120 g 39.53 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81", Air supply pressure: 0.2 MPa 29.01 PSI, Frequency: Highest device driving frequency, Operating ambient temperature: 0 to +40°C 32 to 104°F, Operating ambient humidity: 35 to 65% RH, Measurement position: Bar Center
*2 Contact us for detailed conditions.
*3 24 VDC
*4 If you wish to use the air purge function with intermittent air supply, contact us.
*5 Effective length is for static elimination range when installation distance is 100 mm 3.94".

keyence Stock Image
Keyence SJ-Q108 Keyence
Sale price$0.00
Sold Out

Specifications

Model

SJ-Q108

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method / Applied voltage

Pulse AC method/±8000 Vmax

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±3 V *1

Clean rating

ISO14644-1 Class 3 *2

Installation distance

10 mm 0.39" or more

Control input

Static elimination stop input

NPN open collector or non-voltage contact signal

Control output

Ion level warning, condition warning, alarm output

NPN open collector
Maximum 100 mA (40 VDC or less)

Condition alarm output

Alarm output

Communication functions

Remote control

Average power consumption

Normal operation: 8.4 W,
LPC mode: 4.1 W
*3

Major functions

Condition alarm, ion level alarm, alarm output

Air connection port

Rc1/8

Air supply pressure

0.1 to 0.5 MPa 14.50 to 72.52 PSI (recommended air pressure: 0.2 MPa 29.01 PSI)*4

Effective length

1160 mm 45.67" *5

Total length

1040 mm 40.94"

No. ofelectrodes

17

Rating

Power voltage

24 to 36 VDC±10%

Current consumption

Normal operation: 700 mA or less,
LPC mode: 170 mA (typical)
*3

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

85% RH or less (no condensation)

Material

Electrode probe

Tungsten

Main body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

1340 g 47.30 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81", Air supply pressure: 0.2 MPa 29.01 PSI, Frequency: Highest device driving frequency, Operating ambient temperature: 0 to +40°C 32 to 104°F, Operating ambient humidity: 35 to 65% RH, Measurement position: Bar Center
*2 Contact us for detailed conditions.
*3 24 VDC
*4 If you wish to use the air purge function with intermittent air supply, contact us.
*5 Effective length is for static elimination range when installation distance is 100 mm 3.94".

keyence Stock Image
Keyence SJ-Q132 Keyence
Sale price$0.00
Sold Out

Specifications

Model

SJ-Q132

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method / Applied voltage

Pulse AC method/±8000 Vmax

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±3 V *1

Clean rating

ISO14644-1 Class 3 *2

Installation distance

10 mm 0.39" or more

Control input

Static elimination stop input

NPN open collector or non-voltage contact signal

Control output

Ion level warning, condition warning, alarm output

NPN open collector
Maximum 100 mA (40 VDC or less)

Condition alarm output

Alarm output

Communication functions

Remote control

Average power consumption

Normal operation: 8.4 W,
LPC mode: 4.1 W
*3

Major functions

Condition alarm, ion level alarm, alarm output

Air connection port

Rc1/8

Air supply pressure

0.1 to 0.5 MPa 14.50 to 72.52 PSI (recommended air pressure: 0.2 MPa 29.01 PSI)*4

Effective length

1400 mm 55.12" *5

Total length

1280 mm 50.39"

No. ofelectrodes

21

Rating

Power voltage

24 to 36 VDC±10%

Current consumption

Normal operation: 700 mA or less,
LPC mode: 170 mA (typical)
*3

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

85% RH or less (no condensation)

Material

Electrode probe

Tungsten

Main body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

1580 g 55.77 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81", Air supply pressure: 0.2 MPa 29.01 PSI, Frequency: Highest device driving frequency, Operating ambient temperature: 0 to +40°C 32 to 104°F, Operating ambient humidity: 35 to 65% RH, Measurement position: Bar Center
*2 Contact us for detailed conditions.
*3 24 VDC
*4 If you wish to use the air purge function with intermittent air supply, contact us.
*5 Effective length is for static elimination range when installation distance is 100 mm 3.94".

keyence Stock Image
Keyence SJ-Q156 Keyence
Sale price$0.00
Sold Out

Specifications

Model

SJ-Q156

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method / Applied voltage

Pulse AC method/±8000 Vmax

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±3 V *1

Clean rating

ISO14644-1 Class 3 *2

Installation distance

10 mm 0.39" or more

Control input

Static elimination stop input

NPN open collector or non-voltage contact signal

Control output

Ion level warning, condition warning, alarm output

NPN open collector
Maximum 100 mA (40 VDC or less)

