Specifications
Model |
SJ-M070C |
|||
Type |
Head |
|||
Voltage application method |
Pulse AC method |
|||
Applied voltage |
±5.5 kV |
|||
Rated output voltage |
±6 kV |
|||
Ion balance control method |
I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Supply pressure range |
0.2 MPa max. |
|||
Control input |
Static elimination stop input |
Non-voltage input |
||
Control output |
Alarm output |
NPN open-collector, 100 mA max. (40 V max.) |
||
Ion level alarm output | ||||
Condition alarm output | ||||
Effective length |
324 mm 12.76"*2 |
|||
Total length |
380 mm 14.96"*3 |
|||
Rating |
Power voltage |
24 VDC ±10% |
||
Current consumption |
450 mA max. |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to +104°F |
||
Relative humidity |
35 to 65%RH (no condensation) |
|||
Weight |
Approx. 720 g |
|||
*1 Measured under the following conditions: | ||||

Specifications
Model |
SJ-M070G |
|||
Type |
Head |
|||
Voltage application method |
Pulse AC method |
|||
Applied voltage |
±5.5 kV |
|||
Rated output voltage |
±6 kV |
|||
Ion balance control method |
I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Supply pressure range |
0.2 MPa max. |
|||
Control input |
Static elimination stop input |
Non-voltage input |
||
Control output |
Alarm output |
NPN open-collector, 100 mA max. (40 V max.) |
||
Ion level alarm output | ||||
Condition alarm output | ||||
Effective length |
324 mm 12.76"*2 |
|||
Total length |
380 mm 14.96"*3 |
|||
Rating |
Power voltage |
24 VDC ±10% |
||
Current consumption |
450 mA max. |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to +104°F |
||
Relative humidity |
35 to 65%RH (no condensation) |
|||
Weight |
Approx. 720 g |
|||
*1 Measured under the following conditions: | ||||

Specifications
Model |
SJ-M071C |
|||
Type |
Head |
|||
Voltage application method |
Pulse AC method |
|||
Applied voltage |
±5.5 kV |
|||
Rated output voltage |
±6 kV |
|||
Ion balance control method |
I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Control input |
Static elimination stop input |
Non-voltage input |
||
Control output |
Alarm output |
NPN open collector 100 mA (40 V or less) |
||
Ion level alarm output | ||||
Condition alarm output | ||||
Air purge supplied pressure |
0.2 MPa or less |
|||
Effective length |
324 mm 12.756"*2 |
|||
Total length |
380 mm 14.961"*3 |
|||
Rating |
Power voltage |
24 VDC ±10 % |
||
Current consumption |
450 mA or less |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||
Relative humidity |
35 to 65 % RH (No condensation) |
|||
Weight |
Approx. 720 g |
|||
*1 Operating distance: 50 mm 1.96" (50 Hz), 600 mm 23.62" (8 Hz), 1,500 mm 59.05" (1 Hz). Downward air flow: 0.3 m/s. Air purge: None | ||||

Specifications
Model |
SJ-M071G |
|||
Type |
Head |
|||
Voltage application method |
Pulse AC method |
|||
Applied voltage |
±5.5 kV |
|||
Rated output voltage |
±6 kV |
|||
Ion balance control method |
I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Control input |
Static elimination stop input |
Non-voltage input |
||
Control output |
Alarm output |
NPN open collector 100 mA (40 V or less) |
||
Ion level alarm output | ||||
Condition alarm output | ||||
Air purge supplied pressure |
0.2 MPa or less |
|||
Effective length |
324 mm 12.756"*2 |
|||
Total length |
380 mm 14.961"*3 |
|||
Rating |
Power voltage |
24 VDC ±10 % |
||
Current consumption |
450 mA or less |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||
Relative humidity |
35 to 65 % RH (No condensation) |
|||
Weight |
Approx. 720 g |
|||
*1 Operating distance: 50 mm 1.96" (50 Hz), 600 mm 23.62" (8 Hz), 1,500 mm 59.05" (1 Hz). Downward air flow: 0.3 m/s. Air purge (3 NL/min) /1electrode | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
SJ-M200 |
|||
Type |
Controller |
|||
Voltage application method |
Pulse AC method |
|||
Applied voltage |
±5.5 kV |
|||
Rated output voltage |
±6 kV |
|||
Ion balance control method |
I.C.C. method |
|||
Static elimination time |
0.5 sec. max.*1 |
|||
Ion balance |
±15 V*2 |
|||
Supply pressure range |
0.001 to 0.5 MPa*3 |
|||
Control input |
Static elimination stop input |
Non-voltage input |
||
Control output |
Alarm output |
NPN open-collector, 100 mA max. (40 V max.) |
||
Ion level alarm output | ||||
Condition alarm output | ||||
Rating |
Power voltage |
24 VDC ±10% |
||
Current consumption |
450 mA max. |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to +104°F |
||
Relative humidity |
35 to 65%RH (no condensation)*3 |
|||
Weight |
Approx. 300 g |
|||
*1 Operating distance: 50 mm 1.97", Air volume: 60 NL/min, | ||||

