Main
| Characteristic | Value(s) |
|---|---|
| range of product | Acti9 |
| product name | Acti9 iIL |
| Product or component type | Modular pilot light |
| Device short name | iIL |
| [Us] rated supply voltage | 110...230 V AC at 50/60 Hz 110...130 V DC |
Complementary
| Characteristic | Value(s) |
|---|---|
| indicator light | 2 LEDs white, service life 100000 h of constant lighting efficiency (consumption 0.6 W) |
| Mounting mode | Fixed |
| Mounting support | Symmetrical DIN rail |
| Comb busbar and distribution block compatibility | Upside: ProDis |
| 9 mm pitches | 2 |
| Height | 82 mm |
| Width | 18 mm |
| Depth | 69.5 mm |
| Colour | White (RAL 9003) |
| Auxiliary connection terminal | Tunnel type terminal 1 cable(s) rigid 0.5 mm² Tunnel type terminal 2 cable(s) rigid 2.5 mm² Tunnel type terminal 1 cable(s) flexible 0.5 mm² Tunnel type terminal 2 cable(s) flexible 2.5 mm² Tunnel type terminal 2 cable(s) flexible with ferrule 2.5 mm² |
| Wire stripping length | 9 mm |
| Tightening torque | 1 N.m |

This Acti 9 RCA remote control system is dedicated to iC60 circuit breakers. It allows remote electrical control OF of circuit breakers with or without Vigi add-on RCD, with or without auxiliary. It allows circuit breaker reseting after tripping, in accordance with safety principles and regulations in force. The width in 9mm pitches is 7. This device controls 3P, 4P installations with Ti24 interface. it allows local control by operating handle. The Ue rated operational voltage is 230VAC. The operating frequency is 50Hz or 60Hz. The circuit is placed in safety configuration by the padlocking device. 2 choices of operation after tripping are possible (A) Enabling of remote circuit breaker resseting or (B) Inhibition of remote resetting. The version with Ti24 interface allows direct interfacing of remote control with programmable logic controller, supervision system, communication device having inputs/outputs in 24VDC (control, OF and SD indications). The version with Ti24 interface allows fast, reliable connection of the remote control to the Acti 9 Smartlink thanks to the prefabricated cables. The version with Ti24 interface allows remote indication by OF potential-free contact, provision of 2 operating modes 1 and 3. The operating temperature is -25°C to + 60°C. The storage temperature is -40°C to + 85°C.
Main
| Characteristic | Value(s) |
|---|---|
| range of product | Acti9 |
| Product or component type | Remote control auxiliary |
| Device short name | RCA iC60 |
| Signal contacts composition | 1 OF volt-free contacts 1 OF Ti24 1 SD Ti24 |
| Signalling circuit voltage | Volt-free contact 24...230 V 0.01â¦1 A AC Ti24 24 V 100 mA DC |
Complementary
| Characteristic | Value(s) |
|---|---|
| Control type | Remote control impulse and maintained 230 V AC 50/60 Hz Remote control maintained Ti24 24 V DC |
| Input current | 5 mA impulse 5 mA maintained 5.5 mA maintained very low voltage |
| Impulse duration | >= 200 ms control circuit |
| Response time | < 500 ms |
| [Us] rated supply voltage | 230 V AC 50/60 Hz |
| Power consumption in W | 1 W |
| [Ui] rated insulation voltage | 400 V |
| [Uimp] rated impulse withstand voltage | 6 kV |
| Value of setting | Auto: remote control authorized Off: remote control inhibited Mode 1: central control Mode 3: central control and local override Position A: reclosing authorized after tripping Position B: reclosing inhibited after tripping |
| Local signalling | Flashing green LED: ready to operate Flashing orange LED: not operational |
| Mounting mode | Fixed |
| Mounting support | DIN rail |
| Comb busbar and distribution block compatibility | NO |
| 9 mm pitches | 7 |
| Height | 93 mm |
| Width | 63 mm |
| Depth | 75.5 mm |
| Product weight | 430 g |
| Colour | White |
| Electrical durability | 10000 cycles |
| Mechanical durability | 10000 cycles |
| Provision for padlocking | Padlockable |
| Wire stripping length | Power supply: 10 mm for bottom connection Input: 10 mm for bottom connection Output: 8 mm for top connection Ti24 interface: 10 mm for terminal connection |
| Tightening torque | Auxiliary output: 0.7 N.m Auxiliary supply: 1 N.m Auxiliary input: 1 N.m |
