Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Harmony iPC |
| Terminal type | Touchscreen display |
| Product or Component Type | Flat screen |
Complementary
| Characteristic | Value(s) |
|---|---|
| Display resolution | 1024 x 768 pixels XGA |
| Display type | Colour TFT LCD |
| Luminance | 37.2 fc (400 cd/m²) 9.3 fc (100 cd/m²) |
| Touch panel | Multi touch analogue resistive 1000000 cycles |
| Function Available | Brightness sensor |
| Display size | 15 inch |
| Aspect ratio | 4:3 |
| [Us] rated supply voltage | 12...24 V DC power supply |
| Display colour | 16 million colours |
| Provided equipment | 1 cable 16.4 ft (5 m) DVI-D 1 cable 16.4 ft (5 m) USB type A 1 USB cable mini B USB 2.0 |
| Device mounting | Flush |
| Cut-out dimensions | 383.5 (+ 1/- 0) x 282.5 (+ 1/- 0) mm |
| Width | 15.6 in (397 mm) |
| Height | 11.7 in (296 mm) |
| Product Weight | 11.5 lb(US) (5.2 kg) |


Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Harmony iPC |
| Terminal type | Touchscreen display |
| Product or Component Type | Flat screen |
Complementary
| Characteristic | Value(s) |
|---|---|
| Display resolution | 1024 x 768 pixels XGA |
| Display type | Colour TFT LCD |
| Luminance | 9.3 fc (100 cd/m²) 37.2 fc (400 cd/m²) |
| Touch panel | Multi touch analogue resistive 1000000 cycles |
| Function Available | Brightness sensor |
| Display size | 12.1 inch |
| Aspect ratio | 4:3 |
| [Us] rated supply voltage | 12...24 V DC power supply |
| Display colour | 16 million colours |
| Provided equipment | 1 cable 16.4 ft (5 m) DVI-D 1 cable 16.4 ft (5 m) USB type A 1 USB cable mini B USB 2.0 |
| Device mounting | Flush |
| Cut-out dimensions | 301.5 (+ 1/- 0) x 227.5 (+ 1/- 0) mm |
| Width | 12.4 in (315 mm) |
| Height | 9.5 in (241 mm) |
| Product Weight | 8.6 lb(US) (3.9 kg) |

This EcoStruxure EV charging Expert is an EV charger controller providing a dynamic load management for EVlink Pro AC and EVlink Pro DC charging stations. It is recommended for commercial and industrial buildings as well as for fleets depot to optimize the impact of consumption of EV charging infrastructure on an electrical installation. The capacity is to control up to 15 EV charging stations, combined in up to 20 electrical zones with 4 zone levels. This capacity can be upgraded via software license. There is also a possibility to use different functionalities for an efficient EV charging infrastructure operation. Time-of-use electricity tariff can be scheduling to limit EV charging when electricity price is high, and to maximize it when it is low. VIP user badges and charging stations will undergo load-shedding, only in emergency when absolutely necessary to maintain service continuity, as they have priority over other users to charge their electric vehicles. Registering and download of EV charging transactions for analytics, cost allocation or invoicing is possible. There are API for integration capabilities to Building Energy Management System (BEMS). There is priorization of PV produced energy for EV charging. It can be installed in indoor enclosure mounted on a DIN rail. Itâs supplied via external 24Vdc power supply. The IP degree of protection is IP40. The operating temperature is between 0°C and 50°C. The storage temperature is between -20°C and 60°C. The dimensions are (W) 157mm x (H) 150mm x (D) 46mm. The LAN connection network with the EVlink chargers is established through Ethernet connection via RJ45 port and External 8 port switch. It uses OCPP 1.6 Json protocol for communication with EVlink chargers. An external Building Power meter can be also connected in the LAN network. For communication with Charging Point Operatorâs (CPOs), Charging Station Management System (CSMS) uses OCPP 1.6 Json protocol via external 4G modem. The EV charger controller has the CE, UK and RMC certification.
Main
| Characteristic | Value(s) |
|---|---|
| Range | EcoStruxure EV Charging Expert |
| product name | EcoStruxure EV Charging Expert |
| Product or component type | EV charge controller |
| Type of installation | Indoor |
Complementary
| Characteristic | Value(s) |
|---|---|
| Installed device | Modem 3G/4G (to be ordered separately) Meter device (to be ordered separately) |
| Range compatibility | EVlink EVlink Pro AC EVlink EVlink Pro DC EVlink EVlink Smart Wallbox EVlink EVlink parking EVlink EVlink City |
| Device application | To manage the overall energy allocated to each vehicle |
| Mounting mode | Wall mount |
| Mounting support | Rail |
| Mounting position | Horizontal/vertical |
| load management | Dynamic |
| max managed charging stations | 15 charging stations |
| max managed charging points | 30 charge points |
| max nb of zone levels | 4 |
| max nb of zones | 20 |
| functions selection | With priority charging profile With time-of-use settings With PV integration With BEMS integration via API With authentication via badges With transaction logs |
| Communication interface | Ethernet RJ45 to connect device to charging station Ethernet RJ45 Cat.6 to connect device to charging station Modem to connect device to central management system |
| Communication service | Web server for OCPP 1.6 Via Modem |
| OCPP version | JSON |
| [Us] rated supply voltage | 12...24 V DC |
| Power consumption in W | 16 W |
| Input type | Energy meter |
| Electromagnetic compatibility | Conducted and radiated emissions class A conforming to EN 55022 |
| Height | 150 mm |
| Width | 157 mm |
| Depth | 46 mm |
| Product weight | 1 kg |
| Standards | EN/IEC 61131-2 EN 55011 EN/IEC 61000-6-4 |
| Product certifications | CE EAC RCM |
| Targeted country | All |
| Services | Commercial service plan 0...50 °C |