Specifications
Model |
SJ-M201 |
|||
Type |
Controller Unit |
|||
Voltage application method |
Pulse AC method |
|||
Applied voltage |
±5.5 kV |
|||
Rated output voltage |
±6 kV |
|||
Ion balance control method |
I.C.C. method |
|||
Static elimination time |
0.5 sec max. *1 |
|||
Ion balance |
±15 V or less *2 |
|||
Supply pressure range |
0.001 to 0.5 MPa *3 |
|||
Control input |
Static elimination stop input |
Non-voltage input |
||
Control output |
Alarm output |
NPN open c ollector 100 mA (40 V or less) |
||
Ion level alarm output | ||||
Condition alarm output | ||||
Rating |
Power voltage |
24 VDC ±10 % |
||
Current consumption |
450 mA or less |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||
Relative humidity |
35 to 65 % RH |
|||
Weight |
Approx. 300 g |
|||
*1 At installation distance 50 mm 1.97", air flow 60 Nl/min (ambient temperature 20 to 30°C 68 to 86°F, relative humidity 40 to 60%) | ||||

Specifications
Model |
SJ-M300 |
|||
Type |
Controller |
|||
Voltage application method |
Pulse AC method |
|||
Applied voltage |
±5.5 kV |
|||
Rated output voltage |
±6 kV |
|||
Ion balance control method |
I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Supply pressure range |
0.2 MPa max. |
|||
Control input |
Static elimination stop input |
Non-voltage input |
||
Control output |
Alarm output |
NPN open-collector, 100 mA max. (40 V max.) |
||
Ion level alarm output | ||||
Condition alarm output | ||||
Effective length |
164 mm 6.46" (SJ-M030G,SJ-M030C) |
|||
Total length |
220 mm 8.66" (SJ-M030G,SJ-M030C) |
|||
Rating |
Power voltage |
24 VDC ±10% |
||
Current consumption |
450 mA max. |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to +104°F |
||
Relative humidity |
35 to 65%RH (no condensation) |
|||
Weight |
Approx. 300 g |
|||
*1 Measured under the following conditions: | ||||

Specifications
Model |
SJ-M301 |
|||
Type |
Controller |
|||
Voltage application method |
Pulse AC method |
|||
Applied voltage |
±5.5 kV |
|||
Rated output voltage |
±6 kV |
|||
Ion balance control method |
I.C.C. method |
|||
Ion balance |
― |
|||
Control input |
Static elimination stop input |
Non-voltage input |
||
Control output |
Alarm output |
NPN open c ollector 100 mA (40 V or less) |
||
Ion level alarm output | ||||
Condition alarm output | ||||
Air purge supplied pressure |
0.2MPa or less |
|||
Effective length |
― |
|||
Total length | ||||
Rating |
Power voltage |
24 VDC ±10 % |
||
Current consumption |
450 mA or less |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||
Relative humidity |
35 to 65 % RH (No condensation) |
|||
Weight |
Approx. 300 g |
|||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
SJ-Q01 |
|||
Power source |
4 AA size batteries |
|||
Operating temperature range |
0 to +40°C |
|||
Operating humidity range |
30-85% RH (no condensation) |
|||
Operating time |
12 hours (continuous operation)/1 year (in standby mode) |
|||
Operation range |
Within 4m in front |
|||
Remote controller response time |
During setting/batch acquisition: 1s or less |
|||