| Physical interface | Ti24 |
| Range compatibility | Acti 9 Acti9 iC60 Acti 9 Acti9 iC65 Acti 9 iMDU voltage adaptor Modicon PLC |
| Product compatibility | 3P or 4P iC60 3P or 4P iC65 iMDU PLC |

This Acti9 iPRD-DC 40r direct current surge arresters protects 2P photovoltaic installations. It allows quick replacement of damaged cartridges. The Itotal discharge current is 40kA. The In nominal discharge current is 15kA. This Type 2 device is recommended to protect against indirect lightning strikes. The surge arresters with r indication have remote transfer of the information Cartridge to be replaced. It can be turned over to allow the phase/neutral/earth cables to enter through either the top or the bottom. The Uc maximum continuous operating voltage is 800VDC. The Up protection level is 3kV in differential mode and in common mode. The Ue rated operational voltage is 800VDC +/- 10%. The product colour is white (RAL9003). The dimensions are (W) 54mm x (H) 85mm x (D) 69mm. The width in 9mm pitches is 4. The weight is 400g. The degree of protection is IP20 and IP40 in modular enclosure. The operating temperature is -25°C to 60°C. The storage temperature is -40°C to 85°C. This product complies with UTE C 61470-51 and EN 50539-11:2013 standards.
Main
| Characteristic | Value(s) |
|---|---|
| range of product | Acti9 |
| product name | Acti9 iPRD PV-DC |
| Device short name | iPRD PV-DC |
| Product or component type | Surge arrester with pluggable cartridge |
| Poles description | 2P |
| Output type | Contact (volt-free) |
| Signal contacts composition | 1 SD (1 C/O) |
| Surge arrester type | Electrical distribution network |
| Uoc stc: Maximum open circuit voltage of PV generator in standard test condition | 666 V |
Complementary
| Characteristic | Value(s) |
|---|---|
| Surge arrester class type | Type 2 |
| Surge arrester technology | MOV |
| [Ue] rated operational voltage | 800 V +/- 10 % DC |
| [In] nominal discharge current | 15 kA |
| [Imax] maximum discharge current | 40 kA |
| [Ucpv] maximum continuous operating voltage | Differential mode: 800 V L+/L- Common mode: 800 V L+/PE Common mode: 800 V L-/PE |
| Maximum [Up] voltage protection level | Differential mode <3 kV type 2 L+/L- Common mode <3 kV type 2 L+/PE Common mode <3 kV type 2 L-/PE |
| Disconnector device type | Integrated disconnector |
| Local signalling | White/red flag |
| Signalling circuit voltage | AC: 250 V 50/60 Hz |
| Signalling output current | 0.25 A |
| Mounting mode | Clip-on |
| Mounting support | DIN rail |
| 9 mm pitches | 6 |
| Height | 85 mm |
| Width | 54 mm |
| Depth | 69 mm |
| Product weight | 400 g |
| Colour | White (RAL 9003) |
| Response time | <= 25 ns |
| Connections - terminals | Tunnel type terminal 2.5â¦25 mm² rigid Tunnel type terminal 2.5â¦16 mm² flexible Tunnel type terminal 2.5â¦16 mm² flexible stranded |
| Wire stripping length | 14 mm |
| Tightening torque | 3.5 N.m |

This Acti9 iC40N product is a low voltage miniature circuit breaker (MCB). It is a 1P+N circuit breaker with 1 protected pole and 20A In rated current and C tripping curve. The rated short circuit breaking capacity goes up to 10kA at 230VAC conforming to EN/IEC 60947-2 standard and 6000A at 230VAC conforming to EN/IEC 60898-1 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. This miniature circuit breaker combines functions of circuit protection against short circuit and overload current, control and isolation. The installation and cabling are simplified with clip on function as well as ease of maintenance. It has an electrical endurance going up to 20000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 230VAC. The Ui rated insulation voltage is 400VAC. The Uimp rated impulse withstand voltage is 4kV. The operating frequency is 50Hz or 60Hz. It can be mounted on DIN rail for modular installation. Its width is 2 pitches of 9mm. Pollution degree is 3. The product colour is white (RAL9003). The dimensions are (W) 18mm x (H) 85mm x (D) 74mm. The weight is 120g. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is -25°C to 70°C. The storage temperature is -40°C to 85°C.
