keyence Stock Image
Keyence SJ-H300C Keyence
Sale price$0.00
Sold Out

Specifications

Model

SJ-H300C

Type

HC

Ion generation method

Corona discharge

Structure

Shock-proof, resistance-coupled

Voltage application method/applied voltage

Pulse AC method/±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Cleanliness

ISO 14644-1 Class 2 *2

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or non-voltage contact signal

Control output

NPN type photorelay, 100 mA max. (at 40 V max.)

Major functions

Condition alarm output, ion level alarm output, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *3

Effective length

3000 mm 118.11" *4

No. ofelectrodes

48

Static elimination bar length

2960 mm 116.54"

Rating

Power voltage

24 VDC-36 V±10%

Current consumption

500 mA (at 24 VDC)/350 mA (at 36 VDC)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32.0°F to 104.0°F

Relative humidity

35 to 85% RH (No condensation)

Material

Electrode probe

Silicon

Main unit

ABS resin/PC

Weight

Static elimination bar

3150 g 111.11 oz

*1 Value measured under the following conditions:
Operating distance: 300 mm 11.81"
Air supply pressure: 0.2 MPa
Frequency: 68 Hz
Ambient operating temperature: 0 to +40°C 32.0°F to 104.0°F
Ambient operating humidity: 35 to 65%RH
Measurement position: Center of bar
* Under a 0.3 m/s 1.0 ft/s downflow
*2 Contact KEYENCE for detailed conditions.
*3 Contact KEYENCE when using the air purge function with intermittent air supply.
*4 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-HM01 Keyence
Sale price$0.00
Sold Out

Specifications

Model

SJ-HM01

Overview

Used over areas where auxiliary air should not be used.

keyence Stock Image
Keyence SJ-HS01 Keyence
Sale price$0.00
Sold Out

Specifications

Model

SJ-HS01

Type

Straight air booster starter unit

keyence Stock Image
Keyence SJ-HS02 Keyence
Sale price$0.00
Sold Out

Specifications

Model

SJ-HS02

Type

Extension unit for straight air booster

keyence Stock Image
Keyence SJ-HW01 Keyence
Sale price$0.00
Sold Out

Specifications

Model

SJ-HW01

Type

Wide angle booster starter unit
Used to widen the static elimination range.

keyence Stock Image
Keyence SJ-HW02 Keyence
Sale price$0.00
Sold Out

Specifications

Model

SJ-HW02

Type

Extension unit for wide angle booster
Used to extend the auxiliary air diffusion unit.

keyence Stock Image
Keyence SJ-L005F Keyence
Sale price $793.50
Only 6 units left

Specifications

Model

SJ-L005F

Voltage application method

High frequency AC method

Applied voltage

3 kVAC

Ion balance

±10 V *1

Installation distance

50 mm 1.97 " or greater

Maximum air speed

7 m/s *1

Maximum air flow

0.16 m3/min

Ozone concentration

0.05 ppm or less *1

Control input

Static elimination stop input

Can switch between “non-voltage input” and “voltage input” *2*3
For non-voltage input: ON voltage 2 V or lower, OFF current 0.1 mA or lower, ON current 2 mA or lower (short circuit)
For voltage input: Maximum input rating 30 V , ON voltage 18 V or higher, OFF current 0.1 mA or lower, ON current 1 mA or lower (at 30 V)

Control output

Alarm (N.C.) /Ion level alarm (N.O.)

Open collector output: 30 V DC or less
Maximum 50 mA or lower, Residual voltage 1 V or lower
Switchable between NPN/PNP settings *2*3

Power supply

Power voltage

24 V DC ±10 % (including ripple) or 12 V DC
(dedicated AC adapter OP-88020/87722 *4)

Power consumption

310 mA or less (for 24 V DC)
600 mA or less (for 12 V DC)

Environmental resistance

Ambient temperature

0 to +50 °C 32 to +122 °F
(When using OP-87722, 0 to +40 °C 32 to +104 °F)

Relative humidity

35 to 65 % RH (assuming no condensation)

Overvoltage category

I

Pollution degree

2

Weight

Approx. 100 g (main unit weight)

*1 Measurement results taken with an installation distance of 100 mm 3.94 " , maximum air flow and no air filter. (Representative values)
*2 Cannot be used when the power supply is an AC adapter
*3 “Static elimination stop input” and “ion level alarm output” are allocated to the white line using the setting switch.
*4 Rated input of 100 to 240 V AC , 50/60 Hz

keyence Stock Image
Keyence SJ-L005G Keyence
Sale price $1,791.59
Only 4 units left