Condition alarm output

Alarm output

Communication functions

Remote control

Average power consumption

Normal operation: 8.4 W,
LPC mode: 4.1 W
*3

Major functions

Condition alarm, ion level alarm, alarm output

Air connection port

Rc1/8

Air supply pressure

0.1 to 0.5 MPa 14.50 to 72.52 PSI (recommended air pressure: 0.2 MPa 29.01 PSI)*4

Effective length

1640 mm 64.57" *5

Total length

1520 mm 59.84"

No. ofelectrodes

25

Rating

Power voltage

24 to 36 VDC±10%

Current consumption

Normal operation: 700 mA or less,
LPC mode: 170 mA (typical)
*3

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

85% RH or less (no condensation)

Material

Electrode probe

Tungsten

Main body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

1800 g 63.54 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81", Air supply pressure: 0.2 MPa 29.01 PSI, Frequency: Highest device driving frequency, Operating ambient temperature: 0 to +40°C 32 to 104°F, Operating ambient humidity: 35 to 65% RH, Measurement position: Bar Center
*2 Contact us for detailed conditions.
*3 24 VDC
*4 If you wish to use the air purge function with intermittent air supply, contact us.
*5 Effective length is for static elimination range when installation distance is 100 mm 3.94".

keyence Stock Image
Keyence SJ-Q180 Keyence
Sale price$0.00
Sold Out

Specifications

Model

SJ-Q180

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method / Applied voltage

Pulse AC method/±8000 Vmax

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±3 V *1

Clean rating

ISO14644-1 Class 3 *2

Installation distance

10 mm 0.39" or more

Control input

Static elimination stop input

NPN open collector or non-voltage contact signal

Control output

Ion level warning, condition warning, alarm output

NPN open collector
Maximum 100 mA (40 VDC or less)

Condition alarm output

Alarm output

Communication functions

Remote control

Average power consumption

Normal operation: 8.4 W,
LPC mode: 4.1 W
*3

Major functions

Condition alarm, ion level alarm, alarm output

Air connection port

Rc1/8

Air supply pressure

0.1 to 0.5 MPa 14.50 to 72.52 PSI (recommended air pressure: 0.2 MPa 29.01 PSI)*4

Effective length

1880 mm 74.02" *5

Total length

1760 mm 69.29"

No. ofelectrodes

29

Rating

Power voltage

24 to 36 VDC±10%

Current consumption

Normal operation: 700 mA or less,
LPC mode: 170 mA (typical)
*3

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

85% RH or less (no condensation)

Material

Electrode probe

Tungsten

Main body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

2010 g 70.95 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81", Air supply pressure: 0.2 MPa 29.01 PSI, Frequency: Highest device driving frequency, Operating ambient temperature: 0 to +40°C 32 to 104°F, Operating ambient humidity: 35 to 65% RH, Measurement position: Bar Center
*2 Contact us for detailed conditions.
*3 24 VDC
*4 If you wish to use the air purge function with intermittent air supply, contact us.
*5 Effective length is for static elimination range when installation distance is 100 mm 3.94".

keyence Stock Image
Keyence SJ-Q204 Keyence
Sale price$0.00
Sold Out

Specifications

Model

SJ-Q204

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method / Applied voltage

Pulse AC method/±8000 Vmax

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±3 V *1

Clean rating

ISO14644-1 Class 3 *2

Installation distance

10 mm 0.39" or more

Control input

Static elimination stop input

NPN open collector or non-voltage contact signal

Control output

Ion level warning, condition warning, alarm output

NPN open collector
Maximum 100 mA (40 VDC or less)

Condition alarm output

Alarm output

Communication functions

Remote control

Average power consumption

Normal operation: 8.4 W,
LPC mode: 4.1 W
*3

Major functions

Condition alarm, ion level alarm, alarm output

Air connection port

Rc1/8

Air supply pressure

0.1 to 0.5 MPa 14.50 to 72.52 PSI (recommended air pressure: 0.2 MPa 29.01 PSI)*4

Effective length

2120 mm 83.46" *5

Total length

2000 mm 78.74"

No. ofelectrodes

33

Rating

Power voltage

24 to 36 VDC±10%

Current consumption

Normal operation: 700 mA or less,
LPC mode: 170 mA (typical)
*3

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

85% RH or less (no condensation)

Material

Electrode probe

Tungsten

Main body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

2230 g 78.71 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81", Air supply pressure: 0.2 MPa 29.01 PSI, Frequency: Highest device driving frequency, Operating ambient temperature: 0 to +40°C 32 to 104°F, Operating ambient humidity: 35 to 65% RH, Measurement position: Bar Center
*2 Contact us for detailed conditions.
*3 24 VDC
*4 If you wish to use the air purge function with intermittent air supply, contact us.
*5 Effective length is for static elimination range when installation distance is 100 mm 3.94".

Recently viewed