Main
| Characteristic | Value(s) |
|---|---|
| Range | Acti9 |
| product name | Acti9 iC40 |
| Product or component type | Miniature circuit-breaker |
| Device short name | iC40N |
| Device application | Distribution |
| Poles description | 1P + N |
| Number of protected poles | 1 |
| Neutral position | Left |
| [In] rated current | 20 A |
| Network type | AC |
| Trip unit technology | Thermal-magnetic |
| Curve code | C |
| Breaking capacity | 10 kA Icu at 230 V AC 50/60 Hz conforming to EN/IEC 60947-2 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1 |
| Suitability for isolation | Yes conforming to EN/IEC 60947-2 |
| Quality labels | AENOR RCM IMQ OVE |
Complementary
| Characteristic | Value(s) |
|---|---|
| Network frequency | 50/60 Hz |
| [Ue] rated operational voltage | 230 V AC 50/60 Hz |
| Magnetic tripping limit | 5...10 x In conforming to EN/IEC 60898-1 8 x In +/- 20 % conforming to EN/IEC 60947-2 |
| [Ics] rated service breaking capacity | 6000 A 100 % x Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1 7.5 kA 75 % x Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60947-2 |
| Limitation class | 3 conforming to EN/IEC 60898-1 |
| [Ui] rated insulation voltage | 400 V AC 50/60 Hz conforming to EN/IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 4 kV conforming to EN/IEC 60947-2 |
| Contact position indicator | Yes |
| control type | Toggle |
| Local signalling | ON/OFF indication Trip indicator |
| Mounting mode | Clip-on |
| Mounting support | DIN rail |
| 9 mm pitches | 2 |
| Height | 85 mm |
| Width | 18 mm |
| Depth | 74 mm |
| Product weight | 120 g |
| Colour | White |
| Mechanical durability | 20000 cycles |
| Electrical durability | 20000 cycles |
| Locking options description | Padlocking device |
| Connections - terminals | Tunnel type terminals top or bottom 1â¦10 mm² flexible Tunnel type terminals top or bottom 1â¦16 mm² rigid |
| Wire stripping length | 14 mm for top or bottom connection |
| Tightening torque | 2 N.m top or bottom |
| Earth-leakage protection | Separate block |

This Acti9 iID is a modular and reliable residual current circuit breaker (RCCB). It is a 4P circuit breaker with 25A In rated current, 30mA earth leakage sensitivity and AC type protection class. This product protects against electrical shock by direct or indirect contact and fire hazards. It performs the function of disconnection of electrical circuits in case of earth fault. Its unique Visitrip indicator reduces intervention time by showing the faulty device with a mechanical indicator on front face. This product also has a VisiSafe window with a green strip on the toggle indicating full opening of the poles allowing downstream maintenance This product is compliant with EN/IEC 61008-1 standard. The (Im/IÎm) rated breaking and making short circuit capacity is 1500A. The (Inc/IÎc) conditional rated short circuit current is 10kA. It has an electrical endurance going up to 15000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 380VAC to 415VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The frequency is 50Hz or 60Hz. It is DIN rail mountable. The width in 9mm pitches is 8. The product colour is white (RAL9003). The dimensions are (W) 72mm x (H) 91mm x (D) 73.5mm. The weight is 0.37kg. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is from -5°C to 60°C. The storage temperature is from -40°C to 85°C.