Specifications
Model |
SJ-Q036 |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 Vmax |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±3 V *1 |
|||
Clean rating |
ISO14644-1 Class 3 *2 |
|||
Installation distance |
10 mm 0.39" or more |
|||
Control input |
Static elimination stop input |
NPN open collector or non-voltage contact signal |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector |
||
Condition alarm output | ||||
Alarm output | ||||
Communication functions |
Remote control |
|||
Average power consumption |
Normal operation: 8.4 W, |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc1/8 |
|||
Air supply pressure |
0.1 to 0.5 MPa 14.50 to 72.52 PSI (recommended air pressure: 0.2 MPa 29.01 PSI)*4 |
|||
Effective length |
440 mm 17.32" *5 |
|||
Total length |
350 mm 13.78" |
|||
No. ofelectrodes |
5 |
|||
Rating |
Power voltage |
24 to 36 VDC±10% |
||
Current consumption |
Normal operation: 700 mA or less, |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
85% RH or less (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
690 g 24.35 oz |
|||
*1 Measured under the following conditions. | ||||

Specifications
Model |
SJ-Q060 |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 Vmax |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±3 V *1 |
|||
Clean rating |
ISO14644-1 Class 3 *2 |
|||
Installation distance |
10 mm 0.39" or more |
|||
Control input |
Static elimination stop input |
NPN open collector or non-voltage contact signal |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector |
||
Condition alarm output | ||||
Alarm output | ||||
Communication functions |
Remote control |
|||
Average power consumption |
Normal operation: 8.4 W, |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc1/8 |
|||
Air supply pressure |
0.1 to 0.5 MPa 14.50 to 72.52 PSI (recommended air pressure: 0.2 MPa 29.01 PSI)*4 |
|||
Effective length |
680 mm 26.77" *5 |
|||
Total length |
560 mm 22.05" |
|||
No. ofelectrodes |
9 |
|||
Rating |
Power voltage |
24 to 36 VDC±10% |
||
Current consumption |
Normal operation: 700 mA or less, |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
85% RH or less (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
890 g 31.41 oz |
|||
*1 Measured under the following conditions. | ||||

Specifications
Model |
SJ-Q084 |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 Vmax |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±3 V *1 |
|||
Clean rating |
ISO14644-1 Class 3 *2 |
|||
Installation distance |
10 mm 0.39" or more |
|||
Control input |
Static elimination stop input |
NPN open collector or non-voltage contact signal |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector |
||
Condition alarm output | ||||
Alarm output | ||||
Communication functions |
Remote control |
|||
Average power consumption |
Normal operation: 8.4 W, |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc1/8 |
|||
Air supply pressure |
0.1 to 0.5 MPa 14.50 to 72.52 PSI (recommended air pressure: 0.2 MPa 29.01 PSI)*4 |
|||
Effective length |
920 mm 36.22" *5 |
|||
Total length |
800 mm 31.50" |
|||
No. ofelectrodes |
13 |
|||
Rating |
Power voltage |
24 to 36 VDC±10% |
||
Current consumption |
Normal operation: 700 mA or less, |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
85% RH or less (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
1120 g 39.53 oz |
|||
*1 Measured under the following conditions. | ||||

Specifications
Model |
SJ-Q108 |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 Vmax |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±3 V *1 |
|||
Clean rating |
ISO14644-1 Class 3 *2 |
|||
Installation distance |
10 mm 0.39" or more |
|||
Control input |
Static elimination stop input |
NPN open collector or non-voltage contact signal |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector |
||
Condition alarm output | ||||
Alarm output | ||||
Communication functions |
Remote control |
|||
Average power consumption |
Normal operation: 8.4 W, |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc1/8 |
|||
Air supply pressure |
0.1 to 0.5 MPa 14.50 to 72.52 PSI (recommended air pressure: 0.2 MPa 29.01 PSI)*4 |
|||
Effective length |
1160 mm 45.67" *5 |
|||
Total length |
1040 mm 40.94" |
|||
No. ofelectrodes |
17 |
|||
Rating |
Power voltage |
24 to 36 VDC±10% |
||
Current consumption |
Normal operation: 700 mA or less, |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
85% RH or less (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
1340 g 47.30 oz |
|||
*1 Measured under the following conditions. | ||||