Specifications

Model

SJ-L005G

Voltage application method

High frequency AC method

Applied voltage

3.2 kVAC

Ion balance

±10 V*1

Static elimination time

0.4 sec.*1

Operating distance

50 mm 1.97" or more

Air supply pressure

0.05 to 0.7 Mpa

Air supply temperature

0 to +50°C 32 to 122°F

Connection tube

Outer diameter: ø8 0.31", inner diameter: ø6 0.24"

Ozone concentration

0.05 ppm or less*2

Ratings

Power voltage

12 VDC (dedicated AC adapter OP-88020/87722 *3)

Current consumption

0.3 A max.

Environmental resistance

Ambient temperature

0 to +50°C 32 to 122°F (0 to +40°C 32 to 104°F when OP-87722 is used)

Relative humidity

35 to 65% RH (no condensation)

Overvoltage category

I

Pollution degree

2

Drop resistance

Onto concrete from a height of 2.0 m 6.6'*4

Material

Main unit case: PC / Status indicator: TPU / Cable: PVC, copper alloy
Main unit connector: PBT, brass + Ni plating, brass + gold plating
Protection rubber: HNBR (tip side), NBR (connector side)

Weight

Approx. 320 g

*1 Measurement results taken with an installation distance of 150 mm 5.91" and air supply pressure of 0.2 MPa (typical values)
*2 Measurement results taken with an installation distance of 100 mm 3.94" and air supply pressure of 0.1 MPa (typical values)
*3 Rated input of 100 to 240 VAC, 50/60 Hz
*4 This is a typical value under KEYENCE measurement conditions and not a guaranteed value.

keyence Stock Image
Keyence SJ-L005M Keyence
Sale price $1,179.87
Only 5 units left

Specifications

Model

SJ-L005M

Type

Nozzle type

Voltage application method

High frequency AC method

Applied voltage

2.2 kVAC

Ion balance

±10 V*1

Static elimination time

0.4 sec.*1

Air supply pressure

0.05 to 0.5 MPa

Air supply temperature

0 to +50°C 32 to 122°F

Connection tube

Outer diameter: ø6 0.24", inner diameter: ø4 0.16"

Ozone concentration

0.05 ppm or less*2

Control input

Static elimination stop input

Switchable between non-voltage input and voltage input
Non-voltage input: ON voltage 2 V or lower, OFF current 0.1 mA or lower, ON current 2 mA or lower (short circuit)
Voltage input: Maximum input rating 30 V, ON voltage 7 V or higher, OFF current 0.1 mA or lower, ON current 1.5 mA or lower (at 30 V)*3

Reset input

LPC mode input

Control output

Alarm (N.C.)/Ion level alarm (N.O.)

Open-collector output 30 VDC or less
50 mA max., residual voltage 1.5 V or less
NPN/PNP settings switchable*3*4

Ratings

Power voltage

24 VDC ±10% (including ripple) or
12 VDC (dedicated AC adapter OP-88020/87722*5)

Current consumption

0.2 A or less (24 VDC)
0.3 A or less (12 VDC)

Environmental resistance

Ambient temperature

0 to +50°C 32 to 122°F (0 to +40°C 32 to 104°F when OP-87722 is used)

Relative humidity

35 to 65% RH (no condensation)

Overvoltage category

I

Pollution degree

2

Material

Main unit case: PBT / Charge indicator: TPU / Securing bracket: SUS303, PBT
Cable: PVC, TPE, copper alloy
Connector: PBT, brass + gold plating, phosphor bronze + gold plating, coper alloy + gold plating
Fitting: Brass + electroless Ni plating, POM, NBR

Weight

Approx. 60 g

*1 Measurement results taken with an installation distance of 150 mm 5.91", air supply pressure of 0.2 MPa, and a nozzle angle of 90° (typical values)
*2 Measurement results taken with an installation distance of 100 mm 3.94", air supply pressure of 0.1 MPa, and a nozzle angle of 90° (typical values)
*3 Cannot be used when the power supply is the AC adapter.
*4 To use the ion level alarm with the tube type, use it with air supply pressure of 0.3 MPa or less.
*5 Rated input of 100 to 240 VAC, 50/60 Hz

keyence Stock Image
Keyence SJ-L005MT Keyence
Sale price $1,665.18
Only 2 units left

Specifications

Model

SJ-L005MT

Type

Tube type

Voltage application method

High frequency AC method (68 kHz)

Applied voltage

2.5 kVAC

Ion balance

±10 V*1

Static elimination time

See Data Sheet.