Main
| Characteristic | Value(s) |
|---|---|
| Range | EcoStruxure EV Charging Expert |
| product name | EcoStruxure EV Charging Expert |
| Product or component type | EV charge controller |
| Type of installation | Indoor |
Complementary
| Characteristic | Value(s) |
|---|---|
| Installed device | Modem 3G/4G (to be ordered separately) |
| Range compatibility | EVlink EVlink Smart Wallbox EVlink EVlink parking EVlink EVlink City |
| Device application | To manage the overall energy allocated to each vehicle |
| Mounting mode | Wall mount |
| Mounting support | Rail |
| Mounting position | Horizontal/vertical |
| load management | Static |
| max managed charging stations | 15 charging stations |
| max managed charging points | 30 charge points |
| max nb of zone levels | 1 |
| max nb of zones | 1 |
| functions selection | Without priority charging profile Without time-of-use settings |
| Communication interface | Ethernet RJ45 to connect device to charging station Ethernet RJ45 Cat.6 to connect device to charging station Modem to connect device to central management system |
| Communication service | Web server for OCPP 1.6 Via Modem |
| OCPP version | JSON |
| [Us] rated supply voltage | 12...24 V DC |
| Power consumption in W | 16 W |
| Electromagnetic compatibility | Conducted and radiated emissions class A conforming to EN 55022 |
| Height | 150 mm |
| Width | 157 mm |
| Depth | 46 mm |
| Product weight | 1 kg |
| Standards | EN/IEC 61131-2 EN 55011 EN/IEC 61000-6-4 |
| Product certifications | CE EAC RCM |
| Targeted country | All |
| Services | Commercial service plan 0...50 °C |