Main
| Characteristic | Value(s) |
|---|---|
| Range | Acti9 |
| product name | Acti9 iID |
| Product or component type | Residual current circuit breaker (RCCB) |
| Device short name | iID |
| Poles description | 4P |
| Neutral position | Left |
| [In] rated current | 25 A |
| Network type | AC |
| Earth-leakage sensitivity | 30 mA |
| Earth-leakage protection time delay | Instantaneous |
| Earth-leakage protection class | Type AC |
Complementary
| Characteristic | Value(s) |
|---|---|
| Device location in system | Outgoer |
| Network frequency | 50/60 Hz |
| [Ue] rated operational voltage | 380...415 V AC 50/60 Hz |
| Residual current tripping technology | Voltage independent |
| Rated breaking and making capacity | Idm 1500 A Im 1500 A |
| Rated conditional short-circuit current | 10 kA |
| [Ui] rated insulation voltage | 500 V AC 50/60 Hz |
| [Uimp] rated impulse withstand voltage | 6 kV |
| Surge current | 250 A |
| Contact position indicator | Yes |
| control type | Toggle |
| Mounting mode | Clip-on |
| Mounting support | DIN rail |
| 9 mm pitches | 8 |
| Height | 91 mm |
| Width | 72 mm |
| Depth | 73.5 mm |
| Product weight | 0.37 kg |
| Colour | White |
| Mechanical durability | 20000 cycles |
| Electrical durability | AC-1: 15000 cycles |
| Locking options description | Padlocking device |
| Connections - terminals | Single terminal top or bottom 1â¦35 mm² rigid Single terminal top or bottom 1â¦25 mm² flexible Single terminal top or bottom 1â¦25 mm² flexible with ferrule |
| Wire stripping length | 14 mm for top or bottom connection |
| Tightening torque | 3.5 N.m top or bottom |

This Acti9 C60H-DC is a low voltage direct current miniature circuit breaker (MCB). It has 2P, rated current 1A and C tripping curve. The rated short circuit breaking capacity goes up to 20kA at 220VDC conforming to GB 14048.2 standard and 20kA at 220VDC conforming to GB 14048.2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. This miniature circuit breaker protects circuit against short circuit and overload current. It offers VisiTrip for safety during maintenance and VisiSafe to reduce intervention time. The Acti9 C60H-DC is used in direct current circuit (industrial control and automation, transport, renewable energy). This device is dedicated to industrial control, automations, transport and renewable energy applications. It has an electrical endurance going up to 3000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 500VDC. The Ui rated insulation voltage is 500VDC. The Uimp rated impulse withstand voltage is 6kV. The operating frequency is 50Hz or 60Hz. It is DIN rail mountable. Its width is 4 pitches of 9mm. Pollution degree is 3. Overvoltage category is IV. The product colour is white (RAL9003). The weight is 0.256kg. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is -25°C to 70°C. The storage temperature is -40°C to 85°C.