Air supply pressure

0.05 to 0.5 MPa

Air supply temperature

0 to +50°C 32 to 122°F

Connection tube

Outer diameter: ø6 0.24", inner diameter: ø4 0.16"

Ozone concentration

0.05 ppm or less*2

Control input

Static elimination stop input

Switchable between non-voltage input and voltage input
Non-voltage input: ON voltage 2 V or lower, OFF current 0.1 mA or lower, ON current 2 mA or lower (short circuit)
Voltage input: Maximum input rating 30 V, ON voltage 7 V or higher, OFF current 0.1 mA or lower, ON current 1.5 mA or lower (at 30 V)*3

Reset input

LPC mode input

Control output

Alarm (N.C.)/Ion level alarm (N.O.)

Open-collector output 30 VDC or less
50 mA max., residual voltage 1.5 V or less
NPN/PNP settings switchable*3*4

Ratings

Power voltage

24 VDC ±10% (including ripple) or
12 VDC (dedicated AC adapter OP-88020/87722*5)

Current consumption

0.2 A or less (24 VDC)
0.3 A or less (12 VDC)

Environmental resistance

Ambient temperature

0 to +50°C 32 to 122°F (0 to +40°C 32 to 104°F when OP-87722 is used)

Relative humidity

35 to 65% RH (no condensation)

Overvoltage category

I

Pollution degree

2

Material

Main unit case: PBT / Charge indicator: TPU / Securing bracket: SUS303, PBT
Cable: PVC, TPE, copper alloy
Connector: PBT, brass + gold plating, phosphor bronze + gold plating, coper alloy + gold plating
Fitting: Brass + electroless Ni plating, POM, NBR

Weight

Approx. 65 g

*1 Measurement results taken with tube length of 500 mm 19.69", an installation distance of 50 mm 1.97", and air supply pressure of 0.2 MPa (typical values)
*2 Measurement results taken with tube length of 500 mm 19.69", an installation distance of 300 mm 11.81", and air supply pressure of 0.1 MPa (typical values)
*3 Cannot be used when the power supply is the AC adapter.
*4 To use the ion level alarm with the tube type, use it with air supply pressure of 0.3 MPa or less.
*5 Rated input of 100 to 240 VAC, 50/60 Hz

keyence Stock Image
Keyence SJ-LM1 Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence SJ-LM2 Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence New Stock Image
Keyence SJ-M010 Keyence
Sale price $1,696.05
Only 6 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence New Stock Image
Keyence SJ-M020 Keyence
Sale price $1,463.41
Only 7 units left

Specifications

Model

SJ-M020

Type

Head

Voltage application method

Pulse AC method

Applied voltage

±5.5 kV

Rated output voltage

±6 kV

Ion balance control method

I.C.C. method

Static elimination time

0.5 sec. max.*1

Ion balance

±15 V*2

Supply pressure range

0.001 to 0.5 MPa*3

Control input

Static elimination stop input

Non-voltage input

Control output

Alarm output

NPN open-collector, 100 mA max. (40 V max.)

Ion level alarm output

Condition alarm output

Rating

Power voltage

24 VDC ±10%

Current consumption

450 mA max.

Environmental resistance

Ambient temperature

0 to +80°C 32 to +176°F*4*5

Relative humidity

35 to 65%RH (no condensation)*3

Weight

Approx. 600 g

*1 Operating distance: 50 mm 1.97", Air volume: 60 NL/min,
(Ambient temperature: 20 to 30°C 68 to 86°F, Ambient humidity: 40 to 60%RH)
*2 Operating distance: 50 mm 1.97", Air volume: 20 NL/min,
(Ambient temperature: 20 to 30°C 68 to 86°F, Ambient humidity: 40 to 60%RH)
*3 For derating of humidity and pressure during use at an ambient temperature higher than 35°C 95°F, contact KEYENCE. For air supply, use clean dry air with -20°C -4°F or lower dew point. The minimum air volume varies depending on the nozzle type. Contact KEYENCE for more information.
*4 The supplied air temperature should be 40°C 104°F or less.
*5 For high-pressure cable only. For other parts, operating ambient temperature is 0 to +40°C 32 to +104°F.