Specifications
Model |
SJ-Q132 |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 Vmax |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±3 V *1 |
|||
Clean rating |
ISO14644-1 Class 3 *2 |
|||
Installation distance |
10 mm 0.39" or more |
|||
Control input |
Static elimination stop input |
NPN open collector or non-voltage contact signal |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector |
||
Condition alarm output | ||||
Alarm output | ||||
Communication functions |
Remote control |
|||
Average power consumption |
Normal operation: 8.4 W, |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc1/8 |
|||
Air supply pressure |
0.1 to 0.5 MPa 14.50 to 72.52 PSI (recommended air pressure: 0.2 MPa 29.01 PSI)*4 |
|||
Effective length |
1400 mm 55.12" *5 |
|||
Total length |
1280 mm 50.39" |
|||
No. ofelectrodes |
21 |
|||
Rating |
Power voltage |
24 to 36 VDC±10% |
||
Current consumption |
Normal operation: 700 mA or less, |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
85% RH or less (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
1580 g 55.77 oz |
|||
*1 Measured under the following conditions. | ||||

Specifications
Model |
SJ-Q156 |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 Vmax |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±3 V *1 |
|||
Clean rating |
ISO14644-1 Class 3 *2 |
|||
Installation distance |
10 mm 0.39" or more |
|||
Control input |
Static elimination stop input |
NPN open collector or non-voltage contact signal |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector |
||
Condition alarm output | ||||
Alarm output | ||||
Communication functions |
Remote control |
|||
Average power consumption |
Normal operation: 8.4 W, |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc1/8 |
|||
Air supply pressure |
0.1 to 0.5 MPa 14.50 to 72.52 PSI (recommended air pressure: 0.2 MPa 29.01 PSI)*4 |
|||
Effective length |
1640 mm 64.57" *5 |
|||
Total length |
1520 mm 59.84" |
|||
No. ofelectrodes |
25 |
|||
Rating |
Power voltage |
24 to 36 VDC±10% |
||
Current consumption |
Normal operation: 700 mA or less, |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
85% RH or less (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
1800 g 63.54 oz |
|||
*1 Measured under the following conditions. | ||||

Specifications
Model |
SJ-Q180 |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 Vmax |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±3 V *1 |
|||
Clean rating |
ISO14644-1 Class 3 *2 |
|||
Installation distance |
10 mm 0.39" or more |
|||
Control input |
Static elimination stop input |
NPN open collector or non-voltage contact signal |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector |
||
Condition alarm output | ||||
Alarm output | ||||
Communication functions |
Remote control |
|||
Average power consumption |
Normal operation: 8.4 W, |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc1/8 |
|||
Air supply pressure |
0.1 to 0.5 MPa 14.50 to 72.52 PSI (recommended air pressure: 0.2 MPa 29.01 PSI)*4 |
|||
Effective length |
1880 mm 74.02" *5 |
|||
Total length |
1760 mm 69.29" |
|||
No. ofelectrodes |
29 |
|||
Rating |
Power voltage |
24 to 36 VDC±10% |
||
Current consumption |
Normal operation: 700 mA or less, |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
85% RH or less (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
2010 g 70.95 oz |
|||
*1 Measured under the following conditions. | ||||

Specifications
Model |
SJ-Q204 |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 Vmax |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±3 V *1 |
|||
Clean rating |
ISO14644-1 Class 3 *2 |
|||
Installation distance |
10 mm 0.39" or more |
|||
Control input |
Static elimination stop input |
NPN open collector or non-voltage contact signal |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector |
||
Condition alarm output | ||||
Alarm output | ||||
Communication functions |
Remote control |
|||
Average power consumption |
Normal operation: 8.4 W, |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc1/8 |
|||
Air supply pressure |
0.1 to 0.5 MPa 14.50 to 72.52 PSI (recommended air pressure: 0.2 MPa 29.01 PSI)*4 |
|||
Effective length |
2120 mm 83.46" *5 |
|||
Total length |
2000 mm 78.74" |
|||
No. ofelectrodes |
33 |
|||
Rating |
Power voltage |
24 to 36 VDC±10% |
||
Current consumption |
Normal operation: 700 mA or less, |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
85% RH or less (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
2230 g 78.71 oz |
|||
*1 Measured under the following conditions. | ||||