Main
| Characteristic | Value(s) |
|---|---|
| Range | Acti9 |
| product name | Acti9 C60H-DC |
| Product or component type | Miniature circuit-breaker |
| Device short name | C60H-DC |
| Device application | Distribution |
| Poles description | 2P |
| Number of protected poles | 2 |
| [In] rated current | 1 A at 25 °C |
| Network type | DC |
| Trip unit technology | Thermal-magnetic |
| Curve code | C |
| Breaking capacity | 10 kA Icu at 440 V DC conforming to EN 60947-2 10 kA Icu at 440 V DC conforming to IEC 60947-2 6 kA Icu at 500 V DC conforming to EN 60947-2 6 kA Icu at 500 V DC conforming to IEC 60947-2 20 kA Icu at 220 V DC conforming to GB 14048.2 20 kA Icu at 220 V DC conforming to IEC 60947-2 20 kA Icu at 250 V DC conforming to GB 14048.2 20 kA Icu at 250 V DC conforming to IEC 60947-2 |
| Utilisation category | Category A conforming to EN 60947-2 Category A conforming to IEC 60947-2 |
| Suitability for isolation | Yes conforming to IEC 60947-2 Yes conforming to EN 60947-2 |
| Standards | EN 60947-2 IEC 60947-2 |
Complementary
| Characteristic | Value(s) |
|---|---|
| Network frequency | 50/60 Hz |
| [Ue] rated operational voltage | 500 V DC |
| [Ics] rated service breaking capacity | 15 kA 75 % conforming to EN 60947-2 - 220 V DC 15 kA 75 % conforming to IEC 60947-2 - 220 V DC 15 kA 75 % conforming to EN 60947-2 - 250 V DC 15 kA 75 % conforming to IEC 60947-2 - 250 V DC 4.5 kA 75 % conforming to EN 60947-2 - 500 V DC 4.5 kA 75 % conforming to IEC 60947-2 - 500 V DC 7.5 kA 75 % conforming to EN 60947-2 - 440 V DC 7.5 kA 75 % conforming to IEC 60947-2 - 440 V DC |
| [Ui] rated insulation voltage | 500 V DC conforming to IEC 60947-2 500 V DC conforming to EN 60947-2 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to EN 60947-2 6 kV conforming to IEC 60947-2 |
| Contact position indicator | Yes |
| control type | Toggle |
| Local signalling | ON/OFF indication |
| Mounting mode | Fixed |
| Mounting support | 35 mm symmetrical DIN rail |
| Comb busbar and distribution block compatibility | Top or bottom: standard |
| 9 mm pitches | 4 |
| Product weight | 0.256 kg |
| Colour | White |
| Mechanical durability | 20000 cycles |
| Electrical durability | 3000 cycles L/R = 2 ms |
| Provision for padlocking | Padlockable |
| Locking options description | In position O |
| Tightening torque | Power circuit: 2.5 N.m top or bottom |
| Earth-leakage protection | Without |

This PowerTag Energy P63 3P+N Top is a wireless communication energy sensor. It is dedicated to Acti9 and Multi9 3P+N PhaseNeutral devices with 9mm pitch between phase and neutral, rating less than or equal 63A. It has to be associated with a concentror or a gateway to provide circuit monitoring and diagnosis down to load level. It is designed specifically for Energy Management, Load Monitoring and Power Availability applications. It incorporates accurate real-time measurements of active energy, active power, current, voltage and power factor. In case of power outage, it sends a voltage loss alarm and the current-per-phase value before being de-energized. PowerTag Energy 63A complies with IEC 61557-12 standard. It is a PMD-I/DD/K55/1. The Performance category is Class 1. The Imax Maximum current is 63A. The Ib Base current is 10A. The Saturation current is 130A. The Ist Starting current is 40mA. The Un rated voltage are Phase-to-neutral 220VAC to 240VAC +/- 20% and Phase-to-phase 380VAC to 415VAC +/- 20%. The maximum consumption is below or equal to 2VA. It can be only mounted on the top of the protective device. The product color is white (RAL9003). The weight is 48g. The degree of protection is IP20 and IK05 The operating temperature is between -25°C to +60°C. The Storage temperature is between -40°C to +85°C.