Keyence Stock Image
Keyence SJ-M020G Keyence
Sale price $1,308.22
Only 9 units left

Specifications

Model

SJ-M020G

Type

Head

Voltage application method

Pulse AC method

Applied voltage

±5.5 kV

Rated output voltage

±6 kV

Ion balance control method

I.C.C. method

Static elimination time

0.5 sec. max.*1

Ion balance

±15 V*2

Supply pressure range

0.001 to 0.5 MPa*3

Control input

Static elimination stop input

Non-voltage input

Control output

Alarm output

NPN open-collector, 100 mA max. (40 V max.)

Ion level alarm output

Condition alarm output

Rating

Power voltage

24 VDC ±10%

Current consumption

450 mA max.

Environmental resistance

Ambient temperature

0 to +80°C 32 to +176°F*4*5

Relative humidity

35 to 65%RH (no condensation)*3

Weight

Approx. 600 g

*1 Operating distance: 50 mm 1.97", Air volume: 60 NL/min,
(Ambient temperature: 20 to 30°C 68 to 86°F, Ambient humidity: 40 to 60%RH)
*2 Operating distance: 50 mm 1.97", Air volume: 20 NL/min,
(Ambient temperature: 20 to 30°C 68 to 86°F, Ambient humidity: 40 to 60%RH)
*3 For derating of humidity and pressure during use at an ambient temperature higher than 35°C 95°F, contact KEYENCE. For air supply, use clean dry air with -20°C -4°F or lower dew point. The minimum air volume varies depending on the nozzle type. Contact KEYENCE for more information.
*4 The supplied air temperature should be 40°C 104°F or less.
*5 For high-pressure cable only. For other parts, operating ambient temperature is 0 to +40°C 32 to +104°F.

Keyence Stock Image
Keyence SJ-M021 Keyence
Sale price $3,562.62
Only 6 units left

Specifications

Model

SJ-M021

Type

Static Elimination Head

Voltage application method

Pulse AC method

Applied voltage

±5.5 kV

Rated output voltage

±6 kV

Ion balance control method

I.C.C. method

Static elimination time

0.5 sec max.*1

Ion balance

±15 V or less*2

Supply pressure range

0.001 to 0.5 MPa*3

Min. air pressure

With SJ-ML

0.02 MPa (20 Nl/min)

With SJ-MS/ML1

0.03 MPa (20 Nl/min)

With SJ-MS/ML2

0.02 MPa (20 Nl/min)

With SJ-MS/ML3

0.08 MPa (50 Nl/min)

With SJ-MS/ML4

Control input

Static elimination stop input

Non-voltage input

Control output

Alarm output

NPN open collector 100 mA (40 V or less)

Ion level alarm output

Condition alarm output

Rating

Power voltage

24 VDC ±10 %

Current consumption

450 mA or less

Environmental resistance

Ambient temperature

0 to +80 °C 32 to 176 °F*4*5

Relative humidity

35 to 65 % RH

Weight

Approx. 600 g

*1 At installation distance 50 mm 1.97", air flow 60 Nl/min (ambient temperature 20 to 30 °C 68 to 86 °F, relative humidity 40 to 60 %)
*2 Values obtained at an installation distance of 50 mm 1.97" and air flow rate of 20 Nl/min [ambient operating temperature +20 to +30 °C +68 to +86 °F, ambient operating humidity 40 to 60 % RH] (without nozzle)
*3 Inquire for derating of humidity/pressure in environments exceeding +35 °C 95 °F. Use clean or dry air at a temperature of -20 °C -4 °F or less. Min. air pressure varies by nozzle used.
*4 Use a supplied fluid with a temperature of 40 °C 104 °F or less.
*5 Only for the pressure cable. Other parts should be used with an ambient temperature of 0 to 40 °C 104 °F.

Keyence New Stock Image
Keyence SJ-M021G Keyence
Sale price $2,617.25
Only 5 units left

Specifications

Model

SJ-M021G

Type

Static Elimination Head

Voltage application method

Pulse AC method

Applied voltage

±5.5 kV

Rated output voltage

±6 kV

Ion balance control method

I.C.C. method

Static elimination time

0.5 sec max.*1

Ion balance

±15 V or less*2

Supply pressure range

0.001 to 0.5 MPa*3

Min. air pressure

With SJ-ML

0.02 MPa (20 Nl/min)

With SJ-MS/ML1

0.03 MPa (20 Nl/min)

With SJ-MS/ML2

0.02 MPa (20 Nl/min)

With SJ-MS/ML3

0.08 MPa (50 Nl/min)

With SJ-MS/ML4

Control input

Static elimination stop input

Non-voltage input

Control output

Alarm output

NPN open collector 100 mA (40 V or less)