This EcoStruxure EV charging Expert is an EV charger controller providing a dynamic load management for EVlink Pro AC and EVlink Pro DC charging stations. It is recommended for commercial and industrial buildings as well as for fleets depot to optimize the impact of consumption of EV charging infrastructure on an electrical installation. The capacity is to control up to 50 EV charging stations, combined in up to 20 electrical zones with 4 zone levels. This capacity can be upgraded via software license. There is also a possibility to use different functionalities for an efficient EV charging infrastructure operation. Time-of-use electricity tariff can be scheduling to limit EV charging when electricity price is high, and to maximize it when it is low. VIP user badges and charging stations will undergo load-shedding, only in emergency when absolutely necessary to maintain service continuity, as they have priority over other users to charge their electric vehicles. Registering and download of EV charging transactions for analytics, cost allocation or invoicing is possible. There are API for integration capabilities to Building Energy Management System (BEMS). There is priorization of PV produced energy for EV charging. It can be installed in indoor enclosure mounted on a DIN rail. Itâs supplied via external 24Vdc power supply. The IP degree of protection is IP40. The operating temperature is between 0°C and 50°C. The storage temperature is between -20°C and 60°C. The dimensions are (W) 157mm x (H) 150mm x (D) 46mm. The LAN connection network with the EVlink chargers is established through Ethernet connection via RJ45 port and External 8 port switch. It uses OCPP 1.6 Json protocol for communication with EVlink chargers. An external Building Power meter can be also connected in the LAN network. For communication with Charging Point Operatorâs (CPOs), Charging Station Management System (CSMS) uses OCPP 1.6 Json protocol via external 4G modem. The EV charger controller has the CE, UK and RMC certification.
Main
| Characteristic | Value(s) |
|---|---|
| Range | EcoStruxure EV Charging Expert |
| product name | EcoStruxure EV Charging Expert |
| Product or component type | EV charge controller |
| Type of installation | Indoor |
Complementary
| Characteristic | Value(s) |
|---|---|
| Installed device | Modem 3G/4G (to be ordered separately) Meter device (to be ordered separately) |
| Range compatibility | EVlink EVlink Pro AC EVlink EVlink Pro DC EVlink EVlink Smart Wallbox EVlink EVlink parking EVlink EVlink City |
| Device application | To manage the overall energy allocated to each vehicle |
| Mounting mode | Wall mount |
| Mounting support | Rail |
| Mounting position | Horizontal/vertical |
| load management | Dynamic |
| max managed charging stations | 50 charging stations |
| max managed charging points | 100 charge points |
| max nb of zone levels | 4 |
| max nb of zones | 20 |
| functions selection | With priority charging profile With time-of-use settings With PV integration With BEMS integration via API With authentication via badges With transaction logs |
| Communication interface | Ethernet RJ45 Cat.6 to connect device to charging station Ethernet RJ45 to connect device to charging station Modem to connect device to central management system |
| Communication service | Web server for OCPP 1.6 Via Modem |
| OCPP version | JSON |
| [Us] rated supply voltage | 12...24 V DC |
| Power consumption in W | 16 W |
| Input type | Energy meter |
| Electromagnetic compatibility | Conducted and radiated emissions class A conforming to EN 55022 |
| Height | 150 mm |
| Width | 157 mm |
| Depth | 46 mm |
| Product weight | 1 kg |
| Standards | EN/IEC 61131-2 EN 55011 EN/IEC 61000-6-4 |
| Product certifications | CE EAC RCM |
| Targeted country | All |
| Services | Commercial service plan 0...50 °C |



Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Harmony iPC |
| Device short name | Modular BOX PC Performance |
| Product or Component Type | Modular box PC |
| Range Compatibility | IDisplay Modular Display HMIDM |
| Accessory / separate part destination | PC panel HMIDM modular display |
| Chipset type | Intel QM87 |
| Software package | Node-RED and system nodes restore IIoT Wiring Operating System Restore McAfee white listing installer cyber security license not included EcoStruxture secure connect advisor annual subscription cyber security license not included EcoStruxure Operator Terminal Expert run time HMI license not included EcoStruxure machine SCADA expert run time HMI/SCADA on configured offer only EcoStruxure augmented operator advisor server augmented operator license not included |
Complementary
| Characteristic | Value(s) |
|---|---|
| Mounting Location | Wall mounting Flat mounting Book mounting |
| Memory description | 8 GB RAM DDR3 internal not expandable) 512 KB MRAM internal |
| Free slots | 2 Internal SATA HDD/SSD with slide-in HMIYMADSDD1 to mount hot swap RAID with Intel Rapid Storage Technology 1 CFast 1 mSATA |
| Number of slots available for expansion | 2 mini PCIe |
| Display resolution | 3200 x 2000 pixels at 60 Hz |
| Watchdog timer | 1â¦255 ms |
| Electrical connection | Screw connector, connector type: pin, 1 way, circuit application: ground - location: bottom Connector, connector type: SMA, 3 ways - location: top |
| [Us] rated supply voltage | 24 V DC power supply 100...240 V AC power supply |
| Supply voltage limits | 18â¦36 V |
| Control type | ON/OFF button |
| Main type | Performance |
| Number of slots | 2 slot(s) for mini PCI Express full-size |
| Type of cooling | Fanless Fan required to mount PCI/PCIe cards above 3 W |
| Inrush current | 8.9 A |
| Width | 10.0000000000 in (254 mm) |
| Height | 8.1 in (207 mm) |
| Product Weight | 6.8 lb(US) (3.1 kg) |