Main
| Characteristic | Value(s) |
|---|---|
| Range of product | PowerLogic |
| product name | PowerTag A9 P63 |
| Product or component type | Energy sensor |
| Poles | 3P + N |
| Maximum current [Imax] | 63 A |
| [Ib] Basic current | 10 A |
| Starting current | 40 mA |
| Saturation current | 130 A |
| Product specific application | Load monitoring Overload alarm Circuit monitoring Cost allocation Energy management |
| Concentrator compatibility | Acti9 Smartlink SI B Acti9 Smartlink SI D Acti9 PowerTag Link C Acti9 PowerTag Link Acti9 PowerTag Link HD Wiser IP module EcoStruxure Panel Server Universal EcoStruxure Panel Server Advanced PrismaSet Active |
| Application | Buildings: breaker voltage monitoring Buildings: cost allocation Buildings: overload alarm |
| Range compatibility | Multi9 Multi9 N40 Vigi Acti 9 Acti9 C40 Vigi Acti 9 Acti9 iDPN Acti 9 Acti9 iC40 Multi9 Multi9 N40 Acti 9 Acti9 iCV40 Acti 9 Acti9 C40 Acti 9 Acti9 DT40 Acti 9 Acti9 DT40 Vigi Acti 9 Acti9 iDPN Vigi |
| Type of measurement | Active power Power factor Active energy Voltage Current |
| Accuracy class | Class 1 current conforming to IEC 61557-12 Class 0.5 voltage conforming to IEC 61557-12 Class 1 active power conforming to IEC 61557-12 Class 1 active energy conforming to IEC 61557-12 Class 1 power factor conforming to IEC 61557-12 |
| Mounting location | Top |
| Mounting support | On circuit breaker |
| Connection pitch | 9 mm Ph/N 18 mm Ph/Ph |
| Product destination | Switchboard |
| Event management | Voltage loss with measured current at voltage loss |
| Transmission support medium | Radio frequency 2.4â¦2.4835 GHz conforming to IEEE 802.15.4 |
| Emission power | 10 mW |
Complementary
| Characteristic | Value(s) |
|---|---|
| Form factor | PhaseNeutral |
| Mounting mode | By screws (terminals) |
| Electrical connection (voltage sensing & power supply) | Connector tooth |
| Cable cross section | 1 rigid cable 1.5â¦16 mm² 2 stranded cable 1.5â¦2.5 mm² 2 rigid cable 1.5â¦2.5 mm² 1 stranded cable 1.5â¦16 mm² |
| supply voltage | 220...240 V AC, +/- 20 %, between phase and neutral 380...415 V AC, +/- 20 %, between phases |
| Network frequency | 50 Hz 60 Hz |
| Maximum power consumption | 2 VA |
| Standards | IEC 61557-12 IEC 61010-1 IEC 61010-2-030 IEC 61326-1 ETSI EN 300 328 ETSI EN 301 489-1 |
| Height | Sensor element: 19.5 mm Base unit: 8 mm |
| Width | Sensor element: 54 mm Base unit: 54 mm |
| Depth | Sensor element: 43 mm Base unit: 48 mm |
| Product weight | 48 g |
| Colour | White (RAL 9003) |
| Compatibility code | PowerTag A9 P63 |

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

This Acti9 iQuick PRD8r surge arrester protects 3P+N residential and larger buildings installations against indirect transient overvoltages. This Type 2 or Type 3 device autoprotected by integrated circuit-breaker is recommended for moderate risk level in secondary panel board. It offers remote reporting of the "cartridge must be changed" message. This prewired surge arrester allows quick replacement of withdrawable cartridges when they are damaged. It incorporates its end of life safety disconnector. The Isc integrated breaking capacity is 25kA. This Acti9 iQuick PRD8r is compatible with TT and TN-S earthing system. The Imax maximum discharge current is 8kA. The In nominal discharge current is 2kA. The Uc maximum continuous operating voltage in differential mode (between phase and neutral) is 350VAC. The Uc maximum continuous operating voltage in common mode is 264VAC between neutral and earth, and is 350VAC between phase and earth. The Up Voltage protection level in type 2 is 1.5kV in common mode (L/PE or N/PE), and is 1.2kV in differential mode (L/N). The Up Voltage protection level in type 3 is 1.4kV in common mode (L/PE), 1.5kV in common mode (N/PE), and 1.4kV in differential mode (L/N). The Un rated service voltage is 230VAC or 400VAC. The operating frequency is 50Hz or 60Hz. The dimensions are (W) 131.5mm x (H) 103.8mm x (D) 75.9mm. The width in 9mm pitches is 15. The weight is 810g. The degree of protection is IP20 and IP40 in modular enclosure. The operating temperature is -25°C to +60°C. The storage temperature is -40°C to +85°C. This product complies with IEC/EN 60947-5-1 and EN 61643-11: 2012 and IEC 61643-11: 2011 Type 2 standards.