Ion level alarm output

Condition alarm output

Rating

Power voltage

24 VDC ±10 %

Current consumption

450 mA or less

Environmental resistance

Ambient temperature

0 to +80 °C 32 to 176 °F*4*5

Relative humidity

35 to 65 % RH

Weight

Approx. 600 g

*1 At installation distance 50 mm 1.97", air flow 60 Nl/min (ambient temperature 20 to 30 °C 68 to 86 °F, relative humidity 40 to 60 %)
*2 Values obtained at an installation distance of 50 mm 1.97" and air flow rate of 20 Nl/min [ambient operating temperature +20 to +30 °C +68 to +86 °F, ambient operating humidity 40 to 60 % RH] (without nozzle)
*3 Inquire for derating of humidity/pressure in environments exceeding +35 °C 95 °F. Use clean or dry air at a temperature of -20 °C -4 °F or less. Min. air pressure varies by nozzle used.
*4 Use a supplied fluid with a temperature of 40 °C 104 °F or less.
*5 Only for the pressure cable. Other parts should be used with an ambient temperature of 0 to 40 °C 104 °F.

Keyence Stock Image
Keyence SJ-M030 Keyence
Sale price $880.85
Only 9 units left

Specifications

Model

SJ-M030

Type

Head

Voltage application method

Pulse AC method

Applied voltage

±5.5 kV

Rated output voltage

±6 kV

Ion balance control method

I.C.C. method

Ion balance

±30 V*1

Supply pressure range

0.2 MPa or less

Control input

Static elimination stop input

Non-voltage input

Control output

Alarm output

NPN open collector 100 mA (40 V or less)

Ion level alarm output

Condition alarm output

Effective length

164 mm 6.457"

Total length

220 mm 8.661"

Rating

Power voltage

24 VDC ±10 %

Current consumption

450 mA or less

Environmental resistance

Ambient temperature

0 to +40 °C 32 to 104 °F

Relative humidity

35 to 65 % RH (No condensation)

Weight

Approx. 600 g

*1 Please make an inquiry as to the measurement condition.

keyence Stock Image
Keyence SJ-M030C Keyence
Sale price $3,391.13
Only 2 units left

Specifications

Model

SJ-M030C

Type

Head

Voltage application method

Pulse AC method

Applied voltage

±5.5 kV

Rated output voltage

±6 kV

Ion balance control method

I.C.C. method

Ion balance

±30 V*1

Supply pressure range

0.2 MPa max.

Control input

Static elimination stop input

Non-voltage input

Control output

Alarm output

NPN open-collector, 100 mA max. (40 V max.)

Ion level alarm output

Condition alarm output

Effective length

164 mm 6.46"*2

Total length

220 mm 8.66"*3

Rating

Power voltage

24 VDC ±10%

Current consumption

450 mA max.

Environmental resistance

Ambient temperature

0 to +40°C 32 to +104°F

Relative humidity

35 to 65%RH (no condensation)

Weight

Approx. 600 g

*1 Measured under the following conditions:
[SJ-M030G/M070G]
Air purge: 3 NL/min per electrode
Down flow: 0.3 m/s 0.98 ft/s
Operating distance: 50 mm 1.97"(50 Hz), 600 mm 23.62" (8 Hz), 1500 mm 59.06"(1 Hz)
[SJ-M030C/M070C]
Air purge: None
Down flow: 0.3 m/s 0.98 ft/s
Operating distance: 50 mm 1.97"(50 Hz), 600 mm 23.62" (8 Hz), 1500 mm 59.06"(1 Hz)
*2 Effective length indicates static elimination range at 50 mm 1.97" operating distance.
*3 Overall length includes mounting brackets.

keyence Stock Image
Keyence SJ-M030G Keyence
Sale price $2,351.44
Only 4 units left

Specifications

Model

SJ-M030G

Type

Head

Voltage application method

Pulse AC method

Applied voltage

±5.5 kV

Rated output voltage

±6 kV

Ion balance control method

I.C.C. method

Ion balance

±30 V*1

Supply pressure range

0.2 MPa max.

Control input

Static elimination stop input

Non-voltage input

Control output

Alarm output

NPN open-collector, 100 mA max. (40 V max.)

Ion level alarm output

Condition alarm output

Effective length

164 mm 6.46"*2

Total length

220 mm 8.66"*3

Rating

Power voltage

24 VDC ±10%

Current consumption

450 mA max.

Environmental resistance

Ambient temperature

0 to +40°C 32 to +104°F

Relative humidity

35 to 65%RH (no condensation)

Weight

Approx. 600 g

*1 Measured under the following conditions:
[SJ-M030G/M070G]
Air purge: 3 NL/min per electrode
Down flow: 0.3 m/s 0.98 ft/s
Operating distance: 50 mm 1.97"(50 Hz), 600 mm 23.62" (8 Hz), 1500 mm 59.06"(1 Hz)
[SJ-M030C/M070C]
Air purge: None
Down flow: 0.3 m/s 0.98 ft/s
Operating distance: 50 mm 1.97"(50 Hz), 600 mm 23.62" (8 Hz), 1500 mm 59.06"(1 Hz)
*2 Effective length indicates static elimination range at 50 mm 1.97" operating distance.
*3 Overall length includes mounting brackets.

keyence Stock Image
Keyence SJ-M031C Keyence
Sale price$0.00
Sold Out

Specifications

Model

SJ-M031C

Type

Head

Voltage application method

Pulse AC method

Applied voltage

±5.5 kV

Rated output voltage

±6 kV

Ion balance control method

I.C.C. method

Ion balance

±30 V*1

Control input

Static elimination stop input

Non-voltage input

Control output

Alarm output

NPN open collector 100 mA (40 V or less)

Ion level alarm output

Condition alarm output

Air purge supplied pressure

0.2 MPa or less

Effective length

164 mm 6.457"*2

Total length

220 mm 8.66"*3

Rating

Power voltage

24 VDC ±10 %

Current consumption

450 mA or less

Environmental resistance

Ambient temperature

0 to +40 °C 32 to 104 °F

Relative humidity

35 to 65 % RH (No condensation)

Weight

Approx. 600 g

*1 Operating distance: 50 mm 1.96" (50 Hz), 600 mm 23.62" (8 Hz), 1,500 mm 59.05" (1 Hz). Downward air flow: 0.3 m/s. Air purge: None
*2 Elective length indicates the static elimination rangeat 50 mm 1.97" operating distance.
*3 The overall length includes mounting brackets.

Keyence Stock Image
Keyence SJ-M031G Keyence
Sale price $2,951.05
Only 2 units left

Specifications

Model

SJ-M031G

Type

Head

Voltage application method

Pulse AC method

Applied voltage

±5.5 kV

Rated output voltage

±6 kV

Ion balance control method

I.C.C. method

Ion balance

±30 V*1

Control input

Static elimination stop input

Non-voltage input

Control output

Alarm output

NPN open collector 100 mA (40 V or less)

Ion level alarm output

Condition alarm output

Air purge supplied pressure

0.2 MPa or less

Effective length

164 mm 6.457"*2

Total length

220 mm 8.66"*3

Rating

Power voltage

24 VDC ±10 %

Current consumption

450 mA or less

Environmental resistance

Ambient temperature

0 to +40 °C 32 to 104 °F

Relative humidity

35 to 65 % RH (No condensation)

Weight

Approx. 600 g

*1 Operating distance: 50 mm 1.96" (50 Hz), 600 mm 23.62" (8 Hz), 1,500 mm 59.05" (1 Hz). Downward air flow: 0.3 m/s. Air purge (3 NL/min) /1electrode
*2 Elective length indicates the static elimination rangeat 50 mm 1.97" operating distance.
*3 The overall length includes mounting brackets.

Keyence Stock Image
Keyence SJ-M040 Keyence
Sale price $797.58
In stock, 12 units

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Keyence Stock Image
Keyence SJ-M070 Keyence
Sale price $3,231.59
Only 8 units left

Specifications

Model

SJ-M070

Type

Head

Voltage application method

Pulse AC method

Applied voltage

±5.5 kV

Rated output voltage

±6 kV

Ion balance control method

I.C.C. method

Ion balance

±30 V*1

Supply pressure range

0.2 MPa or less

Control input

Static elimination stop input

Non-voltage input

Control output

Alarm output

NPN open collector 100 mA (40 V or less)

Ion level alarm output

Condition alarm output

Effective length

324 mm12.756"

Total length

380 mm14.961"

Rating

Power voltage

24 VDC ±10 %

Current consumption

450 mA or less

Environmental resistance

Ambient temperature

0 to +40 °C 32 to 104 °F

Relative humidity

35 to 65 % RH (No condensation)

Weight

Approx. 720 g

*1 Please make an inquiry as to the measurement condition.

Recently viewed