Main
| Characteristic | Value(s) |
|---|---|
| Range of product | IQuick PRD |
| range of product | Acti9 |
| product name | Acti9 iQuick PRD |
| Product or component type | Surge arrester with pluggable cartridge |
| Device short name | iQuick PRD8r |
| Device application | Distribution |
| Standards | EN 61643-11:2012 IEC 61643-11:2011 |
| Product certifications | CE |
| Quality labels | KEMA-KEUR NF |
| Poles description | 3P + N |
| Remote signalling | With |
| Signal contacts composition | 1 SD (1 C/O) |
| Surge arrester type | Electrical distribution network |
| Earthing system | TT TN-S |
Complementary
| Characteristic | Value(s) |
|---|---|
| Surge arrester class type | Type 2 + 3 |
| Surge arrester technology | MOV + GDT |
| [Ue] rated operational voltage | 230/400 V AC (+/- 10 %) at 50/60 Hz |
| Nominal discharge current | Common mode: 2 kA (L/PE) Common mode: 2 kA (N/PE) Differential mode: 2 kA (L/N) |
| Maximum discharge current | Common mode: 8 kA L/PE Common mode: 8 kA N/PE Differential mode: 8 kA L/N |
| [Uoc] open circuit voltage | 10 kV type 3 common mode L/PE 10 kV type 3 common mode N/PE 10 kV type 3 differential mode L/N |
| [Uc] maximum continuous operating voltage | Common mode: 264 V N/PE Common mode: 350 V L/PE Differential mode: 350 V L/N |
| Maximum [Up] voltage protection level | Common mode <1.5 kV type 2 L/PE Common mode <1.7 kV type 2 N/PE Differential mode <1.2 kV type 2 L/N Common mode <1.4 kV type 3 L/PE Differential mode <1.4 kV type 3 L/N Common mode <1.5 kV type 3 N/PE |
| Disconnector device type | Integrated circuit breaker - Icu 25 kA |
| Signalling circuit voltage | 2 A/250 V AC 50/60 Hz |
| Mounting mode | Clip-on (DIN rail) |
| 9 mm pitches | 14.6 |
| Height | 94 mm |
| Width | 131.5 mm |
| Depth | 75.9 mm |
| Product weight | 0.84 kg |
| Colour | White (RAL 9003) |
| Connections - terminals | Tunnel type terminal (downside) 2.5â¦25 mm² Tunnel type terminal (upside) 2.5â¦25 mm² |
| Tightening torque | 2.5 N.m |
| Compatibility code | IQuick PRD8r |

Main
| Characteristic | Value(s) |
|---|---|
| Device application | Distribution Control |
| Range | Acti9 |
| product name | Reflex iC60 |
| Device short name | Reflex iC60N |
| Product or component type | Integrated control circuit breaker |
| Poles description | 3P |
| Number of protected poles | 3 |
| Network type | AC |
| Trip unit technology | Thermal-magnetic |
| Curve code | C |
Complementary
| Characteristic | Value(s) |
|---|---|
| [In] rated current | 63 A |
| Network frequency | 50/60 Hz |
| Breaking capacity code | N |
| Breaking capacity | 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 |
| [Ui] rated insulation voltage | 500 V AC |
| Contact position indicator | Yes |
| control type | Remote control by continuous command ON/OFF button Remote control by pulse Toggle |
| Control signal type | Impulse Maintained Maintained very low voltage |
| Local signalling | Flashing LED: device tripped Flashing LED: device overheat Red LED: fault Green LED: device ON Flashing LED: device ready |
| [Uc] control circuit voltage | 230 V AC 50/60 Hz 24 V AC 50/60 Hz 48 V AC 50/60 Hz 24 V DC 48 V DC |
| [Us] rated supply voltage | 230 V AC at 50/60 Hz |
| Mounting mode | Fixed |
| Mounting support | 35 mm symmetrical DIN rail |
| 9 mm pitches | 11 |
| Height | 84 mm |
| Width | 99 mm |
| Depth | 77 mm |
| Colour | White |
| Mechanical durability | 50000 cycles |
| Electrical durability | AC-1: 50000 cycles AC 50 Hz |
| Provision for padlocking | Padlockable |
| Locking options description | Padlock in OFF position |
| Earth-leakage protection | Separate block |
| Product compatibility | With PLC |

This Acti9 OF+SD/OF electric auxiliary is a double open/closed or fault indicator contact. It is dedicated to C60, C40, C120, C40, iID, DT40, iDPN Vigi, SW60-DC, iTG40 products. It comes with 1 changeover contact indicating the open or closed position (OF). It provides a remote position open/close and/or fault tripping indication of the associated device. It is a two-in-one product. The choice of OF+SD or OF+OF contact is made via the selector switch on front face. There is a mechanical state indicator and a test function button on the front face. The Ue rated operational voltage is 24VAC to 415VAC or 24VDC to 130VDC. The operating frequency is 50Hz or 60Hz. The Ie rated operational current is 6A under 24VDC, 2A under 48VDC, 1.5A under 60VDC, 1A under 130VDC. The Ie rated operational current is 6A under 24VAC to 240VAC, 3A under 415VAC. The width in 9mm pitches is 1. The product color is white (RAL9003). The dimensions are (W) 9mm x (H) 85.3mm x (D) 73.5mm. Product weight is 30g. The degree of protection is IP20 at terminals and IP40 in enclosure. The operating temperature is -25°C to +50°C. The storage temperature is -40°C to +85°C. This product complies with EN/IEC 60947-5-1 standard.
Main
| Characteristic | Value(s) |
|---|---|
| range of product | Acti9 |
| Product or component type | OC contact |
| Device short name | OF |
| Signal contacts composition | 1 C/O |
| [In] rated current | AC-12 3 A at 380...415 V, AC 50/60 Hz AC-12 6 A at 220...240 V, AC 50/60 Hz DC-12 1 A at 130 V, DC DC-12 1.5 A at 60 V, DC DC-12 2 A at 48 V, DC DC-12 6 A at 24 V, DC |
| [Uc] control circuit voltage | 24...415 V AC 50/60 Hz 24...130 V DC |
| 9 mm pitches | 1 |
| Standards | EN/IEC 60947-5-1 |
| Product certifications | ASEFA KEMA LCIE ASTA |
Complementary
| Characteristic | Value(s) |
|---|---|
| Mounting mode | Fixed |
| Mounting support | DIN rail |
| Comb busbar and distribution block compatibility | Top: YES |
| Height | 85.3 mm |
| Width | 9 mm |
| Depth | 73.5 mm |
| Product weight | 30 g |
| Colour | White |
| Connections - terminals | Screw clamp terminal (bottom) 2 cable(s) 1.5 mm² - flexible Screw clamp terminal (bottom) 1 cable(s) 0.5â¦2.5 mm² - rigid Screw clamp terminal (bottom) 2 cable(s) 1.5 mm² - flexible with ferrule |
| Wire stripping length | 9 mm |
| Tightening torque | 1 N.m |